PM-F24P [ETC]
Ultra-small U-shaped Micro Photoelectric Sensor;型号: | PM-F24P |
厂家: | ETC |
描述: | Ultra-small U-shaped Micro Photoelectric Sensor 传感器 换能器 |
文件: | 总6页 (文件大小:483K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Amplifier Built-in
PUltrMa-sm-a2ll U4-shaped Micro Photoelectric Sensor
Korea’s S-mark.............................. P.1410
SERIES
451
■General terms and conditions ........... F-17
■
■Sensor selection guide.................. P.441~
FIBER
SENSORS
Related Information
Glossary of terms / General precautions.......P.1359~ / P.1405
■
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
Recognition
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Certified
(Some models only)
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic-electric-works.net/sunx
STATIC CONTROL
DEVICES
ENDOSCOPE
Extremely small size enables space saving!!
LASER
MARKERS
PLC /
TERMINALS
Extremely small size and space saving
Equipped with two independent outputs
HUMAN MACHINE
INTERFACES
PM-24 series contributes to the miniaturization or space
saving of your equipment.
All models are equipped with two independent outputs-
Light-ON and Dark-ON.
ENERGY CONSUMPTION
VISUALIZATION
Hence, one model suffices even if the output is to be
used differently, depending upon the location of use.
Also, since two independent outputs have been
provided, cumbersome handling of the output conversion
control input, or fear of logic inversion due to a cable
break, is eliminated. The sensor can be connected to the
existing wiring as it is.
COMPONENTS
Previous
model
Ultra-small type
FA COMPONENTS
PM-K24(-R)
25.4 mm
1.000 in
MACHINE VISION
SYSTEMS
22 mm
UV CURING
SYSTEMS
0.866 in
22.3
mm
0.878 in
Example of connection with a commercial intermediate connector
12 mm
0.472 in
Commercial intermediate connector
+V
0 V
11 mm
Selection
Guide
(
)
0.433 in
Output 1 (Light-ON)
Output 2 (Dark-ON)
U-shaped
To PLC
Convergent
Reflective
Just connect the cable of the used
output (either Light-ON or Dark-ON).
Connected device side
can be left as it is.
PM-64
PM-24
Note: Ensure to insulate the unused output wire.
PM-44/PM-54
Wide model variety
Meets global requirements
A wide variety of 5 shapes and 15 models is available.
You may select from this wide range to suit the mounting
conditions.
Conforms to Europe’s EMC Directive and obtains UL
Recognition.
Both, NPN and PNP output models are available.
The PM-□24 has also obtained Korea’s S-mark
certification.
Ultra-small U-shaped Micro Photoelectric Sensor PM-24SERIES
452
APPLICATIONS
FIBER
SENSORS
LASER
Sensing the starting point on a
rotating body
SENSORS
PHOTO-
ELECTRIC
SENSORS
The starting point can be sensed by
making a slit in the rotating body.
MICRO
PHOTO-
ELECTRIC
SENSORS
Starting point
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
ORDER GUIDE
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Type
Appearance (mm in)
Sensing range
Model No. (Note)
Output
Output operation
WIRE-SAVING
SYSTEMS
NPN open-collector
transistor
PM-K24
MEASURE-
MENT
PNP open-collector
transistor
SENSORS
PM-K24P
PM-K24-R
PM-L24
6 0.236
22
12
STATIC
0.866
0.472
CONTROL
DEVICES
NPN open-collector
transistor
NPN open-collector
transistor
ENDOSCOPE
LASER
PNP open-collector
transistor
12 0.472
MARKERS
PM-L24P
PM-L24-R
PM-F24
10.5
13.4
NPN open-collector
transistor
PLC /
0.413
0.528
TERMINALS
HUMAN
NPN open-collector
transistor
MACHINE
INTERFACES
5 mm 0.197 in
(fixed)
ENERGY
10.5 0.413
PNP open-collector
transistor
Incorporated with 2 outputs:
Light-ON / Dark-ON
CONSUMPTION
VISUALIZATION
COMPONENTS
PM-F24P
PM-F24-R
PM-R24
12
13.4
0.472
0.528
NPN open-collector
transistor
FA
COMPONENTS
NPN open-collector
transistor
MACHINE
VISION
10.5 0.413
SYSTEMS
PNP open-collector
transistor
PM-R24P
PM-R24-R
PM-U24
UV
CURING
SYSTEMS
12
13.4
0.472
0.528
NPN open-collector
transistor
NPN open-collector
transistor
Selection
Guide
PNP open-collector
transistor
6 0.236
PM-U24P
PM-U24-R
16
U-shaped
13.4
0.630
0.528
NPN open-collector
transistor
Convergent
Reflective
Note: The suffix “-R” indicates a flexible cable type.
PM-64
PM-24
3 m 9.843 ft cable length type
PM-44/
PM-54
3 m 9.843 ft cable length type (standard: 1 m 3.281 ft) is also available. (excluding flexible cable type and PNP output type)
When ordering this type, suffix “-C3” to the model No.
(e.g.) 3m 9.843 ft cable length type of PM-K24 is “PM-K24-C3”.
OPTIONS
Mounting screw
Designation
Model No.
Description
•ꢀMS-M2
Mounting screw with washers for the ultra-small type sensor
(50 pcs. lot). It can mount securely as it is spring washer
attached.
Mounting screw
MS-M2
Ultra-small U-shaped Micro Photoelectric Sensor PM-24SERIES
453
FIBER
SPECIFICATIONS
SENSORS
LASER
SENSORS
Ultra-small
Type
PHOTO-
ELECTRIC
SENSORS
With flexible cable
NPN output
PNP output
PM-□24
PM-□24-R
MICRO
PHOTO-
ELECTRIC
SENSORS
Item
PM-□24P
AREA
Sensing range
5 mm 0.197 in (fixed)
0.8 × 1.8 mm 0.031 × 0.071 in opaque object
0.05 mm 0.002 in or less
SENSORS
Minimum sensing object
Hysteresis
LIGHT
CURTAINS
PRESSURE /
FLOW
Repeatability
0.03 mm 0.001 in or less
SENSORS
Supply voltage
5 to 24 V DC ±10 % Ripple P-P 10 % or less
15 mA or less
INDUCTIVE
PROXIMITY
SENSORS
Current consumption
PARTICULAR
USE
<NPN output type>
NPN open-collector transistor
<PNP output type>
PNP open-collector transistor
SENSORS
• Maximum sink current: 50 mA
• Maximum source current: 50 mA
SENSOR
OPTIONS
Output
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 0.7 V or less (at 50 mA sink current)
0.4 V or less (at 16 mA sink current)
• Applied voltage: 30 V DC or less (between output and + V)
• Residual voltage: 0.7 V or less (at 50 mA source current)
0.4 V or less (at 16 mA source current)
SIMPLE
WIRE-SAVING
UNITS
Utilization category
Output operation
DC-12 or DC-13
WIRE-SAVING
SYSTEMS
Incorporated with 2 outputs: Light-ON / Dark-ON
MEASURE-
MENT
SENSORS
Under light received condition: 20 µs or less
Under light interrupted condition: 100 µs or less
(Response frequency: 1 kHz or more) (Note 2)
Response time
STATIC
CONTROL
DEVICES
Operation indicator
Pollution degree
Ambient temperature (Note 3, 4)
Ambient humidity
Ambient illuminance
EMC
Vermilion LED (lights up under light received condition)
3 (Industrial environment)
ENDOSCOPE
LASER
–25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +80 °C –22 to +176 °F
35 to 85 % RH, Storage: 35 to 85 % RH
MARKERS
PLC /
TERMINALS
Fluorescent light: 1,000 ℓx at the light-receiving face
HUMAN
MACHINE
EN 60947-5-2
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Emitting element
Material
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 2,000 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 940 nm 0.037 mil, non-modulated)
Enclosure: PBT, Slit cover: Polycarbonate
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Cable
0.09 mm2 4-core cabtyre cable [PM-□24-R: 0.1 mm2 flexible, oil and heat resistant cabtyre cable (Note 5)], 1 m 3.281 ft long
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 10 g approx.
Cable extension
Weight
Selection
Guide
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
U-shaped
2) The response frequency is the value when the disc, given in the figure below, is rotated.
Convergent
Reflective
1.8 mm 0.071 in
Disc
PM-64
PM-24
Disc
PM-44/
PM-54
t = 0.2 mm 0.008 in
1.6 mm 0.063 in
1.6 mm 0.063 in
3) In case the PM-24 series is used at an ambient temperature of +50 °C +122 °F, or more, make sure to mount it on a metal body.
4) Take care that the flexibility of the PM-□24-R cable is lost if the ambient temperature in –10 °C +14 °F or less.
5) The cable of PM-□24-R is a flexible cable usable on a moving base. When the sensor is mounted on a moving base, fix the sensor cable joint so that
stress is not applied to it. (Models other than the PM-□24-R cannot be used on a moving base.)
Ultra-small U-shaped Micro Photoelectric Sensor PM-24SERIES
454
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
LASER
SENSORS
NPN output type
PM-□24 PM-□24-R
PHOTO-
I/O circuit diagram
Wiring diagram
ELECTRIC
SENSORS
MICRO
Color code
Brown
Black
White
Blue
PHOTO-
ELECTRIC
SENSORS
(Brown) +V
Load
ZD±
(Black) Output ±
Load
Load
AREA
+
–
SENSORS
(Note ±,2)
5 to 24 V DC
±±1 %
Load
+
–
5 to 24 V DC
±±1 %
51 mA max.
Tr±
LIGHT
(White) Output 2 (Note ±,2)
ZD2
Tr2
CURTAINS
51 mA max.
(Blue) 1 V
PRESSURE /
FLOW
SENSORS
Internal circuit
Users’ circuit
INDUCTIVE
PROXIMITY
SENSORS
Output operation
Notes: 1) Make sure to connect terminals correctly as the sensor does not
incorporate a reverse polarity protection circuit.
Color code
Black
Output operation
Light-ON
PARTICULAR
USE
Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a
capacitive load. Faulty wiring may result in damage.
2) Ensure to insulate the unused output wire.
Output 1
Output 2
SENSORS
White
Dark-ON
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Symbols … ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2 : NPN output transistor
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
PNP output type
PM-□24P
SENSORS
I/O circuit diagram
Wiring diagram
STATIC
CONTROL
DEVICES
Color code
(Brown) +V
Brown
ENDOSCOPE
Black
White
Blue
ZD±
51 mA max.
+
LASER
5 to 24 V DC
Tr±
ZD2
MARKERS
+
±±1 %
–
5 to 24 V DC
±±1 %
(Black) Output ± (Note ±,2)
51 mA max.
Load
–
Load
Tr2
PLC /
Load
(White) Output 2 (Note ±,2)
Load
TERMINALS
(Blue) 1 V
HUMAN
MACHINE
INTERFACES
Internal circuit
Users’ circuit
Output operation
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Notes: 1) Make sure to connect terminals correctly as the sensor does not
incorporate a reverse polarity protection circuit.
Color code
Black
Output operation
Light-ON
Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a
capacitive load. Faulty wiring may result in damage.
2) Ensure to insulate the unused output wire.
FA
Output 1
Output 2
COMPONENTS
White
Dark-ON
MACHINE
VISION
SYSTEMS
UV
Symbols … ZD1, ZD2 : Surge absorption zener diode
Tr1, Tr2 : PNP output transistor
CURING
SYSTEMS
SENSING CHARACTERISTICS (TYPICAL)
Selection
Guide
U-shaped
Sensing position
Convergent
Reflective
Dark-
ON
Dark-
ON
5.5 mm
0.217 in
PM-64
PM-24
ℓ
6 mm
PM-44/
PM-54
0.236 in
ℓ
2 mm
0.079 in
Beam
axis
Light-
ON
Light-
ON
0
0
1
2
3
4
1
2
3
4
0.039
0.079
0.118
0.157
0.039
0.079
0.118
0.157
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Ultra-small U-shaped Micro Photoelectric Sensor PM-24SERIES
455
FIBER
PRECAUTIONS FOR PROPER USE
Refer to General precautions.
SENSORS
LASER
SENSORS
Cable extension
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
• Cable extension is possible up to an overall length of
PHOTO-
ELECTRIC
SENSORS
100 m 328.084 ft with a 0.3 mm2, or more, cable.
However, since a voltage drop shall occur due to the cable
extension, ensure that the power supply voltage at the end
of the cable attached to the sensor is within the rating.
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
Total cable length ±11 m 328.184 ft
LIGHT
CURTAINS
Cable attached
to sensor
+V
Extension cable
PRESSURE /
FLOW
+
–
Output
5 to 24 V DC
±±1 %
Make sure to connect terminals correctly as
the sensor does not incorporate a reverse
polarity protection circuit.
SENSORS
1 V
INDUCTIVE
PROXIMITY
SENSORS
Further, the output is not incorporated with a
short-circuit protection circuit. Do not connect
it directly to a power supply or a capacitive
load. Faulty wiring may result in damage.
Supply voltage: 4.5 V or more
PARTICULAR
USE
But, when the overall cable length, including the cable
attached to the sensor, is as given below, there is no
need to confirm the voltage.
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Conductor cross-
section area of
extension cable
Mounting
Total cable length
• When fixing the sensor with screws, use M2 screws and
the tightening torque should be 0.15 N·m or less.
Further, use small, round type plain washers. (ø4.3 mm
ø0.169 in)
When using the optional mounting screw set MS-M2, a
spring washer is included.
WIRE-SAVING
SYSTEMS
0.08 to 0.1 mm2
Up to 5 m 16.404 ft
Up to 10 m 32.808 ft
Up to 20 m 65.617 ft
MEASURE-
MENT
0.2 mm2
SENSORS
0.3 mm2
STATIC
CONTROL
DEVICES
M2 screws
Others
ENDOSCOPE
• Since the sensor is intended for
use inside machines, no special
countermeasures have been taken
against extraneous light. Take care
that extraneous light is not directly
incident on the beam receiving section.
Spring washer
LASER
MARKERS
Plain washer
Outer diameter
ø4.3 mm
PLC /
TERMINALS
ø0.169 in
HUMAN
MACHINE
INTERFACES
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
• In case the PM-24 series is used at an ambient
temperature of +50 °C +122 °F, or more, make sure to
mount it on a metal body.
• The cable of PM-□24-R is a flexible cable usable on a
moving base. When the sensor is mounted on a moving
base, fix the sensor cable joint so that stress is not
applied to it. (Models other than the PM-□24-R cannot be
used on a moving base.)
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
• Take care that the flexibility of the PM-□24-R cable is lost
if the ambient temperature is –10 °C +14 °F or less.
SYSTEMS
Selection
Guide
U-shaped
Convergent
Reflective
PM-64
PM-24
PM-44/
PM-54
Ultra-small U-shaped Micro Photoelectric Sensor PM-24SERIES
456
DIMENSIONS (Unit: mm in)
FIBER
The CAD data in the dimensions can be downloaded from our website.
SENSORS
LASER
SENSORS
Sensor
Sensor
PM-K24(P) PM-K24-R
PM-L24(P) PM-L24-R
PHOTO-
3
3
ELECTRIC
SENSORS
0.118
0.118
MICRO
PHOTO-
ELECTRIC
SENSORS
6
Beam axis
Beam axis
0.236
10.5
5.5 0.217
0.413
AREA
SENSORS
13.4
ø2.7 ø0.106 cable, 1 m 3.281 ft long
0.528
2
5.5
0.5197
8
LIGHT
0.079
0.217
CURTAINS
0.315
2-ø2.5 ø0.098 mounting holes
Beam axis
PRESSURE /
FLOW
12
8
13.4
0.528
0.5197
0.472
0.315
SENSORS
6
4 0.157
0.236
INDUCTIVE
PROXIMITY
SENSORS
2-ø2.5 ø0.098
mounting holes
Operation indicator
(Vermilion)
ø2.7 ø0.106 cable,
1 m 3.281 ft long
2
Beam axis
5.5 0.217
0.079
PARTICULAR
USE
12
10 0.394
0.472
ø4.8
SENSORS
4 0.157
ø0.189
Operation indicator
(Vermilion)
18 0.709
22 0.866
SENSOR
OPTIONS
2
0.079
SIMPLE
WIRE-SAVING
UNITS
Sensor
Sensor
PM-F24(P) PM-F24-R
PM-R24(P) PM-R24-R
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
Beam axis
Beam axis
SENSORS
STATIC
4
4
CONTROL
DEVICES
0.157
0.157
6.7
6.7
0.264
0.264
ENDOSCOPE
10.5
0.413
10.5
LASER
13.4
0.413
6
1.5 0.059
6
MARKERS
0.528
0.5197
13.4
1.5 0.059
2
0.236
0.528
5.5
0.217
3
5.5
2
0.236
0.5197
5.5
3
0.118
0.217
0.079
0.079
PLC /
0.217
0.118
TERMINALS
Beam axis
Beam axis
5.5 0.217
8
8
12
12
HUMAN
0.315
0.315
0.472
0.472
MACHINE
INTERFACES
4 0.157
4 0.157
Operation indicator
(Vermilion)
ENERGY
ø2
Operation indicator
(Vermilion)
CONSUMPTION
VISUALIZATION
COMPONENTS
ø2
ø0.079
2
2
ø0.079
ø2.7 ø0.106 cable,
1 m 3.281 ft long
0.079
0.079
ø4.8
ø0.189
ø2.5 ø0.098 mounting hole
ø4.8
ø2.5 ø0.098 mounting hole
FA
ø0.189
COMPONENTS
ø2.7 ø0.106 cable, 1 m 3.281 ft long
MACHINE
VISION
SYSTEMS
UV
Sensor
PM-U24(P) PM-U24-R
CURING
SYSTEMS
3
0.118
6
Beam axis
0.236
Selection
Guide
U-shaped
Convergent
Reflective
13.4
0.528
2
0.5197
0.079
PM-64
PM-24
Beam axis
5.5 0.217
16
12
PM-44/
PM-54
0.630
0.472
Operation indicator
(Vermilion)
8
ø2.7 ø0.106 cable, 1 m 3.281 ft long
0.315
2-ø2.5 ø0.098 mounting holes
相关型号:
©2020 ICPDF网 联系我们和版权申明