FEATURES  
High efficiency: 94. 3% @ 12Vin, 5V/6A out  
Small size and low profile:  
12.2x 12.2x 7.25mm (0.48x 0.48x 0.29)  
Surface mount packaging  
Standard footprint  
Voltage and resistor-based trim  
Pre-bias startup  
Output voltage tracking  
No minimum load required  
Output voltage programmable from  
0.59Vdc to 5.0Vdc via external resistor  
Fixed frequency operation  
Input UVLO, output OCP  
Remote on/off  
ISO 9001, TL 9000, ISO 14001, QS9000,  
OHSAS18001 certified manufacturing  
facility  
UL/cUL 60950-1 (US & Canada)  
CE mark meets 73/23/EEC and 93/68/EEC  
directives  
Delphi DCS, Non-Isolated Point of Load  
DC/DC Power Modules: 4.5~14Vin, 0.59-5.0V/6Aout  
The Delphi Series DCS, 4.5-14V input, single output, non-isolated  
Point of Load DC/DC converters are the latest offering from a world  
leader in power systems technology and manufacturing -- Delta  
Electronics, Inc. The DCS series provides a programmable output  
voltage from 0.59 V to 5.0V using an external resistor and has flexible  
and programmable tracking features to enable a variety of startup  
voltages as well as tracking between power modules. This product  
family is available in surface mount and provides up to 6A of output  
current in an industry standard footprint. With creative design  
technology and optimization of component placement, these  
converters possess outstanding electrical and thermal performance,  
as well as extremely high reliability under highly stressful operating  
conditions.  
OPTIONS  
Negative/Positive on/off logic  
Tracking feature  
APPLICATIONS  
Telecom / DataCom  
Distributed power architectures  
Servers and workstations  
LAN / WAN applications  
Data processing applications  
DATASHEET  
DS_DCS12S0A0S06NFA_12072012  
TECHNICAL SPECIFICATIONS  
(TA = 25°C, airflow rate = 300 LFM, Vin =4.5Vdc and 14Vdc, nominal Vout unless otherwise noted.)  
PARAMETER  
NOTES and CONDITIONS  
DCS12S0A0S06NFA  
Min.  
Typ.  
Max.  
Units  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage (Continuous)  
Sequencing Voltage  
-0.3  
-0.3  
15  
V
Vin max  
V
Operating Ambient Temperature  
Storage Temperature  
-40  
-55  
85  
125  
INPUT CHARACTERISTICS  
Operating Input Voltage  
Vo Vin 0.6  
4.5  
14.0  
4.4  
V
Input Under-Voltage Lockout  
Turn-On Voltage Threshold  
Turn-Off Voltage Threshold  
Lockout Hysteresis Voltage  
Maximum Input Current  
V
V
V
A
3.2  
0.4  
Vin=4.5V to14V, Io=Io,max  
Vo,set = 0.6 Vdc  
6.0  
No-Load Input Current (VIN = 12.0Vdc, Io =  
0, module enabled)  
10  
25  
mA  
Vo,set = 3.3 Vdc  
mA  
mA  
Off Converter Input Current (VIN = 12.0Vdc,  
module disabled)  
0.8  
Inrush Transient  
1
A2S  
Input Reflected Ripple Current, peak-to-peak  
OUTPUT CHARACTERISTICS  
(5Hz to 20MHz, 1μH source impedance; Vin =0 to 14V,  
86  
mAp-p  
with 0.5% tolerance for external resistor used to set  
output voltage)  
(selected by an external resistor)  
Output Voltage Set Point  
-1.5  
Vo,set  
+1.5  
5.0  
%Vo,set  
V
Output Voltage Adjustable Range  
Output Voltage Regulation  
0.59  
For Vo>=2.5V  
For Vo<2.5V  
For Vo>=2.5V  
For Vo<2.5V  
0.4  
10  
10  
5
%Vo,set  
mV  
mV  
Line(VIN=VIN, min to VIN, max)  
Load(Io=Io, min to Io, max)  
mV  
For Vo>=2.5V  
For Vo<2.5V  
0.4  
5
%Vo,set  
mV  
Temperature(Tref=TA, min to TA, max)  
Total Output Voltage Range  
Output Voltage Ripple and Noise  
Over sample load, line and temperature  
5Hz to 20MHz bandwidth  
-2.5  
0
+2.5  
%Vo,set  
Peak-to-Peak  
Full Load, 1µF+10uF ceramic+47uF ceramic  
Full Load, 1µF+10uF ceramic+47uF ceramic  
30  
10  
60  
mV  
RMS  
20  
6
mV  
A
Output Current Range  
Output Voltage Over-shoot at Start-up  
Output DC Current-Limit Inception  
Output Short-Circuit Current (Hiccup Mode)  
DYNAMIC CHARACTERISTICS  
Dynamic Load Response  
Positive Step Change in Output Current  
Negative Step Change in Output Current  
Settling Time to 10% of Peak Deviation  
Turn-On Transient  
Vout=5.0V  
Io,s/c  
3
225  
% Vo,set  
% Io  
Adc  
0.5  
10µF Tan & 1µF Ceramic load cap, 2.5A/µs  
50% Io, max to 100% Io, max  
100% Io, max to 50% Io, max  
200  
200  
20  
mV  
mV  
µs  
Io=Io.max  
Start-Up Time, From On/Off Control  
Start-Up Time, From Input  
Output Voltage Rise Time  
Time for Von/off to Vo=10% of Vo,set  
Time for Vin=Vin,min to Vo=10% of Vo,set  
Time for Vo to rise from 10% to 90% of Vo,set  
Full load; ESR 0.15mΩ  
2
2
4
ms  
ms  
ms  
µF  
µF  
Output Capacitive Load  
47  
47  
800  
1800  
Full load; ESR 10mΩ  
EFFICIENCY  
Vo=5.0V  
Vo=2.5V  
Vo=1.2V  
Vo=0.59V  
Vin=12V, 100% Load  
Vin=12V, 100% Load  
Vin=12V, 100% Load  
Vin=12V, 100% Load  
94.3  
90.5  
82.9  
71.5  
%
%
%
%
FEATURE CHARACTERISTICS  
Switching Frequency  
ON/OFF Control, (Negative logic)  
Logic Low Voltage  
Logic High Voltage  
Logic Low Current  
Logic High Current  
ON/OFF Control, (Positive Logic)  
Logic High Voltage  
Logic Low Voltage  
Logic Low Current  
Logic High Current  
Tracking Slew Rate Capability  
Tracking Delay Time  
Tracking Accuracy  
600  
kHz  
Module On, Von/off  
Module Off, Von/off  
Module On, Ion/off  
Module Off, Ion/off  
-0.2  
3.5  
0.6  
Vin,max  
10  
V
V
µA  
mA  
1
Module On, Von/off  
Module Off, Von/off  
Module On, Ion/off  
Module Off, Ion/off  
3.0  
-0.3  
Vin,max  
0.6  
1
10  
2
V
V
mA  
µA  
V/msec  
ms  
mV  
mV  
0.1  
10  
Delay from Vin.min to application of tracking voltage  
Power-up  
2V/mS  
100  
100  
Power-down 1V/mS  
GENERAL SPECIFICATIONS  
MTBF  
Weight  
Io=80% of Io, max; Ta=25°C  
17  
M hours  
grams  
1.5  
DS_DCS12S0A0S06NFA_12072012  
2
CHARACTERISTICS CURVES  
The following figures provide Converter Efficiency versus output current  
Figure 1: Converter efficiency vs. output current (5.0Vout)  
Figure 2: Converter efficiency vs. output current (3.3 Vout)  
Figure 3: Converter efficiency vs. output current (2.5 Vout)  
Figure 4: Converter efficiency vs. output current (1.8Vout)  
DS_DCS12S0A0S06NFA_12072012  
3
Figure 5: Converter efficiency vs. output current (1.2Vout)  
Figure 6: Converter efficiency vs. output current (0.59Vout)  
The following figures provide typical output ripple and noise at 25oC  
Figure 7: Output ripple & noise at 12Vin, 5.0V/6A out  
Figure 8: Output ripple & noise at 12Vin, 3.3V/6A out  
CH1:VOUT, 20mV/div, 1uS/div  
CH1:VOUT, 20mV/div, 1uS/div  
DS_DCS12S0A0S06NFA_12072012  
4
Figure 9: Output ripple & noise at 12Vin, 2.5V/6A out  
Figure 10: Output ripple & noise at 12Vin, 1.8V/6A out  
CH1:VOUT, 20mV/div, 1uS/div  
CH1:VOUT, 20mV/div, 1uS/div  
Figure 11: Output ripple & noise at 12Vin, 1.2 V/6A out  
Figure 12: Output ripple & noise at 12Vin, 0.59 V/6A out  
CH1:VOUT, 20mV/div, 1uS/div  
CH1:VOUT, 20mV/div, 1uS/div  
DS_DCS12S0A0S06NFA_12072012  
5
The following figures provide typical start-up using input voltage at 25oC  
Figure 13: Turn on delay time at 12Vin, 5.0V/6A out  
Figure 14: Turn on delay time at 12Vin, 3.3V/6A out  
(Top trace : VOUT, 2V/div; Bottom trace: VIN, 5V/div; 2mS/div)  
(Top trace: VOUT, 1V/div; Bottom trace: VIN, 5V/div; 2mS/div)  
Figure 15: Turn on delay time at 12Vin, 2.5V/6A out  
Figure 16: Turn on delay time at 12Vin, 1.8V/6A out  
Top trace: VOUT, 1V/div; Bottom trace: VIN, 5V/div; 2mS/div)  
(Top trace : VOUT, 0.5V/div, Bottom trace: VIN, 5V/div; 2mS/div)  
DS_DCS12S0A0S06NFA_12072012  
6
Figure 17: Turn on delay time at 12Vin, 1.2V/6A out  
Figure 18: Turn on delay time at 12Vin, 0.59V/6A out  
(Top trace: VOUT, 0.5V/div; Bottom trace: VIN, 5V/div; 2mS/div)  
(Top trace: VOUT, 0.2V/div; Bottom trace: VIN, 5V/div; 2mS/div)  
The following figures provide transient response to dynamic load change at 25oC  
Figure 19: Typical transient response to step load change at  
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,  
5.0Vout (Cout = 1uF ceramic, 47uF+10μFceramic)  
CH1 : VOUT, 0.1V/div, 200uS/div  
Figure 20: Typical transient response to step load change at  
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,  
3.3Vout (Cout = 1uF ceramic, 47uF+10μFceramic)  
CH1 : VOUT, 0.1V/div, 200uS/div  
DS_DCS12S0A0S06NFA_12072012  
7
Figure 21: Typical transient response to step load change at  
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,  
2.5Vout (Cout = 1uF+ 47uF+10μF ceramic)  
Figure 22: Typical transient response to step load change at  
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,  
1.8Vout (Cout = 1uF+ 47uF+10μF ceramic)  
CH1 : VOUT, 0.1V/div, 200uS/div  
CH1 : VOUT, 0.1V/div,200uS/div  
Figure 23: Typical transient response to step load change at  
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,  
1.2Vout (Cout = 1uF+ 47uF+10μF ceramic)  
Figure 24: Typical transient response to step load change at  
1A/μS from 100%~ 50%~100% of Io, max at 12Vin,  
0.59Vout (Cout = 1uF+ 47uF+10μF ceramic)  
CH1 : VOUT, 0.1V/div, 200uS/div  
CH1 : VOUT, 0.1V/div, 200uS/div  
DS_DCS12S0A0S06NFA_12072012  
8
The following figures provide output short circuit current at 25oC  
Figure 25: Output short circuit current 12Vin, 5.0Vout  
Top trace: Vo, 1V/div; Bottom trace: Io, 5A/div; 20ms/div  
Figure 26: Output short circuit current 12Vin, 0.59 Vout  
Top trace: Vo, 1V/div ;Bottom trace: Io, 5A/div; 20ms/div  
The following figures provide output short circuit current at 25oC  
Figure 27:Tracking function, Vtracking=5.5 V, Vout= 5.0V, full load  
Top trace:Vtracking, 1V/div; Bottom trace: Vout,1 V/div;1ms/div  
Figure 28:Tracking function, Vtracking=0.8V,Vout= 0.59V, full load  
Top trace:Vtracking, 0.2V/div;Bottom trace: Vout,0.2 V/div; 1ms/div  
DS_DCS12S0A0S06NFA_12072012  
9
DESIGN CONSIDERATIONS  
TEST CONFIGURATIONS  
Input Source Impedance  
To maintain low noise and ripple at the input voltage, it is  
critical to use low ESR capacitors at the input to the  
module. A highly inductive source can affect the stability  
of the module. An input capacitance must be placed  
close to the modules input pins to filter ripple current and  
ensure module stability in the presence of inductive  
traces that supply the input voltage to the module.  
Figure 29: Input reflected-ripple test setup  
Vo  
Resistive  
Load  
1uF  
10uF  
tantalum ceramic  
SCOPE  
GND  
Note: Use a 10μF tantalum and 1μF capacitor. Scope  
measurement should be made using a BNC connector.  
Figure 30: Peak-peak output noise and startup transient  
measurement test setup.  
VI  
Vo  
GND  
Figure 31: Output voltage and efficiency measurement test  
setup  
Note: All measurements are taken at the module terminals.  
When the module is not soldered (via socket), place  
Kelvin connections at module terminals to avoid  
measurement errors due to contact resistance.  
Vo Io  
Vi Ii  
(  
)100 %  
DS_DCS12S0A0S06NFA_12072012  
10  
FEATURES DESCRIPTIONS  
DESIGN CONSIDERATIONS (CON.)  
Remote On/Off  
Safety Considerations  
The DCS series power modules have an On/Off pin for  
remote On/Off operation. Both positive and negative  
On/Off logic options are available in the DCS series power  
modules.  
For safety-agency approval the power module must be  
installed in compliance with the spacing and separation  
requirements of the end-use safety agency standards.  
For the converter output to be considered meeting the  
requirements of safety extra-low voltage (SELV), the  
input must meet SELV requirements. The power module  
has extra-low voltage (ELV) outputs when all inputs are  
ELV.  
For positive logic module, connect an open collector  
(NPN) transistor or open drain (N channel) MOSFET  
between the On/Off pin and the GND pin (see figure32).  
Positive logic On/Off signal turns the module ON during  
the logic high and turns the module OFF during the logic  
low. When the positive On/Off function is not used, leave  
the pin floating or tie to Vin (module will be On).  
The input to these units is to be provided with a  
maximum 10A fuse in the ungrounded lead.  
For negative logic module, the On/Off pin is pulled high  
with an external pull-up 5kΩ resistor (see figure 33).  
Negative logic On/Off signal turns the module OFF during  
logic high and turns the module ON during logic low. If the  
negative On/Off function is not used, leave the pin floating  
or tie to GND. (module will be on)  
Input Under voltage Lockout  
At input voltages below the input under voltage lockout  
limit, the module operation is disabled. The module will  
begin to operate at an input voltage above the under  
voltage lockout turn-on threshold.  
Vo  
Vin  
Over-Current Protection  
ION/OFF  
To provide protection in an output over load fault  
condition, the unit is equipped with internal over-current  
protection. When the over-current protection is  
triggered, the unit enters hiccup mode. The units  
operate normally once the fault condition is removed.  
On/Off  
RL  
Q1  
GND  
Figure 32: Positive remote On/Off implementation  
Vo  
Vin  
Rpull-  
up  
ION/OFF  
On/Off  
RL  
Q1  
GND  
Figure 33: Negative remote On/Off implementation  
DS_DCS12S0A0S06NFA_12072012  
11  
FEATURES DESCRIPTIONS (CON.)  
Vo  
Remote Sense  
RLoad  
TRIM  
Rtrim  
GND  
The DCS provide Vo remote sensing to achieve proper  
regulation at the load points and reduce effects of  
distribution losses on output line. In the event of an open  
remote sense line, the module shall maintain local sense  
regulation through an internal resistor. The module shall  
correct for a total of 0.5V of loss. The remote sense line  
impedance shall be < 10.  
Figure 35: Circuit configuration for programming output voltage  
using an external resistor  
Table 1 provides Rtrim values required for some common  
output voltages, By using a 0.5% tolerance trim resistor, set  
point tolerance of ±1.5% can be achieved as specified in  
the electrical specification.  
Distribution Losses  
Distribution Losses  
Vo  
Vin  
Sense  
Table 1  
RL  
Vo(V)  
0.590  
0.600  
1.000  
1.200  
1.500  
1.800  
2.500  
3.300  
5.000  
Rtrim(KΩ)  
Open  
GND  
656.700  
14.450  
9.704  
Distribution  
Distribution  
Figure 34: Effective circuit configuration for remote sense  
operation  
6.502  
Output Voltage Programming  
4.888  
3.096  
The output voltage of the DCS can be programmed to any  
voltage between 0.59Vdc and 5.0Vdc by connecting one  
resistor (shown as Rtrim in Figure 35) between the TRIM  
and GND pins of the module. Without this external  
resistor, the output voltage of the module is 0.59 Vdc. To  
calculate the value of the resistor Rtrim for a particular  
output voltage Vo, please use the following equation:  
2.182  
1.340  
Certain restrictions apply on the output voltage set point  
depending on the input voltage. These are shown in the  
Output Voltage vs. Input Voltage Set Point Area plot in  
Figure 36. The Upper Limit curve shows that for output  
voltages of 0.9V and lower, the input voltage must be lower  
than the maximum of 14V. The Lower Limit curve shows  
that for output voltages of 3.8V and higher, the input voltage  
needs to be larger than the minimum of 4.5V.  
5.91  
Rtrim   
K  
Vo 0.591  
Rtrim is the external resistor in kΩ  
Vo is the desired output voltage.  
For example, to program the output voltage of the DNS  
module to 5.0Vdc, Rtrim is calculated as follows:  
5.91  
Rtrim   
K1.34K  
5.0 0.591  
Figure 36: Output Voltage vs. Input Voltage Set Point Area plot  
showing limits where the output voltage can be set for different  
input voltages.  
DS_DCS12S0A0S06NFA_12072012  
12  
FEATURE DESCRIPTIONS (CON.)  
When an analog voltage is applied to the SEQ pin, the  
output voltage tracks this voltage until the output reaches  
the set-point voltage. The final value of the SEQ voltage  
must be set higher than the set-point voltage of the  
module. The output voltage follows the voltage on the  
SEQ pin on a one-to-one basis. By connecting multiple  
modules together, multiple modules can track their output  
voltages to the voltage applied on the SEQ pin.  
Voltage Margining  
Output voltage margining can be implemented in the DCS  
modules by connecting a resistor, R margin-up, from the Trim  
pin to the ground pin for margining-up the output voltage  
and by connecting a resistor, Rmargin-down, from the Trim pin  
to the output pin for margining-down. Figure 37 shows the  
circuit configuration for output voltage margining. If  
unused, leave the trim pin unconnected. A calculation tool  
is available from the evaluation procedure which  
computes the values of Rmargin-up and Rmargin-down for a  
specific output voltage and margin percentage.  
For proper voltage sequencing, first, input voltage is  
applied to the module. The On/Off pin of the module is  
left unconnected (or tied to GND for negative logic  
modules or tied to VIN for positive logic modules) so that  
the module is ON by default. After applying input voltage  
to the module, a minimum 10msec delay is required  
before applying voltage on the SEQ pin. This delay gives  
the module enough time to complete its internal power-up  
soft-start cycle. During the delay time, the SEQ pin  
should be held close to ground (nominally 50mV ± 20  
mV). This is required to keep the internal op-amp out of  
saturation thus preventing output overshoot during the  
start of the sequencing ramp. By selecting resistor R1  
(see Figure. 39) according to the following equation  
Vo  
Vin  
Rmargin-down  
Q1  
Trim  
GND  
On/Off  
Rmargin-up  
Q2  
Rtrim  
Figure 37: Circuit configuration for output voltage margining  
24950  
R1   
Vin 0.05  
Output Voltage Sequencing  
The DCS 12V 6A modules include a sequencing feature,  
EZ-SEQUENCE that enables users to implement various  
types of output voltage sequencing in their applications.  
This is accomplished via an additional sequencing pin.  
When not using the sequencing feature, either tie the SEQ  
pin to VIN or leave it unconnected.  
Figure 38: Sequential Start-up  
The voltage at the sequencing pin will be 50mV when  
the sequencing signal is at zero.  
DS_DCS12S0A0S06NFA_12072012  
13  
Power Good  
FEATURE DESCRIPTIONS (CON.)  
The DCS modules provide a Power Good (PGOOD)  
signal that is implemented with an open-drain output to  
indicate that the output voltage is within the regulation  
limits of the power module. The PGOOD signal will be  
de-asserted to a low state if any condition such as over  
temperature, over current or loss of regulation occurs that  
would result in the output voltage going ±10% outside the  
set point value. The PGOOD terminal should be  
connected through a pull up resistor (suggested value  
100KΩ) to a source of 5VDC or lower.  
After the 10msec delay, an analog voltage is applied to  
the SEQ pin and the output voltage of the module will  
track this voltage on a one-to-one volt bases until the  
output reaches the set-point voltage. To initiate  
simultaneous shutdown of the modules, the SEQ pin  
voltage is lowered in a controlled manner. The output  
voltage of the modules tracks the voltages below their  
set-point voltages on a one-to-one basis. A valid input  
voltage must be maintained until the tracking and output  
voltages reach ground potential.  
When using the EZ-SEQUENCETM feature to control  
start-up of the module, pre-bias immunity during startup is  
disabled. The pre-bias immunity feature of the module  
relies on the module being in the diode-mode during  
start-up. When using the EZ-SEQUENCETM feature,  
modules goes through an internal set-up time of 10msec,  
and will be in synchronous rectification mode when the  
voltage at the SEQ pin is applied. This will result in the  
module sinking current if a pre-bias voltage is present at  
the output of the module.  
Monotonic Start-up and Shutdown  
The DCS 6A modules have monotonic start-up and  
shutdown behavior for any combination of rated input  
voltage, output current and operating temperature range.  
Figure 39: Circuit showing connection of the sequencing signal to  
the SEQ pin.  
DS_DCS12S0A0S06NFA_12072012  
14  
THERMAL CURVES  
THERMAL CONSIDERATIONS  
Thermal management is an important part of the system  
design. To ensure proper, reliable operation, sufficient  
cooling of the power module is needed over the entire  
temperature range of the module. Convection cooling is  
usually the dominant mode of heat transfer.  
Hence, the choice of equipment to characterize the  
thermal performance of the power module is a wind  
tunnel.  
Thermal Testing Setup  
Delta’s DC/DC power modules are characterized in  
heated vertical wind tunnels that simulate the thermal  
environments encountered in most electronics  
equipment. This type of equipment commonly uses  
vertically mounted circuit cards in cabinet racks in which  
the power modules are mounted.  
Figure 41: Temperature measurement location  
The allowed maximum hot spot temperature is defined at 120  
DCS12S0A0S06OutputCurrentvs.AmbientTemperature and AirVelocity  
OutputCurrent(A)  
@Vin=12V Vout=5.0V (EitherOrientation)  
6
Natural  
Convection  
5
100LFM  
The following figure shows the wind tunnel  
characterization setup. The power module is mounted  
on a test PWB and is vertically positioned within the  
wind tunnel.  
4
200LFM  
300LFM  
3
400LFM  
2
1
0
500LFM  
PWB  
FANCING PWB  
600LFM  
MODULE  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
105  
AmbientTemperature ()  
Figure 42: Output current vs. ambient temperature and air  
velocity@Vin=12V, Vout=5.0V(Either Orientation)  
DCS12S0A0S06OutputCurrentvs.AmbientTemperature and AirVelocity  
AIR VELOCITY  
AND AMBIENT  
TEMPERATURE  
SURED BELOW  
THE MODULE  
OutputCurrent(A)  
@Vin = 12V Vout=3.3V(EitherOrientation)  
6
Natural  
Convection  
AIR FLOW  
5
100LFM  
200LFM  
300LFM  
4
3
2
1
0
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)  
Figure 40: Wind tunnel test setup  
400LFM  
500LFM  
600LFM  
Thermal Derating  
Heat can be removed by increasing airflow over the  
module. To enhance system reliability, the power  
module should always be operated below the maximum  
operating temperature. If the temperature exceeds the  
maximum module temperature, reliability of the unit may  
be affected.  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
105  
AmbientTemperature ()  
Figure 43: Output current vs. ambient temperature and air  
velocity@Vin=12V, Vout=3.3V(Either Orientation)  
DS_DCS12S0A0S06NFA_12072012  
15  
DCS12S0A0S06OutputCurrentvs.AmbientTemperature and AirVelocity  
@Vin = 12V Vout=2.5V(EitherOrientation)  
DCS12S0A0S06OutputCurrentvs.AmbientTemperature and AirVelocity  
@Vin = 12V Vout=0.59V(EitherOrientation)  
OutputCurrent(A)  
OutputCurrent(A)  
6
5
4
3
2
1
0
6
5
4
3
2
1
0
Natural  
Convection  
Natural  
Convection  
100LFM  
100LFM  
200LFM  
200LFM  
300LFM  
300LFM  
400LFM  
400LFM  
500LFM  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
105  
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
105  
AmbientTemperature ()  
AmbientTemperature ()  
Figure 44: Output current vs. ambient temperature and air  
Figure 47: Output current vs. ambient temperature and air  
velocity@Vin=12V, Vout=0.59 V(Either Orientation)  
velocity@Vin=12V, Vout=2.5V(Either Orientation)  
DCS12S0A0S06OutputCurrentvs.AmbientTemperature and AirVelocity  
OutputCurrent(A)  
@Vin = 12V Vout=1.8V(EitherOrientation)  
6
Natural  
Convection  
5
100LFM  
200LFM  
4
300LFM  
3
400LFM  
500LFM  
2
1
0
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
105  
AmbientTemperature ()  
Figure 45: Output current vs. ambient temperature and air  
velocity@Vin=12V, Vout=1.8V(Either Orientation)  
DCS12S0A0S06OutputCurrentvs.AmbientTemperature and AirVelocity  
OutputCurrent(A)  
@Vin = 12V Vout=1.2V(EitherOrientation)  
6
Natural  
Convection  
5
100LFM  
200LFM  
4
300LFM  
400LFM  
3
500LFM  
2
1
0
55  
60  
65  
70  
75  
80  
85  
90  
95  
100  
105  
AmbientTemperature ()  
Figure 46: Output current vs. ambient temperature and air  
velocity@Vin=12V, Vout=1.2V(Either Orientation)  
DS_DCS12S0A0S06NFA_12072012  
16  
PICK AND PLACE LOCATION  
RECOMMENDED PAD LAYOUT  
SURFACE-MOUNT TAPE & REEL  
DS_DCS12S0A0S06NFA_12072012  
17  
LEAD (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE  
Note: The temperature refers to the pin of DCS, measured on the pin Vout joint.  
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE  
Temp.  
Peak Temp. 240 ~ 245  
220  
200℃  
Ramp down  
max. 4/sec.  
Preheat time  
90~120 sec.  
150℃  
25℃  
Time Limited 75 sec.  
above 220℃  
Ramp up  
max. 3/sec.  
Time  
Note: The temperature refers to the pin of DCS, measured on the pin Vout joint.  
DS_DCS12S0A0S06NFA_12072012  
18  
MECHANICAL DRAWING  
DS_DCS12S0A0S06NFA_12072012  
19  
PART NUMBERING SYSTEM  
DCS  
12  
S
0A0  
S
06  
N
F
A
On/Off  
logic  
Product  
Series  
Numbers of  
Outputs  
Output  
Voltage  
Package  
Type  
Output  
Current  
Input Voltage  
Option Code  
DCT- 3A  
DCS - 6A  
DCM - 12A  
DCL - 20A  
04 - 2.4~5.5V  
S - Single  
0A0 -  
S - SMD  
03- 3A  
N- negative  
P- positive  
F- RoHS 6/6  
(Lead Free)  
A - Standard Function  
12 4.5~14V  
Programmable  
06 - 6A  
12 - 12A  
20 - 20A  
MODEL LIST  
Model Name  
Efficiency  
12Vin, 5Vdc @ 6A  
Packaging  
Input Voltage  
Output Voltage Output Current  
DCS12S0A0S06NFA  
SMD  
4.5 ~ 14Vdc  
0.59V~ 5.0Vdc  
6A  
94. 3%  
CONTACT: www.deltaww.com/dcdc  
USA:  
Telephone:  
East Coast: (888) 335 8201  
West Coast: (888) 335 8208  
Fax: (978) 656 3964  
Email: DCDC@delta-corp.com  
Europe:  
Telephone: +31-20-655-0967  
Fax: +31-20-655-0999  
Asia & the rest of world:  
Telephone: +886 3 4526107  
Ext. 6220~6224  
Fax: +886 3 4513485  
Email: DCDC@delta.com.tw  
Email: DCDC@delta-es.tw  
WARRANTY  
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon  
request from Delta.  
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta  
for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license  
is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these  
specifications at any time, without notice.  
DS_DCS12S0A0S06NFA_12072012  
20  

相关型号:

DCT0603-2005%PW180K

RES,SMT,THICK FILM,180K OHMS,50WV,5% +/-TOL,-200,200PPM TC,0603 CASE
VISHAY

DCT0603-2005%PW270K

RES,SMT,THICK FILM,270K OHMS,50WV,5% +/-TOL,-200,200PPM TC,0603 CASE
VISHAY

DCT0603-2005%PW330K

RES,SMT,THICK FILM,330K OHMS,50WV,5% +/-TOL,-200,200PPM TC,0603 CASE
VISHAY

DCT0603-2005%PW390K

RES,SMT,THICK FILM,390K OHMS,50WV,5% +/-TOL,-200,200PPM TC,0603 CASE
VISHAY

DCT0603-2005%PW470K

RES,SMT,THICK FILM,470K OHMS,50WV,5% +/-TOL,-200,200PPM TC,0603 CASE
VISHAY

DCT0603-2005%PW560K

RES,SMT,THICK FILM,560K OHMS,50WV,5% +/-TOL,-200,200PPM TC,0603 CASE
VISHAY

DCT0603-2005%PW680K

RES,SMT,THICK FILM,680K OHMS,50WV,5% +/-TOL,-200,200PPM TC,0603 CASE
VISHAY

DCT0603-2005%PW820K

RES,SMT,THICK FILM,820K OHMS,50WV,5% +/-TOL,-200,200PPM TC,0603 CASE
VISHAY

DCT104803P

SWITCHING REGULATOR, 440kHz SWITCHING FREQ-MAX, PDIP22, PLASTIC, DIP-28
TI

DCT104803P-U

IC SWITCHING REGULATOR, 440 kHz SWITCHING FREQ-MAX, PDSO22, PLASTIC, DIP-28, Switching Regulator or Controller
TI

DCT104805P

SWITCHING REGULATOR, 440kHz SWITCHING FREQ-MAX, PDIP22, PLASTIC, DIP-28
TI

DCT104805P-U

SWITCHING REGULATOR, 440kHz SWITCHING FREQ-MAX, PDSO22, PLASTIC, DIP-28
TI