LFA100F-12-GR2 [COSEL]
AC-DC Regulated Power Supply Module,;型号: | LFA100F-12-GR2 |
厂家: | COSEL CO., LTD. |
描述: | AC-DC Regulated Power Supply Module, |
文件: | 总18页 (文件大小:665K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
10
F
-O -O
5 6
LFA10F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
Recommended EMI/EMC Filter
NAC-04-472
R
LFA
C: with Coating
G: Low leakage current
J1: VH(J.S.T.)connector type
S : with Chassis
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
SN: with Chassis & cover
Y: with Potentiometer
*
The EMI/EMC Filter is recommended
to connect with several devices.
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
LFA10F-3R3-Y
6.6
LFA10F-5
10
LFA10F-12
10.8
LFA10F-15
10.5
LFA10F-24
12
MAX OUTPUT WATTAGE[W]
DC OUTPUT
3.3V 2A
5V 2A
12V 0.9A
15V 0.7A
24V 0.5A
SPECIFICATIONS
MODEL
LFA10F-3R3-Y
LFA10F-5
LFA10F-12
LFA10F-15
LFA10F-24
*3
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 0.18typ (Io=100%)
0.26typ (Io=100%)
0.16typ (Io=100%)
CURRENT[A]
ACIN 200V 0.11typ (Io=100%)
50 / 60 (47 - 440)
FREQUENCY[Hz]
INPUT
ACIN 100V 68.0typ
74.0typ
76.0typ
76.5typ
79.0typ
77.5typ
80.0typ
79.5typ
83.0typ
EFFICIENCY[%]
ACIN 200V 68.5typ
ACIN 100V 15typ (Io=100%)
ACIN 200V 30typ (Io=100%)
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
CURRENT[A]
2.0
2.0
0.9
0.7
0.5
*
5
5
20max
40max
20max
40max
80max
140max
160max
120max
160max
240max
50max
60max
20max
48max
100max
120max
160max
240max
150max
180max
300max
120max
150max
48max
60max
120max
120max
160max
240max
150max
180max
300max
150max
180max
60max
96max
150max
120max
160max
280max
150max
180max
320max
240max
290max
96max
LINE REGULATION[mV]
LOAD REGULATION[mV]
*
0 to +50C 80max
-10 - 0C 140max
Io=0 - 35% 190max
0 to +50C 120max
-10 - 0C 160max
Io=0 - 35% 240max
0 to +50C 50max
-10 to +50C 60max
RIPPLE[mVp-p]
*1
RIPPLE NOISE[mVp-p]
OUTPUT
*1
TEMPERATURE REGULATION[mV]
*2
20max
DRIFT[mV]
START-UP TIME[ms]
200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
2.85 to 3.63
3.30 to 3.40
Fixed (“Y”option is available for adjusting output voltage between ±10%)
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
27.60 to 33.60
Works over 105% of rating and recovers automatically
4.00 to 5.25
Not provided
Not provided
Not provided
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
PROTECTION
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ISOLATION
INPUT-FG
OUTPUT-FG
*3
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*6
*4
(Not built-in to active filter)
Complies with IEC61000-3-2 (Class A)
50X22X73.5mm [1.97X0.87X2.89 inches] (WXHXD) / 55g max (with chassis & cover : 150g max)
OTHERS
*3
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1
This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
factor Io=0-35% is different.
Please contact us for details.
Please refer to the Instruction Manual 1.7.
Drift is the change in DC output for an eight hour period after
a half-hour warm-up at 25C, with the input voltage held
constant at the rated input/output.
*5
*6
*
Please contact us about dynamic load and input response.
Please contact us about another class.
*2
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
A circuit reducing standby power is built in this unit.
Therefore, the internal switch element is intermittent
operated, and the Ripple/Ripple Noise specification in load
*
*3
*4
Derating is required.
*
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse
load.
When two or more units are operating it may not comply with
the IEC61000-3-2.
*
LFA-2
LFA10F
Block diagram
FUSE
AC250V
2A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
AC IN
85 264V
NOISE
FILTER
LFA
FG
TRANSFORMER
RECTIFIER
AND
CONTROL
INVERTER
DC OUT
FILTER
CURRENT
SENSING
Photocoupler
Photocoupler
CONTROL
OVER VOLTAGE
PROTECTION
External view
Standard type
Chassis and cover type
FG
4.6
[0.18]
0.5
f3.5
83.5
[3.29]
4-M3
5
[0.2]
Mounting Hole
CN2
CN1
5
FG
1
2
Output(-)
Output(+)
3
Input(N)
Input(L)
Voltage adjust
(LFA10F-3R3-Y or optional)
1
Output(-)
Output(+)
CN1
CN2
1
2
5
FG
Input(N)
Input(L)
2-
f3.5
3
1
Mounting Hole
0.5
63.5
[2.5]
5
[0.2]
Name plate
73.5
[2.89]
Point A
Point B
93.5
[3.68]
0.5
f3.5
5
83.5
[3.29]
[0.2]
¶1
PCB t=1.6
¶1 Surface mount device
2-M3
Mounting Hole
¶
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
¶
¶
<PIN CONNECTION>
CN1
CN2
¶ Tolerance : 1 [ 0.04]
¶ Weight : 55g max (with chassis & cover : 150g max)
¶ PCB material / thickness : CEM3 / 1.6mm
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
I/O Connector
Mating connector
Terminal
1123721-1
1318912-1
1123721-1
1318912-1
Pin No.
Input
AC(L)
Pin No. Output
Chain
Loose
Chain
Loose
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5
CN2 1-1123723-2 1-1123722-2
1
2
-V
AC(N)
FG
+V
¶
Mounting torque (Mounting hole of chassis) : 0.6N-m (6.3kgf-cm) max
(Mfr:Tyco Electronics)
¶
I/O Connector is Mfr. Tyco Electronics
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
¶
LFA-3
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
15
F
-O -O
5 6
LFA15F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
Recommended EMI/EMC Filter
NAC-04-472
R
LFA
C: with Coating
G: Low leakage current
J1: VH(J.S.T.)connector type
S : with Chassis
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
SN: with Chassis & cover
Y: with Potentiometer
*
The EMI/EMC Filter is recommended
to connect with several devices.
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
LFA15F-3R3-Y
9.9
LFA15F-5
15
LFA15F-12
15.6
LFA15F-15
15
LFA15F-24
16.8
MAX OUTPUT WATTAGE[W]
DC OUTPUT
3.3V 3A
5V 3A
12V 1.3A
15V 1A
24V 0.7A
SPECIFICATIONS
MODEL
LFA15F-3R3-Y
LFA15F-5
LFA15F-12
LFA15F-15
LFA15F-24
*3
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 0.24typ (Io=100%)
0.35typ (Io=100%)
0.20typ (Io=100%)
CURRENT[A]
ACIN 200V 0.15typ (Io=100%)
50 / 60 (47 - 440)
FREQUENCY[Hz]
INPUT
ACIN 100V 68.0typ
73.0typ
76.0typ
76.0typ
78.5typ
77.0typ
80.0typ
78.0typ
81.5typ
EFFICIENCY[%]
ACIN 200V 69.0typ
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
CURRENT[A]
3.0
3.0
1.3
1.0
0.7
*
5
5
20max
40max
20max
40max
80max
140max
160max
120max
160max
240max
50max
60max
20max
48max
100max
120max
160max
240max
150max
180max
300max
120max
150max
48max
60max
120max
120max
160max
240max
150max
180max
300max
150max
180max
60max
96max
150max
120max
160max
280max
150max
180max
320max
240max
290max
96max
LINE REGULATION[mV]
LOAD REGULATION[mV]
*
0 to +50C 80max
-10 - 0C 140max
Io=0 - 35% 190max
0 to +50C 120max
-10 - 0C 160max
Io=0 - 35% 240max
0 to +50C 50max
-10 to +50C 60max
RIPPLE[mVp-p]
*1
RIPPLE NOISE[mVp-p]
OUTPUT
*1
TEMPERATURE REGULATION[mV]
*2
20max
DRIFT[mV]
START-UP TIME[ms]
200typ (ACIN 100V, Io=100%) *Start-up time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
2.85 to 3.63
3.30 to 3.40
Fixed (“Y”option is available for adjusting output voltage between ±10%)
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
27.60 to 33.60
Works over 105% of rating and recovers automatically
4.00 to 5.25
Not provided
Not provided
Not provided
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
PROTECTION
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ISOLATION
INPUT-FG
OUTPUT-FG
*3
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*6
*4
(Not built-in to active filter)
Complies with IEC61000-3-2 (Class A)
50X22X87.5mm [1.97X0.87X3.44 inches] (WXHXD) / 80g max (with chassis & cover : 190g max)
OTHERS
*3
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1
This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
factor Io=0-35% is different.
Please contact us for details.
Please refer to the Instruction Manual 1.7.
Drift is the change in DC output for an eight hour period after
a half-hour warm-up at 25C, with the input voltage held
constant at the rated input/output.
*5
*6
*
Please contact us about dynamic load and input response.
Please contact us about another class.
*2
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
A circuit reducing standby power is built in this unit.
Therefore, the internal switch element is intermittent
operated, and the Ripple/Ripple Noise specification in load
*
*3
*4
Derating is required.
*
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse
load.
When two or more units are operating it may not comply with
the IEC61000-3-2.
*
LFA-4
LFA15F
Block diagram
FUSE
AC250V
2.5A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
AC IN
85 264V
NOISE
FILTER
LFA
FG
TRANSFORMER
RECTIFIER
AND
CONTROL
INVERTER
DC OUT
FILTER
CURRENT
SENSING
Photocoupler
Photocoupler
CONTROL
OVER VOLTAGE
PROTECTION
External view
Standard type
Chassis and cover type
FG
4.4
[0.17]
0.5
97.5
[3.84]
5
[0.2]
f3.5
4-M3
Mounting Hole
CN2
CN1
5
1
2
Output(-)
Output(+)
FG
3
Input(N)
Output(-)
Output(+)
CN1
5
CN2
1
2
Voltage adjust
(LFA15F-3R3-Y or optional)
1
Input(L)
FG
Input(N)
Input(L)
3
1
2-
f3.5
0.5
Mounting Hole
77.5
[3.05]
87.5
[3.44]
5
[0.2]
Name plate
107.5
[4.23]
97.5
[3.84]
Point A
Point B
f3.5
0.5
5
[0.2]
PCB t=1.6
¶1
2-M3
Mounting Hole
¶1 Surface mount device
¶
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
¶
¶
<PIN CONNECTION>
CN1
CN2
¶ Tolerance : 1 [ 0.04]
¶ Weight : 80g max (with chassis & cover : 190g max)
¶ PCB material / thickness : CEM3 / 1.6mm
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
I/O Connector
Mating connector
Terminal
1123721-1
1318912-1
1123721-1
1318912-1
Pin No.
Input
AC(L)
Pin No. Output
Chain
Loose
Chain
Loose
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5
CN2 1-1123723-2 1-1123722-2
1
2
-V
AC(N)
FG
+V
¶
Mounting torque (Mounting hole of chassis) : 0.6N
-
m (6.3kgf
-
cm) max
(Mfr:Tyco Electronics)
¶
I/O Connector is Mfr. Tyco Electronics
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
¶
LFA-5
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
30
F
-O -O
5 6
LFA30F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
Recommended EMI/EMC Filter
NAC-04-472
R
LFA
C: with Coating
G: Low leakage current
J1: VH(J.S.T.)connector type
S : with Chassis
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
SN: with Chassis & cover
Y: with Potentiometer
*
The EMI/EMC Filter is recommended
to connect with several devices.
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
LFA30F-3R3-Y
19.8
LFA30F-5
30.0
LFA30F-12
30.0
LFA30F-15
30.0
LFA30F-24
31.2
MAX OUTPUT WATTAGE[W]
DC OUTPUT
3.3V 6A
5V 6A
12V 2.5A
15V 2A
24V 1.3A
SPECIFICATIONS
MODEL
LFA30F-3R3-Y
LFA30F-5
LFA30F-12
LFA30F-15
LFA30F-24
*3
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 0.50typ (Io=100%)
0.65typ (Io=100%)
0.35typ (Io=100%)
CURRENT[A]
ACIN 200V 0.30typ (Io=100%)
50 / 60 (47 - 440)
ACIN 100V 73typ
FREQUENCY[Hz]
INPUT
76typ
79typ
79typ
81typ
81typ
83typ
82typ
84typ
EFFICIENCY[%]
ACIN 200V 75typ
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
CURRENT[A]
6.0
6.0
2.5
2.0
1.3
*5
*5
*1
20max
40max
80max
140max
120max
160max
20max
40max
80max
140max
120max
160max
50max
60max
20max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C
RIPPLE[mVp-p]
*1
*1
-10 - 0C
0 to +50C
RIPPLE NOISE[mVp-p]
*1
OUTPUT
-10 - 0C
0 to +50C 50max
TEMPERATURE REGULATION[mV]
-10 to +50
C
60max
2
20max
*
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
150typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 to 3.63
3.30 to 3.40
Fixed (“Y”option is available for adjusting output voltage between ±10%)
OUTPUT VOLTAGE SETTING[V]
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
Not provided
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ISOLATION INPUT-FG
OUTPUT-FG
*3
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*6
*4
(Not built-in to active filter)
Complies with IEC61000-3-2 (Class A)
50X26.5X105mm [1.97X1.04X4.13 inches] (WXHXD) / 130g max (with chassis & cover : 260g max)
OTHERS
*3
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm
from output terminal.
*4 When two or more units are operating it may not comply with the IEC61000-3-2.
Please contact us for details.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:
RM103).
*5 Please contact us about dynamic load and input response.
*6 Please contact us about another class.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at
25C, with the input voltage held constant at the rated input/output.
*3 Derating is required.
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse load.
LFA-6
LFA30F
Block diagram
FUSE
AC250V
3.15A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
AC IN
85 264V
NOISE
FILTER
LFA
FG
TRANSFORMER
RECTIFIER
AND
CONTROL
INVERTER
DC OUT
FILTER
CURRENT
SENSING
Photocoupler
Photocoupler
CONTROL
OVER VOLTAGE
PROTECTION
External view
Standard type
Chassis and cover type
3-
f3.5
4.5
[0.18]
Name plate
FG
Mounting Hole
0.5
5
[0.2]
f3.5
4-M3
115
[4.53]
Mounting Hole
CN2
5
FG
1
2
3
4
Output(-)
Output(+)
3
Input(N)
Input(L)
CN2
1
5
3
FG
1
2
3
4
Output(-)
CN1
Input(N)
Input(L)
Output(+)
1
CN1
4
[0.16]
Voltage adjust
(LFA30F-3R3-Y or optional)
0.5
5
[0.2]
95
[3.74]
105
Mounting Hole
[4.13]
Point A
Point B
125
[4.92]
0.5
f3.5
115
[4.53]
5
[0.2]
PCB t=1.6
¶1
2-M3
Mounting Hole
¶1 Surface mount device
¶ 4 Mounting holes are existing.
¶
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
¶
¶
<PIN CONNECTION>
CN1
CN2
I/O Connector
Mating connector
Terminal
1123721-1
1318912-1
1123721-1
1318912-1
Pin No.
Input
AC(L)
Pin No. Output
¶ Tolerance : 1 [ 0.04]
¶ Weight: 130g max (with chassis & cover : 260g max)
¶ PCB material / thickness : CEM3 / 1.6mm
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
Chain
Loose
Chain
Loose
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5
CN2 1-1123723-4 1-1123722-4
1, 2
3, 4
-V
AC(N)
FG
+V
(Mfr:Tyco Electronics)
¶
Mounting torque (Mounting hole of chassis) : 0.6N
-
m (6.3kgf
-
cm) max
¶
I/O Connector is Mfr. Tyco Electronics
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
¶
¶ Keep drawing current per pin below 5A for CN2.
LFA-7
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
50
F
-O -O
5 6
LFA50F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
Recommended EMI/EMC Filter
NAC-04-472
R
LFA
C: with Coating
G: Low leakage current
J1: VH(J.S.T.)connector type
S : with Chassis
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
SN: with Chassis & cover
Y: with Potentiometer
*
The EMI/EMC Filter is recommended
to connect with several devices.
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
LFA50F-3R3-Y LFA50F-5
LFA50F-12
51.6
LFA50F-15
52.5
LFA50F-24
50.4
LFA50F-36
50.4
LFA50F-48
52.8
MAX OUTPUT WATTAGE[W]
DC OUTPUT
33
50
3.3V 10A
5V 10A
12V 4.3A
15V 3.5A
24V 2.1A
36V 1.4A
48V 1.1A
SPECIFICATIONS
MODEL
LFA50F-3R3-Y LFA50F-5
LFA50F-12
LFA50F-15
LFA50F-24
LFA50F-36
LFA50F-48
*3
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 0.47typ (Io=100%) 0.67typ (Io=100%)
ACIN 200V 0.27typ (Io=100%) 0.36typ (Io=100%)
50 / 60 (47 - 63)
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V 73.5typ
ACIN 200V 74.0typ
ACIN 100V 0.96typ
ACIN 200V 0.83typ
77.5typ
79.0typ
0.97typ
0.90typ
80.0typ
81.5typ
80.5typ
81.5typ
81.5typ
83.0typ
82.0typ
83.5typ
81.0typ
82.5typ
EFFICIENCY[%]
INPUT
POWER FACTOR (Io=100%)
INRUSH CURRENT[A]
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
36
48
CURRENT[A]
10.0
10.0
4.3
3.5
2.1
1.4
1.1
*4
*4
*1
20max
40max
80max
140max
120max
160max
20max
40max
80max
140max
120max
160max
50max
60max
20max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
144max
240max
150max
200max
250max
300max
360max
450max
144max
192max
240max
150max
200max
250max
300max
480max
600max
192max
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C
RIPPLE[mVp-p]
*1
-10 - 0C
*1
0 to +50C
RIPPLE NOISE[mVp-p]
*1
OUTPUT
-10 - 0C
0 to +50C 50max
TEMPERATURE REGULATION[mV]
-10 to +50
C
60max
2
20max
*
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 to 3.63
3.30 to 3.40
Fixed (“Y”option is available for adjusting output voltage between ±10%)
OUTPUT VOLTAGE SETTING[V]
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
34.50 to 37.50
46.00 to 50.00
55.20 to 67.20
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00
27.60 to 33.60
41.40 to 50.40
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
Not provided
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ISOLATION INPUT-FG
OUTPUT-FG
*3
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*5
Complies with IEC61000-3-2 (Class A)
50X26.5X132mm [1.97X1.04X5.20 inches] (WXHXD) / 165g max (with chassis & cover : 325g max)
OTHERS
*3
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm
from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:
RM103).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at
25C, with the input voltage held constant at the rated input/output.
*3 Derating is required.
*4 Please contact us about dynamic load and input response.
*5 Please contact us about another class.
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse load.
LFA-8
LFA50F
Block diagram
FUSE
250V2.5A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
AC IN 85 264V
RECTIFIER
LFA
FG
TRANSFORMER
RECTIFIER
AND
CONTROL
INVERTER
DC OUT
FILTER
BOOSTER
CURRENT
INDUCTOR
SENSING
RECTIFIER
AND
CURRENT
SENSING
FILTER
Photocoupler
Photocoupler
INVERTER
CONTROL
OVER VOLTAGE
PROTECTION
CONTROL
External view
Standard type
Voltage adjust
Chassis and cover type
4-M3
2-f3.5
0.5
3-
f3.5
150
6
[0.24]
4.9
[0.19]
Name plate
FG
(LFA50F-3R3-Y or optional)
[5.91]
Mounting Hole
Mounting Hole
5
FG
5
3
FG
Input(N)
Input(L)
3
Input(N)
Input(L)
1
2
3
4
Output(-)
Output(+)
CN2
1
1
2
3
4
1
CN1
Output(-)
Output(+)
CN1
CN2
4
Point A
Point B
[0.16]
Mounting Hole
0.5
5
122
[4.8]
132
[0.2]
162
[6.38]
[5.2]
0.5
f3.5
150
[5.91]
6
[0.24]
PCB t=1.6
2-M3
¶1
Mounting Hole
¶1 Surface mount device
¶ 4 Mounting holes are existing.
¶
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
¶
¶
<PIN CONNECTION>
CN1
CN2
¶ Tolerance : 1 [ 0.04]
¶ Weight : 165g max (with chassis & cover : 325g max)
¶ PCB material / thickness : CEM3 / 1.6mm
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
I/O Connector
Mating connector
Terminal
1123721-1
1318912-1
1123721-1
1318912-1
Pin No.
Input
AC(L)
Pin No. Output
Chain
Loose
Chain
Loose
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5
CN2 1-1123723-4 1-1123722-4
1, 2
3, 4
-V
AC(N)
FG
+V
¶
Mounting torque (Mounting hole of chassis) : 0.6N
-
m (6.3kgf
-
cm) max
(Mfr:Tyco Electronics)
¶
I/O Connector is Mfr. Tyco Electronics
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
¶
¶ Keep drawing current per pin below 5A for CN2.
LFA-9
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
75
F
-O -O
5 6
LFA75F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
6Optional
Recommended EMI/EMC Filter
NAC-04-472
R
LFA
C: with Coating
G: Low leakage current
J1: VH(J.S.T.)connector type
S : with Chassis
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
SN: with Chassis & cover
Y: with Potentiometer
*
The EMI/EMC Filter is recommended
to connect with several devices.
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
LFA75F-3R3-Y LFA75F-5
LFA75F-12
75.6
LFA75F-15
75
LFA75F-24
76.8
LFA75F-36
75.6
LFA75F-48
76.8
MAX OUTPUT WATTAGE[W]
DC OUTPUT
49.5
75
3.3V 15A
5V 15A
12V 6.3A
15V 5A
24V 3.2A
36V 2.1A
48V 1.6A
SPECIFICATIONS
MODEL
LFA75F-3R3-Y LFA75F-5
LFA75F-12
LFA75F-15
LFA75F-24
LFA75F-36
LFA75F-48
*3
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 0.70typ (Io=100%) 1.00typ (Io=100%)
ACIN 200V 0.40typ (Io=100%) 0.50typ (Io=100%)
50 / 60 (47 - 63)
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V 73.5typ
ACIN 200V 75.0typ
ACIN 100V 0.96typ
ACIN 200V 0.83typ
78.0typ
80.0typ
0.97typ
0.90typ
81.5typ
83.0typ
81.5typ
83.0typ
82.5typ
84.5typ
82.5typ
84.5typ
82.5typ
84.5typ
EFFICIENCY[%]
INPUT
POWER FACTOR (Io=100%)
INRUSH CURRENT[A]
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
36
48
CURRENT[A]
15.0
15.0
6.3
5.0
3.2
2.1
1.6
*4
*4
*1
20max
40max
80max
140max
120max
160max
20max
40max
80max
140max
120max
160max
50max
60max
20max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
144max
240max
150max
200max
250max
300max
360max
450max
144max
192max
240max
150max
200max
250max
300max
480max
600max
192max
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50C
RIPPLE[mVp-p]
*1
-10 - 0C
*1
0 to +50C
RIPPLE NOISE[mVp-p]
*1
OUTPUT
-10 - 0C
0 to +50C 50max
TEMPERATURE REGULATION[mV]
-10 to +50
C
60max
2
20max
*
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 to 3.63
3.30 to 3.40
Fixed (“Y”option is available for adjusting output voltage between ±10%)
OUTPUT VOLTAGE SETTING[V]
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
34.50 to 37.50
46.00 to 50.00
55.20 to 67.20
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00
27.60 to 33.60
41.40 to 50.40
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
Not provided
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
ISOLATION INPUT-FG
OUTPUT-FG
*3
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*5
Complies with IEC61000-3-2 (Class A)
50X33.5X150mm [1.97X1.32X5.91 inches] (WXHXD) / 230g max (with chassis & cover : 440g max)
OTHERS
*3
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1 This is the value that measured on measuring board with capacitor of 22mF at 150mm
from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:
RM103).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at
25C, with the input voltage held constant at the rated input/output.
*3 Derating is required.
*4 Please contact us about dynamic load and input response.
*5 Please contact us about another class.
*
*
*
*
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse load.
LFA-10
LFA75F
Block diagram
FUSE
250V3.15A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
AC IN 85 264V
RECTIFIER
LFA
FG
TRANSFORMER
RECTIFIER
AND
CONTROL
INVERTER
DC OUT
FILTER
BOOSTER
INDUCTOR
CURRENT
SENSING
RECTIFIER
AND
FILTER
CURRENT
SENSING
Photocoupler
Photocoupler
INVERTER
CONTROL
OVER VOLTAGE
PROTECTION
CONTROL
External view
Standard type
Chassis and cover type
3-
f3.5
Voltage adjust
(LFA75F-3R3-Y or optional)
13
[0.51]
Name plate
FG
2-f4.5
0.5
4-M4
Mounting Hole
5.5
[0.22]
169
[6.65]
Mounting Hole
5
FG
CN2
CN2
1
5
3
FG
Input(N)
Input(L)
3
Input(N)
Input(L)
Output(-)
Output(+)
1
3
4
Output(-)
1
3
4
CN1
1
6
Output(+)
CN1
6
4
Point A
Point B
[0.16]
0.5
Mounting Hole
5
[0.2]
140
[5.51]
150
[5.91]
180
[7.09]
0.5
f4.5
169
[6.65]
5.5
[0.22]
2-M4
Mounting Hole
¶1
PCB t=1.6
¶1 Surface mount device
¶ 4 Mounting holes are existing.
¶
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
¶
¶
<PIN CONNECTION>
CN1
CN2
¶ Tolerance : 1 [ 0.04]
¶ Weight : 230g max (with chassis & cover : 440g max)
¶ PCB material / thickness : CEM3 / 1.6mm
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
I/O Connector
Mating connector
Terminal
1123721-1
1318912-1
1123721-1
1318912-1
Pin No.
Input
AC(L)
Pin No. Output
Chain
Loose
Chain
Loose
1
2
3
4
5
CN1 1-1123724-3 1-1123722-5
CN2 1-1123723-6 1-1123722-6
1 to 3
4 to 6
-V
AC(N)
FG
+V
¶
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max
(Mfr:Tyco Electronics)
¶
I/O Connector is Mfr. Tyco Electronics
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
¶
¶ Keep drawing current per pin below 5A for CN2.
LFA-11
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
100
F
-O -O
5 6
LFA100F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Recommended EMI/EMC Filter
NAC-04-472
R
LFA
*1
6Optional
C: with Coating
G: Low leakage current
H: with the function to be acceptable
to output peak current (only 24V)
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
J1: VH(J.S.T.)connector type
*
The EMI/EMC Filter is recommended
R: with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
to connect with several devices.
SN: with Chassis & cover
Y: with Potentiometer
Please refer to Instruction
manual 5.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL
LFA100F-3R3-Y LFA100F-5-Y LFA100F-12 LFA100F-15 LFA100F-24 LFA100F-24-H LFA100F-36 LFA100F-48
*5
*5
66
100
102
100.5
103.2
103.2 (129.6)
100.8
100.8
MAX OUTPUT WATTAGE[W]
DC OUTPUT
3.3V 20A
5V 20A
12V 8.5A
15V 6.7A
24V 4.3A
24V 4.3 (5.4)A 36V 2.8A
48V 2.1A
SPECIFICATIONS
MODEL
LFA100F-3R3-Y LFA100F-5-Y LFA100F-12 LFA100F-15 LFA100F-24 LFA100F-24-H LFA100F-36 LFA100F-48
*4
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 0.9typ (Io=100%)
ACIN 200V 0.5typ (Io=100%)
1.3typ (Io=100%)
0.7typ (Io=100%)
CURRENT[A]
FREQUENCY[Hz]
50 / 60 (47 - 63)
ACIN 100V 77.0typ
ACIN 200V 79.0typ
ACIN 100V 0.98typ
ACIN 200V 0.92typ
82.0typ
84.0typ
0.99typ
0.95typ
82.0typ
84.5typ
83.0typ
85.5typ
84.0typ
87.0typ
84.0typ
87.0typ
84.0typ
87.0typ
84.5typ
87.0typ
EFFICIENCY[%]
INPUT
POWER FACTOR (Io=100%)
INRUSH CURRENT[A]
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
24
36
48
*5
*7
*7
*2
20
20
8.5
6.7
4.3
4.3 (Peak 5.4)
96max
2.8
2.1
CURRENT[A]
20max
40max
80max
140max
120max
160max
20max
40max
80max
140max
120max
160max
50max
60max
20max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
144max
240max
150max
200max
250max
300max
360max
450max
144max
192max
240max
150max
200max
250max
300max
480max
600max
192max
LINE REGULATION[mV]
LOAD REGULATION[mV]
150max
240max
320max
300max
360max
240max
290max
96max
0 to +50C
RIPPLE[mVp-p]
*2
-10 - 0C
*2
0 to +50C
RIPPLE NOISE[mVp-p]
*2
OUTPUT
-10 - 0C
0 to +50C 50max
TEMPERATURE REGULATION[mV]
-10 to +50
C
60max
3
20max
*
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 to 3.63 4.50 to 5.50 Fixed (“Y”option is available for adjusting output voltage)
3.30 to 3.40 5.00 to 5.15 11.50 to 12.50 14.40 to 15.60
OUTPUT VOLTAGE SETTING[V]
23.00 to 25.00
23.00 to 25.00
34.50 to 37.50
46.00 to 50.00
55.20 to 67.20
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00
27.60 to 33.60
27.60 to 33.60
41.40 to 50.40
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
Not provided
Option (Refer to Instruction Manual)
.
*6
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)
INPUT-OUTPUT RC
INPUT-FG
ISOLATION
.
*6
*6
*4
OUTPUT RC-FG
OUTPUT-RC
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*8
Complies with IEC61000-3-2 (Class A)
62X33.5X155mm [2.44X1.32X6.10 inches] (WXHXD) / 280g max (with chassis & cover : 480g max)
OTHERS
*4
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1 Specification is changed at option, refer to Instruction Manual.
at the rated input/output.
*8 Please contact us about another class.
*2 This is the value that measured on measuring board with *4 Derating is required.
*
To meet the specifications. Do not operate over-loaded
condition.
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
*5 ( ) means peak current. There is a possibility that an internal
device is damaged when the specification is exceeded. Please *
Parallel operation is not possible.
contact us about the detail.
*
*
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of
pulse load.
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when Remote ON/OFF (optional) is added.
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.
LFA-12
LFA100F
Block diagram
FUSE
250V3.15A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
LFA
FG
Photocoupler
OPTION
CURRENT
SENSING
RC
E
EXTERNAL
SOURCE
Photocoupler
Photocoupler
BOOSTER
INDUCTOR
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
INVERTER
CONTROL
OVER VOLTAGE
PROTECTION
INVERTER
CONTROL
RECTIFIER
AND
TRANSFORMER
DC OUT
FILTER
External view
¶
External size of option is different from standard model.
Standard type
Chassis and cover type
173 0.5
[6.81]
6
[0.24]
4-M4
Mounting Hole
2-f4.5
Connector for
Remote ON/OFF
(Optional)
Name plate
3-f3.5
Mounting Hole
FG
1
2
1
2
CN4
CN2
Output(-)
FG
FG
5
5
3
CN2
1
1
3
Input(N)
Input(N)
Input(L)
Output(-)
1
1
4
5
Input(L)
4
5
CN1
CN1
Output(+)
Output(+)
8
8
4
Point A
Point B
[0.16]
16.5
[0.65]
Voltage adjust
(LFA100F-3R3-Y,LFA100F-5-Y or Optional)
Mounting Hole
185
[7.28]
173 0.5
5
[0.2]
145 0.5
[5.71]
155
6
f4.5
[6.81]
[0.24]
[6.1]
2-M4
Mounting Hole
PCB t=1.6
¶1
¶1 Surface mount device
¶ 4 Mounting holes are existing.
¶
The back side of P.C.B. of the power supply is assembled some
SMDs.
Connector type
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
<PIN CONNECTION>
¶
¶
CN4 Option (Mfr:J.S.T)
CN1
CN2
PIN No.
Contents
RC(+)
Pin No.
Input
Pin No. Output
1
2
AC(L)
1
2
3
4
5
1 to 4
5 to 8
-V
+V
I/O Connector
Mating connector
Terminal
1123721-1
1318912-1
1123721-1
1318912-1
RC(-)
Chain
Loose
Chain
Loose
AC(N)
CN1 1-1123724-3 1-1123722-5
CN2 1-1123723-8 1-1123722-8
Barrier strip type
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
FG
(Mfr:Tyco Electronics)
¶ Keep drawing current per pin below 5A for CN2.
¶ I/O Connector is Mfr. Tyco Electronics
¶ Option:-J1:VH(J.S.T) connector type.
BXH-001T-P0.6
or SXH-001T-P0.6
¶ Tolerance : 1 [ 0.04]
¶ Weight : 280g max (with chassis & cover : 480g max)
¶ PCB material : CEM3
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
¶
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max
LFA-13
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
150
F
-O -O
5 6
LFA150F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Recommended EMI/EMC Filter
NAC-04-472
R
LFA
*1
6Optional
C: with Coating
G: Low leakage current
H: with the function to be acceptable
to output peak current (only 24V)
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
J1: VH(J.S.T.)connector type
*
The EMI/EMC Filter is recommended
R: with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
to connect with several devices.
SN: with Chassis & cover
Y: with Potentiometer
Please refer to Instruction
manual 5.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL
LFA150F-3R3-Y LFA150F-5-Y LFA150F-12 LFA150F-15 LFA150F-24 LFA150F-24-H LFA150F-36 LFA150F-48
*5
*5
99
150
150
150
151.2
151.2 (189.6) 151.2
153.6
MAX OUTPUT WATTAGE[W]
DC OUTPUT
3.3V 30A
5V 30A
12V 12.5A
15V 10A
24V 6.3A
24V 6.3 (7.9)A 36V 4.2A
48V 3.2A
SPECIFICATIONS
MODEL
LFA150F-3R3-Y LFA150F-5-Y LFA150F-12 LFA150F-15 LFA150F-24 LFA150F-24-H LFA150F-36 LFA150F-48
*4
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 1.4typ
ACIN 200V 0.7typ
(
Io=100%)
Io=100%)
2.0typ (Io=100%)
1.0typ (Io=100%)
CURRENT[A]
(
FREQUENCY[Hz]
50 / 60 (47 - 63)
ACIN 100V 80.0typ
82.5typ
85.5typ
0.99typ
0.95typ
82.5typ
85.0typ
84.0typ
86.5typ
85.0typ
87.5typ
85.0typ
87.5typ
85.0typ
87.5typ
85.5typ
88.0typ
EFFICIENCY[%]
INPUT
ACIN 200V 82.0typ
ACIN 100V 0.98typ
ACIN 200V 0.92typ
POWER FACTOR (Io=100%)
INRUSH CURRENT[A]
ACIN 100V 15typ (Io=100%) (At cold start) (Ta=25C)
ACIN 200V 30typ (Io=100%) (At cold start) (Ta=25C)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
24
36
48
*5
*7
*7
*2
30
30
12.5
10
6.3
6.3 (Peak 7.9)
96max
4.2
3.2
CURRENT[A]
20max
40max
80max
140max
120max
160max
20max
40max
80max
140max
120max
160max
50max
60max
20max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
144max
240max
150max
200max
250max
300max
360max
450max
144max
192max
240max
150max
200max
250max
300max
480max
600max
192max
LINE REGULATION[mV]
LOAD REGULATION[mV]
150max
240max
320max
300max
360max
240max
290max
96max
0 to +40C
RIPPLE[mVp-p]
*2
*2
-10 - 0C
0 to +40C
RIPPLE NOISE[mVp-p]
*2
OUTPUT
-10 - 0C
0 to +40C 50max
TEMPERATURE REGULATION[mV]
-10 to +40
C
60max
3
20max
*
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 to 3.63 4.50 to 5.50 Fixed (“Y”option is available for adjusting output voltage)
3.30 to 3.40 5.00 to 5.15 11.50 to 12.50 14.40 to 15.60
OUTPUT VOLTAGE SETTING[V]
23.00 to 25.00
23.00 to 25.00
34.50 to 37.50
46.00 to 50.00
55.20 to 67.20
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically
OVERVOLTAGE PROTECTION 4.00 to 5.25 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00
27.60 to 33.60
27.60 to 33.60
41.40 to 50.40
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
Not provided
Option (Refer to Instruction Manual)
.
*6
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)
INPUT-OUTPUT RC
INPUT-FG
ISOLATION
.
*6
*6
*4
OUTPUT RC-FG
OUTPUT-RC
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*8
Complies with IEC61000-3-2 (Class A)
75X37.0X160mm [2.95X1.46X6.30 inches] (WXHXD) / 390g max (with chassis & cover : 650g max)
OTHERS
*4
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1 Specification is changeed at option, refer to Instruction Manual.
at the rated input/output.
*8 Please contact us about another class.
*2 This is the value that measured on measuring board with *4 Derating is required.
*
To meet the specifications. Do not operate over-loaded
condition.
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
*5 ( ) means peak current. There is a possibility that an internal
device is damaged when the specification is exceeded. Please *
Parallel operation is not possible.
contact us about the detail.
*
*
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of
pulse load.
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when remote control (optional) is added.
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.
LFA-14
LFA150F
Block diagram
FUSE
250V5A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
LFA
FG
Photocoupler
OPTION
CURRENT
SENSING
RC
E
EXTERNAL
SOURCE
Photocoupler
Photocoupler
BOOSTER
INDUCTOR
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
INVERTER
CONTROL
INVERTER
CONTROL
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
TRANSFORMER
DC OUT
External view
¶
External size of option is different from standard model.
Standard type
Chassis and cover type
6
2-f4.5
176 0.5
[6.93]
4-M4
Mounting Hole
FG
Name plate
3-f3.5
Mounting Hole
Point A
Point B
[0.24]
1
1
FG
5
3
FG
Input(N)
Input(L)
5
3
CN3
CN3
Input(N)
Output(-)
Output(-)
1
1
Input(L)
7
1
7
1
CN1
CN1
CN2
CN2
Output(+)
Output(+)
6
6
2
1
2 1
CN4
Connector for Remote
4
ON/OFF (optional)
Voltage adjust
[0.16]
18
[0.71]
(LFA150F-3R3-Y,LFA150F-5-Y or Optional)
Mounting Hole
188
[7.4]
5
150 0.5
[5.91]
160
[0.2]
6
f4.5
176 0.5
[0.24]
[6.93]
[6.3]
2-M4
Mounting Hole
PCB t=1.6
¶1
¶1 Surface mount device
¶ 4 Mounting holes are existing.
¶
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
¶
¶
Connector type
CN4 Option (Mfr:J.S.T)
<PIN CONNECTION>
CN1
CN2
CN3
I/O Connector
Mating connector
Terminal
1123721-1
1318912-1
1123721-1
1318912-1
1123721-1
1318912-1
Pin No.
Input
AC(L)
Pin No. Output
Pin No. Output
PIN No.
Contents
RC(+)
Chain
Loose
Chain
Loose
Chain
Loose
1
2
3
4
5
1
2
CN1 1-1123724-3 1-1123722-5
CN2 1-1123723-6 1-1123722-6
CN3 1-1123723-7 1-1123722-7
RC(-)
AC(N)
1 to 7
-V
1 to 6
+V
Barrier strip type
Model B2B-XH-A
FG
¶ Keep drawing current per pin below 5A for CN2,CN3.
Mating Connector (Terminal)
XHP-2
(Mfr:Tyco Electronics)
¶ Tolerance : 1 [ 0.04]
¶ Weight : 390g max (with chassis & cover : 650g max)
¶ PCB material : CEM3
¶ I/O Connector is Mfr. Tyco Electronics
¶ Option:-J1:VH(J.S.T) connector type.
BXH-001T-P0.6
or SXH-001T-P0.6
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
¶
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max
LFA-15
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
240
F
-O -O
5 6
LFA240F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Recommended EMI/EMC Filter
NAC-06-472
R
LFA
*1
6Optional
C: with Coating
G: Low leakage current
H: with the function to be acceptable
to output peak current (only 24V)
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
J1: VH(J.S.T.)connector type
R: with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
SN: with Chassis & cover
T : Vertical terminal block
Y: with Potentiometer
Please refer to Instruction
manual 5.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
MODEL
LFA240F-24
240
LFA240F-24-H
240 (300)
LFA240F-36
241.2
LFA240F-48
240
*5
*5
MAX OUTPUT WATTAGE[W]
DC OUTPUT
24V 10A
24V 10 (12.5)A
36V 6.7A
48V 5A
SPECIFICATIONS
MODEL
LFA240F-24
LFA240F-24-H
LFA240F-36
LFA240F-48
*4
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 3.3typ (Io=100%)
ACIN 200V 1.7typ (Io=100%)
50 / 60 (47 - 63)
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V 84.5typ
84.5typ
87.5typ
84.5typ
87.5typ
84.5typ
87.5typ
EFFICIENCY[%]
INPUT
ACIN 200V 87.5typ
ACIN 100V 0.99typ
POWER FACTOR (Io=100%)
INRUSH CURRENT[A]
ACIN 200V 0.95typ
ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.40 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
24
24
36
48
*5
*7
*7
*2
10
10 (Peak12.5)
96max
6.7
5
CURRENT[A]
96max
150max
120max
160max
150max
180max
144max
240max
150max
200max
250max
300max
360max
450max
144max
192max
240max
150max
200max
250max
300max
480max
600max
192max
LINE REGULATION[mV]
LOAD REGULATION[mV]
150max
240max
320max
300max
360max
240max
290max
96max
0 to +40C
RIPPLE[mVp-p]
*2
*2
-10 - 0C
0 to +40C
RIPPLE NOISE[mVp-p]
*2
OUTPUT
-10 - 0C
0 to +40C 240max
TEMPERATURE REGULATION[mV]
-10 to +40
C
290max
3
96max
*
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
Fixed (“Y”option is available for adjusting output voltage)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
23.00 to 25.00
23.00 to 25.00
34.50 to 37.50
46.00 to 50.00
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically
OVERVOLTAGE PROTECTION 27.60 to 33.60 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
Option (Refer to Instruction Manual)
.
*6
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
INPUT-OUTPUT RC
INPUT-FG
ISOLATION
.
*6
*6
*4
OUTPUT RC-FG
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*8
Complies with IEC61000-3-2 (Class A)
84X46.5X180mm [3.31X1.83X7.09 inches] (WXHXD) / 550g max (with chassis & cover : 880g max)
OTHERS
*4
Convection (Refer to Instruction Manual 3.1 and 3.2)
*1 Specification is changeed at option, refer to Instruction Manual.
at the rated input/output.
*8 Please contact us about another class.
*2 This is the value that measured on measuring board with *4 Derating is required.
*
To meet the specifications. Do not operate over-loaded
condition.
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
*5 ( ) means peak current. There is a possibility that an internal
device is damaged when the specification is exceeded. Please *
Parallel operation is not possible.
contact us about the detail.
*
*
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of
pulse load.
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when remote control (optional) is added.
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.
LFA-16
LFA240F
Block diagram
FUSE
250V10A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
LFA
FG
Photocoupler
OPTION
CURRENT
SENSING
RC
E
EXTERNAL
SOURCE
Photocoupler
Photocoupler
BOOSTER
INDUCTOR
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
INVERTER
CONTROL
INVERTER
CONTROL
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
TRANSFORMER
DC OUT
External view
¶
External size of option is different from standard model.
Standard type
Chassis and cover type
Connector for Remote
ON/OFF (Optional)
200 0.5
[7.87]
6
[0.24]
2-f4.5
4-M4
Mounting Hole
16.5
[0.65]
4-f3.5
Mounting Hole
FG
Voltage adjust(Optional)
Name plate
1
2
1
2
CN4
1
1
FG
FG
5
3
5
3
CN3
Output(-)
CN3
Input(N)
Input(L)
Input(N)
Input(L)
Output(-)
1
1
CN1
CN1
7
1
7
1
CN2
CN2
Output(+)
Output(+)
6
6
4
[0.16]
89 0.5
[3.5]
Point A Point B
Mounting Hole
212
170 0.5
[6.69]
5
[0.2]
[8.35]
6
f4.5
200 0.5
[7.87]
180
[7.09]
[0.24]
2-M4
Mounting Hole
¶1
PCB t=1.6
¶1 Surface mount device
¶ 5 Mounting holes are existing.
¶
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
¶
¶
Connector type
<PIN CONNECTION>
CN1
CN2
CN3
CN4 Option (Mfr:J.S.T)
I/O Connector
Mating connector
Terminal
1123721-1
1318912-1
1123721-1
1318912-1
1123721-1
1318912-1
Pin No.
Input
AC(L)
Pin No. Output
Pin No. Output
PIN No.
Contents
RC(+)
Chain
Loose
Chain
Loose
Chain
Loose
1
2
3
4
5
1
2
CN1 1-1123724-3 1-1123722-5
CN2 1-1123723-6 1-1123722-6
CN3 1-1123723-7 1-1123722-7
RC(-)
AC(N)
1 to 7
-V
1 to 6
+V
Barrier strip type
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
FG
¶ Keep drawing current per pin below 5A for CN2,CN3.
(Mfr:Tyco Electronics)
¶ Tolerance : 1 [ 0.04]
¶ Weight : 550g max (with chassis & cover : 880g max)
¶ PCB material : CEM3
¶ I/O Connector is Mfr. Tyco Electronics
¶ Option:-J1:VH(J.S.T) connector type.
BXH-001T-P0.6
or SXH-001T-P0.6
¶ Optional chassis and cover material : Electric galvanizing steel board.
¶ Dimensions in mm, [ ]=inches
¶
Mounting torque (Mounting hole of chassis) :1.5N-m (16kgf-cm) max
LFA-17
Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LF
A
300
F
-O -O
5 6
LFA300F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Recommended EMI/EMC Filter
NAC-06-472
R
*1
6Optional
LFA
C: with Coating
G: Low leakage current
H: with the function to be acceptable
to output peak current
(Only 24V, 30V, 36V and 48V)
J : EP (Tyco Electronics) connector type
(Except 3.3V and 5V)
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
J1
:
VH (J.S.T.) connector type
(Except 3.3V and 5V)
R: with Remote ON/OFF
R2: with Remote ON/OFF
S : with Chassis
SNF
:
with Chassis & cover & fan
(Only 5V, 12V and 24V)
Holizontal terminal block
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit,
so handle the unit with care.
T1
:
Please refer to Instruction manual 5.
MODEL
LFA300F-3R3-TY LFA300F-5-TY LFA300F-12-TY LFA300F-15-TY LFA300F-24-TY LFA300F-24-HTY LFA300F-30-TY LFA300F-36-TY LFA300F-48-TY
*5
198
300
324
330
336
336 (456) 330
338.4
336
MAX OUTPUT WATTAGE[W]
Convection
Forced air
3.3V 40A
3.3V 60A
5V 40A
5V 60A
12V 17A
12V 27A
15V 14A
15V 22A
24V 12.5A 24V 12.5 (19)A 30V 10A
36V 8.4A
36V 9.4A
48V 6.3A
48V 7A
*5
DC OUTPUT
24V 14A
24V 14 (19)A 30V 11A
SPECIFICATIONS
MODEL
LFA300F-3R3-TY LFA300F-5-TY
LFA300F-12-TY
LFA300F-15-TY
LFA300F-24-TY
LFA300F-24-HTY LFA300F-30-TY
LFA300F-36-TY
LFA300F-48-TY
*4
VOLTAGE[V]
AC85 - 264 1f(Refer to Instruction Manual 1.1 and 3.2)
ACIN 100V 2.7typ (Io=100%) 4.1typ (Io=100%)
ACIN 200V 1.4typ (Io=100%) 2.0typ (Io=100%)
50 / 60 (47 - 63)
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V 75.0typ
ACIN 200V 77.0typ
ACIN 100V 0.98typ
ACIN 200V 0.92typ
79.0typ
82.5typ
0.99typ
0.95typ
80.0typ
83.0typ
81.5typ
84.5typ
85.0typ
88.0typ
85.0typ
88.0typ
85.5typ
88.0typ
85.5typ
88.0typ
85.5typ
88.0typ
EFFICIENCY[%]
INPUT
POWER FACTOR (Io=100%)
INRUSH CURRENT[A]
ACIN 100V 15 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
ACIN 200V 30 / 30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.45 / 0.75max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
24
30
36
48
Convection 40
Forced air 60
*7
40
60
17
27
14
22
12.5
14
12.5 (Peak19) 10
14 (Peak19) 11
8.4
9.4
6.3
7
*5
CURRENT[A]
20max
40max
80max
140max
120max
160max
20max
40max
80max
140max
120max
160max
50max
60max
20max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
96max
144max
144max
240max
150max
200max
250max
300max
360max
450max
144max
192max
240max
150max
200max
250max
300max
480max
600max
192max
LINE REGULATION[mV]
LOAD REGULATION[mV]
*7
*2
*2
*2
150max
240max
320max
300max
360max
240max
290max
96max
240max
150max
200max
250max
300max
360max
450max
144max
0 to +40C
RIPPLE[mVp-p]
-10 - 0C
0 to +40C
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
*2
-10 - 0C
0 to +40C 50max
-10 to +40
C
60max
3
20max
*
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
350typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
2.85 to 3.63 4.50 to 5.50
3.30 to 3.40 5.00 to 5.15
10.80 to 13.20 13.50 to 16.50 21.60 to 27.50 21.60 to 27.50 27.00 to 33.00 32.40 to 39.60 39.60 to 52.80
12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 24.00 to 24.96 30.00 to 31.20 36.00 to 37.44 48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION Works over 105% of rating (works over 101% of peak current at option -H) and recovers automatically
OVERVOLTAGE PROTECTION
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 27.60 to 33.60 34.50 to 42.00 41.40 to 50.40 55.20 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
Not provided
Not provided
Option (Refer to Instruction Manual)
OTHERS
REMOTE SENSING
REMOTE ON/OFF
.
*6
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At Room Temperature)
AC100V 1minute, Cutoff current = 25mA, DC100V 10MWmin (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
INPUT-OUTPUT RC
INPUT-FG
ISOLATION
.
*6
*6
*4
OUTPUT RC-FG
OUTPUT-RC
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axis
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
SAFETY AND
NOISE
REGULATIONS
*8
Complies with IEC61000-3-2 (Class A)
95X52.5X222mm [3.74X2.07X8.74 inches] (WXHXD) (without terminal block) / 810g max (with chassis & cover : 1,270g max)
OTHERS
*4
Convection / Forced air (Refer to Instruction Manual 3.1 and 3.2)
*1 Specification is changeed at option, refer to Instruction Manual.
at the rated input/output.
*8 Please contact us about another class.
*2 This is the value that measured on measuring board with *4 Derating is required.
*
To meet the specifications. Do not operate over-loaded
condition.
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
*5 ( ) means peak current. There is a possibility that an internal
device is damaged when the specification is exceeded. Please *
Parallel operation is not possible.
contact us about the detail.
*
*
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of
pulse load.
*3 Drift is the change in DC output for an eight hour period after a *6 Applicable when remote control (optional) is added.
half-hour warm-up at 25C, with the input voltage held constant *7 Please contact us about dynamic load and input response.
LFA-18
LFA300F
Block diagram
FUSE
250V10A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
LFA
FG
Photocoupler
OPTION
CURRENT
SENSING
RC
EXTERNAL
SOURCE
E
Photocoupler
Photocoupler
BOOSTER
INDUCTOR
CURRENT
SENSING
RECTIFIER
AND
FILTER
CONTROL
INVERTER
CONTROL
INVERTER
CONTROL
OVER VOLTAGE
PROTECTION
RECTIFIER
AND
FILTER
TRANSFORMER
DC OUT
External view
¶
External size of option is different from standard model.
Standard type
Connector for
Point B
4-f3.5
Mounting Hole
Name plate
FG
Point C
Point D
Remote ON/OFF
(Optional)
M4
1
2
CN4
FG
TB2
Input(N)
Output(-)
Input(L)
TB1
Output(+)
M4
4
[0.16]
5
[0.2]
109 0.5
[4.29]
Voltage adjust
Mounting Hole
Point A
46.5
[1.83]
212 0.5
[8.35]
Connector type
CN4 Option (Mfr:J.S.T)
222
[8.74]
PIN No.
Contents
RC(+)
1
2
RC(-)
Barrier strip type
Model B2B-XH-A
Mating Connector (Terminal)
XHP-2
PCB t=1.6
¶1
¶1 Surface mount device
BXH-001T-P0.6
or SXH-001T-P0.6
¶ 5 Mounting holes are existing.
¶ Tolerance : 1 [ 0.04]
¶ Weight : 810g max (with chassis & cover : 1,270g max)
¶ PCB material : CEM3
¶
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B, Point C, Point D are thermometry points.
Please refer to Instruction Manual 3.
¶ Dimensions in mm, [ ]=inches
¶
¶
¶
Screw tightening torque : M4 1.6N-m (16.9kgf-cm) max
¶ Keep drawing current per pin below 20A for TB2.
LFA-19
相关型号:
©2020 ICPDF网 联系我们和版权申明