VSUU-120D-305-P [CUI]
AC-TO-DC SUPPLY,AC-TO-DC CONVERTER,SWITCHING,OPEN FRAME;型号: | VSUU-120D-305-P |
厂家: | CUI INC |
描述: | AC-TO-DC SUPPLY,AC-TO-DC CONVERTER,SWITCHING,OPEN FRAME 开关 |
文件: | 总4页 (文件大小:207K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page.
date 08/16/2012
page 1 of 4
SERIES: VSUU-120-D │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• up to 120 W continuous power
• industry standard 3” x 5” footprint
• universal input (90-260 Vac / 130-370 Vdc)
• dual output
• active power correction
• internal EMI filter
• no minimum load required
• UL/cUL and TUV safety approvals
• class I
• efficiency 80%
• input surge current, over voltage, over load, and over current protections
RoHS
output
voltage
output
current
max
(A)
output
power
max
(W)
ripple and
noise
max
(mVp-p)
efficiency
MODEL
typ
(%)
(Vdc)
Vo1
Vo2
3.3
5
15
6
79.5
79.5
66
50
80
80
VSUU-120-D305
VSUU-120-D312
VSUU-120-D512
VSUU-120-D515
VSUU-120-D524A
VSUU-120-D524B
VSUU-120-D285
Vo1
Vo2
3.3
12
15
6
120
120
66
120
80
80
Vo1
Vo2
5
12
15
6
120
120
50
120
80
80
Vo1
Vo2
5
15
15
6
120
120
50
150
80
80
Vo1
Vo2
5
24
15
3.5
120
120
50
240
80
80
Vo1
Vo2
5
-24
15
2
120
120
50
-240
80
80
Vo1
Vo2
28
5
3.92
2
120
120
280
50
80
80
PART NUMBER KEY
VSUU-120 -DXXX - X
Base Number
Output Voltage
Power Fail Detect
“Blank” = No
P = Yes
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUU-120-D │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/16/2012 │ page 2 of 4
INPUT
parameter
conditions/description
min
typ
max
units
90
130
260
370
Vac
Vdc
voltage
frequency
current
47
63
Hz
at 115 Vac, full load
at 230 Vac, full load
1.7
1.0
A
A
at 115 Vac, 25°C, full load, cold start
at 230 Vac, 25°C, full load, cold start
12
26
15
30
A
A
inrush current
power factor
full load at 90 ~ 260 Vac
0.95
0.97
1.0
OUTPUT
parameter
conditions/description
full load
min
typ
0.5
max
units
%
line regulation
load regulation
temperature coefficient
transient response
start-up
1
5
at 230 Vac
3
%
all output
± 0.04
%/°C
ms
s
full load to half load at 100 Vac
full load at 100 Vac
full load at 110 Vac
4
2
0.3
16
1
hold-up
ms
PROTECTIONS
parameter
conditions/description
min
112
110
typ
max
132
150
units
%
over voltage protection
over current protection
%
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
primary to secondary
primary to earth ground
4,242
2,121
Vdc
Vdc
isolation voltage
isolation resistance
safety approvals
EMI/EMC
test voltage of 500 Vdc
50
MΩ
UL 60950-1 2nd edition, EN 60950-1 2nd edition
CISPR 22 class B, FCC part-15 class B
full load at 240 Vac
leakage current
RoHS compliant
0.4
0.75
mA
yes
ENVIRONMENTAL
parameter
conditions/description
min
0
typ
max
70
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
-40
5
85
°C
non-condensing
95
%
5
95
%
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUU-120-D │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/16/2012 │ page 3 of 4
DERATING CURVES
output power vs. ambient temperature
100
80
60
50
40
20
-25
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
MECHANICAL DRAWING
units: mm[inches]
tolerance: ±0.5mm
30.0 1.181
(2 PLCS)
39.2 1.543
13.5 0.531
81.4 3.205
G
N
L
P1
114.3 4.500
101.6 4.000
127.0 5.000
114.3 4.500
68.6 2.701
(2 PLCS)
14.0 0.551
65.3 2.571
P2
13
1
30.0 1.181
(3 PLCS)
16.80 0.661
6.4 0.252
(2 PLCS)
8.0 0.315
note:
1. Weight: 330~380 g (approx.)
2. Input connector mates with Molex housing 09-50-3051 and Molex 2478 or 2578 series crimp terminal.
3. Output connector mates with Molex housing 09-50-3131 and Molex 2478 or 2578 series crimp terminal.
CN2
Model No.
1
2
3
4
5
6
7
8
9
10
V2
V2
n/c
11
12
13
VSUU-120-D524B
VSUU-120-D285
VSUU-120-DXXX
n/c
n/c
V2
n/c
n/c
V2
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
com com com
com com com
com com com
com com n/c
com com n/c
com com n/c
*pin 13 for optional
power fail detect
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VSUU-120-D │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/16/2012 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
11/19/2010
12/19/2011
08/16/2012
1.01
1.02
new template applied
V-Infinity branding removed
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明