SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
FEATURES
• 1 W isolated output
• smaller package
• single/dual unregulated outputs
• 3,000 Vdc isolation
• continuous short circuit protection
• extended temperature range (-40~105°C)
• antistatic protection up to 8kV
• high efficiency at light load
• efficiency up to 82%
input
voltage
output
voltage
output
current
output
power
max
ripple
efficiency
MODEL
and noise1
typ
range
min
max
typ
typ
(Vdc)
(Vdc)
(Vdc)
3.3
5
(mA)
(mA)
303
200
303
200
111
84
(W)
(mVp-p)
(%)
PES1-S3-S3-M
PES1-S3-S5-M
PES1-S5-S3-M
PES1-S5-S5-M
PES1-S5-S9-M
PES1-S5-S12-M
PES1-S5-S15-M
PES1-S5-S24-M
PES1-S5-D5-M
PES1-S5-D9-M
PES1-S5-D12-M
PES1-S5-D15-M
PES1-S5-D24-M
PES1-S12-S3-M
PES1-S12-S5-M
PES1-S12-S9-M
PES1-S12-S12-M
PES1-S12-S15-M
PES1-S12-D5-M
PES1-S12-D9-M
PES1-S12-D12-M
PES1-S12-D15-M
PES1-S12-D24-M
PES1-S15-S15-M
PES1-S24-S5-M
PES1-S24-S9-M
PES1-S24-S15-M
PES1-S24-S24-M
3.3
3.3
5
2.97~3.63
2.97~3.63
4.5~5.5
30
20
30
20
12
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
30
30
30
30
30
30
60
60
60
60
60
60
60
30
30
30
30
60
60
60
60
60
60
60
30
30
60
60
73
78
76
80
80
80
80
80
80
80
81
81
81
75
80
80
81
81
80
80
81
81
81
81
80
80
81
81
3.3
5
5
4.5~5.5
5
4.5~5.5
9
5
4.5~5.5
12
15
24
±5
±9
±12
±15
±24
3.3
5
5
4.5~5.5
7
67
5
4.5~5.5
4
42
5
4.5~5.5
±10
±6
±5
±3
±2
30
20
12
9
±100
±56
±42
±33
±21
303
200
111
84
5
4.5~5.5
5
4.5~5.5
5
4.5~5.5
5
4.5~5.5
12
12
12
12
12
12
12
12
12
12
15
24
24
24
24
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
13.5~16.5
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
9
12
15
±5
±9
±12
±15
±24
15
5
7
67
±10
±6
±5
±3
±2
7
±100
±56
±42
±33
±21
67
20
11
7
200
110
67
9
15
24
4
42
cui.com
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 2 of 8
input
voltage
output
voltage
output
current
output
power
max
ripple
efficiency
MODEL
(CONTINUED)
and noise1
typ
(Vdc)
range
min
(mA)
max
typ
(mVp-p)
typ
(%)
(Vdc)
(Vdc)
±5
(mA)
±100
±56
±42
±33
±21
(W)
PES1-S24-D5-M
PES1-S24-D9-M
PES1-S24-D12-M
PES1-S24-D15-M
PES1-S24-D24-M
24
24
24
24
24
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
±10
±6
±5
±3
±2
1
1
1
1
1
60
60
60
60
60
82
82
82
82
82
±9
±12
±15
±24
Notes:
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
PART NUMBER KEY
PES1 - SXX - XXX - M - X
Output Voltage
Output
S = single
D = dual
Base Number
Input Voltage
Packaging Style
"blank" = tube
TR = tape & reel
INPUT
parameter
conditions/description
min
typ
max
units
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
2.97
4.5
10.8
13.5
21.6
3.3
5
12
15
24
3.63
5.5
13.2
16.5
26.4
Vdc
Vdc
Vdc
Vdc
Vdc
operating input voltage
for maximum of 1 second
3.3 Vdc input models
5 Vdc input models
12 Vdc input models
15 Vdc input models
24 Vdc input models
-0.7
-0.7
-0.7
-0.7
-0.7
5
9
18
21
30
Vdc
Vdc
Vdc
Vdc
Vdc
surge voltage
filter
capacitance filter
OUTPUT
parameter
conditions/description
min
typ
max
units
for Vin change of 1%
3.3 Vdc output models
all other models
line regulation
±1.5
±1.2
%
%
measured from 10% load to full load
3.3 Vdc output models
5 Vdc output models
18
12
8
7
6
%
%
%
%
%
%
load regulation
9 Vdc output models
12 Vdc output models
15 Vdc output models
24 Vdc output models
5
voltage accuracy
see tolerance envelope curve
100% load, nominal input voltage
100% load
switching frequency
temperature coefficient
100
300
kHz
±0.03
%/°C
cui.com
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 3 of 8
PROTECTIONS
parameter
conditions/description
min
typ
typ
max
max
units
short circuit protection
continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter
conditions/description
min
units
Vdc
isolation voltage
isolation resistance
conducted emissions
radiated emissions
input to output for 1 minute at 1 mA max.
at 500 Vdc
3,000
1,000
MΩ
CISPR22/EN55022 class B (external circuit required, see Figure 1)
CISPR22/EN55022 class B (external circuit required, see Figure 1)
IEC/EN61000-4-2, class B, contact ± 8kV for single outputs
IEC/EN61000-4-2, class B, contact ± 6kV for dual outputs
ESD
MTBF
RoHS
as per MIL-HDBK-217F @ 25°C
2011/65/EU
3,500,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
-40
-55
typ
max
105
125
95
units
°C
operating temperature
storage temperature
storage humidity
see derating curve
°C
non-condensing
%
temperature rise
at full load, Ta = 25°C
25
°C
SOLDERABILITY
parameter
conditions/description
min
typ
max
300
245
units
°C
hand soldering
1.5 mm from case for 10 seconds
see reflow soldering profile
reflow soldering
°C
250
Peak.Temp 245ć(Max.)
245
217
200
60 Sec Max
(>217
)
ć
150
100
50
0
Time (sec.)
cui.com
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 4 of 8
MECHANICAL
parameter
dimensions
case material
weight
conditions/description
min
typ
max
units
single output models: 12.70 x 8.30 x 7.25
dual output models: 15.24 x 8.30 x 7.25
mm
mm
epoxy resin (UL94-V0)
single output models
dual output models
1.5
1.8
g
g
MECHANICAL DRAWING
SINGLE OUTPUT MODELS
12.70 0.20
[0.500 0.008]
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
0.60 0.10
[0.020 0.004]
PIN CONNECTIONS
A
PIN
1
Single Output
0.25 0.10
[0.010 0.004]
°
8
5
5
GND
Vin
0V
~
0
2
4
1
2
4
5
+Vo
NC
8
2.54
[0.100]
7.62
[0.300]
2.54 0.20
[0.100 0.08]
1.00 [0.039]
9.77 0.20
[0.385 0.079]
Top View
8
5
4
A
2
1
0.88 0.20
[0.035 0.008]
1.45 0.20
[0.057 0.008]
0.10
11.20 0.30
2.54
[0.100]
Grid Size:
2.54mm x 2.54mm
Front View
[0.441 0.012]
7.62
[0.300]
Side View
PCB Layout
Top View
cui.com
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 5 of 8
(
)
MECHANICAL DRAWING CONTINUED
DUAL OUTPUT MODELS
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
PIN CONNECTIONS
PIN
1
Dual Output
GND
Vin
0V
2
4
5
-Vo
+Vo
NC
7
10
Top View
Front View
Side View
Top View
PCB Layout
cui.com
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 6 of 8
DERATING CURVES
Tolerance Envelope Curve
Temperature Derating Curve
10
7.5
5
100
80
Ty
p
i
cal Load Line
2.5
2.5
0
Rated Output Voltage
-2.5
60
-2.5
Safe operating area
40
20
-5
-7.5
-7.5
-10
10
20
30
40
50
60
70
80
90
100
-40
-20
0
20
40
60
100105 120
Output Current Percentage (%)
(Nominal Input Voltage)
Ambient Temperature (°C)
EMC RECOMMENDED CIRCUIT
Figure 1
Table 1
Single Output Models
Recommended External Circuit Components
Vin
LDM
C0
LDM
(Vdc)
3.3
5
Vin
Vin
+Vo
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/50V
6.8μH
6.8μH
6.8μH
6.8μH
6.8μH
LOAD
C0
12
GND
GND
0V
15
24
Dual Output Models
LDM
Vin
Vin
+Vo
LOAD
C0
-Vo
GND
GND
TEST CONFIGURATION
Figure 2
Table 2
Oscilloscope
Lin
External components
Lin
4.7μH
Current
Probe
220μF, ESR < 1.0Ω
Load
Cin
Cin
DC
DC
at 100 KHz
Note: Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
cui.com
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 7 of 8
APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3. Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR(see Figure 3 & Table 3). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too
high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance
must be less than the maximum capacitive load (see Table 4).
Figure 3
Single Output
Dual Output
+Vo
0V
+Vo
0V
Vin
Vin
Cout
Cout
Cout
Cin
Cin
DC
DC DC
DC
GND
GND
-Vo
Table 3
Table 4
Vin
(Vdc)
Cin
Single Vo
Cout
(ꢀF)
Dual Vo
(Vdc)
Cout
(ꢀF)
Max. Capacitive Load1
Single Vout Max. Capacitive Load Dual Vout
(ꢀF)
4.7
4.7
--
(Vdc)
3.3
5
(μF)
(Vdc)
3.3
5
(μF)
220
220
220
220
220
220
(Vdc)
3.3
5
10
10
--
--
4.7
2.2
1
--
--
±5
5
100
100
100
100
100
--
9
4.7
2.2
1
±9
9
9
12
15
24
2.2
2.2
1
12
15
24
±12
±15
±24
12
15
24
12
15
24
1
0.47
0.47
Note: It’s not recommended to connect any external capacitors in
applications with less than 0.5 watt output.
Note:
1. For each output.
4. Output Voltage Regulation and Over-voltage Protection Circuit
The device for output voltage regulation, over-voltage and over-current protection is a linear regulator and a capacitor filtering net-
work with overheat protection, which can be connected to the input or output end in series (see Figure 4). The recommended capaci-
tance of its filter capacitor (see Table 4), and the linear regulator is based on the actual voltage and current required.
Single Output
+Vo
0V
REG
Vin
REG
DC DC
DC DC
GND
Figure 4
Dual Output
+Vo
0V
REG
REG
Vin
REG
GND
-Vo
Note:
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. Max. capacitive load tested at input voltage range and full load.
3. It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure.
4. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER
date 04/04/2014 │ page 8 of 8
REVISION HISTORY
rev.
description
date
1.0
initial release
03/19/2013
04/04/2014
1.01
added models, updated spec
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明