CY7C65221  
Dual I2C Slave Bridge  
Dual I2  
C Slave Bridge  
RoHS compliant package  
Features  
24-pin QFN (4 mm × 4 mm, 0.5 mm pitch, 0.55 mm height)  
Ordering part number CY7C65221-24LTXI  
Dual channel I2C slaves  
400 kHz I2C clock rate  
1 byte sub-addressing  
256 byte register space  
Applications  
Configurable slave port base address  
Interrupt line only for I2C_B (INT_B)  
Test and measurement systems  
Industrial  
Clocking: Integrated 48 MHz clock oscillator  
Operating voltage: 1.71 to 5.5 V  
Functional Description  
Operating temperature: –40 °C to 85 °C  
ESD protection: 2.2 kV HBM  
CY7C65221 is an I2C bus bridge. It functions as an I2C slave for  
two masters, allowing them exchange data. This bridge is to  
have a communication path between the Cypress FX3S RAID  
solution and the Dell board controller.  
Block Diagram  
VDDD  
VCCD  
Voltage  
Regulator  
RESET  
nXRES  
Controller  
Serial  
Communication  
Block  
Serial  
Communication  
Block  
8 bytes  
TX  
FIFO  
8 bytes  
TX  
FIFO  
I2C_SCL_A  
I2C_SDA_A  
I2C_SCL_B  
I2C_SDA_B  
INT_B#  
B_ADDR0  
B_ADDR1  
I2C  
Slave  
PORT A  
I2C  
Slave  
PORT B  
A_ADDR0  
A_ADDR1  
8 bytes  
RX  
FIFO  
8 bytes  
RX  
FIFO  
256 byte Register  
Space  
nFS  
GPIO  
Cypress Semiconductor Corporation  
Document Number: 001-89547 Rev. *C  
198 Champion Court  
San Jose, CA 95134-1709  
408-943-2600  
Revised December 7, 2017  
CY7C65221  
Contents  
Pin Configuration .............................................................3  
Pin Description .................................................................4  
Functional Overview ........................................................5  
Bridge register space ..................................................5  
Bridge I2C Interface ..................................................13  
I2C slave address ......................................................14  
Bridge BMC-FX3S Communication ...........................15  
Data protection ..........................................................16  
Clock stretching .........................................................16  
Register write-enable masks .....................................16  
Bridge Firmware upgrade ..........................................16  
Electrical Specifications ................................................17  
Absolute Maximum Ratings .......................................17  
Operating Conditions .................................................17  
Device-Level Specifications ......................................17  
GPIO .........................................................................18  
nXRES .......................................................................19  
I2C Specifications ......................................................19  
Flash Memory Specifications ....................................19  
Ordering Information ......................................................20  
Ordering Code Definitions .........................................20  
Package Information ......................................................21  
Acronyms ........................................................................22  
Document Conventions .................................................22  
Units of Measure .......................................................22  
Document History Page .................................................23  
Sales, Solutions, and Legal Information ......................24  
Worldwide Sales and Design Support .......................24  
Products ....................................................................24  
PSoC®Solutions .......................................................24  
Cypress Developer Community .................................24  
Technical Support .....................................................24  
Document Number: 001-89547 Rev. *C  
Page 2 of 24  
CY7C65221  
Pin Configuration  
24 23 22 21 20 19  
NC  
NC  
18  
17  
B_ADDR0  
VSSA  
1
2
CY7C65221  
24-pin QFN  
TOP View  
VSSD  
I2C_SCL_A  
I2C_SDA_A  
3
4
5
6
16  
15  
VSSD  
VDDD  
XRES#  
14  
13  
SWD Data  
VSSD  
7
8
9
10 11 12  
Document Number: 001-89547 Rev. *C  
Page 3 of 24  
CY7C65221  
Pin Description  
Pin  
1
Type  
NC  
Name  
NC  
Description  
2
NC  
NC  
3
Power  
Input  
VSSD  
Digital Ground  
4
I2C_SCL_A  
I2C_SDA_A  
SWD Data  
SWD Clock  
A_ADDR0  
A_ADDR1  
VSSD  
Port A I2C Clock. 400 KHz max  
Port A I2C data  
5
Input / Output  
Input / Output  
Input  
6
In-system serial programming and debug data  
In-system serial programming and debug Clock  
Port A I2C base address select, bit 0  
Port A I2C base address select, bit 1  
Digital Ground  
7
8
Input  
9
Input  
10  
11  
12  
Power  
Power  
Power  
VSSD  
Digital Ground  
VCCD  
This pin is an output of an internal regulator and cannot drive external devices.  
Decouple this pin to ground using 1 µF capacitor when the VCCIO voltage is greater  
then 2 V. Connect this pin to VCCIO supply when the VCCIO voltage is less then 2 V.  
13  
14  
Power  
Input  
VSSD  
Digital Ground  
XRES#  
Chip reset, active low. Can be left unconnected or have a pull-up resistor connected  
to VCCIO supply.  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
Power  
Power  
VDDD  
VSSD  
Supply to the device core. 3.3 V to 5.5 V  
Digital Ground  
Power  
VSSA  
Analog Ground  
Input  
B_ADDR0  
B_ADDR1  
INT_B#  
Port B I2C base address select, bit 0  
Port B I2C base address select, bit 0  
Port B I2C interrupt request  
Port B I2C Clock. 400 KHz max  
Port B I2C data  
Input  
Output  
Input  
I2C_SCL_B  
I2C_SDA_B  
FS#  
Input / Output  
Input / Output  
Power  
Fail safe Input  
VDDD  
Supply to the device core and interface, 1.71 V to 5.5 V  
Document Number: 001-89547 Rev. *C  
Page 4 of 24  
CY7C65221  
only provides the required field mask option for the data bytes  
and does not decode the writes to this address space except for  
Functional Overview  
two  
specific  
registers  
provided  
by  
the  
Bridge  
Bridge register space  
(I2C_A_WRITE_ADDR and I2C_A_WRITE_SIZE). Whenever  
there is a write operation from the BMC interface, the Bridge  
updates I2C_A_WRITE_ADDR and I2C_A_WRITE_SIZE  
registers and interrupts FX3S by asserting the INT_B line. The  
I2C_A interface shall be clock stretched until the FX3S  
de-asserts the INT_B line.  
The 256 byte address space is divided into three areas:  
BMC-FX3S register space, Bridge register space and Bridge  
buffer space. The legend used in the following register definitions  
are:  
Table 1. Register Space Legend  
Bridge register space  
Legend  
Description  
I2C_A (BMC) interface  
The Bridge register space occupies locations 0x1E, 0x1F and  
0x60-0x7F. This space is maintained by the Bridge and allows  
for configuration and operation of the Bridge. These are special  
registers which are expected to be used only from the I2C_B  
(FX3S) interface. However, the Bridge does not prevent access  
A
B
I2C_B (FX3S) interface  
Bridge  
Br  
RW  
RS  
Read write access  
Read and Set only  
to  
these  
registers  
from  
I2C_A  
interface.  
The  
I2C_A_WRITE_ADDR and I2C_A_WRITE_SIZE registers are  
placed at 0x1E and 0x1F so that FX3S can read the complete  
32 byte BMC register space in a single read.  
BMC-FX3S register space  
The following are the Bridge special function registers:  
The BMC-FX3S register space occupies locations 0x00 to 0x5F.  
This space is maintained by FX3S (I2C_B) interface. The Bridge  
I2C_A_WRITE_ADDR  
This register along with I2C_A_WRITE_SIZE register allows FX3S to easily identify the last modified address from the BMC side. The  
Bridge updates the ADDR field whenever BMC finishes a write to the BMC-FX3S register space on I2C_A interface.  
I2C_A_WRITE_ADDR  
Field Field Name  
Bit [7:0] ADDR  
0x1E  
A
Br  
B
Description  
R
RW  
R
The register holds the last updated start  
address from I2C_A interface to BMC register  
space. This allows FX3S to identify the write  
location from BMC side.  
I2C_A_WRITE_SIZE  
This register along with I2C_A_WRITE_ADDR register allows FX3S to easily identify the last modified register space from the BMC  
side. The Bridge updates this register whenever the BMC finishes a write to the BMC-FX3SA register space on I2C_A interface.  
I2C_A_WRITE_SIZE  
Field Field Name  
Bit [7:0] SIZE  
0x1F  
A
Br  
B
Description  
R
RW  
R
Theregister holds the size of the last write from  
I2C_A interface to BMC register space. This  
allows FX3S to identify the write location from  
BMC side.  
Document Number: 001-89547 Rev. *C  
Page 5 of 24  
CY7C65221  
BRIDGE_VERSION  
The register holds the Bridge firmware version information. This is a read-only field from both I2C interfaces. This field can be used  
to determine whether the Bridge firmware matches the FX3S firmware and whether the Bridge requires a firmware upgrade.  
BRIDGE_VERSION  
Field Field Name  
Byte[0]  
0x60–0x63  
Description  
A
Br  
B
MAJOR_ VERSION  
MINOR_ VERSION  
PATCH_ VERSION  
R
R
The byte represents the major firmware  
revision number.  
Byte[1]  
R
R
R
R
The byte represents the minor firmware  
revision number.  
Byte[3-2]  
The word represents the patch revision  
number.  
BRIDGE_BUILD  
The register holds the Bridge firmware build number. This is a read-only register from the I2C interfaces.  
BRIDGE_BUILD  
0x64–0x67  
Description  
Field  
Byte[3-0]  
Field Name  
A
Br  
B
BUILD_ NUMBER  
R
R
The byte represents the Bridge firmware build  
number.  
BRIDGE_MODE  
The register holds the active firmware number. This is a read-only register from the I2C interfaces.  
BRIDGE_MODE  
Field Field Name  
Bit [7:0] OP_MODE  
0x68  
A
Br  
B
Description  
R
R
0 – Primary (fail-safe) firmware active  
1 – Secondary firmware active.  
Document Number: 001-89547 Rev. *C  
Page 6 of 24  
CY7C65221  
I2C_CTRL  
The register allows the FX3S interface to configure I2C_A interface. The lower nibble holds configuration for I2C_A interface and  
upper nibble holds configuration information for I2C_B interface.  
I2C_CTRL  
Field Name  
0x69  
Field  
Bit [0]  
A
Br  
B
Description  
I2C_A_ENABLE  
R
RW 0 – Disable I2C_A interface. When  
disabled, the interface shall NAK any  
request.  
1 – Enable I2C_A interface. The reset  
value of this field is 0.  
Bit [4:1]  
Bit [5]  
Reserved  
R
R
R
Reserved.  
INT_B_CLEAR  
RW This bit is used by FX3S interface to  
de-assert the INT_B line.  
0 – Do nothing  
1 – Bridge shall de-assert INT_B and clear  
this bit.  
Read of this bit shall indicate the current  
status of the INTR line. If INTR line is  
asserted the bit shall be set, otherwise it  
shall be 0.  
Bit [7:6]  
Reserved  
R
R
Reserved.  
BRIDGE_RESET  
The register allows the I2C interfaces to reset the Bridge. The reset operation only performs a soft reset and a hard reset can only be  
done by asserting the XRES line on the Bridge.  
BRIDGE_RESET  
Field Name  
RESET_ SIGNATURE RW  
0x6A–0x6B  
Description  
Field  
Byte [0]  
A
Br  
B
RW  
RW The Bridge shall allow reset only if this  
byte is loaded with 0xAD (~R). The default  
value for this field is 0. Once the Bridge  
acts on the reset request, the field is again  
reset to 0. This is to prevent spurious  
reset.  
Byte[1]: Bit [0]  
RESET  
RW  
R
RW Request a reset.  
0 – Do nothing  
1 – Request for a reset. A read to this field  
will always return 0.  
Byte[1]: Bit [7:1] Reserved  
R
Reserved.  
Document Number: 001-89547 Rev. *C  
Page 7 of 24  
CY7C65221  
BRIDGE_MODE_RQT  
The register allows the I2C interfaces to request to Bridge to jump to fail-safe mode. This operation shall result in resetting the Bridge.  
On subsequent power cycle or reset, the device shall boot back to secondary image if a valid secondary image is available. This  
register is required for doing a firmware upgrade.  
BRIDGE_MODE_RQT  
Field Field Name  
0x6C–0x6D  
Description  
A
Br  
B
Byte [0]  
MODE_RQT_  
SIGNATURE  
RW  
RW  
RW The Bridge shall honor the request only if  
this byte is loaded with 0xB2 (~M). The  
default value for this field is 0. Once the  
Bridge acts on the request, the field is  
again reset to 0.  
Byte[1]: Bit [0]  
MODE_RQT  
RW  
RW Request a fail-safe entry.  
0 – Do nothing  
1 – Request for a fail-safe entry. The  
Bridge shall jump to primary firmware if  
running in secondary firmware mode.  
Otherwise nothing is done.  
A read to this field will always return 0.  
Byte[1]: Bit [7:1] Reserved  
R
R
Reserved.  
Document Number: 001-89547 Rev. *C  
Page 8 of 24  
CY7C65221  
BRIDGE_SPL_RQT  
The register allows for various special functions which use the upper 128 byte buffer area of the Bridge. The I2C interfaces are first  
expected to load the information into the upper 128 byte buffer area and then indicate the completion by writing to this register. Only  
one bit in the register can be set at a time. If more than one bit is set, the Bridge shall treat it as a bad request. On completion of a  
request, the Bridge shall clear the request bits and then load the status of the request into the signature field. If the request was  
completed successfully, the signature field shall be made zero. The field shall be non-zero if the request failed. The return error codes  
are:  
Error code  
SUCCESS  
Value  
Description  
Request was completed successfully.  
Request had bad arguments.  
Device is not ready to take the request.  
Request handling timed out.  
0
1
BAD_ARGUMENT  
NOT_CONFIGURED  
TIMEOUT  
3
8
NOT_SUPPORTED  
ERROR_FAILURE  
10  
14  
Request currently not supported.  
General request failure.  
BRIDGE_SPL_RQT  
Field Name  
0x6E–0x6F  
Description  
Field  
Byte [0]  
A
Br  
B
SPL_RQT_ SIGNATURE  
RW  
RW  
RW The Bridge shall honor the request only if this byte is  
loaded with 0xB9 (~F). The default value for this field is 0.  
Once the Bridge acts on the request, the field is again  
reset to 0.  
Byte[1]: Bit [0]  
Byte[1]: Bit [1]  
Byte[1]: Bit [2]  
FW_IMG_RQT  
RW  
RW  
RW  
RW Indicate to the Bridge that 128 bytes of firmware image for  
upgrade has been loaded into the buffer area.  
0 – Do nothing  
1 – FW image indication. The Bridge shall clear the field  
on programming the flash.  
A read to this field will always return 0.  
I2C_A_MASK_ RQT  
I2C_B_MASK_ RQT  
RW Indicate to the Bridge that 96 bytes of field write enable  
mask for I2C_A interface is loaded into the buffer area.  
0 – Do nothing  
1 – Buffer available indication. The Bridge shall clear the  
field on programming the flash.  
A read to this field will always return 0.  
RW Indicate to the Bridge that 96 bytes of field write enable  
mask for I2C_B interface is loaded into the buffer area.  
0 – Do nothing  
1 – Buffer available indication. The Bridge shall clear the  
field on programming the flash.  
A read to this field will always return 0.  
Byte[1]: Bit [3]  
Byte[1]: Bit [4]  
FW_IMG_ ABORT  
RW  
R
RW Abort any in progress firmware upgrade operation. After  
this the secondary image cannot be used.  
FW_IMG_ IN_PROG  
R
Firmware upgrade is in progress. The secondary image is  
valid only after the complete image is sent across over the  
I2C interface. This bit is set when Bridge starts updating  
the first section of the secondary image and is cleared on  
receiving the last section or in case of any error.  
Byte[1]: Bit [7:5] Reserved  
R
R
Reserved.  
Document Number: 001-89547 Rev. *C  
Page 9 of 24  
CY7C65221  
BRIDGE_MEMORY_OP  
This register allows the bridge to read and update the Flash and RAM locations. For write operation, the I2C master shall first load  
the data in the buffer area and then indicate the completion by writing to this register. For read operation, the I2C master is first  
expected to write to the register with read request. Bridge shall update the buffer area with the requested data bytes. Similar to  
BRIDGE_SPL_RQT, on completion of a request, the Bridge shall clear the request bits and then load the status of the request into  
the signature field. If the request was completed successfully, the signature field shall be made zero. The field shall be non zero, if  
the request failed. For flash operation, data size shall always be 128(Flash Row Size). The flash address should be a 128 bytes  
multiple. Flash operations are supported only in FAIL SAFE mode.  
BRIDGE_MEMORY_OP  
Field Name  
0x72–0x78  
Field  
Byte [0]  
A
Br  
B
Description  
MEMORY_OP_ SIGNATURE  
R
RW  
RW The Bridge shall honor the request only if  
this byte is loaded with 0xBA. The default  
value for this field is 0. Once the Bridge acts  
on the request, the field is again reset to 0.  
Byte[1]: Bit [0]  
Byte[1]: Bit [1]  
WRITE_READ  
R
R
RW Indicates to the bridge if the request is for  
memory read or write.  
0 – Read  
1 – Write  
A read to this field will always return 0.  
FLASH_RAM  
RW Indicates to the bridge if the request is for  
FLASH or RAM operation.  
0 – RAM  
1 – FLASH  
A read to this field will always return 0.  
Byte[1]: Bit [2:7] Reserved  
R
R
R
Reserved.  
Byte[2:5]:  
ADDRESS  
RW The memory address for read or update. As  
mentioned above, the address shall be  
multiple of 128 for FLASH operations. For  
RAM operations, address should be 32 bit  
aligned.  
Byte[6]:  
COUNT  
R
RW The count of bytes (4 Bytes) to read or write.  
For FLASH operation, this field is ignored as  
flash operations shall be 128 bytes only. For  
RAM operations, the count shall be 32 or  
less as the size of bridge buffer area is 128  
bytes (32 words).  
Document Number: 001-89547 Rev. *C  
Page 10 of 24  
CY7C65221  
BRIDGE_TIMEOUT_RQT  
This register allows the bridge to update the timeout duration for both the interfaces. The default timeout is 500 ms. On completion of  
a request, bridge shall load the status of the request into the signature field. If the request was completed successfully, the signature  
field shall be made zero. The field shall be non zero, if the request failed.  
BRIDGE_TIMEOUT_RQT  
Field Name  
0x7B–0x7D  
Field  
Byte [0]  
A
Br  
B
Description  
TIMEOUT_RQT SIGNATURE  
R
RW  
RW The Bridge shall honor the request only if  
this byte is loaded with 0xBB. The default  
value for this field is 0. Once the Bridge  
successfully acts on the request, the field is  
again reset to 0.  
Byte[1:2]  
TIMEOUT_VALUE (ms)  
R
RW This field shall be set with the timeout value.  
The minimum timeout supported by the  
bridge is 100ms. Any value less than that  
will be flagged as an error. To disable  
timeout detection feature this field shall be  
set with 0xFFFF. The timeout value shall be  
updated after the completion of the current  
I2C write request and I2C master on both  
interface shall read this field to determine  
the current timeout value The byte order is  
little endian.  
Document Number: 001-89547 Rev. *C  
Page 11 of 24  
CY7C65221  
BRIDGE_STATUS  
This register shall be used to determine the current status of both I2C interfaces. It shall flag any I2C bus, timeout and state machine  
errors detected on the interfaces. The lower nibble shall be reserved for I2C_A interface and the upper nibble for I2C_B interface. In  
case of any error bridge shall reset the corresponding I2C interface.  
BRIDGE_STATUS  
Field Name  
0x7E  
Field  
A
Br  
B
Description  
Bit[0]  
I2C_A_TIMEOUT_ERROR  
R
RW  
RW The bit shall be set if a timeout error is  
encounteredonI2C_Ainterface. Thebridge  
shall de-assert the INT _B line and reset the  
I2C_A interface. Write with 1 to clear the bit.  
Bit[1]  
Bit[2]  
I2C_A_BUS_ERROR  
R
R
RW  
RW  
RW This bit shall be set by bridge if an I2C Bus  
error or arbitration error is detected on  
I2C_A interface. Write with 1 to clear the bit.  
I2C_A_INVALID_CMD_ERROR  
RW This bit shall be set by bridge if a state  
machine error is detected due to invalid  
sequence of I2C commands from the  
master on I2C_A interface. Write Restart,  
Write across register boundaries and Write  
rollback to 0 are examples of such error.  
Write with 1 to clear the bit.  
Bit[3]  
Bit[4]  
RESERVED  
Reserved for future use.  
I2C_B_TIMEOUT_ERROR  
R
RW  
RW The bit shall be set if a timeout error is  
encountered on I2C_B interface. Write with  
1 to clear the bit.  
Bit[5]  
Bit[6]  
I2C_B_BUS_ERROR  
R
R
RW  
RW  
RW This bit shall be set by bridge if an I2C Bus  
error or arbitration error is detected on  
I2C_B interface. Write with 1 to clear the bit.  
I2C_B_INVALID_CMD_ERROR  
RW This bit shall be set by bridge if a state  
machine error is detected due to invalid  
sequence of I2C commands from the  
master on I2C_B interface. Write Restart,  
Write across register boundaries and Write  
rollback are examples of such error. Write  
with 1 to clear the bit.  
Bit[7]  
RESERVED  
Reserved for future use.  
Document Number: 001-89547 Rev. *C  
Page 12 of 24  
CY7C65221  
Bridge Buffer Space  
Figure 2 shows the bus sequence for a random read operation  
of two data bytes from the Bridge. The read operation consists  
of two parts: 1) Address update sequence; 2) followed by read  
operation. The address update sequence is essentially a write  
operation without any data bytes. The read operation follows this  
with a re-start signal on the bus. The read option allows for  
reading one or more bytes from the Bridge from the address  
specified. For read operation, if the read address overflows the  
256 byte boundary, then the address shall wrap around and the  
current address shall be made as zero. The read operation is not  
failed in this case. This read operation model is the  
recommended read operation mode as it uses re-start instead of  
a start followed by a stop. On a multi-master bus, a re-start bit is  
generally treated as an atomic operation and the bus is freed  
only on seeing a stop bit. So the address phase and the data  
phase stay in sync.  
The Bridge provides 128 bytes of buffer space (0x80–0xFF). The  
buffer area is used for FX3S firmware upgrade.  
2
Bridge I C Interface  
The Bridge provides EEPROM like access to its internal registers  
/ buffers. It exposes a byte addressed 8 bit register space. The  
lower 128 byte space is expected to be used as control / status  
registers for the Bridge communication while the upper 128 byte  
space is expected to be used as data buffer space for  
communication. The Bridge I2C interfaces support EEPROM like  
read / writes access. The following are the operations supported  
at the I2C interface:  
WRITE  
Figure 1. Bridge Write Sequence  
SEQUENTIAL READ  
S
T
A M  
R S  
T
W
R
I
T
E
S
T
O
P
Figure 3. Bridge Sequential Read Sequence  
M
S
B
M
S
B
M
S
B
DEVICE ADDR  
ADDR  
S
B
DATA0  
DATA1  
R
E
A
D
S
T
O
P
T
A
R
T
N
C
K
A
C
K
A
C
K
A
C
K
A
C
K
A
C
K
DEVICE ADDR  
A
C
K
M
S
B
M
S
B
DATA0  
DATA1  
Figure 1 shows the bus sequence for a write operation of two  
data bytes to the Bridge. The first byte following a write preamble  
shall always be the start address of the write operation. Any  
subsequent data bytes shall be written down to the register area.  
While the data is being received on the I2C bus, the Bridge stores  
the information in a temporary buffer and updates the register  
space only on receiving a stop signal on the bus. The writes are  
done after validating the write and only the fields which are  
write-enabled are updated. A write operation always needs to be  
terminated by a stop signal and a re-start after a write operation  
is not allowed. The write request allows for one or more register  
location writes in a single operation. The maximum allowed write  
size is 128 bytes. Any write that crosses the 256 byte boundary  
shall result in a failed write and none of the bytes in the write  
operation shall get updated. Any write which crosses boundaries  
(BMC-FX3S register space – Bridge register space – Buffer  
space), shall result in a failed write and none of the bytes in the  
write operation shall get updated.  
Figure 3 shows the bus sequence for a sequential read operation  
of two data bytes. A sequential read allows reading data from the  
current read location. The current read location gets updated on  
any read / write operation. The address is incremented on every  
byte read / written from / to the Bridge interface. The read  
operation is similar to the random read operation but on a  
multi-master bus, there shall be no guarantee that the read  
address shall not get modified between transactions resulting in  
wrong address location to be read back.  
SET ADDRESS  
Figure 4. Bridge Set Address Sequence  
S
T
A
R
T
W
R
I
S
T
O
P
M
S
B
T
E
DEVICE ADDR  
REG ADDR  
RANDOM READ  
Figure 2. Bridge Random Read Sequence  
A
C
K
A
C
K
S
T
A
R
T
W
R
I
T
E
S
T
A
R
T
R
E
A
D
S
T
O
P
M
S
B
M
S
B
A
C
K
N
C
K
DEVICE ADDR  
REG ADDR  
DEVICE ADDR  
A
C
K
A
C
K
A
C
K
M
S
B
M
S
B
DATA0  
DATA1  
The SET ADDRESS operation is a partial write / random read  
operation, where only the address location gets updated  
followed by a stop signal on the bus.  
Document Number: 001-89547 Rev. *C  
Page 13 of 24  
CY7C65221  
2
I C slave address  
The Bridge I2C address is derived during boot and is not dynamically changed. The address has two components: 1) Fixed 5 MS bits  
and 2) Configurable 2 LS bits. The following tables indicate the I2C slave address used for each interface.  
I2C_A interface address  
A_ADDR1 and A_ADDR0 are the states of the I/O lines at boot.  
I2C_A Address  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
1
1
0
0
0
A_ADDR1  
A_ADDR0  
I2C_B interface address  
B_ADDR1 and B_ADDR0 are the states of the I/O lines at boot.  
I2C_A Address  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
1
1
0
0
0
B_ADDR1  
B_ADDR0  
Document Number: 001-89547 Rev. *C  
Page 14 of 24  
CY7C65221  
Bridge BMC-FX3S Communication  
The BMC communicates with the Bridge through the I2C_A interface while the FX3S uses the I2C_B interface. The BMC and FX3S  
have full read access to the 256 byte register space of the Bridge. The BMC and FX3S have different read only fields which cannot  
be updated.  
Actual protocol to be used for FX3S Raid Solution is documented in “Internal Dual Secure Digital Module Specification” provided by  
Dell. Figure 5 describes a typical operation sequence for a BMC request to the FX3S.  
Figure 5. BMC Request Operation Sequence  
BRIDGE  
I2C_B MASTER  
I2C_A MASTER  
START REQUEST  
INITIATE REQUEST  
UPDATE  
I2C_A_WR_ADDR  
AND  
I2C_A_WR_SIZE  
ASSERT INT_B  
READ BRIDGE  
REGISTER SPACE  
READ STATUS  
REGISTER  
PERFORM  
REQUESTED  
OPERATION  
UPDATE STATUS  
REGISTERS  
SLAVE  
CLOCK  
STRETCH  
REQUEST CLEAR  
INT_B  
DE-ASSERT INT_B  
END REQUEST  
BMC initiates a request by writing into the Bridge register space.  
Once BMC completes the register write with a stop signal on the  
I2C bus, the Bridge updates the register memory and then  
updates the I2C_A_WRITE_ADDR and I2C_A_WRITE_SIZE  
registers with information about the BMC write. Once this is  
done, it initiates an interrupt to FX3S by asserting the INT_B line.  
It shall then perform the requested operation and then update the  
Bridge register space with the status information. Once FX3S  
has updated the status register space, it is expected to clear the  
INT_B interrupt. On clearing the INT_B interrupt, the Bridge shall  
de-assert the INT_B line.  
The BMC needs to poll the Bridge status register for completion  
of the request.  
FX3S on receiving an interrupt on INT_B line shall read the  
Bridge register space to determine the type of request received.  
Document Number: 001-89547 Rev. *C  
Page 15 of 24  
CY7C65221  
Bridge. The Bridge uses this mask information to allow writes to  
go through to the register space. The 32 byte area above this is  
Bridge register information and cannot be modified. The upper  
128 byte is fully writeable from both directions. Addresses 0x1E  
and 0x1F are always read-only from both interfaces. The Bridge  
by default allows writes to the first 96 bytes from both sides. The  
mask information has to be updated by FX3S on boot every time  
using the BRIDGE_SPL_RQT register based on the Dell register  
space requirement. For updating the write enable mask  
information for I2C_A interface, load the 96 byte mask  
information into the buffer space and then set the  
I2C_A_MASK_RQT bit in BRIDGE_SPL_RQT register. The  
Bridge firmware on receiving the request, shall update the local  
RAM copy with the new information. I2C_B interface mask  
information can be updated similarly. This information is not  
retained across Bridge reset and has to be loaded every time.  
Data protection  
The Bridge register space can be accessed from both I2C_A and  
I2C_B interface. This results in possibility of the same register  
being accessed at the same time from both the interface. The  
Bridge allows only one interface to access the Bridge at one time.  
The first access is accepted and the second interface in the  
event of a contention is clock stretched in the preamble phase.  
The preamble shall not be ACKd and the clock line stretched until  
the first interface completes the access.  
Additionally, since the Bridge status register has to be updated  
by FX3S, once BMC completes a write to the lower 128 byte  
area, the Bridge shall clock stretch any further request from BMC  
until FX3S clears the INT_B interrupt. This allows FX3S time to  
update the status register before BMC can read the status  
registers.  
Clock stretching  
Bridge Firmware upgrade  
The Bridge shall use clock stretching on both I2C interfaces until  
it is ready to take any new request. The clock shall be stretched  
at the following modes:  
The Bridge firmware upgrade can be done by loading the  
firmware image 128 byte at a time into the Bridge buffer area and  
trigger the flash programming by writing to the FW_IMG_RQT bit  
of the BRIDGE_SPL_RQT register. The Bridge shall decode the  
firmware image and then load the data to the required location.  
On receiving the last 128 byte packet of firmware image, the  
Bridge shall update the checksum and signature information to  
the checksum page in flash for the corresponding image.  
1. At the ACK / NAK phase of preamble / data bytes.  
2. After DATA ACK If the RX FIFO is full and cannot receive any  
more data.  
Register write-enable masks  
The I2C_A interface as well as I2C_B interface has two different  
write enable masks for the first 96 byte register area in the  
Document Number: 001-89547 Rev. *C  
Page 16 of 24  
CY7C65221  
Electrical Specifications  
Static discharge voltage ESD protection levels:  
Absolute Maximum Ratings  
Exceeding maximum ratings[1] may shorten the useful life of the  
device.  
2.2-KV HBM per JESD22-A114  
Latch-up current ........................................................... 140 mA  
Current per GPIO ........................................................... 25 mA  
Storage temperature .................................... –55 °C to +100 °C  
Ambient temperature with  
Operating Conditions  
power supplied (Industrial) ............................ –40 °C to +85 °C  
Supply voltage to ground potential  
VDDD ................................................................................. 6.0 V  
TA (ambient temperature under bias)  
Industrial ........................................................ –40 °C to +85 °C  
VCCD ............................................................................... 1.95 V  
VGPIO ....................................................................... VDDD + 0.5  
V
DDD supply voltage ........................................ 1.71 V to 5.50 V  
VCCD supply voltage ........................................ 1.71 V to 1.89 V  
Device-Level Specifications  
All specifications are valid for –40 °C TA 85 °C, TJ 100 °C, and 1.71 V to 5.50 V, except where noted.  
Table 2. DC Specifications  
Parameter  
VDDD  
Description  
Min  
1.71  
2.0  
Typ  
1.80  
3.3  
Max  
1.89  
5.5  
Units  
Details/Conditions  
VDDD supply voltage  
V
V
Used to set I/O and core voltage. Set  
and configure the correct voltage  
range using a configuration utility for  
VDDD. Default 3.3 V.  
VCCD  
Output voltage (for core logic)  
1.80  
V
Do not use this supply to drive the  
external device.  
• 1.71 V VDDD 1.89 V: Short the  
VCCD pin with the VDDD pin  
• VDDD > 2 V – connect a 1-µF  
capacitor (Cefc) between the VCCD  
pin and ground  
Cefc  
IDD1  
External regulator voltage bypass  
Operating Supply Current  
1.00  
1.30  
7.25  
1.60  
12  
µF  
X5R ceramic or better  
I2C at 400 kHz dual channel  
mA  
Table 3. AC Specifications  
Parameter  
Description  
Min  
Typ  
Max  
48.96  
Units  
MHz I2C Bridge  
Details/Conditions  
F1  
Frequency  
47.04  
48  
Note  
1. Usage above the Absolute Maximum conditions may cause permanent damage to the device. Exposure to Absolute Maximum conditions for extended periods of  
time may affect device reliability. When used below Absolute Maximum conditions but above normal operating conditions, the device may not operate to specification.  
Document Number: 001-89547 Rev. *C  
Page 17 of 24  
CY7C65221  
GPIO  
Table 4. GPIO DC Specification  
Parameter  
Description  
Min  
Typ  
Max  
Units  
Details/Conditions  
CMOS Input  
CMOS Input  
[2]  
VIH  
Input voltage high threshold  
Input voltage low threshold  
LVTTL input, VDDD < 2.7 V  
LVTTL input, VDDD < 2.7 V  
LVTTL input, VDDD > 2.7 V  
LVTTL input, VDDD > 2.7 V  
0.7 × VDDD  
V
V
V
V
V
V
V
VIL  
VIH  
VIL  
VIH  
VIL  
0.3 × VDDD  
[2]  
[2]  
0.7 × VDDD  
0.3 × VDDD  
2
0.8  
VOH  
VOH  
VOH  
VOL  
VOL  
VOL  
Output voltage high level CMOS  
Output  
VDDD –0.4  
IOH = 4 mA,  
VDDD = 5 V +/- 10%  
Output voltage high level CMOS  
Output  
VDDD –0.6  
V
V
V
V
V
IOH = 4 mA,  
VDDD = 3.3 V +/- 10%  
Output voltage high level CMOS  
Output  
VDDD –0.5  
IOH = 1 mA,  
VDDD = 1.8 V +/- 5%  
Output voltage low level CMOS  
Output  
0.4  
0.6  
0.6  
IOL = 8 mA,  
VDDD = 5 V +/- 10%  
Output voltage low level CMOS  
Output  
IOL = 8 mA,  
VDDD = 3.3 V +/- 10%  
Output voltage low level CMOS  
Output  
IOL = 4 mA,  
VDDD = 1.8 V +/- 5%  
Rpullup  
Rpulldown  
IIL  
Pull-up resistor  
3.5  
3.5  
5.6  
5.6  
8.5  
8.5  
2
k  
kΩ  
Pull-down resistor  
Input leakage current (absolute  
value)  
nA 25 °C, VDDD = 3.0 V  
CIN  
Input capacitance  
7
pF  
Vhysttl  
Input hysteresis LVTTL; VDDD  
2.7 V  
>
25  
40  
C
mV  
Vhyscmos  
Input hysteresis CMOS  
0.05 × VDDD  
mV  
Table 5. GPIO AC Specification  
Parameter  
Description  
Min  
Typ  
Max  
Units  
Details/Conditions  
TRiseFast1  
Rise Time in Fast mode  
Fall Time in Fast mode  
Rise Time in Slow mode  
Fall Time in Slow mode  
2
12  
ns VDDD = 3.3 V/ 5.5 V,  
Cload = 25 pF  
TFallFast1  
TRiseSlow1  
TFallSlow1  
2
12  
60  
60  
ns VDDD = 3.3 V/ 5.5 V,  
Cload = 25 pF  
10  
10  
ns VDDD = 3.3 V/ 5.5 V,  
Cload = 25 pF  
ns VDDD = 3.3 V/ 5.5 V,  
Cload = 25 pF  
TRiseFast2  
TFallFast2  
TRiseSlow2  
TFallSlow2  
Rise Time in Fast mode  
Fall Time in Fast mode  
Rise Time in Slow mode  
Fall Time in Slow mode  
2
20  
2
20  
100  
20  
ns VDDD = 1.8 V, Cload = 25 pF  
ns VDDD = 1.8 V, Cload = 25 pF  
ns VDDD = 1.8 V, Cload = 25 pF  
ns VDDD = 1.8 V, Cload = 25 pF  
20  
100  
Note  
2.  
V
must not exceed V  
+ 0.2 V.  
IH  
DDD  
Document Number: 001-89547 Rev. *C  
Page 18 of 24  
CY7C65221  
nXRES  
Table 6. nXRES DC Specifications  
Parameter  
VIH  
Description  
Min  
Typ  
Max  
Units  
V
Details/Conditions  
Input voltage high threshold  
Input voltage low threshold  
Pull-up resistor  
0.7 × VDDD  
VIL  
3.5  
0.3 × VDDD  
V
Rpullup  
CIN  
5.6  
5
8.5  
kΩ  
pF  
Input capacitance  
Vhysxres  
Input voltage hysteresis  
100  
mV  
Table 7. nXRES AC Specifications  
Parameter  
Description  
Reset pulse width  
Min  
Typ  
Max  
Units  
Details/Conditions  
Details/Conditions  
Details/Conditions  
Tresetwidth  
1
µs  
2
I C Specifications  
Table 8. I2C AC Specifications  
Parameter  
FI2C  
Description  
I2C frequency  
Min  
Typ  
Max  
Units  
1
400  
kHz  
Flash Memory Specifications  
Table 9. Flash Memory Specifications  
Parameter  
Fend  
Fret  
Description  
Flash endurance  
Min  
100K  
10  
Typ  
Max  
Units  
cycles  
years  
Flash retention. TA 85 °C, 10 K  
program/erase cycles  
Document Number: 001-89547 Rev. *C  
Page 19 of 24  
CY7C65221  
Ordering Information  
Table 10 lists the key package features and ordering codes of the CY7C65211. For more information, contact your local sales repre-  
sentative.  
Table 10. Key Features and Ordering Information  
Package  
Ordering Code  
Operating Range  
24-pin QFN (4.00 × 4.00 × 0.55 mm, 0.5 mm pitch) (Pb-free)  
CY7C65221-24LTXI  
Industrial  
Ordering Code Definitions  
CY  
7
C
65 xxx  
-
xxLT  
X
I
Industrial  
Pb-free  
Package type: 24-pin QFN  
221  
Family Code  
Technology Code: C = CMOS  
Marketing Code: 7 = Cypress products  
Company Code: CY = Cypress  
Document Number: 001-89547 Rev. *C  
Page 20 of 24  
CY7C65221  
Package Information  
Support currently is planned for the 24-pin QFN package.  
Figure 6. 24-pin QFN (4 × 4 × 0.55 mm) LQ24A 2.65 × 2.65 E-Pad (Sawn) Package Outline, 001-13937  
001-13937 *F  
Table 11. Package Characteristics  
Parameter  
TA  
THJ  
Description  
Operating ambient temperature  
Package JA  
Min  
–40  
Typ  
25  
Max  
85  
Units  
°C  
18.4  
°C/W  
Table 12. Solder Reflow Peak Temperature  
Package  
Maximum Peak Temperature  
Maximum Time at Peak Temperature  
24-pin QFN  
260 °C  
30 seconds  
Table 13. Package Moisture Sensitivity Level (MSL), IPC/JEDEC J-STD-2  
Package  
MSL  
24-pin QFN  
MSL 3  
Document Number: 001-89547 Rev. *C  
Page 21 of 24  
CY7C65221  
Acronyms  
Document Conventions  
Table 14. Acronyms used  
Acronym  
Units of Measure  
Description  
Table 15. Units of Measure  
CMOS  
ESD  
GPIO  
HBM  
I/O  
Complementary Metal Oxide Semiconductor  
Electrostatic Discharge  
Symbol  
Unit of Measure  
C  
degree Celsius  
kilohm  
General Purpose Input/Output  
Human-Body Model  
k  
kHz  
kV  
kilohertz  
kilovolt  
Input/Output  
I2C  
Inter-Integrated Circuit  
MHz  
µF  
megahertz  
microfarad  
milliampere  
millimeter  
millivolt  
LVTTL  
QFN  
RoHS  
Low-Voltage Transistor-Transistor Logic  
Quad-Flat No-lead  
mA  
mm  
mV  
nA  
ns  
Restriction of Hazardous Substances  
nanoampere  
nanosecond  
picofarad  
volt  
pF  
V
W
watt  
Document Number: 001-89547 Rev. *C  
Page 22 of 24  
CY7C65221  
Document History Page  
Document Title: CY7C65221, Dual I2C Slave Bridge  
Document Number: 001-89547  
Orig. of  
Change  
Submission  
Date  
Revision  
ECN  
Description of Change  
**  
4150932  
4340874  
DTNK  
MVTA  
10/08/2013 New data sheet.  
*A  
04/11/2014 Changed status from Preliminary to Final.  
Updated Pin Description:  
Updated description of pin 12 and pin 14.  
Updated Functional Overview:  
Updated Bridge register space:  
Updated BMC-FX3S register space:  
Updated description.  
Updated Bridge register space:  
Updated description corresponding to “I2C_A_WRITE_ADDR”.  
Updated table corresponding to “I2C_CTRL”.  
Updated table corresponding to “BRIDGE_SPL_RQT”.  
Added details corresponding to “BRIDGE_MEMORY_OP”.  
Added details corresponding to “BRIDGE_TIMEOUT_RQT”.  
Added details corresponding to “BRIDGE_STATUS”.  
Updated Bridge I2C Interface:  
Updated WRITE:  
Updated description.  
Added Register write-enable masks.  
Added Bridge Firmware upgrade.  
Updated Electrical Specifications:  
Updated Device-Level Specifications:  
Updated Table 2:  
Added IDD1 parameter and its details.  
Updated GPIO:  
Updated Table 4:  
Updated description of VOH and VOL parameters.  
Updated Table 5:  
Updated all the details.  
*B  
*C  
5473879  
RAJV  
10/13/2016 Updated Package Information:  
spec 001-13937 – Changed revision from *E to *F.  
Updated to new template.  
Completing Sunset Review.  
5987021 AESATMP9 12/07/2017 Updated logo and copyright.  
Document Number: 001-89547 Rev. *C  
Page 23 of 24  
CY7C65221  
Sales, Solutions, and Legal Information  
Worldwide Sales and Design Support  
Cypress maintains a worldwide network of offices, solution centers, manufacturer’s representatives, and distributors. To find the office  
closest to you, visit us at Cypress Locations.  
®
Products  
PSoC Solutions  
ARM® Cortex® Microcontrollers  
cypress.com/arm  
cypress.com/automotive  
cypress.com/clocks  
cypress.com/interface  
cypress.com/iot  
PSoC 1 | PSoC 3 | PSoC 4 | PSoC 5LP | PSoC 6  
Automotive  
Cypress Developer Community  
Clocks & Buffers  
Interface  
Forums | WICED IOT Forums | Projects | Video | Blogs |  
Training | Components  
Internet of Things  
Memory  
Technical Support  
cypress.com/memory  
cypress.com/mcu  
cypress.com/support  
Microcontrollers  
PSoC  
cypress.com/psoc  
Power Management ICs  
Touch Sensing  
USB Controllers  
Wireless Connectivity  
cypress.com/pmic  
cypress.com/touch  
cypress.com/usb  
cypress.com/wireless  
© Cypress Semiconductor Corporation, 2013-2017. This document is the property of Cypress Semiconductor Corporation and its subsidiaries, including Spansion LLC ("Cypress"). This document,  
including any software or firmware included or referenced in this document ("Software"), is owned by Cypress under the intellectual property laws and treaties of the United States and other countries  
worldwide. Cypress reserves all rights under such laws and treaties and does not, except as specifically stated in this paragraph, grant any license under its patents, copyrights, trademarks, or other  
intellectual property rights. If the Software is not accompanied by a license agreement and you do not otherwise have a written agreement with Cypress governing the use of the Software, then Cypress  
hereby grants you a personal, non-exclusive, nontransferable license (without the right to sublicense) (1) under its copyright rights in the Software (a) for Software provided in source code form, to  
modify and reproduce the Software solely for use with Cypress hardware products, only internally within your organization, and (b) to distribute the Software in binary code form externally to end users  
(either directly or indirectly through resellers and distributors), solely for use on Cypress hardware product units, and (2) under those claims of Cypress's patents that are infringed by the Software (as  
provided by Cypress, unmodified) to make, use, distribute, and import the Software solely for use with Cypress hardware products. Any other use, reproduction, modification, translation, or compilation  
of the Software is prohibited.  
TO THE EXTENT PERMITTED BY APPLICABLE LAW, CYPRESS MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARD TO THIS DOCUMENT OR ANY SOFTWARE  
OR ACCOMPANYING HARDWARE, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. To the extent  
permitted by applicable law, Cypress reserves the right to make changes to this document without further notice. Cypress does not assume any liability arising out of the application or use of any  
product or circuit described in this document. Any information provided in this document, including any sample design information or programming code, is provided only for reference purposes. It is  
the responsibility of the user of this document to properly design, program, and test the functionality and safety of any application made of this information and any resulting product. Cypress products  
are not designed, intended, or authorized for use as critical components in systems designed or intended for the operation of weapons, weapons systems, nuclear installations, life-support devices or  
systems, other medical devices or systems (including resuscitation equipment and surgical implants), pollution control or hazardous substances management, or other uses where the failure of the  
device or system could cause personal injury, death, or property damage ("Unintended Uses"). A critical component is any component of a device or system whose failure to perform can be reasonably  
expected to cause the failure of the device or system, or to affect its safety or effectiveness. Cypress is not liable, in whole or in part, and you shall and hereby do release Cypress from any claim,  
damage, or other liability arising from or related to all Unintended Uses of Cypress products. You shall indemnify and hold Cypress harmless from and against all claims, costs, damages, and other  
liabilities, including claims for personal injury or death, arising from or related to any Unintended Uses of Cypress products.  
Cypress, the Cypress logo, Spansion, the Spansion logo, and combinations thereof, WICED, PSoC, CapSense, EZ-USB, F-RAM, and Traveo are trademarks or registered trademarks of Cypress in  
the United States and other countries. For a more complete list of Cypress trademarks, visit cypress.com. Other names and brands may be claimed as property of their respective owners.  
Document Number: 001-89547 Rev. *C  
Revised December 7, 2017  
Page 24 of 24  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY