JZ1AF-9VTV [ETC]

;
JZ1AF-9VTV
型号: JZ1AF-9VTV
厂家: ETC    ETC
描述:

文件: 总5页 (文件大小:70K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
VDE  
SMALL SIZED  
POWER RELAY  
JZ-RELAYS  
14  
.551  
FEATURES  
22  
.866  
• Small sized flat type: 22×14×11.6 mm .866×.551×.457 inch  
• High dielectric withstanding: 10,000 V surge in µs between coil and contact  
• High electrical noise immunity  
11.6  
.457  
• High sensitivity type available  
• VDE,TÜV, SEMKO also approved  
mm inch  
SPECIFICATIONS  
Contact  
Characteristics  
(at 25°C 77°F, 50% Relative humidity)  
Standard  
type  
High  
Standard  
TV-5 High  
Max. operating speed  
Initial insulation resistance*1 Min. 100 Mat 500 V DC  
20 cpm  
Type  
sensitivity type TV-5 type sensitivity type  
Arrangement  
1 Form A  
Between open  
contacts  
750 Vrms for 1 min.  
2,000 Vrms for 1 min.  
Min. 10,000 V  
Initial  
Contact material  
Silver alloy  
breakdown  
Initial contact resistance, max.  
(By voltage drop 6 V DC 1 A)  
Between  
contacts and coil  
voltage*2  
100 mΩ  
5 A 125 V AC 3 A 125 V AC 8 A 125 V AC 8 A 125 V AC  
5 A 30 V DC 3 A 30 V DC 5 A 30 V DC 5 A 30 V DC  
Surge voltage between  
contact and coil*3  
Nominal switching capacity  
Rating  
(resistive)  
Max. switching power  
150 W, 750 VA 90 W, 500 VA 150 W, 1,250 VA 150 W, 1,000 VA  
Operate time*4  
(at nominal voltage)  
Release time*4  
(without diode)  
Approx. 4 ms  
Max. switching voltage  
250 V AC, 110 V DC (0.3 A)  
Max. switching current  
5 A  
105  
3 A  
8 A  
Approx. 2 ms  
Mechanical (at 180 cpm)  
Expected  
life (min.  
5 × 106  
(at nominal voltage)  
2 ×105  
105  
5 ×104  
Temperature rise  
(ambient temperature at  
70°C)  
Max. 45°C  
at max. switching current  
Electrical  
(at 20 cpm)  
(at nominal (3 A 125 V AC) (at nominal (8 A 125 V AC)  
operating  
capacity)  
105  
operating  
capacity)  
105  
operations)  
(3 A 30 V DC)  
(5 A 30 V DC)  
Functional*5  
Min. 98 m/s2 {10 G}  
Min. 980 m/s2 {100 G}  
98 m/s2 {10 G}, 10 to 55 Hz at  
double amplitude of 1.6 mm  
Shock  
Coil (at 20°C 68°F)  
Standard type  
Destructive*6  
Functional*7  
resistance  
Nominal operating power  
Nominal operating power  
400 mW  
200 mW  
High sensitivity type  
Vibration  
117.6 m/s2 {12 G}, 10 to 55 Hz  
at double amplitude of 2 mm  
resistance  
Remarks  
Destructive  
* Specifications will vary with foreign standards certification ratings.  
*1 Measurement at same location as "Initial breakdown voltage" section  
*2 Detection current: 10mA  
Conditions for operation, Ambient  
–40°C to +70°C  
–40°F to +158°F  
transport and storage*8  
(Not freezing and condens-  
ing at low temperature)  
temp.  
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981  
*4 Excluding contact bounce time  
Humidity  
5 to 85% R.H.  
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs  
*6 Half-wave pulse of sine wave: 6ms  
Unit weight  
Approx. 7 g .25 oz  
*7 Detection time: 10µs  
*8 Refer to 5. Conditions for operation, transport and storage mentioned in  
AMBIENT ENVIRONMENT (Page 24).  
TYPICAL APPLICATIONS ORDERING INFORMATION  
• Microwave oven (fan, inside lamp)  
Ex. JZ  
1a  
F
S
9 V  
TV  
• Machineries which need electrical  
noise resistance and surge resistance,  
(Ex. hot-water heater)  
Contact  
Protective  
arrangement construction  
Coil voltage  
(DC)  
Type classification  
Type classification  
1a: 1 Form A F: Flux-resistant Nil: Standard  
5, 6, 9, 12, Nil: UL/CSA/VDE  
type  
recognized type  
(400 mW)  
S: High sensitivity  
(200 mW)  
18, 24 V  
TV: TV-5 rated type  
Note: Standard packing Carton: 100 pcs. Case: 500 pcs.  
UL/CSA, TV-5 (only for TV type) approved type is standard.  
62  
JZ  
TYPES AND COIL DATA (at 20°C 68°F)  
1) Standard type  
Drop-out  
voltage,  
V DC (min.)  
Nominal  
operating  
current, mA  
Nominal  
operating  
power, mW  
Max. allowable  
voltage, at  
70°C, V DC  
Nominal voltage, Pick-up voltage,  
Coil resistance,  
Part No.  
V DC  
V DC (max.)  
(±10%)  
JZ1aF-5V  
JZ1aF-6V  
JZ1aF-9V  
JZ1aF-12V  
JZ1aF-18V  
JZ1aF-24V  
5
6
3.5  
4.2  
0.25  
0.3  
62.5  
90  
80  
67  
45  
33  
22  
17  
400  
400  
400  
400  
400  
400  
5.5  
6.6  
9
6.3  
0.45  
0.6  
202  
9.9  
12  
18  
24  
8.4  
360  
13.2  
19.8  
26.4  
12.6  
16.8  
0.9  
810  
1.2  
1,440  
2) High sensitivity type  
Drop-out  
voltage,  
V DC (min.)  
Nominal  
operating  
current, mA  
Nominal  
operating  
power, mW  
Max. allowable  
voltage, at  
70°C, V DC  
Nominal voltage, Pick-up voltage,  
Coil resistance,  
Part No.  
V DC  
V DC (max.)  
(±10%)  
JZ1aFS-5V  
JZ1aFS-6V  
JZ1aFS-9V  
JZ1aFS-12V  
JZ1aFS-18V  
JZ1aFS-24V  
5
6
4
0.25  
0.3  
125  
180  
40  
33  
22  
17  
11  
8.3  
200  
200  
200  
200  
200  
200  
6.5  
7.8  
4.8  
7.2  
9.6  
14.4  
19.2  
9
0.45  
0.6  
405  
11.7  
15.6  
23.4  
31.2  
12  
18  
24  
720  
0.9  
1,620  
2,880  
1.2  
mm inch  
DIMENSIONS  
PC board pattern (Copper-side view)  
22  
14  
.866  
.551  
2-1.3 dia.  
2-.051 dia.  
2-0.9 dia.  
2-.035 dia.  
15.24  
.600  
11.2  
.441  
4.3  
7.62  
.300  
10.16  
.400  
.169  
0.4  
.016  
2.54  
17.78  
.700  
.100  
15.24  
.600  
5.08  
.200  
Tolerance: ±0.1±.004  
COM  
3
4
2
1
7.62  
.300  
10.16  
.400  
N.O.  
2.11  
.083  
General tolerance: ±0.3 ± .012  
REFERENCE DATA  
• Not TV-5 rated type  
1. Max. switching power  
(AC resistive load)  
2.-(1) Operate/Release time  
(Standard type)  
2.-(2) Operate/Release time  
(High sensitivity type)  
100  
10  
10  
8
8
Standard type  
10  
6
6
5
Operate time  
Operate time  
4
4
High sensitivity type  
1
Max.  
Max.  
x
Max.  
Max.  
– –  
Min.  
x x  
Min.  
x
Min.  
2
2
Min.  
Release time  
Release time  
0
0
10  
100 250 1,000  
AC voltage, V  
80  
100  
120  
80  
100  
120  
Coil applied voltage, %V  
Coil applied voltage, %V  
63  
JZ  
3. Coil temperature rise  
4.-(1) Ambient temperature vs. coil applied  
voltage (Standard type)  
Contact current: 1 A  
4.-(2) Ambient temperature vs. coil applied  
voltage (High sensitivity type)  
Contact current: 1 A  
Point measured: Coil inside  
Contact current: 3 A  
500  
Allowable ambient temperature  
against % coil voltages  
(max. inside the coil  
temperature set as  
115°C 239°F)  
160  
140  
120  
100  
80  
30°C  
(Standard type)  
400  
80  
60  
Allowable ambient temperature  
against % coil voltages  
30°C  
(High sensitivity type)  
300  
200  
100  
0
(max. inside the coil temperature  
70°C  
set as 115°C 239°F)  
(Standard  
type)  
40  
20  
0
70°C  
(High sensitivity  
type)  
Pick-up voltage  
60  
Pick-up voltage  
0
20  
40  
60  
80  
20  
40  
60  
80  
70 80 100 120 140 160 180  
Coil applied voltage, %V  
Ambient temperature, °C  
Ambient temperature, °C  
5. Electrical life (load test: fan motor, turntable motor and inside lamp of microwave oven)  
Tested sample: JZ1aFS-24V, 6 pcs.  
Load: 100 V AC 0.5 A; Rush current: 2.5 A  
Operation frequency: 4 times/min.  
(ON:OFF = 3s:12s)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
With coil diode protection  
Ambient temperature: 70°C 158°F  
80  
60  
40  
20  
0
80  
Circuit  
Pick-up voltage  
60  
Max.  
x
30 W  
Min.  
Max.  
motor  
(fan  
motor)  
100 V  
AC  
20 W  
lamp  
(Inside lamp)  
3 W  
40  
20  
0
x
M
M
motor  
(turntable  
motor)  
Min.  
Drop-out voltage  
Max.  
x
Min.  
5
10  
15  
20  
5
10  
15  
20  
No. of operations, ×104  
No. of operations, ×104  
6. Noise resistance  
Noise wave form  
Output wave form  
Tested sample: JZ1aFS-24V  
(Applied voltage wave form to the contact)  
(Output wave form on the coil side)  
10,000  
9,500  
50  
Circuit  
Surge  
simulator  
Digital  
memory  
8,000  
6,000  
4,000  
2,000  
40  
30  
20  
10  
Contact  
Coil  
70Ω  
0
1
2
3
4
0
1
2
3
4
Time, µs  
Time, µs  
• TV-5 rated type  
1. Max. switching power  
2-(1). Operate/Release time  
(Standard type)  
2-(2). Operate/Release time  
(High sensitivity type)  
Sample: JZ1aF-12V-TV  
Sample: JZ1aFS-12V-TV  
8
10  
100  
8
6
AC resistive load  
10  
1
6
4
4
2
0
Max.  
Operate time  
x
Max.  
Max.  
Min.  
x
Min.  
x
2
0
Min.  
Release time  
10  
100 250  
1,000  
80  
100  
120 130  
80  
100 120 140 160 180  
Coil applied voltage, %V  
Contact voltage, V  
Coil applied voltage, %V  
64  
JZ  
3-(1). Coil temperature rise (Standard type)  
3-(2). Coil temperature rise (High sensitivity type)  
Sample: JZ1aF-12V-TV  
Point measured: Coil inside  
Contact current: 8 A  
Sample: JZ1aFS-12V-TV  
Point measured: Coil inside  
Contact current: 5 A  
80  
100  
80  
60  
30°C  
60  
30°C  
40  
20  
0
70°C  
70°C  
40  
20  
0
80 90 100 110 120 130  
Coil applied voltage, %V  
80 100 120 140 160 180  
Coil applied voltage, %V  
4-(1). Ambient temperature vs. coil applied  
voltage (Standard type)  
4-(2). Ambient temperature vs. coil applied  
voltage (High sensitivity type)  
Sample: JZ1aF-12V-TV  
Sample: JZ1aFS-12V-TV  
Contact current: 5 A  
500  
180  
160  
0 A  
400  
Allowable ambient  
temperature against  
% coil voltage  
5 A  
Allowable ambient  
300  
140  
(max. inside the coil  
temperature against  
temterature set as  
115°C 239°F)  
% coil voltage  
120  
100  
80  
(max. inside the coil  
temterature set as  
115°C 239°F)  
200  
100  
0
Pick-up voltage  
with a hot-start  
condition of 100%V  
Pick-up voltage  
with a hot-start  
condition of 100%V  
5 A  
0 A  
Pick-up voltage  
Pick-up voltage  
60  
0
20  
40  
60  
80  
20  
40  
60  
80  
Ambient temperature, °C  
Ambient temperature, °C  
5-(1). Electrical life test (TV-5)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Tested sample: JZ1aF-12V-TV, 6 pcs.  
UL Lamp load test  
50  
80  
Pick-up voltage  
Max.  
Overload  
Endurance  
AC 120 V  
x
40  
30  
20  
10  
0
Min.  
Voltage  
AC 120 V  
60  
40  
Switching  
frequency  
60 Hz  
60 Hz  
Inrush: 111 A; Inrush: 78 A;  
Steady: 7.5 A Steady: 5.0 A  
Current  
Drop-out voltage  
Max.  
10 cpm  
(ON:OFF =  
1s:5s)  
10 cpm  
(ON:OFF =  
1s:5s)  
x
20  
0
Max.  
Operating  
speed  
x
Min.  
Min.  
No. of  
operations  
50 ope.  
25,000 ope.  
2.5  
No. of operations  
2.5  
No. of operations  
5-(2). Electrical life test (Condenser load)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Tested sample: JZ1aF-12V-TV, 6 pcs.  
Load: DC 17 V 6.4 A, Inrush max. 139 A  
Operating speed: 20 cpm  
80  
50  
40  
30  
20  
10  
0
(ON:OFF = 1 s:2 s)  
Pick-up voltage  
Max.  
Ambient temperature: 27°C 81°F  
60  
40  
x
Circuit:  
Min.  
Changing coil  
12 m200 µH  
Mis-contacting  
DC  
17 V  
detection  
Contact welding  
detection  
20  
0
16000  
µH  
Drop-out voltage  
2.7 Ω  
Max.  
Max.  
x
x
Min.  
Min.  
10  
No. of operations, ×104  
10  
No. of operations  
65  
JZ  
5-(3). Electrical life test (TV power source)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Tested sample: JZ1aF-12V-TV, 10 pcs.  
Load: AC 100 V TV power source  
Inrush: 100 A max.; Steady: 5.0 A  
Operating speed: 20 cpm  
(ON:OFF = 1 s:2 s)  
Ambient temperature: 40°C 104°F95% R.H.  
80  
50  
Pick-up voltage  
40  
30  
20  
10  
0
Max.  
60  
40  
x
Circuit:  
Min.  
Mis-contacting  
20  
0
PC  
board  
Drop-out voltage  
AC  
100 V  
detection  
Max.  
Max.  
x
Contact welding  
detection  
x
Min.  
Min.  
40°C 95%R.H.  
10  
No. of operations, ×104  
10  
No. of operations, ×104  
For Cautions for Use, see Relay Technical Information (Page 11 to 39).  
66