PMC24V150W1AA [DELTA]

24V 75W 1 Phase; 24V 75W 1期
PMC24V150W1AA
型号: PMC24V150W1AA
厂家: DELTA ELECTRONICS, INC.    DELTA ELECTRONICS, INC.
描述:

24V 75W 1 Phase
24V 75W 1期

文件: 总13页 (文件大小:715K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
24V 75W 1 Phase  
Features:  
Full aluminium casing for  
lightweight and corrosion  
resistant handling  
Ease of wire connection to  
Terminals  
Universal AC input  
Overload protection  
Over voltage protection  
Thermal protection  
MTBF:>700,000hrs  
Efficiency> 86%typ.  
Expected life time:10 years  
2 year warranty  
RoHS compliant  
PMC-24V075W1AA  
Summary  
The new Panel Mount Power Supply is the latest  
offering from one of the world’s largest power supply  
manufacturers and solution providers - Delta.  
Delta’s Panel Mount Power Supply also offers  
overvoltage and overload protection. Using a wide  
input voltage range design, it is compatible  
worldwide. The input also includes DC operating  
voltage from 100-375Vdc. Best of all, this excellent  
design and quality does not come with a big price  
tag.  
The product range offers a nominal output voltage of  
24V, a wide temperature range from -10°C to +70°C  
and a highly dependable minimum holdup time.  
The state-of-the-art design is made to withstand  
harsh industrial environments. What makes the  
product stands out from the crowd is its lightweight  
full aluminum body design which can withstand shock  
and vibration according to IEC60068-2.  
1/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Technical Data  
PMC-24V075W1AA  
1.) Input Data  
Nominal AC Input Voltage  
Input Voltage range  
100 - 240VAC  
85 - 264VAC  
Nominal AC Input Frequency  
AC Input Frequency  
50Hz  
47 - 63Hz  
DC Input Voltage Range  
120 – 375VDC  
Max. Input Current  
Efficiency  
1.8A Max.(1.5A @ 115VAC, 1.0A @ 230VAC)  
> 86% @ 230VAC & 115VAC  
< 40A @ 115VAC, < 80A @ 230VAC  
< 1.0mA @ 240VAC  
VARISTOR  
Max. Inrush current limitation.(Cold Start)  
Leakage Current  
Transient surge voltage protection  
Input fuse, internal (device protection)  
Recommended backup fuse: Power circuit-breaker characteristic  
T 3.15 AH / 250V  
6A ,10A,16A : B  
2.) Output Data  
Max. Output Power  
75W  
Nominal Output Voltage  
24 VDC  
Tolerance  
Output Voltage Adjust Range  
Nominal Output Current  
+/- 2% (Initial Set Point tolerance)  
22 – 28 VDC  
3.125 A  
Line Regulation  
Load Regulation  
< 0.5% Typical @ 85 to 264VAC input, 100% load  
< 1% Typical @ rated input, 0 to 100% load  
Startup with capacitive loads  
Residual Ripple Voltage (20MHz BW @ 25°C)  
Total PARD (Peak switching 20MHz BW @ nominal values)  
Power Derating above +50°C ambient Temp.  
Rise Time  
Max 8,000µF (@ Nominal Input Voltage & Nominal O/P Voltage,25°C)  
< 100mVpp.  
< 150mVpp.  
Derated Linearly 2.5% / °C  
< 30 ms @ full load, 25°C  
Start-Up Time  
< 2.5 s @ full load, 25°C  
Main Buffering (Hold-Up Time ,Power failure bypass)  
Dynamic Response (Overshoot & Undershoot O/P Voltage)  
> 90ms @ 230VAC & > 15ms @ 115VAC, 25°C  
+/-5% of 10% - 90% of full load.  
YES  
Parallel connection (Redundancy)  
with External Diode or Redundancy module (DRR-20A or DRR-40A)  
Surge voltage protection against internal surge voltages  
YES  
3.) Protection  
Over Voltage Protection  
Over load Protection  
Over current Protection  
Over Temperature Protection  
Short Circuit Protection  
> 32V +/-10%, SELV output, Non-Latching (Auto recovery).  
> 120% of rated load current, Auto Recovery (Hicc-up Mode).  
> 120% of rated load current, Auto Recovery (Hicc-up Mode).  
> 50°C Ambient Temp @ Max Load. Non-Latching (Auto-recovery).  
Bouncing mode and recovers automatically when the fault is removed.  
4.) Environmental  
Ambient temperature (Operating)  
-20°C to +50°C, with operation to 70°C possible with a linear derating to  
50% of nominal power from 50°C.  
Ambient temperature (Storage)  
Humidity Operation  
Shock Test (in all directions)  
Vibration (in all X,Y,Z direction)  
(Non-Operating)  
-25°C to 85°C  
< 95% RH non-condensing  
30G (300m/S2) according to IEC60068-2-27  
10 to 150Hz @ 50m/S2 (5G peak) according to IEC 60068-2-6.  
Note: all figures quoted are amplitudes (peak values).  
IEC/EN 60068-2-29; 11ms/ 10gn  
> 700,000 Hours.  
Bump  
MTBF  
Expected Life Time  
RoHS Compliant  
Altitude (Operating)  
Degree of protection  
Class of protection  
Pollution degree  
10 years.  
Yes, RoHS directive, WEEE directive  
@ 3,000 Meters  
IPX0  
Class I with PE connection  
2
Climatic class  
3K3 according to EN 60721  
2/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
5.) Mechanical Data  
Dimension  
Cooling System  
128 mm X 97 mm X 38 mm (L X W X H)  
Convection  
Input Terminal & Output Terminal  
Mounting Rail  
Connection  
Terminal Block 5 pin (300VAC, 20A)  
Standard T35 Mounting Rail (35mm) EN60715  
Screw Terminal  
Input wire size  
Output wire size  
Indicator  
AWG 22-14  
AWG 22-14  
Green LED “DC OK” LED (Same LED will Flicker upon fault)  
Type of housing  
Weight  
Aluminium  
0.300Kg  
6.) Certification/Safety Standards  
EMI : Immunity to interference according to EN 61000-6-2  
LEVEL 4  
15 KV  
EN 61000-4-2 1)  
Discharge of static electricity (ESD)  
Housing:  
Air Discharge:  
8 KV  
LEVEL 3  
Contact discharge:  
EN 61000-4-3 1)  
Housing:  
80MHz - 1GHz / 10V/M with 1kHz tone / 80% modulation.  
Radiate Field Immunity  
Frequency/Field intensity:  
EN 61000-4-4 1)  
LEVEL 3  
2KV4)  
Fast transients (Burst Immunity):  
IEC 61000-4-5 1)  
LEVEL 3  
2 KV3)  
Surge voltage Immunity:  
Common Mode:  
Differential Mode:  
I/O:  
1 KV4)  
EN 61000-4-6 1)  
LEVEL 3  
0.15MHz - 80MHz / 10Vrms.  
LEVEL 3  
10A/Meter  
Conducted Immunity  
Frequency / Uo:  
EN 61000-4-8 1)  
Power frequency magnetic field  
EN 61000-4-11 2)  
100% dip, Input: Main Buffering > 20ms.Self Recoverable  
Voltage dips  
EMC : Noise emission according to EN 61000-6-3  
FCC Title 47, Class B / EN55022, CISPR22, CISPR11, CLASS B5  
FCC Title 47, Class B / EN55022, CISPR22, CISPR11, CLASS B5  
Emitted radio interface  
Radio interference voltage  
Galvanic Isolation :  
Input / output  
Input / PE  
type test/routine test :  
type test/routine test :  
type test/routine test :  
3KVAC  
1.5KVAC  
0.5KVAC  
output / PE  
TUV to EN60950-1 and IEC60204-1  
(With overvoltage category III)  
TUV to EN50178 and IEC62103  
PELV (EN60204), SELV (EN60950)  
UR/cUR recognize to UL60950-1 and CSA C22.2 No.60950-1,  
CB test certificate and report to IEC60950-1/EN60950-1,  
TUV, CCC  
Electrical equipment of machines  
Electronic equipment for use in electrical power Installations  
Safety entry low voltage  
Electrical Safety for Information technology equipment  
UR/cUR Listed to UL508 and CSA C22.2,  
CE (EMC and Low Voltage directive)  
DIN 57100-410  
Electrical Safety for Industrial Control Equipment  
Protection against electric shock  
Conformance with EMC guideline 2004/108/EC  
and for low voltage guideline 2006/95/EC :  
Compliant with following standards :  
IEC60950-1/EN60950-1 : 2006/95/EC (Low Voltage Directive)  
EN55011 Class B  
EN55022 Class B  
: 2004/108/EC (EMC Directive)  
ITE  
EN55022, EN61000-3-2,EN61000-3-3, EN55024  
Industrial  
EN55011  
Limitation of mains harmonic currents  
EN61000-3-2  
EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EN 61000 corresponds to IEC 61000  
1) Criterion A:  
2) Criterion B:  
Normal operating behavior within the defined limits.  
Temporary impairment to operational behavior that is corrected by the device itself.  
3) Symmetrical: Conductor to conductor.  
4) Asymmetrical: Conductor to ground.  
5) Class B:  
Area of application industry and residential.  
3/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Numbering for Panel Mount Power Supply  
For example: PMC-24V075W1AA  
XX X XXXX XXXX X XX  
XXXX……………Watt  
XX X XXXX XXXX X XX  
XX………………….Product Type  
035W  
050W  
100W  
150W  
35 Watt  
50 Watt  
100 Watt  
150 Watt  
PM  
Panel Mount  
XX X XXXX XXXX X XX  
X………………….Model  
XX X XXXX XXXX X XX  
C
Enclose Power  
Supply  
X………………….Phase  
XX X XXXX XXXX X XX  
1
3
1 Phase  
3 Phase  
XXXX………………….Voltage  
XX X XXXX XXXX X XX  
24V  
24 Voltage  
XX………………….Variation (Eg,  
Customer, material,Etc.)  
AA  
Delta standard –  
product  
4/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Block Diagrams/Connections:  
Block Diagram of Power Supply  
PMC-24V075W1AA  
AC  
AC  
5/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Engineering Data  
Derating Curve  
PMC-24V075W1AA  
Note:  
1. Do not use the Power Supply in areas  
outside the shaded portion as shown in the  
above graph, internal parts may occasionally  
deteriorate or be damaged.  
2. For the power derating refer above graph  
ambient temperature > 50°C, the output  
capacity has to be reduced by 2.5% per  
Kelvin increase in temperature. If the output  
capacity is not reduced when Amb > 50°C  
device will run into thermal protection by  
switching off i.e. device will go in bouncing  
mode and will recover when Amb is lowered  
or load is reduced as far as necessary to  
keep device in working condition.  
3. If the power supply has to be mounted in any  
other direction please contact your service  
provider.  
4. In order for the device to function in the  
manner intended, it is also necessary to  
observe lateral spacing of 2 cm to other  
modules.  
5. Depending on the ambient temperature and  
load of the device, the temperature of the  
housing can become very high!  
6/13  
2/11/2011  
Rev: 01,  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Mechanical drawing  
Base Mounting (Vertical) Side Mounting (Horizontal)  
Side Mounting (Vertical)  
Device description (Fig. 1)  
1 Input & Output terminal block connector  
2 DC voltage adjustment potentiometer  
3 “DC OK” LED (green)  
Fig. 1. Mounting Orientation  
Stripped wire  
Lug  
Fig. 2. Wire Type  
7/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Over Load Protection  
The Power Supply is provided with an overload protection (OLP/OCP) function which protects the power  
supply from possible damage by over current. Additionally power supply also has over temperature  
protection (OTP) in case the over load condition persists for a longer duration and is below the overload  
trigger point but > 100% load.  
Typically the over load current (IOL) is > ISURGE (120%) output voltage will start drooping down when the  
power supply reaches max power limit and will run into bouncing mode when the output reaches UVLO  
(under voltage point). The output voltage will recover automatically when the overload condition is  
removed.  
Short Circuit Protection  
The Power Supply also has a short circuit protection which is in line with the overload protection and  
activates whenever there is a short across the output voltage, output goes in bouncing mode and  
remains until the fault is removed.  
Over Temperature Protection  
Additionally power supply also has over temperature protection (OTP) as mentioned above this OTP  
comes into picture when the over load condition persists for a longer duration and the output current level  
is below the overload trigger point but > 100% load.  
Also in the event of a higher ambient operating condition with 100% load the power supply will run into  
OTP when the Ambient temperature is >55°C. The protection is self recoverable when activated output  
voltage bounces until the operating ambient temperature of the power supply is reduced or the power  
supply is used within its power derating curve.  
8/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Over Voltage protection  
The Power Supply is protected by Over voltage in the event that power supply feedback circuit fails, the  
output voltage will not exceed 32V +/-10% Vdc under any Line/Load and operating ambient conditions.  
The unique feature about this over voltage protection (OVP) is that power supply doesn’t shut down but  
goes Hicc-up mode (Auto recovery) which is 32V+/-10%Vdc. The power supply output voltage will  
recover back to 24Vdc once the fault condition is removed.  
Inrush Current, Start Up Time, Output Hold Up Time  
Inrush Current,  
Inrush current is the first surge current seen on the input side when AC input is applied to the power  
supply. It is the first pulse captured; see a typical picture for the Inrush current as seen in the power  
supply.  
Start Up Time,  
Start up time is measured from the point AC input is applied and the o/p voltage reaches within 90% of  
its set value. See picture below for a typical start up time characteristic of a power supply.  
Rise Time,  
Rise time is the time needed for o/p voltage to rise from 10% of its set value to 90%. See the picture  
below for a typical rise time measurement in a power supply.  
9/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Hold Up Time,  
Hold up time is the time when the AC input collapses and o/p voltage retains regulation for a certain  
period of time is called as hold up time. See in the picture below a typical hold up time characteristic of  
a power supply. The hold time is measured until the o/p voltage remains in regulation hence it  
measured until the o/p voltage reaches 95% of its set value.  
Output Voltage Adjust  
The 24 V DC connection is made using the "+" and "–" screw connections. At the time of delivery, the  
output voltage is 24 V DC. The output voltage can be set from 22 to 28 VDC on the potentiometer  
seen as VADJ on the front panel of each power supply.  
10/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Dynamic Load  
Additionally power supply is capable of dynamic change of load from 0% to 100% with o/p voltage within  
+5% of regulation limits. See below the dynamic behavior of the power supply.  
Redundancy & Parallel Operation with Oring Diode  
See below figure for a typical Redundant/Parallel operation of PSU using CliQ series power supplies.  
The 2 power supplies PSU1 & PSU 2 are connected thru a twin diode where Anode1 A1 is connected to  
the +Ve i.e. 24V of PSU1 and Anode2 A2 is connected to the +Ve i.e. 24V of PSU2 and the output  
ground GND are shorted together.  
The output of these 2 power supplies PSU1 & PSU2 is drawn from the Cathode K of the twin diode thus  
making the power supply work in Redundant/Parallel operation.  
Redundant Operation:  
When 2 power supplies are connected in below manner the power supply PSU1 or PSU2 whichever has  
higher output voltage takes the max load and the other PSU is operating in standby (@No Load) in case  
of failure on PSU1, PSU2 takes over the load from PSU1 and supplies the required power to end system.  
11/13  
Rev: 01,  
2/11/2011  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Redundant / Parallel Operation with External Oring Diode  
12/13  
2/11/2011  
Rev: 01,  
Panel Mount Power Supply  
Technical Information  
PMC-24V075W1AA  
Parallel Operation:  
When 2 power supplies are also connected in the above manner they can share the Load provided following steps  
are taken.  
Step 1:  
Measure the o/p voltages @ NL measured from A1 to Gnd i.e. VA1 to Gnd of PSU1 and VA2 to Gnd of PSU2. If the  
voltages are not the same follow step 2. If the o/p voltages are the same skip step 2 and move to step 3.  
Step 2:  
Adjust the o/p voltages with the help of potentiometer available on the front panel of the PSU marked as ADJUST  
for both PSU1 and PSU2 at the same level for e.g. if PSU1 o/p is measuring 24.15Vdc and PSU2 is measuring  
24.25Vdc adjust the o/p voltage of either PSU1 close to 24.25Vdc or adjust the o/p voltage of PSU2 close to  
24.15Vdc.  
Step 3:  
Connect the PSU to the end system load and measure the o/p voltages from A1 to Gnd i.e. VA1 to Gnd of PSU1  
and VA2 to Gnd of PSU2. Ensure that o/p voltages are same even after the 2 power supplies are connected to  
load. If not then adjust them with the VR available on Front panel. A tolerance of + 25mV would be acceptable.  
Note:  
1. If the o/p voltage of any 1 power supply i.e. PSU1 or PSU2 is higher that power supply will take  
the initial load and also share the maximum load.  
2. If the o/p voltages adjusted are same then an equal load current sharing between the 2 power  
supplies can be achieved.  
3. The Oring diode must be of an appropriate rating, recommended rating of Oring Diode is  
minimum 4 times of the output load current and minimum reverse voltage rating of 45Vrr.  
4. A suitable heat sink is also advised to ensure that oring Diode is not over heated and damaged.  
5. Alternately, for redundant/parallel operation, use CliQ DRR-20A or DRR-40A (redundancy  
modules) for optimum performance.  
13/13  
Rev: 01,  
2/11/2011  

相关型号:

PMC24V150W1BA

24V 300W 1 Phase
DELTA

PMC24V150W3AA

24V 150W 1 Phase
DELTA

PMC24V150W3BA

24V 300W 1 Phase
DELTA

PMC271

Field Programmable Processor Array
PADAUK

PMC271-D08

Field Programmable Processor Array
PADAUK

PMC271-D14

Field Programmable Processor Array
PADAUK

PMC271-D16

Field Programmable Processor Array
PADAUK

PMC271-D20

Field Programmable Processor Array
PADAUK

PMC271-S08

Field Programmable Processor Array
PADAUK

PMC271-S14

Field Programmable Processor Array
PADAUK

PMC271-S16

Field Programmable Processor Array
PADAUK

PMC271-S18

Field Programmable Processor Array
PADAUK