PV-10A10F-CT [EATON]
10x38mm photovoltaic fuses — 1000 Vdc, 1-20 A;型号: | PV-10A10F-CT |
厂家: | Eaton All Rights Reserved. |
描述: | 10x38mm photovoltaic fuses — 1000 Vdc, 1-20 A |
文件: | 总4页 (文件大小:958K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
BUSSMANN
Effective September 2017
Supersedes July 2017
Technical Data 10121
SERIES
10x38mm photovoltaic fuses — 1000 Vdc, 1-20 A
Operating class
•ꢀ
gPV and UL PV fuse links
PV fuse coordination
•ꢀ
With thin film cells and 4”, 5” and 6” crystalline
silicon cells
Agency information
UL® Listed to 248-19*, Guide JFGA,
File E335324
•ꢀ
IEC® 60269-6 (gPV)
•ꢀ
Catalog symbols:
CSA® File 53787, Class 1422-30 (1-15 A),
•ꢀ
20 A pending
•ꢀ
PV-(amp)A10F (cylindrical)
CCC®
•ꢀ
•ꢀ
PV-(amp)A10-T (bolt mounting)
•ꢀ
RoHS compliant
•ꢀ
PV-(amp)A10-1P (single PCB tab)
•ꢀ
PV-(amp)A10-2P (dual PCB tab)
* Except crimp terminal version that is UL Recognized to
UL 248-19, Guide JFGA2, File E335324.
•ꢀ
PV-(amp)10F-CT (in-line with crimp terminals)
Packaging (carton quantity)
Description:
•ꢀ
PV-(amp)A10F, PV-(amp)A10T and
PV-(amp)A10-_P: 10
Eaton’s Bussmann™ series of 10x38mm,
1000Vdc PV fuses are for protecting and isolating
photovoltaic strings. The fuses are specifically
designed for use in PV systems with extreme
ambient temperature, high cycling and low fault
current conditions (reverse current, multi-array
fault) string arrays.
•ꢀ
PV-(amp)10F-CT in-line: 210
Features:
•ꢀ
Meets UL and IEC photovoltaic standards for
global acceptance
Four styles available for application flexibility.
•ꢀ
Low watts loss performance for energy
efficiency
Basic fuse size
•ꢀ
•ꢀ
10x38 mm
Low temperature rise performance for more
precise sizing
Ratings
•ꢀ
In-line crimp terminal version is easy to apply in
wire harness construction
•ꢀ
Volts 1000 Vdc
•ꢀ
Amps 1-20 A
Typical applications:
•ꢀ
•ꢀ
50 kA
Interrupting rating
Time constant: - 1-3ms
•ꢀ
Combiner boxes
•ꢀ
Inverters
•ꢀ
PV wire harnesses
Technical Data 10121
10x38mm photovoltaic fuses — 1000 Vdc, 1-20 A
Effective September 2017
Specifications:
Catalog numbers / configurations
PCB fixing
Energy integrals I2t (A2s)
Total @
Watts loss (W)
Current Voltage
Cylindrical
ferrule
In-line with
rating
rating
(Vdc)
Bolt fixing
PV-1A10-T
PV-2A10-T
PV-3A10-T
Single pin
Double pin
PV-1A10-2P
PV-2A10-2P
PV-3A10-2P
crimp terminal (amps)
Pre-arcing
1000 V
0.4
3.4
11
0.8In
0.8
0.6
0.8
0.9
1.0
1.0
1.1
1.2
1.2
1.5
1.7
2.1
In
PV-1A10F
PV-2A10F
PV-3A10F
PV-1A10-1P
PV-2A10-1P
PV-3A10-1P
PV-1A10F-CT
PV-2A10F-CT
PV-3A10F-CT
1
2
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
0.15
1.2
4
1.5
1.0
1.3
1.4
1.5
1.6
1.8
2.1
2.3
2.7
2.9
3.6
3
PV-3-5A10F PV-3-5A10-T PV-3-5A10-1P PV-3-5A10-2P PV-3-5A10F-CT
3.5
4
6.6
9.5
19
30
3
18
PV-4A10F
PV-5A10F
PV-6A10F
PV-8A10F
PV-10A10F
PV-4A10-T
PV-5A10-T
PV-6A10-T
PV-8A10-T
PV-4A10-1P
PV-5A10-1P
PV-6A10-1P
PV-8A10-1P
PV-4A10-2P
PV-5A10-2P
PV-6A10-2P
PV-8A10-2P
PV-4A10F-CT
PV-5A10F-CT
PV-6A10F-CT
PV-8A10F-CT
26
5
50
6
90
8
32
PV-10A10-T PV-10A10-1P PV-10A10-2P PV-10A10F-CT
10
12
15
20
7
70
PV-12A10F PV-12A10-T PV-12A10-1P PV-12A10-2P PV-12A10F-CT
PV-15A10F PV-15A10-T PV-15A10-1P PV-15A10-2P PV-15A10F-CT
PV-20A10F PV-20A10-T PV-20A10-1P PV-20A10-2P PV-20A10F-CT
12
22
34
120
220
350
Dimensions/configurations - mm:
Cylindrical PV-(amp)A10F
Cylindrical with bolt fixings PV-(amp)A10-T
58.9±±.9
10.3 0.1
38.0 0.ꢀ
6
6
9.5
51.1±1.ꢀ
11
Cylindrical with PCB tabs PV-(amp)A10-1P (single pin),
PV-(amp)A10-2P (double pin)
In-line with crimp terminals PV-(amp)A10F-CT
39.2±±.9ꢀTypeꢀ2P
7
Ø11.35
8
76.00
±.8
Typeꢀ2P
±.4
Typeꢀ1P
38.±ꢀTypeꢀ1P
The in-line crimp terminal version can be electrically insulated with
customer supplied overmolding or approved heat-shrink.
1.2
3
5.1
Operating temperature range
1P
2P
•ꢀ
-40°C to 90°C
Recommended fuse blocks, holders and fuseclips:
Wire range and type
Cat. no.
Description and date sheet/publication no.
Modular PV fuse block with optional covers 10265
1-Pole modular fuse holder with indication 10430
1-Pole modular fuse holder without indication 10430
2-Pole modular fuse holder with indication 10430
2-Pole modular fuse holder without indication 10430
PCB Fuseclips 2131
•ꢀ
Single conductor, 12-10AWG 75°C/90°C Cu stranded PV
BPVM-_
Overmolding temperature parameters
CHPV1IU
CHPV1U
CHPV2IU
CHPV2U
1A3400-_
HPV-DV-_A
•ꢀ
233°C for 180 sec Max
Terminals
•ꢀ
Crimp terminal for 12-10AWG PV copper conductors
Recommended tools
Sta-Kon® terminal crimping tool, catalog number ERG4002
•ꢀ
In-line fuse holder assembly 2157
2
Eaton.com/bussmannseries
10x38mm photovoltaic fuses — 1000 Vdc, 1-20 A
Technical Data 10121
Effective September 2017
Time-current characteristics
5
10 15
12 20
3.5
1
2 3
4
6
8
10,000
1000
100
6
4
2
6
4
2
6
4
2
10
6
4
2
1
6
4
2
0.1
2
4
6
8
1000
1
2
4
6
8
2
4
6
8
10
100
Available Current, DC - Time Constant < 1ms (Amps)
Eaton.com/bussmannseries
3
Technical Data 10121
10x38mm photovoltaic fuses — 1000 Vdc, 1-20 A
Effective September 2017
Temperature derating curves
No additional derating is required for PV fuse links installed in ganged modular fuse holders without spacing between units, provided that the
rating used is >1.56 x Isc.
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are
by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the
end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit
distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once
a product has been selected, it should be tested by the user in all possible applications.
Eaton and Bussmann are valuable
trademarks of Eaton in the US and other
countries.You are not permitted to use the
Eaton trademarks without prior written
consent of Eaton.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
Eaton.com
The CCC mark is administered by
Bussmann Division
114 Old State Road
Ellisville, MO 63021
United States
the Certification and Accreditation
Administration of the People’s Republic of
China.
CSA is a registered trademark of the
Canadian Standards Group.
Eaton.com/bussmannseries
IEC is a registered trademark of the
International Electrotechnical Commission.
Sta-Kon is a registered trademark of
Thomas & Betts.
UL is a registered trademark of the
Underwriters Laboratories, Inc
Follow us on social media to get the
latest product and support information.
© 2017 Eaton
All Rights Reserved
Printed in USA
Publication No. 10121 — BU-SB14107
September 2017
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明