NFS110 Series  
1 of 5  
NFS110 Series  
Single & Quad output  
Total Power:  
80 - 110 W  
Input Voltage: 85 - 264 Vac  
120 - 370 Vdc  
# of Outputs: Single, quad  
Electrical Specifications  
Special Features  
• 7.0 x 4.25 x 1.8 inch package  
• Overvoltage and short circuit  
protection  
• 110 W with 20 CFM  
• Adjustable outputs  
• EN55022, EN55011 conducted  
emissions level B  
• UL, VDE and CSA safety  
approvals  
Output  
Voltage adjustability:  
+5.1 V o/p on multi’s  
5.1 V single output  
12 V single output  
15 V single output  
24 V single output  
3.0%  
3.0%  
12 - 14 V  
15 - 18 V  
24 - 30 V  
Line regulation:  
LL to HL, FL  
±0.1% max.  
All outputs on all units  
Overshoot/undershoot:  
Temperature coefficient:  
Overvoltage protection:  
At turn-on  
All outputs  
0%  
• CE mark  
• Available RoHS compliant  
• 2 year warranty  
±0.02%/°C  
Multi o/p 5.1 V only  
5.1 V single output  
12 V single output  
15 V single output  
24 V single output  
6.25 V ± 0.75 V  
6.25 V ± 0.75 V  
15.75 V ± 1.0 V  
22 V ± 1.5 V  
33 V ± 2.5 V  
Output power limit:  
Primary power limited  
Pin max. 160 W  
Pout min. 110 W  
Minimum output current:  
Short circuit protection:  
(See Note 13)  
0 A  
Safety  
Burst mode operation  
• VDE0805/EN60950/  
• IEC950/IEC1010  
Input  
Input voltage range:  
85 - 264 Vac  
120 - 370 Vdc  
File No. 10401-3336-0213  
• Licence No. 4001467 7  
• UL1950 File No. E132002  
• CSA C22.2 No. 950  
File No. LR41062C  
Input frequency range:  
Input surge current:  
47 - 440 Hz  
35 A  
230 Vac  
Safety ground leakage current:  
110 Vac, 50 Hz  
230 Vac, 50 Hz  
0.2 mA, max.  
0.4 mA, max.  
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated  
Embedded Power for  
Business-Critical Continuity  
Rev. 11.2.09_69  
NFS110 Series  
2 of 5  
EMC Characteristics  
Conducted emissions:  
Radiated emissions:  
ESD air:  
EN55022, FCC part 15  
EN55022, FCC part 15  
EN61000-4-2, level 3  
EN61000-4-2, level 4  
EN61000-4-3, level 3  
EN61000-4-4, level 3  
EN61000-4-5, level 3  
EN61000-4-6, level 3  
Level B  
Level A  
Perf. criteria 1  
Perf. criteria 1  
Perf. criteria 1  
Perf. criteria 1  
Perf. criteria 2  
Perf. criteria 1  
ESD contact:  
Surge:  
Fast transients:  
Radiated immunity:  
Conducted immunity:  
General Specifications  
Hold-up time:  
110 Vac @ 80 W  
110 Vac @ 110 W  
230 Vac @ 80 W  
230 Vac @ 100 W  
35 ms  
17 ms  
140 ms  
100 ms  
Efficiency:  
Multiple outputs  
+5.1 V single  
12 V and 15 V singles  
24 V single  
70% typical  
70% typical  
72% typical  
75% typical  
Isolation voltage:  
Input/output  
Input/chassis  
3000 Vac  
1500 Vac  
Approvals and standards:  
(see note 12)  
VDE0805, EN60950, IEC950, IEC1010, UL1950, CSA C22.2 No. 950  
Weight:  
Singles  
Multiple outputs  
550 g (19.4 oz)  
600 g (21.2 oz)  
MTBF (@25 ºC):  
MIL-HDBK-217E  
125,000 hours min.  
Environmental Specifications  
Thermal performance:  
Operating ambient  
0° C to +70 °C  
(See notes 9, 10)  
Non-operating  
-40 °C to +85 °C  
80 W  
0 °C to 50 °C convection cooled  
+50 °C to +70 °C, convection cooled Derate 2 W/°C  
0 °C to +50 °C, 20 CFM forced air  
+50 °C to +70 °C, 20CFM forced air  
110 W  
Derate 2.75 W/°C  
Peak, 0 °C to +50 °C, max. 60 seconds 110W  
Relative humidity:  
Altitude:  
Non-condensing  
Operating  
5 to 95% RH  
10,000 feet max.  
40,000 feet max.  
2.4 G rms peak  
Non-operating  
5 - 500 Hz  
Vibration:  
(See Note 11)  
Embedded Power for  
Business-Critical Continuity  
Rev. 11.2.09_69  
NFS110 Series  
3 of 5  
Ordering Information  
Output Currents  
Peak (2)  
20 A  
Output  
Total  
Regulation (5)  
Ripple (4)  
Model Numbers (13, 15, F)  
Max (1)  
8 A  
Fan (3)  
10 A  
5 A  
Voltage  
NFS110-7601PJ (14)  
+5.1 V  
+12 V  
50 mV  
120 mV  
120 mV  
50 mV  
± 2.0%  
± 3.0%  
± 3.0%  
± 3.0%  
± 2.0%  
+10/–5.0%  
± 3.0%  
± 3.0%  
± 2.0%  
± 4.0%  
± 3.0%  
± 3.0%  
± 2.0%  
± 2.0%  
± 2.0%  
4.5 A  
0.5 A  
0.5 A  
8 A  
9 A  
–12 V  
1.5 A  
1.5 A  
20 A  
1 A  
–5 V  
1 A  
NFS110-7602PJ (6, 14)  
NFS110-7604PJ (14)  
+5.1 V (I  
)
10 A  
4.5 A  
5 A  
50 mV  
A
+24 V (I ) (6)  
3.5 A  
4.5 A  
0.5 A  
8 A  
4.5 A  
9 A  
240 mV  
120 mV  
120 mV  
50 mV  
B
+12 V  
–12 V  
+5.1 V  
15 V  
1.5 A  
20 A  
1 A  
10 A  
5 A  
4 A  
7.5 A  
1.5 A  
1.5 A  
9 A  
150 mV  
150 mV  
50 mV  
-15 V  
-5 V  
0.5 A  
0.5 A  
7 A  
1 A  
1 A  
NFS110-7612J (7,8)  
NFS110-7615J (7,8)  
NFS110-7624J (7,8)  
12 V  
9 A  
120 mV  
150 mV  
240 mV  
15 V  
5 A  
7.3 A  
4.5 A  
7.3 A  
4.5 A  
24 V  
3.5 A  
Notes  
Transient Response  
NFS110-7601PJ  
1
2
Convection cooled, 80 W maximum.  
Peak outputs lasting less than 60 seconds with duty cycle less than 10%. Total  
peak power must not exceed 110 W.  
+5.1 V (7.5 A to 10 A)  
+12 V (2.5 A to 5 A)  
-12 V (0.5 A to 1 A)  
-5 V (0.5 A to 1 A)  
150 mV peak, 1 ms recovery  
100 mV peak, 0.5 ms recovery  
100 mV peak, 0.5 ms recovery  
100 mV peak, 0.5 ms recovery  
3
4
Forced air, 20 CFM at 1 atmosphere, 110 W maximum.  
Figure is peak-to-peak. Output ripple is measured across a 50 MHz bandwidth  
using a 12 inch twisted pair terminated with a 47 µF capacitor.  
Total regulation is defined as the static output regulation at 25 °C, including  
initial tolerance, line voltage within stated limits and output voltages adjusted  
to their factory settings.  
5
NFS110-7602PJ  
NFS110-7604PJ  
+5.1 V (7.5 A to 10 A)  
+24 V (1.5 A to 3 A)  
+12 V (2.5 A to 5 A)  
-12 V (0.5 A to 1 A)  
150 mV peak, 1 ms recovery  
300 mV peak, 1 ms recovery  
100 mV peak, 0.5 ms recovery  
100 mV peak, 0.5 ms recovery  
6
To achieve stated regulation on the 24 V output on the NFS110-7602PJ, the  
following load condition must be true: I / I ≤ 5, where:  
A
B
I
I
= +5.1 V output current, and  
= +24 V output current  
A
B
The +24 V output will maintain ±5.0% regulation under the following  
additional condition: I ≤ 5 A.  
+5.1 V (7.5 A to 10 A)  
+15 V (2.5 A to 5 A)  
-15 V (0.5 A to 1 A)  
-5 V (0.5 A to 1 A)  
150 mV peak, 1 ms recovery  
100 mV peak, 0.5 ms recovery  
100 mV peak, 0.5 ms recovery  
100 mV peak, 0.5 ms recovery  
A
7
Single output models have floating outputs which may be referenced as  
either positive or negative. Higher voltage supplies may be adjusted over a  
wide output voltage range, as long as the total output power does not exceed  
80 Watts (natural convection) or 110 Watts (forced air).  
8
9
Power fail detect not available on single output models.  
Derating curve is application specific for ambient temperatures >50 °C,  
for optimum reliability no part of the heatsink should exceed 90 ºC and no  
semiconductor case temperature should exceed 100 ºC.  
NFS110-7605J  
NFS110-7612J:  
NFS110-7615J  
NFS110-7624J  
+5.1 V (10 A to 20 A)  
+12 V (4.5 A to 9 A)  
+15 V (3.65 A to 7.3 A)  
+24 V (2.25 A to 4.5 A)  
250 mV peak, 1 ms recovery  
360 mV peak, 1 ms recovery  
450 mV peak, 1 ms recovery  
720 mV peak, 1 ms recovery  
10 Caution: Allow a minimum of 1 second after disconnecting the power when  
making thermal measurements.  
11 Three orthogonal axes, random vibration, 10 minute test for each axis.  
12 This product is only for inclusion by professional installers within other  
equipment and must not be operated as a stand alone product.  
13 Recommend a minimum load of 11 W to achieve the design MTBF. See the  
derating curve on page 4.  
14 Power failure detec is optional by including the suffix “P” to the model  
number.  
15 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.  
16 NOTICE: Some models do not support all options. Please contact your  
local Emerson Network Power representative or use the on-line model  
number search tool at http://www.PowerConversion.com to find a suitable  
alternative.  
Embedded Power for  
Business-Critical Continuity  
Rev. 11.2.09_69  
NFS110 Series  
4 of 5  
OPTIONAL POWER FAIL DETECT TIMING DIAGRAM  
Power fail detect signal (Note 8)  
50ms ≤ T1 ≤ 200ms  
T2 will vary with line and load  
T3 ≥ 3ms  
Pout: 110W  
PFD output is an open collector which  
will sink ≤ 40mA in the low state.  
AC (J1) mating connector  
AC INPUT  
Molex 09-50-3051 or Molex 09-91-0500 mating connector with 2478  
or equivalent crimp terminals.  
4.75V  
4.75V  
5V OUTPUT  
PFD SIGNAL  
HIGH  
3.5V MIN  
T3  
DC (J2) mating connector  
LOW  
Molex 09-50-3131 or Molex 09-91-1300 mating connector with 2478  
or equivalent crimp terminals.  
0-0.4 MAX  
T2  
T1  
0.475  
0.010  
(12.07)  
DERATING CURVE (See Notes 9, 10)  
1.80 (45.72) MAX  
1.00 0.005  
(25.4)  
Output Power (Watts)  
110W  
80W  
20 CFM FORCED AIR COOLING  
6-32 UNC  
(4PL)  
0.050 0.020  
(1.27)  
1.55 0.005  
(39.37)  
3.35 0.015 (85.09)  
PIN 1  
Voltage Adjust  
Optional  
NATURAL  
CONVECTION  
COOLING  
Power Fail  
J2  
55W  
40W  
Detect Circuit  
(Key = Pin 2)  
4.250  
0.020  
(107.95)  
T1  
3.750  
Pin 1  
0.005  
(95.25)  
PIN 1  
L1  
11W  
0W  
11W MINIMUM LOAD REQUIRED AT 230VAC  
0.156  
J1  
DIA. HOLE  
(4PL)  
0C  
10C  
20C  
30C  
40C  
50C  
60C  
70C  
C6  
F1  
5A, 250 VAC  
Pin Connections  
0.250  
0.010  
(6.35)  
6.50 0.005 (165.1)  
7.00 0.020 (177.8)  
J1  
-7601PJ  
-7602 P  
-7604PJ  
Singles  
Pin 1  
Pin 2  
Pin 3  
J2  
AC Ground  
AC Neutral  
AC Line  
AC Ground AC Ground AC Ground  
0.250  
0.010  
(6.35)  
ALL DIMENSIONS IN INCHES (mm)  
AC Neutral  
AC Line  
AC Neutral AC Neutral  
AC Line  
AC Line  
Mechanical Notes:  
A
B
C
D
E
Metallic or non-metallic stand-offs (maximum diameter 5.4mm) can be used in all four mounting holes  
without effecting safety approval.  
The ground pad of the mounting hole near J1, allows system grounding through a metal stand-off to  
the system chassis.  
The heat sink is grounded, and allows system grounding by mechanical connection to the system  
chassis.  
The supply must be mechanically supported using the PCB mounting holes and may be additionally  
supported by the heatsink mounting holes.  
It is always advisable to attach the power supply heat sink to another thermal dissipator (such as a  
chassis or finned heatsink etc). The resulting decrease in heat sink mounted component temperatures  
will improve power supply lifetime.  
A standard L-bracket and cover is available for mounting which contains all screws, connectors and  
necessary mounting hardware. The kit is available, order part number “NFS110CJ”.  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Pin 9  
Pin 10  
Pin 11  
Pin 12  
Pin 13  
+5.1 V  
+5.1 V  
+5.1 V  
Return  
Return  
Return  
Return  
+12 V  
+12 V  
PFD  
+5.1 V  
+5.1 V  
+5.1 V  
Return  
Return  
Return  
Return  
+12 V  
+12 V  
PFD  
+5.1 V  
+5.1 V  
+5.1 V  
Return  
Return  
Return  
Return  
+15 V  
+15 V  
PFD  
V
out  
V
out  
V
out  
Return  
Return  
Return  
Return  
F
V
out  
V
out  
N/C  
-12 V  
-12 V  
-15 V  
N/C  
Removed for Key  
-5 V  
+24 V  
-5 V  
N/C  
N/C = no connection  
Embedded Power for  
Business-Critical Continuity  
Rev. 11.2.09_69  
NFS110 Series  
5 of 5  
Americas  
5810 Van Allen Way  
Carlsbad, CA 92008  
USA  
Telephone: +1 760 930 4600  
Facsimile: +1 760 930 0698  
Europe (UK)  
Waterfront Business Park  
Merry Hill, Dudley  
West Midlands, DY5 1LX  
United Kingdom  
Telephone: +44 (0) 1384 842 211  
Facsimile: +44 (0) 1384 843 355  
Asia (HK)  
14/F, Lu Plaza  
2 Wing Yip Street  
Kwun Tong, Kowloon  
Hong Kong  
Telephone: +852 2176 3333  
Facsimile: +852 2176 3888  
For global contact, visit:  
www.PowerConversion.com  
techsupport.embeddedpower  
@emerson.com  
While every precaution has been taken to ensure  
accuracy and completeness in this literature, Emerson  
Network Power assumes no responsibility, and disclaims  
all liability for damages resulting from use of this  
information or for any errors or omissions.  
Emerson Network Power.  
The global leader in enabling  
business-critical continuity.  
AC Power  
Connectivity  
DC Power  
Embedded Computing  
Embedded Power  
Monitoring  
Outside Plant  
Power Switching & Controls  
Precision Cooling  
Racks & Integrated Cabinets  
Services  
Surge Protection  
EmersonNetworkPower.com  
Emerson Network Power and the Emerson  
Network Power logo are trademarks and  
service marks of Emerson Electric Co.  
©2009 Emerson Electric Co.  

相关型号:

NFS110-7601P

80-110W AC/DC Universal Input Switch Mode Power Supplies
ARTESYN

NFS110-7601PJ

110 W universal input ac-dc power supply
EMERSON-NETWO

NFS110-7602P

80-110W AC/DC Universal Input Switch Mode Power Supplies
ARTESYN

NFS110-7602PJ

110 W universal input ac-dc power supply
EMERSON-NETWO

NFS110-7604P

80-110W AC/DC Universal Input Switch Mode Power Supplies
ARTESYN

NFS110-7604PJ

Single & quad output
EMERSON-NETWO

NFS110-7605

80-110W AC/DC Universal Input Switch Mode Power Supplies
ARTESYN

NFS110-7605J

110 W universal input ac-dc power supply
EMERSON-NETWO

NFS110-7612

80-110W AC/DC Universal Input Switch Mode Power Supplies
ARTESYN

NFS110-7612J

Single & quad output
EMERSON-NETWO

NFS110-7615

80-110W AC/DC Universal Input Switch Mode Power Supplies
ARTESYN

NFS110-7615J

Single & quad output
EMERSON-NETWO