Filters for Power Lines  
16 to 100 A,  
100 dB from 150 kHz  
Series/Type:  
B84299*B001/B84299*E001  
Date: January 2004  
EPCOS AG 2004. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the  
information contained therein without EPCOS' prior express consent is prohibited.  
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical  
and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Associ-  
ation), unless otherwise agreed.  
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
2- and 4-line-filters  
Standard filters for measuring cabins  
Single-stage  
Stopband attenuation 150 kHz to 40 GHz  
Features  
General-purpose use through design with separate lines without intercoupling  
Use of single chokes. Thus the insertion loss values are not reduced under all operating cur-  
rent conditions and not when operated with artificial mains networks (AMN) or other equipment  
with high leakage currents.  
Insertion loss to CISPR 17  
Design  
The electrical components are incorporated in an RF-tight case of stainless steel. The cables  
enter through glands. The RF-tight termination of the openings is produced by specially shaped  
lids.  
The conductors and equipment grounding conductor are connected by threaded bolts. The sur-  
face around the fixing holes is left as bare metal (unpainted) to ensure good RF contact with met-  
al surfaces (chassis, ground).  
Protective measures (grounding)  
The high capacitances between the lines and ground require special protective measures. If there  
are no product-specific requirements, protection with a secondary ground wire (cross section min.  
10 mm2) in accordance with EN 50178 is necessary. For this purpose the filter case have con-  
necting bolts at each end.  
Resistors are incorporated in the filter to discharge capacitors after turn-off.  
Scope of supply  
Filters are supplied complete with all parts required for RF-tight installation (fixing screws,  
flanges, RF gaskets, cable glands) and installation instructions.  
Installation  
No welding is needed on the shielding wall, so any subsequent installation is quite simple.  
Accessories and special versions  
RF-tight flexible connector fittings are available for installation spaced away from the shielding  
wall. Filters with an EMP protection add-on for surge currents up to 100 kA per line are available  
on request. To match requirements, filters can be supplied with different kinds of EMC or shield-  
ing cable glands.  
Tests  
All filters are 100% tested and the results are archived under a filter's serial number. If required, a  
test report can be generated for the serial number.  
2
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Circuit diagrams  
2-line filters  
16 and 32 A  
63 and 100 A  
4-line filters  
16 and 32 A  
63 and 100 A  
3
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Insertion loss αe (typical values at Z = 50 )  
Asymmetrical measurement circuit  
to MIL-STD-220A  
General technical data  
Rated voltage  
2-line filters  
VR  
VR  
250  
V
Line/line  
Line/case  
Line/line  
Line/case  
Rated voltage  
4-line filters  
440  
V
250  
V
Rated frequency  
Rated current  
fR  
IR  
50/60  
Hz  
See characteristics  
Referred to +40 °C ambient  
temperature  
Maximum admissible  
overcurrent  
Iover  
75 IR for 50 ms  
10 IR for 1 s  
2 IR for 1 min  
1.4 IR for 15 min  
Test voltage  
Vtest 1200 VDC, 2 s  
1200 VDC, 2 s  
Line/line  
Line/case  
Voltage drop/phase  
V  
<1  
%
Of VR at 50 Hz and IR  
Per line  
Maximum DC resistance  
Rmax See characteristics  
4
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
General technical data (continued)  
Power dissipation  
PD  
See characteristics  
At rated current IR  
Capacitive reactive current/line Ireactive See characteristics  
At 400/230 V and 50 Hz (typical  
value)  
Max. permissible harmonic  
distortion (THD)  
8
%
To EN 50160  
Permissible ambient  
temperature  
TA  
25/+40  
°C  
Climatic category  
(EN 60068-1)  
25/085/56  
25 °C/+85 °C/56 days damp  
heat test  
Mechanical version  
C
D
Cable glands at both ends or  
flexible connector fitting  
Direct connection to shielding  
wall  
Characteristics and ordering codes  
IR  
Mechanical Rmax  
version  
PD  
W
Ireactive Dimensional Page Approx. Ordering code  
drawing  
weight  
kg  
A
mΩ  
A
2-line filters  
C
D
C
D
C
D
C
D
0.7  
0.7  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
6
7
8
9
10  
11  
12  
13  
B84299C2160B001  
B84299D2160B001  
B84299C2320B001  
B84299D2320B001  
B84299C1630B001  
B84299D1630B001  
B84299C1101B001  
B84299D1101B001  
16  
16  
32  
32  
63  
63  
100  
100  
< 25  
< 25  
< 20  
< 20  
< 3.0  
< 3.0  
< 1.5  
< 1.5  
< 15  
< 15  
< 40  
< 40  
< 25  
< 25  
< 30  
< 30  
1
2
3
4
5
6
7
8
8
8
15  
15  
18  
18  
18  
18  
4-line filters  
C
D
C
D
C
D
C
D
0.7  
0.7  
1.0  
1.0  
1.0  
1.0  
1.0  
1.0  
14  
15  
16  
17  
10  
11  
12  
13  
B84299C2160E001  
B84299D2160E001  
B84299C2320E001  
B84299D2320E001  
B84299C1630E001  
B84299D1630E001  
B84299C1101E001  
B84299D1101E001  
16  
16  
32  
32  
63  
63  
100  
100  
< 50  
< 50  
< 20  
< 20  
< 3.0  
< 3.0  
< 1.5  
< 1.5  
< 30  
< 30  
< 40  
< 40  
< 35  
< 35  
< 45  
< 45  
9
10  
11  
12  
5
6
7
8
16  
16  
20  
20  
20  
20  
20  
20  
5
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawings  
Dimensional drawing 1 (cable glands at both ends)  
2 x 16 A  
B84299C2160B001  
Input end:  
Cable gland PG 21 (mounted)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall with connector fitting, see page 18.  
6
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 2 (direct connection to shielding wall)  
2 x 16 A  
B84299D2160B001  
Input end:  
Cable gland PG 21 (mounted)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall, see page 18.  
7
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 3 (cable glands at both ends)  
2 x 32 A  
B84299C2320B001  
Input end:  
Cable gland PG 21 (mounted)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall with connector fitting, see page 18.  
8
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 4 (direct connection to shielding wall)  
2 x 32 A  
B84299D2320B001  
Input end:  
Cable gland PG 21 (mounted)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall, see page 18.  
9
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 5 (cable glands at both ends)  
2 x 63 A / 4 x 63 A  
B84299C1630B001, ...E001  
Input end:  
Cable gland PG 29/21  
(PG 29 mounted, PG 21 and reducer ring in accessory bag)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall with connector fitting, see page 18.  
10  
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 6 (direct connection to shielding wall)  
2 x 63 A / 4 x 63 A  
B84299D1630B001, ...E001  
Input end:  
Cable gland PG 29/21  
(PG 29 mounted, PG 21 and reducer ring in accessory bag)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall, see page 18.  
11  
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 7 (cable glands at both ends)  
2 x 100 A / 4 x 100 A  
B84299C1101B001, ...E001  
Input end:  
Cable gland PG 42/29  
(PG 42 mounted, PG 29 and reducer ring in accessory bag)  
Cable gland PG 42/29  
Shielded end:  
(cable gland PG 42, PG 29 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 42  
PG 29  
29 to 31 mm  
17 to 19 mm  
32 to 34 mm  
20 to 22 mm  
35 to 37 mm  
23 to 25 mm  
38 to 40 mm  
26 to 28 mm  
RF-tight connection to shielding wall with connector fitting, see page 18.  
12  
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 8 (direct connection to shielding wall)  
2 x 100 A / 4 x 100 A  
B84299D1101B001, ...E001  
Input end:  
Cable gland PG 42/29  
(PG 42 mounted, PG 29 and reducer ring in accessory bag)  
Cable gland PG 42/29  
Shielded end:  
(cable gland PG 42, PG 29 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 42  
PG 29  
29 to 31 mm  
17 to 19 mm  
32 to 34 mm  
20 to 22 mm  
35 to 37 mm  
23 to 25 mm  
38 to 40 mm  
26 to 28 mm  
RF-tight connection to shielding wall, see page 18.  
13  
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 9 (cable glands at both ends)  
4 x 16 A  
B84299C2160E001  
Input end:  
Cable gland PG 21 (mounted)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall with connector fitting, see page 18.  
14  
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 10 (direct connection to shielding wall)  
4 x 16 A  
B84299D2160E001  
Input end:  
Cable gland PG 21 (mounted)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall, see page 18.  
15  
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 11 (cable glands at both ends)  
4 x 32 A  
B84299C2320E001  
Input end:  
Cable gland PG 21 (mounted)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall with connector fitting, see page 18.  
16  
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
Dimensional drawing 12 (direct connection to shielding wall)  
4 x 32 A  
B84299D2320E001  
Input end:  
Cable gland PG 21 (mounted)  
Cable gland PG 29/21  
Shielded end:  
(cable gland PG 29, PG 21 and reducer ring in accessory bag)  
Paint color: RAL 7035 (light gray, semigloss)  
Fixing dimensions  
The cable glands (with cutout sealing ring) are suitable for the following overall cable diameter:  
PG 29  
PG 21  
17 to 19 mm  
9 to 11 mm  
20 to 22 mm  
12 to 14 mm  
23 to 25 mm  
15 to 17 mm  
26 to 28 mm  
18 to 20 mm  
RF-tight connection to shielding wall, see page 18.  
17  
Filters for power lines  
B84299*B001  
B84299*E001  
16 to 100 A, 100 dB from 150 kHz  
RF-tight connection to shielding wall with connector fitting (mechanical version C)  
Cable  
gland  
Connector fitting (must Ordering code  
be ordered separately)  
Hole in shielding Bare metal area  
wall  
37 +0.5 mm  
54 +0.5 mm  
on shielding wall  
55 +5 mm  
PG 29  
PG 42  
Nominal width 25 mm  
Nominal width 40 mm  
B84298A0042L***  
B84298A0044L***  
70 +5 mm  
(***: add required length in cm (see also chapter "Installation accessories").  
RF-tight connection to shielding wall (mechanical version D)  
Cable  
gland  
Parts for RF-tight mounting (in accessory bag) Required hole in Bare metal area  
shielding wall  
on shielding wall  
PG 21  
PG 29  
PG 42  
Suitable cable gland with  
long thread, RF gasket  
and check nut.  
37 +0.5 mm  
55 +5 mm  
54 +0.5 mm  
70 +5 mm  
18  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY