PLA15F-15 [COSEL]
AC/DC CONVERTER 15V;型号: | PLA15F-15 |
厂家: | COSEL CO., LTD. |
描述: | AC/DC CONVERTER 15V |
文件: | 总14页 (文件大小:1159K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Ordering information
AC-DC Power Supplies Enclosed Type
PL
A
15
F
-O -O
5 6
PLA15F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-04-472
R
*7
6Optional
C: with Coating
J : Connector interface
T : Vertical terminal block
-NO: with DIN rail
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PLA15F-5
PLA15F-12
PLA15F-15
PLA15F-24
*3
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
ACIN 100V 0.4typ (Io=90%)
VOLTAGE[V]
ACIN 115V 0.4typ (Io=100%)
ACIN 230V 0.25typ (Io=100%)
50 / 60 (47 - 63)
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 72.5typ (Io=90%)
ACIN 115V 73.5typ (Io=100%)
ACIN 230V 75.5typ (Io=100%)
75.5typ (Io=90%)
77.0typ (Io=100%)
78.5typ (Io=100%)
77.0typ (Io=90%)
78.5typ (Io=100%)
79.5typ (Io=100%)
78.0typ (Io=90%)
79.0typ (Io=100%)
80.0typ (Io=100%)
INPUT
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start
ACIN 115V 16typ (Io=100%) Ta=25Cat cold start
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.30max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
5
3
12
15
1
24
1.3
0.7
CURRENT[A]
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
WATTAGE[W]
ACIN 115V-264V 15.0
15.6
15.0
16.8
*
4
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
48max
60max
96max
*
4
100max
120max
160max
240max
150max
180max
300max
120max
150max
48max
120max
120max
160max
240max
150max
180max
300max
150max
180max
60max
150max
120max
160max
280max
150max
180max
320max
240max
290max
96max
0 to +50C 80max
-10 to 0C 140max
Io=0 to 35% 160max
0 to +50C 120max
-10 to 0C 160max
Io=0 to 35% 240max
0 to +50C 50max
-10 to +50C 60max
RIPPLE[mVp-p]
*1
OUTPUT
RIPPLE NOISE[mVp-p] *1
TEMPERATURE REGULATION[mV]
*
2
20max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
200typ (ACIN 115V, Io=100%) *Start-up time is 700 ms typ for less than 1 minute of applying input again from turning off the input voltage.
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50
10.80 to 13.20
12.00 to 12.48
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
5.00 to 5.15
Works over 105% of rating and recovers automatically
13.80 to 16.80
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00
17.25 to 21.00
27.60 to 33.60
PROTECTION
CIRCUIT AND
OTHERS
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
LED (Green)
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
INPUT-FG
ISOLATION
OUTPUT-FG
*
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
8
April17, 2018
PLA-2
PLA15F
SPECIFICATIONS
CASE SIZE/WEIGHT
38X80X73mm [1.50X3.15X2.87 inches] (Excluding terminal block and screw) (WXHXD) / 250g max
OTHERS
COOLING METHOD
Convection
*
6
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150
mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-
Giken RM103.
*5 Output power derating is required. See 3.2 in Instruction Manual.
*6 See 3.3 in Instruction Manual for more details.
*7 Consult us about safety agency approvals for the models with optional functions.
*8 Consult us about other classes.
See 1.6 of Instruction Manual for more details.
When the load factor is 0 - 35%, the switching power loss is reduced by burst operation, which will
cause ripple and ripple noise to go beyond the specifications.
*
Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.
Otherwise the internal components may be damaged.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 As for DC input, consult us for advice.
*
*
Parallel operation is not possible with this mode.
Sound noise may be heard from the power supply when used for pulse load.
*4 Consult us about dynamic load and input response. Measure the output voltage by using the average mode
of the tester to deal with the burst operation at 35% load or less.
Features
-
-
-
-
Compact design (Depth: 73mm 2.87inches)
Low power consumption (1.0W typ AC240Vin, no load at standard model)
UL508 approved (Except option -J), and complies with SEMI F47
Various connection interface options (vertical terminal [-T], AMP connector [-J])
Block diagram
FUSE
AC250V 2.5A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
NOISE
FILTER
AC IN 85 - 264V
FG
TRANSFORMER
RECTIFIER
AND
CONTROL
INVERTER
DC OUT
FILTER
OVER CURRENT
SENSING
Photocoupler
Photocoupler
CONTROL
OVER VOLTAGE
PROTECTION
External view
2-M3
Point A
Name plate
TB1
Mounting hole
(Bottom side)
M3.5
AC(L)
AC(N)
FG(
Output terminal(-)
Output terminal(+)
)
Output voltage
adjustable potentiometer
Terminal cover
LED
±0.5
18
35.5
[1.4]
[0.71]
±1.5
15.3
[0.6]
(LED)
12.5max
[0.49]
73
[2.87]
14 ±1.5
[0.55]
±1.5
11.6
(Potentiometer)
[0.46]
¶ Tolerance : 1 [ 0.04]
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material
Case material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
: 250g max
:
CEM-3 / 1.6mm [0.06inches]
:
Electric galvanizing steel board
2-M3
±0.5
46
[1.81]
18
[0.71]
Mounting torque
Screw tightening torque : 1.0N-m max
: 0.6N m max
-
Mounting hole
April17, 2018
PLA-3
Ordering information
AC-DC Power Supplies Enclosed Type
PL
A
30
F
-O -O
5 6
PLA30F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-04-472
R
*7
6Optional
C: with Coating
J : Connector interface
T : Vertical terminal block
-NO: with DIN rail
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PLA30F-5
PLA30F-12
PLA30F-15
PLA30F-24
*3
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
ACIN 100V 0.7typ (Io=90%)
VOLTAGE[V]
ACIN 115V 0.7typ (Io=100%)
ACIN 230V 0.4typ (Io=100%)
50 / 60 (47 - 63)
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 73.0typ (Io=90%)
ACIN 115V 74.0typ (Io=100%)
ACIN 230V 77.0typ (Io=100%)
80.0typ (Io=90%)
80.5typ (Io=100%)
81.0typ (Io=100%)
81.0typ (Io=90%)
81.5typ (Io=100%)
82.0typ (Io=100%)
82.5typ (Io=90%)
83.0typ (Io=100%)
83.5typ (Io=100%)
INPUT
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start
ACIN 115V 16typ (Io=100%) Ta=25Cat cold start
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start
INRUSH CURRENT[A]
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.65max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
5
6
12
15
2
24
2.5
1.3
CURRENT[A]
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
WATTAGE[W]
ACIN 115V-264V 30.0
30.0
30.0
31.2
*
4
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
*
4
0 to +50C 80max
-10 to 0C 140max
0 to +50C 120max
-10 to 0C 160max
0 to +50C 50max
-10 to +50C 60max
RIPPLE[mVp-p]
*1
OUTPUT
RIPPLE NOISE[mVp-p] *1
TEMPERATURE REGULATION[mV]
*
2
20max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
150typ (ACIN 115V, Io=100%)
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50
10.80 to 13.20
12.00 to 12.48
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
5.00 to 5.15
Works over 105% of rating and recovers automatically
13.80 to 16.80
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00
17.25 to 21.00
27.60 to 33.60
PROTECTION
CIRCUIT AND
OTHERS
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
LED (Green)
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
INPUT-FG
ISOLATION
OUTPUT-FG
*
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
8
April17, 2018
PLA-4
PLA30F
SPECIFICATIONS
CASE SIZE/WEIGHT
38X80X88mm [1.50X3.15X3.46 inches] (Excluding terminal block and screw) (WXHXD) / 330g max
OTHERS
COOLING METHOD
Convection
*
6
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150
mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-
Giken RM103.
*7 Consult us about safety agency approvals for the models with optional functions.
*8 Consult us about other classes.
*
Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.
Otherwise the internal components may be damaged.
See 1.6 of Instruction Manual for more details.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 As for DC input, consult us for advice.
*
*
Parallel operation is not possible with this mode.
Sound noise may be heard from the power supply when used for pulse load.
*4 Consult us about dynamic load and input response.
*5 Output power derating is required. See 3.2 in Instruction Manual.
*6 See 3.3 in Instruction Manual for more details.
Features
-
-
-
Compact design (Depth: 88mm 3.46inches)
UL508 approved (Except option -J), and complies with SEMI F47
Various connection interface options (vertical terminal [-T], AMP connector [-J])
Block diagram
FUSE
AC250V 3.15A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
NOISE
FILTER
AC IN 85 - 264V
FG
TRANSFORMER
RECTIFIER
AND
CONTROL
INVERTER
DC OUT
FILTER
OVER CURRENT
SENSING
Photocoupler
Photocoupler
CONTROL
OVER VOLTAGE
PROTECTION
External view
2-M3
Point A
Name plate
Mounting hole
TB1
(Bottom side)
M3.5
AC(L)
AC(N)
FG(
Output terminal(
Output terminal(+)
)
-)
Output voltage
adjustable potentiometer
Terminal cover
LED
±0.5
19
62.5
[2.46]
[0.75]
15.3 ±1.5
[0.6]
12.5max
[0.49]
88
[3.46]
(LED)
14 ±1.5
[0.55]
(Potentiometer)
11.6±1.5
[0.46]
¶ Tolerance : 1 [ 0.04]
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material Electric galvanizing steel board
Case material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
: 330g max
:
CEM-3 / 1.6mm [0.06inches]
:
38
[1.5]
41 ±0.5
[1.61]
Mounting torque
Screw tightening torque : 1.0N-m max
: 0.6N m max
-
2-M3
Mounting hole
April17, 2018
PLA-5
Ordering information
AC-DC Power Supplies Enclosed Type
PL
A
50
F
-O -O
5 6
PLA50F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-04-472
R
*7
6Optional
C: with Coating
J : Connector interface
T : Vertical terminal block
-NO: with DIN rail
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PLA50F-5
PLA50F-12
PLA50F-15
PLA50F-24
*3
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
VOLTAGE[V]
ACIN 100V 0.6typ (Io=90%)
0.7typ (Io=90%)
0.7typ (Io=100%)
0.4typ (Io=100%)
CURRENT[A]
ACIN 115V 0.6typ (Io=100%)
ACIN 230V 0.3typ (Io=100%)
50 / 60 (47 - 63)
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 74.5typ (Io=90%)
ACIN 115V 75.0typ (Io=100%)
ACIN 230V 76.5typ (Io=100%)
ACIN 100V 0.97typ (Io=90%)
ACIN 115V 0.97typ (Io=100%)
ACIN 230V 0.85typ (Io=100%)
80.0typ (Io=90%)
80.5typ (Io=100%)
82.0typ (Io=100%)
0.98typ (Io=90%)
0.98typ (Io=100%)
0.87typ (Io=100%)
80.0typ (Io=90%)
80.5typ (Io=100%)
82.0typ (Io=100%)
81.5typ (Io=90%)
82.0typ (Io=100%)
84.0typ (Io=100%)
INPUT
POWER FACTOR
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start
INRUSH CURRENT[A] ACIN 115V 16typ (Io=100%) Ta=25Cat cold start
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
5
8
12
15
24
4.3
3.5
2.2
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
WATTAGE[W]
ACIN 115V-264V 40.0
51.6
52.5
52.8
*
4
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
48max
100max
120max
160max
150max
180max
120max
150max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
*
4
0 to +45C 80max
-10 to 0C 140max
0 to +45C 120max
-10 to 0C 160max
0 to +45C 50max
-10 to +45C 60max
RIPPLE[mVp-p]
*1
OUTPUT
RIPPLE NOISE[mVp-p] *1
TEMPERATURE REGULATION[mV]
*
2
20max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
350typ (ACIN 115V, Io=100%)
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50
10.80 to 13.20
12.00 to 12.48
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
5.00 to 5.15
Works over 105% of rating and recovers automatically
13.80 to 16.80
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00
17.25 to 21.00
27.60 to 33.60
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
Not provided
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)
5
-20 to +70C, 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
ISOLATION
OUTPUT-FG
*
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
8
April17, 2018
PLA-6
PLA50F
SPECIFICATIONS
CASE SIZE/WEIGHT
38X80X99mm [1.50X3.15X3.90 inches] (Excluding terminal block and screw) (WXHXD) / 400g max
OTHERS
COOLING METHOD
Convection
*
6
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150
mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-
Giken RM103.
*7 Consult us about safety agency approvals for the models with optional functions.
*8 Consult us about other classes.
*
Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges.
Otherwise the internal components may be damaged.
See 1.6 of Instruction Manual for more details.
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 As for DC input, consult us for advice.
*
*
Parallel operation is not possible with this mode.
Sound noise may be heard from the power supply when used for pulse load.
*4 Consult us about dynamic load and input response.
*5 Output power derating is required. See 3.2 in Instruction Manual.
*6 See 3.3 in Instruction Manual for more details.
Features
-
-
-
Compact design (Depth: 99mm 3.90inches)
UL508 approved (Except option -J), and complies with SEMI F47
Various connection interface options (vertical terminal [-T], AMP connector [-J])
Block diagram
FUSE
AC250V 2.5A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
AC IN 85 - 264V
FG
RECTIFIER
TRANSFORMER
BOOSTER
INDUCTOR
CURRENT
SENSING
RECTIFIER
AND
CONTROL
INVERTER
DC OUT
RECTIFIER
AND
FILTER
FILTER
Photocoupler
Photocoupler
OVER CURRENT
SENSING
INVERTER
CONTROL
CONTROL
OVER VOLTAGE
PROTECTION
External view
2-M3
Point A
Mounting hole
Name plate
TB1
(Bottom side)
M3.5
AC(L)
AC(N)
FG(
Output terminal(
Output terminal(+)
)
-
)
Output voltage
adjustable potentiometer
Terminal cover
LED
19
[0.75]
76 ±0.5
[2.99]
15.3 ±1.5
[0.6]
12.5max
[0.49]
99
[3.9]
(LED)
14 ±1.5
[0.55]
(Potentiometer)
11.6±1.5
[0.46]
¶ Tolerance : 1 [ 0.04]
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material Electric galvanizing steel board
Case material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
: 400g max
:
CEM-3 / 1.6mm [0.06inches]
:
±0.5
52
[2.05]
38
[1.5]
2-M3
Mounting torque
Screw tightening torque : 1.0N-m max
: 0.6N m max
-
Mounting hole
April17, 2018
PLA-7
Ordering information
AC-DC Power Supplies Enclosed Type
PL
A
100
F
-O -O
5 6
PLA100F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-04-472
R
*7
6Optional
C: with Coating
R: Remote on/off
(Required external
power source)
J : Connector interface
T : Vertical terminal block
-NO: with DIN rail
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
*Please consider "PBA100F-5-N" about 5V output with case cover.
MODEL
PLA100F-12
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
ACIN 100V 1.2typ (Io=90%)
PLA100F-15
PLA100F-24
PLA100F-36
PLA100F-48
*3
VOLTAGE[V]
CURRENT[A]
ACIN 115V 1.1typ (Io=100%)
ACIN 230V 0.6typ (Io=100%)
50 / 60 (47 - 63)
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 82typ (Io=90%)
ACIN 115V 82typ (Io=100%)
ACIN 230V 85typ (Io=100%)
ACIN 100V 0.98typ (Io=90%)
ACIN 115V 0.98typ (Io=100%)
83typ (Io=90%)
83typ (Io=100%)
86typ (Io=100%)
85typ (Io=90%)
85typ (Io=100%)
88typ (Io=100%)
86typ (Io=90%)
86typ (Io=100%)
89typ (Io=100%)
86typ (Io=90%)
86typ (Io=100%)
89typ (Io=100%)
INPUT
POWER FACTOR
ACIN 230V 0.95typ (Io=100%) *Power factor correction is stopped at AC250V or more.
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start
INRUSH CURRENT[A] ACIN 115V 16typ (Io=100%) Ta=25Cat cold start
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
12 15 24 36
48
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
CURRENT[A]
ACIN 115V-264V 8.4
6.7
4.3
2.8
2.1
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
WATTAGE[W]
ACIN 115V-264V 100.8
100.5
103.2
100.8
100.8
*
4
48max
LINE REGULATION[mV]
60max
120max
96max
150max
144max
150max
192max
300max
Io=30 to 100% 100max
LOAD REGULATION
*
4
[mV]
Io=0 to 30% Burst operation (Please contact us about detail)
0 to +40C 120max
-10 to 0C 160max
Io=0 to 30% 500max
0 to +40C 150max
-10 to 0C 180max
Io=0 to 30% 600max
0 to +40C 120max
-10 to +40C 180max
120max
160max
500max
150max
180max
600max
150max
180max
60max
120max
160max
500max
150max
180max
600max
240max
290max
96max
150max
200max
500max
200max
240max
600max
360max
440max
144max
150max
400max
500max
200max
500max
600max
480max
600max
192max
RIPPLE[mVp-p]
*1
Io: load factor
OUTPUT
RIPPLE NOISE[mVp-p]
*1
Io: load factor
TEMPERATURE REGULATION[mV]
*
2
48max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
500typ (ACIN 115V, Io=100%) Ta=25C
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
32.40 to 39.60
36.00 to 37.44
43.20 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
12.00 to 12.48
Works over 105% of rating and recovers automatically
17.25 to 21.00 27.60 to 33.60
OVERVOLTAGE PROTECTION[V] 13.80 to 16.80
41.40 to 50.40
54.00 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
INPUT-FG
Optional (Required external power source. Option -R)
*
9
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
ISOLATION
*
*
9
9
OUTPUT RC-FG
OUTPUT-RC
*
5
-20 to +70C(Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
8
April17, 2018
PLA-8
PLA100F
SPECIFICATIONS
CASE SIZE/WEIGHT
41X97X109mm [1.61X3.82X4.29 inches] (Excluding terminal block and screw) (WXHXD) / 500g max
OTHERS
COOLING METHOD
Convection
*
6
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with
capacitors of 22mF and 0.1mF placed at 150 mm from the
output terminals by a 20 MHz oscilloscope or a ripple-noise meter
equivalent to Keisoku-Giken RM103.
hour warm-up at 25C.
*9 The RC terminal is added to option –R models.The RC terminal is
*3 As for DC input, consult us for advice.
isolated from input, output, and FG.
*4 Consult us about dynamic load and input response. Measure the output *
voltage by using the average mode of the tester to deal with the burst
operation at 30% load or less.
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be
damaged.
See 1.6 of Instruction Manual for more details.
When the load factor is 0 - 30%, the switching power loss is
reduced by burst operation, which will cause ripple and ripple
noise to go beyond the specifications.
*5 Output power derating is required. See 3.2 in Instruction Manual.
*6 See 3.3 in Instruction Manual for more details.
*
*
Parallel operation is not possible with this mode.
Sound noise may be heard from the power supply when used for
pulse load.
*7 Consult us about safety agency approvals for the models with optional functions.
*8 Consult us about other classes.
*2 Drift is the change in DC output for an eight hour period after a half-
Features
-
-
-
-
-
Compact design (Depth: 109mm 4.29inches)
High efficiency (88%typ PLA100F-24, AC230Vin, 100% load)
Low power consumption (1.5W typ AC240Vin, no load at standard model)
UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1)
Various connection interface options (vertical terminal [-T], AMP connector [-J])
Block diagram
FUSE
250V 3.15A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
FG
RC(-R)
CURRENT
SENSING
BOOSTER
INDUCTOR
EXTERNAL
SOURCE
CONTROL
RECTIFIER
AND
FILTER
CURRENT
SENSING
OVER VOLTAGE
PROTECTION
INVERTER
RECTIFIER
AND
INVERTER
DC OUT
FILTER
CONTROL
External view
The external size of –R option, –J option, –N1 option and –T option models is different from the standard model. See “5. Options and
Others” in Instruction Manual for more details.
2-M3
Name plate
Mounting hole
(Bottom side)
M3.5
AC(L)
Terminal cover
AC(N)
Point A
FG(
)
Output terminal(–)
Output terminal(+)
Output voltage
adjustable potentiometer
LED
2
1
CN4
Connector for
Remote ON/OFF (option)
19.5
[0.77]
76±0.5
[2.99]
109
14±1.5
[0.55]
12.5max
[0.49]
15.3±1.5 (LED)
[0.6]
[4.29]
11.6±1.5 (potentiometer)
[0.46]
4
[0.16]
101
[3.98]
¶ Tolerance : 1 [ 0.04]
¶
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material Aluminum
Cover material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque : 0.49N m max
-
Screw tightening torque : M3.5 1.0N-m max
Connect the input FG to safety earth ground.
: 500g max
:
CEM-3 / 1.6mm [0.06inches]
:
3-M3
Mounting hole
33.5
[1.32]
66.5±0.5
[2.62]
April17, 2018
PLA-9
Ordering information
AC-DC Power Supplies Enclosed Type
PL
A
150
F
-O -O
5 6
PLA150F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-04-472
R
*7
6Optional
C: with Coating
R: Remote on/off
(Required external
power source)
J : Connector interface
T : Vertical terminal block
-NO: with DIN rail
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
*Please consider "PBA150F-5-N" about 5V output with case cover.
MODEL
PLA150F-12
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
ACIN 100V 1.7typ (Io=90%)
PLA150F-15
PLA150F-24
PLA150F-36
PLA150F-48
*3
VOLTAGE[V]
CURRENT[A]
ACIN 115V 1.6typ (Io=100%)
ACIN 230V 0.8typ (Io=100%)
50 / 60 (47 - 63)
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 84typ (Io=90%)
ACIN 115V 84typ (Io=100%)
ACIN 230V 87typ (Io=100%)
ACIN 100V 0.98typ (Io=90%)
ACIN 115V 0.98typ (Io=100%)
84typ (Io=90%)
84typ (Io=100%)
87typ (Io=100%)
87typ (Io=90%)
87typ (Io=100%)
90typ (Io=100%)
87typ (Io=90%)
87typ (Io=100%)
90typ (Io=100%)
87typ (Io=90%)
87typ (Io=100%)
90typ (Io=100%)
INPUT
POWER FACTOR
ACIN 230V 0.95typ (Io=100%) *Power factor correction is stopped at AC250V or more.
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start
INRUSH CURRENT[A] ACIN 115V 16typ (Io=100%) Ta=25Cat cold start
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
12 15 24 36
48
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
10 6.4 4.2
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
CURRENT[A]
ACIN 115V-264V 12.5
3.2
WATTAGE[W]
ACIN 115V-264V 150.0
150.0
153.6
151.2
153.6
*
4
48max
LINE REGULATION[mV]
60max
120max
96max
150max
144max
150max
192max
300max
Io=30 to 100% 100max
LOAD REGULATION
*
4
[mV]
Io=0 to 30% Burst operation (Please contact us about detail)
0 to +40C 120max
-10 to 0C 160max
Io=0 to 30% 500max
0 to +40C 150max
-10 to 0C 180max
Io=0 to 30% 600max
0 to +40C 120max
-10 to +40C 180max
120max
160max
500max
150max
180max
600max
150max
180max
60max
120max
160max
500max
150max
180max
600max
240max
290max
96max
150max
200max
500max
200max
240max
600max
360max
440max
144max
150max
400max
500max
200max
500max
600max
480max
600max
192max
RIPPLE[mVp-p]
*1
Io: load factor
OUTPUT
RIPPLE NOISE[mVp-p]
*1
Io: load factor
TEMPERATURE REGULATION[mV]
*
2
48max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
500typ (ACIN 115V, Io=100%) Ta=25C
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
32.40 to 39.60
36.00 to 37.44
43.20 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
12.00 to 12.48
Works over 105% of rating and recovers automatically
17.25 to 21.00 27.60 to 33.60
OVERVOLTAGE PROTECTION[V] 13.80 to 16.80
41.40 to 50.40
54.00 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
INPUT-FG
Optional (Required external power source. Option -R)
*
9
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
ISOLATION
*
*
9
9
OUTPUT RC-FG
OUTPUT-RC
*
5
-20 to +70C(Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178, UL508 (Except option -J) Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
8
April17, 2018
PLA-10
PLA150F
SPECIFICATIONS
CASE SIZE/WEIGHT
41X97X129mm [1.61X3.82X5.08 inches] (Excluding terminal block and screw) (WXHXD) / 600g max
OTHERS
COOLING METHOD
Convection
*
6
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
hour warm-up at 25C.
*9 The RC terminal is added to option –R models. The RC terminal
*3 As for DC input, consult us for advice.
is isolated from input, output, and FG.
*4 Consult us about dynamic load and input response. Measure the output
voltage by using the average mode of the tester to deal with the burst
operation at 30% load or less.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be
damaged.
See 1.6 of Instruction Manual for more details.
When the load factor is 0 - 30%, the switching power loss is reduced by *5 Output power derating is required. See 3.2 in Instruction Manual.
*
*
Parallel operation is not possible with this mode.
Sound noise may be heard from the power supply when used for
pulse load.
burst operation, which will cause ripple and ripple noise to go beyond
the specifications.
*6 See 3.3 in Instruction Manual for more details.
*7 Consult us about safety agency approvals for the models with optional functions.
*8 Consult us about other classes.
*2 Drift is the change in DC output for an eight hour period after a half-
Features
-
-
-
-
-
Compact design (Depth: 129mm 5.08inches)
High efficiency (90%typ PLA150F-24, AC230Vin, 100% load)
Low power consumption (1.5W typ AC240Vin, no load at standard model)
UL508 approved (Except option -J), and complies with SEMI F47 (see instruction manual 1.1)
Various connection interface options (vertical terminal [-T], AMP connector [-J])
Block diagram
FUSE
250V 4A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
FG
RC(-R)
CURRENT
SENSING
BOOSTER
INDUCTOR
EXTERNAL
SOURCE
CONTROL
RECTIFIER
AND
FILTER
CURRENT
SENSING
OVER VOLTAGE
PROTECTION
INVERTER
RECTIFIER
AND
INVERTER
DC OUT
FILTER
CONTROL
External view
The external size of –R option, –J option, –N1 option and –T option models is different from the standard model. See “5. Options and
Others” in Instruction Manual for more details.
2-M3
Name plate
Mounting hole
(Bottom side)
Point B
M3.5
AC(L)
AC(N)
Terminal cover
Point A
FG(
)
Output terminal(–)
Output terminal(+)
Output voltage
adjustable potentiometer
LED
2
1
CN4
Connector for
Remote ON/OFF (option)
19
[0.75]
96±0.5
[3.78]
14±1.5
[0.55]
12.5max
129
[0.49]
[5.08]
15.3±1.5(LED)
[0.6]
11.6±1.5(potentiometer)
[0.46]
4
[0.16]
121
[4.76]
¶ Tolerance : 1 [ 0.04]
¶
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material Aluminum
Cover material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque : 0.49N m max
-
Screw tightening torque : M3.5 1.0N-m max
Connect the input FG to safety earth ground.
: 600g max
:
CEM-3 / 1.6mm [0.06inches]
:
48
[1.89]
70±0.5
[2.76]
3-M3
Mounting hole
April17, 2018
PLA-11
Ordering information
AC-DC Power Supplies Enclosed Type
PL
A
300
F
-O -O
5 6
PLA300F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-06-472
R
*7
6Optional
C: with Coating
G: Low leakage current
V : External potentiometer for
output voltage adjustment
U: Low input voltage stop
(Complies with SEMI F-47)
R : Remote on/off
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
(Required external power source)
F4: Low speed fan
T2: Horizontal terminal block
(non-screw-hold type)
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PLA300F-5
PLA300F-12
PLA300F-15
PLA300F-24
PLA300F-36
PLA300F-48
*3
VOLTAGE[V]
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
ACIN 100V 3.1typ (Io=90%)
3.4typ (Io=90%)
ACIN 115V 3.0typ (Io=100%) 3.3typ (Io=100%)
ACIN 230V 1.5typ (Io=100%) 1.7typ (Io=100%)
50 / 60 (47 - 63)
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 73typ (Io=90%)
ACIN 115V 74typ (Io=100%)
ACIN 230V 77typ (Io=100%)
ACIN 100V 0.98typ (Io=90%)
ACIN 115V 0.98typ (Io=100%)
ACIN 230V 0.95typ (Io=100%)
78typ (Io=90%)
78typ (Io=100%)
81typ (Io=100%)
79typ (Io=90%)
80typ (Io=100%)
83typ (Io=100%)
81typ (Io=90%)
82typ (Io=100%)
86typ (Io=100%)
81typ (Io=90%)
82typ (Io=100%)
86typ (Io=100%)
82typ (Io=90%)
83typ (Io=100%)
86typ (Io=100%)
INPUT
POWER FACTOR
ACIN 100V 20typ (Io=90%) Ta=25Cat cold start
INRUSH CURRENT[A] ACIN 115V 20typ (Io=100%) Ta=25Cat cold start
ACIN 230V 40typ (Io=100%) Ta=25Cat cold start
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
5
12
15
24
36
48
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
CURRENT[A]
WATTAGE[W]
ACIN 115V-264V 50
25
20
12.5
8.4
6.3
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V 250
300
300
300
302.4
302.4
*
4
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
48max
100max
120max
160max
150max
180max
120max
180max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
*
4
0 to +50C 80max
-10 to 0C 140max
0 to +50C 120max
-10 to 0C 160max
0 to +50C 50max
-10 to +50C 75max
RIPPLE[mVp-p]
*1
*1
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
*
2
20max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
300typ (ACIN 115V, Io=100%)
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50
10.80 to 13.20
12.00 to 12.48
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
32.40 to 39.60
36.00 to 37.44
43.20 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
5.00 to 5.15
Works over 105% of rating and recovers automatically
13.80 to 16.80 17.25 to 21.00
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00
27.60 to 33.60
41.40 to 50.40
55.20 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
INPUT-FG
OUTPUT RC-FG
OUTPUT-RC
Optional (Required external power source. Option -R)
*
10
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
-20 to +70C(Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
ISOLATION
*
*
10
10
*
5
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
9
April17, 2018
PLA-12
PLA300F
SPECIFICATIONS
CASE SIZE/WEIGHT
COOLING METHOD
102X41X190mm [4.02X1.61X7.48 inches] (Excluding terminal block and screw) (WXHXD) / 1.0kg max
Forced cooling (internal fan)
OTHERS
*
*
8
6
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
*4 Consult us about dynamic load and input response.
*5 See 3.2 in Instruction Manual.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be
damaged.
*6 See 3.3 in Instruction Manual for more details.
*7 Consult us about safety agency approvals for the models with optional functions.
*8 The fan speed slows down at no load.
*
*
Parallel operation is not possible with this mode.
Sound noise may be heard from the power supply when used for
pulse load.
See 1.6 of Instruction Manual for more details.
*2 Drift is the change in DC output for an eight hour period after a half-hour
warm-up at 25C.
*9 Consult us about other classes.
*10 The RC terminal is added to option –R models. The RC terminal is
isolated from input, output, and FG.
*3 Output power derating is required. As for DC input, consult us for advice.
Features
-
-
-
-
-
-
-
-
Cost-effective
Longer life (see Instruction Manual)
Low profile (meets 1U height = 41 mm or 1.61 inches)
Wide operating temperature range (-20 to +70 see instruction manual)
Screw hold type terminal block
Slow fan speed at no load
Many optional functions
Complies with SEMI F-47 (-U option, see Instruction Manual for details)
Block diagram
FUSE
250V 10A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
FG
CURRENT
SENSING
CONTROL
BOOSTER
INDUCTOR
RECTIFIER
AND
FILTER
CURRENT
SENSING
CONTROL
OVER VOLTAGE
PROTECTION
INVERTER
CONTROL
RECTIFIER
AND
FILTER
INVERTER
DC OUT
THERMAL
PROTECTION
CONTROL
FAN
External view
The external size of –V option, –R option, and –T2 option models is different from the standard model. See “5. Options and Others” in
Instruction Manual for more details.
1.5 (potentiometer)
13.1
[0.52]
1.5 (LED)
16.8
[0.66]
4-M4
Mounting Hole
(Bottom side)
LED
Name plate
20max
[0.79max]
Output voltage
adjustable potentiometer
Output terminal (+)
Output terminal (–)
FG(
)
AC(N)
AC(L)
M4
0.5
12.5
[0.49]
150
[5.91]
1.5
16.6
[0.65]
5max
[0.2max]
190
[7.48]
¶ Tolerance : 1 [ 0.04]
¶
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material Aluminum
Case material : Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque : 1.2N m max
Screw tightening torque : 1.6N m max
Connect the input FG to safety earth ground.
: 1.0kg max
AIR FLOW
:
CEM-3 / 1.6mm [0.06inches]
:
0.5
19.5
[0.77]
150
[5.91]
4-M4
Mounting Hole
April17, 2018
PLA-13
Ordering information
AC-DC Power Supplies Enclosed Type
PL
A
600
F
-O -O
5 6
PLA600F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-16-472
R
*7
6Optional
C : with Coating
G: Low leakage current
V : External potentiometer for
output voltage adjustment
U : Low input voltage stop
(Complies with SEMI F-47)
W: Parallel operation,
LV alarm Remote sensing
R : Remote on/off
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
(Required external power source)
F4: Low speed fan
T2: Horizontal terminal block
(non-screw-hold type)
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
*Please consider “PJA600F-5” about 5V output.
SPECIFICATIONS
MODEL
PLA600F-12
PLA600F-15
PLA600F-24
PLA600F-36
PLA600F-48
*4
VOLTAGE[V]
AC85 - 264 1f(Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual)
ACIN 100V 6.7typ (Io=90%)
CURRENT[A]
ACIN 115V 6.5typ (Io=100%)
ACIN 230V 3.2typ (Io=100%)
50 / 60 (47 - 63)
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 81typ (Io=90%)
ACIN 115V 81typ (Io=100%)
ACIN 230V 84typ (Io=100%)
ACIN 100V 0.98typ (Io=90%)
ACIN 115V 0.98typ (Io=100%)
ACIN 230V 0.95typ (Io=100%)
81typ (Io=90%)
81typ (Io=100%)
84typ (Io=100%)
84typ (Io=90%)
84typ (Io=100%)
88typ (Io=100%)
85typ (Io=90%)
85typ (Io=100%)
88typ (Io=100%)
85typ (Io=90%)
85typ (Io=100%)
88typ (Io=100%)
INPUT
POWER FACTOR
ACIN 100V 20/40typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
INRUSH CURRENT[A] ACIN 115V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
ACIN 230V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
1.5max (ACIN 115V / 240V, 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
12 15 24 36
48
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
CURRENT[A]
WATTAGE[W]
ACIN 115V-264V 50
40
25
16.7
12.5
ACIN 85-115V Output derating is required at ACIN 115V or less (refer to instruction manual 3.2)
ACIN 115V-264V 600
600
600
601.2
600
*
8
LINE REGULATION[mV]
LOAD REGULATION[mV]
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
*
8
100max
0 to +50C 120max
-20 to 0C 160max
0 to +50C 150max
-20 to 0C 180max
0 to +50C 120max
-20 to +50C 180max
RIPPLE[mVp-p]
*1
*1
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
*
2
48max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
300typ (ACIN 115V, Io=100%)
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
32.40 to 39.60
36.00 to 37.44
43.20 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
12.00 to 12.48
Works over 105% of rating and recovers automatically
17.25 to 21.00 27.60 to 33.60
OVERVOLTAGE PROTECTION[V] 13.80 to 16.80
41.40 to 50.40
55.20 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
INPUT-FG
OUTPUT RC-FG
OUTPUT-RC
Optional (Option -W)
Optional (Required external power source. Option -R)
*
3
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
ISOLATION
*
*
*
3
3
5
OPERATING TEMP.,HUMID.AND ALTITUDE
-20 to +70C(Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
10
April17, 2018
PLA-14
PLA600F
SPECIFICATIONS
CASE SIZE/WEIGHT
COOLING METHOD
120X61X215mm [4.72X2.40X8.46 inches] (Excluding terminal block and screw) (WXHXD) / 2.0kg max
Forced cooling (internal fan)
OTHERS
*
*
9
6
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of *3 The RC terminal is added to option –R models. The RC terminal is
*9 The fan speed slows down at no load.
*10 Consult us about other classes.
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
isolated from input, output, and FG.
*4 As for DC input, consult us for advice.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be damaged.
Parallel operation is allowed for PLA600F models with the –W option only.
Sound noise may be heard from the power supply when used for pulse load.
*5 Output power derating is required. See 3.2 in Instruction Manual.
*6 See 3.3 in Instruction Manual for more details.
See 1.6 of Instruction Manual for more details.
*
*
*2 Drift is the change in DC output for an eight hour period after a half-hour *7 Consult us about safety agency approvals for the models with optional functions.
warm-up at 25C.
*8 Consult us about dynamic load and input response.
Features
-
-
-
-
Cost-effective
-
-
-
-
Screw hold type terminal block
Slow fan speed at no load
Longer life (see Instruction Manual)
Low profile (meets 2U height = 61 mm or 2.40 inches)
Wide operating temperature range (-20 to +70 see
instruction manual)
Many optional functions
Complies with SEMI F-47 (-U option, see Instruction
Manual for details)
Block diagram
BOOSTER
INDUCTOR
FUSE
250V 16A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
NOISE
CURRENT
SENSING
RECTIFIER
AC IN 85 - 264V
FILTER
INVERTER
CONTROL
FG
CURRENT
SENSING
RC (-R)
External source
THERMAL
PROTECTION
PARALLEL-OPERATION
CIRCUIT
CONTROL
INVERTER
CONTROL
Current balance (-W)
LV alarm (-W)
OVER VOLTAGE
PROTECTION
DETECTING
OUTPUT VOLTAGE
RECTIFIER
AND
DC OUT
FILTER
CONTROL
FAN
External view
The external size of –V option, –W option, –R option, and –T2 option is different from the standard model. See “5. Options and Others”
in Instruction Manual for more details.
26.6 1.5
[1.05]
16.6 1.5
[0.65]
15.8 1.5 (LED)
[0.62]
Output
terminal cover
12.1 1.5 (potentiometer)
4-M4
[0.48]
Mounting Hole
(Bottom sides)
M4
(+V,-V)
Name plate
21max
[0.83max]
LED
Output voltage
adjustable potentiometer
Output terminal (+)
Output terminal (-)
FG(
)
AC(N)
AC(L)
M3.5
(AC,FG)
15.5 1.5
[0.61]
35
150 0.5
[5.91]
[1.38]
215
3max
[8.46]
[0.12max]
¶ Tolerance : 1 [ 0.04]
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material
Case material Electric galvanizing steel board
Dimensions in mm, [ ]=inches
Mounting torque 1.5N-m max
Screw tightening torque M3.5 0.8N-m max
M4 1.6N-m max
Connect the input FG to safety earth ground.
: 2.0kg max
AIR FLOW
:
FR-4 / 1.6mm [0.06inches]
:
Electric galvanizing steel board
:
:
35
150 0.5
[5.91]
:
[1.38]
4-M4
Mounting Hole
¶
April17, 2018
PLA-15
相关型号:
©2020 ICPDF网 联系我们和版权申明