1325A0101000 [ETC]

22 AWG stranded (7x30) TC conductors, plenum, Flamarrest insulation;
1325A0101000
型号: 1325A0101000
厂家: ETC    ETC
描述:

22 AWG stranded (7x30) TC conductors, plenum, Flamarrest insulation

文件: 总3页 (文件大小:98K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Detailed Specifications & Technical Data  
METRIC MEASUREMENT VERSION  
1325A Multi-Conductor - Double-Pair Cable  
For more Information  
please call  
1-800-Belden1  
Description:  
22 AWG stranded (7x30) TC conductors, plenum, Flamarrest® insulation, twisted pairs, individually  
shielded w/Beldfoil® (100% coverage), 24 AWG stranded TC drain wire, Flamarrest® jacket.  
Usage (Overall)  
Suitable Applications:  
Sound and Audio Systems, Intercom and PA Systems, Security Systems,  
Power-Limited Control Systems  
Physical Characteristics (Overall)  
Conductor  
AWG:  
# Pairs AWG Stranding Conductor Material  
2
22  
7x30  
TC - Tinned Copper  
Insulation  
Insulation Material:  
Insulation Trade Name Insulation Material  
Flamarrest®  
F-R PVC - Flame Retardant Polyvinyl Chloride  
Inner Shield  
Inner Shield Material:  
Inner Shield Trade Name Type Inner Shield Material  
Coverage (%)  
Beldfoil® (Z-Fold®)  
Tape Aluminum Foil-Polyester Tape 100  
Inner Shield Drain Wire AWG:  
AWG  
24  
Outer Jacket  
Outer Jacket Material:  
Outer Jacket Trade Name Outer Jacket Material  
Flamarrest®  
LS PVC - Low Smoke Polyvinyl Chloride  
Overall Cabling  
Overall Nominal Diameter:  
4.013 mm  
Pair  
Pair Color Code Chart:  
Number Color  
1
2
Black & Red  
White & Green  
Pair Lay Length & Direction:  
Twists/ft. (twist/m)  
8
Mechanical Characteristics (Overall)  
Operating Temperature Range:  
Bulk Cable Weight:  
0°C To +75°C  
28.276 Kg/Km  
120.101 N  
Max. Recommended Pulling Tension:  
Page 1 of 3  
05-10-2011  
Detailed Specifications & Technical Data  
METRIC MEASUREMENT VERSION  
1325A Multi-Conductor - Double-Pair Cable  
Min. Bend Radius (Install)/Minor Axis:  
40.640 mm  
Applicable Specifications and Agency Compliance (Overall)  
Applicable Standards & Environmental Programs  
NEC/(UL) Specification:  
CMP  
CMP  
Yes  
CEC/C(UL) Specification:  
EU CE Mark:  
EU Directive 2000/53/EC (ELV):  
EU Directive 2002/95/EC (RoHS):  
EU RoHS Compliance Date (mm/dd/yyyy):  
EU Directive 2002/96/EC (WEEE):  
EU Directive 2003/11/EC (BFR):  
CA Prop 65 (CJ for Wire & Cable):  
MII Order #39 (China RoHS):  
Yes  
Yes  
05/30/2006  
Yes  
Yes  
Yes  
Yes  
Flame Test  
UL Flame Test:  
UL910 Steiner Tunnel  
FT6  
CSA Flame Test:  
Plenum/Non-Plenum  
Plenum (Y/N):  
Yes  
Non-Plenum Number:  
8723  
Electrical Characteristics (Overall)  
Nom. Capacitance Conductor to Conductor:  
Capacitance (pF/m)  
111.554  
Nom. Conductor DC Resistance:  
DCR @ 20°C (Ohm/km)  
48.2307  
Nom. Inner Shield DC Resistance:  
DCR @ 20°C (Ohm/km)  
49.215  
Max. Operating Voltage - UL:  
Voltage  
300 V RMS  
Max. Recommended Current:  
Current  
2.8 Amps per conductor @ 25°C  
Related Documents:  
No related documents are available for this product  
Put Ups and Colors:  
Item #  
Putup  
Ship Weight  
9.072 KG  
9.072 KG  
4.763 KG  
9.072 KG  
Color  
Notes  
Item Desc  
1325A D151000  
1325A 0091000  
1325A 009500  
1325A 0101000  
305 MT  
305 MT  
152 MT  
305 MT  
BLUE  
C
2 FS PR #22 FLRST FLRST  
2 FS PR #22 FLRST FLRST  
2 FS PR #22 FLRST FLRST  
2 FS PR #22 FLRST FLRST  
WHITE  
WHITE  
BLACK  
Notes:  
C = CRATE REEL PUT-UP.  
Page 2 of 3  
05-10-2011  
Detailed Specifications & Technical Data  
METRIC MEASUREMENT VERSION  
1325A Multi-Conductor - Double-Pair Cable  
Revision Number: 1  
Revision Date: 05-11-2010  
© 2011 Belden, Inc  
All Rights Reserved.  
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications  
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not  
ensure product availability.  
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,  
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or  
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,  
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.  
All sales of Belden products are subject to Belden's standard terms and conditions of sale.  
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the  
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and  
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,  
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide  
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not  
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for  
determining the applicability of legislation and regulations based on their individual usage of the product.  
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.  
Page 3 of 3  
05-10-2011  

相关型号:

1325A1

Peripheral IC
ETC

1325A2

Peripheral IC
ETC

1325AD151000

22 AWG stranded (7x30) TC conductors, plenum, Flamarrest insulation
ETC

1325B0

Peripheral IC
ETC

1325B1

Peripheral IC
ETC

1325B2

Peripheral IC
ETC

1325G0

Peripheral IC
ETC

1325G1

Peripheral IC
ETC

1325G2

Peripheral IC
ETC

1325M0

Peripheral IC
ETC

1325M1

Peripheral IC
ETC

1325M2

Peripheral IC
ETC