B84143G0150R110 [EPCOS]
EMC filters; EMC滤波器型号: | B84143G0150R110 |
厂家: | EPCOS |
描述: | EMC filters |
文件: | 总10页 (文件大小:198K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
EMC filters
3-line filters
for converters and power electronics
Rated current 8 to 220 A
Series/Type:
B84143G*R110
Date:
January 2006
EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the
information contained therein without EPCOS’ prior express consent is prohibited.
3-line filters
B84143G*R110
for converters and power electronics
Power line filters for 3-phase systems
Rated voltage 520/300 V AC, 50/60 Hz
Rated current 8 to 220 A
Alternative version
■ꢀ Series B84143A*R105
offers a low-cost solution.
Construction
■ꢀ 3-line filter
■ꢀ Metal case
■ꢀ Book size
Features
■ꢀ High insertion loss
■ꢀ Optimized leakage current
■ꢀ Space saving by optimized footprint
■ꢀ Litz wires on the load side reduce mounting time
■ꢀ Low weight
■ꢀ Degree of protection: IP 201)
■ꢀ Optimized for long motor cables and operation
under full load
■ꢀ Design complies with
EN 133200, UL 1283, CSA C22.2 No.8
■ꢀ UL approval
Applications
■ꢀ Frequency converters for motor drives, e.g.
elevators, pumps, traction systems, conveyor systems,
HVAC systems (heating, ventilation and air conditioning)
■ꢀ Wind farms
■ꢀ Power supplies
Terminals
■ꢀ Line side: Finger-safe terminal blocks
■ꢀ Load side: Litz wires
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current, rated temperature,
climatic category, date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
1) To IEC 60529
Please read Cautions and warnings and
Important notes at the end of this document.
2
01/06
3-line filters
B84143G*R110
for converters and power electronics
Typical circuit diagrams
Filters for 8 … 25 A
LINE
L1
LOAD
L1’
L2
L3
L2’
L3’
SSB1286-Z
Filters for 36 … 220 A
LINE
L1
LOAD
L1’
L2
L3
L2’
L3’
SSB1287-8
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06
3-line filters
B84143G*R110
for converters and power electronics
Technical data and measuring conditions
Rated voltage VR
Rated current IR
Test voltage Vtest
520/300 V AC, 50/60 Hz
Referred to 40 °C ambient temperature
1770 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Overload capability (thermal)
1.5 · IR for 3 min per hour or
2.5 · IR for 30 s per hour
Leakage current Ileak
Climatic category (IEC 60068-1)
Approvals
At 480 V AC, 50 Hz
25/100/21 (–25 °C/+100 °C/21 days damp heat test)
UL 1283 for 480 V AC. For 520 V AC pending.
Characteristics and ordering codes
IR
Appro•
vals
(480 V)
VR
AC
Terminal cross section Ileak
Rtyp
Approx. Ordering code
weight
Line side:
terminal
blocks
Load side:
litz
wires
mm2
V
mm2
mA
mΩꢀ
40
kg
A
520/300
8
4
4
1.5
2.5
2.5
6.0
10
<
<
<
6
1.3
1.3
1.3
2.8
3.3
4.4
4.9
7.5
8.0
B84143G0008R110 ×ꢀ
B84143G0020R110 ×ꢀ
B84143G0025R110
20
25
6
6
10
4
10
–
36
6
< 16
< 16
< 16
< 16
< 16
< 16
< 16
5.2
2.4
1.8
1.2
1.0
0.7
B84143G0036R110 ×ꢀ
B84143G0050R110 ×ꢀ
B84143G0066R110 ×ꢀ
B84143G0090R110 ×ꢀ
B84143G0120R110 ×ꢀ
B84143G0150R110 ×ꢀ
B84143G0220R110 ×ꢀ
50
16
25
25
50
50
95
66
16
90
25
120
150
220
35
35
70
0.4 11.5
×ꢀ= approval granted
Please read Cautions and warnings and
Important notes at the end of this document.
4
01/06
3-line filters
B84143G*R110
for converters and power electronics
Dimensional drawings
B84143G0008R110, B84143G0020R110, B84143G0025R110 (8 A to 25 A)
300 10
Litz wire
50
200
PE M6 x 24
Wire end ferrule
Litz wire markings
230
215 0.5
Terminal blocks 4 mm 2
Tightening torque 0.6 ... 0.8 Nm
L1
L1’
L2’
L3’
PE
L2
L3
PE
Marking
LINE LOAD
SSB2188-F-E
B84143G0036R110 (36 A)
60
250
400 10
Litz wire
Wire end ferrule
Litz wire markings
PE M6 x 24
280
Terminal blocks 6 mm 2
Tightening torque 1.5 ... 1.8 Nm
265 0.5
L1
L2
L3
PE
L1’
L2’
L3’
PE
Marking
LINE LOAD
SSB2190-R-E
Please read Cautions and warnings and
Important notes at the end of this document.
5
01/06
3-line filters
B84143G*R110
for converters and power electronics
B84143G0050R110 (50 A)
60
300
500 10
Litz wire
PE M6 x 24
Wire end ferrule
Litz wire markings
330
Terminal blocks 16 mm 2
Tightening torque 2 ... 2.3 Nm
315 0.5
L1
L1’
L2’
L3’
PE
L2
L3
PE
Marking
LINE LOAD
SSB2191-Z-E
B84143G0066R110, B84143G0090R110 (66 A and 90 A)
80
300
500 10
Litz wire
60
PE M10 x 39
Wire end ferrule
Litz wire markings
330
Terminal blocks 25 mm 2
Tightening torque 4 ... 4.5 Nm
315 0.5
L1
L2
L3
PE
L1’
L2’
L3’
PE
Marking
LINE LOAD
SSB2192-8-E
Please read Cautions and warnings and
Important notes at the end of this document.
6
01/06
3-line filters
B84143G*R110
for converters and power electronics
B84143G0120R110, B84143G0150R110 (120 A and 150 A)
Wire end ferrule
500 10
Litz wire
90
350
65
PE M10 x 39
Litz wire markings
Terminal
380
blocks 50 mm 2
Tightening
torque 6 ... 8 Nm
365 0.5
L1
L2
L3
PE
L1’
L2’
L3’
PE
Marking
LINE LOAD
SSB2194-P-E
B84143G0220R110 (220 A)
Wire end ferrule
400
500 10
Litz wire
110
80
PE M10 x 39
Litz wire markings
Terminal
430
blocks 95 mm2
Tightening
415 0.5
torque15 ... 20 Nm
L1
L2
L3
PE
L1’
L2’
L3’
PE
Marking
LINE LOAD
SSB2196-6-E
Please read Cautions and warnings and
Important notes at the end of this document.
7
01/06
3-line filters
B84143G*R110
for converters and power electronics
Insertion loss (typical values at Z = 50 Ω)
unsymmetrical, adjacent branches terminated
common mode, all branches in parallel (asymmetrical)
differential mode (symmetrical)
Filters for 8 A
120
Filters for 20 and 25 A
SSB1289-P
SSB1288-G
120
dB
B84143G0020R110
B84143G0025R110
B84143G0008R110
dB
α
α
100
100
80
60
40
20
0
80
60
40
20
0
104
105
106
107 Hz 108
f
104
105
106
107 Hz 108
f
Filters for 36 … 220 A
120
SSB1290-S
B84143G0036 ... G0220R110
dB
α
100
80
60
40
20
0
104
105
106
107 Hz 108
f
Please read Cautions and warnings and
Important notes at the end of this document.
8
01/06
EMC filters
Cautions and warnings
Important information
Please read all safety and warning notes carefully before installing the EMC filter and putting it into
operation (see
). The same applies to the warning signs on the filter. Please ensure that the signs
are not removed nor their legibility impaired by external influences.
Death, serious bodily injury and substantial material damage to equipment may occur if the appro-
priate safety measures are not carried out or the warnings in the text are not observed.
Using according to the terms
The EMC filters may be used only for their intended application within the specified values in low-
voltage networks in compliance with the instructions given in the data sheets and the data book.
The conditions at the place of application must comply with all specifications for the filter used.
Warnings
■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such
as planning, assembly, installation, operation, repair and maintenance. They must be provided
with the corresponding documentation.
■ Danger of electric shock. EMC filters contain components that store an electric charge. Danger-
ous voltages can continue to exist at the filter terminals for longer than five minutes even after
the power has been switched off.
■ The protective earth connections shall be the first to be made when the EMC filter is installed and
the last to be disconnected. Depending on the magnitude of the leakage currents, the particular
specifications for making the protective-earth connection must be observed.
■ Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen-
cies that may cause resonances etc. can lead to destruction of the filter housing.
■ EMC filters must be protected in the application against impermissible exceeding of the rated
currents by suitable overcurrent protective.
9
01/06
EMC filters
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As
a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g.
installation of protective circuitry or redundancy) that no injury or damage is sustained by third
parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products.
Consequently, we cannot guarantee that all products named in this publication will always be
available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version
of the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
10 01/06
相关型号:
SI9130DB
5- and 3.3-V Step-Down Synchronous ConvertersWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135LG-T1-E3
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9135_11
SMBus Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9136_11
Multi-Output Power-Supply ControllerWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130CG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130LG-T1-E3
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9130_11
Pin-Programmable Dual Controller - Portable PCsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137DB
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9137LG
Multi-Output, Sequence Selectable Power-Supply Controller for Mobile ApplicationsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
SI9122E
500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification DriversWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY
©2020 ICPDF网 联系我们和版权申明