1626-2-20A [ETAL]

Protection of electrical systems of passenger cars, trucks, buses, watercraft, extra low voltage wiring systems;
1626-2-20A
型号: 1626-2-20A
厂家: ETAL Group    ETAL Group
描述:

Protection of electrical systems of passenger cars, trucks, buses, watercraft, extra low voltage wiring systems

电路保护
文件: 总2页 (文件大小:231K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Thermal automotive Mini-CBE 1626-...  
Description  
Single pole, thermal miniaturised circuit breaker designed for automotive  
applications. Fits into fuse blocks designed to ISO 8820-3, Type F.  
Automatic reset (for DC 12 V only) and open circuit (modified reset to  
SAE) version optional. Open circuit version ensures contacts staying  
open as long as power is on. The circuit breaker will reset after the  
load is removed. Particularly suitable for installation in inaccessible  
locations.  
Current ratings correspond to those of blade fuses. Clear colour  
coding of the ratings: blade fuse and circuit breaker of the same colour  
have the same rating.  
1
Breakers rated 7.5 A through 30 A have a fast characteristic curve and  
only hold 70 % of their rated current continuously.  
1626-1/-2  
1626-3  
1626-3H  
US patent number: US 8,576,042,B2  
Technical data  
Voltage rating  
1626-1/-2: DC 12 V  
1626-3/-3H: DC 12 V, DC 24 V  
1626-1/-2: DC 14.5 V  
1626-3/-3H: DC 29.0 V  
5...30 A  
Typical applications  
Max. voltage rating  
Current ratings  
Protection of electrical systems of passenger cars, trucks, buses,  
watercraft, extra low voltage wiring systems.  
5 A: medium characteristic curve  
7.5...30 A: fast characteristic curve  
Service short-circuit  
breaking capacity  
Ordering information  
300 operations at 2 x IN  
Ambient temperature  
-40...+85 °C (-40…+185 °F)  
Type No.  
(for higher temperatures please enquire)  
1626 single pole thermal Mini-CBE with standard characteristic curve  
Version, according to SAE J553  
Reset period for 1626-1  
(at 23 °C)  
1
2
3
type 1, DC 12 V automatic reset  
type 2, DC 12 V modified reset  
type 3, DC 24 V with reset button  
≤ 15 s  
< 35 s  
Reset period for 1626-2  
(at 23 °C) after 5 sec at  
rated voltage  
3H type 3*, DC 24 V with reset button and manual release facility  
Current ratings  
Degree of protection  
(IEC 60529)  
5
7.5  
10  
15  
20  
25 30 A  
operating area IP40 (-3)  
operating area IP50 (-1, -2)  
terminal area IP00  
1626 - 1 - 10 A ordering example  
Ultimate short-circuit  
breaking capacity  
≥ 3 break operations at 150 A, or  
≥ 1 break operation at 2,000 A  
Current ratings, typical voltage drop values and colour coding  
Vibration  
10 g (57-500 Hz), 0.38 mm (10-57 Hz)  
to IEC 60068-2-6, test Fc  
Current rating (A)  
Voltage drop (mV) Housing cap colour  
10 frequency cycles/axis  
SAE-J553, Step No. 14, § 4.2.7.1.5  
5
< 150  
< 150  
< 150  
< 150  
< 150  
< 150  
< 150  
light brown  
brown  
red  
7.5  
10  
15  
20  
25  
30  
Shock  
50 g (11 ms)  
to IEC 60068-2-27, test Ea  
SAE-J553, Step No. 14, § 4.2.7.1.6  
blue  
Corrosion  
Humidity  
96 hrs in 5 % salt mist,  
to IEC 60068-2-11, test Ka  
SAE-J553, Step No. 14, § 4.2.7.1.3  
yellow  
white  
240 hrs in 95 % RH,  
to IEC 60068-2-78, test Cab  
SAE-J553, Step No. 14, § 4.2.7.1.2  
light green  
Mass  
approx. 3 g  
Caution:  
It is good practice to switch off the vehicle’s ignition system before  
manually releasing or re-setting the circuit breaker. Free travel of the  
reset button must be ensured! Please ensure to push in the actuator  
smoothly and completely.  
All dimensions without tolerances are for reference only. In the interest of improved design,  
performance and cost effectiveness the right to make changes in these specifications without  
notice is reserved. Product markings may not be exactly as the ordering codes. Errors and  
omissions excepted.  
1646  
www.e-t-a.de  
1
Thermal automotive Mini-CBE 1626-...  
Dimensions  
Internal connection diagrams  
1ꢀꢁꢀꢂꢃ  
1ꢀꢁꢀꢂ1  
1ꢀꢁꢀꢂꢁ  
1ꢀꢁꢀꢂꢃꢄ  
1ꢀꢁꢀꢂ1 ꢃ 1ꢀꢁꢀꢂꢁ  
ꢁꢀꢅ6  
1
1ꢄꢁꢄ  
ꢁꢇꢀ4  
1
1
1
GERMANY  
1
Typical time/current characteristic curve at +23 °C / +73.4 °F  
ꢂ ꢅ  
1ꢍꢍꢍꢍ  
4ꢁꢇ  
ꢃꢁꢂ  
ꢁꢃꢄꢀ  
ꢁ1ꢅꢅ  
ꢀꢁꢂ  
ꢁ11ꢃ  
ꢀꢁꢂ  
1ꢍꢍꢍ  
ꢄꢁꢂ  
ꢁ14ꢆ  
1ꢃꢁꢆ  
ꢁ4ꢀꢆ  
1ꢀꢁꢅ  
ꢁꢇꢃꢃ  
1ꢍꢍ  
1ꢍ  
1ꢀꢁꢀꢂꢃ  
1ꢄꢁꢄ  
ꢁꢇꢀ4  
ꢄꢁꢇ  
ꢁ1ꢄꢂ  
ꢃꢁ6  
ꢁꢃꢀ4  
ꢁꢃꢅꢆ  
1ꢁꢂ  
ꢁꢃꢅ1  
1
ꢍꢎ1  
ꢍꢎ4 ꢍꢎ6 ꢍꢎ1  
4
6
1ꢍ  
ꢐꢍ  
4ꢍ  
GERMANY  
ꢀꢂꢄꢅꢇ ꢁꢋꢀꢅꢊ ꢈꢌꢁꢁꢅꢆꢀ  
ꢀꢁꢂꢁꢁꢁꢃꢄ ꢅ  
1ꢍꢍꢍꢍ  
1ꢍꢍꢍ  
1ꢀꢁꢀꢂꢃꢄ  
1ꢍꢍ  
1ꢍ  
1ꢄꢁꢄ  
ꢁꢇꢀ4  
ꢁꢀꢅꢇ  
4ꢁꢂ  
ꢄꢁꢇ  
ꢁ1ꢄꢂ  
ꢁ1ꢂꢆ  
1
ꢍꢎ1  
ꢍꢎ4 ꢍꢎ6 ꢍꢎꢏ 1  
4
6 ꢏ 1ꢍ  
4ꢍ  
ꢀꢂꢄꢅꢇ ꢁꢋꢀꢅꢊ ꢈꢌꢁꢁꢅꢆꢀ  
GERMANY  
The time/current characteristic curve depends on the ambient temperature  
prevailing. In order to eliminate nuisance tripping, please multiply the  
circuit breaker current ratings by the derating factor shown below. See also  
section Technical information.  
Ambient temperature °F  
Ambient temperature °C  
-40  
-40  
-22  
-30  
-4  
-20  
+14  
-10  
+32  
0
+50  
+10  
Derating factor  
0.73  
0.78  
0.82  
0.86  
0.91  
0.95  
Ambient temperature °F  
Ambient temperature °C  
+73.4 +104 +122 +140 +158 +185  
+23  
+40  
+50  
+60  
+70  
+85  
mm  
inch)  
This ist a metric design and millimeter dimensions take precedence (  
Derating factor  
1
1.09  
1.16  
1.25  
1.33  
1.43  
2
www.e-t-a.de  
1646  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY