CTR [CRYDOM]

DIN Rail Mount;
CTR
型号: CTR
厂家: CRYDOM INC.,    CRYDOM INC.,
描述:

DIN Rail Mount

文件: 总6页 (文件大小:686K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DIN Rail Mount  
Datasheet  
CTR Series  
Ratings 25 A per phase @ 600 VAC  
DIN-RAIL or Panel Mount 90mm (width) package  
UL 508 Endurance Rating for Enhanced Reliability  
SCR output for heavy industrial loads  
Overvoltage Protection Built in (Internal TVS)  
LED input Status indicator  
AC or DC control  
Zero voltage or instantaneous turn-on output  
UL Recognized, CE, RoHS and EMC Compliant  
PRODUCT SELECTION  
Control Voltage  
4-32 VDC Control  
90-140 VAC Control  
180-280 VAC Control  
25 A  
CTRD6025  
CRTB6025  
CTRC6025  
AVAILABLE OPTIONS  
Control Voltage  
B: 90 to 140 VAC  
C: 180 to 280 VAC  
D: 4 to 32 VDC  
Output Rating  
25: 25 Amps/phase  
Series  
CTR  
D
60  
25 -10  
CTR: Standard 3 phase  
90 mm DIN rail mount  
SSR package  
Thermal Pad  
Line Voltage Rating  
60: 48 to 600 VAC  
Blank: Zero Voltage  
Turn-On  
Turn-On  
-10: Instantaneous  
Required for valid part number  
For options only and not required for valid part number  
Not all part number combinations are available.  
Contact Crydom Technical Support for information on  
the availability of a specific part number.  
*
OUTPUT SPECIFICATIONS (1)  
Description  
Operating Voltage (47-63Hz) [VRMS]  
Transient Overvoltage [Vpk]  
Maximum Load Current [Arms] (2)  
Minimum Load Current [Arms]  
CTRx6025  
48-600  
1100  
25  
0.1  
Maximum Off-State Leakage Current @ Rated Voltage [mArms]  
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (3)  
Maximum On-State Voltage Drop @ Rated Current [Vpk]  
Maximum Surge Current (50/60 Hz, 1 cycle) [Apk]  
Maximum I² t for Fusing (50/60Hz, 1/2 cycle ) [A² sec]  
UL/IEC 60947 Motor Control Rating @ 240V [HP/KW] (4)  
UL/IEC 60947 Motor Control Rating @ 380V [HP/KW] (4)  
UL/IEC 60947 Motor Control Rating @ 480V [HP/KW] (4)  
Minimum Power Factor (with Maximum Load)  
Min/Max stranded wire  
0.25  
500  
1.35  
286/300  
410/374  
1/0.74  
2/1.48  
3/2.22  
0.5  
16/8 AWG  
16/10 AWG  
Min/Max solid wire  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
Datasheet  
(1)  
INPUT SPECIFICATIONS  
Description  
CTRD6025  
4.0-32 VDC  
4.0 VDC  
1.0 VDC  
22 mA  
CTRB6025  
90-140 Vrms  
90 Vrms  
10 Vrms  
15 mA  
CTRC6025  
180-280 Vrms  
180 Vrms  
10 Vrms  
19 mA  
Control Voltage Range  
Minimum Turn-On Voltage  
Must Turn-Off Voltage  
Minimum Input Current (5)  
Maximum Input Current (5)  
Maximum Turn-On Time [msec] (6)  
Maximum Turn-Off Time [msec]  
28 mA  
19 mA  
20  
30  
24 mA  
20  
30  
1/2 Cycle  
1/2 Cycle  
24/16 AWG  
Min/Max stranded/solid wire  
24/16 AWG  
24/16 AWG  
GENERAL SPECIFICATIONS (1)  
Description  
Dielectric Strength, Input/Output/Base (50/60Hz)  
Minimum Insulation Resistance (@ 500 VDC)  
Parameters  
4000 Vrms  
109 Ohm  
Maximum Capacitance, Input/Output  
Ambient Operating Temperature Range (7)  
Ambient Storage Temperature Range  
Status Indicator Display  
8 pF  
-20 to 80°C  
-40 to 100 °C  
Green LED  
21.2 oz. (600g)  
Box Clamp Type  
5.0-6.0 in lib (0.6-0.7 Nm)  
0.8 inch (20mm)  
Weight (typical)  
Terminals  
Recommended Terminal Screw Torque Range:  
Min. Side bye Side Spacing  
MECHANICAL SPECIFICATIONS (1)  
Tolerances: 0.02 ꢀn ꢁ 0.5 ꢂꢂ  
All dꢀꢂensꢀons are ꢀn: ꢀnches [ꢂꢀllꢀꢂeters]  
3.54  
[90.0]  
4.86  
[123.4]  
3.26  
[82.8]  
3.59  
[91.2]  
3.82  
[97.0]  
3.47  
[88.1]  
0.18  
[4.5]  
3.26  
[82.8]  
GENERAL NOTES  
(1) All parameters at 25°C unless otherwise specified.  
(2) See Derating Curves.  
(3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1  
(4) At 40°C Ambient temperature.  
(5) Turn-on time for DC control Instantaneous turn-on versions is 0.05 msec.  
(6) Input circuitry incorporates active current limiter.  
(7) For 180-280 VAC Control. Maximum Ambient operating temperatures is 60°C.  
For additional information or specific questions, contact Crydom Technical Support.  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
Datasheet  
WIRING DIAGRAM  
LOAD  
A
L3  
AC  
+
-
A1  
A2  
Load can be wired in Position A or B  
B
LOAD  
T3  
L2  
AC  
AC  
LOAD  
A
Load can be wired in Position A or B  
B
LOAD  
AC  
AC  
T2  
L1  
LOAD  
A
Load can be wired in Position A or B  
B
T1  
LOAD  
AC  
THERMAL DERATE INFORMATION  
Derating curve: CTR Series  
25  
20  
CTRB6025  
CTRD6025  
15  
10  
5
CTRC6025  
0
30  
40  
50  
60  
70  
80  
Ambient Temperature (ºC)  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
Datasheet  
AGENCY APPROVALS  
Agency Approvals  
Designed in accordance with the requirements of IEC 62314  
E79183  
EMC Compatibility  
IEC 62314  
IEC 60068-2-6 35mm/10-55Hz  
IEC 60068-2-27 15G / 11ms  
IEC 61000-4-2 Level 3 Electrostatic Discharge  
IEC 61000-4-3 Level 3 Radiated Electromagnetic Noise  
IEC 61000-4-4 Level 3 Immunity to Electrically Fast Transients  
IEC 61000-4-5 Level 3 Immunity to Electrical Surges  
IEC 61000-4-6 Level 3 Conducted Electromagnetic Noise  
CISPR 11 Class A Conducted and Radiated Noise for Industrial Environments  
Pollution Degree 2  
Rev. 053116  
Overvoltage Category III  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
Datasheet  
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险  
HAZARD OF  
ELECTRIC  
SHOCK,  
EXPLOSION,  
OR ARC FLASH.  
RIESGO DE  
DESCARGA  
ELECTRICA O  
EXPLOSION.  
RISQUE DE  
GEFAHR EINES  
ELEKTRISCHE  
N SCHLAGES  
ODER EINER  
EXPLOSION.  
RISCHIO DI  
SCOSSA  
ELETTRICA O  
DELL’ESPLOSIONE.  
存在电击、  
爆炸或电弧  
闪烁危险  
DESCHARGE  
ELECTRIQUE  
OU EXPLOSION  
在操作此设  
备之前请先  
关闭电源。  
Eteindre  
toutes les  
sources  
d'énergie de  
cet appareil  
avant de  
travailler  
dessus de cet  
appareil  
Spenga tutta  
l'alimentazione  
che fornisce  
questa  
apparecchiatura  
prima di lavorare  
a questa  
Desconectar  
todos los  
suministros de  
energia a este  
equipo antes  
de trabajar  
Disconnect all  
power before  
installing or  
working with  
this equipment.  
Stellen Sie  
jeglichen  
Strom ab, der  
dieses Gerät  
versorgt, bevor  
Sie an dem  
若不遵守这些说明,  
可能会导致严重的  
人身伤害甚至死亡。  
con este equipo.  
Verify all  
connections  
and replace all  
covers before  
turning on  
Gerät Arbeiten  
durchführen  
apparecchiatura  
Verificar todas  
las conexiones  
y colocar todas  
las tapas antes  
de energizer  
Verificare tutti  
i collegamenti  
e sostituire  
tutte le coperture  
prima  
Vor dem  
Drehen auf  
Energie alle  
Anschlüsse  
überprüfen  
und alle  
Vérifier tous  
connections, et  
remettre tous  
couverts en  
olace avant de  
mettre sous  
power.  
el equipo.  
Failure to follow  
these  
instructions will  
result in death  
or serious injury.  
dell’accensione  
El  
Abdeckungen  
ersetzen.  
L'omissione di  
queste istruzioni  
provocherà la  
morte o  
incumplimiento  
de estas  
instrucciones  
puede provocar  
la muerte o  
lesiones serias.  
De non-suivi de  
ces instructions  
provoquera la  
mort ou des  
lésions sérieuses  
sérieuses.  
Unterlassung  
dieser  
Anweisungen  
können zum  
Tode oder zu  
schweren  
lesioni serie  
Verletzungen  
führen.  
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告  
RISQUE DE DOMMAGE MATERIEL ET DE  
SURCHAUFFE DU BOITIER  
GEFAHR VON MATERIALSCHÄDEN UND  
GEHÄUSEERHITZUNG  
RISK OF MATERIAL DAMAGE AND HOT  
ENCLOSURE  
Les panneaux latéraux du produit peuvent être  
chauds. Laisser le produit refroidir avant de le  
toucher.  
Respecter les consignes de montage, et  
notamment les couples de serrage.  
Ne pas laisser pénétrer de liquide ni de corps  
étrangers à l'intérieur du produit.  
Die Seitenwände können heiß sein. Lassen Sie  
das Produkt abkühlen, bevor Sie es berühren.  
Beachten Sie die Montageanweisungen,  
Führen Sie keine Flüssigkeiten oder  
The product's side panels may be hot, allow  
the product to cool before touching.  
Follow proper mounting instructions including  
torque values.  
Do not allow liquids or foreign objects to enter  
this product.  
Fremdkörper in das Produkt ein.  
Le non-respect de cette directive peut entraîner,  
des lésions corporelles graves ou des  
dommages matériels.  
Die Nichtbeachtung dieser Anweisung kann  
Körperverletzung oder Materialschäden  
zur Folge haben.  
Failure to follow these instructions can result in  
serious injury, or equipment damage.  
RIESGO DE DAÑOS MATERIALES Y DE  
SOBRECALENTAMIENTO DE LA UNIDAD  
材料损坏和高温外壳的危险性  
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO  
CALDO  
 产品的一侧面板可能很热,在其冷却前请  
 不要触碰。  
 遵照正确的安装说明,包括扭矩值。  
 请勿让液体及其他异物进入本产品。  
Los paneles laterales del producto pueden  
estar calientes. Esperar que el producto se  
enfríe antes de tocarlo.  
Respetar las instrucciones de montaje, y en  
particular los pares de apretado.  
I pannelli laterali dell'apparecchio possono  
scottare; lasciar quindi raffreddare il prodotto  
prima di toccarlo.  
Seguire le istruzioni di montaggio corrette.  
Non far entrare liquidi o oggetti estranei in questo  
apparecchio.  
No dejar que penetren líquidos o cuerpos  
extraños en el producto.  
La mancata osservanza di questa precauzione può  
causare gravi rischi per l'incolumità personale o  
danni alle apparecchiature.  
如不能正确执行这些操作说明,  
极有可能造成严重人体伤害或者设备的损坏。  
Si no se respetan estas precauciones pueden  
producirse graves lesiones, daños materiales.  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
Datasheet  
ANNEX - ENVIROMENTAL INFORMATION  
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China  
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.  
Part  
Name  
Toxic or hazardous Substance and Elements  
Lead  
(Pb)  
Mercury  
(Hg)  
Cadmium  
(Cd)  
Hexavalent  
Chromium  
(Cr (VI))  
Polybrominated  
biphenyls  
(PBB)  
Polybrominated  
diphenyl ethers  
(PBDE)  
Semiconductor die  
Solder  
附件 - 环保信息  
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,  
电子信息产品污染控制标识要求。  
部件  
名称  
有毒有害物质或元素  
(Pb)  
(Hg)  
(Cd)  
六价铬  
(Cr (VI))  
多溴联苯  
(PBB)  
多溴二苯醚  
(PBDE)  
半导体芯片  
焊接点  
50  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY