D9412G/D7412G  
Specifications  
Control/Communicators  
Control Features  
·
Eight programmable areas, each with  
perimeter/interior partitioning. Regular, master,  
associate, or shared option by area  
·
·
Real-time clock and test timer  
Up to 1000-event log, including time, date and  
event with area, point and user number  
·
Battery charging circuit; AC power, voltage and  
ground fault supervision  
·
·
Automatic reset circuit protectors  
On-board CPU watchdog warning buzzer and  
diagnostic LEDs  
·
·
Lightning and EMI protection  
Power limited external circuits  
User Interface  
·
Supervises up to 8 command centers (up to 32  
non-supervised command centers can be used)  
Communicator  
·
·
·
·
Custom command center text  
D7412G: 4 custom functions  
D9412G: 16 custom functions  
·
·
·
·
Built-in digital communicator with phone line  
monitor (loop or ground start)  
Multiple telephone numbers, primary and duplicate  
paths with main and alternate destinations  
Full function command menu including custom  
functions  
All reports within each 4 route groups are  
programmable  
·
·
·
D7412G: 99 Users  
D9412G: 249 Users  
Optional dual phone line switcher monitors 2 phone  
lines  
Each user has authority by area and 16-character  
name  
·
·
Automatic test and status reports  
Time windows for arming and open/close report  
suppression  
·
14 custom authority levels control user’s authority  
to change, add, delete passcodes or access control  
tokens/cards, disarm, bypass points, initiate system  
tests, and more  
·
Programmable answering machine work-around for  
remote programming on shared phone line  
·
Adjustable brightness/loudness for command  
center display/ sounder  
Programmable Outputs  
·
·
·
·
·
·
·
2-amp alarm power @ 12 VDC  
1.4-amp aux power @ 12 VDC  
4 alarm output patterns  
·
·
D7412G: 1 parallel printer  
D9412G: 3 parallel printers  
Access Control  
Automatic bell test  
·
·
·
·
·
D7412G: 2 access control doors and 396  
tokens/cards  
Programmable bell shut-off timer  
D7412G: 67 programmable outputs  
D9412G: 131 programmable outputs  
D9412G: 8 access control doors and 996  
tokens/cards  
Custom door strike, point shunt and auto disarming  
response by area  
System Response  
·
D7412G: 75 points, 8 on-board, up to 67 off-board  
Logging options for: Access Granted, No Entry,  
Request to Exit and Request to Enter  
·
D9412G: 246 points, 8 on-board, up to 238 off-  
board  
14-panel wide access levels with both manual and  
scheduled control  
·
·
·
·
·
·
31 custom point indexes, including fire supervisory  
Selectable point response time  
Fire alarm verification  
Fire inspector’s local test  
Watch mode  
Scheduled events (Skeds) arm, disarm, bypass and  
unbypass points, control relays, control authority  
levels, control door access and more  
D9412G/D7412G  
System Description  
D9412G/D7412G Control/Communicators provide an  
integrated solution to Access Control, Security, and Fire  
Alarm System applications.  
Each user may have a 16-character customized name  
that may be viewed, printed, reported to a central station  
in Radionics’ Modem IIIa2 Communications format or  
retrieved with Remote Account Manager (RAM).  
Control/Communicators are capable of monitoring alarm  
points for intruder or fire alarms while operating user  
command centers, (access readers, door locks -  
D7412G/ D9412G), and other outputs. Includes a built-  
in digital communicator, which reports events to  
selected destinations via 4 programmable route groups.  
Security and Fire Detection  
D9412G/D7412G provide eight “on-board” detection  
points, and up to 238 additional off-board points  
(depending on Model and expansion interfaces). Points  
may be individually programmed and used to monitor all  
types of burglar alarm, fire alarm, and supervision  
devices.  
Programming and accessory modules offer flexibility  
and beneficial features rarely found in other security  
control systems.  
Communications  
D9412G/D7412G have four route groups, sort reports  
by priority and are capable of transmitting reports to up  
to four locations. Each group has a programmable  
primary and backup destination. Compatible with D6600  
NetCom Communications System using a D9133TTL-E  
Ethernet Interface Module. Radionics’ Modem IIIa2  
Communications Format, available with Radionics’  
receiver, adds these reporting capabilities. To name just  
a few:  
Area Configurations  
D9412G/D7412G area programming offers you a wide  
selection of different system configurations. Each area  
is assigned an account number to define annunciation,  
control, and reporting functions. Multiple areas can be  
linked to a shared area which is automatically controlled  
(hallway or lobby). Area arming can be conditional on  
other areas (master/associate).  
User Interface  
·
·
·
·
·
Individual point numbers and text  
Opening/Closing reports by area number  
Remote programming attempts  
Diagnostic reports  
D9412G/D7412G command centers provide on-  
premises point and system status annunciation. A fully  
selectable user interface can customize command  
center displays and simplify operation by creating menu  
items and functions, appropriate only to that command  
center.  
Access control events with user name  
Event Log Storage, Viewing and Printing  
Function Lists can help a user become familiar with the  
operation of the control panel.  
D9412G/D7412G event log automatically stores up to  
1000 events. All local and transmitted events are stored  
(some access events are selectable). Event log includes  
time, date and event, with area, point and user number.  
Users may view event log from Alpha Command  
Custom functions allow users to perform complex  
functions with a few keystrokes. Each may be  
programmed and identified by 16 characters of custom  
text and contain up to 32 keystrokes.  
Centers. Events may be retrieved remotely using RAM.  
Events are printed as they are stored in event log.  
D9131A Parallel Printer Interfaces can be installed to  
record events locally on one, two, or three printers  
(depending on model). Each can print opening and  
closing, access, alarm, Skeds, or any combination of  
events. Each can print information from any combination  
of areas. Each can supervise various printer status  
conditions.  
D1255 Command Center, D1256 Fire Alarm Command  
Center and D1257 Fire Alarm Annunciator use a 16-  
character English language display to show system  
status, area status (custom text), and point status  
(custom text). D720 8-point LED area command center  
provides command functions and annunciation for up to  
8 points in a single area. Any combination of these  
command centers may be used within the same area.  
Event log and local printer are ideally suited for  
customers who like to have a record of openings and  
closings without having extra communications costs.  
Logger and RAM, can suppress reports and then  
retrieve events periodically using one phone call, rather  
than receiving several calls each day.  
Easy to remember commands like Command 1,  
Command 2, and Command 8 make an easy transition  
for seasoned Radionics users.  
User Passcodes  
D9412G/D7412G can accommodate:  
·
D7412G: 99 user passcodes  
D9412G: 249 user passcodes.  
(Each passcode individually programs with 3 to 6  
digits in length and no fixed digits).  
When the panel’s event log reaches its programmed  
threshold of stored events, it can send a report to a  
receiver to remind central station to retrieve events from  
the panel’s event log with RAM.  
Each user is assigned one of 14 customized authority  
levels in each area. You may restrict passcodes to  
operate only during certain times.  
D9412G/D7412G Specifications  
Page 2  
© 2001 Radionics  
47487B  
D9412G/D7412G  
D9210B Access Control Interface Module  
Scheduled Events (Skeds)  
Access is granted from Wiegand format readers or  
Request to Enter/Exit devices when connected to the  
D9210B.  
D9412G/D7412G internal clock and calendar help the  
panel operate individual scheduled events (Skeds).  
Skeds perform a specific function (such as arm/disarm,  
relay control, point bypassing, etc.). Each Sked is  
programmed for a time and day-of-week schedule or a  
date-of-year schedule.  
Also provided are connections for door point, strike,  
buzzer and enclosure tamper. (One D9210B required  
per door).  
Users may change Sked Time if programmed for local  
time editing. Holiday schedules can enable or disable  
individual Skeds during holiday periods.  
·
·
Each access door can be configured independently  
Door point controls access door and is part of alarm  
system (door does not need double contacts)  
·
64 scheduled events with up to 26 different  
functions  
·
·
·
Door contact can reset strike time when opened  
Door contact can terminate entry buzzer (if used)  
·
·
Day-of-week or date-of-year schedules  
Door contact is shunted when valid access is  
granted  
Four holiday schedules of 366 days each (leap  
year)  
·
·
·
·
·
Optional buzzer can trigger prior to end of door  
shunt period, warning user a “door left open”  
condition is about to occur  
Fire Test  
D9412G/D7412G Fire Test Mode suppresses reports to  
the central station receiver so you can test initiating and  
indicating devices without transmitting alarms. Initiating  
Fire Test Mode, sends “Fire Walk Start” to central  
station indicating start of test. Test events become “local  
only.” Command center shows how many points are to  
be tested.  
Door point can be configured to generate alarm or  
trouble (or have no response) when door is left  
open beyond shunt period  
In addition to granting access, cards control  
whether system will disarm along with granting  
access  
Door strike can release automatically during  
disarmed periods, then automatically re-lock when  
area is armed  
Each time a device initiates an alarm, programmed point  
text displays at command center and the fire bell rings  
for 2 seconds. Automatic sensor reset feature allows  
continued testing of devices without time consuming  
trips to manually reset sensors. At the end of test,  
command center displays the number of untested  
points. You can also view point text for each untested  
point.  
Door can generate an alarm, trouble, (or have no  
response) depending on area’s armed condition  
when door is opened outside authorized access  
period  
·
·
REQUEST TO ENTER and REQUEST TO EXIT  
can be programmed to shunt door without  
activating strike  
Ending Fire Test Mode, sends “Fire Walk End” to the  
central station receiver indicating end of test.  
An option determines whether access granted, no  
entry, request to enter, or request to exit messages  
are sent to event log  
Combining Access Control with Security and Fire  
Detection (D7412G/D9412G)  
D9412G/D7412G combined systems can help prevent  
false alarms making it easy to use one system that  
controls access, security, and fire functions.  
RAM IV and RAM IV Lite  
These account management and panel-programming  
utilities allow computers equipped with the Microsoft®  
Windows® operating system and a modem to act as a  
remote programming, record storage, remote control  
and troubleshooting tool for the D9412G/D7412G  
Control/Communicators. To enhance the down/upload  
capabilities RAM can be used in a TCP/IP and Dynamic  
Host Communication Protocol (DHCP) configuration.  
Access control features of D7412G/D9412G can deny  
access during armed periods, grant access only to  
certain authorized users depending whether an area is  
master armed, perimeter armed or disarmed. Alarm  
system can automatically disarm when designated  
authorized users are granted access.  
·
D7412G: Two (2) access doors; 75 detection  
points; 396 Token/Users  
·
D9412G: Eight (8) access doors; 246 detection  
points; 996 Token/Users  
D9412G/D7412G Specifications  
Page 3  
47487B  
© 2001 Radionics  
D9412G/D7412G  
be equipped with a 16-character alphanumeric display,  
distinct fire and burglary tones, and backlighted multi-  
key touchpad.  
Specifications  
General  
Contractor shall furnish and install, where indicated on  
plans, a Radionics D9412G/D7412G  
Control/Communicator. Panel shall be listed by  
Underwriters Laboratories for NFPA 72 Applications.  
D1255, D1256, and D1257 shall have the ability to  
display for each detection point: alarm, trouble,  
supervisory, or faulted, and custom text. In addition,  
expanded, addressable point displays shall include  
missing and extra point information. System-wide  
displays shall include: local system test, sensor reset,  
fire test mode, and user programming prompts.  
D9412G/D7412G shall support initiating and indicating  
modules and Radionics Command Centers. Power  
supply shall provide 1.4-amp @12 VDC for all  
processing functions and auxiliary requirements.  
Fire Test  
D9412G/D7412G Fire Test Mode shall support single-  
person operation. All reports to central station shall be  
suppressed while fire test is being conducted. Fire Test  
Mode shall be activated by entering a user passcode at  
a command center. All testing data shall be visible on  
command center and annunciator displays during  
testing.  
Software  
D9412G/D7412G programming of all system functions  
shall be accomplished on site using Radionics’ Hand-  
held D5200 Programmer or remotely using a RAM  
software package. A programmable system passcode  
shall be used to prevent unauthorized remote  
programming.  
Hardware  
Panel shall accommodate up to four separate telephone  
numbers for primary, alternate and backup receivers,  
automatic test reports, selective relay activation, and  
custom text on associated command centers and  
annunciators.  
D9412G/D7412G shall provide up to 246 individually  
identified addresses, (75 with D7412G). Each shall  
accommodate normally open and/or normally closed  
devices with end-of-line resistor supervision. Each point  
shall be programmable for fire, fire supervisory or  
burglary applications. Point output shall be silent or  
audible. Audible output shall be steady, pulsed, CA  
standard, or temporal code 3.  
When resetting alarms, arming or disarming a  
combination fire/burglary and/or access control system,  
the user shall be identified by name and number.  
External Hardware  
D7212/D7412G: Up to 99 users  
D9112/D9412G: Up to 249 users  
D9412G/D7412G shall allow use of up to three on-site  
parallel printers (one with D7412G), using Radionics  
D9131A Printer Interface Modules. Events shall print  
time, date, and event description with area, account,  
point, and user number, including text for points and  
users.  
Panel’s internal clock shall support Skeds (scheduled  
events) feature. User shall have option to alter Sked  
activation times using a programmable passcode.  
Up to 64 programmable, scheduled event functions shall  
be available for controlling relays, enabling passcodes,  
windows, and supporting service alert feature.  
Installation, Warranty, and Training  
D9412G/D7412G System Installation, wiring of initiating  
devices and signaling circuits, shall be the responsibility  
of installing company.  
Other programmable functions shall include fire alarm  
reset commands, and day/date/time adjustments.  
Event Logger/Clock  
Warranty on all components shall be two years, subject  
to manufacturer’s limitations. Training on complete  
system operation shall be furnished by installing  
company upon completion of installation.  
D9412G/D7412G event log shall store up to 1000  
events. All system events shall include time, date and  
event with area, point and user number.  
Access events (optional) stored shall include: Access  
granted, No Entry, Request To Enter, and Request To  
Exit. Logger records certain functions entered at  
command centers. Stored events in Logger shall be  
retrievable with a RAM software package.  
Remote Diagnostics and Controls  
D9412G/D7412G shall be able to be remote controlled  
through use of RAM software. Features shall include:  
reset of audible signals, activation/deactivation of D8129  
relays, interrogation of battery, point and armed status,  
enabling or disabling reporting functions, and shunting  
of reporting points during servicing.  
Command Centers  
D9412G/D7412G command centers shall be Radionics  
D1255 Command Center, D1256 Fire Alarm Command  
Center and D1257 Fire Alarm Annunciator. Each shall  
D9412G/D7412G Specifications  
Page 4  
© 2001 Radionics  
47487B  
D9412G/D7412G  
Accessories/Ordering Information  
Model  
Description  
Model  
Description  
Command Centers, Keypads and Accessories:  
Fire Alarm Modules and Accessories:  
D1255  
D1256  
D1257  
D720  
D268  
D269  
D279  
D54B  
D54C  
D55  
Command Center  
D125B  
D129  
D130  
D184  
D185  
Dual Class B Powered Loop Interface Module  
Fire Alarm Command Center  
Dual Class A Initiation Circuit Module  
Auxiliary Relay Module, 12/24 VDC  
Auxiliary Local Energy Interface Kit  
Reverse Polarity Interface Module  
Fire Alarm Annunciator  
8 Point LED Area Command Center  
Independent Point Control Module  
Independent Point Control Keypad  
Independent Point Control  
D192C N.A.C. Module, Class B, 12/24 VDC, 1.8-amp  
D192D N.A.C. Module, Class A/B, 12/24 VDC, 3-amp  
Command Center Flush Mount Kit, Brass  
Command Center Flush Mount Kit, Stainless  
Command Center Desk Stand  
Command Center Surface Mnt. Conduit Box  
D928  
Dual Phone Line Switcher  
Release Module  
D8130  
Power Supplies, Transformers, Batteries &  
Accessories:  
D56  
D9142F Auxiliary Power Supply, 24 VDC, 4-amp  
Zone Expansion and Interface Modules:  
D8125 POPEX Module  
D8132  
D1640  
D113  
Battery Charger Module, 12 VDC  
16.5 VAC 40 VA Transformer  
Battery Lead Supervision Module  
Dual Battery Harness/Long Leads  
Battery, 12 V, 7.5 Ah  
D9127U/T POPIT Module, U=No Tamper /  
T= Tamper  
D8128C  
D940  
OctoPOPIT Module  
D122/L  
D126  
Super Loop Module  
D8129  
D127  
OctoRelay Module  
D1218  
Battery, 12 V, 17.2 Ah  
Reversing Relay  
Enclosures, Brackets, and Phone Cords:  
D136  
Plug-in Relay  
D8103  
D8109  
D8108A  
D8004  
D137  
Universal Enclosure  
D8121A  
D8122  
D9131A  
D9210B  
Derived Channel S.T.U. Non UL  
Derived Channel S.T.U. UL Listed  
Parallel Printer Interface Module  
Access Control Interface Module  
Fire Enclosure  
Attack Resistant Enclosure  
Transformer Enclosure  
Module Mounting Bracket  
Lock and Key for D8103  
Detection Devices with Built-in POPIT:  
D101  
ZX835  
PIR/Microwave Detector, 35 x 35 ft.  
(10.7 x 10.7 m)  
D161/162  
Dual Mod. Telephone Phone Cord, 7 ft.  
(2.1 m) / 2 ft. (61 cm)  
ZX970  
PIR/Microwave Detector, 60 x 60 ft.  
(18.3 x 18.3 m)  
Programming Products:  
D5200  
Hand-held Programmer  
ZX935Z  
ZX776Z  
ZX794  
PIR Detector, 35 x 35 ft. (10.7 x 10.7 m)  
PIR Detector, 50 x 50 ft. (15 x 15 m)  
PIR Detector, 90 x 90 ft. (27 x 27 m)  
Remote Account Manager, RAM IV  
D5500-  
####*  
D5500-  
####*-  
LTE  
RAM IV Lite  
ZX938Z  
PIR Detector, Ceiling Mount, 360° x 60 ft.  
(18 m)  
* #### represents the version number of the software.  
Order Processing has the latest revision information.  
D278S  
D298M  
D298S  
Smoke Detector Base 12 VDC  
Smoke Detector Base, Master, 24 VDC  
Smoke Detector Base, 24 VDC  
D9412G/D7412G Specifications  
Page 5  
47487B  
© 2001 Radionics  
D9412G/D7412G  
Listings and Approvals  
Fire  
·
UL: Central Station, Local, Auxiliary, Remote  
Station, and Household Fire Warning.  
·
CSFM: Approved for highrise and non-highrise.  
Burglary  
·
UL: Central Station, Local, Police Connect, Bank  
Safe and Vault, Mercantile Safe and Vault, and  
Grade A Household  
·
DOD: Approved for installations in Sensitive  
Compartmented Information Facilities (SCIF).  
Access  
·
UL: Access Control Systems.  
D9412G/D7412G Specifications  
© 2001 Radionics  
Page 6  
47487B  
D9412G/D7412G  
Notes  
D9412G/D7412G Specifications  
47487B  
Page 7  
© 2001 Radionics  
© 2001 Radionics, a division of Detection Systems, Inc.  
PO Box 80012, Salinas, CA 93912-0012, USA  
Customer Service: (800) 538-5807  
47487B  
Specifications  
7/01  
D9412G/D7412G  
Page 8 of 8  

相关型号:

D7212

Fire Command Center, Fire Annunciator
ETC

D721S

Schnelle Gleichrichterdiode Fast Diode
EUPEC

D721S45T

Schnelle Gleichrichterdiode Fast Diode
EUPEC

D721S45TXPSA1

Rectifier Diode, 1 Phase, 1 Element, 1080A, 4500V V(RRM), Silicon,
INFINEON

D7220D

High-Performance Graphics Display Controller
NEC

D7225-1

MEMORY CONTROLLER
ETC

D7225-6

MEMORY CONTROLLER
ETC

D7231

THE SMALL SCREEN VERTICAL DEFLECTION DRIVER
ETC

D72863-000

Electric Fuse, 1.25A, 600VAC, 250A (IR), Surface Mount, ROHS COMPLIANT
LITTELFUSE

D72F5T1

TRANSISTOR | BJT | NPN | 50V V(BR)CEO | 5A I(C) | TO-251AA
ETC

D72F5T2

TRANSISTOR | BJT | NPN | 50V V(BR)CEO | 5A I(C) | TO-252AA
ETC

D72FY4D1

TRANSISTOR | BJT | DARLINGTON | NPN | 80V V(BR)CEO | 4A I(C) | TO-251AA
ETC