SERIES: PBO-10C DESCRIPTION: INTERNAL AC-DC POWER SUPPLY  
FEATURES  
• wide input range (85 ~ 305 Vac)  
• wide operating temperature range (-40 to +85 C)  
• IEC/EN/UL 62368 certified  
• designed to meet 61558 & 60335 safety standards  
• 1,000,000 hour MTBF  
• flexible implementations to power a wide array of applications  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
and noise¹  
efficiency²  
MODEL  
typ  
typ  
(Vdc)  
3.3  
(A)  
(W)  
(mVp-p)  
(%)  
PBO-10C-3  
PBO-10C-5  
PBO-10C-9  
PBO-10C-12  
PBO-10C-15  
PBO-10C-24  
2.0  
2.0  
6.6  
150  
150  
150  
150  
150  
150  
73.0  
77.0  
80.0  
82.0  
82.0  
83.0  
5.0  
10.0  
10.0  
10.0  
10.0  
10.0  
9.0  
1.1  
12.0  
15.0  
24.0  
0.83  
0.67  
0.42  
Note:  
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, see Application Circuit.  
2. At 230 Vac input.  
PART NUMBER KEY  
PBO-10C - XX  
Output Voltage  
Base Number  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PBO-10C DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2020 page 2 of 8  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
ac input  
dc input  
85  
100  
305  
430  
Vac  
Vdc  
voltage  
frequency  
current  
47  
63  
Hz  
at 115 Vac  
at 230 Vac  
0.30  
0.18  
A
A
at 115 Vac  
at 277 Vac  
15  
30  
A
A
inrush current  
at 230 Vac  
3.3 & 5 Vdc output models  
9, 12 & 15 Vdc output models  
24 Vdc output models  
0.10  
0.12  
0.15  
W
W
W
no load power consumption  
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
3.3 Vdc output models  
5 Vdc output models  
9 Vdc output models  
12 Vdc output models  
15 Vdc output models  
24 Vdc output models  
1,500  
1,500  
1,000  
680  
470  
330  
μF  
μF  
μF  
μF  
μF  
μF  
capacitive load  
3.3 Vdc output  
other outputs  
±3  
±2  
%
%
initial set point accuracy  
line regulation  
at rated load  
±1  
%
%
load regulation  
0% ~ 100% load  
±1.5  
±0.02  
temperature coefficient  
%/°C  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
output voltage clamp & hiccup  
3.3 & 5 Vdc output models  
9 Vdc output models  
12 Vdc output models  
15 Vdc output models  
24 Vdc output models  
9.0  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
15.0  
16.0  
21.0  
32.0  
over voltage protection  
over current protection  
short circuit protection  
auto recovery  
110  
%
continuous, auto recovery, hiccup  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
isolation voltage  
input to output for 1 minute, leakage current <5mA  
3,000  
Vac  
certified to 62368: IEC/EN/UL  
designed to meet 61558: IEC, EN  
safety approvals  
designed to meet 60335: IEC, EN  
safety class  
EMI/EMC  
class II  
CISPR32/EN55032 CLASS A (Recommended circuit 1, 4)  
CISPR32/EN55032 CLASS B (Recommended circuit 2, 3)  
ESD  
IEC/EN 61000-4-2 Contact ±6KV perf. Criteria B  
IEC/EN61000-4-3 10V/m perf. Criteria A  
radiated immunity  
IEC/EN61000-4-4 ±2KV (Recommended circuit 1, 2) perf. Criteria B  
IEC/EN61000-4-4 ±4KV (Recommended circuit 3, 4) perf. Criteria B  
EFT/burst  
IEC/EN61000-4-5 line to line ±1KV (Recommended circuit 1, 2) perf. Criteria B  
IEC/EN61000-4-5 line to line±2KV (Recommended circuit 3, 4) perf. Criteria B  
surge  
conducted immunity  
IEC/EN61000-4-6 10Vr.m.s perf. Criteria A  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PBO-10C DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2020 page 3 of 8  
(
)
SAFETY & COMPLIANCE CONTINUED  
parameter  
conditions/description  
min  
typ  
typ  
max  
units  
voltage dips and interruptions  
IEC/EN61000-4-11 0%, 70% perf. Criteria B  
as per MIL-HDBK-217F at 25 °C  
yes  
MTBF  
RoHS  
1,000,000  
hours  
ENVIROMENTAL  
parameter  
conditions/description  
min  
-40  
-40  
max  
85  
units  
°C  
operating temperature  
storage temperature  
storage humidity  
105  
95  
°C  
%
DERATING CURVES  
EFFICIENCY CURVES  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PBO-10C DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2020 page 4 of 8  
MECHANICAL  
parameter  
dimensions  
weight  
conditions/description  
min  
typ  
max  
units  
mm  
g
32.00 x 17.20 x 15.05 (1.259 x 0.677 x 0.592 inches)  
8.2  
cooling  
free air convection  
MECHANICAL DRAWING  
units: mm [inch]  
general tolerance: ±1.00 [±0.039]  
PIN CONNECTIONS  
PIN  
1
Function  
AC (N)  
AC (L)  
+V (cap)  
-V (cap)  
-Vo  
2
3
4
5
6
+Vo  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PBO-10C DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2020 page 5 of 8  
APPLICATION DESIGN REFERENCE  
PBO-10C Series additional component selection guide (no EMC devices)  
C11  
(required)  
C2  
(required)  
L1  
C32  
(required)  
CY1  
TVS3  
Part no.  
C4  
(required)  
(required)  
PBO-10C-3  
PBO-10C-5  
PBO-10C-9  
PBO-10C-12  
PBO-10C-15  
PBO-10C-24  
SMBJ7.0A  
SMBJ7.0A  
8ꢀ0μF/ꢁ6V  
(solid-state capacitor)  
ꢀ.ꢀμH  
max ꢁ5mΩ/6.5A  
ꢁ50μF/ꢂ5V  
ꢀꢀ0μF/ꢂ5V  
0.ꢁμF/50V  
(ceramic  
capacitor)  
SMBJ12A  
1.0nF/400Vac  
270uF/16V  
(solid-state capacitor)  
ꢀꢀμF/450V  
SMBJ20A  
SMBJ20A  
SMBJ30A  
470uF/35V  
Note:  
1. Recommended to use a capacitor with ripple current >300 mA at 100 kHz.  
2. Recommended to use a high frequency, low ESR, electrolytic capacitor with at least 20% margin on voltage rating.  
3. A suppressor diode (TVS) is recommended to protect the downstream application in case of converter failure and should be rated for a minimum of 1.2 times  
the converter’s output voltage.  
PBO-10C Series Enviromental and EMC selection guide  
Recommended  
Application  
enviromental  
Typical  
industry  
Input voltage  
range  
Enviroment  
temperature  
Emissions  
Class A  
Immunity  
Class III  
circuit  
1
Basic application  
None  
-40°C to 85°C  
-25°C to 55°C  
Indoor civil  
enviroment  
Smart home/Home  
appliances (2 Y-caps)  
2
Class B  
Class III  
Intelligent building/  
Intelligent  
Indoor general  
enviroment  
agriculture  
85~305Vac  
3
4
Indoor industrial  
Manufacturing workoshop  
-25°C to 55°C  
-40°C to 85°C  
Class B  
Class A  
Class IV  
Class IV  
ITS/Video monitoring/  
Charging point/Com-  
munication/Security and  
protection  
Outdoor general  
enviroment  
Immunity design circuits reference  
Class III Class IV  
Emissions design circuits reference  
Class A Class B  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PBO-10C DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2020 page 6 of 8  
APPLICATION DESIGN REFERENCE (CONTINUED)  
Circuit 1  
Table 1  
Application enviromental  
Basic application  
Ambient temperature range  
-40°C ~ 85°C  
Imunity Class  
Class III  
Emissions Class  
Class A  
Component  
FUSE (required)  
Recommended value  
1A/300V, slow blow  
6.8Ω/ꢂW  
R1 (wire-wound resistor, required)  
LDM  
ꢀ.ꢀmH/4Ω max/0.ꢀ4A min  
Note: Rꢁ must be a wire-wound resistor; do not use a chip or carbon film resistor.  
Circuit 2  
Table 2  
Application enviromental  
Indoor civil / general  
Ambient temperature range  
-25°C ~ 55°C  
Imunity Class  
Class III  
Emissions Class  
Class B  
Component  
FUSE (required)  
Recommended value  
1A/300V, slow-blow  
6.8Ω/ꢂW  
R1 (wire-wound resistor, required)  
CY1 (CY2)  
LDM  
1.0nF/400Vac  
ꢀ.ꢀmH/ 4Ω/0.ꢀ4A  
0.1µF/310Vac  
CX  
Note:  
1. For Smart Home and Home Appliance applications two Y-capacitors are required in series (2.2 nF/250 Vac each) to meet 60335 household safety requirements.  
ꢀ. Many safety standards require a bleeder resistor no greater than ꢂ.8MΩ in parallel with the X-capacitor.  
3. R1 must be a wire-wound resistor; do not use a chip or carbon film resistor.  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PBO-10C DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2020 page 7 of 8  
APPLICATION DESIGN REFERENCE (CONTINUED)  
Circuit 3  
Table 3  
Application enviromental  
Indoor industrial  
Ambient temperature range  
-25°C ~ 55°C  
Imunity Class  
Class IV  
Emissions Class  
Class B  
Component  
Recommended value  
FUSE (required)  
2A/300V, slow-blow  
S14K350  
MOV  
CY1  
CX  
1.0nF/400Vac  
0.1µF/310Vac  
ꢀ.ꢀmH/ 4Ω/0.ꢀ4A  
6.8Ω/ꢂW  
LDM  
R1 (wire-wound resistor, required)  
Note: ꢁ. Many safety standards require a bleeder resistor no greater than ꢂ.8MΩ in parallel with the X-capacitor.  
2. R1 must be a wire-wound resistor; do not use a chip or carbon film resistor.  
Circuit 4  
Table 4  
Application enviromental  
Ambient temperature range  
-40°C ~ 85°C  
Imunity Class  
Class IV  
Emissions Class  
Class A  
Oudoor general enviroment  
Component  
Recommended value  
FUSE (required)  
2A/300V, slow-blow  
S14K350  
MOV  
LDM  
ꢀ.ꢀmH/ 4Ω/0.ꢀ4A  
6.8Ω/ꢂW  
R1 (wire-wound resistor, required)  
Note: R1 must be a wire-wound resistor; do not use a chip or carbon film resistor.  
cui.com  
Additional Resources: Product Page  
|
3D Model  
|
PCB Footprint  
CUI Inc SERIES: PBO-10C DESCRIPTION: AC-DC POWER SUPPLY  
date 11/12/2020 page 8 of 8  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
11/12/2020  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (ꢀ) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

PBO-10C-24

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-10C-3

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-10C-5

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-10C-9

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-15C

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-15C-12

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-15C-12-B

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-15C-15

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-15C-15-B

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-15C-24

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-15C-24-B

INTERNAL AC-DC POWER SUPPLY
CUI

PBO-15C-3

INTERNAL AC-DC POWER SUPPLY
CUI