PSK-S20C-9-T [CUI]

AC-DC POWER SUPPLY;
PSK-S20C-9-T
型号: PSK-S20C-9-T
厂家: CUI INC    CUI INC
描述:

AC-DC POWER SUPPLY

文件: 总8页 (文件大小:1605K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Additional Resources: Product Page  
|
3D Model  
date 03/26/2021  
page 1 of 8  
SERIES: PSK-S20C DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• universal input (85~264 Vac)  
• -40~70°C operating range  
• over voltage/current protection  
• 4,000 Vac input/output isolation voltage  
• board/chassis/DIN-Rail configurations  
• CISPR32/EN55032 Class B  
• UL/EN/IEC 62368-1 certified  
output  
voltage  
output  
current  
output  
power  
max  
ripple  
efficiency2  
MODEL  
and noise1  
min  
max  
max  
typ  
(Vdc)  
3.3  
5
(A)  
(A)  
(W)  
(mVp-p)  
(%)  
PSK-S20C-3  
PSK-S20C-5  
PSK-S20C-9  
PSK-S20C-12  
PSK-S20C-15  
PSK-S20C-24  
0
3.60  
3.60  
2.20  
1.66  
1.33  
0.833  
11.8  
18  
120  
120  
120  
120  
120  
120  
74  
78  
79  
82  
83  
83  
0
9
0
20  
12  
15  
24  
0
20  
0
20  
0
20  
Notes:  
1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with 1 µF ceramic and 10 µF electrolytic capacitors on the output.  
2. At 230 Vac input.  
3. All specifications are measured at Ta=25°C, humidity <75%, nominal input voltage, and rated output load unless otherwise specified.  
PART NUMBER KEY  
PSK-S20C - XX - X  
Base Number  
Output Voltage  
Mounting Style:  
“blank” = board mount  
T = chassis mount  
DIN = DIN-rail mount  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PSK-S20C DESCRIPTION: AC-DC POWER SUPPLY  
date 03/26/2021 page 2 of 8  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
85  
100  
264  
370  
Vac  
Vdc  
voltage  
frequency  
current  
47  
63  
Hz  
at 115 Vac  
at 230 Vac  
440  
260  
mA  
mA  
at 115 Vac  
at 230 Vac  
12  
36  
A
A
inrush current  
no load power consumption  
0.5  
W
OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
3.3 Vdc output models  
5 Vdc output models  
9 Vdc output models  
12 Vdc output models  
15 Vdc output models  
24 Vdc output models  
10,000  
6,600  
4,400  
3,000  
2,000  
800  
µF  
µF  
µF  
µF  
µF  
µF  
capacitive load  
3.3 Vdc output models  
all other models  
±3  
±2  
%
%
initial set point accuracy  
line regulation  
load regulation  
at full load  
±0.5  
±1  
%
%
from 0~100% load  
at 115 Vac, full load  
at 230 Vac, full load  
5
44  
10  
55  
ms  
ms  
hold-up time  
switching frequency  
100  
kHz  
temperature coefficient  
±0.02  
%/°C  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
output voltage clamp  
3.3, 5 Vdc output models  
9 Vdc output models  
12, 15 Vdc output models  
24 Vdc output models  
7.5  
15  
20  
30  
Vdc  
Vdc  
Vdc  
Vdc  
over voltage protection  
over current protection  
auto recovery  
110  
%
short circuit protection  
hiccup, continuous, auto recovery  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
input to output for 1 minute, 5 mA  
UL 62368-1, EN 62368-1, IEC 62368-1  
Class II  
min  
typ  
max  
units  
isolation voltage  
safety approvals  
safety class  
4,000  
Vac  
conducted emissions  
radiated emissions  
ESD  
CISPR32/EN55032, Class B  
CISPR32/EN55032, Class B  
IEC/EN61000-4-2, contact ±6 kV/ air ±8 kV, Class B  
IEC/EN61000-4-3, 10 V/m, Class A  
radiated immunity  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PSK-S20C DESCRIPTION: AC-DC POWER SUPPLY  
date 03/26/2021 page 3 of 8  
(
)
SAFETY & COMPLIANCE CONTINUED  
parameter  
conditions/description  
min  
typ  
max  
units  
EFT/burst  
IEC/EN61000-4-4, ±4 kV, Class B  
IEC/EN61000-4-5, line to line ±2 kV, Class B  
surge  
IEC/EN61000-4-5, line to line ±4 kV/line to ground ±6 kV, Class B  
(external circuit required, see Figure 2)  
conducted immunity  
IEC/EN61000-4-6, 10 Vrms, Class A  
IEC/EN61000-4-11 Class B, 0%-70%  
voltage dips & interruptions  
MTBF  
RoHS  
as per MIL-HDBK-217F at 25°C  
300,000  
hours  
yes  
Notes:  
4. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-40  
-40  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
storage humidity  
see derating curves  
85  
°C  
non-condensing  
95  
%
SOLDERABILITY5  
parameter  
conditions/description  
for 3~5 seconds  
min  
350  
255  
typ  
360  
260  
max  
370  
265  
units  
°C  
hand soldering  
wave soldering  
for 5~10 seconds  
°C  
Notes:  
5. For board mount models only  
Peak Temp. 260°C Max.  
Wave Soldering Time  
4 Sec. Max.  
250  
200  
150  
100  
10 Sec. Max.  
50  
0
Time (sec.)  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PSK-S20C DESCRIPTION: AC-DC POWER SUPPLY  
date 03/26/2021 page 4 of 8  
DERATING CURVES  
EFFICIENCY CURVES  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PSK-S20C DESCRIPTION: AC-DC POWER SUPPLY  
date 03/26/2021 page 5 of 8  
MECHANICAL  
parameter  
conditions/description  
min  
typ  
max  
units  
board mount: 53.80 x 28.80 x 23.50 (2.118 x 1.134 x 0.925 inch)  
chassis mount: 76.00 x 31.50 x 32.30 (2.992 x 1.24 x 1.272 inch)  
DIN-Rail mount: 76.00 x 31.50 x 36.90 (2.992 x 1.24 x 1.453 inch)  
mm  
mm  
mm  
dimensions  
case material  
weight  
black flame-retardant and heat-resistant plastic (UL94V-0)  
board mount  
chassis mount  
DIN-Rail mount  
60  
80  
100  
g
g
g
(
)
MECHANICAL DRAWING BOARD MOUNT  
units: mm[inch]  
tolerance: ±0.50[±0.020]  
pin diameter tolerance: ±0.10[±0.004]  
PIN CONNECTIONS  
PIN  
1
Function  
AC (N)  
AC (L)  
-Vo  
2
3
4
+Vo  
Recommended PCB Layout  
Top View  
MECHANICAL DRAWING (CHASSIS MOUNT)  
units: mm[inch]  
tolerance: ±1.00[±0.039]  
wire range: 24~12 AWG  
tightening torque: max 0.4 N*m  
PIN CONNECTIONS  
PIN  
1
Function  
AC (N)  
AC (L)  
-Vo  
2
3
4
+Vo  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PSK-S20C DESCRIPTION: AC-DC POWER SUPPLY  
date 03/26/2021 page 6 of 8  
(
)
MECHANICAL DRAWING DIN-RAIL MOUNT  
units: mm [inch]  
tolerance: ±1.00[±0.039]  
installed on DIN Rail TS35  
wire range: 24~12 AWG  
tightening torque: max 0.4 N*m  
PIN CONNECTIONS  
PIN  
1
Function  
AC (N)  
AC (L)  
-Vo  
2
3
4
+Vo  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PSK-S20C DESCRIPTION: AC-DC POWER SUPPLY  
date 03/26/2021 page 7 of 8  
APPLICATION CIRCUIT  
Figure 1  
Table 1  
Table 2  
Recommended External Circuit Components  
C26  
Vo  
(Vdc)  
Vo  
FUSE  
MOV  
C1  
TVS  
C26  
(Vdc)  
3.3  
5
3.3  
5
3.15A/250V S20K300 1 μF/50 V 220 μF/16V SMBJ7.0A  
3.15A/250V S20K300 1 μF/50 V 220 μF/16V SMBJ7.0A  
3.15A/250V S20K300 1 μF/50 V 120 μF/25V SMBJ12A  
3.15A/250V S20K300 1 μF/50 V 120 μF/25V SMBJ20A  
3.15A/250V S20K300 1 μF/50 V 120 μF/25V SMBJ20A  
470 μF/16V (solid capacitor)  
470 μF/16V (solid capacitor)  
470 μF/16V (solid capacitor)  
390 μF/25V  
9
9
12  
15  
12  
15  
24  
390 μF/25V  
24  
3.15A/250V S20K300 1 μF/50 V  
68 μF/35V  
SMBJ30A  
220 μF/35V  
Notes:  
6. When output terminal is connected to a high frequency switch type load, use Table 2 for C2 values.  
EMC RECOMMENDED CIRCUIT  
Figure 2  
Table 3  
Recommended External Circuit Components  
FUSE  
MOV1  
6.3 A/250 V, slow fusing  
S20K300  
MOV2, MOV3  
GDT  
S10K300  
EM3600XS  
4.7 µH  
LDM  
LCM  
2 mH  
CX  
0.22 μF/275 Vac  
1 nF/400 Vac  
1 MΩ/ 2 W  
CY1, CY2  
R1  
Note:  
Also refer to Table 1.  
Notes:  
7. C1 is a ceramic capacitor used to filter high frequency noise.  
8. C2 is an electrolytic capacitor and it is recommended to be high frequency and low impedance. For capacitance and current of capacitor, refer to the datasheet provided by the  
manufacturer. Voltage derating of capacitor should be at least 80%.  
9. TVS is a recommended component to protect post-circuits (if converter fails).  
cui.com  
Additional Resources: Product Page  
|
3D Model  
CUI Inc SERIES: PSK-S20C DESCRIPTION: AC-DC POWER SUPPLY  
date 03/26/2021 page 8 of 8  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
03/07/2019  
12/22/2020  
03/26/2021  
1.01  
1.02  
company logo updated  
curves and circuit drawings updated  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY