PDRC-75-12 [CUI]
AC-DC DIN RAIL POWER SUPPLY;型号: | PDRC-75-12 |
厂家: | CUI INC |
描述: | AC-DC DIN RAIL POWER SUPPLY |
文件: | 总6页 (文件大小:499K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
date 06/17/2019
page 1 of 6
SERIES: PDRC-75 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
FEATURES
• low profile for building automation
• universal input (90~264 Vac)
• integrated fuse and surge protection
• 3,000 Vac input/output isolation voltage
• DC On/Low LED indicators
• over-voltage/current protection
• UL/cUL, TUV, CE certified
output
voltage
output
current
max
output
power
max
ripple
efficiency2
MODEL
and noise1
max
typ
(Vdc)
5
(A)
(W)
(mVp-p)
(%)
PDRC-75-5
12.0
6.0
5.0
4.2
3.8
60
72
50
50
50
50
50
80
86
86
89
89
PDRC-75-12
PDRC-75-15
PDRC-75-24
PDRC-75-24-23
12
15
24
24
75
100
91
Notes:
1. At full load, nominal input, 20 MHz bandwidth oscilloscope.
2. At nominal input.
3. Model PDRC-75-24-2 is UL 1310 certified.
4. All specifications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
PDRC-75 - XX
Base Number
Output Voltage
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PDRC-75 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
date 06/17/2019 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
90
120
264
375
Vac
Vdc
voltage
frequency
47
63
Hz
at 90 Vac, full load
5 Vdc output model
12, 15 output model
24 Vdc output model
1.5
1.7
2.2
A
A
A
current
at 115 Vac, full load
at 230 Vac, full load
30
60
A
A
inrush current
leakage current
input to output
0.25
mA
OUTPUT
parameter
conditions/description
min
typ
max
3,500
±1
units
µF
capacitive load
initial set point accuracy
line regulation
load regulation
at Vi nom, full load
%
at full load, V in min to V in max
±1
%
at Vi nom, 0~100% load
±1
%
via built in trim pot, 0.8 A load
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
5
12
13.5
24
5.5
14
16.5
28
Vdc
Vdc
Vdc
Vdc
Vdc
adjustability
24 Vdc output model (PDRC-75-24-2)
20
24.2
5 Vdc output model (5.5 Vdc)
10.5
5.1
4.5
3.6
3.7
A
A
A
A
A
12 Vdc output model (14.0 Vdc)
15 Vdc output model (16.5 Vdc)
24 Vdc output model (28.0 Vdc)
24 Vdc output model (PDRC-75-24-2) (24.2 Vdc)
rated continuous loading at
max trim voltage
at Vi nom, full load
at Vi nom, full load with max capacitive load
1.0
1.5
s
s
start-up time
rise time
at Vi nom, full load
at Vi nom, full load with max capacitive load
150
500
ms
ms
5, 12 Vdc output models
at 115 Vac, full load
at 230 Vac, full load
16
60
ms
ms
hold-up time
15, 24 Vdc output models
at 115 Vac, full load
at 230 Vac, full load
12
60
ms
ms
fall time
at Vi nom, full load
150
2
ms
ms
transient recovery time
switching frequency
temperature coefficient
at Vi nom, 100~50% load
at Vi nom, full load
35
45
kHz
±0.03
%/°C
at Vi nom, full load, for 1 second
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
7.5
18
22
35
Vdc
Vdc
Vdc
Vdc
power back immunity
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
3.5
9.0
11.0
19.2
4.5
Vdc
Vdc
Vdc
Vdc
DC ON indicator threshold at
start-up (GREEN)
10.8
13.5
21.6
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
3.5
9.0
11.0
19.2
4.5
Vdc
Vdc
Vdc
Vdc
DC LOW indicator threshold
after start-up (RED)
10.8
13.5
21.6
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PDRC-75 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
date 06/17/2019 │ page 3 of 6
PROTECTIONS
parameter
conditions/description
min
typ
max
units
at Vi nom, full load, auto recovery
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
5.75
15
18
30
24.5
6.5
16.5
20
33
25.5
Vdc
Vdc
Vdc
Vdc
Vdc
over voltage protection
24 Vdc output model (PDRC-75-24-2)
fold forward (see curve)
24 Vdc output model (PDRC-75-24-2)
all other models
over current protection
102
110
108
150
%
%
short circuit protection
fold forward
SAFETY & COMPLIANCE
parameter
conditions/description
input to output for 1 minute
input to output at 500 Vdc
min
typ
max
units
3,000
4,242
Vac
Vdc
isolation voltage
isolation resistance
safety approvals5
safety class
100
MΩ
UL 508, UL 1310, UL 60950-1, EN 60950-1
ISA 12.12.01 (Class I, Div 2, Groups A~D)
class I
EN 55032 Class B, EN 55024, ENV 50204,
EN 61204-3, EN 61000-3-2, EN 61000-3-3,
EN 61000-6-2, EN 61000-6-3, EN 61000-4-2,
EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,
EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
EMI/EMC
pollution degree
2
degree of protection
IP20
as per Bellcore Issue 6 at 40 °C, GB
5 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
610,000
578,000
581,000
554,000
583,000
hours
hours
hours
hours
hours
MTBF
24 Vdc output model (PDRC-75-24-2)
RoHS
yes
Notes:
5. Model PDRC-75-24-2 is only model that is UL 1310 certified.
6. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.
ENVIRONMENTAL
parameter
conditions/description
min
-40
-40
20
typ
max
71
units
°C
operating temperature
storage temperature
humidity
see derating curves
85
°C
non-condensing
95
%
altitude
IEC 60068-2-13
4,850
m
meets IEC 60068-2-6 (Mounting on rail: 10~500
Hz, 2 G, along X,Y,Z axis, for 60 minutes on each
axis)
vibration
meets IEC 60068-2-27 (15 G, 11 ms, 3 axis, 6
faces, 3 times for each face)
shock
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PDRC-75 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
date 06/17/2019 │ page 4 of 6
MECHANICAL
parameter
dimensions
conditions/description
min
typ
max
units
91.00 x 90.00 x 57.00 (3.58 x 3.54 x 2.24 inches)
plastic
mm
material
weight
380
g
cooling
natural convection
input/output connector
accepts 24~12 AWG wire
MECHANICAL DRAWING
units: mm [inch]
tolerance:
X≤30.00: ±0.30 [±0.01]
30.00<X≤120.00: ±0.50 [±0.02]
unless otherwise noted
TERMINAL
CONNECTIONS
TERMINAL
Function
1
2
3
4
5
6
V-
V-
V+
V+
L
N
INSTALLATION
DIN RAIL
Cable
TS35/7.5 or TS35/15
flexible/solid, copper conductors
only, 60/75°C
24~12 AWG
Wire Range
(0.2~2.5 mm2)
Strip Length
Screw Torque
Position
7 mm
6 lb·in
Vertical
Natural convection, 25 mm
Cooling
clearance on all sides
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PDRC-75 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
date 06/17/2019 │ page 5 of 6
DERATING CURVES
Temperature Derating Curve
(Output Load vs. Ambient Tempearature)
100
5 Vdc output model
all other models
80
75
62.5
40
20
-40
0
20
30
40
56
61
80
71
Ambient Temperature (°C)
EFFICIENCY CURVES
PDRC-75-24 Efficiency Curve
(Efficiency vs. Load Current)
Load Current (%)
CURRENT LIMITED CURVE
PDRC-75-24 Typical Over Current Protection Curve
(Output Voltage vs. Time)
(%)
cui.com
Additional Resources: Product Page
CUI Inc │ SERIES: PDRC-75 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY
date 06/17/2019 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
06/17/2019
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
PDRV8243HDGQQ1
DRV8243-Q1 Automotive H-Bridge Driver with Integrated Current Sense and Diagnostics
TI
PDRV8243HRXYQ1
DRV8243-Q1 Automotive H-Bridge Driver with Integrated Current Sense and Diagnostics
TI
PDRV8243SDGQQ1
DRV8243-Q1 Automotive H-Bridge Driver with Integrated Current Sense and Diagnostics
TI
©2020 ICPDF网 联系我们和版权申明