SERIES: VSK-S5 DESCRIPTION: AC-DC POWER SUPPLY  
FEATURES  
• up to 5.5 W continuous output  
• compact board mount design  
• universal input (85~264 Vac/110~370 Vdc)  
• single regulated output from 3.3~24 V  
• over voltage, over temperature, and short circuit protections  
• UL/cUL safety approvals  
• efficiency up to 78%  
RoHS  
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
and noise  
efciency  
MODEL  
typ  
max  
(Vdc)  
3.3  
5
(mA)  
(W)  
(mVp-p)  
(%)  
VSK-S5-3R3UA  
VSK-S5-5UA  
VSK-S5-9UA  
VSK-S5-12UA  
VSK-S5-15UA  
VSK-S5-24UA  
1250  
1000  
550  
4.125  
30  
30  
30  
30  
30  
30  
66  
72  
74  
76  
76  
78  
5
5
9
12  
15  
24  
420  
5
333  
5
230  
5.5  
PART NUMBER KEY  
VSK-S5 - XXUA  
Base Number  
Output Voltage  
cui.com  
CUI Inc SERIES: VSK-S5DESCRIPTION: AC-DC POWER SUPPLY  
date 08/23/2013 page 2 of 6  
INPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
85  
110  
264  
370  
Vac  
Vdc  
voltage  
frequency  
current  
47  
63  
Hz  
at 110 Vac  
at 230 Vac  
110  
70  
mA  
mA  
at 110 Vac  
at 230 Vac  
10  
20  
A
A
inrush current  
input fuse  
recommended external 1 A/250 V, slow-blow type  
temperature coefcient  
0.02  
%/°C  
OUTPUT  
parameter  
conditions/description  
min  
typ  
±0.5  
±1  
max  
units  
%
line regulation  
load regulation  
at 10~100% load  
%
3.3 V model  
all other models  
±3  
±2  
%
%
voltage set accuracy  
hold-up time  
at 230 Vac  
50  
ms  
kHz  
mA  
switching frequency  
leakage current  
100  
0.3  
max  
150  
PROTECTIONS  
parameter  
conditions/description  
diode clamp  
min  
typ  
typ  
units  
over voltage protection  
short circuit protection  
over temperature protection  
shutdown and auto restart  
°C  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
for 1 minute  
min  
max  
units  
isolation voltage  
safety approvals  
safety class  
4,000  
Vac  
IEC60950, EN60950, UL60950  
Class II  
conducted emissions  
radiated emissions  
ESD  
CISPR11/EN55011 Class A, Class B (external circuit required, see gure 2)  
CISPR11/EN55011 Class A, Class B (external circuit required, see gure 2)  
IEC/EN61000-4-2 Class B, contact ±6 kV / air ±8 kV  
IEC/EN61000-4-3 Class A, 10V/m  
radiated immunity  
IEC/EN61000-4-4 Class B, ±2 kV  
EFT/burst  
surge  
IEC/EN61000-4-4 Class B, ±4 kV (external circuit required, see gure 2)  
IEC/EN61000-4-5 Class B, ±1 kV / ±2 kV  
IEC/EN61000-4-5 Class B, ±2 kV / ±4 kV (external circuit required, see gure 2)  
IEC/EN61000-4-6 Class A, 10 Vr.m.s  
conducted immunity  
PFM  
IEC/EN61000-4-8 Class A, 10 A/m  
voltage dips & interruptions  
MTBF  
IEC/EN61000-4-11 Class B, 0%-70%  
at 25°C, max. load  
yes  
300,000  
hours  
RoHS compliant  
cui.com  
CUI Inc SERIES: VSK-S5DESCRIPTION: AC-DC POWER SUPPLY  
date 08/23/2013 page 3 of 6  
ENVIRONMENTAL  
parameter  
conditions/description  
min  
-25  
-40  
typ  
max  
70  
units  
°C  
operating temperature  
storage temperature  
case temperature  
humidity  
see derating curves  
105  
95  
°C  
°C  
non-condensing  
95  
%
DERATING CURVES  
load vs. ambient temperature  
load vs. input voltage (Vac)  
load vs. input voltage (Vdc)  
100  
100  
80  
100  
80  
80  
70  
60  
50  
40  
60  
50  
40  
60  
50  
40  
Safe operating area  
Safe operating area  
Safe operating area  
20  
20  
20  
-25  
-15 -10 -5  
0
5
15  
25  
45  
55  
65 70 75  
85  
95  
105 110 115  
125  
235 240 245  
255  
264  
80  
100  
120  
140  
290  
310  
330 340 350  
370  
Ambient Temperature (°C)  
Input Voltage (Vac)  
Input Voltage (Vdc)  
EFFICIENCY CURVES  
90  
85  
80  
75  
70  
65  
60  
55  
50  
VSK-S5-5UA @ 115 Vac  
VSK-S5-5UA @ 230 Vac  
VSK-S5-12UA @ 115 Vac  
VSK-S5-12UA @ 230 Vac  
VSK-S5-24UA @ 115 Vac  
VSK-S5-24UA @ 230 Vac  
10 20 30 40 50 60 70 80 90 100  
Load (%)  
cui.com  
CUI Inc SERIES: VSK-S5DESCRIPTION: AC-DC POWER SUPPLY  
date 08/23/2013 page 4 of 6  
MECHANICAL  
parameter  
dimensions  
material  
conditions/description  
50.8 x 25.4 x 15.16 (2.00 x 1.00 x 0.597 inch)  
UL94V-0  
min  
typ  
max  
units  
mm  
weight  
35  
g
MECHANICAL DRAWING  
units: mm [inch]  
tolerance: ±0.50 [±0.020]  
pin section tolerance: ±0.10 [±0.004]  
Grid Size: 2.54 x 2.54mm  
1.50 [0.059]  
2
1
3
4
Front View  
1.00[0.039]  
Top View  
PCB LAYOUT  
1
PIN CONNECTIONS  
4
3
PIN  
1
FUNCTION  
AC(L)  
AC(N)  
+Vo  
2
2
3
4
-Vo  
45.72 [1.800]  
50.80 [2.000]  
Bottom View  
cui.com  
CUI Inc SERIES: VSK-S5DESCRIPTION: AC-DC POWER SUPPLY  
date 08/23/2013 page 5 of 6  
TYPICAL APPLICATION CIRCUIT  
Table 1  
FUSE NTC  
C1  
C2  
Recommended External Circuit  
Components  
L
L
+Vo  
MODEL  
C11  
C21  
FUSE  
NTC  
(μF)  
(μF)  
+
RL  
VSK-S5-3R3UA  
VSK-S5-5UA  
VSK-S5-9UA  
VSK-S5-12UA  
VSK-S5-15UA  
VSK-S5-24UA  
1
1
1
1
1
1
47  
47  
33  
33  
33  
10  
1 A/250 V  
1 A/250 V  
1 A/250 V  
1 A/250 V  
1 A/250 V  
1 A/250 V  
5D-9  
5D-9  
5D-9  
5D-9  
5D-9  
5D-9  
Figure 1  
MOV  
-Vo  
N
N
Note:  
1. Output ltering capacitor C1 is a ceramic capacitor that is used to lter high frequency noise. C2 is an electrolytic capacitor. It is recommended to use high frequency and  
low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to the manufacturer’s datasheet. Voltage derating of capacitor should be 80%  
or above.  
EMC RECOMMENDED CIRCUIT  
Table 2  
Recommended External Circuit Components  
FUSE  
R2  
L
L
FUSE  
MOV  
R1, R2  
R3  
1 A/250 V  
561KD14  
CY1  
CY2  
CY3  
CY4  
R3  
MOV  
R1  
LCM CX  
2Ω/3W winding resistor  
1MΩ/2W  
Figure 2  
OUTPUT  
ACDC  
CY1, CY2,  
CY3, CY4  
N
N
1000pF/400Vac  
CX  
LCM  
CY  
0.22μF/275Vac  
10mH-30mH  
Y capacitor, 102K/400V  
TEST CONFIGURATION  
Connect Oscillograph Probe  
Copper sheet  
Table 3  
Capacitors  
FUSE  
L
+Vo  
C1  
C2  
1μF ceramic capacitor  
10μF electrolytic capacitor  
C1  
C2  
Figure 3  
Load  
N
-Vo  
12.7mm  
25.4mm  
25.4mm  
Note:  
1. All specications measured at Ta=25°C, humidity <75%, 220 Vac input voltage, and rated output load, unless otherwise specied.  
cui.com  
CUI Inc SERIES: VSK-S5DESCRIPTION: AC-DC POWER SUPPLY  
date 08/23/2013 page 6 of 6  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
new template applied  
V-Innity branding removed  
added efciency curves  
updated spec  
07/26/2011  
03/06/2012  
08/21/2012  
12/10/2012  
04/01/2013  
08/23/2013  
1.01  
1.02  
1.03  
1.04  
1.05  
updated spec  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical  
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to  
affect its safety or effectiveness.  

相关型号:

VSK-S5-5UA-T

AC-DC POWER SUPPLY
CUI

VSK-S5-9UA

AC-DC POWER SUPPLY
CUI

VSK-S5-9UA-T

AC-DC POWER SUPPLY
CUI

VSK-S5-T

AC-DC POWER SUPPLY
CUI

VSK-S5_15

AC-DC POWER SUPPLY
CUI

VSK-T15-HU

AC-DC POWER SUPPLY
CUI

VSK-T15-IU

AC-DC POWER SUPPLY
CUI

VSK-T15-JU

AC-DC POWER SUPPLY
CUI

VSK-T15-KU

AC-DC POWER SUPPLY
CUI

VSK.250

Standard Recovery Diodes, 250 A to 320 A (MAGN-A-PAK Power Modules)
VISHAY

VSK.320

Standard Recovery Diodes, 250 A to 320 A (MAGN-A-PAK Power Modules)
VISHAY

VSK1020

Rectifier Diode, Schottky, 1 Phase, 1 Element, 10A, 20V V(RRM), Silicon, TO-220, 2 PIN
MICROSEMI