PM-F64P [ETC]
Connector Built-in U-shaped Micro Photoelectric Sensor;型号: | PM-F64P |
厂家: | ETC |
描述: | Connector Built-in U-shaped Micro Photoelectric Sensor |
文件: | 总8页 (文件大小:705K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Amplifier Built-in
PConMnecto-r6Bu4ilt-in U-shaped Micro Photoelectric Sensor
SERIES
443
■General terms and conditions ........... F-17
■Sensor selection guide.................. P.441~
■General precautions ..................... P.1405
FIBER
SENSORS
Related Information
■Glossary of terms........................ P.1359~
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
Recognition
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic-electric-works.net/sunx
STATIC CONTROL
DEVICES
Easy connection with a single touch
ENDOSCOPE
using commercially-available connectors
LASER
MARKERS
PLC /
TERMINALS
Built-in connector saves space
Can be connected using commercially-
available connectors
HUMAN MACHINE
INTERFACES
This greatly reduces the amount of space taken up
compared to previous models.
The dimension between the beam axis and cable
bending part has been reduced to half at maximum.
The connector connection type eliminates the extra
work of soldering and insulation processing. In addition,
the connector used is a commercially-available multi-
purpose connector which is also currently used by the
DP-100 series of digital pressure sensors.
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
Previous model
PM-□64
Connector type
UV CURING
SYSTEMS
26 mm
25.4 mm
1.000 in
1.024 in
22.3 mm
0.878 in
23 mm
0.906 in
Selection
Guide
U-shaped
11 mm
App6ro0xim%ately
of previous
model
0.433 in
Convergent
Reflective
2.1 mm
0.083 in
Detachable
PM-64
PM-24
Commercially-
available connector
Digital pressure sensor
PM-44/PM-54
DP-100 series
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64SERIES
444
APPLICATIONS
FIBER
SENSORS
LASER
Determining the pallet position
Sensing the starting point and
Sensing the starting point
on a rotating body
SENSORS
overrun of a moving body
Overrun sensing
Dog
PHOTOELECTRIC
SENSORS
Starting
point
MICRO
PHOTOELECTRIC
SENSORS
The starting
point can be
sensed by
making a slit in
the rotating
body.
AREA
SENSORS
Starting point sensing
LIGHT
CURTAINS
Overrun
sensing
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Starting point and overrun is
sensed using the dog on the base.
Pallet is stopped by sensing the dog.
PARTICULAR
USE SENSORS
Improved maintenance and workability significantly reduces total cost
SENSOR
OPTIONS
The processing cost of the connector cables can be drastically reduced through the use of commercially-available
crimping connectors.
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Previous model (Soldering: Connector type)
• Automation is hard because of soldering.
• Insulation processing is required.
• A large space is necessary at the terminal area.
Insulation processing
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
• Connectors are not reliable
(not fully connected or seated).
Soldering
ENDOSCOPE
Previous model (Converted to the cable-type commercially-available connector)
• Crimping processing is required in two places.
LASER
MARKERS
• A set of commercially-available connectors is
Intermediate box
Commercially-available connector
necessary.
PLC /
TERMINALS
•
There are many processes for cable connections.
• An intermediate box is required.
HUMAN MACHINE
INTERFACES
Crimping processing
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
Suggestion
FA COMPONENTS
• Crimping processing makes automation
possible so the connectors are also highly
reliable.
PM-64 series (Commercially-available connectors can be used)
MACHINE VISION
SYSTEMS
Crimping processing
• Soldering, insulation processing, and an
UV CURING
SYSTEMS
intermediate box are not necessary.
• Connectors are widely available.
• Mounting in a small space is easy.
• Strongly connected using a locking connector.
Selection
Guide
• 1 m 3.281 ft, 2 m 6.562 ft, 3 m 9.843 ft, and 5 m
16.404 ft connector cables are available.
U-shaped
Convergent
Reflective
PM-64
PM-24
PM-44/PM-54
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64SERIES
445
FIBER
ORDER GUIDE
SENSORS
LASER
SENSORS
Type
Appearance (mm in)
Sensing range
Model No.
PM-K64
Output
Output operation
PHOTO-
ELECTRIC
SENSORS
NPN open-collector
transistor
MICRO
PHOTO-
ELECTRIC
SENSORS
7
0.207 in
23
26 1.024 in
PNP open-collector
transistor
AREA
PM-K64P
PM-T64
0.906 in
SENSORS
LIGHT
CURTAINS
NPN open-collector
transistor
13.7 0.539 in
PRESSURE /
FLOW
SENSORS
PNP open-collector
transistor
23
26 1.024 in
PM-T64P
INDUCTIVE
PROXIMITY
SENSORS
0.906 in
PARTICULAR
USE
SENSORS
16.7 0.657 in
PM-T64W
(Note)
NPN open-collector
transistor
SENSOR
OPTIONS
26 1.024 in
23
0.906 in
SIMPLE
WIRE-SAVING
UNITS
NPN open-collector
transistor
PM-L64
WIRE-SAVING
SYSTEMS
5 mm 0.197 in
Incorporated with 2 outputs:
Light-ON / Dark-ON
15.5 0.610 in
15.7 0.618 in
(fixed)
MEASURE-
MENT
PNP open-collector
transistor
26.2 1.031 in
PM-L64P
PM-Y64
PM-Y64P
PM-F64
SENSORS
STATIC
CONTROL
DEVICES
NPN open-collector
transistor
15.5 0.610 in
ENDOSCOPE
22.7
PNP open-collector
transistor
13.8 0.543 in
0.894 in
LASER
MARKERS
NPN open-collector
transistor
PLC /
TERMINALS
14 0.551 in
HUMAN
MACHINE
23
PNP open-collector
transistor
INTERFACES
0.906 in
13.4 0.528 in
PM-F64P
PM-R64
PM-R64P
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
NPN open-collector
transistor
14 0.551 in
FA
COMPONENTS
23
MACHINE
VISION
PNP open-collector
transistor
13.4 0.528 in
0.906 in
SYSTEMS
UV
CURING
Note: PM-T64W is compatible with our conventional PM-T53(B).
SYSTEMS
OPTIONS
Connector attached cable
Selection
Guide
Designation
Model No.
Description
• CN-14A(-R)-C□
U-shaped
Convergent
Length: 1m 3.281 ft
Length: 2m 6.562 ft
Length: 3m 9.843 ft
Length: 5m 16.404 ft
Length: 1m 3.281 ft
Length: 2m 6.562 ft
Length: 3m 9.843 ft
Length: 5m 16.404 ft
CN-14A-C1
CN-14A-C2
CN-14A-C3
CN-14A-C5
CN-14A-R-C1
CN-14A-R-C2
CN-14A-R-C3
CN-14A-R-C5
CN-14A
Reflective
Connector
attached
cable
PM-64
PM-24
0.2 mm2 4-core cabtyre cable with
connector on one end
Cable outer diameter: ø3.7mm
ø0.146 in
PM-44/
PM-54
Connector
attached
cable
Flexible
cable
Connector
• CN-14A
Contact
Connector
Set of 10 housings and 40 contacts
4
Recommended connector
Housing
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Recommended crimping tool
Model No. : YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64SERIES
446
SPECIFICATIONS
FIBER
SENSORS
LASER
SENSORS
Small and built-in connector type
Type
PHOTO-
K type
PM-K64
PM-K64P
T type
L type
PM-L64
PM-L64P
Y type
PM-Y64
PM-Y64P
F type
PM-F64
PM-F64P
R type
PM-R64
PM-R64P
ELECTRIC
SENSORS
NPN output
PM-T64(W)
PM-T64P
MICRO
PHOTO-
ELECTRIC
SENSORS
Item
PNP output
AREA
Sensing range
5 mm 0.197 in (fixed)
SENSORS
Minimum sensing object
Hysteresis
0.8 × 1.8 mm 0.031 × 0.071 in opaque object
0.05 mm 0.002 in or less (Note 2)
0.01 mm 0.0004 in or less (Note 3)
5 to 24 V DC ±10 % Ripple P-P 10 % or less
15 mA or less
LIGHT
CURTAINS
PRESSURE /
FLOW
Repeatability
SENSORS
Supply voltage
INDUCTIVE
PROXIMITY
SENSORS
Current consumption
PARTICULAR
USE
<NPN output type>
NPN open-collector transistor
<PNP output type>
PNP open-collector transistor
• Maximum source current: 50 mA
SENSORS
• Maximum sink current: 50 mA
SENSOR
OPTIONS
Output
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 0.7 V or less (at 50 mA sink current)
0.4 V or less (at 16 mA sink current)
• Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 0.7 V or less (at 50 mA source current)
0.4 V or less (at 16 mA source current)
SIMPLE
WIRE-SAVING
UNITS
Utilization category
Output operation
DC-12 or DC-13
WIRE-SAVING
SYSTEMS
Incorporated with 2 outputs: Light-ON / Dark-ON
MEASURE-
MENT
Under light received condition: 20 µs or less
Under light interrupted condition: 100 µs or less
(Response frequency: 1 kHz or more) (Note 4)
SENSORS
Response time
STATIC
CONTROL
DEVICES
Operation indicator
Pollution degree
Ambient temperature
Ambient humidity
Ambient illuminance
EMC
Orange LED (lights up under light received condition)
3 (Industrial environment)
ENDOSCOPE
LASER
–25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +80 °C –22 to +176 °F
35 to 85 % RH, Storage: 5 to 95 % RH (Note 5)
MARKERS
PLC /
TERMINALS
Fluorescent light: 1,000 ℓx at the light-receiving face
HUMAN
MACHINE
INTERFACES
EN 60947-5-2
ENERGY
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Emitting element
Material
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 2,000 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 940 nm 0.037 mil, non-modulated)
Enclosure: PBT, Slit cover: Polycarbonate
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Cable length
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. (Note 6)
Net weight: 3 g approx.
Weight
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) This is the value when a sensing object is moved in a lateral direction to the U-shape.
Selection
Guide
3) This is the value when a sensing object is moved in a lateral direction to the U-shape and when the inserting length of the sensing board is 5 mm 0.197 in.
4) The response frequency is the value when the disc, given in the figure below, is rotated.
U-shaped
Convergent
Reflective
1.8 mm 0.071 in
Disk
Disk
PM-64
PM-24
PM-44/
PM-54
t = 0.2 mm 0.008 in
1.6 mm 0.063 in
1.6 mm 0.063 in
5) 5-35% RH in an ambient temperature of +23 °C +73.4 °F.
6) Confirm that the sensor terminal voltage is more than 4.5 V when using an extension of over 20 m 65.617 ft.
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64SERIES
447
FIBER
I/O CIRCUIT AND WIRING DIAGRAMS
SENSORS
LASER
SENSORS
NPN output type
PM-□64(W)
PHOTO-
ELECTRIC
SENSORS
I/O circuit diagram
Terminal arrangement diagram
MICRO
PHOTO-
Color code of connector attached cable
ELECTRIC
SENSORS
(Brown) +V
(Black) Output 1
(Note 1,2)
ZD1
AREA
Load
SENSORS
Load
+
–
5 to 24 V DC
10 %
50 mA max.
Tr1
LIGHT
(White) Output 2 (Note 1,2)
50 mA max.
CURTAINS
ZD2
Tr2
1
2
3
4
PRESSURE /
FLOW
(Blue) 0 V
SENSORS
Terminal No.
Designation
+V
INDUCTIVE
PROXIMITY
SENSORS
Internal circuit
Users’ circuit
1
2
3
4
Notes: 1) Make sure to connect terminals correctly as the sensor does not
incorporate a reverse polarity protection circuit.
Output1: Light-ON
Output2: Dark-ON
0 V
PARTICULAR
USE
Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a
capacitive load. Faulty wiring may result in damage.
2) Ensure to insulate the unused output wire.
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Symbols … ZD1, ZD2 : Surge absorption zener diode
Tr1,Tr2 : NPN output transistor
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
PNP output type
PM-□64P
SENSORS
I/O circuit diagram
Color code of connector attached cable
(Brown) +V
Terminal arrangement diagram
STATIC
CONTROL
DEVICES
ENDOSCOPE
ZD1
50 mA max.
LASER
MARKERS
Tr1
ZD2
+
–
5 to 24 V DC
10 %
(Black) Output 1 (Note 1,2)
50 mA max.
PLC /
Load
Tr2
1
2
3
4
TERMINALS
(White) Output 2 (Note 1,2)
Load
(Blue) 0 V
HUMAN
MACHINE
Terminal No.
Designation
+V
INTERFACES
Internal circuit
Users’ circuit
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
1
2
3
4
Notes: 1) Make sure to connect terminals correctly as the sensor does not
incorporate a reverse polarity protection circuit.
Output1: Light-ON
Output2: Dark-ON
0 V
Further, the output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a
capacitive load. Faulty wiring may result in damage.
2) Ensure to insulate the unused output wire.
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
Symbols … ZD1, ZD2 : Surge absorption zener diode
Tr1,Tr2 : PNP output transistor
SYSTEMS
SENSING CHARACTERISTICS (TYPICAL)
Selection
Guide
U-shaped
PM-K64(P) PM-L64(P)
Convergent
Reflective
Sensing position
PM-64
PM-24
Dark-
ON
Dark-
ON
PM-44/
PM-54
9 mm 0.354 in
ℓ
7 mm 0.276 in
ℓ
2.6 mm
0.102 in
Beam
axis
Light-
ON
Light-
ON
0
1
2
3
4
1
2
3
4
0.039
0.079
0.118
0.157
0.039
0.079
0.118
0.157
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64SERIES
448
PRECAUTIONS FOR PROPER USE
FIBER
Refer to General precautions.
SENSORS
LASER
SENSORS
Cable extension
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
PHOTO-
• Cable extension is possible up to an overall length of
100 m 328.084 ft with a 0.3 mm2, or more, cable.
However, since a voltage drop shall occur due to the
cable extension, ensure that the power supply voltage
at the end of the cable attached to the sensor or at the
sensor terminals is within the rating.
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
Total cable length ±11 m 328.184 ft
LIGHT
CURTAINS
Connector
+V
attached cable
Extension cable
Make sure to connect terminals correctly as the
sensor does not incorporate a reverse polarity
protection circuit.
PRESSURE /
FLOW
+
–
5 to 24V DC
±±1 %
Output
1 V
SENSORS
Supply voltage:
4.5 V or more
INDUCTIVE
PROXIMITY
SENSORS
Further, the output is not incorporated with a
short-circuit protection circuit. Do not connect it
directly to a power supply or a capacitive load.
Faulty wiring may result in damage.
But, when the overall cable length, including the cable
attached to the sensor, is as given below, there is no
need to confirm the voltage.
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Conductor cross-
section area of
extension cable
SIMPLE
Mounting
Total cable length
WIRE-SAVING
UNITS
• When fixing the sensor with screws, use M3 screws and
the tightening torque should be 0.5 N·m or less.
Further, use small, round type plain washers (ø6 mm
ø0.236 in).
0.08 to 0.1 mm2
Up to 5 m 16.404 ft
Up to 10 m 32.808 ft
Up to 20 m 65.617 ft
WIRE-SAVING
SYSTEMS
0.2 mm2
MEASURE-
MENT
0.3 mm2
SENSORS
STATIC
M3 screws
CONTROL
DEVICES
Others
ENDOSCOPE
Spring washer
• Since the sensor is intended for
use inside machines, no special
countermeasures have been
taken against extraneous light.
Take care that extraneous light is
not directly incident on the beam
receiving section.
Plain washer
Outer diameter
ø6 mm
LASER
(
)
MARKERS
ø0.236 in
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Wiring
• If the sensor is used in a place having excessive dust,
periodically clean the emitting and receiving sections with
a dry, soft cloth.
• If there is a large surge generating equipment, such as,
motor, solenoid, electromagnetic valve, etc., in the vicinity
of the sensor, use a surge absorber on that equipment.
Further, do not run the sensor cables along power lines
and use a capacitor between +V and 0 V, if required.
Use the sensor after confirming that the surge has been
eliminated.
FA
Connection method
COMPONENTS
Projection
• Insert the connector attached cable
CN-14A(-R)-C□ in the connector part
of this product as shown in the right
figure.
MACHINE
VISION
SYSTEMS
CN-14A(-R)-C□
<Connector>
UV
CURING
SYSTEMS
Housing: PAP-04V-S
Manufactured by J.S.T.
(
)
Mfg. Co., Ltd.
<Connector pin position>
Selection
Guide
1
2
3
4
Connector pin No.
Terminal designation
U-shaped
Output 1 Output 2
+V
0V
4
1
2
3
Convergent
Reflective
Disconnection method
• Pressing the projection of the connector attached cable,
pull out the connector.
PM-64
PM-24
Note: Take care that if the cable is pulled out without pressing the projection,
the cable may break.
PM-44/
PM-54
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64SERIES
449
FIBER
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from our website.
SENSORS
LASER
SENSORS
Sensor
Sensor
PM-K64(P)
PM-T64(P)
PHOTO-
ELECTRIC
SENSORS
26
1.024
20
13.7
0.539
3.5
7
0.138
MICRO
PHOTO-
0.276
0.787
3
ELECTRIC
SENSORS
0.118
7
Beam axis
0.276
AREA
SENSORS
2-ø3.2 ø0.126 mounting holes
7
Beam axis
0.276
Operation indicator
(Orange)
13.4
0.528
0.5197
Operation indicator
LIGHT
6.8
CURTAINS
(Orange)
2.6
0.268
Beam axis width:
0.8 0.031
0.102
PRESSURE /
FLOW
13.4
0.528
0.5197
26
Beam axis
SENSORS
Beam axis width:
9
2.6
1.024
0.8 0.031
0.354
Locking
3.2
0.102
INDUCTIVE
PROXIMITY
SENSORS
13.8
part
23
0.126
0.543
6.2
4.1
0.906
0.244
Beam axis
7.4
0.161
9
3.2
PARTICULAR
USE
0.291
0.354
13
0.126
23
SENSORS
0.512
2.1
(
)
0.906
3.7
0.146
1.7
0.083
10.5
SENSOR
OPTIONS
7.4
0.413
2-mounting oblong holes
0.291
0.067
2.1
Connector attached cable CN-14A(-R)-C□ (Optional)
20
Locking
part
(
)
0.083
SIMPLE
WIRE-SAVING
UNITS
0.787
1.6
20
2-mounting
oblong holes
Connector attached cable
0.063
0.787
CN-14A(-R)-C□ (Optional)
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
Sensor
Sensor
PM-T64W
PM-L64(P)
SENSORS
STATIC
CONTROL
DEVICES
16.7
26.2
0.657
1.031
20
10
1.7 0.067
3.7 0.146
3.5
0.787
0.394
0.138
4
ENDOSCOPE
0.157
7
Beam axis
2-mounting oblong holes
0.276
15.7
LASER
0.618
7
MARKERS
3.2
Beam axis
0.276
0.126
Operation indicator (Orange)
Locking part
PLC /
Operation indicator
(Orange)
TERMINALS
2.1
Connector attached cable
(
)
0.083
12.8
13.4
HUMAN
MACHINE
CN-14A(-R)-C□ (Optional)
Beam axis width:
0.8 0.031
0.504
0.528
0.5197
2.6
6.4
INTERFACES
13.4
0.102
0.252 Beam axis width:
0.8 0.031
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
0.528
5
4.1
2.6
8.3
0.161
0.102 0.327
Beam axis
9
0.197
3.2
0.354
13
0.126
Beam axis
23
9
0.512
FA
0.906
0.354
15.5
PM-L64
COMPONENTS
6
10.5
0.610
PM-L64
0.236
7.2
7.4
0.413
MACHINE
VISION
0.283
0.291
2.1
9
Locking
part
SYSTEMS
20
(
)
0.083
20
2-ø3.2 ø0.126 mounting holes
0.354
0.787
1.6
0.787
26
UV
CURING
0.063
2-mounting
oblong holes
Connector attached cable
CN-14A(-R)-C□ (Optional)
SYSTEMS
1.024
Selection
Guide
Sensor
Sensor
PM-Y64(P)
PM-F64(P)
U-shaped
3
2-ø3.5 ø0.138 mounting holes
0.118
Convergent
3.5
7
Reflective
0.138
0.276
Beam axis and boss
7
0.276
7
PM-64
PM-24
0.276
22.7
Operation indicator (Orange)
Beam axis
Center of beam axis
and boss
0.894
ø2.4 ø0.094
7
2.5
Operation indicator (Orange)
Locking part
13.4
0.528
5
PM-44/
PM-54
0.276
0.098
Beam axis width:
0.8 0.031
Center of beam
axis and boss
2.6
0.102
0.197
2.1
Connector attached cable
(
)
0.083
CN-14A(-R)-C□ (Optional)
12.8
0.504
13.8
0.543
5
9
0.354
23
0.906
6.4
16.3
0.252
2.6
0.642
Beam axis width:
0.8 0.031
9
0.102
0.354
0.197
8.2
0.323
Beam axis
2.5
15.5
Locking part
7
0.098
12.9
ø3.2 ø0.126
mounting holes
0.610
2.1
0.276
14
Connector attached cable
0.508
6.5
0.256
(
)
0.083
CN-14A(-R)-C□ (Optional)
0.551
Connector Built-in U-shaped Micro Photoelectric Sensor PM-64SERIES
450
DIMENSIONS (Unit: mm in)
FIBER
The CAD data in the dimensions can be downloaded from our website.
SENSORS
LASER
SENSORS
Sensor
PM-R64(P)
PHOTO-
ELECTRIC
SENSORS
3
0.118
MICRO
Beam axis and boss
PHOTO-
ELECTRIC
SENSORS
7
0.276
AREA
SENSORS
Operation indicator (Orange)
Center of beam
axis and boss
ø2.4
ø0.094
2.5
0.098
2.6
13.4
0.528
5
7
LIGHT
CURTAINS
0.276
Beam axis width:
0.8 0.031
Center of beam axis
and boss
0.102
0.197
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
16.3
23
0.906 9
0.354
0.642
8.2
PARTICULAR
USE
0.323
SENSORS
7
ø3.2 ø0.126
Locking part
SENSOR
OPTIONS
0.276
14
2.1
mounting holes
(
)
0.083
Connector attached cable
0.551
CN-14A(-R)-C□ (Optional)
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Connector attached cable (Optional)
CN-14A-C□ CN-14A-R-C□
MEASURE-
MENT
SENSORS
L
• Length L
STATIC
35
50
CONTROL
DEVICES
(
)
(
)
1.378
1.969
Model No.
Length L
8
8
(
)
(
)
0.315
1,000 39.370
2,000 78.740
3,000 118.110
5,000 196.850
CN-14A(-R)-C1
CN-14A(-R)-C2
CN-14A(-R)-C3
CN-14A(-R)-C5
0.315
ENDOSCOPE
LASER
MARKERS
ø3.7 ø0.146 cable
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
U-shaped
Convergent
Reflective
PM-64
PM-24
PM-44/
PM-54
相关型号:
©2020 ICPDF网 联系我们和版权申明