NQB-100NWA-DANL-000-ESA [CUI]

FULLY REGULATED ADVANCED BUS CONVERTERS; 全面监管的先进的总线转换器
NQB-100NWA-DANL-000-ESA
型号: NQB-100NWA-DANL-000-ESA
厂家: CUI INC    CUI INC
描述:

FULLY REGULATED ADVANCED BUS CONVERTERS
全面监管的先进的总线转换器

转换器
文件: 总30页 (文件大小:1740K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
date 02/20/2013  
page 1 of 30  
SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
FEATURES  
• industry standard quarter-brick  
GENERAL CHARACTERISTICS  
• industry standard footprint  
• isolated topology  
57.9 x 36.8 x 11.3 mm  
(2.28 x 1.45 x 0.445 in)  
• high power density  
• industry-leading power density for  
telecom and datacom 127~141W / sq. in  
• high efficiency, typ. 96.4% at half load,  
12 Vout  
• fast transient response  
• high conversion efficiency  
• wide range of input and output  
characteristics available  
• fully regulated advanced bus converter  
from 36~75Vin  
• 2,250 Vdc input to output isolation  
• fast feed forward regulation to manage  
line transients  
• optional baseplate for high temperature  
applications  
• droop load sharing with 10% current  
share accuracy  
• 2.9 million hours MTBF  
• ISO 9001/14001 certified supplier  
input voltage  
output voltage  
output current  
output wattage  
MODEL  
max  
max  
(Vdc)  
(Vdc)  
12  
(A)  
(W)  
NQB-420NWA-AN  
NQB-468NMA-AN  
NQB-415NWB-AN  
NQB-462NMB-AN  
36~75  
40~60  
36~75  
40~60  
35  
39  
35  
39  
420  
468  
415  
462  
12  
12.45  
12.45  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 2 of 30  
PART NUMBER KEY  
NQB- XXX N X X - X X X X - XXX -ES X  
Base Number  
Engineering Phase:  
A~Z  
Design Output Power:  
1~999  
Engineering Sample:  
ES  
No Digital Interface  
Firmware Configuration:  
000~ZZZ  
Input Voltage Range:  
W = wide (36~75 V)  
M = medium (40~60 V)  
Heatsink Option:  
"blank" = open frame  
H = heatsink flat  
L = heatsink lateral fins  
T = heatsink transverse fins  
G = heatsink with GND pin  
Nominal Output Voltage:  
A = 12.0 V  
B = 12.45 V  
C = 9.6 V  
D = 9.0 V  
E = 5.0 V  
Enable Logic Sense:  
N = negative logic  
P = positive logic  
Load Sharing Function:  
D = Vout droop  
Pin Description:  
A = 5.33 mm (0.210 in.)  
B = 4.57 mm (0.180 in.)  
C = 3.69 mm (0.145 in.)  
D = 2.79 mm (0.110 in.)  
S = SMT  
Packaging:  
Example part number: NQB-420NWA-AN-001  
20 converters(through hole pin)/tray, PE foam dissipative  
20 converters(surface mount pin)/tray, Antistatic PPE  
420 W output power, no digital pins  
wide input voltage range, 12.0 V output  
5.33 mm pins, negative enable logic  
firmware revision 001  
CONTENTS  
Part Number Key........................................................2 EMC Specification.........................................19  
General Information...................................................3 Operating Information...................................19  
Safety Specification....................................................3 Thermal Consideration..................................21  
Absolute Maximum Ratings..........................................4 Connections............................................22  
Mechanical Information.................................23  
Electrical Specification:  
Soldering Information...................................26  
Delivery Package Information.........................27  
Product Qualification Specification...................29  
12V,35A, 420W,36~75Vin; NQB-420NWA-AN....................5  
12V, 39A, 468W, 40~60Vin; NQB-468NMA-AN..................9  
12.45 V, 35 A, 415 W, 36~75 Vin; NQB-415NWB-AN............13  
12.45 V, 39 A, 462 W, 40~60 Vin; NQB-420NMB-AN............16  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 3 of 30  
General Information  
Reliability  
the requirements of all applicable safety standards and  
regulations for the final product.  
The failure rate (λ) and mean time between failures  
(MTBF= 1/ λ) is calculated at max output power and  
an operating ambient temperature (TA) of +40°C. CUI  
Power Modules uses Telcordia SR-332 Issue 2 Method 1 to  
calculate the mean steady-state failure rate and standard  
deviation (σ).  
Component power supplies for general use should comply  
with the requirements in IEC/EN/UL 60950 1 Safety  
of Information Technology Equipment. Product related  
standards, e.g. IEEE 802.3af Power over Ethernet, and  
ETS 300132 2 Power interface at the input to telecom  
equipment, operated by direct current (dc) are based on  
IEC/EN/UL 60950 1 with regards to safety.  
Telcordia SR-332 Issue 2 also provides techniques to  
estimate the upper confidence levels of failure rates based  
on the mean and standard deviation.  
CUI Power Modules DC/DC converters and DC/DC  
regulators are UL 60950 1 recognized and certified in  
accordance with EN 60950 1. The flammability rating for  
all construction parts of the products meet requirements  
for V 0 class material according to IEC 60695 11 10, Fire  
hazard testing, test flames – 50 W horizontal and vertical  
flame test methods.  
Mean steady-state failure rate, λ Std. deviation, σ  
421 n Failures/h  
60.9 nFailures/h  
MTBF (mean value) for the NQB series = 2.9 Mh.  
MTBF at 90% confidence level = 2.4 Mh  
Compatibility with RoHS requirements  
Isolated DC/DC converters  
The products are compatible with the relevant clauses  
and requirements of the RoHS directive 2011/65/EU and  
have a maximum concentration value of 0.1% by weight  
in homogeneous materials for lead, mercury, hexavalent  
chromium, PBB and PBDE and of 0.01% by weight in  
homogeneous materials for cadmium.  
Galvanic isolation between input and output is verified  
in an electric strength test and the isolation voltage  
(Viso) meets the voltage strength requirement for basic  
insulation according to IEC/EN/UL 60950-1.  
It is recommended to use a slow blow fuse at the input  
of each DC/DC converter. If an input filter is used in the  
circuit the fuse should be placed in front of the input filter.  
In the rare event of a component problem that imposes a  
short circuit on the input source, this fuse will provide the  
following functions:  
Exemptions in the RoHS directive utilized in CUI  
Power Modules products are found in the Statement of  
Compliance document.  
Safety Specification  
Reliability  
Isolate the fault from the input power source so as  
not to affect the operation of other parts of  
the system  
CUI Power Modules DC/DC converters and DC/DC  
regulators are designed in accordance with the safety  
standards IEC 60950 1, EN 60950 1 and UL 60950 1  
Safety of Information Technology Equipment.  
Protect the distribution wiring from excessive  
current and power loss thus preventing hazardous  
overheating  
The DC/DC converter output is considered as safety extra  
low voltage (SELV) if one of the following conditions is  
met:  
IEC/EN/UL 60950 1 contains requirements to prevent  
injury or damage due to the following hazards:  
Electrical shock  
Energy hazards  
Fire  
Mechanical and heat hazards  
Radiation hazards  
Chemical hazards  
The input source has double or reinforced  
insulation from the AC mains according to IEC/EN/  
UL 60950-1  
The input source has basic or supplementary  
insulation from the AC mains and the input  
of the DC/DC converter is maximum 60  
Vdc and connected to protective earth according to  
IEC/EN/UL 60950-1  
On-board DC/DC converters and DC/DC regulators are  
defined as component power supplies. As components  
they cannot fully comply with the provisions of any  
safety requirements without “conditions of acceptability.  
Clearance between conductors and between conductive  
parts of the component power supply and conductors on  
the board in the final product must meet the applicable  
safety requirements. Certain conditions of acceptability  
apply for component power supplies with limited stand-off  
(see Mechanical Information for further information). It is  
the responsibility of the installer to ensure that the final  
product housing these components complies with  
The input source has basic or supplementary  
insulation from the AC mains and the DC/DC  
converter output is connected to protective earth  
according to IEC/EN/UL 60950-1  
Non - isolated DC/DC regulators  
The DC/DC regulator output is SELV if the input source  
meets the requirements for SELV circuits according to IEC/  
EN/UL 60950-1.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 4 of 30  
Absolute Maximum Ratings  
parameter  
conditions/description  
min  
-40  
-55  
typ  
max  
+125  
+125  
units  
°C  
operating temperature (TP1)  
storage temperature (TS)  
see thermal consideration section  
°C  
+80  
+65*  
input voltage (VI)  
-0.5  
V
Vdc  
V
isolation voltage (Viso)  
input voltage transient (Vtr)  
input to output test voltage, see note 1  
2250  
according to ETSI EN 300 132-2 and Telcordia GR-  
1089-CORE  
+100  
+80*  
remote control pin voltage (VRC) see operating information section  
-0.3  
18  
V
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with one  
parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified  
manner.  
Note  
1: Isolation voltage (input/output to base-plate) max 750 Vdc.  
* Applies for the narrow input version VI= 40-60 V  
Fundamental Circuit Diagram  
+IN  
+OUT  
-OUT  
-IN  
Auxillary  
Supply  
Driver  
Control  
RC  
RC isolation  
Functional Description  
TP1, TP3 = -40 to +90ºC, VI = 36 to 75 V.  
Typical values given at: TP1, TP3 = +25°C, VI= 53 V, max IO , unless otherwise specified under Conditions  
Configuration File: 190 10-CDA 102 0314/001  
parameter  
conditions/description  
min  
typ  
max  
units  
fault protection  
characteristics  
fault limit  
33  
V
%
V
input under voltage lockout  
(UVLO)  
setpoint accuracy  
hysteresis  
delay  
-2  
2
2
300  
μs  
output voltage - under voltage  
protection  
fault limit  
fault response time  
0
200  
V
μs  
output voltage - over voltage  
protection  
fault limit  
fault response time  
15.6  
200  
V
μs  
setpoint accuracy (IO)  
fault limit  
fault response time  
-6  
6
%
A
μs  
over current protection (OCP)  
41  
200  
fault limit  
hysteresis  
fault response time  
125  
10  
300  
ºC  
ºC  
μs  
over temperature protection  
(OTP)  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 5 of 30  
Electrical Specification  
12.0 V, 35 A, 420 W  
TP1, TP3 = -40 to +90ºC, VI = 36 to 75 V.  
Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions.  
Additional Cout = 3.5 mF, Configuration File: 19010-CDA 102 0314/001  
parameter  
conditions/description  
min  
36  
typ  
max  
75  
units  
V
input voltage range (VI)  
turn-off input voltage (VIoff  
)
decreasing input voltage  
increasing input voltage  
32  
33  
35  
18  
34  
V
turn-on input voltage (VIon)  
internal input capacitance (CI)  
output power (PO)  
34  
36  
V
μF  
W
0
420  
50% of max IO  
max IO  
50% of max IO, VI = 48 V  
max IO, VI = 48 V  
96.2  
95.5  
96.4  
95.5  
%
%
%
%
efficiency (η)  
power dissipation (Pd)  
input idling power (Pli)  
input standby power (PRC)  
switching frequency (fs)  
max IO  
19.8  
3.3  
29.5  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0-100% of max IO  
0.4  
W
140  
kHz  
output voltage setting and ac-  
curacy (VOi)  
TP1 = +25°C, VI = 53 V, IO = 35 A  
0-100% of max IO  
11.88  
11.76  
12.0  
12.12  
12.24  
V
V
output voltage tolerance band  
(VO)  
line regulation (VO)  
load regulation (VO)  
max IO  
21  
6
55  
40  
mV  
mV  
VI = 53 V, 0-100% of max IO  
load transient voltage deviation VI = 53 V, load step 25-75-25% of max IO, di/dt =  
±0.4  
150  
8
V
(Vtr)  
1 A/μs  
load transient recovery time  
(ttr)  
VI = 53 V, load step 25-75-25% of max IO, di/dt =  
1 A/μs  
µs  
ramp-up time (tr) - (from  
10−90% of VOi)  
10-100% of max IO, TP1, TP3 = 25ºC, VI = 53 V  
10-100% of max IO, TP1, TP3 = 25ºC, VI = 53 V  
ms  
ms  
start-up time (ts) - (from VI  
connection to 90% of VOi)  
24  
VI shut-down fall time (tf) -  
(from VI off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
3.6  
7
ms  
s
RC start-up time (tRC)  
max IO  
12  
ms  
RC shut-down fall time (tRC) -  
(from RC off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
5.1  
7
ms  
s
output current (IO)  
0
35  
44  
A
A
A
current limit threshold (Ilim)  
short circuit current (Isc)  
VO = 10.8 V, TP1, TP3 < max TP1, TP3  
TP1, TP3 = 25ºC, see Note 1  
37  
41  
12  
recommended capacitive load  
(Cout)  
TP1, TP3 = 25ºC, see Note 2  
0.1  
3.5  
6
mF  
output ripple & noise (VOac  
)
See ripple & noise section, max IO , see Note 3  
TP1, TP3 = 25°C, VI = 53 V, 10-100% of max IO  
60  
150  
mVp-p  
V
over voltage protection (OVP)  
15.6  
sink current (note 4), see operating information  
trigger level, decreasing RC-voltage  
trigger level, increasing RC-voltage  
0.7  
mA  
V
V
remote control (RC)  
2.6  
2.9  
Note  
1: OCP in hic-up mode  
2: Low ESR-value  
3: Cout = 100 µF, external capacitance  
4: Sink current drawn by external device connected to the RC pin. Minimum sink current required guaranteeing activated RC function.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 6 of 30  
Typical Characteristics  
12.0 V, 35 A / 420 W  
Efficiency  
Power Dissipation  
[%]  
100  
[W]  
24  
20  
16  
12  
8
95  
90  
85  
80  
36 V  
48 V  
53 V  
36 V  
48 V  
53 V  
75 V  
75 V  
4
75  
0
0
5
10  
15  
20  
25  
30  
35 [A]  
0
5
10  
15  
20  
25  
30  
35 [A]  
Dissipated power vs. load current and input voltage at  
TP1, TP3 = +25°C  
Efficiency vs. load current and input voltage at TP1, TP3 = +25 C  
Output Characteristics  
Current Limit Characteristics  
[V]  
[V]  
13.0  
12.2  
11.0  
9.0  
7.0  
5.0  
3.0  
12.1  
36 V  
48 V  
53 V  
75 V  
36V  
48V  
53V  
75V  
12.0  
11.9  
11.8  
0
5
10  
15  
20  
25  
30  
35 [A]  
35  
37  
39  
41  
43  
45 [A]  
Output voltage vs. load current at TP1, TP3 = +25°C  
Output voltage vs. load current at IO > max IO , TP1, TP3 = +25°C  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 7 of 30  
Typical Characteristics  
12.0 V, 35 A / 420 W  
Start-up  
Shut-down  
Start-up enabled by connecting VI at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 35 A resistive load.  
Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (10 ms/div.).  
Shut-down enabled by disconnecting VI at: Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (2 ms/div.).  
TP1, TP3 = +25°C, VI = 53 V,  
IO =35 A resistive load.  
Output Ripple & Noise  
Output Load Transient Response  
Output voltage ripple at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 35 A resistive load.  
Trace: output voltage (50 mV/div.).  
Time scale: (2 µs/div.).  
Output voltage response to load current  
step-change (8.75-26.25-8.75 A) at:  
TP1, TP3 =+25°C, VI = 53 V, CO = 3.5 mF.  
Top trace: output voltage (0.5 V/div.).  
Bottom trace: output current (20 A/div.).  
Time scale: (0.5 ms/div.).  
Input Voltage Transient Response  
Output voltage response to input voltage  
transient at: TP1, TP3 = +25°C, VI = 36-75 V,  
IO = 17 A resistive load, CO = 3.5 mF  
Top trace: output voltage (2 V/div.).  
Bottom trace: input voltage (20 V/div.).  
Time scale: (0.5 ms/div.).  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 8 of 30  
Typical Characteristics  
12.0 V, 35 A / 420 W  
Output Current Derating – Open frame  
[A]  
35  
3.0 m/s  
2.0 m/s  
30  
25  
20  
15  
10  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
5
0
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Output Current Derating – Base plate  
Thermal Resistance – Base plate  
[A]  
35  
[°C/W]  
6
3.0 m/s  
30  
25  
20  
15  
10  
5
5
2.0 m/s  
1.5 m/s  
4
3
1.0 m/s  
0.5 m/s  
2
1
Nat. Con v.  
0
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0[m/s]  
0
20  
40  
60  
80  
100 [° C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Thermal resistance vs. airspeed measured at the converter. Tested in  
wind tunnel with airflow and test conditions as per the Thermal  
consideration section. VI = 53 V.  
Output Current Derating – Base plate + Heat sink  
Output Current Derating – Cold wall sealed box  
[A]  
35  
A
40  
35  
30  
25  
20  
15  
10  
5
3.0 m/s  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
1.0 m/s  
Ta mb  
85 °C  
0.5 m/s  
Nat. Conv.  
0
0
0
20  
40  
60  
80  
100 [°C]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section. Tested with Plate Fin  
Transverse heatsink, height 0.23 In, P0114 Thermal Pad.  
Available load current vs. base plate temperature at 85ºC ambient.  
VI = 53 V. See Thermal Consideration section.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 9 of 30  
Electrical Specification  
12.0 V, 39 A / 468 W  
TP1, TP3 = -40 to +90ºC, VI = 40 to 60 V.  
Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions.  
Additional Cout = 3.9 mF, Configuration File: 19010-CDA 102 0314/002  
parameter  
conditions/description  
min  
40  
typ  
max  
60  
units  
V
input voltage range (VI)  
turn-off input voltage (VIoff  
)
decreasing input voltage  
increasing input voltage  
36  
37  
39  
18  
38  
V
turn-on input voltage (VIon)  
internal input capacitance (CI)  
output power (PO)  
38  
40  
V
μF  
W
0
468  
50% of max IO  
max IO  
50% of max IO, VI = 48 V  
max IO, VI = 48 V  
96.7  
95.7  
96.8  
95.6  
%
%
%
%
efficiency (η)  
power dissipation (Pd)  
input idling power (Pli)  
input standby power (PRC)  
switching frequency (fs)  
max IO  
21.2  
2.8  
30.5  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0-100% of max IO  
0.4  
W
140  
kHz  
output voltage setting and ac-  
curacy (VOi)  
TP1 = +25°C, VI = 53 V, IO = 39 A  
0-100% of max IO  
11.88  
11.76  
12.0  
12.12  
12.24  
V
V
output voltage tolerance band  
(VO)  
line regulation (VO)  
load regulation (VO)  
max IO  
31  
5
60  
25  
mV  
mV  
VI = 53 V, 1-100% of max IO  
load transient voltage deviation VI = 53 V, load step 25-75-25% of max IO, di/dt =  
±0.4  
150  
8
V
(Vtr)  
1 A/μs  
load transient recovery time  
(ttr)  
VI = 53 V, load step 25-75-25% of max IO, di/dt =  
1 A/μs  
µs  
ramp-up time (tr) - (from  
10−90% of VOi)  
10-100% of max IO, TP1 = 25ºC, VI = 53 V  
10-100% of max IO, TP1 = 25ºC, VI = 53 V  
ms  
ms  
start-up time (ts) - (from VI  
connection to 90% of VOi)  
24  
VI shut-down fall time (tf) -  
(from VI off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
3
7
ms  
s
RC start-up time (tRC)  
max IO  
12  
ms  
RC shut-down fall time (tRC) -  
(from RC off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
4.5  
7
ms  
s
output current (IO)  
0
39  
47  
A
A
A
current limit threshold (Ilim)  
short circuit current (Isc)  
VO = 10.8 V, TP1, TP3 < max TP1, TP3  
TP1 = 25ºC, see Note 1  
41  
44  
14  
recommended capacitive load  
(Cout)  
TP1 = 25ºC, see Note 2  
0.1  
3.9  
6
mF  
output ripple & noise (VOac  
)
See ripple & noise section, max IO , see Note 3  
TP1, TP3 = 25°C, VI = 53 V, 10-100% of max IO  
50  
110  
mVp-p  
V
over voltage protection (OVP)  
15.6  
sink current (note 4), see operating information  
trigger level, decreasing RC-voltage  
trigger level, increasing RC-voltage  
0.7  
mA  
V
V
remote control (RC)  
2.6  
2.9  
Note  
1: OCP in hic-up mode  
2: Low ESR-value  
3: Cout = 100 µF, external capacitance  
4: Sink current drawn by external device connected to the RC pin. Minimum sink current required guaranteeing activated RC function.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 10 of 30  
Typical Characteristics  
12.0 V, 39 A / 468 W  
Efficiency  
Power Dissipation  
[%]  
100  
[W]  
25  
20  
15  
10  
5
95  
90  
85  
80  
40 V  
48 V  
53 V  
60 V  
40 V  
48 V  
53 V  
60 V  
0
75  
0
5
10  
15  
20  
25  
30  
35  
40 [A]  
0
5
10  
15  
20  
25  
30  
35  
40 [A]  
Dissipated power vs. load current and input voltage at  
TP1, TP3 = +25°C  
Efficiency vs. load current and input voltage at TP1, TP3 = +25 C  
Output Characteristics  
Current Limit Characteristics  
[V]  
[V]  
13.0  
12.2  
11.0  
9.0  
7.0  
5.0  
3.0  
12.1  
12.0  
11.9  
11.8  
40 V  
48 V  
53 V  
60 V  
40V  
48V  
53V  
60V  
0
5
10 15  
20 25 30  
35 40 [A]  
39  
41  
43  
45  
47 [A]  
Output voltage vs. load current at TP1, TP3 = +25°C  
Output voltage vs. load current at IO > max IO , TP1, TP3 = +25°C  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 11 of 30  
Typical Characteristics  
12.0 V, 39 A / 468 W  
Start-up  
Shut-down  
Start-up enabled by connecting VI at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 39 A resistive load.  
Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (10 ms/div.).  
Shut-down enabled by disconnecting VI at: Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (2 ms/div.).  
TP1, TP3 = +25°C, VI = 53 V,  
IO =39 A resistive load.  
Output Ripple & Noise  
Output Load Transient Response  
Output voltage ripple at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 39 A resistive load.  
Trace: output voltage (50 mV/div.).  
Time scale: (2 µs/div.).  
Output voltage response to load current  
step-change (9.75-29.25-9.75 A) at:  
TP1, TP3 =+25°C, VI = 53 V, CO = 3.9 mF.  
Top trace: output voltage (0.5 V/div.).  
Bottom trace: output current (20 A/div.).  
Time scale: (0.5 ms/div.).  
Input Voltage Transient Response  
Output voltage response to input voltage  
transient at: TP1, TP3 = +25°C, VI = 40-60 V,  
IO = 19,5 A resistive load, CO = 3.9 mF  
Top trace: output voltage (2 V/div.).  
Bottom trace: input voltage (20 V/div.).  
Time scale: (0.5 ms/div.).  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 12 of 30  
Typical Characteristics  
12.0 V, 39 A / 468 W  
Output Current Derating – Open frame  
[A]  
40  
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Output Current Derating – Base plate  
Thermal Resistance – Base plate  
[A]  
40  
[°C/W]  
6
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
5
2.0 m/s  
1.5 m/s  
4
3
1.0 m/s  
0.5 m/s  
2
1
Nat. Conv.  
0
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0[m/s]  
0
20  
40  
60  
80  
100 [° C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Thermal resistance vs. airspeed measured at the converter. Tested  
in wind tunnel with airflow and test conditions as per the Thermal  
consideration section. VI = 53 V.  
Output Current Derating – Base Plate + Heat sink  
Output Current Derating – Cold wall sealed box  
[A]  
40  
A
40  
35  
30  
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
25  
20  
15  
10  
5
Ta mb  
85 °C  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0
0
20  
40  
60  
80  
100 [° C]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section. Tested with Plate Fin  
Transverse heatsink, height 0.23 In, P0114 Thermal Pad.  
Available load current vs. base plate temperature at 85ºC ambient.  
VI = 53 V. See Thermal Consideration section.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 13 of 30  
Electrical Specification  
12.45 V, 35 A / 415 W  
TP1, TP3 = -40 to +90ºC, VI = 36 to 75 V.  
Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions.  
Additional Cout = 3.9 mF, Configuration File: 19010-CDA 102 0314/014  
parameter  
conditions/description  
min  
36  
typ  
max  
75  
units  
V
input voltage range (VI)  
turn-off input voltage (VIoff  
)
decreasing input voltage  
increasing input voltage  
32  
33  
35  
18  
34  
V
turn-on input voltage (VIon)  
internal input capacitance (CI)  
output power (PO)  
34  
36  
V
μF  
W
0
415  
50% of max IO  
max IO  
50% of max IO, VI = 48 V  
max IO, VI = 48 V  
96.2  
95.5  
96.4  
95.5  
%
%
%
%
efficiency (η)  
power dissipation (Pd)  
input idling power (Pli)  
input standby power (PRC)  
switching frequency (fs)  
max IO  
19.5  
3.2  
29.5  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0-100% of max IO  
0.4  
W
140  
kHz  
output voltage setting and ac-  
curacy (VOi)  
TP1 = 25°C, VI = 53 V, IO = 0 A  
0-100% of max IO  
12.415  
11.5  
12.45  
12.485  
12.7  
V
V
output voltage tolerance band  
(VO)  
line regulation (VO)  
load regulation (VO)  
max IO  
20  
55  
mV  
mV  
VI = 53 V, 0-100% of max IO  
500  
600  
700  
load transient voltage deviation VI = 53 V, load step 25-75-25% of max IO, di/dt =  
±0.4  
150  
23  
V
(Vtr)  
1 A/μs  
load transient recovery time  
(ttr)  
VI = 53 V, load step 25-75-25% of max IO, di/dt =  
1 A/μs  
µs  
ramp-up time (tr) - (from  
10−90% of VOi)  
10-100% of max IO, TP1, TP3 = 25ºC, VI = 53 V  
10-100% of max IO, TP1, TP3 = 25ºC, VI = 53 V  
ms  
ms  
start-up time (ts) - (from VI  
connection to 90% of VOi)  
39  
VI shut-down fall time (tf) -  
(from VI off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
3.6  
7
ms  
s
RC start-up time (tRC)  
max IO  
27  
ms  
RC shut-down fall time (tRC) -  
(from RC off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
5.1  
7
ms  
s
output current (IO)  
0
35  
44  
A
A
A
current limit threshold (Ilim)  
short circuit current (Isc)  
VO = 10.8 V, TP1, TP3 < max TP1, TP3  
TP1, TP3 = 25ºC, see Note 1  
37  
41  
12  
recommended capacitive load  
(Cout)  
TP1, TP3 = 25ºC, see Note 2  
0.1  
3.5  
6
mF  
output ripple & noise (VOac  
)
See ripple & noise section, max IO , see Note 3  
TP1, TP3 = 25°C, VI = 53 V, 10-100% of max IO  
60  
150  
mVp-p  
V
over voltage protection (OVP)  
15.6  
sink current (note 4), see operating information  
trigger level, decreasing RC-voltage  
trigger level, increasing RC-voltage  
0.7  
mA  
V
V
remote control (RC)  
2.6  
2.9  
Note  
1: OCP in hic-up mode  
2: Low ESR-value  
3: Cout = 100 µF, external capacitance  
4: Sink current drawn by external device connected to the RC pin. Minimum sink current required guaranteeing activated RC function.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 14 of 30  
Typical Characteristics  
12.45 V, 63 A / 747 W, two products in parallel  
Efficiency  
Power Dissipation  
[%]  
100  
[W]  
45  
40  
35  
30  
25  
20  
15  
10  
5
95  
90  
85  
80  
36 V  
48 V  
53 V  
36 V  
48 V  
53 V  
75 V  
75 V  
75  
0
0
0
10  
20  
30  
40  
50  
60  
[A]  
10  
20  
30  
40  
50  
60  
[A]  
Dissipated power vs. load current and input voltage at  
TP1, TP3 = +25°C  
Efficiency vs. load current and input voltage at TP1, TP3 = +25 C  
Output Characteristics  
Current Limit Characteristics  
[V]  
[V]  
13.0  
12 .5  
12 .4  
12 .3  
12 .2  
12 .1  
12 .0  
11.9  
11.0  
9.0  
36 V  
48 V  
53 V  
75 V  
36 V  
48 V  
53 V  
75 V  
7.0  
5.0  
3.0  
63 65 67 69 71 73 75 77 79 81 83 [A]  
11.8  
0
10  
20  
30  
40  
50  
60  
[A]  
Output voltage vs. load current at TP1, TP3 = +25°C  
Output voltage vs. load current at IO > max IO , TP1, TP3 = +25°C  
Start-up  
Output Load Transient Response  
Start-up enabled by connecting VI at:  
Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (10 ms/div.).  
Output voltage response to load current Top trace: output voltage (0.5 V/div.).  
step-change (15.8-47.3-15.8 A) at:  
Bottom trace: output current (20 A/div.).  
Time scale: (0.5 ms/div.).  
TP1, TP3 = +25°C, VI = 53 V,  
TP1, TP3 =+25°C, VI = 53 V, CO = 3.5 mF.  
IO = 63 A resistive load.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 15 of 30  
Typical Characteristics  
12.45 V, 35 A / 415 W  
Output Current Derating – Open frame  
[A]  
35  
3.0 m/s  
2.0 m/s  
30  
25  
20  
15  
10  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
5
0
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Output Current Derating – Base plate  
Thermal Resistance – Base plate  
[A]  
35  
[°C/W]  
6
3.0 m/s  
30  
25  
20  
15  
10  
5
5
2.0 m/s  
1.5 m/s  
4
3
1.0 m/s  
0.5 m/s  
2
1
Nat. Conv.  
0
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0[m/s]  
0
20  
40  
60  
80  
100 [° C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Thermal resistance vs. airspeed measured at the converter. Tested in  
wind tunnel with airflow and test conditions as per the Thermal  
consideration section. VI = 53 V.  
Output Current Derating – Base plate + Heat sink  
Output Current Derating – Cold wall sealed box  
[A]  
35  
A
40  
35  
30  
25  
20  
15  
10  
5
3.0 m/s  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
1.0 m/s  
Ta mb  
85 °C  
0.5 m/s  
Nat. Conv.  
0
0
0
20  
40  
60  
80  
100 [°C]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section. Tested with Plate Fin  
Transverse heatsink, height 0.23 In, P0114 Thermal Pad.  
Available load current vs. base plate temperature at 85ºC ambient.  
VI = 53 V. See Thermal Consideration section.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 16 of 30  
Electrical Specification  
12.45 V, 39 A / 462 W  
TP1, TP3 = -40 to +90ºC, VI = 40 to 60 V.  
Typical values given at: TP1, TP3 = +25°C, VI = 53 V, max IO, unless otherwise specified under Conditions.  
Additional Cout = 3.9 mF, Configuration File: 19010-CDA 102 0314/017  
parameter  
conditions/description  
min  
40  
typ  
max  
60  
units  
V
input voltage range (VI)  
turn-off input voltage (VIoff  
)
decreasing input voltage  
increasing input voltage  
36  
37  
39  
18  
38  
V
turn-on input voltage (VIon)  
internal input capacitance (CI)  
output power (PO)  
38  
40  
V
μF  
W
0
462  
50% of max IO  
max IO  
50% of max IO, VI = 48 V  
max IO, VI = 48 V  
96.7  
95.7  
96.8  
95.6  
%
%
%
%
efficiency (η)  
power dissipation (Pd)  
input idling power (Pli)  
input standby power (PRC)  
switching frequency (fs)  
max IO  
21.0  
2.8  
30.5  
W
W
IO = 0 A, VI = 53 V  
VI = 53 V (turned off with RC)  
0-100% of max IO  
0.4  
W
140  
kHz  
output voltage setting and ac-  
curacy (VOi)  
TP1 = 25°C, VI = 53 V, IO = 0 A  
0-100% of max IO  
12.415  
11.5  
12.45  
12.485  
12.7  
V
V
output voltage tolerance band  
(VO)  
line regulation (VO)  
load regulation (VO)  
max IO  
31  
60  
mV  
mV  
VI = 53 V, 0-100% of max IO  
500  
600  
700  
load transient voltage deviation VI = 53 V, load step 25-75-25% of max IO, di/dt =  
±0.4  
150  
23  
V
(Vtr)  
1 A/μs  
load transient recovery time  
(ttr)  
VI = 53 V, load step 25-75-25% of max IO, di/dt =  
1 A/μs  
µs  
ramp-up time (tr) - (from  
10−90% of VOi)  
10-100% of max IO, TP1 = 25ºC, VI = 53 V  
10-100% of max IO, TP1 = 25ºC, VI = 53 V  
ms  
ms  
start-up time (ts) - (from VI  
connection to 90% of VOi)  
39  
VI shut-down fall time (tf) -  
(from VI off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
3
7
ms  
s
RC start-up time (tRC)  
max IO  
27  
ms  
RC shut-down fall time (tRC) -  
(from RC off to 10% of VO)  
max IO  
IO = 0 A, CO = 0 mF  
4.5  
7
ms  
s
output current (IO)  
0
39  
47  
A
A
A
current limit threshold (Ilim)  
short circuit current (Isc)  
VO = 10.8 V, TP1, TP3 < max TP1, TP3  
TP1 = 25ºC, see Note 1  
41  
44  
14  
recommended capacitive load  
(Cout)  
TP1 = 25ºC, see Note 2  
0.1  
3.9  
6
mF  
output ripple & noise (VOac  
)
See ripple & noise section, max IO , see Note 3  
TP1, TP3 = 25°C, VI = 53 V, 10-100% of max IO  
50  
110  
mVp-p  
V
over voltage protection (OVP)  
15.6  
sink current (note 4), see operating information  
trigger level, decreasing RC-voltage  
trigger level, increasing RC-voltage  
0.7  
mA  
V
V
remote control (RC)  
2.6  
2.9  
Note  
1: OCP in hic-up mode  
2: Low ESR-value  
3: Cout = 100 µF, external capacitance  
4: Sink current drawn by external device connected to the RC pin. Minimum sink current required guaranteeing activated RC function.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 17 of 30  
Typical Characteristics  
12.45 V, 70 A / 830 W, two products in parallel  
Efficiency  
Power Dissipation  
[%]  
100  
[W]  
45  
40  
35  
30  
25  
20  
15  
10  
5
95  
90  
85  
80  
40 V  
48 V  
53 V  
60 V  
40 V  
48 V  
53 V  
60 V  
75  
0
0
[A]  
70  
10  
20  
30  
40  
50  
60  
70 [A]  
0
10  
20  
30  
40  
50  
60  
Dissipated power vs. load current and input voltage at  
TP1, TP3 = +25°C  
Efficiency vs. load current and input voltage at TP1, TP3 = +25 C  
Output Characteristics  
Current Limit Characteristics  
[V]  
[V]  
13.0  
12.5  
12.4  
12.3  
12.2  
12.1  
12.0  
11.0  
9.0  
7.0  
5.0  
3.0  
40 V  
48 V  
53 V  
60 V  
40 V  
48 V  
53 V  
60 V  
11.9  
11.8  
70  
75  
80  
85  
90 [A]  
0
10  
20  
30  
40  
50  
60  
70 [A]  
Output voltage vs. load current at TP1, TP3 = +25°C  
Output voltage vs. load current at IO > max IO , TP1, TP3 = +25°C  
Start-up  
Output Load Transient Response  
Start-up enabled by connecting VI at:  
TP1, TP3 = +25°C, VI = 53 V,  
IO = 70 A resistive load.  
Top trace: output voltage (5 V/div.).  
Bottom trace: input voltage (50 V/div.).  
Time scale: (10 ms/div.).  
Output voltage response to load current Top trace: output voltage (0.5 V/div.).  
step-change (17.5-52.5-17.5 A) at:  
Bottom trace: output current (20 A/div.).  
Time scale: (0.5 ms/div.).  
TP1, TP3 =+25°C, VI = 53 V, CO = 3.9 mF  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 18 of 30  
Typical Characteristics  
12.45 V, 39 A / 462 W  
Output Current Derating – Open frame  
[A]  
40  
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Output Current Derating – Base plate  
Thermal Resistance – Base plate  
[A]  
40  
[°C/W]  
6
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
5
2.0 m/s  
1.5 m/s  
4
3
1.0 m/s  
0.5 m/s  
2
1
Nat. Conv.  
0
0
0.0  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0[m/s]  
0
20  
40  
60  
80  
100 [° C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section.  
Thermal resistance vs. airspeed measured at the converter. Tested  
in wind tunnel with airflow and test conditions as per the Thermal  
consideration section. VI = 53 V.  
Output Current Derating – Base Plate + Heat sink  
Output Current Derating – Cold wall sealed box  
[A]  
40  
A
40  
35  
30  
25  
20  
15  
10  
5
3.0 m/s  
35  
30  
25  
20  
15  
10  
5
2.0 m/s  
1.5 m/s  
Ta mb  
85 °C  
1.0 m/s  
0.5 m/s  
Nat. Conv.  
0
0
0
20  
40  
60  
80  
100 [° C]  
0
20  
40  
60  
80  
100 [°C]  
Available load current vs. ambient air temperature and airflow at  
VI = 53 V. See Thermal Consideration section. Tested with Plate Fin  
Transverse heatsink, height 0.23 In, P0114 Thermal Pad.  
Available load current vs. base plate temperature at 85ºC ambient.  
VI = 53 V. See Thermal Consideration section.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 19 of 30  
EMC Specification  
Conducted EMI measured according to EN55022, CISPR  
22 and FCC part 15J (see test set-up). The fundamental  
switching frequency is 140 kHz for NQB at VI = 53 V, max  
IO.  
Conducted EMI Input terminal value (typ)  
Test set-up  
Layout recommendations  
The radiated EMI performance of the product will  
depend on the PWB layout and ground layer design.  
It is also important to consider the stand-off of  
the product. If a ground layer is used, it should  
be connected to the output of the product and the  
equipment ground or chassis.  
A ground layer will increase the stray capacitance  
in the PWB and improve the high frequency EMC  
performance.  
EMI without filter  
Output ripple and noise  
Output ripple and noise measured according to figure  
below.  
Optional external filter for class B  
Suggested external input filter in order to meet class B in  
EN 55022, CISPR 22 and FCC part 15J.  
Filter components:  
C1 = 1 μF  
C2 = 1 μF+220 μF  
0
C3 = 1 μF+220 μF  
C4  
L1  
L2  
C4,C5 = 2.2 nF  
L1 = 810 μH  
L2 = 810 μH  
+
+
C1  
C2  
C3  
R
Module  
-
-
C5  
0
Output ripple and noise test setup  
Operating information  
Power Management Overview  
This product includes protection features that  
continuously safeguard the load from damage due to  
unexpected system faults.  
Input Voltage  
The NQB consists of two different product families  
designed for two different input voltage ranges, 36 to  
75 Vdc and 40 to 60 Vdc, see ordering information.  
The input voltage range 36 to 75 Vdc meets the  
requirements of the European Telecom Standard ETS  
300 132-2 for normal input voltage range in –48 and  
EMI with filter  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 20 of 30  
capacitors are used to handle low frequency dynamic load  
changes. Ceramic capacitors will also reduce any high  
frequency noise at the load. It is equally important to  
use low resistance and low inductance PWB layouts and  
cabling. External decoupling capacitors will become part  
of the product’s control loop. The control loop is optimized  
for a wide range of external capacitance and the maximum  
recommended value that could be used without any  
additional analysis is found in the electrical specification.  
The ESR of the capacitors is a very important parameter.  
Stable operation is guaranteed with a verified ESR value  
of >10 mΩ across the output connections. For further  
information please contact your local CUI Power Modules  
representative.  
–60 Vdc systems, -40.5 to -57.0 V and –50.0 to -72 V  
respectively.  
At input voltages exceeding 75 V, the power loss will  
be higher than at normal input voltage and TP1 must be  
limited to absolute max +125°C. The absolute maximum  
continuous input voltage is 80 Vdc.  
The input voltage range 40 to 60 Vdc meets the  
requirements for normal input voltage range in -48 V  
systems, -40.5 to -57.0 V. At input voltages exceeding  
60 V, the power loss will be higher than at normal input  
voltage and TP1 must be limited to absolute max +125°C.  
The absolute maximum continuous input voltage is 65 Vdc.  
Turn-off Input Voltage  
Parallel Operation (Droop Load Share, DLS)  
The NQB, DLS products are variants that can be connected  
in parallel. The products have a pre-configured voltage  
droop: The stated output voltage set point is at no load.  
The output voltage will decrease when the load current is  
increased. The voltage will droop 0.6 V while load reaches  
max load. This feature allows the products to be connected  
in parallel and share the current with 10% accuracy. Up  
to 90% of max output current can be used from each  
product.  
The product monitors the input voltage and will turn  
on and turn off at predetermined levels. The minimum  
hysteresis between turn on and turn off input voltage is 2  
V.  
Remote Control (RC)  
The products are fitted with a remote control function.  
The remote control is referenced to the primary negative  
input connection (-In). The RC function allows the  
converter to be turned on/off by an external device like a  
semiconductor or mechanical switch. The RC pin has an  
internal pull up resistor. The device should be capable of  
sinking 0.7 mA. When the RC pin is left open, the voltage  
generated on the RC pin is max  
Voltage regulation DLS products  
12.8  
Module 1  
6 V. The product is provided with  
“negative logic” remote control  
and will be off until the RC pin is  
Module 2  
12.6  
Module 1+2  
12.4  
connected to the -In. To turn on  
the product the voltage between  
RC pin and -In should be less  
than 1 V. To turn off the product  
the RC pin should be left open for  
a minimum of time 150 µs, the  
12.2  
12.0  
11.8  
11.6  
0
10  
20  
30  
40  
50  
60  
70  
same time requirement applies  
when the product shall turn on. In  
Output Current [A]  
situations where it is desired to have the product to power  
up automatically without the need for control signals or a  
switch, the RC pin can be wired directly to –In  
Feed Forward Capability  
The NQB products have a feed forward function  
implemented that can handle sudden input voltage  
changes. The output voltage will be regulated during an  
input transient and will typically stay within 10% when an  
input transient is applied.  
Input and Output Impedance  
The impedance of both the input source and the load will  
interact with the impedance of the product. It is important  
that the input source has low characteristic impedance.  
Minimum recommended external input capacitance is 100  
µF. The performance in some applications can be enhanced  
by addition of external capacitance as described under  
External Decoupling Capacitors.  
Soft-start Power Up  
The rise time of the ramp up is 10 ms. When starting by  
applying input voltage the control circuit boot-up time  
adds an additional 15 ms delay. The DLS variants have a  
pre-configured ramp up time of  
External Decoupling Capacitors  
25 ms.  
When powering loads with significant dynamic current  
requirements, the voltage regulation at the point of load  
can be improved by addition of decoupling capacitors at  
the load. The most effective technique is to locate low ESR  
ceramic and electrolytic capacitors as close to the load  
as possible, using several parallel capacitors to lower the  
effective ESR. The ceramic capacitors will handle high-  
frequency dynamic load changes while the electrolytic  
Temperature Protection (OTP, UTP)  
The products are protected from thermal overload by an  
internal temperature shutdown protection. When TP1 as  
defined in thermal consideration section is exceeded the  
product will shut down. The product will make continuous  
attempts to start up and resume normal operation  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 21 of 30  
automatically when the temperature has dropped below  
Thermal Consideration  
the temperature threshold; the hysteresis is defined in  
general electrical specification. The product has also an  
under temperature protection.  
General  
The product is designed to operate in different thermal  
environments and sufficient cooling must be provided  
to ensure reliable operation. For products mounted on  
a PWB without a heat sink attached, cooling is achieved  
mainly by conduction, from the pins to the host board,  
and convection, which is dependant on the airflow across  
the product. Increased airflow enhances the cooling of  
the product. The Output Current Derating graph found in  
the output section for each model provides the available  
output current vs. ambient air temperature and air velocity  
at VI =53 V.  
Over Voltage Protection (OVP)  
The product includes over voltage limiting circuitry for  
protection of the load. The OVP limit is 30% above the  
nominal output voltage. The response from an over  
voltage fault is to immediately shut down. The device will  
continuously check for the presence of the fault condition,  
and when the fault condition no longer exists the device  
will be re-enabled.  
Over Current Protection (OCP)  
The product includes current limiting circuitry for  
protection at continuous overload. The setting for the  
product is hic-up mode if the maximum output current is  
exceeded and the output voltage is below 0.3×Vout. Above  
the trip voltage the product will continue operate while  
maintaining the output current at the maximum output  
current. The load distribution should be designed for the  
maximum output short circuit current specified.  
The product is tested on a 254 x 254 mm, 35 µm (1 oz),  
16-layer test board mounted vertically in a wind tunnel  
with a cross-section of 608 x 203 mm.  
Droop Load Share variants (DLS) will enter hic-up mode,  
with a trip voltage, 0.04×Vout. Above the trip voltage the  
product will continue to operate while maintaining the  
output current at the maximum output current  
Input Over/Under voltage protection  
The input of the product is protected from high input  
voltage and low input voltage.  
Pre-bias Start-up Capability  
The product has a Pre-bias start up functionality and will  
not sink current during start up if a Pre-bias source is  
present at the output terminals. If the Pre-bias voltage  
is lower than the target value, the product will ramp up  
to the target value. If the Pre-bias voltage is higher than  
the target value, the product will ramp down to the target  
value and in this case sink current for a limited time.  
For products with base plate used in a sealed box/cold  
wall application, cooling is achieved mainly by conduction  
through the cold wall. The Output Current Derating graphs  
are found in the output section for each model. The  
product is tested in a sealed box test set up with ambient  
temperatures 85, 55 and 25°C.  
Output Voltage Regulation  
The NQB products are designed to be fully regulated  
within the plotted area. Operating outside this area is not  
recommended.  
13.4  
13.2  
13.0  
12.8  
12.6  
12.4  
12.2  
12.0  
13.4  
13.2  
13.0  
12.8  
12.6  
12.4  
12.2  
12.0  
35 45 55 65 75  
Vin [V]  
35 40 45 50 55 60 65  
Vin [V]  
Vin range: 36-75Vdc  
Vin range:40-60Vdc  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 22 of 30  
Definition of product operating temperature  
Resistance graph found in the Output section for  
each model. Note that the thermal resistance can be  
significantly reduced if a heat sink is mounted on the top  
The product operating temperature is used to monitor the  
temperature of the product, and proper thermal conditions  
can be verified by measuring the temperature at positions  
P1, P2, P3 and P4. The temperature at these positions (TP1,  
of the base plate.  
TP2, TP3, TP4) should not exceed the maximum temperatures Calculate the temperature increase (ΔT).  
in the table below. The number of measurement points  
may vary with different thermal design and topology.  
Temperatures above maximum TP1, measured at the  
ΔT = Rth x Pd  
3. Max allowed ambient temperature is:  
Max TP1 - ΔT.  
reference point P1 (TP3  
/
for base plate versions) are not  
P3  
allowed and may cause permanent damage.  
E.g. NQB-468 at 2m/s:  
Position  
Description  
PWB (reference point, open  
frame)  
Max temperature  
TP1=125º C  
1. ((1/0.95) - 1) × 468 W = 24.6 W  
2. 19.5 W × 2.8°C/W = 69.0°C}  
P1  
P2  
P3  
P4  
Opto-coupler  
TP2=105º C  
PWB (reference point for  
base-plate version)  
TP3=125º C  
3. 125 °C - 69.0°C = max ambient temperature is 56°C  
The actual temperature will be dependent on several  
factors such as the PWB size, number of layers and  
direction of airflow.  
Primary MOSFET  
TP4=125º C  
Connections (Top view)  
Top view  
Pin  
1
Designation  
+In  
Function  
Positive Input  
2
3
4
5
RC  
Case  
-In  
-Out  
+Out  
Remote Control  
Case to GND (optional)  
Negative Input  
Negative Output  
Positive Output  
16  
Bottom view  
(Best air flow direction is from positive to negative pins.)  
Ambient Temperature Calculation  
For products with base plate the maximum allowed  
ambient temperature can be calculated by using the  
thermal resistance.  
1. The power loss is calculated by using the formula  
((1/η) - 1) × output power = power losses (Pd).  
η = efficiency of product. E.g. 95 % = 0.95  
2. Find the thermal resistance (Rth) in the Thermal  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 23 of 30  
Mechanical Information - Hole Mount, Open Frame Version  
Top View  
Pin Positions According To Recommended Footprint  
Table ꢀ.  
Xꢀ = Ordering information  
PIN SPECIFICATIONS  
Pin ꢀ, 2, 4, 5 & ꢀ6 Material: Copper alloy  
Plating: Min Au 0.ꢀ µm over ꢀ-3 µm Ni.  
Pin position 3 is only used for base plate  
GND connection which is not available on  
this module.  
Recommended Footprint - Top View  
Weight: Typical 48 g  
All dimensions: mm [inch]  
Tolerances:  
x.x 0.50 [0.02]  
x.xx 0.25 [0.0ꢀ]  
(not applied on footprint or typical values)  
Recommended keep away area for user components.  
The stand-off in combination with insulating material ensures that requirements  
as per IEC/EN/UL60950 are met and 2250 V isolation maintained even if open  
vias or traces are present under the DC/DC converter.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 24 of 30  
Mechanical Information - Hole Mount, Base Plate Version  
Top View  
Pin Positions According To Recommended Footprint  
Table ꢀ.  
Xꢀ = Ordering information  
CASE  
Material: Aluminum  
For screw attachment apply mounting  
torque of max 0.44 Nm [3.9 lbf in]. M3  
screws must not protrude more than  
2.7mm [0.ꢀ06] into the base plate.  
PIN SPECIFICATIONS  
Pin ꢀ, 2, 3, 4, 5 & ꢀ6 Material: Copper alloy  
Plating: Min Au 0.ꢀ µm over ꢀ-3 µm Ni.  
Recommended Footprint - Top View  
Pin position 3 is only used for base plate  
GND connection.  
Weight: Typical 68 g  
All dimensions: mm [inch]  
Tolerances:  
x.x 0.50 [0.02]  
x.xx 0.25 [0.0ꢀ]  
(not applied on footprint or typical values)  
Recommended keep away area for user components.  
The stand-off in combination with insulating material ensures that requirements  
as per IEC/EN/UL60950 are met and 2250 V isolation maintained even if open  
vias or traces are present under the DC/DC converter.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 25 of 30  
Mechanical Information - Surface Mount Version  
Top View  
Pin Positions According To Recommended Footprint  
Recommended Footprint - Top View  
PIN SPECIFICATIONS  
Pin ꢀ, 2, 4, 5 & ꢀ6 Material: Copper alloy  
Plating: Min Au 0.ꢀ µm over ꢀ-3 µm Ni.  
Weight: Typical 46 g  
All dimensions: mm [inch]  
Tolerances:  
x.x 0.50 [0.02]  
x.xx 0.25 [0.0ꢀ]  
(not applied on footprint or typical values)  
Recommended keep away area for user components.  
The stand-off in combination with insulating material ensures that requirements  
as per IEC/EN/UL60950 are met and 2250 V isolation maintained even if open  
vias or traces are present under the DC/DC converter.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 26 of 30  
Lead-free (Pb-free) solder processes  
Soldering Information - Surface Mounting  
For Pb-free solder processes, a pin temperature (TPIN  
)
in excess of the solder melting temperature (TL, 217 to  
221°C for SnAgCu solder alloys) for more than 60 seconds  
and a peak temperature of 245°C on all solder joints is  
recommended to ensure a reliable solder joint.  
The surface mount product is intended for forced  
convection or vapor phase reflow soldering in SnPb and  
Pb-free processes.  
The reflow profile should be optimised to avoid excessive  
heating of the product. It is recommended to have  
a sufficiently extended preheat time to ensure an  
even temperature across the host PWB and it is also  
recommended to minimize the time in reflow.  
Maximum Product Temperature Requirements  
Top of the product PWB near pin 2 is chosen as reference  
location for the maximum (peak) allowed product  
temperature (TPRODUCT) since this will likely be the warmest  
part of the product during the reflow process.  
A no-clean flux is recommended to avoid entrapment of  
cleaning fluids in cavities inside the product or between  
the product and the host board, since cleaning residues  
may affect long time reliability and isolation voltage.  
SnPb solder processes  
For SnPb solder processes, the product is qualified for MSL  
1 according to IPC/JEDEC standard J STD 020C.  
During reflow TPRODUCT must not exceed 225 °C at any time.  
Pb-free  
General reflow process specifications SnPb eutectic  
Average ramp-up (TPRODUCT  
)
3°C/s max  
183°C  
3°C/s max  
Pb-free solder processes  
Typical solder melting (liquidus)  
temperature  
TL  
221°C  
For Pb-free solder processes, the product is qualified for  
MSL 3 according to IPC/JEDEC standard J-STD-020C.  
Minimum reflow time above TL  
Minimum pin temperature  
Peak product temperature  
60 s  
60 s  
TPIN  
210°C  
235°C  
TPRODUCT  
225°C  
260°C  
During reflow TPRODUCT must not exceed 260 °C at any time.  
Average ramp-down (TPRODUCT  
Maximum time 25°C to peak  
)
6°C/s max  
6 minutes  
6°C/s max  
8 minutes  
Dry Pack Information  
Products intended for Pb-free reflow soldering processes  
are delivered in standard moisture barrier bags according  
to IPC/JEDEC standard J STD 033 (Handling, packing,  
shipping and use of moisture/reflow sensitivity surface  
mount devices).  
Temperature  
TPRODUCT maximum  
TPIN minimum  
Pin  
profile  
TL  
Product  
profile  
Using products in high temperature Pb-free soldering  
processes requires dry pack storage and handling. In  
case the products have been stored in an uncontrolled  
environment and no longer can be considered dry, the  
modules must be baked according to J STD 033.  
Time in  
reflow  
Time in preheat  
/ soak zone  
Time 25°C to peak  
Time  
Thermocoupler Attachment  
Minimum Pin Temperature Recommendations  
Top of PWB near pin 2 for measurement of maximum  
product temperature, TPRODUCT  
Pin number 5 chosen as reference location for the  
minimum pin temperature recommendation since this will  
likely be the coolest solder joint during the reflow process.  
SnPb solder processes  
For SnPb solder processes, a pin temperature (TPIN) in  
excess of the solder melting temperature, (TL, 183°C  
for Sn63Pb37) for more than 60 seconds and a peak  
temperature of 220°C is recommended to ensure a reliable  
solder joint.  
For dry packed products only: depending on the type of  
solder paste and flux system used on the host board, up to  
a recommended maximum temperature of 245°C could be  
used, if the products are kept in a controlled environment  
(dry pack handling and storage) prior to assembly.  
Pin 5 for measurement of minimum pin (solder joint )  
temperature, TPIN  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 27 of 30  
Soldering Information - Hole Mounting  
The hole mounted product is intended for plated through  
hole mounting by wave or manual soldering. The pin  
temperature is specified to maximum to 270°C for  
maximum 10 seconds.  
A maximum preheat rate of 4°C/s and maximum preheat  
temperature of 150°C is suggested. When soldering by  
hand, care should be taken to avoid direct contact between  
the hot soldering iron tip and the pins for more than a few  
seconds in order to prevent overheating.  
A no-clean flux is recommended to avoid entrapment of  
cleaning fluids in cavities inside the product or between  
the product and the host board. The cleaning residues may  
affect long time reliability and isolation voltage.  
Delivery Package Information  
The products are delivered in antistatic injection molded  
trays (Jedec design guide 4.10D standard) and in antistatic  
trays.  
Tray Specifications – SMD  
Material  
Surface resistance  
Antistatic PPE  
105 < Ohm/square < 1012  
The trays can be baked at maximum  
125°C for 48 hours  
Bakability  
Tray thickness  
Box capacity  
Tray weight  
14.50 mm 0.571 [ inch]  
20 products (2 full trays/box)  
125 g empty, 574 g full tray  
JEDEC standard tray for 2x5 = 10 products.  
All dimensions in mm [inch]  
Tolerances: X.x ±0.26 [0.01], X.xx ±0.13 [0.005]  
Note: pick up positions refer to center of pocket.  
See mechanical drawing for exact location on product.  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 28 of 30  
Tray Specifications - TH  
Material  
PE Foam  
Surface  
105 < Ohm/square < 1012  
resistance  
Bakability  
Tray capacity  
Box capacity  
The trays are not bakeable  
20 converters/tray  
20 products (1 full tray/box)  
Product – Open frame  
1100 g full tray, 140g empty tray  
Product – Base plate option  
1480 g full tray, 140 g empty tray  
Weight  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 29 of 30  
Product Qualification Specification  
Characteristics  
External visual inspection  
IPC-A-610  
Temperature range  
Number of cycles  
Dwell/transfer time  
-40 to 100°C  
500  
15 min/0-1 min  
Change of temperature  
(Temperature cycling)  
IEC 60068-2-14 Na  
Temperature TA  
Duration  
Temperature  
Humidity  
Duration  
-45°C  
72 h  
85°C  
85 % RH  
1000 hours  
125°C  
1000 h  
Cold (in operation)  
Damp heat  
IEC 60068-2-1 Ad  
IEC 60068-2-67 Cy  
IEC 60068-2-2 Bd  
Temperature  
Duration  
Dry heat  
Electrostatic discharge  
susceptibility  
IEC 61340-3-1, JESD 22-A114  
IEC 61340-3-2, JESD 22-A115  
Human body model (HBM)  
Machine Model (MM)  
Class 2, 2000 V  
Class 3, 200 V  
Water  
Glycol ether  
Isopropyl alcohol  
55°C  
35°C  
35°C  
Immersion in cleaning solvents  
IEC 60068-2-45 XA, method 2  
Peak acceleration  
Duration  
100 g  
6 ms  
Mechanical shock  
IEC 60068-2-27 Ea  
Level 1 (SnPb-eutectic)  
Level 3 (Pb Free)  
225°C  
260°C  
Moisture reflow sensitivity 1  
J-STD-020C  
Operational life test  
MIL-STD-202G, method 108A  
IEC 60068-2-20 Tb, method 1A  
Duration  
1000 h  
Solder temperature  
Duration  
270°C  
10-13 s  
Resistance to soldering heat 2  
IEC 60068-2-21 Test Ua1  
IEC 60068-2-21 Test Ue1  
Through hole mount products  
Surface mount products  
All leads  
All leads  
Robustness of terminations  
Preconditioning  
150°C dry bake 16 h  
215°C  
Temperature, SnPb Eutectic  
Temperature, Pb-free  
IEC 60068-2-58 test Td 1  
IEC 60068-2-20 test Ta 2  
235°C  
Solderability  
Preconditioning  
Temperature, SnPb Eutectic  
Temperature, Pb-free  
Steam ageing  
235°C  
245°C  
Frequency  
Spectral density  
Duration  
10 to 500 Hz  
Vibration, broad band random  
IEC 60068-2-64 Fh, method 1  
0.07 g2/Hz  
10 min in each direction  
Notes:  
1. Only for products intended for reflow soldering (surface mount products)  
2. Only for products intended for wave soldering (plated through hole products)  
cui.com  
CUI Inc SERIES: NQB-N DESCRIPTION: FULLY REGULATED ADVANCED BUS CONVERTERS  
date 02/20/2013 page 30 of 30  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
02/20/2013  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
Novum is a trademark of CUI.  
All other trademarks are the property of their respective owners.  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  

相关型号:

NQB-100NWA-DAPH-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DBNH-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DBNL-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DBPH-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DCNH-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DCNL-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DCPH-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DDNH-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DDNL-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DDPH-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DSNH-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI

NQB-100NWA-DSNL-000-ESA

FULLY REGULATED ADVANCED BUS CONVERTERS
CUI