12S5.1500FW [ETC]
DC to DC Converter ; 直流到直流转换器\n型号: | 12S5.1500FW |
厂家: | ETC |
描述: | DC to DC Converter
|
文件: | 总7页 (文件大小:121K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
5 to 7.5 Watt FW Single Series DC/DC Converters
Description
Features
!
The low voltage FW single output converters are designed for
ultra wide input range, low noise industrial and instrument
applications requiring low input operating voltages. The wide
input range (3:1) is ideal for battery or unregulated input
applications.
Low noise outputs, 70 mV P-P maximum
!
Very low reflected ripple, 50 mA P-P maximum
!
Excellent regulation from no load to full load 0.2%
maximum
These converters are state-of-the-art 100 kHz designs that
provide outstanding line and load regulation with efficiencies
approaching 82%.
!
Excellent line regulation, 0.1% maximum
!
Efficiencies to 82%
!
The single outputs are regulated with a high loop gain
current mode control method that provides linear regulator
typeperformancewithatrue, highefficiencyswitchingDC/DC
topology. The large amount of loop gain also insures excellent
input ripple rejection and line transient response.
Six-sided shielded low thermal gradient copper case
!
Five Year Warranty
Selection Chart
All converters in this series are protected from output short
circuit, thermal overload and overvoltage transients on the
input and output.
Input Range
Output
VDC
Output
mA
VDC
Model
MIN
9
MAX
27
12S5.1500FW
12S12.625FW
12S15.500FW
5
1500
625
9
27
12
15
9
27
500
7.5 Watt FW Single Series Block Diagram
ISOLATION TRANSFORMER
+ OUTPUT
CMN
3
5
A
THERMAL SHUTDOWN
+ INPUT 1
CURRENT
MODE
PWM
- INPUT
2
BANDGAP REFERENCE
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
1
5 to 7.5 Watt FW Single Series DC/DC Converters
Input Parameters*
Model
12S5.1500FW
12S12.625FW
12S15.500FW
Units
MIN
MAX
TYP
MAX
TYP
TYP
9.0
27.0
23
50
775
14
Voltage Range
VDC
25
50
815
12
22
50
765
16
Reflected Ripple (2)
mA P-P
mA
Input Current Full Load
No Load
Efficiency
TYP
TYP
77
81
82
%
Switching Frequency
100
kHz
Maximum Input Overvoltage
100ms No Damage
MAX
TYP
48
VDC
Turn-on Time, 1% Output Error
Recommended Fuse
10
(3)
ms
AMPS
Output Parameters*
Model
12S5.1500FW
12S12.625FW
12S15.500FW
Units
Output Voltage
5
12
15
VDC
MIN
MAX
0.0
1500
0.0
625
0.0
500
Rated Current
mA
MIN
TYP
MAX
4.950
5.000
5.050
11.900
12.000
12.100
14.900
15.000
15.100
Voltage Range
VDC
TYP
MAX
TYP
MAX
0.08
0.2
0.02
0.1
0.02
0.1
0.01
0.1
0.02
0.1
0.01
0.1
Load Regulation 0-100% Full Load
%
%
Line Regulation
Vin = Min-Max VDC
Short Term Stability (5)
Long Term Stability
TYP
TYP
TYP
TYP
TYP
0.05
0.02
<0.2
300
270
25
0.02
%/24Hrs
%/kHrs
µs
Transient Response (6)
Dynamic Response (7)
Input Ripple Rejection (8)
200
200
37
200
210
25
mV peak
dB
TYP
MAX
35
70
Noise, 0-20MHz bw (2)
mV P-P
TYP
MAX
50
150
Temperature Coefficient
ppm/°C
Overvoltage Clamp (9)
TYP
6.8
15
18
VDC
Short Circuit Protection to
Common for all Outputs
Provides minimum of 8 hours continous protection with current limiting and thermal
overload techniques
A
NOTES:
All Parameters measured at Tc=25°C, nominal input voltage
and full rated load unless otherwise noted. Refer to the
CALEX Application Notes for the definition of terms,
measurement circuits and other information.
(7) Dynamic response is the peak overshoot during a transient as
defined in note 6.
*
(8) The input ripple rejection is specified for DC to 120 Hz ripple with
a modulation amplitude of 1% of Vin.
(2) Noise is measured per CALEX Application Notes. Measurement
bandwidth is 0-20 MHz.
(9) For module protection only, see note 3.
(10) Thefunctionaltemperaturerangeisintendedtogiveanadditional
data point for use in evaluating this power supply. At the low
functional temperature the power supply will function with no
side effects, however, sustained operation at the high functional
temperature will reduce expected operational life. The data
sheet specifications are not guaranteed over the functional
temperature range.
(3) DeterminethecorrectfusesizebyreferringtoCALEXApplication
Notes.
(4) Case is tied to Pin 5, - Output.
(5) Short term stability is specified after a 30 minute warmup at full
load, constant line and recording the drift over a 24 hour period.
(6) The transient response is specified as the time required to settle
from a 50 to 75 % step load change (rise time of step = 2 µSec)
to a 1% error band.
(11) Thecasethermalimpedanceisspecifiedasthecasetemperature
rise over ambient per package watt dissipated.
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
2
5 to 7.5 Watt FW Single Series DC/DC Converters
General Specifications*
All Models
Units
Isolation (4)
Breakdown Voltage
Input-Output
10µA Leakage
Input to Output
Capacitance
MIN
TYP
700
340
VDC
pF
Environmental
Case Operating Range
No Derating
MIN
MAX
MIN
-25
85
-40
95
°C
°C
Case Functional Range (10)
MAX
MIN
MAX
TYP
-55
105
10
Storage Range
°C
°C/Watt
°C
Thermal Impedance (11)
Thermal Shutdown
Case Temperature
TYP
100
General
Unit Weight
Mounting Kits
TYP
1.7
oz
MS15 & MS6
Typical Performance (Tc=25°C, Vin=Nom VDC, Rated Load).
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.010 inches
OUTPUT VOLTAGE Vs. OUTPUT LOAD
X.XXX dimensions: ±0.005 inches
120
Seal around terminals is not hermetic. Do not immerse units in any
liquid.
100
80
60
40
20
0
Pin
1
2
Function
+INPUT
-INPUT
3
5
+OUTPUT
CMN
0
20
40
60
80
100
120
140
160
OUTPUT LOAD (%)
48S5.1500, 48S12.625 & 48S15.500
EFFICIENCY Vs. LOAD (12V OUTPUT)
EFFICIENCY Vs. LINE INPUT (12V OUTPUT)
INPUT CURRENT Vs LINE INPUT VOLTAGE
90
80
70
60
85
80
75
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0.00
50% FULL LOAD
LINE = 12VDC
100%
FULL LOAD
LINE = 9VDC
A
100% FULL LOAD
50%
FULL LOAD
LINE = 27VDC
0
10
20
30
40
50
60
70
80
90
100
9
11
13
15
17
19
21
23
25
27
0
10
20
30
40
50
60
70
80
LOAD (%)
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
OUTPUT VOLTAGE Vs CASE TEMPERATURE
OUTPUT IMPEDANCE Vs. FREQUENCY
DERATING
0.10
0.05
10
120
100
80
60
40
20
0
15 VOLT OUTPUT
↓ INFINITE
HEAT
SINK
NO HEAT
SINK
-0.00
-0.05
-0.10
-0.15
-0.20
-0.25
-0.30
1
↑
SAFE
← OPERATING →
AREA
.1
5 VOLT OUTPUT
↓
.01
-40
-20
0
20
40
60
80
100
10
100
1000
10000
100000
1000000
-40
-20
0
20
40
60
80
100
CASE TEMPERATURE (Deg C)
FREQUENCY (Hz)
AMBIENT TEMPERATURE (Deg C)
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
3
5 to 7.5 Watt FW Single Series DC/DC Converters
Description
Features
Improved Second Source Benefits:
These single output converters are designed for low noise,
telecommunications, industrial and instrument applications.
Their wide input range (2:1) makes them ideal for battery or
unregulated input applications.
!
Low noise outputs, 50 mV p-p maximum
!
Very low reflected ripple, 15 mA p-p maximum
These converters are state-of-the-art 120 KHz MOSFET
baseddesignsthatprovideoutstandinglineandloadregulation
with efficiencies approaching 85%.
!
Excellent regulation, 0.3% maximum
!
Improved line regulation, 0.1% maximum
!
Efficiencies to 84%
Reverse voltage protected input
Five Year Warranty
The outputs are regulated by a high loop gain current mode
controlmethodthatprovideslinearregulatortypeperformance
with a true, high efficiency switching DC/DC topology. The
large amount of loop gain also insures excellent input ripple
rejection and line transient response.
!
!
The FW Single converters are protected from output shorts
to common by a high speed, pulse-by-pulse, digital, current
limit circuit.
Selection Chart
Input Range
Output
VDC
Output
mA
VDC
Model
MIN
20
MAX
60
Theinputandoutputareovervoltageprotectedwithtransient
suppressordiodes.ULrecognitionunderspecificationnumbers
1459 and 1012 is currently pending.
48S5.1000FW *
48S5.1500FW *
48S12.625FW *
48S15.500FW *
5
1000
1500
625
36
72
5
36
72
12
15
36
72
500
* These units are Recognized to UL 1459-2
5 - 7.5 Watt FW Single Series Block Diagram
SHIELDED
ISOLATION TRANSFORMER
3
5
+ OUTPUT
CMN
A
C2
D1
PROTECTION
DIODE
C1
+ INPUT
- INPUT
1
2
CURRENT
MODE
PWM
Output
5
C1
C2
D1
68µF
10µF
10µF
78µF
20µF
20µF
6.8V
SIX-SIDED SHIELDED
COPPER CASE
12
15V
18V
BANDGAP REFERENCE
15
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
4
5 to 7.5 Watt FW Single Series DC/DC Converters
Input Parameters*
Model
48S5.1000FW
48S5.1500FW (13) 48S12.625FW (13) 48S15.500FW (13)
Units
MIN
MAX
TYP
MAX
TYP
TYP
20.0
60.0
36.0
72.0
36.0
72.0
36.0
72.0
Voltage Range
VDC
4
15
Reflected Ripple (2), 0-20MHz bw
mA P-P
mA
Input Current Full Load
No Load
139
5
195
3
190
4
185
4
Efficiency
TYP
TYP
75
80
82
85
%
Switching Frequency
120
80
kHz
Maximum Input Overvoltage
100ms No Damage
MAX
TYP
VDC
ms
Turn-on Time, 1% Output Error
Recommended Fuse
Reverse Polarity
10
(3)
70
VDC
Output Parameters*
Model
48S5.1000FW
48S5.1500FW
48S12.625FW
48S15.500FW
Units
VDC
mA
Output Voltage
Rated Current(4)
5
5
12
15
MIN
MAX
0.0
1000
0.0
1500
0.0
625
0.0
500
MIN
TYP
MAX
4.950
5.000
5.050
4.950
5.000
5.050
11.900
12.000
12.100
14.900
15.000
15.100
Voltage Range
100% Load
VDC
TYP
MAX
TYP
MAX
0.1
0.3
0.05
0.1
Load Regulation 0-100%
%
%
Line Regulation
Vin = Min-Max VDC
0.01
0.1
0.05
0.05
0.02
0.02
Short Term Stability (5)
TYP
%/24Hrs
Long Term Stability
TYP
TYP
TYP
TYP
< 0.2
%/kHrs
µs
Transient Response (6)
Dynamic Response (7)
Input Ripple Rejection (8)
50
125
180
200
200
150
170
100
mV peak
dB
38
Noise, 0-20MHz bw (2)
with 0.1µF External Capacitor
TYP
MAX
TYP
MAX
TYP
MAX
10
50
40
100
50
mV P-P
with no External Capacitor
Temperature Coefficient
Overvoltage Clamp (9)
ppm/°C
150
TYP
6.8
6.8
15
18
VDC
Short Circuit Protection to
Common for all Outputs
Provides minimum of 8 hours continous protection withAcurrent limiting and thermal
overload techniques
NOTES:
All parameters measured at Tc=25 °C, nominal input
voltage and full rated load unless otherwise noted. Refer to
the CALEX Application Notes for the definition of terms,
measurement circuits and other information.
(7) Dynamic response is the peak overshoot during a transient
as defined in note 6 above.
*
(8) The input ripple rejection is specified for DC to 120 Hz ripple with
a modulation amplitude of 1% of Vin.
(2) Noise is measured per CALEX Application Notes. The output
noiseismeasuredwitha0.1µF,50V,ceramiccapacitorconnected
directly across the output pins. Measurement bandwidth is 0-20
MHz.
(9) For module protection only, see also note 3.
(10) Case is tied to Pin 5, CMN.
(11) Thefunctionaltemperaturerangeisintendedtogiveanadditional
data point for use in evaluating this power supply. At the
low functional temperature the power supply will function with no
side effects, however sustained operation at the high functional
temperature will reduce expected operational life. The data
sheet specifications are not guaranteed over the functional
temperature range.
(3) Determine the correct fuse size by calculating the maximum DC
current drain at low line input, maximum load and then adding 20
to 25% to get the desired fuse size. A slow blow type fuse
is recommended.
(4) No minimum load required.
(5) Short term stability is specified after a 30 minute warm-up at full
load, constant line and recording the drift over a 24 hour period.
(12) Thecasethermalimpedanceisspecifiedasthecasetemperature
rise over ambient per package watt dissipated.
(6) The transient response is specified as the time required to settle
from a 50 to 75 % step load change (rise time of step = 2µ Sec)
to a 1% error band.
(13) These products are UL Recognized for an input voltage range of
36 to 60 VDC.
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
5
5 to 7.5 Watt FW Single Series DC/DC Converters
General Specifications
All Models
Units
Isolation
Isolation Voltage
Input-Output
Input-Case
10µA Leakage
Input to Output
Capacitance
MIN
MIN
1544
1544
VDC
pF
TYP
45
Environmental
Case Operating Range
No Derating
MIN
MAX
MIN
MAX
MIN
-25
80
-40
90
-55
105
°C
°C
Case Functional Range (11)
Storage Range
°C
MAX
BOTTOM
SIDE VIEW
Thermal Impedance (10)
General
TYP
10
°C/Watt
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.020 inches
Unit Weight
TYP
1.7
oz
Mounting Kits
MS6 & MS15
X.XXX dimensions: ±0.005 inches
Seal around terminal is not hermatic. Do not immerse units in any
liquid.
Pin
1
2
Function
+INPUT
-INPUT
3
5
+OUTPUT
CMN
Typical Performance (Tc=25°C, Vin=48 VDC, Full Rated Load).
48S5.1000FW
48S5.1000FW EFFICIENCY Vs LOAD
48S5.1000FW EFFICIENCY Vs LINE INPUT
INPUT CURRENT Vs LINE INPUT VOLTAGE
85
80
75
70
65
60
55
50
82
80
78
76
74
72
70
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0.00
LINE =
20VDC
LINE =
48VDC
100%
FULL LOAD
100%
FULL LOAD
LINE =
60VDC
A
50%
FULL LOAD
50%
FULL LOAD
0
20
40
60
80
100
20
25
30
35
40
45
50
55
60
0
10
20
30
40
50
60
LOAD (%)
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
48S5.1500FW EFFICIENCY Vs LOAD
48S12.625FW EFFICIENCY Vs LOAD
48S15.500FW EFFICIENCY Vs LOAD
85
80
75
70
65
60
55
85
80
75
70
65
60
55
90
85
80
75
70
65
60
55
LINE =
36VDC
LINE =
36VDC
LINE =
36VDC
LINE =
72VDC
LINE =
72VDC
LINE =
48VDC
LINE =
48VDC
LINE =
72VDC
LINE =
48VDC
0
20
40
60
80
100
0
20
40
60
80
100
0
20
40
60
80
100
LOAD (%)
LOAD (%)
LOAD (%)
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
6
5 to 7.5 Watt FW Single Series DC/DC Converters
Typical Performance (Tc=25°C, Vin=48 VDC, Full Rated Load).
48S5.1500FW EFFICIENCY Vs LINE INPUT
48S12.625FW EFFICIENCY Vs LINE INPUT
48S15.500FW EFFICIENCY Vs LINE INPUT
83
82
81
80
79
84
83
82
81
80
79
85
84
83
82
81
80
79
50%
100%
FULL LOAD
100%
FULL LOAD
FULL LOAD
50%
FULL LOAD
100%
FULL LOAD
50%
FULL LOAD
35
40
45
50
55
60
65
70
75
35
40
45
50
55
60
65
70
75
35
40
45
50
55
60
65
70
75
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
48S5.1500, 48S12.625 & 48S15.500
INPUT CURRENT Vs LINE INPUT VOLTAGE
OUTPUT VOLTAGE Vs. OUTPUT LOAD
OUTPUT IMPEDANCE Vs. FREQUENCY
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0.00
120
100
80
60
40
20
0
10
1
12 & 15V OUTPUT
100%
FULL LOAD
.1
50%
.01
.001
FULL LOAD
5V OUTPUT
100
0
10
20
30
40
50
60
70
80
0
20
40
60
80
100
120
140
160
10
1K
10K
100K
1M
LINE INPUT (VOLTS)
OUTPUT LOAD (%)
FREQUENCY (Hz)
OUTPUT VOLTAGE Vs CASE TEMPERATURE
DERATING
0.10
0.05
120
100
80
60
40
20
0
↓ INFINITE
HEAT
SINK
NO HEAT
SINK
-0.00
-0.05
-0.10
-0.15
-0.20
-0.25
-0.30
↑
SAFE
← OPERATING →
AREA
↓
-40
-20
0
20
40
60
80
100
-40
-20
0
20
40
60
80
100
CASE TEMPERATURE (Deg C)
AMBIENT TEMPERATURE (Deg C)
A
Manufacturing Company, Inc. • Concord, California 94520 • Ph: 925/687-4411 or 800/542-3355 • Fax: 925/687-3333 • www.calex.com • Email: sales@calex.com
7
相关型号: