VGS-100W-15 [CUI]
INTERNAL AC-DC POWER SUPPLY;型号: | VGS-100W-15 |
厂家: | CUI INC |
描述: | INTERNAL AC-DC POWER SUPPLY |
文件: | 总5页 (文件大小:1315K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
|
3D Model
date 06/04/2021
page 1 of 5
SERIES: VGS-100W │ DESCRIPTION: INTERNAL AC-DC POWER SUPPLY
FEATURES
• wide input range (85 ~ 305 VAC)
• available with conformal coating or terminal cover options
• UL/EN/IEC 62368 certified
• designed to meet IEC/EN 61558 and IEC/EN 60335 system requirements
• short-circuit, over-current, over-voltage protections
• CISPR/EN55032 Class B radiated/conducted emissions
output
voltage
output
current
max
output
power
max
ripple
efficiency²
MODEL
and noise1
typ
typ
(Vdc)
5
(A)
(W)
(mVp-p)
(%)
VGS-100W-5
VGS-100W-12
VGS-100W-15
VGS-100W-24
VGS-100W-36
VGS-100W-48
18.0
8.5
7.0
4.5
2.8
2.3
90
100
120
120
150
200
200
85.5
87.0
87.0
89.5
89.5
90.5
12
15
24
36
48
102
105
108
100
110
Notes:
1. Ripple & noiswe are measured at 20 MHz BW with 47 µF aluminum electrolytic capacitor and 0.1 µF ceramic capacitor on the output.
2. Measured at 230 Vac.
PART NUMBER KEY
VGS-100W-XX-X
Base Number
Output Voltage
A - with terminal cover
B - with conformal coating
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/04/2021 │ page 2 of 5
INPUT
parameter
conditions/description
min
typ
max
units
ac input
dc input
85
120
305
431
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 115 Vac
at 230 Vac
3
1.5
A
A
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
35
65
A
A
leakage current
at 277 Vac
0.75
mA
no load power consumption
at 230 Vac, 5 Vdc, 12 Vdc, 15 Vdc, 24 Vdc output
at 230 Vac, 36 Vdc, 48 Vdc output
0.3
0.5
W
W
OUTPUT
parameter
conditions/description
min
typ
max
units
5 Vdc output
12 Vdc output
15 Vdc output
24 Vdc output
36 Vdc output
48 Vdc output
10,000
6,800
3,300
2,200
1,000
470
μF
μF
μF
μF
μF
μF
capacitive load
line regulation
load regulation
hold-up time
rated load
±0.5
%
0% ~ 100%, 5 Vdc output
0% ~ 100%, other outputs
±1
±0.5
%
%
at 115 Vac
at 230 Vac
10
55
ms
ms
switching frequency
temperature coefficient
adjustability
65
kHz
%/°C
%
±0.03
±10
built in trim pot
5 Vdc output
other outputs
±2
±1
%
%
initial set point accuracy
PROTECTIONS
parameter
conditions/description
min
typ
max
units
5 Vdc output, clamp, auto recovery
12 Vdc output, clamp, auto recovery
15 Vdc output, clamp, auto recovery
24 Vdc output, clamp, auto recovery
36 Vdc output, clamp, auto recovery
48 Vdc output, clamp, auto recovery
7.5
19.2
24
38.4
57.6
60
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
over voltage protection
over current protection
short circuit protection
auto recovery
110
160
%
continuous, hiccup, auto recovery
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
input to ground, 1 min. <10mA
input to output, 1 min. <10mA
output to ground, 1 min. <10mA
2,000
4,000
1,250
Vac
Vac
Vac
isolation voltage
safety approvals
certified to
62368: IEC, EN, UL
designed to meet 60335: IEC, EN
designed to meet 61558: IEC, EN
safety class
EMI/EMC
class I
CISPR 32/EN 55032 Class B, IEC 61000-3-2 Class A
ESD
IEC/EN 61000-4-2 Contact ±6KV/Air ±8KV perf. criteria A
IEC/EN 61000-4-3 10 V/m perf. criteria A
radiated immunity
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/04/2021 │ page 3 of 5
SAFETY & COMPLIANCE
EFT/burst
IEC/EN 61000-4-4 ±2KV perf. criteria A
surge
IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV perf. criteria A
IEC/EN 61000-4-6 10 Vr.m.s perf. criteria A
conducted immunity
voltage dips and interruption
IEC/EN 61000-4-11 0%, 70% perf. criteria B
MTBF
RoHS
as per MIL-HDBK-217F at 25°C
yes
300,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
-30
-40
20
typ
max
70
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
85
°C
non-condensing
non-condensing
90
%
10
95
%
MECHANICAL
parameter
conditions/description
min
typ
max
units
dimensions
129.00 x 97.00 x 30.00 mm
mm
5 Vdc output
other outputs
325
305
g
g
weight
cooling
free air convection
case material
Metal (AL1100, SGCC)
MECHANICAL DRAWING
units: mm
tolerance: ±1 [±0.039]
PIN CONNECTIONS
PIN
1
Function
AC(L)
2
AC(N)
3
4
-Vo
-Vo
Screw
spec.
Torque
(max)
5
Position
2 - 4
7 - 8
L (max)
5 mm
6
+Vo
+Vo
M3
M3
0.4N·m
7
3 mm
0.4N·m
Note: At least one hole position, 1 ~ 9, must be
securely connected to Protective Earth (PE)
wire range: 22-12 AWG
connector tightening torque: M3.5, 0.8 N·m
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/04/2021 │ page 4 of 5
DERATING CURVE
EFFICIENCY CURVES
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VGS-100W │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/04/2021 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
09/02/2020
06/04/2021
1.01
derating and efficiency curves updated
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明