PDRA-240 [CUI]

AC-DC POWER SUPPLY;
PDRA-240
型号: PDRA-240
厂家: CUI INC    CUI INC
描述:

AC-DC POWER SUPPLY

文件: 总6页 (文件大小:448K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
For more information, please visit the product page.  
date 10/17/2016  
page 1 of 6  
SERIES: PDRA-240 DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
•ꢀupꢀtoꢀ240ꢀWꢀcontinuousꢀpower  
•ꢀuniversalꢀinputꢀvoltageꢀrange  
•ꢀoverꢀcurrent,ꢀoverꢀvoltage,ꢀinputꢀunderꢀvoltage,ꢀshortꢀcircuit,ꢀ  
ꢀꢀꢀandꢀoverꢀtemperatureꢀprotections  
•ꢀactiveꢀpowerꢀfactorꢀcorrection  
•ꢀremoteꢀon/offꢀcontrol  
•ꢀoutputꢀtrim  
•ꢀlowꢀrippleꢀandꢀnoise  
•ꢀ-25ꢀtoꢀ+70°Cꢀtemperatureꢀrange  
•ꢀUL/cULꢀ60950-1ꢀsafetyꢀapproval  
•ꢀefficiencyꢀupꢀtoꢀ92%  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
efficiency2  
MODEL  
and noise1  
max  
typ  
(Vdc)  
24  
(A)  
(W)  
(mVp-p)  
(%)  
PDRA-240-24  
10  
240  
100  
92  
Notes:ꢀ  
1.ꢀAtꢀfullꢀload,ꢀnominalꢀinput,ꢀ20ꢀMHzꢀbandwidthꢀoscilloscope,ꢀwithꢀaꢀ1ꢀμFꢀceramicꢀandꢀ10ꢀμFꢀelectrolytyicꢀcapacitorꢀonꢀtheꢀoutput.  
2. At 230 Vac input.  
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ3.ꢀAllꢀspecificationsꢀareꢀmeasuredꢀatꢀTa=25°C,ꢀhumidityꢀ<75%,ꢀnominalꢀinputꢀvoltage,ꢀandꢀratedꢀoutputꢀloadꢀunlessꢀotherwiseꢀspecified.ꢀ  
PART NUMBER KEY  
PDRA-240 - XX  
BaseꢀNumber  
OutputꢀVoltage  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDRA-240 DESCRIPTION: AC-DC POWER SUPPLY  
date 10/17/2016 page 2 of 6  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
85  
120  
264  
370  
Vac  
Vdc  
voltage  
frequency  
47  
63  
Hz  
start-upꢀvoltageꢀatꢀfullꢀload  
shutdownꢀvoltageꢀatꢀfullꢀload  
75  
67  
83  
74  
Vac  
Vac  
underꢀvoltageꢀprotection  
atꢀ115ꢀVac  
at 230 Vac  
3.0  
1.5  
A
A
current  
atꢀ115ꢀVac  
at 230 Vac  
30  
60  
A
A
inrushꢀcurrent  
atꢀ115ꢀVac  
at 230 Vac  
0.98  
0.96  
powerꢀfactorꢀcorrection  
noꢀloadꢀpowerꢀconsumption  
1.0  
W
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
4,700  
±1  
units  
µF  
capacitiveꢀload  
initialꢀsetꢀpointꢀaccuracy  
lineꢀregulation  
%
at full load  
±0.5  
±1  
%
loadꢀregulation  
adjustability1  
fromꢀ5~100%ꢀload  
viaꢀbuiltꢀinꢀtrimꢀpot  
%
24  
28  
Vdc  
s
start-upꢀtime  
1.5  
hold-up time  
atꢀ115/230ꢀVac  
22  
100  
ms  
kHz  
%/°C  
switchingꢀfrequency  
temperatureꢀcoefficient  
±0.03  
Notes:ꢀ  
1.ꢀMaxꢀoutputꢀpowerꢀofꢀ240ꢀW.  
PROTECTIONS  
parameter  
conditions/description  
continuous,ꢀautoꢀrecovery  
autoꢀrecovery  
min  
typ  
max  
units  
overꢀvoltageꢀprotection  
overꢀcurrentꢀprotection  
shortꢀcircuitꢀprotection  
overꢀtemperatureꢀprotection  
110  
150  
%
continuous,ꢀautoꢀrecovery  
outputꢀshutdown,ꢀautoꢀrecovery  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
inputꢀtoꢀoutputꢀforꢀ1ꢀminute  
inputꢀtoꢀgroundꢀforꢀ1ꢀminute  
outputꢀtoꢀgroundꢀforꢀ1ꢀminute  
3,000  
1,500  
500  
Vac  
Vac  
Vac  
isolationꢀvoltage  
safetyꢀapprovals  
safetyꢀclass  
ULꢀ60950-1,ꢀENꢀ60950-1  
class I  
EMI/EMC  
ENꢀ55022,ꢀENꢀ55024,ꢀENꢀ61000-3-2,ꢀENꢀ61000-3-3  
CISPR22/EN55022,ꢀClassꢀBꢀ  
conducted emissions  
radiatedꢀemissions  
ESD  
CISPR22/EN55022,ꢀClassꢀB  
IEC/EN61000-4-2,ꢀClassꢀB,ꢀcontactꢀ±6ꢀkV/ꢀairꢀ±8ꢀkV  
IEC/EN61000-4-3,ꢀClassꢀA,ꢀ10ꢀV/m  
IEC/EN61000-4-4,ꢀClassꢀB,ꢀ±4ꢀkV  
radiatedꢀimmunity  
EFT/burst  
surge  
IEC/EN61000-4-5,ꢀClassꢀB,ꢀlineꢀtoꢀlineꢀ±2ꢀkV/ꢀlineꢀtoꢀgroundꢀ±4ꢀkV  
IEC/EN61000-4-6,ꢀClassꢀA,ꢀ10ꢀVr.m.s  
conductedꢀimmunity  
Notes:ꢀ  
2.ꢀTheꢀpowerꢀsupplyꢀisꢀconsideredꢀaꢀcomponentꢀwhichꢀwillꢀbeꢀinstalledꢀintoꢀfinalꢀequipment.ꢀꢀTheꢀfinalꢀequipmentꢀstillꢀmustꢀbeꢀtestedꢀtoꢀmeetꢀtheꢀnecessaryꢀEMCꢀdirectives.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDRA-240 DESCRIPTION: AC-DC POWER SUPPLY  
date 10/17/2016 page 3 of 6  
(
)
SAFETY & COMPLIANCE CONTINUED  
parameter  
conditions/description  
min  
typ  
max  
units  
PFM  
IEC/EN61000-4-8,ꢀClassꢀA,ꢀ10ꢀA/m  
IEC/EN61000-4-11,ꢀClassꢀB,ꢀ0%-70%  
asꢀperꢀMIL-HDBK-217Fꢀatꢀ25ꢀ°C  
2011/65/EU  
voltageꢀdipsꢀ&ꢀinterruptions  
MTBF  
RoHS  
300,000  
hours  
Notes:ꢀ  
1.ꢀTheꢀpowerꢀsupplyꢀisꢀconsideredꢀaꢀcomponentꢀwhichꢀwillꢀbeꢀinstalledꢀintoꢀfinalꢀequipment.ꢀꢀTheꢀfinalꢀequipmentꢀstillꢀmustꢀbeꢀtestedꢀtoꢀmeetꢀtheꢀnecessaryꢀEMCꢀdirectives.  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-25  
-25  
typ  
max  
70  
units  
°C  
operatingꢀtemperature  
storageꢀtemperature  
storageꢀhumidity  
seeꢀderatingꢀcurves  
85  
°C  
non-condensing  
95  
%
MECHANICAL  
parameter  
dimensions  
material  
conditions/description  
min  
typ  
max  
units  
60.00ꢀxꢀ125.00ꢀxꢀ120.00ꢀ(2.36ꢀxꢀ4.92ꢀxꢀ4.72ꢀinches)  
heatꢀresistantꢀplasticꢀ(UL94V-0)ꢀandꢀmetal  
mm  
weight  
820  
g
MECHANICAL DRAWING  
units: mm [inch]  
tolerance:ꢀ±1.00[±0.040]  
wireꢀrange:ꢀ26~10ꢀAWG  
stripꢀlength:ꢀ8.0ꢀmm  
mountsꢀtoꢀDINꢀRAILꢀTS35  
TERMINALꢀ  
CONNECTIONS  
TERMINAL  
Function  
+Vo  
1
2
3
4
5
6
7
+Vo  
-Vo  
-Vo  
AC(N)  
AC(L)  
CONTROLꢀTERMINAL  
TERMINAL  
Function  
+CTRL  
-CTRL  
1
2
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDRA-240 DESCRIPTION: AC-DC POWER SUPPLY  
date 10/17/2016 page 4 of 6  
DERATING CURVES  
loadꢀvs.ꢀambientꢀtemperature  
(atꢀ85~264ꢀVacꢀ/ꢀ120~370ꢀVdcꢀinputꢀvoltage)  
loadꢀvs.ꢀinputꢀvoltageꢀ  
(atꢀ25°C)  
100  
80  
100  
80  
Safe operating area  
Safe operating area  
60  
60  
40  
20  
40  
20  
-25  
0
50  
70  
85  
120  
100  
140  
264  
370  
Ambient Temperature (°C)  
Input Voltage (Vac/Vdc)  
EFFICIENCY CURVE  
PDRA-240-24ꢀEfficiencyꢀCurve  
(Efficiencyꢀvs.ꢀLoadꢀCurrent)  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDRA-240 DESCRIPTION: AC-DC POWER SUPPLY  
date 10/17/2016 page 5 of 6  
APPLICATION CIRCUIT  
Figure 1 Typical Application Circuit  
AC(L)  
AC(N)  
A C(L)  
+Vo  
RL  
-Vo  
A C(N )  
+Ctrl  
-Ctrl  
Figure 2 Remote Control Applications Circuit  
AC(L)  
AC (L)  
+Vo  
RL  
-Vo  
AC (N)  
AC(N)  
+C trl  
external voltage  
-Ctrl  
Theꢀpowerꢀsupplyꢀcanꢀbeꢀturnedꢀon/offꢀbyꢀusingꢀtheꢀ“CTRL”ꢀterminals.  
Enableꢀoutput:ꢀopen  
Disableꢀoutput:ꢀ4.5~12.5ꢀVdc  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PDRA-240 DESCRIPTION: AC-DC POWER SUPPLY  
date 10/17/2016 page 6 of 6  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initialꢀrelease  
10/17/2016  
Theꢀrevisionꢀhistoryꢀprovidedꢀisꢀforꢀinformationalꢀpurposesꢀonlyꢀandꢀisꢀbelievedꢀtoꢀbeꢀaccurate.  
Headquarters  
20050ꢀSWꢀ112thꢀAve.  
Tualatin,ꢀORꢀ97062  
800.275.4899  
Faxꢀ503.612.2383  
cui.com  
techsupport@cui.com  
CUIꢀoffersꢀaꢀtwoꢀ(2)ꢀyearꢀlimitedꢀwarranty.ꢀꢀCompleteꢀwarrantyꢀinformationꢀisꢀlistedꢀonꢀourꢀwebsite.  
CUIꢀreservesꢀtheꢀrightꢀtoꢀmakeꢀchangesꢀtoꢀtheꢀproductꢀatꢀanyꢀtimeꢀwithoutꢀnotice.ꢀꢀInformationꢀprovidedꢀbyꢀCUIꢀisꢀbelievedꢀtoꢀbeꢀaccurateꢀandꢀreliable.ꢀꢀHowever,ꢀnoꢀresponsibilityꢀisꢀ  
assumedꢀbyꢀCUIꢀforꢀitsꢀuse,ꢀnorꢀforꢀanyꢀinfringementsꢀofꢀpatentsꢀorꢀotherꢀrightsꢀofꢀthirdꢀpartiesꢀwhichꢀmayꢀresultꢀfromꢀitsꢀuse.  
CUIꢀproductsꢀareꢀnotꢀauthorizedꢀorꢀwarrantedꢀforꢀuseꢀasꢀcriticalꢀcomponentsꢀinꢀequipmentꢀthatꢀrequiresꢀanꢀextremelyꢀhighꢀlevelꢀofꢀreliability.ꢀꢀAꢀcriticalꢀcomponentꢀisꢀanyꢀcomponentꢀofꢀaꢀ  
lifeꢀsupportꢀdeviceꢀorꢀsystemꢀwhoseꢀfailureꢀtoꢀperformꢀcanꢀbeꢀreasonablyꢀexpectedꢀtoꢀcauseꢀtheꢀfailureꢀofꢀtheꢀlifeꢀsupportꢀdeviceꢀorꢀsystem,ꢀorꢀtoꢀaffectꢀitsꢀsafetyꢀorꢀeffectiveness.  

相关型号:

PDRA-240-24

AC-DC POWER SUPPLY
CUI

PDRB-300

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-300-24

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-300-48

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-45

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-45-12

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-45-24

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-45-48

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-75

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-75-12

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-75-24

AC-DC DIN RAIL POWER SUPPLY
CUI

PDRB-75-48

AC-DC DIN RAIL POWER SUPPLY
CUI