ABC-14-R [COOPER]
Fast-acting, ceramic tube Optional axial leads available; 作用迅速,陶瓷管可选轴向引线可用型号: | ABC-14-R |
厂家: | COOPER BUSSMANN, INC. |
描述: | Fast-acting, ceramic tube Optional axial leads available |
文件: | 总2页 (文件大小:210K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
1
1
⁄4
” x 1 ⁄ ” Glass Tube Fuses
4
ABC Series, Fast-Acting, Ceramic Tube
Description
• Fast-acting, ceramic tube
• Optional axial leads available
• ⁄
4
1 ” x 1 1⁄
” (6.4 x 31.7mm) physical size
4
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating
100%
Opening Time
4 Hours Minimum
Dimensions - mm
Drawing Not to Scale
135%
60 Minutes maximum
120 Seconds Maximum
200%
Agency Information
• UL Listed Guide JDYX & File E19180
• UL Recognition Guide JDYX2 & File E19180
• CSA Certification: Class No: 1422-01 & 1422-30,
File 53787
Environmental Data
• Shock: 1⁄
A - 30A – MIL-STD-202, Method 213,
4
Test Condition J
• Vibration: 1⁄
A - 30A – MIL-STD-202, Method 204,
4
Test Condition C (Except 5g, 500Hz)
Ordering
• Specify packaging, product and option code
Specifications
Voltage
Ratings
Vac Interrupting
Ratings* (amps)
Vdc Interrupting
Ratings (amps)
Typical
DC Cold
Resistance (Ω)**
2.950
Typical
Pre-Arc
I2t AC†
0.0020
0.0390
0.1450
0.4310
1.1630
2.1670
4.4670
6.55
22.28
32.83
58
109.33
116.5
208.8
133.3
200.2
400
Typical
Voltage
Drop (V)‡
0.35
0.41
0.32
0.3
0.28
0.31
0.23
0.14
0.17
0.22
0.19
0.17
0.19
0.15
0.1
Part
Number
Agency Approvals
UL UR CSA
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Vdc
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
–
250
35
35
35
35
125
125
75
1
ABC- ⁄
4
-R
2
-R
4
-R
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
1000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
ABC-1⁄
0.587
0.300
0.1950
0.131
0.0890
0.061
0.047
0.031
0.026
0.021
0.016
0.014
0.011
0.0068
0.00553
0.00465
0.00366
0.0028
0.002225
3
ABC- ⁄
ABC-1-R
1
ABC-1- ⁄
ABC-2-R
ABC-2-1⁄
ABC-3-R
ABC-4-R
ABC-5-R
ABC-6-R
ABC-7-R
ABC-8-R
ABC-10-R
ABC-12-R
ABC-15-R
ABC-18-R
ABC-20-R
ABC-25-R
ABC-30-R
2
-R
-R
100
100
100
100
200
200
200
200
200
200
750
750
400
400
200
200
2
0.1
0.1
0.1
0.09
0.09
X
X
X
X
125
125
125
1000
1000
1000
10,000
400
400
–
1000
1000
550.8
839.3
1429
‡‡
X
X‡‡
* Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85% - 95% power factor on AC. The
interrupting ratings for 25A and 30A were measured at 89% power factor on AC.
** Typical DC cold resistance measured at <10% of rated current.
† Typical melting I2t measured at listed interrupting rating and rated voltage.
‡ Typical voltage drop measured at 25°C 3°C ambient temperature at rated current.
‡‡ CSA approvals for 25A and 30A are at 125Vac - IR 1000A and 125Vdc - IR 400A (IR 1000A at 75Vdc)
0613 BU-SB13635
Page 1 of 2
Data Sheet 2000
Time-Current Curves
1
3
15
18
12
25
20
30
10
5
8
Current in Amps
PACKAGING CODE
Packaging Code
Description
BK
100 pieces of fuses packed into a cardboard carton
1000 pieces of fuses packed into a cardboard carton
8000 pieces of fuses packed into a cardboard carton
BK1
BK8
OPTION CODE
Option Code
V
Description
Axial leads - copper tinned wire with nickel plated brass overcaps
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of
this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information
that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any
products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any
technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
©2013 Cooper Bussmann
www.cooperbussmann.com
0613 BU-SB13635
Page 2 of 2
Data Sheet 2000
相关型号:
ABC-2-1/2-R
Electric Fuse, Fast Blow, 2.5A, 250VAC, 125VDC, 100A (IR), Inline/holder, ROHS COMPLIANT
COOPER
©2020 ICPDF网 联系我们和版权申明