PJ-12V50WBNA [DELTA]
PJ Open Frame Power Supply;型号: | PJ-12V50WBNA |
厂家: | DELTA ELECTRONICS, INC. |
描述: | PJ Open Frame Power Supply |
文件: | 总12页 (文件大小:1007K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
PJ
Highlights & Features
–
–
–
–
–
Universal AC input voltage range (85Vac – 264Vac)
Low Inrush Current / Low Leakage Current
High efficiency and PF factor to conserve energy
Conforms to harmonic current IEC/EN 61000-3-2, Class A
Conformal coating on PCBA to protect against chemical and
dust pollutants
–
–
Versatile configuration options: Open Frame, L Frame,
Enclosed
Long life capacitors
Safety Standards
CB Certified for worldwide use
Model Number:
PJ-12V50W□NA
Unit Weight:
0.16 kg (Open Frame)
0.28 kg (Enclosed)
Dimensions (L x W x D): 132 x 50 x 26.6 mm (Open Frame)
162 x 60 x 36 mm (Enclosed)
General Description
The PJ series of Open Frame Power Supply comes with universal AC input at 85Vac to 264Vac. Other features include low leakage /
Inrush current and conformal coating on the PCBAs to provide protection against dust and chemical pollutants. The built-in active PFC
provides PF > 0.97 and fulfills Harmonic Current Emission according to IEC/EN 61000-3-2. The PJ series is certified for EMC
standards according to EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment and EN 55022 for Industrial
Technology Equipment (ITE) radio-frequency equipment and EMS according to EN 55024. In addition, the detachable input and output
connectors are from JST and only recognized Japanese capacitors are used.
Metal chassis and case cover are available as options for different installation preferences. The PJ series conforms to major
international safety standards according to EN/UL 60950-1 standards and are fully compliant with RoHS Directive 2011/65/EU for
environmental protection.
Model Information
PJ Open Frame Power Supply
Model Number
Input Voltage Range
Output
Voltage
Output Current
PJ-12V50W□NA
85-264Vac
12Vdc
4.30A
Model Numbering
CC Code
PJ –
12V
50W
□
N
A
PJ Series
Output Voltage Output Power Product Type
Remote ON/OFF Function Delta Standard
N - No Remote ON/OFF
B - Open Frame
L - L Frame
C - Enclosed
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
1
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
Specifications
Input Ratings / Characteristics
Nominal Input Voltage
Input Voltage Range
Nominal Input Frequency
Input Frequency Range
Input Current
100-240Vac
85-264Vac
50-60Hz
47-63Hz
0.65A typ. @ 100Vac, 0.35A typ. @ 200Vac
83.0% typ. @ 100Vac, 85.0% typ. @ 200Vac
15A typ. @ 100Vac, 30A typ. @ 200Vac
Yes, 0.98 typ. @ 100Vac, 0.97 typ. @ 200Vac
0.1mA @ 100Vac, 0.2mA @ 230Vac
Efficiency at 100% Load
Max Inrush Current
Power Factor Correction
Leakage Current
Output Ratings / Characteristics
Nominal Output Voltage
Output Voltage Tolerance
Output Voltage Adjustment Range
Output Current
12Vdc
± 1% (initial set point tolerance from factory)
10.8-13.2Vdc
4.30A
Output Power
51.6W
Line Regulation
< 48mV
Load Regulation
< 100mV
Ripple (20MHz)
< 120mVpp @ 0°C to 50°C, < 160mVpp @ -10°C to 0°C
< 150mVpp @ 0°C to 50°C, < 180mVpp @ -10°C to 0°C
500ms typ. @ 100Vac
Ripple Noise (20MHz)
Start-up Time
Hold-up Time
20ms typ. @ 100Vac
Dynamic Response (Overshoot & Undershoot O/P Voltage)
Start-up with Capacitive Loads
± 5% @ 0-50% load and 50-100% load
8,000µF Max
Mechanical
Case Chassis
Case Cover
Dimensions
SGCC
SGCC
132 x 50 x 26.6 mm (Open Frame)
162 x 60 x 36 mm (Enclosed)
Unit Weight
0.16 kg (Open Frame)
0.28 kg (Enclosed)
NA
Indicator
Cooling System
Terminal
Convection
Input JST B3P5-VH (LF)(SN)
Output JST B4P-VH (LF)(SN)
AWG 22-18
Wire
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
2
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
Environment
Surrounding Air Temperature
Power De-rating
Operating -10°C to +70°C
Storage -25°C to +75°C
Mounting Orientation A > 50°C de-rate power by 2.5% / °C
< 90Vac de-rate power by 2% / V
Operating Humidity
20-90% RH (Non-Condensing)
3,000 Meters
Operating Altitude
Shock Test (Non-Operating)
IEC60068-2-27, 196.1m/S² (20G),11ms, once along X,
Y, and Z axis
Vibration (Operating)
Protections
IEC60068-2-6, 10Hz to 55Hz @ 19.6m/S² (2G); 3 min
period, 60 min per axis for all X, Y, Z direction
Overvoltage
13.8-16.8V, Latch Mode
Overload / Overcurrent
> 105% of rated load current, Hicc-up Mode,
Non-Latching (Auto-Recovery)
Latch Mode
Over Temperature
Short Circuit
Hicc-up Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Class I with PE* connection
Protection Against Shock
*PE: Primary Earth
Reliability Data
MTBF
> 200,000 hrs. as per JEITA RCR-9102B
10 years (115Vac, 50% load @ 40°C)
Expected Cap Life Time
Safety Standards / Directives
Electrical Safety
TUV Bauart to EN60950-1, UL/cUL recognized to
UL60950-1 and CSA C22.2 No. 60950-1, CB scheme to
IEC60950-1
ITE
CE
IEC60950-1
In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
Material and Parts
Galvanic Isolation
RoHS Directive 2011/65/EU Compliant
Input to Output 3.0KVac
Input to Ground 2.0KVac
Output to Ground 0.5KVac
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
3
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
EMC
EMC / Emissions
Immunity to
CISPR22, EN55022, FCC Title 47: Class B
Electrostatic Discharge
IEC 61000-4-2 Level 4 Criteria A1)
Air Discharge: 15kV
Contact Discharge: 8kV
Radiated Field
IEC 61000-4-3 Level 3 Criteria A1)
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation
Electrical Fast Transient / Burst
Surge
IEC 61000-4-4 Level 3 Criteria A1)
2kV
IEC 61000-4-5 Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 1kV
Conducted
IEC 61000-4-6 Level 3 Criteria A1)
150kHz-80MHz, 10Vrms
Power Frequency Magnetic Fields
Voltage Dips
IEC 61000-4-8 Criteria A1)
Magnetic field strength 30A/Meter
IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable
Low Energy Pulse Test (Ring Wave)
IEC 61000-4-12 Level 3 Criteria A1)
Common Mode2): 2kV
Differential Mode3): 1kV
Harmonic Current Emission
IEC/EN 61000-3-2, Class A
IEC/EN 61000-3-3
Voltage Fluctuation and Flicker
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)
Block Diagram
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
4
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
Dimensions
L x W x D: 132 x 50 x 26.6 mm (Open Frame)
L x W x D: 162 x 60 x 36 mm (L Frame)
Item Device Description
Notes
1
2
3
4
Input Connector
Output Connector
VR
–
–
Dimensions are in mm
For information on Mounting Torque, and I/O Connector and Housing, please refer
to Table 1 (Page 6).
For L Frame type: There are 6 threaded mounting holes and 5 normal mounting
holes.
For Open Frame type: There are 4 normal mounting holes.
–
–
Chassis
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
5
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
L x W x D: 162 x 60 x 36 mm (Enclosed)
Notes
Item Device Description
1
2
3
4
5
Input Connector
Output Connector
VR
–
–
Dimensions are in mm
For information on Mounting Torque, and I/O Connector and Housing, please refer
to Table 1 (Page 6).
For Enclosed type: There are 6 threaded mounting holes and 5 normal mounting
holes.
–
Cover
Chassis
Assembly & Installation
Assembly Reference
■ Open Frame
■ L Frame / Enclosed
For safety reasons, please ensure the mounted device is kept at ≥ 4mm safety distance at all sides from other components and
equipments. Please insert an insulation sheet between the system and product, if the safety distance is less than 4mm.
Use flexible cable (stranded or solid) of AWG No. 22-18. Please refer to Table 1 for the recommended Housing and Terminal.
Table 1
Connector (Board Mounting)
B3P5-VH(LF)(SN)
Housing
VHR-5N
VHR-4N
Terminal
Input (JST)
Output (JST)
SVH-21T-P1.1
B4P-VH(LF)(SN)
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
6
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
Mounting Orientation
–
–
–
Any excessive twisting or bending
may damage the device’s PCB.
Please handle the device with care.
The device is not recommended to
be placed on low thermal conductive
surfaces. For example, plastics.
Prevent any foreign metal, particles
or conductors from entering the
device through the openings during
installation. It may cause: -Electric
shock; Safety hazard; Product
failure.
–
The power supply must be
mounted by metal screws onto a
grounded metal surface. It is
highly recommended that the
Earth terminal on the connector
be connected to the grounded
metal surface.
Engineering Data
Convection
■ Open Frame / L Frame
■ Enclosed
Fig.1.1 De-rating for Mounting Orientation A to F
> 50°C de-rate power by 2.5% / °C
Fig.1.2 De-rating for Mounting Orientation A to F
> 40°C de-rate power by 2.5% / °C
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
7
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
Forced Cooling (Air Velocity > 0.7m/s)
■ Air Flow Direction
■ Open Frame / L Frame
■ Enclosed
Fig.1.3 De-rating for Mounting Orientation A to F
> 60°C de-rate power by 2% / °C
Fig.1.4 De-rating for Mounting Orientation A to F
> 50°C de-rate power by 2% / °C
Notes
1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region,
refer to the graphs shown above.
2. If the output capacity is not reduced when the surrounding air temperature is more than the upper limit temperature, the device will
run into Over Temperature Protection. When activated, the output voltage will go into latch mode until the mains is reapplied and
the surrounding air temperature drops to its normal operating temperature.
3. Depending on the surrounding air temperature and output load delivered by the power supply, the device housing can be very hot!
4. If the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details.
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
8
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
Output De-rating VS. Input Voltage
■ No output power de-rating for the input voltage
range from 90Vac to 264Vac
Functions
Start-up Time
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its set value.
Hold-up Time
Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 95% of its set value, after the input voltage is removed.
■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
9
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
Dynamic Response
The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load from 0 to 50% and
50 to 100% of its rated current.
■ 0 to 50% Load
■ 50 to 100% Load
Inrush Current
Overload & Overcurrent Protections
Inrush current is the peak, instantaneous, input current measured
and, occurs when the input voltage is first applied. For AC input
voltages, the maximum peak value of inrush current will occur
during the first half cycle of the applied AC voltage. This peak
value decreases exponentially during subsequent cycles of AC
voltage.
The power supply’s Overload (OLP) and Overcurrent (OCP)
Protections will be activated when output current exceeds 105%
of IO (Max load). In such occurrence, the VO will start to droop and
once the power supply has reached its maximum power limit, the
protection is activated and the power supply will go into “Hiccup
mode” (Auto-Recovery). The power supply will recover once the
fault condition of the OLP and OCP is removed and IO is back
within the specifications.
Additionally, if the IO is <105% but >100% for a prolong period of
time (depending on the load), the Over Temperature Protection
(OTP) will be activated due to high temperature on critical
components. The power supply will then go into latch mode until
the fault is removed and the mains is reapplied.
Overvoltage Protection
The power supply’s overvoltage circuit will be activated when its
internal feedback circuit fails. The output voltage shall not exceed
its specifications defined on Page 3 under “Protections”.
Over Temperature Protection
As mentioned above, the power supply also has Over
Temperature Protection (OTP). This is activated when the
overload condition persists for an extended duration and the
output current is below the overload trigger point but >100% load.
In the event of a higher operating condition at 100% load, the
power supply will run into OTP when the surrounding air
temperature is higher than the operating temperature. When
activated, the output voltage will go into latch mode until the
mains is reapplied and the surrounding air temperature drops to
its normal operating temperature.
The power supply should be latch.
Short Circuit Protection
The power supply’s output OLP/OCP function also provides
protection against short circuits. When a short circuit is applied,
the output current will operate in “Hiccup mode”, as shown in the
illustration in the OLP/OCP section on this page. The power
supply will return to normal operation after the short circuit is
removed.
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
10
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 50W 1 Phase / PJ-12V50W□NA
Others
Delta RoHS Compliant
Restriction of the usage of hazardous substances
The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead,
mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and
electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in
electrical and electronic equipment”.
This product conforms to this standard.
Conformal Coating
The Protective Coating Technology
Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including
under device, and prevents leakage. The conformal coating dipping can be applied to PCBs or circuit board.
The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants
such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem
especially in highly conversing atmosphere.
All parameters are specified at 25°C ambient unless otherwise noted.
www.DeltaPSU.com (May 2013, Rev. 01)
11
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Delta:
PJ-12V50WCNA PJ-12V50WBNA
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明