D4825FSH-10 [CRYDOM]

Panel Mount;
D4825FSH-10
型号: D4825FSH-10
厂家: CRYDOM INC.,    CRYDOM INC.,
描述:

Panel Mount

文件: 总7页 (文件大小:933K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Panel Mount  
Datasheet  
Series 1 480 VAC  
Ratings from 25 A to 90 A @ 48-530 VAC  
SCR output for heavy industrial loads  
Zero voltage or instantaneous turn-on outputs  
AC or DC control  
Direct bond copper substrate  
EMC compliant to Level 3  
UL/CSA/VDE Approved, CE Compliant to EN60950-1 Direct power lead frame  
Improved SEMS screw and washer  
Epoxy free design  
Redesigned housing with anti-rotation barriers  
For Generation 3 datasheet click here  
PRODUCT SELECTION  
Control Voltage  
4-32 VDC  
25 A  
D4825  
A4825  
50 A  
D4850  
A4850  
75 A  
D4875  
A4875  
90 A  
D4890  
A4890  
90-280 VAC  
AVAILABLE OPTIONS  
Termination  
Blank: Screw  
Control Voltage  
A: 90-280 VAC  
D: 4-32 VDC  
Thermal Pad  
Blank: Not Included  
H: Included  
F: Quick Connect (1)  
(Up to 50 Amps)  
K: Hex standoffs (2)  
-10  
A
K
S
H
48  
25  
Switching Type  
Operating  
Voltage  
Rated Load Current  
25: 25 Amps  
Snubber  
Blank: Zero Voltage Turn-On  
-10: Instantaneous Turn-On (3)  
Blank: Not Included  
S: Included  
48: 48-530 VAC 50: 50 Amps  
75: 75 Amps  
90: 90 Amps  
Required for valid part number  
For options only and not required for valid part number  
* Not all part number combinations are available.  
Contact Crydom Technical support for information on  
the availability of a specific part number.  
OUTPUT SPECIFICATIONS (4)  
Description  
Operating Voltage (47-440Hz) [Vrms] (5)  
Transient Overvoltage [Vpk]  
25 A  
48-530  
800  
50 A  
48-530  
800  
75 A  
48-530  
800  
90 A  
48-530  
800  
Maximum Off-State Leakage Current @ Rated Voltage [mArms] (6)  
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]  
Maximum Load Current [Arms] (2)(7)  
1
500  
25  
1
500  
50  
1
500  
75  
1
500  
90  
Minimum Load Current [mArms]  
150  
150  
150  
150  
Maximum 1 Cycle Surge Current (50/60Hz) [Apk]  
Maximum On-State Voltage Drop @ Rated Current [Vrms]  
Thermal Resistance Junction to Case (Rjc) [°C/W]  
Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]  
Minimum Power Factor (at Maximum Load)  
239/250  
1.15  
0.8  
285/259  
0.5  
597/625  
1.15  
0.45  
1770/1621  
0.5  
954/1000  
1.15  
0.3  
4555/4150  
0.5  
1145/1200  
1.15  
0.27  
6560/5976  
0.5  
INPUT SPECIFICATIONS (4)  
Description  
Control Voltage Range  
Maximum Reverse Voltage  
Minimum Turn-On Voltage  
Must Turn-Off Voltage  
Minimum Input Current  
Maximum Input Current  
Nominal Input Impedance  
Maximum Turn-On Time [msec]  
Maximum Turn-Off Time [msec]  
D48xx  
4-32 VDC  
-32 VDC  
4.0 VDC (8)  
1.0 VDC  
7.0 mA  
A48xx  
90-280 Vrms (60Hz)  
-
90 Vrms  
10 Vrms  
5.0 mA  
12 mA  
Current Regulated  
10 mA  
Current Regulated  
20  
1/2 Cycle (9)  
1/2 Cycle  
30  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
Panel Mount  
Datasheet  
(4)  
GENERAL SPECIFICATIONS  
Description  
Dielectric Strength, Input/Output/Base (50/60Hz)  
Minimum Insulation Resistance (@ 500 VDC)  
Parameters  
4000 Vrms  
109 Ohm  
Maximum Capacitance, Input/Output  
Ambient Operating Temperature Range  
Ambient Storage Temperature Range  
Weight (typical)  
8 pF  
-40 to 80 °C  
-40 to 125 °C  
2.6 oz (74.9 g)  
Housing Material  
94 V-0  
Baseplate Material  
Aluminum  
Input Terminal Screw Torque Range (in-lb/Nm)  
Load Terminal Screw Torque Range (in-lb/Nm)  
SSR Mounting Screw Torque Range (in-lb/Nm)  
13-15 /1.5-1.7  
18-20 / 2.0-2.2  
18-20 / 2.0-2.2  
Input/Load Terminal Screw Torque Range (in-lb/Nm) (2)  
Input/Output Terminal Screw Thread Size  
Humidity per IEC60068-2-78  
MTBF (Mean Time Between Failures) at 40°C ambient temperature (10)  
w/”K” option 8-10 / 0.9-1.13  
#6-32 UNC / #8-32 UNC  
93% non-condensing  
11,641,553 hours (1,328 years)  
7,210,376 hours (823 years)  
MTBF (Mean Time Between Failures) at 60°C ambient temperature (10)  
WIRING DIAGRAM  
AC  
Input Current vs Input Voltage  
Standard Regulated DC Input  
Recommended Wire Sizes  
V
Wire Size  
(Solid / Stranded)  
Wire Pull-Out  
Strength (lb)[N]  
25  
20  
Terminals  
Input  
(11)  
Load  
2 (  
24 AWG (0.2 mm2) / 0.2 [minimum]  
2 x 12 AWG (3.3 mm2) / 3.3 [maximum]  
20 AWG (0.5 mm2) / 0.518 [minimum]  
2 x 10 AWG (5.3 mm2) / 5.3  
10 [44.5]  
90 [400]  
30 [133]  
110 [490]  
90 [400]  
1 (  
)
)
15  
10  
5
Output  
2
1
OUTPUT  
S O L I D S TAT E R E L AY  
2 x 8 AWG (8.4 mm2) / 8.4 [maximum]  
0
0
5
10  
15  
20  
25  
30  
4
INPUT  
3
DC Input Voltage  
4 (– / )  
3 (+ / )  
EQUIVALENT CIRCUIT BLOCK DIAGRAMS  
Diagram: Series 1 DC  
Diagram: Series 1 AC  
4
3
1
2
4
3
1
2
-
DC  
AC  
AC  
AC  
AC  
AC  
AC  
Current  
Limiter  
AC/DC  
Converter  
Trigger  
Circuit  
Trigger  
Circuit  
(12)  
(12)  
+DC  
Current  
Limiter  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
Panel Mount  
Datasheet  
MECHANICAL SPECIFICATIONS (4)  
Tolerances: 0.02 ꢀn ꢁ 0.5 ꢂꢂ  
All dꢀꢂensꢀons are ꢀn: ꢀnches [ꢂꢀllꢀꢂeters]  
(2)  
Screw Termination  
Hex Standoff Termination (“K” Option)  
1.1  
1.1  
Mounting  
0.89  
[22.6]  
[27.9]  
1.04  
[26.4]  
[27.9]  
Hole/Slot  
0.19 [4.9]  
DIA.  
Mounting  
0.49  
[12.4]  
0.49  
[12.4]  
Hole/Slot  
0.19 [4.9]  
DIA.  
2
1
OUTPUT  
2
1
OUTPUT  
S O L I D S TAT E R E L AY  
2.25  
[57.3]  
1.70  
[43.2]  
1.88  
[47.6]  
S O L I D S TAT E R E L AY  
2.25  
[57.3]  
1.88  
[47.6]  
1.7  
[43.2]  
4
INPUT  
3
4
INPUT  
3
0.93  
[23.6]  
1.0  
1.0  
[25.4]  
[25.4]  
(4 places)  
1.75  
[44.5]  
1.75  
[44.5]  
1.0  
[25.4]  
(2 places)  
Quick Connect Termination (“F” Option) - Up to 25 Amp (1)  
Quick Connect Termination (“F” Option) - Up to 50 Amp (1)  
Faston Terminal(13)  
0.25 x 0.032  
1.58  
1.58  
[40.2]  
0.63  
1.31  
[33.4]  
1.31  
[33.4]  
Faston Terminal(13)  
0.25 x 0.032  
[40.2]  
Mounting  
Hole/Slot  
0.19 [4.9]  
DIA.  
Mounting  
Hole/Slot  
0.19 [4.9]  
DIA.  
(4 places)  
0.49  
[12.4]  
(2 places)  
[16.0]  
0.45  
[11.4]  
(2 places)  
2
1
OUTPUT  
2
1
OUTPUT  
S O L I D S TAT E R E L AY  
S O L I D S TAT E R E L AY  
2.25  
[57.3]  
1.88  
[47.6]  
1.7  
[43.2]  
2.25  
[57.3]  
1.88  
[47.6]  
1.7  
[43.2]  
4
INPUT  
3
4
INPUT  
3
0.49  
1.40  
Faston Terminal(13)  
0.187 x 0.020  
[12.4]  
[35.6]  
Faston Terminal(13)  
0.187 x 0.020  
1.40  
[35.6]  
1.75  
1.25  
[31.8]  
1.75  
[44.5]  
1.25  
[31.8]  
(2 places)  
(2 places)  
[44.5]  
GENERAL NOTES  
(1) Single pair (up to 25 A) Double pair* (50 A model only). *Caution: User must connect to both pairs.  
(2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps.  
For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support.  
(3) Instantaneous turn-on not recomended for capacitive loads. Use zero turn-on only.  
(4) All parameters at 25°C unless otherwise specified.  
(5) For “S” option, operating voltage frequency is 47-63Hz.  
(6) For parts with option “S” maximum leakage current is 10mA.  
(7) Heat sinking required, see derating curves.  
(8) Increase minimum voltage by 1V for operations from -20 to -40°C.  
(9) Turn-on time for Instantaneous turn-on versions is 0.02 msec (DC Control Models).  
(10) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).  
(11) Load can be wired to either SSR output terminal 1 or 2.  
(12) Elective Internal Snubber, “S” option.  
(13) Mechanical dimensions vary from G3 models.  
For additional information or specific questions, contact Crydom Technical Support.  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
Panel Mount  
Datasheet  
SURGE CURRENT INFORMATION  
25 A  
50 A  
250  
600  
500  
400  
300  
200  
100  
0
200  
150  
100  
50  
0
0.01  
0.1  
1
10  
0.01  
0.1  
1
10  
Surge Duration (Secs)  
Surge Duration (Secs)  
75 A  
90 A  
900  
1200  
1050  
900  
750  
600  
450  
300  
150  
800  
700  
600  
500  
400  
300  
200  
100  
0
0
0.01  
0.01  
0.1  
1
10  
0.1  
1
10  
Surge Duration (Secs)  
Surge Duration (Secs)  
Non repetitive peak surge current at Tj initial 40ºC.  
THERMAL DERATE INFORMATION  
25 A  
50 A  
1.5ºC/W  
2ºC/W  
0.7ºC/W  
1ºC/W  
3ºC/W  
1.5ºC/W  
2ºC/W  
25  
20  
15  
10  
5
50  
40  
30  
20  
10  
0
0
20  
30  
40  
50  
60  
70  
80  
20  
30  
40  
50  
60  
70  
80  
Ambient Temperature (ºC)  
Ambient Temperature (ºC)  
75 A  
90 A  
0.5ºC/W  
0.7ºC/W  
0.5ºC/W  
0.7ºC/W  
1ºC/W  
1.5ºC/W  
1ºC/W  
1.5ºC/W  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
75  
60  
45  
30  
15  
0
20  
30  
40  
50  
60  
70  
80  
20  
30  
40  
50  
60  
70  
80  
Ambient Temperature (ºC)  
Ambient Temperature (ºC)  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
Panel Mount  
Datasheet  
AGENCY APPROVALS  
EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:  
Designed in accordance with the requirements of IEC 62314  
IEC 61000-4-2 : Electrostatic Discharge – Level 3  
IEC 61000-4-4 : Electrically Fast Transients – Level 3  
IEC 61000-4-5 : Electrical Surges – Level 3  
IEC 60068-2-6 : Vibration 0.33mm and 0.75 mm Amplitude over 10-55 Hz  
IEC 60068-2-27 : Shock Resistance 15g/11ms  
E116949  
LR81689  
10143 UG  
ACCESORIES  
Recommended Accessories  
New Accessories!  
Protective Cover & Hardware Kits  
Cover  
Hardware  
Kit  
Heat Sink  
Part No.  
Thermal Resistance Lug Terminal Thermal Pad  
[ºC/W]  
Protective Cover  
Part number: KS101  
5.0  
HS501DR  
KS101  
HK1  
HK4  
TRM1  
TRM6  
HSP-1  
HSP-2  
Clear plastic cover compatible with all new  
S1 designs. Safety covers provide added  
protection from electric shock when  
installing or checking equipment.  
3.0  
2.5  
2.0  
2.0  
1.7  
1.5  
1.2  
1.0  
1.0  
0.7  
0.7  
0.5  
0.36  
0.25  
HS301 / HS301DR  
HS251  
HS202 / HS202DR  
HS201 / HS201DR  
HS172  
Hardware Kit  
Part number: HK4  
HS151 / HS151DR  
HS122 / HS122DR  
HS103 / HS103DR  
HS101  
Bag with 2 square brass accessories and 2  
screw 8-32 x 5/8 for output. Used to mount  
TMR1 lug terminals.  
HS073  
HS072  
HS053  
HS033  
HS023  
Rev. 041116  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
Panel Mount  
Datasheet  
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险  
HAZARD OF  
ELECTRIC  
SHOCK,  
EXPLOSION,  
OR ARC FLASH.  
RIESGO DE  
DESCARGA  
ELECTRICA O  
EXPLOSION.  
RISQUE DE  
GEFAHR EINES  
ELEKTRISCHE  
N SCHLAGES  
ODER EINER  
EXPLOSION.  
RISCHIO DI  
SCOSSA  
ELETTRICA O  
DELL’ESPLOSIONE.  
存在电击、  
爆炸或电弧  
闪烁危险  
DESCHARGE  
ELECTRIQUE  
OU EXPLOSION  
在操作此设  
备之前请先  
关闭电源。  
Eteindre  
toutes les  
sources  
d'énergie de  
cet appareil  
avant de  
travailler  
dessus de cet  
appareil  
Spenga tutta  
l'alimentazione  
che fornisce  
questa  
apparecchiatura  
prima di lavorare  
a questa  
Desconectar  
todos los  
suministros de  
energia a este  
equipo antes  
de trabajar  
Disconnect all  
power before  
installing or  
working with  
this equipment.  
Stellen Sie  
jeglichen  
Strom ab, der  
dieses Gerät  
versorgt, bevor  
Sie an dem  
若不遵守这些说明,  
可能会导致严重的  
人身伤害甚至死亡。  
con este equipo.  
Verify all  
connections  
and replace all  
covers before  
turning on  
Gerät Arbeiten  
durchführen  
apparecchiatura  
Verificar todas  
las conexiones  
y colocar todas  
las tapas antes  
de energizer  
Verificare tutti  
i collegamenti  
e sostituire  
tutte le coperture  
prima  
Vor dem  
Drehen auf  
Energie alle  
Anschlüsse  
überprüfen  
und alle  
Vérifier tous  
connections, et  
remettre tous  
couverts en  
olace avant de  
mettre sous  
power.  
el equipo.  
Failure to follow  
these  
instructions will  
result in death  
or serious injury.  
dell’accensione  
El  
Abdeckungen  
ersetzen.  
L'omissione di  
queste istruzioni  
provocherà la  
morte o  
incumplimiento  
de estas  
instrucciones  
puede provocar  
la muerte o  
lesiones serias.  
De non-suivi de  
ces instructions  
provoquera la  
mort ou des  
lésions sérieuses  
sérieuses.  
Unterlassung  
dieser  
Anweisungen  
können zum  
Tode oder zu  
schweren  
lesioni serie  
Verletzungen  
führen.  
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告  
RISQUE DE DOMMAGE MATERIEL ET DE  
SURCHAUFFE DU BOITIER  
GEFAHR VON MATERIALSCHÄDEN UND  
GEHÄUSEERHITZUNG  
RISK OF MATERIAL DAMAGE AND HOT  
ENCLOSURE  
Les panneaux latéraux du produit peuvent être  
chauds. Laisser le produit refroidir avant de le  
toucher.  
Respecter les consignes de montage, et  
notamment les couples de serrage.  
Ne pas laisser pénétrer de liquide ni de corps  
étrangers à l'intérieur du produit.  
Die Seitenwände können heiß sein. Lassen Sie  
das Produkt abkühlen, bevor Sie es berühren.  
Beachten Sie die Montageanweisungen,  
Führen Sie keine Flüssigkeiten oder  
The product's side panels may be hot, allow  
the product to cool before touching.  
Follow proper mounting instructions including  
torque values.  
Do not allow liquids or foreign objects to enter  
this product.  
Fremdkörper in das Produkt ein.  
Le non-respect de cette directive peut entraîner,  
des lésions corporelles graves ou des  
dommages matériels.  
Die Nichtbeachtung dieser Anweisung kann  
Körperverletzung oder Materialschäden  
zur Folge haben.  
Failure to follow these instructions can result in  
serious injury, or equipment damage.  
RIESGO DE DAÑOS MATERIALES Y DE  
SOBRECALENTAMIENTO DE LA UNIDAD  
材料损坏和高温外壳的危险性  
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO  
CALDO  
 产品的一侧面板可能很热,在其冷却前请  
 不要触碰。  
 遵照正确的安装说明,包括扭矩值。  
 请勿让液体及其他异物进入本产品。  
Los paneles laterales del producto pueden  
estar calientes. Esperar que el producto se  
enfríe antes de tocarlo.  
Respetar las instrucciones de montaje, y en  
particular los pares de apretado.  
I pannelli laterali dell'apparecchio possono  
scottare; lasciar quindi raffreddare il prodotto  
prima di toccarlo.  
Seguire le istruzioni di montaggio corrette.  
Non far entrare liquidi o oggetti estranei in questo  
apparecchio.  
No dejar que penetren líquidos o cuerpos  
extraños en el producto.  
La mancata osservanza di questa precauzione può  
causare gravi rischi per l'incolumità personale o  
danni alle apparecchiature.  
如不能正确执行这些操作说明,  
极有可能造成严重人体伤害或者设备的损坏。  
Si no se respetan estas precauciones pueden  
producirse graves lesiones, daños materiales.  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  
Panel Mount  
Datasheet  
ANNEX - ENVIROMENTAL INFORMATION  
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China  
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.  
Part  
Name  
Toxic or hazardous Substance and Elements  
Lead  
(Pb)  
Mercury  
(Hg)  
Cadmium  
(Cd)  
Hexavalent  
Chromium  
(Cr (VI))  
Polybrominated  
biphenyls  
(PBB)  
Polybrominated  
diphenyl ethers  
(PBDE)  
Semiconductor die  
Solder  
附件 - 环保信息  
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,  
电子信息产品污染控制标识要求。  
部件  
名称  
有毒有害物质或元素  
(Pb)  
(Hg)  
(Cd)  
六价铬  
(Cr (VI))  
多溴联苯  
(PBB)  
多溴二苯醚  
(PBDE)  
半导体芯片  
焊接点  
50  
Do not forget to visit us at: www.crydom.com  
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.  

相关型号:

D4825KHT-10

Panel Mount
CRYDOM

D4825KSH-10

Series 1 480 VAC
CRYDOM

D4825T

Panel Mount
CRYDOM

D4825_13

panel mount
CRYDOM

D4840-10

Series 1 480 VAC
CRYDOM

D48481-000

PTC Resettable Fuse, Surface Mount, ROHS COMPLIANT
LITTELFUSE

D4850

panel mount
CRYDOM