DET4TC2 [ETC]

Digital Ground Testers;
DET4TC2
型号: DET4TC2
厂家: ETC    ETC
描述:

Digital Ground Testers

文件: 总3页 (文件大小:259K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DET4TC2 & DET4TCR2  
Digital Ground Testers  
DET4TC2 & DET4TCR2  
Digital Ground Testers  
I IP54 rated  
I 2, 3 and 4 point testing  
I Attached Rod Technique (ART)  
I Stakeless measurements  
I User selectable test frequency  
I Dry cell or rechargeable versions  
I User selectable output voltage  
I Simple one button operation  
I Robust carry case  
I Backlit display  
I Delivered with calibration certificate  
true stakeless measurements to be made in situations where  
driving stakes is not practical.  
DESCRIPTION  
Megger’s DET4 family of ground testing instruments offers  
a comprehensive solution to your ground stake and soil  
resistivity testing needs. The basic kit option comprises, the  
instrument, test leads, stakes, batteries and calibration cer-  
tificate are delivered in a tough carry case which has space  
to accommodate all the instrument accessories - everything  
you need to start testing in one kit.  
The clear, easy-to-read display provides excellent contrast  
and viewing angle making the instrument ideally suited  
to outdoor use. The display is backlit, extending the  
operational environment of the instrument to cable cellars  
and other dark locations.  
The instrument offers a wide measurement range of 0.01  
to 200 k, ground noise voltage measurement from 1 V to  
100 V and ground current from 1 mA to 20 A. Accurate  
results can be obtained in electrically noisy environments  
since the instrument is capable of rejecting noise voltages  
of 40 V peak to peak and the user can select different test  
frequencies to minimise the effect of interference.  
The DET4TC2 and DET4TCR2 are designed for extended  
temperature range use with an IP54 rated enclosure making  
them genuinely outdoor instruments. The instrument  
provides all the functions required for ground system  
testing: variable frequency 2 pole, 3 pole, 4 pole, Attached  
Rod Technique (ART), stakeless, leakage current and ground  
noise voltage measurement.  
The DET4TC2 Digital Ground tester is powered from 8 AA  
batteries which are widely available and deliver excellent  
testing time. The DET4TCR2 is powered from rechargeable  
AA cells. The battery charger is built in and the instrument is  
supplied with an AC/DC adaptor. For both instruments, the  
battery status is display using a bar-graph.  
The instrument is easy to use with a large rotary selector  
switch and one-press test button, both of which permit  
operation with gloved hands. Unlike some instruments, the  
design negates the need for a shorting link when making  
two pole measurements. There are no hidden functions  
with the instrument: clearly labelled auxiliary controls are  
used to select the test frequency (94 Hz, 105 Hz, 111 Hz and  
128 Hz), output voltage (50 V or 25 V where local standards  
apply) and to switch the backlight on or off.  
The Megger ground testers comply with stringent safety  
standards and are rated to 100 V CAT IV. They also have  
selectable 25 V or 50 V output for compliance with IEC  
61557-5.  
The optional ICLAMP augments the traditional fall-of-  
potential measurement method with ART (Attached Rod  
Technique) which allows electrode testing without  
disconnection and also leakage current measurements down  
to 1 mA. A second optional clamp, the VCLAMP, enables  
DET4TC2 & DET4TCR2  
Digital Ground Testers  
Safety  
SPECIFICATIONS  
Complies with the requirements of IEC61010-1 100V CAT IV  
between terminal pairs.  
Ingress protection  
IP54  
EMC  
C stake, P stake and Noise check  
Automatic  
In accordance with IEC61326-1  
Standards Compliance  
Complies with the requirements of KEMA K85B  
Noise rejection  
40 V pk to pk  
Complies with the following parts of EN61557, “Electrical safety in  
low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. -  
Equipment for testing, measuring or monitoring of protective  
measures”.  
2-wire, 3-wire, 4-wire test  
Yes, no shorting links required  
No disconnect testing (ART)  
Yes, with ICLAMP  
Part 1 - General requirements  
Part 5 - Resistance to earth  
Stakeless measurement  
Yes, with ICLAMP and VCLAMP  
Dimensions  
203 mm x 148 mm x 78 mm (8in x 5.8in x 3in)  
Instrument output  
Voltage: 25 V or 50 V at 94 Hz, 105 Hz, 111 Hz and 128 Hz  
Current: 4.5 mA or 0.45 mA or 0.045 mA  
Weight  
1kg (2.2lb)  
Ground current range with clamp  
0.5 mA to 19.9 A  
Ground current accuracy  
5% 3 digits  
Ground voltage range  
0 to 100 V ac  
Ground voltage accuracy  
2% 2 V  
Resistance range  
0.01 to 200 kΩ  
Resistance accuracy  
2P measurements: 2% 3 digits  
3P measurements: 2% 3 digits  
4P measurements: 2% 3 digits  
ART measurements: 5% 3 digits  
Stakeless measurements: 7% 3 digits  
Maximum probe resistance  
Rp limit: 200 k(50 V output voltage)  
Rc limit: 200 k(50 V output voltage)  
Limits reduced to 100 kfor 25 V output voltage  
Limits reduced to 5 kfor 0.01 resolution  
Display  
31⁄  
digit high contrast liquid crystal, backlit  
2
Battery type  
DET4TC2: 8 off AA (LR6) cells  
DET4TCR2: 8 off AA (LR6) NiMH rechargeable cells  
Operating temperature range  
-15°C to +55°C / 5°F to 131°F  
Storage temperature range  
-40°C to +70°C / -40°F to 158°F  
DET4TC2 & DET4TCR2  
Digital Ground Testers  
ORDERING INFORMATION  
Item  
Order Code.  
1000-345  
Item  
Order Code.  
5410-429  
DET4TC2 Basic kit  
Accessories  
DET4TCR2 Basic kit (rechargeable)  
“Basic kit” included Accessories  
Hard carry case  
1000-346  
Replacement hard carry case  
Replacement calibration check PCB  
(two-clamp measurements)  
6220-831  
Stake and wire kit (15m, 10m, 10m, 3m)  
External AC/DC charger (DET4TCR2 only)  
Replacement ground test stakes (x2)  
for included kit (200mm, 8mm dia)  
Replacement ground test leads (x4)  
for included kit (15m, 10m, 10m, 3m)  
Replacement auger stake  
6220-804  
6220-806  
6220-839  
1000-349  
1000-350  
1000-362  
1000-361  
DET4TC2 + adaptors  
1000-402  
1000-403  
DET4TCR2 + adaptors (rechargeable)  
“+ adaptors” included Accessories  
Hard carry case  
for professional kit  
Replacement cable reel (50m, red cable)  
for professional kit  
Right angle terminal adaptors  
(to connect bare wires to terminals)  
External AC/DC charger (DET4TCR2 only)  
Replacement cable reel (50m, black cable)  
for professional kit  
Replacement cable reel (30m, green cable)  
for professional kit  
Kitted options for ART and Stakeless testing  
DET4TC2 + clamps  
1000-365  
1000-366  
Replacement cable reel (30m, yellow cable)  
for professional kit  
DET4TCR2 + clamps (rechargeable)  
“+ clamps” included Accessories  
Hard carry case  
Replacement external AC/DC adaptor  
(DET4TCR2 only)  
6280-370  
ICLAMP  
Stake and wire kit (15m, 10m, 10m, 3m)  
ICLAMP (for ART testing)  
Current clamp and connecting lead  
Calibration check box (25 Ohm)  
Right angle terminal adaptor set  
Black crocodile clip (1)  
6220-824  
6220-803  
6220-850  
VCLAMP (adds stakeless testing)  
Field calibration check for instrument and CLAMPS  
Right angle terminal adaptors (to connect bare wires  
to terminals)  
Professional groung testing kit (2 x 50m, 2 x 30,  
4 auger stakes, tape measure, in hard carry case  
Vehicle 12 V socket charger (DET4TCR2 only)  
“Getting down to earth”  
6320-245  
6220-375  
External AC/DC charger (DET4TCR2 only)  
Professional kitted options for ART and Stakeless testing  
Megger guide to earth ground testing  
21500-072  
DET4TC2 + kit  
1000-404  
1000-405  
DET4TCR2 + kit (rechargeable)  
“+ kit” included Accessories  
Hard carry case  
Stake and wire kit (15m, 10m, 10m, 3m)  
ICLAMP (for ART testing)  
VCLAMP (adds stakeless testing)  
Field calibration check for instrument and CLAMPS  
Right angle terminal adaptors (to connect bare wires  
to terminals)  
External AC/DC charger (DET4TCR2 only)  
Separate professional ground testing kit (2 x 50m,  
2 x 30m, 4 auger stakes, tape measure, in hard carry case  
Registered to ISO 9001:2000 Cert. no. Q 09290  
Registered to ISO 14001-1996 Cert. no. EMS 61597  
UK  
UNITED STATES  
4271 Bronze Way  
Dallas TX 75237-1088 USA  
OTHER TECHNICAL SALES OFFICES  
Norristown USA, Sydney AUSTRALIA,  
Toronto CANADA, Trappes FRANCE,  
Kingdom of BAHRAIN, Mumbai INDIA,  
Johannesburg SOUTH AFRICA, Conjure  
THAILAND and Täby SWEDEN  
Archcliffe Road Dover  
CT17 9EN England  
DET4TC2_4TCR2_DS_en_V04  
T
F
+44 (0) 1304 502101  
+44 (0) 1304 207342  
T
T
F
800 723 2861 (USA only)  
+1 214 333 3201  
+1 214 331 7399  
www.megger.com  
Megger is a registered trademark  
E UKsales@megger.com  
E USsales@megger.com  

相关型号:

DET4TCR2

Digital Ground Testers
ETC

DET801

SOUNDERS SMD ELECTRO-MAGNETIC AUDIO TRANSDUCERS
DUBILIER

DETBH9P00

D Subminiature Connector, 9 Contact(s), Male, Solder Terminal,
ITT

DETBH9P10

D Subminiature Connector, 9 Contact(s), Male, Solder Terminal,
ITT

DETBH9P30

D Subminiature Connector, 9 Contact(s), Male, Solder Terminal,
ITT

DETF

Double-Ended Tuning Fork Sensors
STATEK

DETF_09

Double-Ended Tuning Fork Sensors
STATEK

DETN01

1W SMD Package DC-DC Unregulated Converter
MEANWELL

DETN01L-05

DC DC CONVERTER +/-5V 1W
MEANWELL

DETN01L-12

1W SMD Package DC-DC Unregulated Converter
MEANWELL

DETN01L-12-SC

1W SMD Package DC-DC Unregulated Converter
MEANWELL

DETN01L-15

DC DC CONVERTER +/-15V 1W
MEANWELL