HTP84F9AS [EMERSON-NETWORKPOWER]

Automation Transformers - Non-Ventilated 50 VA to 45 kVA;
HTP84F9AS
型号: HTP84F9AS
厂家: EMERSON NETWORK POWER    EMERSON NETWORK POWER
描述:

Automation Transformers - Non-Ventilated 50 VA to 45 kVA

文件: 总10页 (文件大小:326K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Dry Type Distribution Transformers  
Automation Transformers - Non-Ventilated 50 VA to 45 kVA  
SolaHD encapsulated transformers are rated for hazardous  
locations as well as harsh industrial environments.  
Encapsulation and rugged UL Listed/NEMA Type 3R  
enclosures protect the transformer from dust, moisture,  
and provides extra shock and vibration resistance. SolaHD  
transformers fully comply with the latest edition of the  
National Electrical Code for Class I, Division 2, Group A, B,  
C and D locations when installed in compliance with NEC  
501.100 (B).  
Features  
Single Phase: .05 - .250 kVA  
• UL Listed/NEMA Type 3R non encapsulated enclosure  
for indoor and outdoor service  
E25872  
E77014  
• Low temperature rise, UL Class I30 ˚C insulation system,  
80 ˚C temperature rise under full load  
• Conduit knockouts for side entry into wiring  
compartment  
Certifications and Compliances  
All Models  
• Copper lead wire terminations  
Single Phase: 0.500 - 25 kVA  
Three Phase: 3 - 45 kVA  
Listed: E25872, E77014  
- UL 1561 or UL 5085-1, UL 5085-2  
- CSA C22.2 No. 47 or No. 66  
- RoHS Compliant  
• Available as standard in Cold Rolled Steel or Painted  
Stainless Steel  
• UL Listed/NEMA Type 3R encapsulated enclosure for  
indoor and outdoor service  
Group 5, Export Models  
• Electrostatically shielded for quality power on sizes  
1 kVA and larger  
Low Voltage Directive  
- IEC 61558-1, IEC 61558-2-4  
• UL Class 200˚C insulation system, 115˚C  
temperature rise under full load  
• Conduit knockouts for side entry into wiring  
compartment (Type 3R versions only)  
Accessories and Optional Design Styles  
• Other enclosure styles available (contact Technical  
Support for details):  
• Copper lead wire terminations  
• .500 - 45 kVA units are encapsulated with electrical  
grade silica and epoxy for industrial applications  
- 316 Stainless Steel  
• Copper Wound designs  
• UL Listed/NEMA Type 4/12 or 4X Encapsulated  
Enclosures  
Related Products  
• Some SolaHD DC power supplies are available with  
Class I, Division 2 ratings or encapsulation.  
• Low temperature designs available  
• cULus Listed E361435 transformers for Class I,  
Division 2/Zone 2 hazardous locations are available as  
custom designs.  
• Surge Protective Devices  
Note: Weights and dimensions may change and should not be used for construction purposes.  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
© July 2020  
217  
Dry Type Distribution Transformers  
Selection Table: Single Phase  
Group 1: 240 x 480 Primary, 120/240 Secondary, 60 Hz  
Catalog Number Catalog Number  
Height  
Approx. Ship  
Weight  
lbs (kg)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Style 1  
Elec  
Primary  
Amps  
Secondary  
Amps  
kVA  
Group I  
Group II  
in (mm)  
Conn 1  
Rolled Steel  
Stainless Steel 2  
Non-Encapsulated  
.050  
.075  
.100  
.150  
.250  
6.00 (152.4)  
6.00 (152.4)  
6.00 (152.4)  
8.00 (203.2)  
8.00 (203.2)  
4.00 (101.6)  
4.00 (101.6)  
4.00 (101.6)  
4.00 (101.6)  
4.00 (101.6)  
3.00 (76.2)  
3.00 (76.2)  
3.00 (76.2)  
4.00 (101.6)  
4.00 (101.6)  
3.00 (1.36)  
3.00 (1.36)  
4.00 (1.81)  
5.00 (2.27)  
8.00 (3.63)  
2
2
2
2
2
15  
15  
15  
15  
15  
.208/.104  
.312/.156  
.417/.208  
.625/.313  
1.04/.512  
0.416/0.208  
0.625/0.312  
0.833/0.417  
1.25/.625  
HS1B50  
HS1B75  
HS1B100  
HS1B150  
HS1B250  
N/A  
2.08/1.04  
Encapsulated  
0.5  
0.75  
1
10.00 (254.0) 6.00 (152.4)  
10.00 (254.0) 6.00 (152.4)  
10.00 (254.0) 6.00 (152.4)  
5.00 (127.0)  
22.0 (9.98)  
27.0 (12.25)  
28.0 (12.70)  
38.0 (17.24)  
45.0 (20.42)  
55.0 (24.95)  
3
3
3
4
4
4
4
4
4
4
4
15  
15  
16  
16  
16  
17  
17  
18  
18  
18  
18  
2.08/1.04  
3.13/1.56  
4.17/2.08  
6.25/3.13  
8.33/4.17  
12.5/6.25  
20.8/10.4  
31.3/15.6  
41.7/20.8  
62.5/31.2  
104.0/52.0  
4.16/2.08  
6.25/3.13  
8.33/4.17  
12.5/6.25  
16.7/8.33  
25.0/12.5  
41.6/20.8  
62.5/31.3  
83.3./41.7  
125.0/62.5  
208.0/104.0  
HS1F500B  
HS1F750B  
HS1F1BS  
HSP1F500B  
HSP1F750B  
HSP1F1BS  
HSP1F1.5AS  
HSP1F2AS  
HSP5F3AS  
HSP5F5AS  
HSP5F7.5AS  
HSP5F10AS  
HSP5F15BS  
HSP5F25BS  
5.00 (127.0)  
5.00 (127.0)  
1.5  
2
12.00 (304.8) 10.00 (254.0) 7.00 (177.8)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8)  
HS1F1.5AS  
HS1F2AS  
3
HS5F3AS  
5
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 131.0 (59.42)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 155.0 (70.31)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 166.0 (75.30)  
24.00 (610.0) 17.00 (432.0) 12.50 (318.0) 375.0 (170.00)  
24.00 (610.0) 17.00 (432.0) 12.50 (318.0) 400.0 (181.00)  
HS5F5AS  
7.5  
10  
15  
25  
HS5F7.5AS  
HS5F10AS  
HS5F15BS 3  
HS5F25BS 3  
Group 2: 600 Volt Primary, 120/240 Secondary, 60 Hz  
Catalog Number  
Group 1  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Elec  
Primary  
Amps  
Secondary  
Amps  
kVA  
Style 1  
Conn 1  
Stainless Steel 2  
Non-Encapsulated  
6.00 (152.4) 4.00 (101.6) 3.00 (76.2)  
.100  
.150  
.250  
4.00 (1.81)  
2
2
2
21  
21  
21  
0.167  
0.25  
.833/.417  
1.25/.625  
2.08/1.04  
HS10B100  
HS10B150  
HS10B250  
8.00 (203.2) 4.00 (101.6) 4.00 (101.6) 5.00 (2.27)  
8.00 (203.2) 4.00 (101.6) 4.00 (101.6) 8.00 (3.63)  
N/A  
0.417  
Encapsulated  
.500  
.750  
1
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 22.0 (9.98)  
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 23.0 (10.43)  
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 28.0 (12.70)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 38.0 (17.24)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 60.0 (27.22)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 66.0 (29.94)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 100.0 (45.36)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 135.0 (61.23)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 150.0 (68.04)  
3
3
3
4
4
4
4
4
4
21  
21  
21  
21  
21  
22  
22  
22  
22  
0.833  
1.25  
1.67  
2.5  
4.16/2.08  
6.25/3.13  
8.33/4.17  
12.5/6.25  
16.7/8.33  
25.0/12.5  
41.6/20.8  
62.5/31.3  
83.3/41.7  
HS10F500B  
HS10F750B  
HS10F1BS  
HS10F1.5AS  
HS10F2AS  
HS10F3AS  
HS10F5AS  
HS10F7.5AS  
HS10F10AS  
HSP10F500B  
HSP10F750B  
HSP10F1BS  
HSP10F1.5AS  
HSP10F2AS  
HSP10F3AS  
HSP10F5AS  
HSP10F7.5AS  
HSP10F10AS  
1.5  
2
3.33  
5.0  
3
5
8.3  
7.5  
10  
12.5  
16.7  
Notes:  
1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section.  
2. Contact Technical Services for other enclosure types.  
3. Supersedes Previous Designs, Please Contact Technical Services Regarding HS5F15AS or HSF25AS Enclosure Options.  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
218  
© July 2020  
Dry Type Distribution Transformers  
Selection Table: Single Phase  
Group 3: 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz  
Catalog Number  
Group 1  
Rolled Steel  
Catalog Number  
Group 2  
Approx. Ship  
Weight  
lbs (kg)  
Primary  
Amps  
@ 277 V  
Design  
Style 1  
Elec  
Conn 1  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Secondary  
Amps  
kVA  
Stainless Steel 3  
Encapsulated  
1
1.5  
2
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 29.0 (13.15)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 40.0 (18.14)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 60.0 (27.22)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 66.0 (29.94)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 104.0 (47.17)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 135.0 (61.23)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 156.0 (70.76)  
3
4
4
4
4
4
4
19  
20  
20  
20  
20  
20  
20  
3.6  
5.4  
8.33/4.17  
12.5/6.25  
16.7/8.33  
25.0/12.5  
41.6/20.8  
62.5/31.3  
83.3/41.7  
HS12F1BS  
HS12F1.5AS  
HS12F2AS  
HS12F3AS  
HS12F5AS  
HS12F7.5AS  
HS12F10AS  
HSP12F1BS  
HSP12F1.5AS  
HSP12F2AS  
HSP12F3AS  
HSP12F5AS  
HSP12F7.5AS  
HSP12F10AS  
7.2  
3
10.8  
18.0  
27.1  
36.1  
5
7.5  
10  
Group 4: 190/200/208/220/380/400/415/440 Volt Primary, 110/220 Secondary, 50/60 Hz Copper wound  
200/208/230/400/415/460 Volt Primary, 115/230 Secondary, 50/60 Hz Copper wound  
208/240/415/480 Volt Primary, 120/240 Secondary, 60 Hz only Copper wound  
Catalog Number  
Group 1  
Rolled Steel  
Catalog Number  
Group 2  
Approx. Ship  
Weight  
lbs (kg)  
Design  
Style 1  
Elec  
Conn 1  
Primary  
Amps 2  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Secondary  
Amps  
kVA  
Stainless Steel 3  
Encapsulated, Copper Wound  
1
1.5  
2
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 34.0 (15.42)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 40.0 (18.13)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 60.0 (27.21)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 73.0 (33.11)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 100.0 (45.36)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 140.0 (63.50)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 175.0 (79.38)  
3
4
4
4
4
4
4
23  
24  
24  
24  
24  
24  
24  
4.5/2.3  
6.8/3.4  
9.1/4.5  
13.6/6.8  
9.1/4.5  
13.6/6.8  
18.2/9.1  
27.3/13.6  
HS14F1BS  
HS14F1.5BS  
HS14F2BS  
HS14F3BS  
HS14F5BS  
HS14F7.5BS  
HS14F10BS  
HSP14F1BS  
HSP14F1.5BS  
HSP14F2BS  
HSP14F3BS  
HSP14F5BS  
HSP14F7.5BS  
HSP14F10BS  
3
5
22.7/11.4 45.5/22.7  
34.1/17.0 68.2/34.1  
45.5/22.7 90.9/45.5  
7.5  
10  
Group 5: Export 190/200/208/220/380/400/415/440 Volt Primary, 110/220 Secondary, 50/60 Hz Copper wound  
Export 200/208/230/400/415/460 Volt Primary, 115/230 Secondary, 50/60 Hz Copper wound  
Export 208/240/415/480 Volt Primary, 120/240 Secondary, 60 Hz only Copper wound  
Catalog Number  
Group 1  
Rolled Steel  
Catalog Number  
Group 2  
Approx. Ship  
Weight  
lbs (kg)  
Design  
Style 1  
Elec  
Conn 1  
Primary  
Amps 2  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Secondary  
Amps  
kVA  
Stainless Steel 3  
Encapsulated, Copper Wound  
1
1.5  
2
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 52.0 (23.6)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 55.0 (25.0)  
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 62.0 (28.1)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 142.0 (64.4)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 146.0 (66.2)  
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 175.0 (79.4)  
4
4
4
4
4
4
24  
24  
24  
24  
24  
24  
4.5/2.3  
6.8/3.4  
9.1/4.5  
13.6/6.8  
9.1/4.5  
13.6/6.8  
18.2/9.1  
27.3/13.6  
HS14F1CS-CE  
HSP14F1CS-CE  
HS14F1.5CS-CE HSP14F1.5CS-CE  
HS14F2CS-CE  
HS14F3CS-CE  
HS14F5CS-CE  
HSP14F2CS-CE  
HSP14F3CS-CE  
HSP14F5CS-CE  
3
5
22.7/11.4 45.5/22.7  
34.1/17.0 68.2/34.1  
7.5  
HS14F7.5CS-CE HSP14F7.5CS-CE  
Notes:  
1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section.  
2. Amperage calculated at 220/440 Volts on primary. UL Listed. 240 and 480 V not available at 50 Hz.  
3. Contact Technical Services for other enclosure types.  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
© July 2020  
219  
Dry Type Distribution Transformers  
Selection Tables: Three Phase  
Group A: 480 Volt Δ Primary, 208Y/120 Secondary, 60 Hz  
Catalog Number  
Group I  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Style 1  
Elec  
Primary Secondary  
kVA  
Conn 1  
Amps  
Amps  
Stainless Steel 3  
3
6
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 105.0 (47.63)  
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 250.0 (113.40)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 261.0 (118.39)  
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 696.0 (315.70)  
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 844.0 (382.83)  
4
4
4
4
4
4
27  
27  
27  
27  
27  
27  
3.6  
7.2  
8.3  
16.6  
25.0  
41.7  
83.4  
125.0  
HT1F3AS  
HT1F6AS  
HT1F9AS  
HT1F15AS  
HT1F30AS  
HT1F45AS  
HTP1F3AS  
HTP1F6AS  
HTP1F9AS  
HTP1F15AS  
HTP1F30AS  
HTP1F45AS  
9
10.8  
18.1  
36.1  
54.2  
15  
30  
45  
Group B: 208 Volt Δ Primary, 208Y/120 Secondary, 60 Hz  
Catalog Number  
Group I  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Design  
Style 1  
Elec  
Conn 1  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Primary  
Amps  
Secondary  
Amps  
kVA  
Stainless Steel 3  
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 97.0 (44.00)  
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12)  
4
4
4
26  
26  
26  
7.2  
8.3  
HT3F3AS  
HT3F6AS  
HT3F9AS  
HTP3F3AS  
HTP3F6AS  
HTP3F9AS  
14.4  
21.7  
16.6  
25.0  
Group C: 480 Volt Δ Primary,240 Volt Δ Secondary with 120 V reduced capacity center tap, 60 Hz 2  
Catalog Number  
Group I  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Style 1  
Elec  
Primary  
Amps  
Secondary  
Amps  
kVA  
Conn 1  
Stainless Steel 3  
3
6
13.00 (330.2) 16.00 (406.4) 9.00 (228.6)  
13.00 (330.2) 16.00 (406.4) 9.00 (228.6)  
105.0 (47.63)  
150.0 (68.03)  
4
4
4
4
4
4
28  
28  
28  
28  
28  
28  
3.6  
7.2  
7.2  
14.4  
21.7  
36.1  
72.2  
108.3  
HT5F3AS  
HT5F6AS  
HT5F9AS  
HT5F15AS  
HT5F30AS  
HT5F45AS  
HTP5F3AS  
HTP5F6AS  
HTP5F9AS  
HTP5F15AS  
HTP5F30AS  
HTP5F45AS  
9
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 250.0 (113.40)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 305.0 (138.35)  
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 698.0 (316.61)  
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 876.0 (397.35)  
10.8  
18.1  
36.1  
54.2  
15  
30  
45  
Group D: 240 Volt Δ Primary, 208Y/120 Secondary, 60 Hz  
Catalog Number  
Group I  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Style 1  
Elec  
Primary  
Amps  
Secondary  
Amps  
kVA  
Conn 1  
Stainless Steel 3  
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 97.0 (44.00)  
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12)  
4
4
4
25  
25  
25  
7.2  
8.3  
HT6F3AS  
HT6F6AS  
HT6F9AS  
HTP6F3AS  
HTP6F6AS  
HTP6F9AS  
14.4  
21.7  
16.6  
25.0  
Notes:  
1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section.  
2. Refer to Capacity of Center Tap in Center Tap Delta Transformers at the beginning of this section.  
3. Contact Technical Services for other enclosure types.  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
220  
© July 2020  
Dry Type Distribution Transformers  
Selection Tables: Three Phase  
Group E: 480 Volt Δ Primary, 380Y/220 Secondary, 60 Hz  
Catalog Number  
Group I  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Style 1  
Elec  
Primary Secondary  
kVA  
Conn 1  
Amps  
Amps  
Stainless Steel 2  
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 121.0 (54.88)  
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 255.0 (115.7)  
4
4
4
29  
29  
29  
3.6  
7.2  
4.6  
9.1  
HT79F3AS  
HT79F6AS  
HT79F9AS  
HTP79F3AS  
HTP79F6AS  
HTP79F9AS  
10.8  
13.6  
Group F: 600 Volt Δ Primary, 208Y/120 Secondary, 60 Hz  
Catalog Number  
Group I  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Elec  
Primary  
Amps  
Secondary  
Amps  
kVA  
Style 1  
Conn 1  
Stainless Steel 2  
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 116.0 (52.62)  
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 225.0 (115.67)  
4
4
4
30  
30  
30  
2.9  
5.8  
8.7  
8.3  
HT7F3AS  
HT7F6AS  
HT7F9AS  
HTP7F3AS  
HTP7F6AS  
HTP7F9AS  
16.6  
25.0  
Group G: 208 Volt Δ Primary, 480Y/277 Secondary, 60 Hz  
Catalog Number  
Group I  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Style 1  
Elec  
Primary  
Amps  
Secondary  
Amps  
kVA  
Conn 1  
Stainless Steel 2  
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6)  
97.0 (44.00)  
4
4
4
31  
31  
31  
8.3  
3.6  
7.2  
HT84F3AS  
HT84F6AS  
HT84F9AS  
HTP84F3AS  
HTP84F6AS  
HTP84F9AS  
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12)  
16.6  
25.0  
10.8  
Group H: 240 Volt Δ Primary, 480Y/277 Secondary, 60 Hz  
Catalog Number  
Group I  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Style 1  
Elec  
Primary  
Amps  
Secondary  
Amps  
kVA  
Conn 1  
Stainless Steel 2  
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6)  
97.0 (44.00)  
4
4
4
32  
32  
32  
7.2  
3.6  
7.2  
HT85F3AS  
HT85F6AS  
HT85F9AS  
HTP85F3AS  
HTP85F6AS  
HTP85F9AS  
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12)  
14.4  
21.6  
10.8  
Group J: 480 Volt Δ Primary, 480Y/277 Secondary, 60 Hz  
Catalog Number  
Group I  
Rolled Steel  
Catalog Number  
Group II  
Approx. Ship  
Weight  
lbs (kg)  
Height  
in (mm)  
Width  
in (mm)  
Depth  
in (mm)  
Design  
Elec  
Primary Secondary  
kVA  
Style 1  
Conn 1  
Amps  
Amps  
Stainless Steel 2  
3
6
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 121.0 (54.88)  
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 255.0 (115.7)  
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 261.0 (118.39)  
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 696.0 (315.70)  
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 844.0 (382.83)  
4
4
4
4
4
4
33  
33  
33  
33  
33  
33  
3.6  
7.2  
3.6  
7.2  
HT81F3AS  
HT81F6AS  
HT81F9AS  
HT81F15AS  
HT81F30AS  
HT81F45AS  
HTP81F3AS  
HTP81F6AS  
HTP81F9AS  
HTP81F15AS  
HTP81F30AS  
HTP81F45AS  
9
10.8  
18.1  
36.1  
54.2  
10.8  
18.1  
36.1  
54.2  
15  
30  
45  
Notes:  
1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section.  
2. Contact Technical Services for other enclosure types.  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
© July 2020  
221  
Dry Type Distribution Transformers  
Design Styles  
D
W
H
Style 2 - Non-Encapsulated  
W
D
H
Style 3 - Encapsulated  
Style 4 - Encapsulated  
Customized Enclosures - Contact Technical Services  
Style 5 - Encapsulated  
Available for all encapsulated kVA sizes (For Type 4, 12 and 4X)  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
222  
© July 2020  
Dry Type Distribution Transformers  
Electrical Connections (Single Phase)  
240 X 480 Volt Primary  
120/240 Volt Secondary  
Taps: None  
240 X 480 Volt Primary  
120/240 Volt Secondary  
Taps: None  
240 X 480 Volt Primary  
120/240 Volt Secondary  
Taps: 2, 2½% FCAN & FCBN  
15  
16  
17  
H8  
H1  
H2H3 H4  
H5 H6  
H7  
H1  
H3  
H2  
H4  
H1  
H3  
H2  
H4  
SHIELD  
X4  
X1  
X3  
X2  
SHIELD  
Primary Voltage  
Interconnect  
H4 to H5  
H3 to H5  
H3 to H6  
H2 to H6  
H2 to H7  
Connect Lines to  
H1 & H8  
X1  
X3  
X2  
X4  
X1  
X3  
X2  
X4  
504  
492  
480  
468  
456  
Primary Voltage  
Interconnect  
Connect Lines to  
Primary Voltage  
Interconnect  
Connect Lines to  
H1 & H8  
480  
H2 to H3  
H1 & H4  
H1 & H8  
480  
H2 to H3  
H1 & H4  
H1 to H3  
H2 to H4  
H1 & H8  
H1 to H3  
H2 to H4  
240  
H1 & H4  
240  
H1 & H4  
H1 & H8  
Secondary Voltage  
Interconnect  
Connect Lines to  
Secondary Voltage  
Interconnect  
Connect Lines to  
H1 to H5  
H4 to H8  
252  
240  
228  
H1 & H8  
H1 & H8  
H1 & H8  
240  
X2 to X3  
X1 & X4  
240  
X2 to X3  
X1 & X4  
H1 to H6  
H3 to H8  
X2 to X3  
X2 to  
X2 to X3  
X2 to  
120-0-120  
120  
X1-X2-X4  
X1 & X4  
120-0-120  
120  
X1-X2-X4  
X1 & X4  
H1 to H7  
H2 to H8  
X1 to X3  
X2 to X4  
X1 to X3  
X2 to X4  
Secondary Voltage  
Interconnect  
Connect Lines to  
HS1 Series  
HS1 Series  
240  
X2 to X3  
X1 & X4  
240 X 480 Volt Primary,  
120/240 Volt Secondary  
Taps: 2, 2½% FCAN; 4, 2½% FCBN  
X2 to X3  
X2 to  
120-0-120  
120  
X1-X2-X4  
X1 & X4  
18  
H6 H7 H8 H9 H10  
120/208/240/277 Volt Primary  
120/240 Volt Secondary  
Taps: None  
19  
X1 to X3  
X2 to X4  
H1  
H2 H3 H4 H5  
H1  
H3  
H2  
H4 H5 H6  
HS5 Series  
120/208/240/277 Volt Primary  
120/240 Volt Secondary  
Taps: None  
SHIELD  
20  
H8  
X1  
X3  
X2  
X4  
SHIELD  
H1 H2 H3  
H4  
H6  
H7  
H5  
Primary Voltage  
Interconnect  
Connect Lines to  
H1 & H10  
H1 & H10  
H1 & H10  
H1 & H10  
H1 & H10  
H1 & H10  
H1 & H10  
X1  
X3  
X2  
X4  
504  
492  
480  
468  
456  
444  
432  
H5 to H6  
H4 to H6  
H4 to H7  
H3 to H7  
H3 to H8  
H2 to H8  
H2 to H9  
Primary Voltage  
Interconnect  
H2 to H3  
H2 to H3  
H2 to H3  
Connect Lines to  
H1 & H6  
SHIELD  
X4  
277  
240  
208  
X1  
X3  
X2  
H1 & H5  
Primary Voltage  
Interconnect  
H4 to H5  
H3 to H6  
H2 to H7  
Connect Lines to  
H1 & H8  
H1 & H4  
277  
240  
208  
H1 to H3  
H2 to H5  
120  
H1 & H5  
H1 & H8  
Secondary Voltage  
Interconnect  
Connect Lines to  
H1 & H8  
H1 to H6  
H5 to H10  
252  
240  
228  
216  
H1 & H10  
H1 & H10  
H1 & H10  
H1 & H10  
240  
X2 to X3  
X1 & X4  
H1 to H6  
H3 to H8  
120  
H1 & H8  
H1 to H7  
H4 to H10  
X2 to X3  
X2 to  
120-0-120  
120  
X1-X2-X4  
X1 & X4  
Secondary Voltage  
Interconnect  
Connect Lines to  
H1 to H8  
H3 to H10  
X1 to X3  
X2 to X4  
240  
X2 to X3  
X1 & X4  
X2 to X3  
X2 to  
H1 to H9  
H2 to H10  
120-0-120  
120  
X1-X2-X4  
X1 & X4  
HS12 Series (1 kVA only)  
X1 to X3  
X2 to X4  
Secondary Voltage  
Interconnect  
Connect Lines to  
240  
X2 to X3  
X1 & X4  
= Earth Ground  
HS12 Series  
X2 to X3  
X2 to  
120-0-120  
120  
X1-X2-X4  
X1 & X4  
X1 to X3  
X2 to X4  
Note:  
Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and  
the system ground (white). Specifications are subject to change without notice.  
HS5 Series  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
© July 2020  
223  
Dry Type Distribution Transformers  
Electrical Connections (Single Phase)  
600 Volt Primary  
120/240 Volt Secondary  
Taps: 2, 5% FCBN  
22 190/200/208/220/380/400/415/4402Vol3t Pri.  
H6  
600 Volt Primary,  
120/240 Volt Secondary  
Taps: None  
110/220 Volt Secondary  
21  
Taps: None  
H1 H2 H3 H4 H5  
H6 H7 H8 H9 H10  
H1  
H2 H3  
H4 H5  
H1  
H2  
SHIELD  
SHIELD  
X4  
X1  
Primary Voltage  
X3  
X2  
X4  
X1  
X3  
X2  
Interconnect  
H3 to H4  
H2 to H4  
H2 to H5  
Connect Lines to  
H1 & H6  
X1  
X3  
X2  
X4  
Primary Voltage  
Interconnect  
Connect Lines to  
600  
570  
540  
Primary Voltage  
Interconnect  
Connect Lines to  
440/460/480  
415  
H5 to H6  
H4 to H6  
H3 to H6  
H2 to H6  
H1 & H10  
H1 & H9  
H1 & H8  
H1 & H7  
H1 & H6  
600  
H1 & H2  
H1 & H6  
400/415  
380/400  
Secondary Voltage  
Interconnect  
X2 to X3  
Connect Lines to  
Secondary Voltage  
Interconnect  
Connect Lines to  
240  
X1 & X4  
240  
X2 to X3  
X1 & X4  
H1 to H6  
H5 to H10  
X2 to X3  
220/230/240  
208  
H1 & H10  
H1 & H9  
H1 & H8  
H1 & H7  
120-0-120  
120  
X1, X2 & X4  
X1 & X4  
X2 to X3  
X2 to  
X2 to  
m
120-0-120  
120  
X1-X2-X4  
X1 & X4  
H1 to H6  
H4 to H9  
X1 to X3  
X2 to X4  
X1 to X3  
X2 to X4  
H1 to H6  
H3 to H8  
HS10 Series  
200/208  
HS10 Series  
Note:1 through 2 kVA units have electrostatic  
shielding.  
H1 to H6  
H2 to H7  
190/200/208  
Secondary Voltage  
Interconnect  
Connect Lines to  
190/200/208/220/380/400/415/440 Volt Pri.  
110/220 Volt Secondary  
220/230/240  
X2 to X3  
X1 & X4  
Taps: None  
24  
110,220/115,  
230/120,240  
X2 to X3  
X2 to  
X1, X2 & X4  
X1 & X4  
H1  
H2 H3 H4 H5  
H6 H7 H8 H9 H10  
X1 to X3  
X2 to X4  
110/115/120  
HS14F1BS  
SHIELD  
X1  
X3  
Interconnect  
X2  
X4  
Primary Voltage  
Connect Lines to  
440/460/480  
415  
H5 to H6  
H4 to H7  
H1 & H10  
H1 & H10  
400/415  
380/400  
H3 to H8  
H2 to H9  
H1 & H10  
H1 & H10  
H1 to H6,  
H5 to H10  
220/230/240  
208  
H1 & H10  
H1 & H10  
H1 & H10  
H1 & H10  
H1 to H7,  
H4 to H10  
H1 to H8,  
H3 to H10  
200/208  
H1 to H9  
H2 to H10  
190/200/208  
Secondary Voltage  
Interconnect  
Connect Lines to  
= Earth Ground  
220/230/240  
X2 to X3  
X1 & X4  
X2 to X3  
X2 to  
110,220/115,  
230/120,240  
X1, X2 & X4  
X1 & X4  
X1 to X3  
X2 to X4  
Note:  
110/115/120  
Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and  
the system ground (white). Specifications are subject to change without notice.  
HS14 Series  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
224  
© July 2020  
Dry Type Distribution Transformers  
Electrical Connections (Three Phase)  
240 Δ Volt Primary  
208Y/120 Volt Secondary  
Taps: 2, 5% FCBN  
H1  
208 Δ Volt Primary  
208Y/120 Volt Secondary  
Taps: 2, 5% FCBN  
480 Δ Volt Primary  
208Y/120 Volt Secondary  
Taps: 2, 5% FCBN  
25  
H3  
27  
H3  
26  
H2  
H1  
H2  
H3  
H1  
H2  
7 4 1  
8 5 2  
9 6 3  
7 4 1  
8 5 2  
9 6 3  
7 4 1  
8 5 2  
9 6 3  
SHIELD  
X3  
SHIELD  
SHIELD  
X0  
X1  
X2  
X0  
X1  
X2  
X3  
X0  
X1  
H2  
X2  
X3  
X2  
H2  
X2  
X3  
X2  
X3  
H2  
X1  
X0  
X1  
X0  
X1  
X0  
H1  
H3  
Connect Taps  
X3  
H1  
H3  
H1  
H3  
Primary  
Voltage  
Connect  
Lines To  
Primary  
Voltage  
Connect  
Lines To  
Primary  
Voltage  
Connect  
Lines to  
Connect Taps  
Interconnect  
240  
1-H1 & 2-H2 & 3-H3  
4-H1 & 5-H2 & 6-H3  
7-H1 & 8-H2 & 9-H3  
H1, H2, H3  
H1, H2, H3  
H1, H2, H3  
208  
1-H1 & 2-H2 & 3-H3  
4-H1 & 5-H2 & 6-H3  
7-H1 & 8-H2 & 9-H3  
H1, H2, H3  
H1, H2, H3  
H1, H2, H3  
480  
1-H1 & 2-H2 & 3-H3  
4-H1 & 5-H2 & 6-H3  
7-H1 & 8-H2 & 9-H3  
H1, H2, H3  
H1, H2, H3  
H1, H2, H3  
228  
456  
198  
216  
187  
432  
Secondary  
Voltage  
Connect  
Lines To  
Secondary  
Voltage  
Connect  
Lines To  
Secondary  
Voltage  
Connect  
Lines to  
208  
120  
X1, X2, & X3  
208  
120  
X1, X2, & X3  
208  
120  
X1, X2, & X3  
X0, X1, X2, X3  
X0, X1, X2, X3  
X0, X1, X2, X3  
HT6 Series  
HT3 Series  
HT1 Series  
480 Δ Volt Primary  
480 Δ Volt Primary  
240 Δ w/120 CT Volt Secondary  
Taps: 2, 5% FCBN  
380Y/220 Volt Secondary  
Taps: 2, 5% FCBN  
29  
28  
H3  
H1  
H2  
H3  
H1  
H2  
7 4 1  
8 5 2  
9 6 3  
7 4  
1
8
5
2
9 6 3  
SHIELD  
X3  
SHIELD  
X0  
X1  
X2  
X6  
X1  
X2  
X3  
X2  
H2  
H2  
X2  
X6  
X1  
X0  
H1  
H3  
X1  
X3  
H1  
H3  
X3  
Primary  
Voltage  
Connect  
Lines to  
Primary  
Voltage  
Connect  
Taps  
Connect  
Lines To  
Interconnect  
480  
1-H1 & 2-H2 & 3-H3  
4-H1 & 5-H2 & 6-H3  
7-H1 & 8-H2 & 9-H3  
H1, H2 & H3  
H1, H2 & H3  
H1, H2 & H3  
480  
456  
432  
1-H1 & 2-H2 & 3-H3  
4-H1 & 5-H2 & 6-H3  
7-H1 & 8-H2 & 9-H3  
H1, H2, H3  
H1, H2, H3  
H1, H2, H3  
456  
432  
= Earth Ground  
Secondary  
Voltage  
Connect  
Lines to  
Secondary  
Voltage  
Connect  
Lines To  
Interconnect  
Interconnect  
380  
220  
X1, X2, X3  
240  
X1, X2, X3  
X1-X6-X3  
Notes:  
X0, X1, X2, X3  
120-0-120  
X6 to  
Connect the electrostatic shield to the equipment  
ground (green) or to both the equipment ground  
and the system ground (white). Specifications are  
subject to change without notice.  
HT79 Series  
HT5 Series  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
© July 2020  
225  
Dry Type Distribution Transformers  
Electrical Connections (Three Phase)  
600 Δ Volt Primary  
208Y/120 Volt Secondary  
Taps: 2, 5% FCBN  
208 Δ Volt Primary  
480Y/277 Volt Secondary  
Taps: 2, 5% FCBN  
240 Δ Volt Primary  
480Y/277 Volt Secondary  
Taps: 2, 5% FCBN  
32  
30  
H3  
31  
X3  
H1  
H2  
X2  
X1  
X2  
X3  
X1  
7 4 1  
8 5 2  
9 6  
3
7 4 1  
8 5 2  
9 6 3  
7 4 1  
8 5 2  
9 6 3  
SHIELD  
X3  
SHIELD  
H3  
SHIELD  
H3  
X0  
X1  
X2  
H0  
H1  
H2  
H0  
H1  
H2  
X2  
H2  
H2  
H3  
H2  
X2  
X2  
X1  
X0  
H1  
H0  
H1  
H0  
H1  
H3  
X3  
X1  
X3  
X1  
X3  
H3  
Primary  
Voltage  
Primary  
Voltage  
Primary  
Voltage  
Connect Taps  
Line Leads  
Connect Taps  
Line Leads  
Connect Taps  
Line Leads  
600  
1-H1 & 2-H2 & 3-H3  
4-H1 & 5-H2 & 6-H3  
7-H1 & 8-H2 & 9-H3  
H1, H2, H3  
H1, H2, H3  
H1, H2, H3  
208  
1-X1 & 2-X2 & 3-X3  
4-X1 & 5-X2 & 6-X3  
7-X1 & 8-X2 & 9-X3  
X1, X2, X3  
X1, X2, X3  
X1, X2, X3  
240  
1-X1 & 2-X2 & 3-X3  
4-X1 & 5-X2 & 6-X3  
7-X1 & 8-X2 & 9-X3  
X1, X2, X3  
X1, X2, X3  
X1, X2, X3  
570  
198  
228  
540  
187  
216  
Secondary  
Voltage  
Secondary  
Voltage  
Secondary  
Voltage  
Line Leads  
Line Leads  
Line Leads  
208  
120  
X1, X2, X3  
480  
277  
H1, H2, H3  
480  
277  
H1, H2, H3  
X0, X1, X2, X3  
H0, H1, H2, H3  
H0, H1, H2, H3  
HT7 Series  
HT84 Series  
HT85 Series  
480 Δ Volt Primary  
480Y/277 Volt Secondary  
Taps: 2, 5% FCBN  
33  
H1  
H2  
H3  
7 4 1  
8 5 2  
9 6 3  
SHIELD  
X3  
X0  
X1  
X2  
X2  
X3  
H2  
X1  
X0  
H1  
H3  
Primary  
Voltage  
Connect  
Lines to  
Interconnect  
480  
1-H1 & 2-H2 & 3-H3  
4-H1 & 5-H2 & 6-H3  
7-H1 & 8-H2 & 9-H3  
H1, H2 & H3  
H1, H2 & H3  
H1, H2 & H3  
456  
432  
Secondary  
Voltage  
Connect  
Lines to  
Interconnect  
480  
277  
X1, X2, X3  
X0, X1, X2, X3  
HT81 Series  
Notes:  
Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject  
to change without notice.  
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.  
226  
© July 2020  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY