FRS-R-1/8 [COOPER]

Fusetron™ 600 V Class RK5, FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses;
FRS-R-1/8
型号: FRS-R-1/8
厂家: COOPER BUSSMANN, INC.    COOPER BUSSMANN, INC.
描述:

Fusetron™ 600 V Class RK5, FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses

电路保护
文件: 总3页 (文件大小:339K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
BUSSMANN  
Effective May 2016  
Supersedes August 2013  
Technical Data 1017  
SERIES  
Fusetron™ 600 V Class RK5, FRS-R — 600 Vac/300 Vdc,  
1/10-60 A, dual element, time-delay fuses  
•ꢀ  
Dual-element fuses can be applied in circuits  
Catalog symbol:  
subject to temporary motor overloads  
•ꢀ  
FRS-R-(amp) (non-indicating)  
FRS-R-(amp)ID (indicating)  
and surge currents to provide both high  
performance short-circuit and overload  
protection  
•ꢀ  
•ꢀ  
•ꢀ  
Offers a 10-second time delay at 5 times the  
rated current  
Description:  
•ꢀ  
Advanced protection, energy efficient  
The time-delay feature makes it possible  
to use fuse amp ratings that are much  
smaller than those of non-time delay  
fuses. Considerable cost savings occur by  
permitting the use of smaller size switches,  
panels, and fuses themselves.  
Class RK5 dual element, current-limiting,  
time-delay fuses with optional open fuse  
indication on select ratings  
•ꢀ  
Time-delay – 10 second (minimum) at 500%  
of rated current  
•ꢀ  
•ꢀ  
Provides current limitation to help protect  
downstream components from high fault  
currents.  
Specifications:  
Ratings  
Gives motor running back-up protection to  
motors without extra costs.  
•ꢀ  
Volts  
•ꢀ 600 Vac, 300 Vdc (1/10-30 A)  
•ꢀ 600 Vac, 250 Vdc (35-60 A)  
Dimensions - in:  
•ꢀ  
Amps — 1/10-60 A  
•ꢀ  
Interrupting rating  
•ꢀ 200 kA Vac RMS Sym  
•ꢀ 20 kA Vdc  
Catalog numbers (amps) — Non-indictaing fuses  
Agency information:  
FRS-R-1/10  
FRS-R-1/8  
FRS-R-1 8/10  
FRS-R-2  
FRS-R-8*  
FRS-R-9*  
FRS-R-10*  
FRS-R-12*  
FRS-R-15*  
FRS-R-17 1/2*  
FRS-R-20*  
FRS-R-25*  
FRS-R-30*  
FRS-R-35*  
FRS-R-40*  
FRS-R-45*  
FRS-R-50*  
FRS-R-60*  
CE, UL® Listed, Std. 248-12, Class RK5, Guide  
JDDZ, File E4273  
•ꢀ  
FRS-R-15/100  
FRS-R-2/10  
FRS-R-1/4  
FRS-R-2 1/4  
FRS-R-2 1/2  
FRS-R-2 8/10  
FRS-R-3  
CSA® Certified, C22.2 No. 248.12, Class  
1422-02, File 53787  
•ꢀ  
FRS-R-3/10  
FRS-R-4/10  
FRS-R-1/2  
•ꢀ  
CE  
FRS-R-3 2/10  
FRS-R-3 1/2  
FRS-R-4  
Features:  
FRS-R-6/10  
FRS-R-8/10  
FRS-R-1  
•ꢀ  
Dual-element feature provides the best  
FRS-R-4 1/2  
FRS-R-5  
time-delay performance, allowing closer  
sizing and superior protection of motors and  
transformers  
FRS-R-1 1/8  
FRS-R-1 1/4  
FRS-R-1 4/10  
FRS-R-1 1/2  
FRS-R-1 6/10  
FRS-R-5 6/10  
FRS-R-6*  
•ꢀ  
Closer sizing allows for smaller fuses and  
less costly switches  
FRS-R-6 1/4*  
FRS-R-7*  
•ꢀ  
Class RK5 fuses with a 200 kA interrupting  
rating for use in a broad range of  
applications  
FRS-R-7 1/2*  
* Open fuse indication available by inserting the sufix  
“ID.” E.g., FRS-R-15ID.  
•ꢀ  
Provides motor overload, ground fault, and  
short-circuit protection  
•ꢀ  
Helps protect motors against burnout from  
overloads and single-phasing when sized  
properly  
Technical Data1017  
Effective May 2016  
Fusetron™ 600 V class RK5 FRS-R — 600 Vac/  
300 Vdc, 1⁄10-60 A, dual element, time-delay fuses  
For additional information on the R600, 600 volt fuse blocks, see  
data sheet No. 1111.  
Carton quantity:  
Amp rating  
Carton qty.  
10  
1/10-60  
Time-current curves–average melt  
10 to 60 amps  
Recommended fuse blocks  
Fuse amps  
0-30  
1-Pole  
2-Pole  
3-Pole  
Amp rating  
RM60030-1  
RM60060-1  
RM60030-2  
RM60060-2  
RM60030-3  
RM60060-3  
35-60  
Fuse reducers for class R fuses  
Equipment  
fuse clips  
Desired fuse  
(case) size  
Catalog number  
(pairs) 600V  
60A  
30A  
30A  
60A  
60A  
No. 663-R  
No. 216-R  
No. 616-R  
No. 626-R  
100A  
200A  
For additional information on class R fuse reducers, see data  
sheet No. 1118.  
Time-current curves–average melt  
1/10 to 8 amps  
Amp rating  
Current in amps  
Current in amps  
2
Eaton.com/bussmannseries  
Technical Data1017  
Effective May 2016  
Fusetron™ 600 V Class RK5 FRS-R — 600 Vac/  
300 Vdc, 1⁄10-60 A, dual element, time-delay fuses  
Current-limitation curves  
Current-limiting effects  
B
Prosp.  
S.C.C.  
Let-through current  
(apparent RMS symmetrical vs. fuse rating)  
400000  
300000  
30A  
60A  
200000  
5000  
1000  
1000  
1000  
2000  
2000  
2000  
2000  
2000  
2000  
2000  
3000  
3000  
3000  
3000  
3000  
4000  
1000  
2000  
2000  
2000  
2000  
3000  
3000  
3000  
3000  
3000  
4000  
4000  
4000  
4000  
5000  
6000  
10,000  
15,000  
20,000  
25,000  
30,000  
35,000  
40,000  
50,000  
60,000  
70,000  
80,000  
90,000  
100,000  
150,000  
200,000  
100000  
90000  
80000  
70000  
60000  
50000  
40000  
30000  
20000  
60A  
30A  
10000  
9000  
8000  
7000  
6000  
5000  
4000  
3000  
A
2000  
1000  
RMS Stmmetrical current in amps  
A-B = asymmetrical available peak (2.3 x sym RMS amps)  
The only controlled copy of this Data Sheet is the electronic read-only version located on the Eaton Network Drive. All other copies of this  
document are by definition uncontrolled.This bulletin is intended to clearly present comprehensive product data and provide technical  
information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction  
of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice,  
any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible  
applications.  
Eaton  
1000 Eaton Boulevard  
Cleveland, OH 44122  
United States  
For Eatons Bussmann series  
product information,  
call 1-855-287-7626 or visit:  
Eaton.com/bussmannseries  
Eaton.com  
Bussmann Division  
114 Old State Road  
Ellisville, MO 63021  
United States  
Eaton, Bussmann and Fusetron are  
valuable trademarks of Eaton in the US  
and other countries.You are not permitted  
to use the Eaton trademarks without prior  
written consent of Eaton.  
Eaton.com/bussmannseries  
Follow us on social media to get the  
latest product and support information.  
© 2016 Eaton  
All Rights Reserved  
Printed in USA  
CSA is a registered trademark of the  
Canadian Standards Group.  
Publication No. 1017 – BU-MC16054  
May 2016  
UL is a registered trademark of the  
Underwriters Laboratories, Inc.  
3
Eaton.com/bussmannseries  

相关型号:

FRS-R-10

Electric Fuse, Time Delay Blow, 10A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

FRS-R-10

Fusetron™ 600 V Class RK5 FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses
EATON

FRS-R-10*

Fusetron™ 600 V Class RK5, FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses
COOPER

FRS-R-100

Electric Fuse, Time Delay Blow, 100A, 600VAC, 300VDC, 200000A (IR), Inline/holder
COOPER

FRS-R-10ID

Electric Fuse, Time Delay Blow, 10A, 600VAC, 250VDC, 200000A (IR), Inline/holder
COOPER

FRS-R-11/2

Fusetron™ 600 V Class RK5, FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses
COOPER

FRS-R-11/2

Fusetron™ 600 V Class RK5 FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses
EATON

FRS-R-11/4

Fusetron™ 600 V Class RK5, FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses
COOPER

FRS-R-11/4

Fusetron™ 600 V Class RK5 FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses
EATON

FRS-R-11/8

Fusetron™ 600 V Class RK5, FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses
COOPER

FRS-R-11/8

Fusetron™ 600 V Class RK5 FRS-R — 600 Vac/300 Vdc, 1/10-60 A, dual element, time-delay fuses
EATON

FRS-R-110

Electric Fuse, Time Delay Blow, 110A, 600VAC, 300VDC, 200000A (IR), Inline/holder,
COOPER