VMS-100C-15 [CUI]
AC-DC POWER SUPPLY;型号: | VMS-100C-15 |
厂家: | CUI INC |
描述: | AC-DC POWER SUPPLY |
文件: | 总7页 (文件大小:1647K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
|
3D Model
date 06/15/2021
page 1 of 7
SERIES: VMS-100C │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• universal input voltage (85 ~ 264 Vac)
• wide operating temperature (-40 to +85C)
• active power factor correction
• certified to 60601, 60335, and 61558 safety standards
• suitable for safety class I or class II installations
• over voltage, over current, over temperature, and short circuit protections
• adjustable output via trim POT
• low leakage current (< 0.1 mA)
• low standby power consumption (0.5 W)
output
voltage
output
current
output
power
transient2
output
power
ripple
efficiency4
MODEL
and noise3
range1
(Vdc)
max
(A)
max
(W)
max
(W)
max
(mVp-p)
typ
(%)
(Vdc)
12
VMS-100C-12
VMS-100C-15
VMS-100C-24
VMS-100C-27
VMS-100C-36
VMS-100C-48
11.4~12.6
14.3~15.8
22.8~25.2
25.6~28.4
35.28~37.8
45.6~50.4
8.33
6.66
4.16
3.70
2.78
2.08
100
100
100
100
100
100
125
125
125
125
125
125
120
120
150
150
200
200
94.0
94.0
95.0
95.0
94.0
94.5
15
24
27
36
48
Notes:
1. When the output voltage is increased, the total output power cannot exceed the nominal output power.
2. If the total output power exceeds the nominal output power, it can be maintained for a maximum of 10 seconds, but not repeated for at least 30 minutes. The power
supply cannot exceed the transient power.
3. At full load, nominal input, 20 MHz bandwidth oscilloscope, tip & barrel method, output terminated with 47 µF electrolytic and 0.1 µF ceramic capacitors.
Under light load conditions (<15%) the measurement may double in an effort to maximize converter efficiency.
4. At 230 Vac.
PART NUMBER KEY
VMS-100C - XX - XXX
Chassis:
“blank” = open-frame
CNF = covered
Base Number
Output Voltage
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VMS-100C │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/15/2021 │ page 2 of 7
INPUT
parameter
conditions/description
min
typ
max
units
ac input
dc input
85
120
264
370
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 115 Vac
at 230 Vac
2.0
1.0
A
A
at 115 Vac, cold start
at 230 Vac, cold start
40
75
A
A
inrush current
leakage current
at 240 Vac
0.1
mA
at 115 Vac, full load
at 230 Vac, full load
0.98
0.94
power factor correction
no load power consumption
0.5
W
OUTPUT
parameter
conditions/description
min
typ
max
units
12 Vdc output model
15 Vdc output model
24 Vdc output model
27 Vdc output model
36 Vdc output model
48 Vdc output model
6,000
5,000
3,200
2,400
2,000
1,600
μF
μF
μF
μF
μF
μF
output capacitance
at full load, 25°C
12 & 15 Vdc output models
24, 27, 36 & 48 Vdc output models
initial set point accuracy
±2
±1
%
%
line regulation
load regulation
hold-up time
rated load
±0.5
±1
%
%
0 ~ 100% load
at 230 Vac, 25°C
15
ms
temperature coefficient
adjustability
±0.03
±5
%/°C
%
via built-in trimpot
PROTECTIONS
parameter
conditions/description
min
typ
max
units
output shutdown, latching
12 Vdc output model
15 Vdc output model
24 Vdc output model
27 Vdc output model
36 Vdc output model
48 Vdc output model
16
25
32
35
50
60
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
over voltage protection
over current protection
short circuit protection
over temperature protection
hiccup, auto recovery
130
%
continuous, auto recovery, hiccup
output shutdown, auto recovery
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VMS-100C │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/15/2021 │ page 3 of 7
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
input to ground for 1 minute; <10 mA
input to output for 1 minute; <10 mA
output to ground for 1 minute; <10 mA
1,500
4,000
1,500
Vac
Vac
Vac
isolation voltage
safety approvals
certified to 60601: ES, EN
certified to 60335: EN
certified to 61558: EN
safety class
class I (with PE), class II (without PE)
CISPR32/EN55032 CLASS B
conducted emissionsꢀ
radiated emissionsꢀ
harmonic current
ESD
CISPR32/EN55032 (Class B for safety class I installations; Class A for safety class II installations)
IEC/EN61000-3-2 CLASS A
IEC/EN 61000-4-2 Contact ±8KV/Air ±15KV perf. Criteria A
IEC/EN 61000-4-3 10V/m perf. Criteria A
radiated immunity
EFT/burst
IEC/EN 61000-4-4 ±2KV perf. Criteria A
surge
IEC/EN 61000-4-5 line to line ±2KV/line to ground ±4KV perf. Criteria A
IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A
conducted immunity
voltage dips and interruptions
MTBF
IEC/EN61000-4-11 0%, 70% perf. Criteria B
as per MIL-HDBK-217F at 25°C
300,000
hours
RoHS
yes
Notes:
1. The power supply is considered a component of the end system. All EMC performance has been tested on a metal plate with the dimensions 360 x 360 x 1 mm.
The power supply must be integrated into the end system for proper electromagnetic compatibility testing.
ENVIRONMENTAL
parameter
conditions/description
min
-40
-40
20
typ
max
85
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
see derating curves
85
°C
non-condensing
non-condensing
90
%
10
95
%
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VMS-100C │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/15/2021 │ page 4 of 7
DERATING CURVES
Note: With an AC input voltage between 85 ~ 115 and a DC input between 120 ~ 160 Vdc the output power must be derated as per the temperature derating curve.
EFFICIENCY CURVES
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VMS-100C │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/15/2021 │ page 5 of 7
MECHANICAL
parameter
conditions/description
min
typ
max
units
open frame models: 76.20 x 50.80 x 31.00 [3.0 x 2.0 x 1.381 inch]
covered models: 80.0 × 62.0 × 40.0 [3.149 x 2.440 x 1.574 inch]
mm
mm
dimensions
open frame models
covered models
125
180
g
g
weight
cooling
natural convection (no integrated fan)
MECHANICAL DRAWING
Open-frame
units: mm [inch]
general tolerance: ±1.00 [±0.039]
PIN-OUT
PIN Function
1
2
AC (N)
NC
3
AC (L)
-Vo
4, 5
6, 7
+Vo
CONNECTORS
Product Connector
Customer Connector
JST B3P-VH
or equivalent
Housing: JST VHR
Contact: JST SVH-21T-P1.1 or equivalent
AC CONNECTORS
DC CONNECTORS
JST B4P-VH
or equivalent
Housing: JST VHR
Contact: JST SVH-21T-P1.1 or equivalent
MOUNTING SCREWS
L
Position
1 ~ 4
Screw Spec.
Torque
(recommended)
M3
6mm
0.4 N·m
Note: 1. Class I system 1, 4 positions must be connected to the protective earth ground (
2. Class II system 1, 4 positions must be connected together.
3. It is recommended that a minimum distance of 10mm be placed between the PCB
edge and all other components.
).
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VMS-100C │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/15/2021 │ page 6 of 7
MECHANICAL DRAWING (CONTINUED)
Covered
units: mm [inch]
general tolerance: ±1.00 [±0.039]
PIN-OUT
PIN Function
1
2
AC (N)
NC
3
AC (L)
-Vo
4, 5
6, 7
+Vo
CONNECTORS
Product Connector
Customer Connector
Housing: JST VHR
JST B3P-VH
AC CONNECTORS
DC CONNECTORS
or equivalent
Contact: JST SVH-21T-P1.1 or equivalent
JST B4P-VH
or equivalent
Housing: JST VHR
Contact: JST SVH-21T-P1.1 or equivalent
MOUNTING SCREWS
L
Position
Screw Spec.
Torque
(recommended)
1 ~ 2
3 ~ 4
M3
M3
4mm
0.4 N·m
0.4 N·m
3mm
Note: 1. Safety Class I integrations require the metal case to be securely fastened to protective
earth ground ( ).
cui.com
Additional Resources: Product Page
|
3D Model
CUI Inc │ SERIES: VMS-100C │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/15/2021 │ page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
OVP updated
06/08/2021
06/15/2021
1.01
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
VMS-100C-24
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-100C-27
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-100C-36
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-100C-48
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-100C-CNF
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-120C
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-120C-12
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-120C-15
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-120C-24
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-120C-27
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-120C-36
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
VMS-120C-48
AC-DC POWER SUPPLYWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
CUI
©2020 ICPDF网 联系我们和版权申明