PJ-12V50WBNA [DELTA]

PJ Open Frame Power Supply;
PJ-12V50WBNA
型号: PJ-12V50WBNA
厂家: DELTA ELECTRONICS, INC.    DELTA ELECTRONICS, INC.
描述:

PJ Open Frame Power Supply

文件: 总12页 (文件大小:1007K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
PJ  
Highlights & Features  
Universal AC input voltage range (85Vac – 264Vac)  
Low Inrush Current / Low Leakage Current  
High efficiency and PF factor to conserve energy  
Conforms to harmonic current IEC/EN 61000-3-2, Class A  
Conformal coating on PCBA to protect against chemical and  
dust pollutants  
Versatile configuration options: Open Frame, L Frame,  
Enclosed  
Long life capacitors  
Safety Standards  
CB Certified for worldwide use  
Model Number:  
PJ-12V50WNA  
Unit Weight:  
0.16 kg (Open Frame)  
0.28 kg (Enclosed)  
Dimensions (L x W x D): 132 x 50 x 26.6 mm (Open Frame)  
162 x 60 x 36 mm (Enclosed)  
General Description  
The PJ series of Open Frame Power Supply comes with universal AC input at 85Vac to 264Vac. Other features include low leakage /  
Inrush current and conformal coating on the PCBAs to provide protection against dust and chemical pollutants. The built-in active PFC  
provides PF > 0.97 and fulfills Harmonic Current Emission according to IEC/EN 61000-3-2. The PJ series is certified for EMC  
standards according to EN 55011 for industrial, scientific and medical (ISM) radio-frequency equipment and EN 55022 for Industrial  
Technology Equipment (ITE) radio-frequency equipment and EMS according to EN 55024. In addition, the detachable input and output  
connectors are from JST and only recognized Japanese capacitors are used.  
Metal chassis and case cover are available as options for different installation preferences. The PJ series conforms to major  
international safety standards according to EN/UL 60950-1 standards and are fully compliant with RoHS Directive 2011/65/EU for  
environmental protection.  
Model Information  
PJ Open Frame Power Supply  
Model Number  
Input Voltage Range  
Output  
Voltage  
Output Current  
PJ-12V50WNA  
85-264Vac  
12Vdc  
4.30A  
Model Numbering  
CC Code  
PJ –  
12V  
50W  
N
A
PJ Series  
Output Voltage Output Power Product Type  
Remote ON/OFF Function Delta Standard  
N - No Remote ON/OFF  
B - Open Frame  
L - L Frame  
C - Enclosed  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
1
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
Specifications  
Input Ratings / Characteristics  
Nominal Input Voltage  
Input Voltage Range  
Nominal Input Frequency  
Input Frequency Range  
Input Current  
100-240Vac  
85-264Vac  
50-60Hz  
47-63Hz  
0.65A typ. @ 100Vac, 0.35A typ. @ 200Vac  
83.0% typ. @ 100Vac, 85.0% typ. @ 200Vac  
15A typ. @ 100Vac, 30A typ. @ 200Vac  
Yes, 0.98 typ. @ 100Vac, 0.97 typ. @ 200Vac  
0.1mA @ 100Vac, 0.2mA @ 230Vac  
Efficiency at 100% Load  
Max Inrush Current  
Power Factor Correction  
Leakage Current  
Output Ratings / Characteristics  
Nominal Output Voltage  
Output Voltage Tolerance  
Output Voltage Adjustment Range  
Output Current  
12Vdc  
± 1% (initial set point tolerance from factory)  
10.8-13.2Vdc  
4.30A  
Output Power  
51.6W  
Line Regulation  
< 48mV  
Load Regulation  
< 100mV  
Ripple (20MHz)  
< 120mVpp @ 0°C to 50°C, < 160mVpp @ -10°C to 0°C  
< 150mVpp @ 0°C to 50°C, < 180mVpp @ -10°C to 0°C  
500ms typ. @ 100Vac  
Ripple Noise (20MHz)  
Start-up Time  
Hold-up Time  
20ms typ. @ 100Vac  
Dynamic Response (Overshoot & Undershoot O/P Voltage)  
Start-up with Capacitive Loads  
± 5% @ 0-50% load and 50-100% load  
8,000µF Max  
Mechanical  
Case Chassis  
Case Cover  
Dimensions  
SGCC  
SGCC  
132 x 50 x 26.6 mm (Open Frame)  
162 x 60 x 36 mm (Enclosed)  
Unit Weight  
0.16 kg (Open Frame)  
0.28 kg (Enclosed)  
NA  
Indicator  
Cooling System  
Terminal  
Convection  
Input JST B3P5-VH (LF)(SN)  
Output JST B4P-VH (LF)(SN)  
AWG 22-18  
Wire  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
2
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
Environment  
Surrounding Air Temperature  
Power De-rating  
Operating -10°C to +70°C  
Storage -25°C to +75°C  
Mounting Orientation A > 50°C de-rate power by 2.5% / °C  
< 90Vac de-rate power by 2% / V  
Operating Humidity  
20-90% RH (Non-Condensing)  
3,000 Meters  
Operating Altitude  
Shock Test (Non-Operating)  
IEC60068-2-27, 196.1m/S² (20G),11ms, once along X,  
Y, and Z axis  
Vibration (Operating)  
Protections  
IEC60068-2-6, 10Hz to 55Hz @ 19.6m/S² (2G); 3 min  
period, 60 min per axis for all X, Y, Z direction  
Overvoltage  
13.8-16.8V, Latch Mode  
Overload / Overcurrent  
> 105% of rated load current, Hicc-up Mode,  
Non-Latching (Auto-Recovery)  
Latch Mode  
Over Temperature  
Short Circuit  
Hicc-up Mode, Non-Latching  
(Auto-Recovery when the fault is removed)  
Class I with PE* connection  
Protection Against Shock  
*PE: Primary Earth  
Reliability Data  
MTBF  
> 200,000 hrs. as per JEITA RCR-9102B  
10 years (115Vac, 50% load @ 40°C)  
Expected Cap Life Time  
Safety Standards / Directives  
Electrical Safety  
TUV Bauart to EN60950-1, UL/cUL recognized to  
UL60950-1 and CSA C22.2 No. 60950-1, CB scheme to  
IEC60950-1  
ITE  
CE  
IEC60950-1  
In conformance with EMC Directive 2004/108/EC and  
Low Voltage Directive 2006/95/EC  
Material and Parts  
Galvanic Isolation  
RoHS Directive 2011/65/EU Compliant  
Input to Output 3.0KVac  
Input to Ground 2.0KVac  
Output to Ground 0.5KVac  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
3
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
EMC  
EMC / Emissions  
Immunity to  
CISPR22, EN55022, FCC Title 47: Class B  
Electrostatic Discharge  
IEC 61000-4-2 Level 4 Criteria A1)  
Air Discharge: 15kV  
Contact Discharge: 8kV  
Radiated Field  
IEC 61000-4-3 Level 3 Criteria A1)  
80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation  
Electrical Fast Transient / Burst  
Surge  
IEC 61000-4-4 Level 3 Criteria A1)  
2kV  
IEC 61000-4-5 Level 3 Criteria A1)  
Common Mode2): 2kV  
Differential Mode3): 1kV  
Conducted  
IEC 61000-4-6 Level 3 Criteria A1)  
150kHz-80MHz, 10Vrms  
Power Frequency Magnetic Fields  
Voltage Dips  
IEC 61000-4-8 Criteria A1)  
Magnetic field strength 30A/Meter  
IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable  
Low Energy Pulse Test (Ring Wave)  
IEC 61000-4-12 Level 3 Criteria A1)  
Common Mode2): 2kV  
Differential Mode3): 1kV  
Harmonic Current Emission  
IEC/EN 61000-3-2, Class A  
IEC/EN 61000-3-3  
Voltage Fluctuation and Flicker  
1) Criteria A: Normal performance within the specification limits  
2) Asymmetrical: Common mode (Line to earth)  
3) Symmetrical: Differential mode (Line to line)  
Block Diagram  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
4
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
Dimensions  
L x W x D: 132 x 50 x 26.6 mm (Open Frame)  
L x W x D: 162 x 60 x 36 mm (L Frame)  
Item Device Description  
Notes  
1
2
3
4
Input Connector  
Output Connector  
VR  
Dimensions are in mm  
For information on Mounting Torque, and I/O Connector and Housing, please refer  
to Table 1 (Page 6).  
For L Frame type: There are 6 threaded mounting holes and 5 normal mounting  
holes.  
For Open Frame type: There are 4 normal mounting holes.  
Chassis  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
5
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
L x W x D: 162 x 60 x 36 mm (Enclosed)  
Notes  
Item Device Description  
1
2
3
4
5
Input Connector  
Output Connector  
VR  
Dimensions are in mm  
For information on Mounting Torque, and I/O Connector and Housing, please refer  
to Table 1 (Page 6).  
For Enclosed type: There are 6 threaded mounting holes and 5 normal mounting  
holes.  
Cover  
Chassis  
Assembly & Installation  
Assembly Reference  
Open Frame  
L Frame / Enclosed  
For safety reasons, please ensure the mounted device is kept at 4mm safety distance at all sides from other components and  
equipments. Please insert an insulation sheet between the system and product, if the safety distance is less than 4mm.  
Use flexible cable (stranded or solid) of AWG No. 22-18. Please refer to Table 1 for the recommended Housing and Terminal.  
Table 1  
Connector (Board Mounting)  
B3P5-VH(LF)(SN)  
Housing  
VHR-5N  
VHR-4N  
Terminal  
Input (JST)  
Output (JST)  
SVH-21T-P1.1  
B4P-VH(LF)(SN)  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
6
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
Mounting Orientation  
Any excessive twisting or bending  
may damage the device’s PCB.  
Please handle the device with care.  
The device is not recommended to  
be placed on low thermal conductive  
surfaces. For example, plastics.  
Prevent any foreign metal, particles  
or conductors from entering the  
device through the openings during  
installation. It may cause: -Electric  
shock; Safety hazard; Product  
failure.  
The power supply must be  
mounted by metal screws onto a  
grounded metal surface. It is  
highly recommended that the  
Earth terminal on the connector  
be connected to the grounded  
metal surface.  
Engineering Data  
Convection  
Open Frame / L Frame  
Enclosed  
Fig.1.1 De-rating for Mounting Orientation A to F  
> 50°C de-rate power by 2.5% / °C  
Fig.1.2 De-rating for Mounting Orientation A to F  
> 40°C de-rate power by 2.5% / °C  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
7
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
Forced Cooling (Air Velocity > 0.7m/s)  
Air Flow Direction  
Open Frame / L Frame  
Enclosed  
Fig.1.3 De-rating for Mounting Orientation A to F  
> 60°C de-rate power by 2% / °C  
Fig.1.4 De-rating for Mounting Orientation A to F  
> 50°C de-rate power by 2% / °C  
Notes  
1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region,  
refer to the graphs shown above.  
2. If the output capacity is not reduced when the surrounding air temperature is more than the upper limit temperature, the device will  
run into Over Temperature Protection. When activated, the output voltage will go into latch mode until the mains is reapplied and  
the surrounding air temperature drops to its normal operating temperature.  
3. Depending on the surrounding air temperature and output load delivered by the power supply, the device housing can be very hot!  
4. If the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details.  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
8
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
Output De-rating VS. Input Voltage  
No output power de-rating for the input voltage  
range from 90Vac to 264Vac  
Functions  
Start-up Time  
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.  
Rise Time  
The time required for the output voltage to change from 10% to 90% of its set value.  
Hold-up Time  
Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time  
required for the output to reach 95% of its set value, after the input voltage is removed.  
Graph illustrating the Start-up Time, Rise Time, and Hold-up Time  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
9
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
Dynamic Response  
The power supply output voltage will remain within ±5% of its steady state value, when subjected to a dynamic load from 0 to 50% and  
50 to 100% of its rated current.  
0 to 50% Load  
50 to 100% Load  
Inrush Current  
Overload & Overcurrent Protections  
Inrush current is the peak, instantaneous, input current measured  
and, occurs when the input voltage is first applied. For AC input  
voltages, the maximum peak value of inrush current will occur  
during the first half cycle of the applied AC voltage. This peak  
value decreases exponentially during subsequent cycles of AC  
voltage.  
The power supply’s Overload (OLP) and Overcurrent (OCP)  
Protections will be activated when output current exceeds 105%  
of IO (Max load). In such occurrence, the VO will start to droop and  
once the power supply has reached its maximum power limit, the  
protection is activated and the power supply will go into “Hiccup  
mode” (Auto-Recovery). The power supply will recover once the  
fault condition of the OLP and OCP is removed and IO is back  
within the specifications.  
Additionally, if the IO is <105% but >100% for a prolong period of  
time (depending on the load), the Over Temperature Protection  
(OTP) will be activated due to high temperature on critical  
components. The power supply will then go into latch mode until  
the fault is removed and the mains is reapplied.  
Overvoltage Protection  
The power supply’s overvoltage circuit will be activated when its  
internal feedback circuit fails. The output voltage shall not exceed  
its specifications defined on Page 3 under “Protections”.  
Over Temperature Protection  
As mentioned above, the power supply also has Over  
Temperature Protection (OTP). This is activated when the  
overload condition persists for an extended duration and the  
output current is below the overload trigger point but >100% load.  
In the event of a higher operating condition at 100% load, the  
power supply will run into OTP when the surrounding air  
temperature is higher than the operating temperature. When  
activated, the output voltage will go into latch mode until the  
mains is reapplied and the surrounding air temperature drops to  
its normal operating temperature.  
The power supply should be latch.  
Short Circuit Protection  
The power supply’s output OLP/OCP function also provides  
protection against short circuits. When a short circuit is applied,  
the output current will operate in “Hiccup mode”, as shown in the  
illustration in the OLP/OCP section on this page. The power  
supply will return to normal operation after the short circuit is  
removed.  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
10  
TECHNICAL DATASHEET  
PJ Open Frame Power Supply  
12V 50W 1 Phase / PJ-12V50WNA  
Others  
Delta RoHS Compliant  
Restriction of the usage of hazardous substances  
The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead,  
mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and  
electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in  
electrical and electronic equipment”.  
This product conforms to this standard.  
Conformal Coating  
The Protective Coating Technology  
Delta Electronics Group has designed the perfect dipping technique which penetrates everywhere including  
under device, and prevents leakage. The conformal coating dipping can be applied to PCBs or circuit board.  
The coating preserves the performance of precision electronic primarily by preventing ionizable contaminants  
such as salt from reaching circuit nodes, where the material slumps around sharp edges. This can be a problem  
especially in highly conversing atmosphere.  
All parameters are specified at 25°C ambient unless otherwise noted.  
www.DeltaPSU.com (May 2013, Rev. 01)  
11  
Mouser Electronics  
Authorized Distributor  
Click to View Pricing, Inventory, Delivery & Lifecycle Information:  
Delta:  
PJ-12V50WCNA PJ-12V50WBNA  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY