VGS-350B-48 [CUI]

AC-DC POWER SUPPLY;
VGS-350B-48
型号: VGS-350B-48
厂家: CUI INC    CUI INC
描述:

AC-DC POWER SUPPLY

文件: 总5页 (文件大小:554K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
For more information, please visit the product page.  
date 06/20/2018  
page 1 of 5  
SERIES: VGS-350B DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• built-in cooling with temperature-controlled fan  
• +70°C operation  
• output trim  
• current/voltage/temperature protections  
• screw terminal interface  
• switch-selectable AC input range  
• low standby power consumption  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
efficiency2  
MODEL  
and noise1  
max  
typ  
(Vdc)  
12  
(A)  
(W)  
(mVp-p)  
(%)  
VGS-350B-12  
VGS-350B-24  
VGS-350B-30  
VGS-350B-48  
29  
348  
350.4  
348  
150  
150  
200  
200  
85  
88  
88  
89  
24  
14.6  
11.6  
7.3  
30  
48  
350.4  
Notes:  
1. 20 MHz bandwidth oscilloscope, 12” of twisted load cables paralleled with 0.1 µF ceramic and 47 µF electrolytic capacitors placed across the terminals at the load.  
2. At 230 Vac, 50 Hz, full load.  
3. All specifications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specified.  
PART NUMBER KEY  
VGS-350B - XX  
Base Number  
Output Voltage  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: VGS-350B DESCRIPTION: AC-DC POWER SUPPLY  
date 06/20/2018 page 2 of 5  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
90  
180  
115  
230  
132  
264  
Vac  
Vac  
voltage  
via input selector switch1  
frequency  
current  
47  
63  
Hz  
at 115 Vac, full load  
at 230 Vac, full load  
6.5  
4
A
A
inrush current  
at 230 Vac, cold start, full load  
at 240 Vac  
60  
2
A
mA  
W
leakage current  
no load power consumption  
at 230 Vac  
0.75  
Notes:  
1. Input selector must be set to match input voltage or damage could occur.  
OUTPUT  
parameter  
line regulation  
conditions/description  
min  
typ  
max  
units  
±0.5  
%
12 Vdc output model  
all other models  
±1  
±0.5  
%
%
load regulation  
adjustability  
start-up time  
rise time  
built in trim pot  
±10  
%
s
at 115/230 Vac, full load  
at 115/230 Vac, full load  
1.5  
30  
ms  
at 115 Vac, full load  
at 230 Vac, full load  
12  
16  
ms  
ms  
hold-up time  
switching frequency  
65  
kHz  
PROTECTIONS  
parameter  
conditions/description  
min  
115  
105  
typ  
max  
150  
150  
units  
%
over voltage protection  
over current protection  
short circuit protection  
over temperture protection  
output shutdown, auto recovery  
output shutdown, auto recovery  
output shutdown, auto recovery  
output shutdown, auto recovery  
%
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
input to output for 1 minute, 10 mA  
input to ground for 1 minute, 10 mA  
output to ground for 1 minute, 10 mA  
1,500  
1,500  
500  
Vac  
Vac  
Vac  
isolation voltage  
input to output at 500 Vdc  
input to ground at 500 Vdc  
output to ground 500 Vdc  
100  
100  
100  
MΩ  
MΩ  
MΩ  
isolation resistance  
safety approvals  
IEC/EN 60950-1, UL 60950-1  
class I  
safety class  
conducted emissions  
radiated emissions  
voltage fluctuation and flicker  
ESD immunity  
EN 55032:2015, Class A  
EN 55032:2015, Class A  
EN 61000-3-3:2013, Class A  
IEC 61000-4-2, air: ±8 kV; contact: ±4 kV, Class A  
IEC 61000-4-3, 3 V/m, Class A  
radiated field immunity  
electrical fast transient  
immunity  
IEC 61000-4-4, Ac power port: 1 kV;  
signal & telecommunication ports: 0.5 kV, Class B  
Notes:  
2. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: VGS-350B DESCRIPTION: AC-DC POWER SUPPLY  
date 06/20/2018 page 3 of 5  
(
)
SAFETY & COMPLIANCE CONTINUED  
parameter  
conditions/description  
min  
typ  
max  
units  
IEC 61000-4-5, input L to input N: 1 kV;  
input L to FG: 2 kV; input N to FG: 2 kV, Class C  
surge immunity  
IEC 61000-4-6, frequency range: 0.15~80 MHz;  
field strength: 3 Vms, Class A  
conducted immunity  
magnetic field immunity  
IEC 61000-4-8, 1 A/m, Class A  
IEC 61000-4-11:  
voltage dips >95% reduction, 0.5 period, Class A  
voltage dips 30% reduction, 25 period, Class B  
voltage dips >95% reduction, 250 period, Class C  
voltage dips, interruptions  
MTBF  
as per MIL-HDBK-217F, 25°C  
200,000  
hours  
RoHS  
yes  
Notes:  
1. The power supply is considered a component which will be installed into final equipment. The final equipment still must be tested to meet the necessary EMC directives.  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-20  
-40  
20  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
operating humidity  
storage humidity  
see derating curves  
85  
°C  
non-condensing  
non-condensing  
90  
%
10  
95  
%
DERATING CURVES  
Output Load vs. Input Voltage  
(at 25°C, Natural Convection)  
Output Load vs. Ambient Temperature  
(Natural Convection)  
100  
80  
100  
80  
60  
60  
40  
40  
20  
0
20  
0
30  
40  
70  
20  
50  
-20  
0
10  
60  
105  
210  
115  
230  
100  
200  
90  
180  
95  
190  
132  
264  
Ambient Temperature (°C)  
Input (Vac)  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: VGS-350B DESCRIPTION: AC-DC POWER SUPPLY  
date 06/20/2018 page 4 of 5  
MECHANICAL  
parameter  
conditions/description  
min  
typ  
max  
units  
mm  
g
dimensions  
215 x 115 x 30  
weight  
1000  
cooling  
cooling fan  
input/output connector  
screw terminals accept 22~12 AWG wire, 1.2 N-m torque  
MECHANICAL DRAWING  
units: mm  
tolerance: ±0.3 mm  
I/P & O/P Connector  
Input/Output Connector  
ꢃꢅꢀfꢅ  
PIN  
1
Function  
AC(L)  
AC(N)  
FG  
Trim  
POT  
+V  
2
3
+V  
4
-V  
+V  
5
-V  
-V  
6
-V  
-V  
7
+V  
-V  
(FG)  
AC(N)  
AC(L)  
8
9
+V  
+V  
MOUNTING SCREWS  
Screw Size Max Depth  
Torque  
M3X0.5  
M4X0.7  
4 mm  
4 mm  
<0.75 N-m  
<0.8 N-m  
MOUNTING ORIENTATION  
ꢃꢈ0ꢇ  
ꢅꢀꢂ  
Input Selector Switch  
ꢄꢊꢊꢀfꢂꢁꢀ  
ꢀꢅꢁꢅfꢂꢁꢀ  
ꢄꢃꢁꢀfꢂꢁꢀ  
ꢅꢀꢂ  
Note:  
1. Parts should not be mounted in an  
upside down orientation.  
ꢅꢅꢃꢁꢆ  
ꢉꢈ0ꢇ  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: VGS-350B DESCRIPTION: AC-DC POWER SUPPLY  
date 06/20/2018 page 5 of 5  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
06/20/2018  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

VGS-350C

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-350C-12

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-350C-15

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-350C-24

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-350C-36

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-350C-48

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-350C-5

INTERNAL AC-DC POWER SUPPLY
CUI

VGS-35B

AC-DC POWER SUPPLY
CUI

VGS-35B-12

AC-DC POWER SUPPLY
CUI

VGS-35B-24

AC-DC POWER SUPPLY
CUI

VGS-35B-48

AC-DC POWER SUPPLY
CUI

VGS-50

SWITCHING POWER SUPPLY
CUI