1658-A00-00-P10-6A [ETAL]
Battery chargers, consumer products, power supplies, motors;型号: | 1658-A00-00-P10-6A |
厂家: | ETAL Group |
描述: | Battery chargers, consumer products, power supplies, motors 电池 |
文件: | 总4页 (文件大小:267K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Thermal Overcurrent Circuit Breaker 1658-...
Description
Very cost effective design to meet international requirements. No
exposed metal parts which are, or could become, current-carrying
except for terminals. R-type TO CBE to EN 60934.
l
l
l
Manual reset, cycling trip free mechanism
Extremely small and lightweight
UL, CSA, VDE and EN 60934 (IEC 60934) approved
Typical applications
Battery chargers, consumer products, power supplies, motors.
1
1658-...
Ordering information
Type No.
Technical data
1658 single pole thermal circuit breaker
Threadneck design
G21 manual reset type, 3/8“-27 threadneck
A00 auto reset type, without threadneck
Hardware
For further details please see chapter: Technical Information
Voltage rating
Current ratings
AC 240 V; DC 28 V
5...30 A
00 no hardware
01 one PAL nut Y306 671 01, bulk
02 one PAL nut Y306 671 01,
one knurled nut Y307 117 02, bulk
Terminals
Typical life
AC + DC
5...16 A
1,000 operations at 2 x IN, inductive
17...25 A 1,000 operations at 2 x IN, resistive
P10 blade terminals A6.3-0.8 (QC .250)
P13 blade terminals A6.3-0.8 (QC .250), 90°
Current ratings
operat.
IN
UN
Behaviour at rated
switching capacity
(EN 60934;
40
40
40
5...16 A
5...16 A
AC 240 V 6 x IN ind
5 ...30 A
test sequence D)
DC 28 V
4 x IN ind
1658 - G21 - 02 - P10 - 5 A
Ordering example
17...25 A AC 240 V 120 A
resistive
120 A
resistive
* Screws and lock washers bulk shipped
40
17...25 A DC 28 V
Packaging unit: minimum order quantity 250 pieces
Ambient temperature
-20...+60 °C (-4...+140 °F),
≤ 7 A max. +40 °C (+104 °F)
Preferred types
Insulation co-ordination rated impulse
(IEC 60664 and 60664 A) withstand voltage
2.5 kV
pollution
degree
Preferred types Standard current ratings (A)
2
reinforced insulation in operating area
5
6
7
8
9
10 12 15 16 20 25 30
Dielectric strength
x
x
x
x
x
x
x
x
x
x
x
x
1658-G21-02-P10-
(IEC 60664 and 60664A) test voltage
operating area
AC 3,000 V
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
1658-G21-02-P13-
1658-A00-00-P10-
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity Icn 5...7 A
8...30 A
180 A
200 A
Interrupting capacity
(UL 1077/EN 60934 PC1) 5...16 A
IN
UN
Standard current ratings and typical voltage drop values
AC 240 V 2,000 A
5...30 A
5...30 A
5...30 A
AC 120 V 2,000 A
DC 32 V 2,500 A
DC 28 V 2,000 A (1658-A..)
Current
rating (A)
voltage drop
values (mV)
Current
rating (A)
voltage drop
values (mV)
Degree of protection
(IEC 60529/DIN 40050)
operating area IP40
terminal area IP00
5
≤ 250
≤ 250
≤ 250
≤ 250
≤ 250
≤ 250
12
15
16
20
25
30
≤ 250
≤ 250
≤ 250
≤ 250
≤ 250
≤ 250
6
Vibration
8 g (57-500 Hz) 0.61 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
7
8
Shock
30 g (11 ms)
to IEC 60068-2-27, test Ea
9
Corrosion
Humidity
Mass
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
10
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 16 g
1635
www.e-t-a.de
1
Thermal Overcurrent Circuit Breaker 1658-...
Dimensions
Internal connection diagram
ø6
1
.236
ꢀ
1
2
17.5
.689
Typical time/current characteristics
1
15.7
.618
1ꢃꢃꢃꢃ
1ꢃꢃꢃ
ꢔ6ꢃ ꢕꢖ
ꢔ1ꢁꢃ ꢕꢗ
32
1.26
ꢔꢀ3 ꢕꢖ
ꢔꢘ3ꢓꢁ ꢕꢗ
ꢙꢀꢃ ꢕꢖ
ꢙꢁ ꢕꢗ
A00
1ꢃꢃ
1ꢃ
1
tightening torque max. 0.8 Nm
3/8-27UNS-2A
G21
See ordering information for mounting hardware.
ꢃꢓ1
1
ꢀ
ꢁ
6
ꢂ 1ꢃ
ꢀꢃ
ꢁꢃ
Terminal design
ꢄ ꢅꢆꢇꢈꢉ ꢊꢋꢅꢈꢌ ꢍꢎꢊꢊꢈꢏꢅ
P13
P10
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the circuit
breaker current ratings by the derating factor shown below. See also section
Technical information.
1
2
1
2
8.5
.335
blade terminals DIN 46244-A6.3-0.8 (QC .250)
angled 90°
Ambient temp. °F
Ambient temp. °C
-4
-20
+14
-10
+32 +73.4 +104 +122 +140
blade terminals DIN 46244-A6.3-0.8
(QC .250)
0
+23
+40
+50 +60
Derating factor IN > 7A 0.83 0.85
0.9
1
1
1.1
1.23
1.18 1.25
IN < 7A 0.74 0.76 0.82
-
-
Installation drawing
ꢂꢋꢊꢉꢈꢅꢆꢄꢇ ꢈꢉꢊꢈ
1
ꢀ
ꢌ
5
5
ꢌ
ꢎ1ꢏꢍ
ꢎ1ꢏꢍ
ꢎ15ꢍ
ꢎ15ꢍ
ꢁꢂꢃꢄꢅꢆꢄꢇ ꢈꢉꢊꢈ
mm
inch
This is a metric design and millimeter dimensions take precedence (
)
2
www.e-t-a.de
1635
Thermal Overcurrent Circuit Breaker 1658-...
Accessories
Reset button seal for 3/8", 27-thread,
PAL nut 3/8", 27-thread
Y 306 671 01
short
long
X 201 285 01 (IP64)
X 200 799 01 (IP64)
1ꢃꢂ3
ꢇꢂ5
ꢋ563
ꢋꢎꢍꢏ
ꢁꢂ5
ꢋꢎꢊꢎ
3/8-27 UNS-2B
3/8-27 UNS-2B
3ꢄꢅꢆꢇꢈꢉꢊꢋꢆꢇꢌ
1
Knurled nut 3/8", 27-thread
plastic (standard)
Y 307 117 02
Panel cut out
1658-3/8-27 UNS-2A
ꢀ15
3
ꢋ5ꢍ1
ꢋ11ꢏ
Ø 9,6
3ꢄꢅꢆꢇꢈꢉꢊꢋꢆꢇꢌ
Knurled nut 3/8", 27-thread
nickel-plated brass
Y 300 190 03
Approvals
ꢉ13
ꢊꢋ5
Authority Standard
Rated voltage Current ratings
1658-G
AC 240 V
ꢋ51ꢊ
ꢋꢎꢍꢏ
VDE
UL
IEC/EN 60934
5 A…25 A
5 A…25 A
DC 28 V
3ꢐꢏꢃꢊꢑꢒꢓꢁꢃꢊꢆ
UL 1077
AC 250 V
AC 240 V
AC 125 V
DC 32 V
5 A…15 A
5 A…16 A
5 A…30 A
5 A…30 A
CSA C22.2 No 235
UL 1500
Ignition Protected
Hex nut 3/8", 27-thread
nickel-plated brass
Y 300 192 01
CSA
CSA C22.2 No 235 AC 250 V
AC 240 V
5 A…15 A
5 A…16 A
5 A…30 A
5 A…30 A
AC 125 V
DC 32 V
3ꢐꢏꢃꢊꢑꢒꢓꢁꢃꢊꢆ
ꢊꢋ5
ꢋꢎꢍꢏ
1658-A
VDE
UL
IEC/EN 60934
UL 1077
AC 240 V
DC 28 V
5 A…25 A
5 A…25 A
AC 125 V
DC 28 V
5 A…30 A
5 A…30 A
ꢁꢔ1ꢌ
ꢋ551
Press to Reset Plate for 3/8"
thread, aluminium
Y 301 059 02
ꢉꢊ1ꢋꢌ
ꢋꢏꢌ3
ꢁꢂꢃ
ꢋꢎ16
ꢇ
ꢅ
ꢄ
ꢆ
ꢀ
ꢃ
ꢀ
ꢇ
ꢃ
ꢀ
ꢍ
ꢂ
ꢎꢏ
ꢁ
ꢋ
ꢀ
ꢋ
ꢎ
ꢐ
ꢑ
ꢉꢍꢋꢍ
ꢋ3ꢍꢎ
mm
)
This is a metric design and millimeter dimensions take precedence (
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
1635
www.e-t-a.de
3
1
4
www.e-t-a.de
1635
相关型号:
©2020 ICPDF网 联系我们和版权申明