PLA15F-12 [COSEL]

AC/DC CONVERTER 12V 15W;
PLA15F-12
型号: PLA15F-12
厂家: COSEL CO., LTD.    COSEL CO., LTD.
描述:

AC/DC CONVERTER 12V 15W

文件: 总14页 (文件大小:1159K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ordering information  
AC-DC Power Supplies Enclosed Type  
PL  
A
15  
F
-O -O  
5 6  
PLA15F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-04-472  
R
*7  
6Optional  
C: with Coating  
J : Connector interface  
T : Vertical terminal block  
-NO: with DIN rail  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
See 5.1 in Instruction Manual.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
SPECIFICATIONS  
MODEL  
PLA15F-5  
PLA15F-12  
PLA15F-15  
PLA15F-24  
*3  
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)  
ACIN 100V 0.4typ (Io=90%)  
VOLTAGE[V]  
ACIN 115V 0.4typ (Io=100%)  
ACIN 230V 0.25typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
EFFICIENCY[%]  
ACIN 100V 72.5typ (Io=90%)  
ACIN 115V 73.5typ (Io=100%)  
ACIN 230V 75.5typ (Io=100%)  
75.5typ (Io=90%)  
77.0typ (Io=100%)  
78.5typ (Io=100%)  
77.0typ (Io=90%)  
78.5typ (Io=100%)  
79.5typ (Io=100%)  
78.0typ (Io=90%)  
79.0typ (Io=100%)  
80.0typ (Io=100%)  
INPUT  
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start  
ACIN 115V 16typ (Io=100%) Ta=25Cat cold start  
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.30max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
5
3
12  
15  
1
24  
1.3  
0.7  
CURRENT[A]  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
WATTAGE[W]  
ACIN 115V-264V 15.0  
15.6  
15.0  
16.8  
*
4
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
48max  
60max  
96max  
*
4
100max  
120max  
160max  
240max  
150max  
180max  
300max  
120max  
150max  
48max  
120max  
120max  
160max  
240max  
150max  
180max  
300max  
150max  
180max  
60max  
150max  
120max  
160max  
280max  
150max  
180max  
320max  
240max  
290max  
96max  
0 to +50C 80max  
-10 to 0C 140max  
Io=0 to 35% 160max  
0 to +50C 120max  
-10 to 0C 160max  
Io=0 to 35% 240max  
0 to +50C 50max  
-10 to +50C 60max  
RIPPLE[mVp-p]  
*1  
OUTPUT  
RIPPLE NOISE[mVp-p] *1  
TEMPERATURE REGULATION[mV]  
*
2
20max  
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
200typ (ACIN 115V, Io=100%) *Start-up time is 700 ms typ for less than 1 minute of applying input again from turning off the input voltage.  
20typ (ACIN 115V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50  
10.80 to 13.20  
12.00 to 12.48  
13.50 to 16.50  
15.00 to 15.60  
21.60 to 26.40  
24.00 to 24.96  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
5.00 to 5.15  
Works over 105% of rating and recovers automatically  
13.80 to 16.80  
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00  
17.25 to 21.00  
27.60 to 33.60  
PROTECTION  
CIRCUIT AND  
OTHERS  
OPERATING INDICATION  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
LED (Green)  
Not provided  
Not provided  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)  
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max  
INPUT-FG  
ISOLATION  
OUTPUT-FG  
*
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axes  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
Complies with IEC61000-3-2 class A  
SAFETY AND  
NOISE  
REGULATIONS  
*
8
April17, 2018  
PLA-2  
PLA15F  
SPECIFICATIONS  
CASE SIZE/WEIGHT  
38X80X73mm [1.50X3.15X2.87 inches] (Excluding terminal block and screw) (WXHXD) / 250g max  
OTHERS  
COOLING METHOD  
Convection  
*
6
WARRANTY WARRANTY  
5 years (subject to the operating conditions)  
*1 This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150  
mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-  
Giken RM103.  
*5 Output power derating is required. See 3.2 in Instruction Manual.  
*6 See 3.3 in Instruction Manual for more details.  
*7 Consult us about safety agency approvals for the models with optional functions.  
*8 Consult us about other classes.  
See 1.6 of Instruction Manual for more details.  
When the load factor is 0 - 35%, the switching power loss is reduced by burst operation, which will  
cause ripple and ripple noise to go beyond the specifications.  
*
Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.  
Otherwise the internal components may be damaged.  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.  
*3 As for DC input, consult us for advice.  
*
*
Parallel operation is not possible with this mode.  
Sound noise may be heard from the power supply when used for pulse load.  
*4 Consult us about dynamic load and input response. Measure the output voltage by using the average mode  
of the tester to deal with the burst operation at 35% load or less.  
Features  
-
-
-
-
Compact design (Depth: 73mm 2.87inches)  
Low power consumption (1.0W typ AC240Vin, no load at standard model)  
UL508 approved (Except option -J), and complies with SEMI F47  
Various connection interface options (vertical terminal [-T], AMP connector [-J])  
Block diagram  
FUSE  
AC250V 2.5A  
INRUSH  
CURRENT  
LIMIT  
RECTIFIER  
AND  
FILTER  
NOISE  
FILTER  
AC IN 85 - 264V  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
OVER CURRENT  
SENSING  
Photocoupler  
Photocoupler  
CONTROL  
OVER VOLTAGE  
PROTECTION  
External view  
2-M3  
Point A  
Name plate  
TB1  
Mounting hole  
(Bottom side)  
M3.5  
AC(L)  
AC(N)  
FG(  
Output terminal(-)  
Output terminal(+)  
)
Output voltage  
adjustable potentiometer  
Terminal cover  
LED  
±0.5  
18  
35.5  
[1.4]  
[0.71]  
±1.5  
15.3  
[0.6]  
(LED)  
12.5max  
[0.49]  
73  
[2.87]  
14 ±1.5  
[0.55]  
±1.5  
11.6  
(Potentiometer)  
[0.46]  
Tolerance : 1 [ 0.04]  
Weight  
PCB Material/thickness  
Chassis material  
Case material : Electric galvanizing steel board  
Dimensions in mm, [ ]=inches  
: 250g max  
:
CEM-3 / 1.6mm [0.06inches]  
:
Electric galvanizing steel board  
2-M3  
±0.5  
46  
[1.81]  
18  
[0.71]  
Mounting torque  
Screw tightening torque : 1.0N-m max  
: 0.6N m max  
-
Mounting hole  
April17, 2018  
PLA-3  
Ordering information  
AC-DC Power Supplies Enclosed Type  
PL  
A
30  
F
-O -O  
5 6  
PLA30F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-04-472  
R
*7  
6Optional  
C: with Coating  
J : Connector interface  
T : Vertical terminal block  
-NO: with DIN rail  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
See 5.1 in Instruction Manual.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
SPECIFICATIONS  
MODEL  
PLA30F-5  
PLA30F-12  
PLA30F-15  
PLA30F-24  
*3  
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)  
ACIN 100V 0.7typ (Io=90%)  
VOLTAGE[V]  
ACIN 115V 0.7typ (Io=100%)  
ACIN 230V 0.4typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
EFFICIENCY[%]  
ACIN 100V 73.0typ (Io=90%)  
ACIN 115V 74.0typ (Io=100%)  
ACIN 230V 77.0typ (Io=100%)  
80.0typ (Io=90%)  
80.5typ (Io=100%)  
81.0typ (Io=100%)  
81.0typ (Io=90%)  
81.5typ (Io=100%)  
82.0typ (Io=100%)  
82.5typ (Io=90%)  
83.0typ (Io=100%)  
83.5typ (Io=100%)  
INPUT  
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start  
ACIN 115V 16typ (Io=100%) Ta=25Cat cold start  
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start  
INRUSH CURRENT[A]  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.65max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
5
6
12  
15  
2
24  
2.5  
1.3  
CURRENT[A]  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
WATTAGE[W]  
ACIN 115V-264V 30.0  
30.0  
30.0  
31.2  
*
4
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
*
4
0 to +50C 80max  
-10 to 0C 140max  
0 to +50C 120max  
-10 to 0C 160max  
0 to +50C 50max  
-10 to +50C 60max  
RIPPLE[mVp-p]  
*1  
OUTPUT  
RIPPLE NOISE[mVp-p] *1  
TEMPERATURE REGULATION[mV]  
*
2
20max  
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
150typ (ACIN 115V, Io=100%)  
20typ (ACIN 115V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50  
10.80 to 13.20  
12.00 to 12.48  
13.50 to 16.50  
15.00 to 15.60  
21.60 to 26.40  
24.00 to 24.96  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
5.00 to 5.15  
Works over 105% of rating and recovers automatically  
13.80 to 16.80  
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00  
17.25 to 21.00  
27.60 to 33.60  
PROTECTION  
CIRCUIT AND  
OTHERS  
OPERATING INDICATION  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
LED (Green)  
Not provided  
Not provided  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)  
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max  
INPUT-FG  
ISOLATION  
OUTPUT-FG  
*
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axes  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
Complies with IEC61000-3-2 class A  
SAFETY AND  
NOISE  
REGULATIONS  
*
8
April17, 2018  
PLA-4  
PLA30F  
SPECIFICATIONS  
CASE SIZE/WEIGHT  
38X80X88mm [1.50X3.15X3.46 inches] (Excluding terminal block and screw) (WXHXD) / 330g max  
OTHERS  
COOLING METHOD  
Convection  
*
6
WARRANTY WARRANTY  
5 years (subject to the operating conditions)  
*1 This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150  
mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-  
Giken RM103.  
*7 Consult us about safety agency approvals for the models with optional functions.  
*8 Consult us about other classes.  
*
Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.  
Otherwise the internal components may be damaged.  
See 1.6 of Instruction Manual for more details.  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.  
*3 As for DC input, consult us for advice.  
*
*
Parallel operation is not possible with this mode.  
Sound noise may be heard from the power supply when used for pulse load.  
*4 Consult us about dynamic load and input response.  
*5 Output power derating is required. See 3.2 in Instruction Manual.  
*6 See 3.3 in Instruction Manual for more details.  
Features  
-
-
-
Compact design (Depth: 88mm 3.46inches)  
UL508 approved (Except option -J), and complies with SEMI F47  
Various connection interface options (vertical terminal [-T], AMP connector [-J])  
Block diagram  
FUSE  
AC250V 3.15A  
INRUSH  
CURRENT  
LIMIT  
RECTIFIER  
AND  
FILTER  
NOISE  
FILTER  
AC IN 85 - 264V  
FG  
TRANSFORMER  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
FILTER  
OVER CURRENT  
SENSING  
Photocoupler  
Photocoupler  
CONTROL  
OVER VOLTAGE  
PROTECTION  
External view  
2-M3  
Point A  
Name plate  
Mounting hole  
TB1  
(Bottom side)  
M3.5  
AC(L)  
AC(N)  
FG(  
Output terminal(  
Output terminal(+)  
)
-)  
Output voltage  
adjustable potentiometer  
Terminal cover  
LED  
±0.5  
19  
62.5  
[2.46]  
[0.75]  
15.3 ±1.5  
[0.6]  
12.5max  
[0.49]  
88  
[3.46]  
(LED)  
14 ±1.5  
[0.55]  
(Potentiometer)  
11.6±1.5  
[0.46]  
Tolerance : 1 [ 0.04]  
Weight  
PCB Material/thickness  
Chassis material Electric galvanizing steel board  
Case material : Electric galvanizing steel board  
Dimensions in mm, [ ]=inches  
: 330g max  
:
CEM-3 / 1.6mm [0.06inches]  
:
38  
[1.5]  
41 ±0.5  
[1.61]  
Mounting torque  
Screw tightening torque : 1.0N-m max  
: 0.6N m max  
-
2-M3  
Mounting hole  
April17, 2018  
PLA-5  
Ordering information  
AC-DC Power Supplies Enclosed Type  
PL  
A
50  
F
-O -O  
5 6  
PLA50F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-04-472  
R
*7  
6Optional  
C: with Coating  
J : Connector interface  
T : Vertical terminal block  
-NO: with DIN rail  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
See 5.1 in Instruction Manual.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
SPECIFICATIONS  
MODEL  
PLA50F-5  
PLA50F-12  
PLA50F-15  
PLA50F-24  
*3  
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)  
VOLTAGE[V]  
ACIN 100V 0.6typ (Io=90%)  
0.7typ (Io=90%)  
0.7typ (Io=100%)  
0.4typ (Io=100%)  
CURRENT[A]  
ACIN 115V 0.6typ (Io=100%)  
ACIN 230V 0.3typ (Io=100%)  
50 / 60 (47 - 63)  
FREQUENCY[Hz]  
EFFICIENCY[%]  
ACIN 100V 74.5typ (Io=90%)  
ACIN 115V 75.0typ (Io=100%)  
ACIN 230V 76.5typ (Io=100%)  
ACIN 100V 0.97typ (Io=90%)  
ACIN 115V 0.97typ (Io=100%)  
ACIN 230V 0.85typ (Io=100%)  
80.0typ (Io=90%)  
80.5typ (Io=100%)  
82.0typ (Io=100%)  
0.98typ (Io=90%)  
0.98typ (Io=100%)  
0.87typ (Io=100%)  
80.0typ (Io=90%)  
80.5typ (Io=100%)  
82.0typ (Io=100%)  
81.5typ (Io=90%)  
82.0typ (Io=100%)  
84.0typ (Io=100%)  
INPUT  
POWER FACTOR  
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start  
INRUSH CURRENT[A] ACIN 115V 16typ (Io=100%) Ta=25Cat cold start  
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
CURRENT[A]  
0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
5
8
12  
15  
24  
4.3  
3.5  
2.2  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
WATTAGE[W]  
ACIN 115V-264V 40.0  
51.6  
52.5  
52.8  
*
4
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
150max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
*
4
0 to +45C 80max  
-10 to 0C 140max  
0 to +45C 120max  
-10 to 0C 160max  
0 to +45C 50max  
-10 to +45C 60max  
RIPPLE[mVp-p]  
*1  
OUTPUT  
RIPPLE NOISE[mVp-p] *1  
TEMPERATURE REGULATION[mV]  
*
2
20max  
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
350typ (ACIN 115V, Io=100%)  
20typ (ACIN 115V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50  
10.80 to 13.20  
12.00 to 12.48  
13.50 to 16.50  
15.00 to 15.60  
21.60 to 26.40  
24.00 to 24.96  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
5.00 to 5.15  
Works over 105% of rating and recovers automatically  
13.80 to 16.80  
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00  
17.25 to 21.00  
27.60 to 33.60  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
LED (Green)  
Not provided  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
INPUT-FG  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)  
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max  
ISOLATION  
OUTPUT-FG  
*
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axes  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
Complies with IEC61000-3-2 class A  
SAFETY AND  
NOISE  
REGULATIONS  
*
8
April17, 2018  
PLA-6  
PLA50F  
SPECIFICATIONS  
CASE SIZE/WEIGHT  
38X80X99mm [1.50X3.15X3.90 inches] (Excluding terminal block and screw) (WXHXD) / 400g max  
OTHERS  
COOLING METHOD  
Convection  
*
6
WARRANTY WARRANTY  
5 years (subject to the operating conditions)  
*1 This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150  
mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-  
Giken RM103.  
*7 Consult us about safety agency approvals for the models with optional functions.  
*8 Consult us about other classes.  
*
Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.  
Otherwise the internal components may be damaged.  
See 1.6 of Instruction Manual for more details.  
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.  
*3 As for DC input, consult us for advice.  
*
*
Parallel operation is not possible with this mode.  
Sound noise may be heard from the power supply when used for pulse load.  
*4 Consult us about dynamic load and input response.  
*5 Output power derating is required. See 3.2 in Instruction Manual.  
*6 See 3.3 in Instruction Manual for more details.  
Features  
-
-
-
Compact design (Depth: 99mm 3.90inches)  
UL508 approved (Except option -J), and complies with SEMI F47  
Various connection interface options (vertical terminal [-T], AMP connector [-J])  
Block diagram  
FUSE  
AC250V 2.5A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
AC IN 85 - 264V  
FG  
RECTIFIER  
TRANSFORMER  
BOOSTER  
INDUCTOR  
CURRENT  
SENSING  
RECTIFIER  
AND  
CONTROL  
INVERTER  
DC OUT  
RECTIFIER  
AND  
FILTER  
FILTER  
Photocoupler  
Photocoupler  
OVER CURRENT  
SENSING  
INVERTER  
CONTROL  
CONTROL  
OVER VOLTAGE  
PROTECTION  
External view  
2-M3  
Point A  
Mounting hole  
Name plate  
TB1  
(Bottom side)  
M3.5  
AC(L)  
AC(N)  
FG(  
Output terminal(  
Output terminal(+)  
)
-
)
Output voltage  
adjustable potentiometer  
Terminal cover  
LED  
19  
[0.75]  
76 ±0.5  
[2.99]  
15.3 ±1.5  
[0.6]  
12.5max  
[0.49]  
99  
[3.9]  
(LED)  
14 ±1.5  
[0.55]  
(Potentiometer)  
11.6±1.5  
[0.46]  
Tolerance : 1 [ 0.04]  
Weight  
PCB Material/thickness  
Chassis material Electric galvanizing steel board  
Case material : Electric galvanizing steel board  
Dimensions in mm, [ ]=inches  
: 400g max  
:
CEM-3 / 1.6mm [0.06inches]  
:
±0.5  
52  
[2.05]  
38  
[1.5]  
2-M3  
Mounting torque  
Screw tightening torque : 1.0N-m max  
: 0.6N m max  
-
Mounting hole  
April17, 2018  
PLA-7  
Ordering information  
AC-DC Power Supplies Enclosed Type  
PL  
A
100  
F
-O -O  
5 6  
PLA100F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-04-472  
R
*7  
6Optional  
C: with Coating  
R: Remote on/off  
(Required external  
power source)  
J : Connector interface  
T : Vertical terminal block  
-NO: with DIN rail  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
See 5.1 in Instruction Manual.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
SPECIFICATIONS  
*Please consider "PBA100F-5-N" about 5V output with case cover.  
MODEL  
PLA100F-12  
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)  
ACIN 100V 1.2typ (Io=90%)  
PLA100F-15  
PLA100F-24  
PLA100F-36  
PLA100F-48  
*3  
VOLTAGE[V]  
CURRENT[A]  
ACIN 115V 1.1typ (Io=100%)  
ACIN 230V 0.6typ (Io=100%)  
50 / 60 (47 - 63)  
FREQUENCY[Hz]  
EFFICIENCY[%]  
ACIN 100V 82typ (Io=90%)  
ACIN 115V 82typ (Io=100%)  
ACIN 230V 85typ (Io=100%)  
ACIN 100V 0.98typ (Io=90%)  
ACIN 115V 0.98typ (Io=100%)  
83typ (Io=90%)  
83typ (Io=100%)  
86typ (Io=100%)  
85typ (Io=90%)  
85typ (Io=100%)  
88typ (Io=100%)  
86typ (Io=90%)  
86typ (Io=100%)  
89typ (Io=100%)  
86typ (Io=90%)  
86typ (Io=100%)  
89typ (Io=100%)  
INPUT  
POWER FACTOR  
ACIN 230V 0.95typ (Io=100%) *Power factor correction is stopped at AC250V or more.  
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start  
INRUSH CURRENT[A] ACIN 115V 16typ (Io=100%) Ta=25Cat cold start  
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
12 15 24 36  
48  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
CURRENT[A]  
ACIN 115V-264V 8.4  
6.7  
4.3  
2.8  
2.1  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
WATTAGE[W]  
ACIN 115V-264V 100.8  
100.5  
103.2  
100.8  
100.8  
*
4
48max  
LINE REGULATION[mV]  
60max  
120max  
96max  
150max  
144max  
150max  
192max  
300max  
Io=30 to 100% 100max  
LOAD REGULATION  
*
4
[mV]  
Io=0 to 30% Burst operation (Please contact us about detail)  
0 to +40C 120max  
-10 to 0C 160max  
Io=0 to 30% 500max  
0 to +40C 150max  
-10 to 0C 180max  
Io=0 to 30% 600max  
0 to +40C 120max  
-10 to +40C 180max  
120max  
160max  
500max  
150max  
180max  
600max  
150max  
180max  
60max  
120max  
160max  
500max  
150max  
180max  
600max  
240max  
290max  
96max  
150max  
200max  
500max  
200max  
240max  
600max  
360max  
440max  
144max  
150max  
400max  
500max  
200max  
500max  
600max  
480max  
600max  
192max  
RIPPLE[mVp-p]  
*1  
Io: load factor  
OUTPUT  
RIPPLE NOISE[mVp-p]  
*1  
Io: load factor  
TEMPERATURE REGULATION[mV]  
*
2
48max  
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
500typ (ACIN 115V, Io=100%) Ta=25C  
20typ (ACIN 115V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20  
13.50 to 16.50  
15.00 to 15.60  
21.60 to 26.40  
24.00 to 24.96  
32.40 to 39.60  
36.00 to 37.44  
43.20 to 52.80  
48.00 to 49.92  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
12.00 to 12.48  
Works over 105% of rating and recovers automatically  
17.25 to 21.00 27.60 to 33.60  
OVERVOLTAGE PROTECTION[V] 13.80 to 16.80  
41.40 to 50.40  
54.00 to 67.20  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
LED (Green)  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
INPUT-FG  
Optional (Required external power source. Option -R)  
*
9
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)  
ISOLATION  
*
*
9
9
OUTPUT RC-FG  
OUTPUT-RC  
*
5
-20 to +70C(Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axes  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
Complies with IEC61000-3-2 class A  
SAFETY AND  
NOISE  
REGULATIONS  
*
8
April17, 2018  
PLA-8  
PLA100F  
SPECIFICATIONS  
CASE SIZE/WEIGHT  
41X97X109mm [1.61X3.82X4.29 inches] (Excluding terminal block and screw) (WXHXD) / 500g max  
OTHERS  
COOLING METHOD  
Convection  
*
6
WARRANTY WARRANTY  
5 years (subject to the operating conditions)  
*1 This is the result of measurement of the testing board with  
capacitors of 22mF and 0.1mF placed at 150 mm from the  
output terminals by a 20 MHz oscilloscope or a ripple-noise meter  
equivalent to Keisoku-Giken RM103.  
hour warm-up at 25C.  
*9 The RC terminal is added to option –R models.The RC terminal is  
*3 As for DC input, consult us for advice.  
isolated from input, output, and FG.  
*4 Consult us about dynamic load and input response. Measure the output *  
voltage by using the average mode of the tester to deal with the burst  
operation at 30% load or less.  
Do not use the power supply in overcurrent conditions or in unspecified  
input voltage ranges. Otherwise the internal components may be  
damaged.  
See 1.6 of Instruction Manual for more details.  
When the load factor is 0 - 30%, the switching power loss is  
reduced by burst operation, which will cause ripple and ripple  
noise to go beyond the specifications.  
*5 Output power derating is required. See 3.2 in Instruction Manual.  
*6 See 3.3 in Instruction Manual for more details.  
*
*
Parallel operation is not possible with this mode.  
Sound noise may be heard from the power supply when used for  
pulse load.  
*7 Consult us about safety agency approvals for the models with optional functions.  
*8 Consult us about other classes.  
*2 Drift is the change in DC output for an eight hour period after a half-  
Features  
-
-
-
-
-
Compact design (Depth: 109mm 4.29inches)  
High efficiency (88%typ PLA100F-24, AC230Vin, 100% load)  
Low power consumption (1.5W typ AC240Vin, no load at standard model)  
UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1)  
Various connection interface options (vertical terminal [-T], AMP connector [-J])  
Block diagram  
FUSE  
250V 3.15A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
RC(-R)  
CURRENT  
SENSING  
BOOSTER  
INDUCTOR  
EXTERNAL  
SOURCE  
CONTROL  
RECTIFIER  
AND  
FILTER  
CURRENT  
SENSING  
OVER VOLTAGE  
PROTECTION  
INVERTER  
RECTIFIER  
AND  
INVERTER  
DC OUT  
FILTER  
CONTROL  
External view  
The external size of –R option, –J option, –N1 option and –T option models is different from the standard model. See “5. Options and  
Others” in Instruction Manual for more details.  
2-M3  
Name plate  
Mounting hole  
(Bottom side)  
M3.5  
AC(L)  
Terminal cover  
AC(N)  
Point A  
FG(  
)
Output terminal(–)  
Output terminal(+)  
Output voltage  
adjustable potentiometer  
LED  
2
1
CN4  
Connector for  
Remote ON/OFF (option)  
19.5  
[0.77]  
76±0.5  
[2.99]  
109  
14±1.5  
[0.55]  
12.5max  
[0.49]  
15.3±1.5 (LED)  
[0.6]  
[4.29]  
11.6±1.5 (potentiometer)  
[0.46]  
4
[0.16]  
101  
[3.98]  
Tolerance : 1 [ 0.04]  
Weight  
PCB Material/thickness  
Chassis material Aluminum  
Cover material : Electric galvanizing steel board  
Dimensions in mm, [ ]=inches  
Mounting torque : 0.49N m max  
-
Screw tightening torque : M3.5 1.0N-m max  
Connect the input FG to safety earth ground.  
: 500g max  
:
CEM-3 / 1.6mm [0.06inches]  
:
3-M3  
Mounting hole  
33.5  
[1.32]  
66.5±0.5  
[2.62]  
April17, 2018  
PLA-9  
Ordering information  
AC-DC Power Supplies Enclosed Type  
PL  
A
150  
F
-O -O  
5 6  
PLA150F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-04-472  
R
*7  
6Optional  
C: with Coating  
R: Remote on/off  
(Required external  
power source)  
J : Connector interface  
T : Vertical terminal block  
-NO: with DIN rail  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
See 5.1 in Instruction Manual.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
SPECIFICATIONS  
*Please consider "PBA150F-5-N" about 5V output with case cover.  
MODEL  
PLA150F-12  
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)  
ACIN 100V 1.7typ (Io=90%)  
PLA150F-15  
PLA150F-24  
PLA150F-36  
PLA150F-48  
*3  
VOLTAGE[V]  
CURRENT[A]  
ACIN 115V 1.6typ (Io=100%)  
ACIN 230V 0.8typ (Io=100%)  
50 / 60 (47 - 63)  
FREQUENCY[Hz]  
EFFICIENCY[%]  
ACIN 100V 84typ (Io=90%)  
ACIN 115V 84typ (Io=100%)  
ACIN 230V 87typ (Io=100%)  
ACIN 100V 0.98typ (Io=90%)  
ACIN 115V 0.98typ (Io=100%)  
84typ (Io=90%)  
84typ (Io=100%)  
87typ (Io=100%)  
87typ (Io=90%)  
87typ (Io=100%)  
90typ (Io=100%)  
87typ (Io=90%)  
87typ (Io=100%)  
90typ (Io=100%)  
87typ (Io=90%)  
87typ (Io=100%)  
90typ (Io=100%)  
INPUT  
POWER FACTOR  
ACIN 230V 0.95typ (Io=100%) *Power factor correction is stopped at AC250V or more.  
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start  
INRUSH CURRENT[A] ACIN 115V 16typ (Io=100%) Ta=25Cat cold start  
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
12 15 24 36  
48  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
10 6.4 4.2  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
CURRENT[A]  
ACIN 115V-264V 12.5  
3.2  
WATTAGE[W]  
ACIN 115V-264V 150.0  
150.0  
153.6  
151.2  
153.6  
*
4
48max  
LINE REGULATION[mV]  
60max  
120max  
96max  
150max  
144max  
150max  
192max  
300max  
Io=30 to 100% 100max  
LOAD REGULATION  
*
4
[mV]  
Io=0 to 30% Burst operation (Please contact us about detail)  
0 to +40C 120max  
-10 to 0C 160max  
Io=0 to 30% 500max  
0 to +40C 150max  
-10 to 0C 180max  
Io=0 to 30% 600max  
0 to +40C 120max  
-10 to +40C 180max  
120max  
160max  
500max  
150max  
180max  
600max  
150max  
180max  
60max  
120max  
160max  
500max  
150max  
180max  
600max  
240max  
290max  
96max  
150max  
200max  
500max  
200max  
240max  
600max  
360max  
440max  
144max  
150max  
400max  
500max  
200max  
500max  
600max  
480max  
600max  
192max  
RIPPLE[mVp-p]  
*1  
Io: load factor  
OUTPUT  
RIPPLE NOISE[mVp-p]  
*1  
Io: load factor  
TEMPERATURE REGULATION[mV]  
*
2
48max  
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
500typ (ACIN 115V, Io=100%) Ta=25C  
20typ (ACIN 115V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20  
13.50 to 16.50  
15.00 to 15.60  
21.60 to 26.40  
24.00 to 24.96  
32.40 to 39.60  
36.00 to 37.44  
43.20 to 52.80  
48.00 to 49.92  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
12.00 to 12.48  
Works over 105% of rating and recovers automatically  
17.25 to 21.00 27.60 to 33.60  
OVERVOLTAGE PROTECTION[V] 13.80 to 16.80  
41.40 to 50.40  
54.00 to 67.20  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
LED (Green)  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
INPUT-FG  
Optional (Required external power source. Option -R)  
*
9
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)  
ISOLATION  
*
*
9
9
OUTPUT RC-FG  
OUTPUT-RC  
*
5
-20 to +70C(Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max  
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axes  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
Complies with IEC61000-3-2 class A  
SAFETY AND  
NOISE  
REGULATIONS  
*
8
April17, 2018  
PLA-10  
PLA150F  
SPECIFICATIONS  
CASE SIZE/WEIGHT  
41X97X129mm [1.61X3.82X5.08 inches] (Excluding terminal block and screw) (WXHXD) / 600g max  
OTHERS  
COOLING METHOD  
Convection  
*
6
WARRANTY WARRANTY  
5 years (subject to the operating conditions)  
*1 This is the result of measurement of the testing board with capacitors of  
22mF and 0.1mF placed at 150 mm from the output terminals by a 20  
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken  
RM103.  
hour warm-up at 25C.  
*9 The RC terminal is added to option –R models. The RC terminal  
*3 As for DC input, consult us for advice.  
is isolated from input, output, and FG.  
*4 Consult us about dynamic load and input response. Measure the output  
voltage by using the average mode of the tester to deal with the burst  
operation at 30% load or less.  
*
Do not use the power supply in overcurrent conditions or in unspecified  
input voltage ranges. Otherwise the internal components may be  
damaged.  
See 1.6 of Instruction Manual for more details.  
When the load factor is 0 - 30%, the switching power loss is reduced by *5 Output power derating is required. See 3.2 in Instruction Manual.  
*
*
Parallel operation is not possible with this mode.  
Sound noise may be heard from the power supply when used for  
pulse load.  
burst operation, which will cause ripple and ripple noise to go beyond  
the specifications.  
*6 See 3.3 in Instruction Manual for more details.  
*7 Consult us about safety agency approvals for the models with optional functions.  
*8 Consult us about other classes.  
*2 Drift is the change in DC output for an eight hour period after a half-  
Features  
-
-
-
-
-
Compact design (Depth: 129mm 5.08inches)  
High efficiency (90%typ PLA150F-24, AC230Vin, 100% load)  
Low power consumption (1.5W typ AC240Vin, no load at standard model)  
UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1)  
Various connection interface options (vertical terminal [-T], AMP connector [-J])  
Block diagram  
FUSE  
250V 4A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
RC(-R)  
CURRENT  
SENSING  
BOOSTER  
INDUCTOR  
EXTERNAL  
SOURCE  
CONTROL  
RECTIFIER  
AND  
FILTER  
CURRENT  
SENSING  
OVER VOLTAGE  
PROTECTION  
INVERTER  
RECTIFIER  
AND  
INVERTER  
DC OUT  
FILTER  
CONTROL  
External view  
The external size of –R option, –J option, –N1 option and –T option models is different from the standard model. See “5. Options and  
Others” in Instruction Manual for more details.  
2-M3  
Name plate  
Mounting hole  
(Bottom side)  
Point B  
M3.5  
AC(L)  
AC(N)  
Terminal cover  
Point A  
FG(  
)
Output terminal(–)  
Output terminal(+)  
Output voltage  
adjustable potentiometer  
LED  
2
1
CN4  
Connector for  
Remote ON/OFF (option)  
19  
[0.75]  
96±0.5  
[3.78]  
14±1.5  
[0.55]  
12.5max  
129  
[0.49]  
[5.08]  
15.3±1.5(LED)  
[0.6]  
11.6±1.5(potentiometer)  
[0.46]  
4
[0.16]  
121  
[4.76]  
Tolerance : 1 [ 0.04]  
Weight  
PCB Material/thickness  
Chassis material Aluminum  
Cover material : Electric galvanizing steel board  
Dimensions in mm, [ ]=inches  
Mounting torque : 0.49N m max  
-
Screw tightening torque : M3.5 1.0N-m max  
Connect the input FG to safety earth ground.  
: 600g max  
:
CEM-3 / 1.6mm [0.06inches]  
:
48  
[1.89]  
70±0.5  
[2.76]  
3-M3  
Mounting hole  
April17, 2018  
PLA-11  
Ordering information  
AC-DC Power Supplies Enclosed Type  
PL  
A
300  
F
-O -O  
5 6  
PLA300F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-06-472  
R
*7  
6Optional  
C: with Coating  
G: Low leakage current  
V : External potentiometer for  
output voltage adjustment  
U: Low input voltage stop  
(Complies with SEMI F-47)  
R : Remote on/off  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
(Required external power source)  
F4: Low speed fan  
T2: Horizontal terminal block  
(non-screw-hold type)  
See 5.1 in Instruction Manual.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
SPECIFICATIONS  
MODEL  
PLA300F-5  
PLA300F-12  
PLA300F-15  
PLA300F-24  
PLA300F-36  
PLA300F-48  
*3  
VOLTAGE[V]  
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)  
ACIN 100V 3.1typ (Io=90%)  
3.4typ (Io=90%)  
ACIN 115V 3.0typ (Io=100%) 3.3typ (Io=100%)  
ACIN 230V 1.5typ (Io=100%) 1.7typ (Io=100%)  
50 / 60 (47 - 63)  
CURRENT[A]  
FREQUENCY[Hz]  
EFFICIENCY[%]  
ACIN 100V 73typ (Io=90%)  
ACIN 115V 74typ (Io=100%)  
ACIN 230V 77typ (Io=100%)  
ACIN 100V 0.98typ (Io=90%)  
ACIN 115V 0.98typ (Io=100%)  
ACIN 230V 0.95typ (Io=100%)  
78typ (Io=90%)  
78typ (Io=100%)  
81typ (Io=100%)  
79typ (Io=90%)  
80typ (Io=100%)  
83typ (Io=100%)  
81typ (Io=90%)  
82typ (Io=100%)  
86typ (Io=100%)  
81typ (Io=90%)  
82typ (Io=100%)  
86typ (Io=100%)  
82typ (Io=90%)  
83typ (Io=100%)  
86typ (Io=100%)  
INPUT  
POWER FACTOR  
ACIN 100V 20typ (Io=90%) Ta=25Cat cold start  
INRUSH CURRENT[A] ACIN 115V 20typ (Io=100%) Ta=25Cat cold start  
ACIN 230V 40typ (Io=100%) Ta=25Cat cold start  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
5
12  
15  
24  
36  
48  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
CURRENT[A]  
WATTAGE[W]  
ACIN 115V-264V 50  
25  
20  
12.5  
8.4  
6.3  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
ACIN 115V-264V 250  
300  
300  
300  
302.4  
302.4  
*
4
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
40max  
48max  
100max  
120max  
160max  
150max  
180max  
120max  
180max  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
150max  
150max  
160max  
200max  
240max  
360max  
440max  
144max  
192max  
300max  
150max  
400max  
200max  
500max  
480max  
600max  
192max  
*
4
0 to +50C 80max  
-10 to 0C 140max  
0 to +50C 120max  
-10 to 0C 160max  
0 to +50C 50max  
-10 to +50C 75max  
RIPPLE[mVp-p]  
*1  
*1  
OUTPUT  
RIPPLE NOISE[mVp-p]  
TEMPERATURE REGULATION[mV]  
*
2
20max  
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
300typ (ACIN 115V, Io=100%)  
20typ (ACIN 115V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50  
10.80 to 13.20  
12.00 to 12.48  
13.50 to 16.50  
15.00 to 15.60  
21.60 to 26.40  
24.00 to 24.96  
32.40 to 39.60  
36.00 to 37.44  
43.20 to 52.80  
48.00 to 49.92  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
5.00 to 5.15  
Works over 105% of rating and recovers automatically  
13.80 to 16.80 17.25 to 21.00  
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00  
27.60 to 33.60  
41.40 to 50.40  
55.20 to 67.20  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
LED (Green)  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
INPUT-FG  
OUTPUT RC-FG  
OUTPUT-RC  
Optional (Required external power source. Option -R)  
*
10  
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)  
-20 to +70C(Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max  
ISOLATION  
*
*
10  
10  
*
5
OPERATING TEMP.,HUMID.AND ALTITUDE  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axes  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
Complies with IEC61000-3-2 class A  
SAFETY AND  
NOISE  
REGULATIONS  
*
9
April17, 2018  
PLA-12  
PLA300F  
SPECIFICATIONS  
CASE SIZE/WEIGHT  
COOLING METHOD  
102X41X190mm [4.02X1.61X7.48 inches] (Excluding terminal block and screw) (WXHXD) / 1.0kg max  
Forced cooling (internal fan)  
OTHERS  
*
*
8
6
WARRANTY WARRANTY  
5 years (subject to the operating conditions)  
*1 This is the result of measurement of the testing board with capacitors of  
22mF and 0.1mF placed at 150 mm from the output terminals by a 20  
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken  
RM103.  
*4 Consult us about dynamic load and input response.  
*5 See 3.2 in Instruction Manual.  
*
Do not use the power supply in overcurrent conditions or in unspecified  
input voltage ranges. Otherwise the internal components may be  
damaged.  
*6 See 3.3 in Instruction Manual for more details.  
*7 Consult us about safety agency approvals for the models with optional functions.  
*8 The fan speed slows down at no load.  
*
*
Parallel operation is not possible with this mode.  
Sound noise may be heard from the power supply when used for  
pulse load.  
See 1.6 of Instruction Manual for more details.  
*2 Drift is the change in DC output for an eight hour period after a half-hour  
warm-up at 25C.  
*9 Consult us about other classes.  
*10 The RC terminal is added to option –R models. The RC terminal is  
isolated from input, output, and FG.  
*3 Output power derating is required. As for DC input, consult us for advice.  
Features  
-
-
-
-
-
-
-
-
Cost-effective  
Longer life (see Instruction Manual)  
Low profile (meets 1U height = 41 mm or 1.61 inches)  
Wide operating temperature range (-20 to +70 see instruction manual)  
Screw hold type terminal block  
Slow fan speed at no load  
Many optional functions  
Complies with SEMI F-47 (-U option, see Instruction Manual for details)  
Block diagram  
FUSE  
250V 10A  
INRUSH  
CURRENT  
LIMIT  
NOISE  
FILTER  
RECTIFIER  
AC IN 85 - 264V  
FG  
CURRENT  
SENSING  
CONTROL  
BOOSTER  
INDUCTOR  
RECTIFIER  
AND  
FILTER  
CURRENT  
SENSING  
CONTROL  
OVER VOLTAGE  
PROTECTION  
INVERTER  
CONTROL  
RECTIFIER  
AND  
FILTER  
INVERTER  
DC OUT  
THERMAL  
PROTECTION  
CONTROL  
FAN  
External view  
The external size of –V option, –R option, and –T2 option models is different from the standard model. See “5. Options and Others” in  
Instruction Manual for more details.  
1.5 (potentiometer)  
13.1  
[0.52]  
1.5 (LED)  
16.8  
[0.66]  
4-M4  
Mounting Hole  
(Bottom side)  
LED  
Name plate  
20max  
[0.79max]  
Output voltage  
adjustable potentiometer  
Output terminal (+)  
Output terminal (–)  
FG(  
)
AC(N)  
AC(L)  
M4  
0.5  
12.5  
[0.49]  
150  
[5.91]  
1.5  
16.6  
[0.65]  
5max  
[0.2max]  
190  
[7.48]  
Tolerance : 1 [ 0.04]  
Weight  
PCB Material/thickness  
Chassis material Aluminum  
Case material : Electric galvanizing steel board  
Dimensions in mm, [ ]=inches  
Mounting torque : 1.2N m max  
Screw tightening torque : 1.6N m max  
Connect the input FG to safety earth ground.  
: 1.0kg max  
AIR FLOW  
:
CEM-3 / 1.6mm [0.06inches]  
:
0.5  
19.5  
[0.77]  
150  
[5.91]  
4-M4  
Mounting Hole  
April17, 2018  
PLA-13  
Ordering information  
AC-DC Power Supplies Enclosed Type  
PL  
A
600  
F
-O -O  
5 6  
PLA600F  
1
2
3
4
1Series name  
2Single output  
3Output wattage  
4Universal input  
5Output voltage  
Example recommended EMI/EMC filter  
NAC-16-472  
R
*7  
6Optional  
C : with Coating  
G: Low leakage current  
V : External potentiometer for  
output voltage adjustment  
U : Low input voltage stop  
(Complies with SEMI F-47)  
W: Parallel operation,  
LV alarm Remote sensing  
R : Remote on/off  
High voltage pulse noise type : NAP series  
Low leakage current type : NAM series  
*
A higher current rating EMI/EMC filter  
may be recommended in view of the  
other devices that could be connected  
in parallel with the power supply.  
(Required external power source)  
F4: Low speed fan  
T2: Horizontal terminal block  
(non-screw-hold type)  
See 5.1 in Instruction Manual.  
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.  
*Please consider “PJA600F-5” about 5V output.  
SPECIFICATIONS  
MODEL  
PLA600F-12  
PLA600F-15  
PLA600F-24  
PLA600F-36  
PLA600F-48  
*4  
VOLTAGE[V]  
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)  
ACIN 100V 6.7typ (Io=90%)  
CURRENT[A]  
ACIN 115V 6.5typ (Io=100%)  
ACIN 230V 3.2typ (Io=100%)  
50 / 60 (47 - 63)  
FREQUENCY[Hz]  
EFFICIENCY[%]  
ACIN 100V 81typ (Io=90%)  
ACIN 115V 81typ (Io=100%)  
ACIN 230V 84typ (Io=100%)  
ACIN 100V 0.98typ (Io=90%)  
ACIN 115V 0.98typ (Io=100%)  
ACIN 230V 0.95typ (Io=100%)  
81typ (Io=90%)  
81typ (Io=100%)  
84typ (Io=100%)  
84typ (Io=90%)  
84typ (Io=100%)  
88typ (Io=100%)  
85typ (Io=90%)  
85typ (Io=100%)  
88typ (Io=100%)  
85typ (Io=90%)  
85typ (Io=100%)  
88typ (Io=100%)  
INPUT  
POWER FACTOR  
ACIN 100V 20/40typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)  
INRUSH CURRENT[A] ACIN 115V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)  
ACIN 230V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)  
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
1.5max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)  
12 15 24 36  
48  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
CURRENT[A]  
WATTAGE[W]  
ACIN 115V-264V 50  
40  
25  
16.7  
12.5  
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)  
ACIN 115V-264V 600  
600  
600  
601.2  
600  
*
8
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
48max  
60max  
120max  
120max  
160max  
150max  
180max  
150max  
180max  
60max  
96max  
150max  
120max  
160max  
150max  
180max  
240max  
290max  
96max  
144max  
150max  
150max  
160max  
200max  
240max  
360max  
440max  
144max  
192max  
300max  
150max  
400max  
200max  
500max  
480max  
600max  
192max  
*
8
100max  
0 to +50C 120max  
-20 to 0C 160max  
0 to +50C 150max  
-20 to 0C 180max  
0 to +50C 120max  
-20 to +50C 180max  
RIPPLE[mVp-p]  
*1  
*1  
OUTPUT  
RIPPLE NOISE[mVp-p]  
TEMPERATURE REGULATION[mV]  
*
2
48max  
DRIFT[mV]  
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
300typ (ACIN 115V, Io=100%)  
20typ (ACIN 115V, Io=100%)  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20  
13.50 to 16.50  
15.00 to 15.60  
21.60 to 26.40  
24.00 to 24.96  
32.40 to 39.60  
36.00 to 37.44  
43.20 to 52.80  
48.00 to 49.92  
OUTPUT VOLTAGE SETTING[V]  
OVERCURRENT PROTECTION  
12.00 to 12.48  
Works over 105% of rating and recovers automatically  
17.25 to 21.00 27.60 to 33.60  
OVERVOLTAGE PROTECTION[V] 13.80 to 16.80  
41.40 to 50.40  
55.20 to 67.20  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
LED (Green)  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT RC  
INPUT-FG  
OUTPUT RC-FG  
OUTPUT-RC  
Optional (Option -W)  
Optional (Required external power source. Option -R)  
*
3
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)  
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)  
ISOLATION  
*
*
*
3
3
5
OPERATING TEMP.,HUMID.AND ALTITUDE  
-20 to +70C(Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max  
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max  
ENVIRONMENT  
2
VIBRATION  
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes  
2
IMPACT  
196.1m/s (20G), 11ms, once each X, Y and Z axes  
AGENCY APPROVALS  
CONDUCTED NOISE  
HARMONIC ATTENUATOR  
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN  
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B  
Complies with IEC61000-3-2 class A  
SAFETY AND  
NOISE  
REGULATIONS  
*
10  
April17, 2018  
PLA-14  
PLA600F  
SPECIFICATIONS  
CASE SIZE/WEIGHT  
COOLING METHOD  
120X61X215mm [4.72X2.40X8.46 inches] (Excluding terminal block and screw) (WXHXD) / 2.0kg max  
Forced cooling (internal fan)  
OTHERS  
*
*
9
6
WARRANTY WARRANTY  
5 years (subject to the operating conditions)  
*1 This is the result of measurement of the testing board with capacitors of *3 The RC terminal is added to option –R models. The RC terminal is  
*9 The fan speed slows down at no load.  
*10 Consult us about other classes.  
22mF and 0.1mF placed at 150 mm from the output terminals by a 20  
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken  
RM103.  
isolated from input, output, and FG.  
*4 As for DC input, consult us for advice.  
*
Do not use the power supply in overcurrent conditions or in unspecified  
input voltage ranges. Otherwise the internal components may be damaged.  
Parallel operation is allowed for PLA600F models with the –W option only.  
Sound noise may be heard from the power supply when used for pulse load.  
*5 Output power derating is required. See 3.2 in Instruction Manual.  
*6 See 3.3 in Instruction Manual for more details.  
See 1.6 of Instruction Manual for more details.  
*
*
*2 Drift is the change in DC output for an eight hour period after a half-hour *7 Consult us about safety agency approvals for the models with optional functions.  
warm-up at 25C.  
*8 Consult us about dynamic load and input response.  
Features  
-
-
-
-
Cost-effective  
-
-
-
-
Screw hold type terminal block  
Slow fan speed at no load  
Longer life (see Instruction Manual)  
Low profile (meets 2U height = 61 mm or 2.40 inches)  
Wide operating temperature range (-20 to +70 see  
instruction manual)  
Many optional functions  
Complies with SEMI F-47 (-U option, see Instruction  
Manual for details)  
Block diagram  
BOOSTER  
INDUCTOR  
FUSE  
250V 16A  
INRUSH  
CURRENT  
LIMIT  
RECTIFIER  
AND  
FILTER  
NOISE  
CURRENT  
SENSING  
RECTIFIER  
AC IN 85 - 264V  
FILTER  
INVERTER  
CONTROL  
FG  
CURRENT  
SENSING  
RC (-R)  
External source  
THERMAL  
PROTECTION  
PARALLEL-OPERATION  
CIRCUIT  
CONTROL  
INVERTER  
CONTROL  
Current balance (-W)  
LV alarm (-W)  
OVER VOLTAGE  
PROTECTION  
DETECTING  
OUTPUT VOLTAGE  
RECTIFIER  
AND  
DC OUT  
FILTER  
CONTROL  
FAN  
External view  
The external size of –V option, –W option, –R option, and –T2 option is different from the standard model. See “5. Options and Others”  
in Instruction Manual for more details.  
26.6 1.5  
[1.05]  
16.6 1.5  
[0.65]  
15.8 1.5 (LED)  
[0.62]  
Output  
terminal cover  
12.1 1.5 (potentiometer)  
4-M4  
[0.48]  
Mounting Hole  
(Bottom sides)  
M4  
(+V,-V)  
Name plate  
21max  
[0.83max]  
LED  
Output voltage  
adjustable potentiometer  
Output terminal (+)  
Output terminal (-)  
FG(  
)
AC(N)  
AC(L)  
M3.5  
(AC,FG)  
15.5 1.5  
[0.61]  
35  
150 0.5  
[5.91]  
[1.38]  
215  
3max  
[8.46]  
[0.12max]  
Tolerance : 1 [ 0.04]  
Weight  
PCB Material/thickness  
Chassis material  
Case material Electric galvanizing steel board  
Dimensions in mm, [ ]=inches  
Mounting torque 1.5N-m max  
Screw tightening torque M3.5 0.8N-m max  
M4 1.6N-m max  
Connect the input FG to safety earth ground.  
: 2.0kg max  
AIR FLOW  
:
FR-4 / 1.6mm [0.06inches]  
:
Electric galvanizing steel board  
:
:
35  
150 0.5  
[5.91]  
:
[1.38]  
4-M4  
Mounting Hole  
April17, 2018  
PLA-15  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY