Total Power:  
200ꢀ-ꢀ300W  
Input Voltage: 36ꢀ-ꢀ75Vdc  
ElectricalꢀSpecifications  
Output  
Outputꢀsetpointꢀaccuracy:  
See table  
Lineꢀregulation:  
Lowꢀlineꢀtoꢀhighꢀlineꢀ  
Seeꢀtable  
Special Features  
Loadꢀregulation:  
Total error band  
(includingꢀsetpoint,ꢀline,ꢀ  
loadꢀandꢀtemperature):  
Minimumꢀload:  
Fullꢀloadꢀtoꢀmin.ꢀloadꢀ  
IBC25AET4812ꢀ  
IBC20AES4812ꢀ  
IBC17AEW4812ꢀ  
Seeꢀtable  
9.70ꢀ-ꢀ13.40ꢀVdc  
11.52ꢀ-ꢀ12.48ꢀVdc  
11.40ꢀ-ꢀ12.60ꢀVdc  
0ꢀA  
•ꢀ 48ꢀVꢀinputꢀwithꢀisolatedꢀ12ꢀVꢀ  
output  
•ꢀ Ultra-highꢀefficiency,ꢀ95.5%ꢀ  
12ꢀVꢀ@ꢀ25ꢀA  
Overshoot:  
Atꢀturnꢀonꢀandꢀturn-offꢀ  
None  
•ꢀ Unprecedentedꢀusableꢀ  
output power levels  
•ꢀ Highꢀpowerꢀdensityꢀ  
(362 W/in3) open-frame  
Undershoot:  
Rippleꢀandꢀnoise:  
5ꢀ-ꢀ20ꢀMHz  
None  
60ꢀmVꢀpk-pkꢀtyp.  
20ꢀmVꢀrmsꢀtyp.  
(Seeꢀnoteꢀ2)ꢀ  
technology  
•ꢀ Wideꢀoperatingꢀambientꢀ  
temperatureꢀrange  
Input  
Inputꢀvoltageꢀrange:  
See table  
•ꢀ Industryꢀstandardꢀeighth-  
brick footprint and pinout  
•ꢀ Lowꢀprofile,ꢀ0.40”ꢀ(10.2ꢀmm)  
•ꢀ Meetsꢀbasicꢀinsulationꢀ  
requirementsꢀofꢀEN60950-1  
•ꢀ RemoteꢀON/OFFꢀandꢀover-  
temperature protection  
•ꢀ AvailableꢀRoHSꢀcompliant  
•ꢀ2ꢀyearꢀwarranty  
Inputꢀcurrent:  
Inputꢀcurrentꢀ(max.):  
RemoteꢀOFFꢀ  
(Seeꢀnoteꢀ1)ꢀ  
IBC25AET4812ꢀ  
IBC20AES4812ꢀ  
IBC17AEW4812ꢀ  
6ꢀmAꢀtyp.  
6.9ꢀAꢀmax.ꢀ@ꢀloꢀmax.  
andꢀVinꢀ=ꢀmin.ꢀrated  
550ꢀmAꢀ(pk-pk)  
Inputꢀreflectedꢀripple:  
(Seeꢀnoteꢀ4)  
230ꢀmAꢀ(pk-pk)  
230ꢀmAꢀ(pk-pk)  
(see note 6)  
Openꢀcollectorꢀref.ꢀto-ꢀinput  
RemoteꢀON/Off:  
Logicꢀcompatiblity:  
On  
>2.4ꢀVdc  
<0.4ꢀVdc  
40ꢀV  
38ꢀV  
35.2ꢀV  
34ꢀV  
OFF  
Undervoltageꢀlockout:  
IBC25AET4812:  
IBC20AES4812:  
IBC17AEW4812:  
Power-upꢀ  
Power-downꢀ  
Powerꢀupꢀ  
Powerꢀdownꢀ  
Safety  
ꢀ•ꢀUL/cULꢀ60950-1,ꢀ1stꢀEdition  
Startup time (seeꢀnoteꢀ3):  
Power-upꢀ  
RemoteꢀON/OFFꢀ  
15ꢀms  
5ꢀms  
ꢀ•ꢀENꢀ60950-1ꢀVDE  
Embedded Power for  
Business-Critical Continuity  
Rev.11.25.08_136  
Eighth-Brick IBC Series  
2 of 3  
EMCꢀCharateristics  
Immunity:  
ESDꢀairꢀenclosure:  
Inputꢀtransients:  
EN61000-4-2ꢀ8ꢀkV,ꢀ6ꢀkVꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ(Airꢀcontact)  
IBC25AET4812ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ60ꢀV.ꢀ100ꢀms  
IBC20AES4812ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ60ꢀV.ꢀ100ꢀms  
IBC17AEW4812ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ100ꢀV.ꢀ100ꢀms  
EnvironmentalꢀSpecifications  
ꢀ-40ꢀ°Cꢀtoꢀ+85ꢀ°C  
Thermalꢀ  
Operatingꢀambientꢀtemperatureꢀ  
performance: Non-operatingꢀ ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ-55ꢀ°Cꢀtoꢀ+125ꢀ°C  
GeneralꢀSpecifications  
Efficiency:  
See table  
Input/outputꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ2250ꢀVdc  
Fixedꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ600ꢀkHzꢀtyp.  
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀEN60950-1ꢀVDEꢀ  
Protection  
Basicꢀinsulation:  
Switchingꢀfrequency:  
Approvalsꢀandꢀ  
Short-circuit:  
Overvoltage: (Seeꢀnoteꢀ9)ꢀ  
Thermal:  
Hiccup  
Non-latching  
125ꢀ°Cꢀhotꢀspot  
standardsꢀ(seeꢀnoteꢀ5): ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀUL/cUL60950-1  
Materialꢀflammability:  
Weight:  
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀUL94V-0  
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ33ꢀgꢀ(1.16ꢀoz)  
TelcordiaꢀTechꢀSR-332ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ5,500,000ꢀhours  
MTBFꢀ  
Representativeꢀmodel: 48ꢀVin,ꢀ40ꢀ°C,ꢀ50%ꢀload  
groundꢀbenign  
Allꢀspecificationsꢀareꢀtypicalꢀatꢀnominalꢀinput,ꢀfullꢀloadꢀatꢀ25°ꢀCꢀunlessꢀotherwiseꢀstated.  
OrderingꢀInformation  
Regulation2 (typical)  
Output  
Power  
(Max.)  
Output  
Current  
(Min.)  
Input  
Voltage  
Output  
Voltage  
Output Current  
(Max.)  
Efficiency  
(Typ.)  
Model Number  
Set Point  
Accuracyꢀ%  
Lineꢀ%  
Loadꢀ%  
300ꢀW  
240ꢀW  
200ꢀW  
42ꢀ-ꢀ53ꢀVdc  
42ꢀ-ꢀ53ꢀVdc  
36ꢀ-ꢀ75ꢀVdc  
12ꢀV  
12ꢀV  
12ꢀV  
0ꢀA  
0ꢀA  
0ꢀA  
25ꢀA  
20ꢀA  
17ꢀA  
95.5%  
94.5%  
94.0%  
---  
+10,ꢀ-12.5%  
±0.3%  
±1.5%  
-2/-1.5%  
-3/+2%  
IBC25AET4812J  
IBC20AES4812J  
IBC17AEW4812J  
±0.25%  
±0.25%  
±1.0%  
CAUTION:ꢀHazardousꢀinternalꢀvoltagesꢀandꢀhighꢀtemperatures.  
Ensureꢀthatꢀunitꢀisꢀnotꢀuserꢀaccessible.  
PartꢀNumberꢀSystemꢀwithꢀOptions  
Rated Output  
Current  
Form Factor  
Input Voltage Type  
Input  
Output  
Remote ON/  
Module Height  
Pin Length  
RoHS Compliance(7, 8)  
Product Family  
Voltage  
Voltage  
OFF Logic  
Options  
IBC  
17A  
E
W
48  
12  
-
R
A
N
J
Aꢀ=ꢀOpen-frameꢀ  
0.40ꢀinꢀ(10.2ꢀ  
mm)  
Eꢀ=ꢀOpen-rame,ꢀ  
0.45ꢀinꢀ(11.4ꢀ  
mm)  
Jꢀ=ꢀPb-freeꢀ  
(RoHSꢀ6/6ꢀ  
compliant)  
Yꢀ=ꢀRoHSꢀ5/6ꢀ  
compliant  
17ꢀAꢀ=ꢀ  
17ꢀAmpsꢀetc.  
48ꢀ=ꢀ48ꢀV 12ꢀ=ꢀ12ꢀV  
Blankꢀ=ꢀ  
Positive  
Rꢀ=ꢀNegativeꢀ  
(See Note 6)  
Blankꢀ=ꢀ0.188ꢀ”ꢀ  
(4.78ꢀmm)  
Nꢀ=ꢀ0.145ꢀ”ꢀ  
(3.68ꢀmm)  
Kꢀ=ꢀ0.110ꢀ”ꢀ  
(2.79ꢀmm)  
Eꢀ=ꢀEighth-  
Brick  
Qꢀ=ꢀQuarter-  
brick  
Sꢀ=ꢀSixteenth- Nꢀ=ꢀNarrowꢀTelecomꢀ  
brick  
Tꢀ=ꢀNarrowꢀInputꢀ  
FixedꢀRatio  
Sꢀ=ꢀNarrowꢀInputꢀ  
Semi-reguated  
IBC Intermediate  
Bus Converter  
2nd Generation  
FixedꢀRatio  
Wꢀ=ꢀWideꢀTelecomꢀ  
Semi-reguated  
Notes  
1ꢀ Recommendedꢀinputꢀfusingꢀisꢀaꢀ20ꢀAꢀHRCꢀ250ꢀVꢀratedꢀfuse.  
2ꢀ Measuredꢀwithꢀexternalꢀfilter.ꢀꢀSeeꢀApplicationꢀNoteꢀ182ꢀforꢀdetails.  
3ꢀ Start-upꢀintoꢀresistiveꢀload.  
4ꢀ PeakꢀtoꢀpeakꢀmeasuredꢀwithoutꢀexternalꢀPiꢀfilter.ꢀꢀSignificantꢀreductionꢀ  
possibleꢀwithꢀexternalꢀfilter.ꢀꢀSeeꢀApplicationꢀNoteꢀ182ꢀforꢀdetails.  
5ꢀ Thisꢀproductꢀisꢀonlyꢀforꢀinclusionꢀbyꢀprofessionalꢀinstallersꢀwithinꢀotherꢀ  
equipmentꢀandꢀmustꢀnotꢀbeꢀoperatedꢀasꢀaꢀstandꢀaloneꢀproduct.  
6ꢀ Active-lowꢀremoteꢀON/OFFꢀoptionꢀisꢀalsoꢀavailable.ꢀꢀPleaseꢀaddꢀtheꢀsuffixꢀ‘-R’ꢀ  
toꢀtheꢀpartꢀnumber,ꢀe.g.ꢀIBC17AEW4812-RAJ.  
7ꢀ TSEꢀRoHSꢀ5/6ꢀ(nonꢀPb-free)ꢀcompliantꢀversionsꢀmayꢀbeꢀavailableꢀonꢀspecialꢀ  
request,ꢀpleaseꢀcontactꢀyourꢀlocalꢀsalesꢀrepresentativeꢀforꢀdetails.  
8ꢀ NOTICE:ꢀSomeꢀmodelsꢀdoꢀnotꢀsupportꢀallꢀoptions.ꢀPleaseꢀcontactꢀyourꢀlocalꢀ  
Salesꢀrepresentativeꢀorꢀuseꢀtheꢀon-lineꢀmodelꢀnumberꢀsearchꢀtoolꢀatꢀhttp://  
www.powerconversion.comꢀtoꢀfindꢀaꢀsuitableꢀalternative.  
Embedded Power for  
Business-Critical Continuity  
Rev.11.25.08_136  
Eighth-Brick IBC Series  
3 of 3  
MechanicalꢀDrawing  
Americas  
5810ꢀVanꢀAllenꢀWay  
Carlsbad,ꢀCAꢀ92008  
USA  
2.30  
[58.4]  
Telephone:ꢀ+1ꢀ760ꢀ930ꢀ4600  
Facsimile:ꢀꢀ +1ꢀ760ꢀ930ꢀ0698  
2.000  
[50.80]  
0.1450.020  
[3.680.51]  
Europe (UK)  
Waterfront Business Park  
MerryꢀHill,ꢀDudley  
WestꢀMidlands,ꢀDY5ꢀ1LX  
UnitedꢀKingdom  
Telephone:ꢀ+44ꢀ(0)ꢀ1384ꢀ842ꢀ211  
Facsimile:ꢀ +44ꢀ(0)ꢀ1384ꢀ843ꢀ355  
1
2
3
5
4
0.300  
[7.62]  
0.90  
[22.9]  
0.300  
[7.62]  
Asia (HK)  
0.45  
[11.4]  
14/F,ꢀLuꢀPlaza  
2ꢀWingꢀYipꢀStreet  
KwunꢀTong,ꢀKowloon  
HongꢀKong  
Refer to Part  
Numbering Options  
Table for Module Height  
Telephone:ꢀ+852ꢀ2176ꢀ3333  
Facsimile:ꢀ +852ꢀ2176ꢀ3888  
Refer to Part  
Numbering Options  
Table for Pin Length  
0.04 [1.0]  
MIN  
Forꢀglobalꢀcontact,ꢀvisit:  
www.powerconversion.com  
ø0.093 [2.36]  
ø0.062 [1.57]  
0.060 [1.52]  
techsupport.embeddedpower  
@emerson.com  
0.040 [1.02]  
Whileꢀeveryꢀprecautionꢀhasꢀbeenꢀtakenꢀtoꢀensureꢀ  
accuracyꢀandꢀcompletenessꢀinꢀthisꢀliterature,ꢀEmersonꢀ  
NetworkꢀPowerꢀassumesꢀnoꢀresponsibility,ꢀandꢀdisclaimsꢀ  
allꢀliabilityꢀforꢀdamagesꢀresultingꢀfromꢀuseꢀofꢀthisꢀ  
informationꢀorꢀforꢀanyꢀerrorsꢀorꢀomissions.  
Solder venting  
feature  
ø0.092 [2.34]  
ø0.122 [3.10]  
Emerson Network Power.  
Theꢀglobalꢀleaderꢀinꢀenabling  
business-criticalꢀcontinuity.  
Dimensions in Inches (mm)  
Pin Connections  
Pin Number Function  
Tolerances (unless otherwise specified)  
x.xx 0.02 (x.x 0.5)  
x.xxx 0.010 (x.xx 0.25)  
ACꢀPower  
1
2
3
4
5
+Vin  
Connectivity  
RemoteꢀON/OFF  
-Vin  
DCꢀPower  
-Vout  
EmbeddedꢀComputing  
Embedded Power  
Monitoring  
+Vout  
OutsideꢀPlant  
PowerꢀSwitchingꢀ&ꢀControls  
PrecisionꢀCooling  
Racksꢀ&ꢀIntegratedꢀCabinets  
Services  
SurgeꢀProtection  
EmersonNetworkPower.com  
EmersonꢀNetworkꢀPowerꢀandꢀtheꢀEmersonꢀ  
NetworkꢀPowerꢀlogoꢀareꢀtrademarksꢀandꢀ  
serviceꢀmarksꢀofꢀEmersonꢀElectricꢀCo.ꢀꢀ  
©2008ꢀEmersonꢀElectricꢀCo.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY