MDU12H-10C3 [DATADELAY]

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H); DUAL , ECL -接口固定的延时线(系列MDU12H )
MDU12H-10C3
型号: MDU12H-10C3
厂家: DATA DELAY DEVICES, INC.    DATA DELAY DEVICES, INC.
描述:

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DUAL , ECL -接口固定的延时线(系列MDU12H )

延迟线 逻辑集成电路
文件: 总4页 (文件大小:33K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MDU12H  
Ò
DUAL, ECL-INTERFACED  
FIXED DELAY LINE  
(SERIES MDU12H)  
data  
delay  
3
devices, inc.  
FEATURES  
PACKAGES  
GND  
GND  
O1  
1
16  
15  
14  
1
2
3
4
5
6
7
8
16  
15  
14  
13  
12  
11  
10  
9
GND  
O1  
O2  
N/C  
N/C  
N/C  
N/C  
N/C  
GND  
N/C  
N/C  
N/C  
I1  
I2  
N/C  
VEE  
·
·
·
·
Two independent delay lines  
Fits standard 16-pin DIP socket  
Auto-insertable  
O2  
I1  
I2  
5
6
Input & outputs fully 10KH-ECL interfaced & buffered  
VEE  
8
MDU12H-xx DIP  
MDU12H-xxC3 SMD  
MDU12H-xxM Military DIP MDU12H-xxMC3 Mil SMD  
PIN DESCRIPTIONS  
FUNCTIONAL DESCRIPTION  
I1-I2  
O1-O2 Signal Outputs  
VEE -5 Volts  
GND Ground  
Signal Inputs  
The MDU12H-series device is a 2-in-1 digitally buffered delay line. The  
signal inputs (I1-I2) are reproduced at the outputs (O1-O2), shifted in time  
by an amount determined by the device dash number (See Table). The  
delay lines function completely independently of each other.  
DASH NUMBER SPECIFICATIONS  
SERIES SPECIFICATIONS  
Part  
Number  
Delay Per  
Line (ns)  
3 ± 1.0  
4 ± 1.0  
5 ± 1.0  
·
·
·
·
·
·
Minimum input pulse width: 50% of total delay  
Output rise time: 2ns typical  
Supply voltage: -5VDC ± 5%  
Power dissipation: 200mw typical (no load)  
Operating temperature: -30° to 85° C  
Temp. coefficient of total delay: 100 PPM/°C  
MDU12H-3  
MDU12H-4  
MDU12H-5  
MDU12H-10  
MDU12H-15  
MDU12H-20  
MDU12H-25  
MDU12H-30  
MDU12H-35  
MDU12H-40  
MDU12H-45  
MDU12H-50  
MDU12H-60  
MDU12H-75  
MDU12H-100  
MDU12H-125  
MDU12H-150  
MDU12H-200  
MDU12H-250  
10 ± 1.0  
15 ± 1.0  
20 ± 1.0  
25 ± 2.0  
30 ± 2.0  
35 ± 2.0  
40 ± 2.0  
45 ± 2.2  
50 ± 2.5  
60 ± 3.0  
75 ± 3.7  
100 ± 5.0  
125 ± 6.2  
150 ± 7.5  
200 ± 10.0  
250 ± 12.5  
O1  
100%  
I1  
O2  
100%  
I2  
VCC  
GND  
* Total delay is referenced to first tap output  
Input to first tap = 1.5ns ± 1ns  
Functional block diagram  
NOTE: Any dash number between 3 and 50  
not shown is also available.  
Ó1997 Data Delay Devices  
Doc #97038  
12/12/97  
DATA DELAY DEVICES, INC.  
3 Mt. Prospect Ave. Clifton, NJ 07013  
1
MDU12H  
APPLICATION NOTES  
Delay Devices if your application requires device  
testing at a specific input condition.  
HIGH FREQUENCY RESPONSE  
The MDU12H tolerances are guaranteed for  
input pulse widths and periods greater than those  
specified in the test conditions. Although the  
device will function properly for pulse widths as  
small as 50% of the total delay and periods as  
small as 100% of the total delay (for a symmetric  
input), the delays may deviate from their values  
at low frequency. However, for a given input  
condition, the deviation will be repeatable from  
pulse to pulse. Contact technical support at Data  
POWER SUPPLY BYPASSING  
The MDU12H relies on a stable power supply to  
produce repeatable delays within the stated  
tolerances. A 0.1uf capacitor from VEE to GND,  
located as close as possible to the VEE pin, is  
recommended. A wide VEE trace and a clean  
ground plane should be used.  
DEVICE SPECIFICATIONS  
TABLE 1: ABSOLUTE MAXIMUM RATINGS  
PARAMETER  
DC Supply Voltage  
Input Pin Voltage  
Storage Temperature  
Lead Temperature  
SYMBOL  
VEE  
VIN  
TSTRG  
TLEAD  
MIN  
-7.0  
VEE - 0.3  
-55  
MAX  
0.3  
0.3  
150  
300  
UNITS NOTES  
V
V
C
C
10 sec  
TABLE 2: DC ELECTRICAL CHARACTERISTICS  
(0C to 75C)  
PARAMETER  
SYMBOL  
VOH  
VOL  
VIH  
MIN  
-1.020  
-1.950  
TYP  
MAX  
-0.735  
-1.600  
-1.070  
UNITS  
NOTES  
VIH = MAX,50W to -2V  
VIL = MIN, 50W to -2V  
High Level Output Voltage  
Low Level Output Voltage  
High Level Input Voltage  
Low Level Input Voltage  
High Level Input Current  
Low Level Input Current  
V
V
V
V
mA  
mA  
VIL  
IIH  
IIL  
-1.480  
0.5  
475  
VIH = MAX  
VIL = MIN  
Doc #97038  
12/12/97  
DATA DELAY DEVICES, INC.  
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com  
2
MDU12H  
PACKAGE DIMENSIONS  
16 15 14  
.400  
TYP.  
1
5
6
8
.800 TYP.  
.320  
MAX.  
.020  
TYP.  
.150  
±.030  
.010 TYP.  
.100  
.018  
TYP.  
TYP.  
.300  
TYP.  
.700 TYP.  
MDU12H-xx (Commercial DIP)  
MDU12H-xxM (Military DIP)  
.020 TYP.  
.040  
.010±.002  
TYP.  
16 15 14 13 12 11 10  
9
.882  
±.005  
.710 .590  
MAX.  
±.005  
.007  
±.005  
1
2
3
4
5
6
7
8
.090  
.100  
.280  
MAX.  
.050  
±.010  
.700  
.880±.020  
MDU12H-xxC3 (Commercial SMD)  
MDU12H-xxMC3 (Military SMD)  
Doc #97038  
12/12/97  
DATA DELAY DEVICES, INC.  
3 Mt. Prospect Ave. Clifton, NJ 07013  
3
MDU12H  
DELAY LINE AUTOMATED TESTING  
TEST CONDITIONS  
INPUT:  
OUTPUT:  
Ambient Temperature: 25oC ± 3oC  
Supply Voltage (Vcc): -5.0V ± 0.1V  
Load:  
Cload  
50W to -2V  
5pf ± 10%  
:
Input Pulse:  
Standard 10KH ECL  
Threshold: (VOH + VOL) / 2  
levels  
(Rising & Falling)  
Source Impedance:  
Rise/Fall Time:  
50W Max.  
2.0 ns Max. (measured  
between 20% and 80%)  
PWIN = 1.5 x Total Delay  
PERIN = 10 x Total Delay  
Pulse Width:  
Period:  
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.  
REF  
PULSE  
GENERATOR  
OUT  
I1  
I2  
O1  
O2  
IN  
OSCILLOSCOPE  
TRIG  
DEVICE UNDER  
TEST (DUT)  
TRIG  
Test Setup  
PERIN  
PWIN  
VIH  
TRISE  
TFALL  
INPUT  
SIGNAL  
80%  
50%  
20%  
80%  
50%  
20%  
VIL  
TRISE  
TFALL  
OUTPUT  
SIGNAL  
VOH  
50%  
50%  
VOL  
Timing Diagram For Testing  
Doc #97038  
12/12/97  
DATA DELAY DEVICES, INC.  
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com  
4

相关型号:

MDU12H-10M

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-10MC3

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-125

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-125C3

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-125M

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-125MC3

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-15

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-150

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-150C3

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-150M

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-150MC3

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY

MDU12H-15C3

DUAL, ECL-INTERFACED FIXED DELAY LINE (SERIES MDU12H)
DATADELAY