EM4-DINAV23DOR [ETC]

Energy Management Energy Meter with plug-in Output Modules; 能源管理电能表与插件输出模块
EM4-DINAV23DOR
型号: EM4-DINAV23DOR
厂家: ETC    ETC
描述:

Energy Management Energy Meter with plug-in Output Modules
能源管理电能表与插件输出模块

文件: 总8页 (文件大小:203K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ene rg y Ma na g e m e nt  
Ene rg y Me te r w ith p lug -in O utp ut Mod ule s  
Typ e EM4 -DIN  
Class 1 (active energy)  
Class 2 (reactive energy)  
Three-phase multi-function energy meter  
Back-lighted LCD display  
31/2 DGT instantaneous variables read-out  
8 DGT + 71/2 DGT energy read-out  
Measurements of system and phase variables: W, Wdmd  
Measurements of total energies: kWh, kvarh  
Measurements of partial energies: kWh, kvarh  
Energy measurements according to EN61036 and EN61268  
Energy measurements by time periods (t1-t2-t3-t4)  
selectable by input contacts  
Measurements of m3 H2O and m3 GAS by means of input contacts  
TRMS measurements of distorted wave forms  
(voltages/currents)  
Two basic models: direct connection 20(90)AAC,  
CT 5(10)AAC and VT connection  
Self power supply (available for some models only) or  
auxiliary power supply: 24V, 48V, 115V, 230V, 50-60Hz;  
18 to 60VDC, 77 to 143VDC  
Degree of protection (front): IP 40  
Front dimensions: 9 DIN modules  
RS 422/485 Serial port by means of optional module  
Dual pulse output by means of optional module  
Alarm output (kW dmd) by means of optional module  
Digital inputs for the management of the time periods  
and of the H2O and GAS meters  
Pro d uct d e scrip tio n  
How to order  
EM4 -DIN AV5 3 X X XX  
Model  
Range code  
System  
Power supply  
Slot A  
Slot B  
Three-phase energy meter  
with built-in configuration  
key-pad; particularly indicat-  
ed for the metering and the  
management of the energy  
in addition to the metering  
and the management of the  
signals coming from the  
water and gas meters.  
Housing for DIN-rail or wall-  
mounting, IP40 (front) pro-  
tection degree.  
Completely sealable housing.  
In case of direct connection  
up to 90A, the measuring  
input terminals are suitable  
for cables with a cross-sec-  
tion area from 6 to 35 mm2.  
The special design of the  
instruments housing allows  
to add at any time the inter-  
face modules, even when  
the instrument is already Important note:  
installed. The following mod- The models from AV0 to AV7 can be equipped with any  
ules are available:  
type of available modules (slot A and B).  
- for all versions: pulse output; The models AV8 and AV9 can be equipped only with the  
- only for the versions with  
“O” and “R” type modules.  
auxiliary power supply: The AV8 and AV9 models can measure all the parameters  
digital inputs, RS485 serial  
port.  
even if the three phase system being connected is missing  
one phase.  
The AV2 model is suitable only for three-phase unbalanced  
system without neutral.  
Typ e se le ctio n  
Range Code  
Power supply  
Slot A (retransmission)  
Slot A (retransmission) cont.  
X:  
O:  
None  
R:  
AO2910 module.  
Auxiliary Power Supply:  
AV0: 208VL-L/20(90)AAC [3] A:  
AV1: 400VL-L/20(90)AAC [1]  
For all versions  
AO2900 module  
Dual open collector out-  
put. Three operating  
modes:  
One relay output + one  
open collector output.  
Operation modes like  
module AO2900  
24VAC  
-15+10%, 50-60Hz  
48VAC  
-15+10% , 50-60Hz  
115VAC  
-15+10% , 50-60Hz  
230VAC  
B:  
C:  
D:  
AV3: 660VL-L/20(90)AAC [2]  
AV4: 208VL-L/5(10)AAC [3]  
AV5: 400VL-L/5(10)AAC [1]  
AV6: 100VL-L/5(10)AAC [3]  
AV7: 660VL-L/5(10)AAC [2]  
Self Power Supply:  
AV2: 220VL-L/20(90)AAC [4]  
AV8: 208VL-L/20(90)AAC [1]  
AV9: 400VL-L/20(90)AAC [1]  
two pulse outputs  
(kWh and kvarh);  
one alarm output  
(kW dmd) and one  
pulse output  
(kWh or kvarh)  
one output  
remotely controlled  
by a serial port  
and one pulse  
-15+10% , 50-60Hz  
18 to 60VDC  
77 to 143VDC  
Slot B (retransmission)  
4:  
5:  
Only with A-B-C-D-4  
power supply  
AV2, AV8 and AV9 only  
X:  
Self Power Supply  
System  
400V  
L-L  
output (kWh or kvarh)  
XX:  
S0:  
None  
(-20+15% , 50-60Hz)  
D:  
AQ2940 module  
AR2950 module  
RS422/485  
serial port  
208V  
3 :  
Three-phase,  
unbalanced load with  
or without neutral  
L-L  
Two digital inputs for  
the management of  
water and gas meters  
(-20+15% , 50-60Hz)  
220V  
L-L  
(-10+15% , 50-60Hz)  
[1] Un: -20+15% [2] Un: -30+15% [3] Un: -20+20% [4] Un: -10 +15%  
Specifications are subject to change without notice EM4-DINDS1003  
1
EM4-DIN  
In p ut sp e cifica tio ns  
Number of inputs  
Current  
Voltage  
Temperature drift  
Sampling rate  
Display  
200ppm/°C  
3
4
1000 samplings/s @ 50Hz  
Accuracy (display, RS485)  
Ib: 5A, Imax: 10A  
Type  
Back-lighted LCD  
Ib: 20A, Imax:90A  
Un: see “Range code” on  
previous page  
from 0.003Ib to 0.2Ib:  
±(0.5%RDG +3DGT)  
from 0.2Ib to Imax:  
±(0.5%RDG +1DGT)  
Instantan. variables read-out  
Energies  
31/  
2
DGT  
Total: 8 DGT + 71/  
Partial: 8 DGT + 71/  
2
DGT;  
DGT;  
2
Current  
Max. and Min. indication  
Measurements  
Max. 1999 (99999999), Min. 0  
Power, energy.  
TRMS measurements of  
distorted wave forms.  
Direct  
Voltage  
in the range Un:  
±(0,5% RDG + 1DGT)  
±0.1% RDG (50 to 60 Hz)  
Coupling type  
Frequency  
Crest factor  
Active power  
Ib 5A  
Ib 20A  
3 (15A max. peak)  
6 (127A max. peak)  
(@ 25°C ± 5°C, R.H. 90%) ±(1% RDG +1DGT). PF 1,  
0.1Ib to Imax, in the Un range;  
Current overload  
PF 0.5L, PF 0.8C, 0.2Ib to  
Imax, in the Un range  
5(10) A, for 10ms  
5(10) A, for 500ms  
5(10) A, permanent  
20(90) A, for 10ms  
20(90) A, permanent  
300A max, @ 50Hz  
200A max, @ 50Hz  
10A, @ 50Hz  
2700A max, @ 50Hz  
90A, @ 50Hz  
Energies  
(@ 25°C ± 5°C, R.H. 90%) Class 1 acc. to EN61036  
Class 2 acc. to EN61268  
Ib: 5A, Imax: 10A  
0.1Ib: 500mA,  
Voltage overload  
Permanent  
For 1s  
Start up current: 20mA  
Un: see table “range code”  
Ib: 20A, Imax: 90A  
1.2 Un  
2 Un  
Input impedance  
0.1Ib: 2A,  
400VL-L (AV1-AV5-AV9)  
208VL-L (AV0-AV4-AV8-AV2)  
660VL-L (AV3-AV7)  
100VL-L (AV6)  
5(10) A (AV4-AV5-AV6-AV7)  
> 720KΩ  
> 720KΩ  
> 1.97MΩ  
> 400KΩ  
< 0.3VA  
Start up current: 80mA  
Un: see table “range code”  
Additional errors  
Wave form  
Voltage asymmetry  
Magnetic induction  
HF Electromagnetic fields  
Operation of accessories  
Acc. to EN61036, EN61268  
<1% (3rd harmonic: 10%)  
< 0.5% (referred to Un)  
0 (up to 0.5 mT)  
< 1%  
20(90) A (AV0-AV1-AV3-AV8-AV9) < 4VA  
20(90) A (AV2)  
< 4VA  
Frequency  
50 to 60 Hz  
0
In te rfa ce m o d ule sp e cifica tio ns  
RS422/RS485 (on request)  
AR2950 module  
2000 V output to  
RMS  
Type  
Multidrop  
supply input  
bidirectional (static  
and dynamic variables)  
2 or 4 wires, max. distance  
1200m, termination directly  
on the module  
Digital outputs (on request)  
AO2900 module  
To be used as energy  
retransmission, water and  
gas, remote static outputs  
and alarm. Three working  
modes are selectable:  
two pulse outputs  
Connections  
Addresses  
Protocol  
Data (bidirectional)  
Dynamic (reading only)  
255, selectable by key-pad  
MODBUS/JBUS  
(kWh and kvarh);  
Phase and system variables:  
see table “Display pages”  
All the programming data,  
reset of energy, activation of  
static output.  
Stored energy (EEPROM)  
max. 99.999.999 kWh/kvarh  
1 start bit, 8 data bit,  
no parity, 1 stop bit  
one alarm output (kW  
dmd) and one pulse  
output (kWh or kvarh);  
one output remotely con-  
trolled by means of the  
serial port and one pulse  
output (kWh or kvarh)  
Static (writing only )  
Data format  
Pulse outputs  
Number of outputs  
Number of pulses  
2
Baud-rate  
Insulation  
9600 bit/s  
By means of optocouplers,  
2000 VRMS output  
From 0.01 to 100 pulses  
programmable according to  
the selected CT and VT ratios  
Open collector (NPN transistor )  
VON 1.2 VDC / max. 100 mA  
to measuring inputs  
Output type  
2
Specifications are subject to change without notice EM4-DINDS1003  
EM4-DIN  
Inte rfa ce m o d ule sp e cifica tio ns (co n t.)  
VOFF 30 VDC max.  
220 ms (ON), 220 ms (OFF)  
According to DIN43864  
supply input.  
Pulse duration  
Alarm output  
Insulation between the two  
outputs: 2000 V  
RMS  
Digital inputs (on request)  
AQ2940 module  
Number of outputs  
1
Four working modes are  
selectable:  
total and partial energy  
meters (kWh and kvarh)  
without the use of digital  
inputs  
total and partial energy  
meters (kWh and kvarh)  
managed by time periods  
(t1-t2-t3-t4);  
total energy meters  
(kWh, kvarh) and total  
day-time/night” GAS  
meter;  
Alarm type  
Setpoint adjustment  
Up alarm, down alarm.  
0 to 100% of the electrical  
scale  
0 to 100% of the electrical  
scale  
0 to 255 seconds  
700 ms  
Open collector (transistor NPN)  
VON 1.2 VDC / max. 100 mA  
VOFF 30 VDC max.  
By means of optocouplers,  
Hysteresis  
On-time delay  
Response time  
Output type  
Insulation  
2000 V outputs to  
RMS  
measuring inputs,  
2000 V output to  
RMS  
total energy meters  
(kWh, kvarh), GAS  
and WATER meters;  
supply input.  
Insulation between the two  
outputs: functional  
Relay + open collector  
output. Working mode like  
AO2900.  
One static output+one relay  
output, other characteristics  
like AO2900.  
Number of inputs  
Input frequency  
Duty cycle  
Prescaler adjustment  
Contact measur. voltage  
2
AO2910 module  
20Hz max.  
50%  
from 0,1 to 100,0 m3/ pulse  
12V < +Aux < 24VDC  
Logic status:  
Pulse output  
OFF < 2V, ON > 10V  
15mA max  
1kΩ  
1k, close contact  
100k, open contact  
By means of optocouplers,  
Alarm output  
Output type  
Only relay output, other  
characteristics like AO2900.  
Static type like module  
AO2900;  
Contact measur. current  
Input impedance  
Contact resistance  
Relay type: SPDT,  
Insulation  
AC1, AC15: 1AAC @250VAC  
2000 V digital inputs to  
Insulation  
2000 V outputs to  
RMS  
RMS  
measuring inputs,  
measuring inputs,  
2000 V output to  
2000 V digital inputs to  
RMS  
RMS  
supply input.  
So ftw a re functio ns  
to 5A)  
Password  
Numeric code of max.  
3 digits  
Display  
2 protection levels of the  
programming data  
Password “0”, no protection  
Password from 1 to 1000,  
all data are protected  
Variables  
Up to 4 variables per page  
Page 1:  
kWh-kvarh  
1st level  
2nd level  
Page 2a: k Wh (t1-t2-t3-t4)  
k varh (t1-t2-t3-t4)  
Page 2b: GAS m3 day-time tariff,  
GAS m3 night tariff  
Page 2c: H2O m3, GAS m3  
Page 3: WL1  
Transformer ratio  
CT  
VT  
1 to 5000  
1.0 to 199.9 and 200 to 1999  
Note: The CT ratio * VT ratio  
mustnever exceed the  
value 5000. The current  
measuring inputs can  
manage CTs with a  
Page 4: WL2  
Page 5: WL3  
Page 6: Wdmd  
Phase sequence, serial  
communication status, wrong  
connection of current  
measuring inputs.  
Errors  
secondary of 1A and 5A  
(accuracy always refers  
Sup p ly sp e cifica tio ns  
Self supplied version  
400V  
L-L  
Auxiliary power supply  
Energy consumption  
230VAC -15 +10%, 50-60Hz  
115VAC -15 +10%, 50-60Hz  
48VAC; -15 +10%, 50-60Hz  
24VAC; -15 +10%, 50-60Hz  
18 to 60VDC; 77 to 143VDC  
(-20% +15%, 50-60Hz)  
208V  
L-L  
(-20% +15% , 50-60Hz)  
220V  
L-L  
(-10+15%, 50-60Hz)  
7VA  
Specifications are subject to change without notice EM4-DINDS1003  
3
EM4-DIN  
Ge ne ra l Sp e cifica tio ns  
Operating  
0 to +55°C  
Pulse voltage (1.2/50µs)  
8kV (EN61000-4-5)  
temperature  
(R.H. < 90% non-condensing  
40°C)  
Standards  
Safety  
IEC60664-1  
Storage  
temperature  
-20 to +60°C  
(R.H. < 90% non-condensing  
40°C)  
Metrology  
Energy measurements:  
EN61036, EN61268.  
DIN43864  
Pulse output  
Installation category  
Insulation  
Cat. III (IEC60664)  
Approvals  
CE  
2000 VRMS between all inputs  
outputs to earth  
/
Connections 5(10) A  
Cable cross-section area  
Screw-type,  
4 mm2  
Dielectric strength  
4000 VRMS for 1 minute  
Connections 20(90) A  
Screw-type,  
Min./Max. cable cross-section area 6 mm2 / 35 mm2  
Noise rejection  
CMRR  
Min./Max. screws tightening torque 2 Nm / 6 Nm (90A inputs)  
100 dB, 48 to 62 Hz  
Housing  
Dimensions  
Material  
EMC  
162.5 x 90 x 63 mm  
ABS, NORYL, PC  
self-extinguishing: UL 94 V-0  
Burst  
4kV/level 4 (EN61000-4-4)  
Immunity to irradiated  
electromagnetic fields  
10V/m 26-1000MHz  
(EN61000-4-3)  
15kV (EN61000-4-2)  
according to CISPR 14  
and CISPR 22  
Mounting  
DIN-rail and wall  
Degree of protection  
Front: IP40  
Connections: IP20  
800 g approx. (packing included)  
Electrostatic discharges  
Radio frequency emissions  
Weight  
Disp la y p a g e s  
Variables that can be displayed  
No  
1
1st variable  
2nd variable  
Notes  
kWh  
kvarh  
2a  
2b  
2c  
3
kWh (t1 or t1-t2-t3-t4)  
kvarh (t1 or t1-t2-t3-t4) Depending on the type of selection you have chosen.  
Day-time GAS m3  
Night GAS m3  
GAS m3  
For the energy it is possible to choose the following operating mode:  
t1 partial meters or t1-t2-t3-t4 multitariff selection  
H2O m3  
WL1  
4
WL2  
5
WL3  
6
Wdmd  
dmd = demand (integration time selectable from 1 to 30 min.)  
7
Display of the serial communication status, phase sequence, wrong connection of current measuring inputs  
Used calculation formulas  
Note: RS422/RS485 “dynamic data. The variables transmitted are the ones listed in  
the table above and those mentioned in the “Display pages” of WM22-DIN data  
sheet except for: THDA, THDV, A max, Wdmdmax, and VAdmd max.  
Phase variables  
Instantaneous effective voltage  
System variables  
Consumption recording  
Equivalent system voltage  
Instantaneous active power  
Instantaneous power factor  
System reactive power  
System active power  
System apparent power  
System power factor  
(TPF)  
Note:  
Instantaneous effective current  
Instantaneous apparent power  
Instantaneous reactive power  
i = phase (L1, L2 or L3)  
P = active power  
Q = reactive power  
t1, t2 = starting and ending time  
points of consumption recording  
n = time unit  
t= time interval of consumption  
recording  
(TPF)  
n1, n2 = starting and ending discrete  
time points of consumption recording  
4
Specifications are subject to change without notice EM4-DINDS1003  
EM4-DIN  
Ava ila b le m o d e ls  
Type  
Inputs  
Power supply  
Self power supply  
Self power supply  
Self power supply  
230VAC, 50-60Hz  
230VAC, 50-60Hz  
230VAC, 50-60Hz  
115VAC, 50-60Hz  
115VAC, 50-60Hz  
115VAC, 50-60Hz  
48VAC, 50-60Hz  
Ordering code  
AG2200  
EM4-DIN AV9.3.X.  
EM4-DIN AV8.3.X.  
EM4-DIN AV2.3.x  
EM4-DIN AV1.3.D.  
EM4-DIN AV0.3.D.  
EM4-DIN AV3.3.D.  
EM4-DIN AV1.3.C.  
EM4-DIN AV0.3.C.  
EM4-DIN AV3.3.C.  
EM4-DIN AV1.3.B.  
EM4-DIN AV0.3.B.  
EM4-DIN AV3.3.B.  
EM4-DIN AV1.3.A.  
EM4-DIN AV0.3.A.  
EM4-DIN AV3.3.A.  
EM4-DIN AV5.3.D.  
EM4-DIN AV4.3.D.  
EM4-DIN AV7.3.D.  
EM4-DIN AV5.3.C.  
EM4-DIN AV4.3.C.  
EM4-DIN AV7.3.C.  
EM4-DIN AV5.3.B.  
EM4-DIN AV4.3.B.  
EM4-DIN AV7.3.B.  
EM4-DIN AV5.3.A.  
EM4-DIN AV4.3.A.  
EM4-DIN AV7.3.A.  
EM4-DIN AV6.3.D.  
EM4-DIN AV6.3.C.  
EM4-DIN AV6.3.B.  
EM4-DIN AV6.3.A.  
EM4-DIN AV1.3.4 / [5]  
EM4-DIN AV0.3.4 / [5]  
EM4-DIN AV3.3.4 / [5]  
EM4-DIN AV5.3.4 / [5]  
EM4-DIN AV4.3.4 / [5]  
EM4-DIN AV7.3.4 / [5]  
EM4-DIN AV6.3.4 / [5]  
400V , 20(90)A  
L-L  
208V , 20(90)A  
AG2201  
AG2244  
AG2202  
AG2203  
AG2204  
AG2205  
AG2206  
AG2207  
AG2208  
AG2209  
AG2210  
AG2211  
AG2212  
AG2213  
AG2214  
AG2215  
AG2216  
AG2217  
AG2218  
AG2219  
AG2220  
AG2221  
AG2222  
AG2223  
AG2224  
AG2225  
AG2226  
AG2227  
AG2228  
AG2229  
L-L  
220V , 20(90)A  
L-L  
400V , 20(90)A  
L-L  
208V , 20(90)A  
L-L  
660V , 20(90)A  
L-L  
400V , 20(90)A  
L-L  
208V , 20(90)A  
L-L  
660V , 20(90)A  
L-L  
400V , 20(90)A  
L-L  
208V , 20(90)A  
48VAC, 50-60Hz  
48VAC, 50-60Hz  
24VAC, 50-60Hz  
24VAC, 50-60Hz  
L-L  
660V , 20(90)A  
L-L  
400V , 20(90)A  
L-L  
208V , 20(90)A  
L-L  
660V , 20(90)A  
24VAC, 50-60Hz  
L-L  
400V , 5(10)A  
230VAC, 50-60Hz  
230VAC, 50-60Hz  
230VAC, 50-60Hz  
115VAC, 50-60Hz  
115VAC, 50-60Hz  
115VAC, 50-60Hz  
48VAC, 50-60Hz  
48VAC, 50-60Hz  
48VAC, 50-60Hz  
24VAC, 50-60Hz  
24VAC, 50-60Hz  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
L-L  
400V , 5(10)A  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
L-L  
400V , 5(10)A  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
L-L  
400V , 5(10)A  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
24VAC, 50-60Hz  
L-L  
100V , 5(10)A  
230VAC, 50-60Hz  
115VAC, 50-60Hz  
48VAC, 50-60Hz  
L-L  
100V , 5(10)A  
L-L  
100V , 5(10)A  
L-L  
100V , 5(10)A  
24VAC, 50-60Hz  
L-L  
400V , 20(90)A  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
18-60VDC [77-143VDC]  
AG2230 [AG2237]  
AG2231 [AG2238]  
AG2232 [AG2239]  
AG2233 [AG2240]  
AG2234 [AG2241]  
AG2235 [AG2242]  
AG2236 [AG2243]  
L-L  
208V , 20(90)A  
L-L  
660V , 20(90)A  
L-L  
400V , 5(10)A  
L-L  
208V , 5(10)A  
L-L  
660V , 5(10)A  
L-L  
100V , 5(10)A  
L-L  
Ava ila b le m o d u le s  
Type  
Channels  
Code  
Type  
Channels  
Code  
Open collector output  
Relay + open coll. output  
2
2
AO2900  
AO2910  
Digital inputs  
RS485 Serial Output  
2
1
AQ2940  
AR2950  
Possib le m od ule com b ina tions  
Power supply  
Basic unit  
Self p.s.  
Slot A Slot B Slot A Slot B  
Auxiliary p.s.  
Power supply  
Basic unit  
Self p.s.  
Slot A Slot B Slot A Slot B  
Auxiliary p.s.  
Digital inputs  
RS485 Serial Output  
(*) AV2 only  
Open collector output  
Relay + open coll. output  
(*)  
Specifications are subject to change without notice EM4-DINDS1003  
5
EM4-DIN  
W irin g d ia g ra m s  
20(90)A model: three-phase unbalanced load  
Self-power supply  
Fig. 3  
Auxiliary power supply  
Fig. 2  
Auxiliary power supply  
AC power supply  
Fig. 1  
AC power supply  
Direct connection (3-phase system + N)  
Direct connection (3-phase system)  
Direct connection (3-phase system w/out N )  
20(90)A model:  
5(10)A model:  
three-phase unbalanced load  
three-phase unbalanced load  
Self-power supply  
Fig. 4  
Auxiliary power supply  
Fig. 5  
Auxiliary power supply  
Fig. 6  
AC power supply  
AC power supply  
Direct connection (3-phase system  
with or without neutral)  
Direct connection (3-phase system + N)  
CT connection (3-phase system with neutral)  
5(10)A model: three-phase unbalanced load  
Auxiliary power supply  
Fig. 7  
Auxiliary power supply  
AC power supply  
Fig. 9  
Auxiliary power supply  
Fig. 8  
AC power supply  
AC power supply  
CT ARON connection (3-phase system)  
VT and CT ARON connection (3-phase system)  
VT and CT connection (3-phase system)  
6
Specifications are subject to change without notice EM4-DINDS1003  
EM4-DIN  
W iring d ia g ra m s (o p tio na l m o d ule s)  
Open collector output  
Fig.10  
Relay + open coll. output Fig. 11  
VDC max 30V  
Only open collector outputs: the grounds of the outputs are separated, and therefore its possible to carry out, for the same  
module, two different connections. The load resistance (Rc) must be designed so that the closed contact current is lower than  
100mA; the VDC voltage must be lower than or equal to 30V. VDC: power supply voltage output. Vo+: positive output contact  
(open collector transistor). GND: ground output contact (open collector transistor).  
Digital inputs  
Fig. 13  
RS485 Serial output  
Fig. 14  
Digital inputs  
Fig. 12  
PNP-NPN connections  
Contact and voltage connection  
2 and 4-wire connection  
Accura cy  
Accuracy (RDG) depending on the current  
Accuracy (RDG) depending on the current  
Error  
+4%  
Error  
+4%  
+1.5%  
+1%  
+2.5%  
+2%  
0%  
0%  
-1%  
-1.5%  
-2%  
-2.5%  
-4%  
PF=1  
-4%  
0,25A 0,5A  
1A 2A  
0.5A 1A  
2A 4A  
5A (Ib)  
20A (Ib)  
5A (Ib)  
20A (Ib)  
10A (Imax)  
90A (Imax)  
10A (Imax)  
90A (Imax)  
sinϕ=1  
sinϕ=0.5  
sinϕ=1  
0.1A 0.25A  
0.25A 0.5A  
1A 2A  
5A (Ib)  
5A (Ib)  
20A (Ib)  
20A (Ib)  
10A (Imax)  
10A (Imax)  
90A (Imax)  
90A (Imax)  
PF=L0.5  
or C0.8  
2A 4A  
EN 61036/ IEC 61036 limits (Active energy)  
5(10A) Start-up current: 20mA  
EN 61268/ IEC 61268 limits (Reactive energy)  
5(6A) Start-up current: 20mA  
20(90A) Start-up current: 80mA  
20(90A) Start-up current: 80mA  
Specifications are subject to change without notice EM4-DINDS1003  
7
EM4-DIN  
Fro nt p a ne l d e scrip tio n  
Keys for:  
- values programming;  
- function selection;  
- displaying the measuring pages.  
4
3
2. Display  
2
LCD with alphanumeric indications to:  
- display configuration parameters;  
- display all the measured variables.  
3. Removable label  
1
It shows the following information:  
- year of manufacturing  
- serial number  
- input voltages and currents  
- operating frequency  
- kWh measuring class  
1. Key-pad  
To program configuration parameters and to display variables.  
- kvarh measuring class  
- symbols: electric system, attention and dual insulation.  
4. Hidden dip-switch  
S-key to enter programming and confirm selections;  
Enable/disable the access to the programming procedure.  
Dim e nsio n s a n d p a ne l cut-o ut  
Te rm ina l b o a rd s  
Open collector dual  
output module  
Relay output + open  
coll. output module  
RS485  
Serial output module  
Digital inputs module  
AO 2900  
AO 2910  
AR 2950  
AQ 2940  
8
Specifications are subject to change without notice EM4-DINDS1003  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications