RPA30-2412DAW/N [ETC]

DC DC CONVERTER +/-12V 30W;
RPA30-2412DAW/N
型号: RPA30-2412DAW/N
厂家: ETC    ETC
描述:

DC DC CONVERTER +/-12V 30W

文件: 总9页 (文件大小:1072K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 4:1 wide input voltage range  
• 1.6kVDC Isolation  
Features  
DC/DC Converter  
• UL, IEC/EN60950 and EN50155 certified  
• Efficiency up to 89%  
Regulated  
Converter  
• OVP, OCP & OTP  
• +105°C max. case temperature  
RPA30-AW  
Description  
30 Watt  
The RPA30-AW series are high power density, wide input voltage range 30W DC/DC converters in  
3
an industry standard 1”x1” case size. Despite their small size, the RPA30-AW converters are fully 1“ x 1“  
specified devices with output currents up to 7.5Amps, up to 89% efficiency, no minimum load, 1600VDC  
isolation, tight regulation and low ripple/noise figures. The outputs are also fully protected against  
Single & Dual  
over-temperature, short circuits, overcurrent and overvoltage and the single output version  
offers a 10% trim range. A heatsink option is available to extend the operating temperature range.  
The converters are UL and EN50155 certified and will find many uses in railway and industrial  
applications where board space is at a premium.  
Output  
Selection Guide  
Part Number  
Input  
Output  
Output  
Current  
[mA]  
7500  
6000  
2500  
2000  
1250  
1000  
Input (1) Efficiency (1) Max. Capacitive  
Voltage Range Voltage  
Current  
[mA]  
typ.  
[%]  
Load  
[µF]  
[VDC]  
9-36  
9-36  
9-36  
9-36  
9-36  
9-36  
[VDC]  
3.3  
5
12  
15  
RPA30-243.3SAW (2,3)  
RPA30-2405SAW (2,3)  
RPA30-2412SAW (2,3)  
RPA30-2415SAW (2,3)  
RPA30-2412DAW (2,3)  
RPA30-2415DAW (2,3)  
1172  
1404  
1420  
1420  
1420  
1420  
88  
89  
88  
88  
88  
88  
10000  
10000  
1000  
1000  
1000  
680  
12  
15  
RoHS2  
+
REACH  
compliant  
compliant  
10 from 10  
E224736  
Notes:  
Note1: Tested at nominal Vin, full load and at +25°C ambient  
Model Numbering  
UL60950-1 certified  
IEC/EN60950-1 certified  
EN50155 certified  
CB report  
RPA30-__ __ _AW/_ _  
(3)  
nom. Input Voltage  
“Package  
(2)  
nom. Output Voltage  
“CTRL Logic  
Single or Dual  
Notes:  
Note2: no suffix for standard part without CTRL pin, trim pin fitted  
add suffix “P” for positive CTRL function (1=ON, 0=OFF), trim pin fitted  
add suffix “N” for negative CTRL function (0=ON, 1=OFF), trim pin fitted  
trim pin is only available for single outputs  
Note3: add suffix “-HC” for glued Heat-sink (compatible with all other suffixes)  
Ordering Examples  
RPA30-243.3SAW = 24V input, 3.3V output, single, no CTRL pin  
RPA30-2405SAW/P = 24V input, 5V output, single, positive CTRL function  
RPA30-2415SAW-HC = 24V input, 15V output, single, no CTRL pin, glued Heat-sink  
RPA30-2415DAW/N-HC = 24V input, 15V output, dual, negative CTRL function, glued Heat-sink  
www.recom-power.com  
REV.: 7/2020  
PD-1  
RPA30-AW  
DC/DC Converter  
Specifications (masured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)  
Series  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
Internal Input Filter  
Input Voltage Range  
Input Surge Voltage  
Pi-Type  
nom. Vin= 24VDC  
100ms max.  
9VDC  
24VDC  
36VDC  
50VDC  
DC-DC ON  
DC-DC OFF  
8VDC  
7VDC  
8.5VDC  
7.5VDC  
9VDC  
8VDC  
Under Voltage Lockout (UVLO)  
Quiescent Current  
Output Voltage Trimming  
Minimum Load  
20mA  
-10%  
0%  
55mA  
+10%  
refer to “OUTPUT VOLTAGE TRIMMING”  
Power up  
CTRL ON/OFF  
Start-up time  
8ms  
16ms  
DC-DC ON  
DC-DC OFF  
Open or 2.4VDC < VCTRL < 10VDC  
Short or 0VDC < VCTRL< 0.8VDC  
Positive Logic  
Negative Logic  
ON/OFF CTRL  
DC-DC ON  
DC-DC OFF  
Short or 0VDC < VCTRL < 0.8VDC  
Open or 2.4VDC < VCTRL < 10VDC  
6mA  
Input current of CTRL pin  
Internal Operating Frequency  
Ripple and Noise  
550kHz  
20MHz BW, 10µF tantalum capacitor and 1µF ceramic capacitor  
50mVp-p  
RPA30-243.3SAW  
Efficiency vs. Output Current  
Power Dissipation vs. Output Current  
6
5.5  
5
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
4.5  
4
3.5  
3
2.5  
2
1.5  
1
9Vin  
24Vin  
36Vin  
9Vin  
24Vin  
36Vin  
0.5  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
1.5  
3
4.5  
6
7.5  
Output Current [%]  
Output Current [A]  
RPA30-2405SAW  
Efficiency vs. Output Current  
Power Dissipation vs. Output Current  
5.5  
5
100  
90  
4.5  
4
80  
70  
60  
50  
40  
30  
20  
10  
3.5  
3
2.5  
2
1.5  
1
9Vin  
24Vin  
36Vin  
9Vin  
24Vin  
36Vin  
0.5  
0
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
1
2
3
4
5
6
Output Current [%]  
Output Current [A]  
continued on next page  
REV.: 7/2020  
www.recom-power.com  
PD-2  
RPA30-AW  
DC/DC Converter  
Specifications (masured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)  
Series  
RPA30-2412SAW  
Efficiency vs. Output Current  
Power Dissipation vs. Output Current  
5.5  
100  
5
4.5  
4
90  
80  
70  
60  
50  
40  
3.5  
3
2.5  
2
30  
1.5  
9Vin  
24Vin  
36Vin  
9Vin  
24Vin  
36Vin  
20  
1
0.5  
0
10  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
0.5  
1
1.5  
2
2.5  
Output Current [%]  
Output Current [A]  
RPA30-2415SAW  
Efficiency vs. Output Current  
Power Dissipation vs. Output Current  
100  
90  
5.5  
5
4.5  
4
80  
70  
60  
50  
40  
30  
20  
10  
3.5  
3
2.5  
2
1.5  
1
9Vin  
24Vin  
36Vin  
9Vin  
24Vin  
36Vin  
0.5  
0
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
0.4  
0.8  
1.2  
1.6  
2
Output Current [%]  
Output Current [A]  
RPA30-2412DAW  
Efficiency vs. Output Current  
Power Dissipation vs. Output Current  
100  
90  
5.5  
5
4.5  
4
80  
70  
60  
50  
40  
30  
20  
10  
3.5  
3
2.5  
2
1.5  
1
9Vin  
24Vin  
36Vin  
9Vin  
24Vin  
36Vin  
0.5  
0
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
0.25  
0.5  
0.75  
1
1.25  
Output Current [%]  
Output Current [A]  
continued on next page  
www.recom-power.com  
REV.: 7/2020  
PD-3  
RPA30-AW  
DC/DC Converter  
Specifications (masured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)  
Series  
RPA30-2415DAW  
Efficiency vs. Output Current  
Power Dissipation vs. Output Current  
100  
90  
5.2  
4.4  
3.6  
2.8  
2.0  
80  
70  
60  
50  
40  
30  
9Vin  
24Vin  
36Vin  
9Vin  
24Vin  
36Vin  
1.2  
20  
10  
0
0.4  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
0
0.2  
0.4  
0.6  
0.8  
1
Output Current [%]  
Output Current [A]  
OUTPUT VOLTAGE TRIMMING  
Output Voltage Trimming  
RPA30-AW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim  
resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may  
slightly vary.  
Trim up  
Trim down  
-Vout  
Trim  
Trim  
R
R
D
U
+Vout  
RPA30-243.3SAW  
Trim up  
Vout =  
RU =  
1
2
3
4
5
6
7
8
9
10  
[%]  
3.33  
402  
3.36  
169  
3.39  
100  
3.43  
75  
3.46  
47.5  
3.49  
34.8  
3.53  
26.1  
3.56  
17.8  
3.59  
12.1  
3.63  
8.06  
[VDC]  
[kΩ]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
[%]  
[VDC]  
[kΩ]  
3.27  
402  
3.23  
191  
3.20  
113  
3.17  
75  
3.14  
52.3  
3.10  
39.2  
3.07  
26.7  
3.04  
20  
3.0  
2.97  
8.06  
12.1  
RPA30-2405SAW  
Trim up  
Vout =  
RU =  
1
2
3
4
5
6
7
8
9
10  
[%]  
[VDC]  
[kΩ]  
5.05  
604  
5.10  
243  
5.15  
147  
5.20  
95.3  
5.25  
68.1  
5.30  
39.2  
5.35  
34.8  
5.40  
22.1  
5.45  
15  
5.50  
8.06  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
4.50  
0.5  
[%]  
[VDC]  
[kΩ]  
4.95  
604  
4.90  
287  
4.85  
169  
4.80  
124  
4.75  
105  
4.70  
78.7  
4.65  
54.9  
4.60  
39.2  
4.55  
15  
RPA30-2412SAW  
Trim up  
Vout =  
RU =  
1
2
3
4
5
6
7
8
9
10  
13.20  
10  
[%]  
[VDC]  
[kΩ]  
12.12  
604  
12.24  
267  
12.36  
162  
12.48  
105  
12.6  
75  
12.72  
499  
12.84  
40.2  
12.96  
24.9  
13.08  
18.2  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
[%]  
[VDC]  
[kΩ]  
11.88  
750  
11.76  
309  
11.64  
200  
11.52  
124  
11.40  
90.9  
11.28  
64.9  
11.16  
45.3  
11.04  
32.4  
10.92  
20  
10.80  
12.1  
continued on next page  
REV.: 7/2020  
www.recom-power.com  
PD-4  
RPA30-AW  
DC/DC Converter  
Specifications (masured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)  
Series  
RPA30-2415SAW  
Trim up  
Vout =  
RU =  
1
2
3
4
5
6
7
8
9
10  
16.50  
10  
[%]  
[VDC]  
[kΩ]  
15.15  
1000  
15.30  
243  
15.45  
200  
15.60  
130  
15.75  
90.9  
15.90  
61.9  
16.05  
40.2  
16.20  
30.1  
16.35  
24.9  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
[%]  
[VDC]  
[kΩ]  
14.85  
1000  
14.70  
348  
14.55  
210  
14.40  
140  
14.25  
95.3  
14.10  
68.1  
13.95  
45.3  
13.80  
30.1  
13.65  
18.2  
13.50  
8.06  
REGULATION  
Parameter  
Condition  
Value  
Output Accuracy  
2.0% max.  
single  
dual  
0.2% max.  
0.5% max.  
Line Regulation  
low line to high line, full load  
3.3Vout  
5Vout  
12Vout, 15Vout  
12Vout, 15Vout  
0.3%  
0.2%  
0.1%  
1.0%  
Load Regulation  
Cross Regulation  
asymmetrical 25%<>100% load  
50-75%, full load, 0.1A/µs  
25% load step change  
3.0% max.  
3.0% Vout typ.  
250µs typ.  
Transient Response  
PROTECTION  
Parameter  
Condition  
Value  
Short Circuit Protection (SCP)  
Over Voltage Protection (OVP)  
Over Current Protection (OCP)  
below 100mΩ  
continuous, auto recovery  
115%-150% Output Voltage, Hiccup, auto recovery  
110%-160% Output Current, Hiccup  
Over Temperature Protection (OTP)  
Isolation Voltage (4)  
+115°C 5°C  
1.6kVDC  
I/P to O/P  
tested for 1 minute  
Isolation Resistance  
10MΩ min.  
1100pF typ.  
basic  
Isolation Capacitance  
Insulation Grade  
Notes:  
Note4: For repeat Hi-Pot testing, reduce the time and/or the test voltage  
Note5: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: 4A slow blow type  
ENVIRONMENTAL  
Parameter  
Condition  
Value  
refer to ”Thermal Calculation”  
+105°C  
Operating Temperature Range (6)  
Maximum Case Temperature  
Temperature Coefficient  
Thermal Impedance  
Operating Altitude  
Operating Humidity  
Shock  
0.02%/K  
refer to ”Table 1: Thermal Impedance”  
2000m  
non-condensing  
95% RH  
5G, 30ms, 6 times along X,Y and Z axis  
10-500Hz, 2.4G, 30mins along X,Y and Z axis  
5888 x 103 hours  
Vibration  
MTBF  
according to Telcordia SR332 3  
+25°C  
continued on next page  
REV.: 7/2020  
www.recom-power.com  
PD-5  
RPA30-AW  
DC/DC Converter  
Specifications (masured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)  
Series  
Table 1:Thermal Impedance  
without Heatsink  
airflow Rth without PCB Rth with PCB  
with Heatsink  
Rth without PCB Rth with PCB (6)  
(6)  
[m/s]  
0.1  
0.2  
0.5  
1.0  
1.5  
2.0  
[K/W]  
17.8  
16.0  
14.0  
10.0  
8.3  
[K/W]  
12.5  
11.2  
9.7  
[K/W]  
16.0  
14.4  
12.6  
9.0  
[K/W]  
11.3  
10.1  
8.7  
Notes:  
Note6:Test PCB: 160x100mm 105µm (Eurocard), double layer  
7.1  
6.4  
5.8  
7.5  
5.2  
6.3  
4.4  
5.7  
4.0  
Thermal Calculation  
choose your model:  
choose your model:  
RPA30-2405SAW (with PCB (6)  
)
RPA30-2405SAW-HC (with PCB (6)  
)
• Load conditions in application (e.g. 50%)  
• Airflow conditions in application (e.g. 0.5m/s)  
• use Rth from Table1 (9.7K/W)  
• Load conditions in application (e.g. 50%)  
• Airflow conditions in application (e.g. 0.5m/s)  
• use Rth from Table1 (8.7K/W)  
Calculation:  
Calculation:  
Iout = 50%  
Iout = 50%  
Rth = 9.7K/W  
PDISS = 2.2W  
TCASEmax = 105°C  
Rth = 8.7K/W  
PDISS = 2.2W  
TCASEmax = 105°C  
TOVER = R x P  
TAMBmax = TCASEmax - TOVER = 105°C - 21.3°C  
= 9.7K/W x 2.2W  
=
21.3°C  
83.7°C  
TOVER = R x P = 8.7K/W x 2.2W  
Dis  
TAMBmax = TCASEmax - TOVER = 105°C - 19.1°C  
=
19.1°C  
= 85.9°C  
th  
Dis  
th  
=
RPA30-2405SAW  
RPA30-2405SAW-HC  
100  
90  
80  
70  
60  
50  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
40  
30  
20  
10  
0
Nature Convection (0.1m/s)  
Nature Convection (0.1m/s)  
0.2m/s  
0.5m/s  
1.0m/s  
1.5m/s  
2.0m/s  
0.2m/s  
0.5m/s  
1.0m/s  
1.5m/s  
2.0m/s  
-40  
20  
40  
60  
80  
100 110  
-40  
20  
40  
60  
80  
100 110  
85.9  
Ambient Temperature [°C] 83.7  
Ambient Temperature [°C]  
SAFETY AND CERTIFICATIONS  
Certificate Type (Safety)  
Report / File Number  
Standard  
UL60950-1, 2nd Edition, 2014  
CSA C22.2 No. 60950-1-07, 2nd Edition, 2014  
Information Technology Equipment - General Requirements for Safety  
E224736-A39 + A40  
Information Technology Equipment - General Requirements for Safety  
(CB Scheme)  
IEC60950-1:2005, 2nd Edition + A2:2013  
E224736-A39-CB + A40-CB  
Information Technology Equipment - General Requirements for Safety  
EN60950-1:2006 + A2:2013  
EN50155:2007, Clause 5.4 and 5.5  
TP TC 004/2011  
Railway applications – Electronic equipment used on rolling stock  
15100175 001, 15100176 001  
RU-AT.49.09571  
EAC  
RoHS 2  
RoHS 10/10, 2011/65/EU + AM-2015/863  
continued on next page  
www.recom-power.com  
REV.: 7/2020  
PD-6  
RPA30-AW  
DC/DC Converter  
Specifications (masured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)  
Series  
EMC Compliance  
Condition  
Standard / Criterion  
with external filter  
(see filter suggestion below)  
Electromagnetic compatibility of multimedia equipment - Emission requirements  
EN55032, Class A  
Railway applications - Electromagnetic compatibility  
Part 3-2: Rolling stock - Apparatus  
EN50121-3-2:2015  
EN55016-2-1:2009  
Specification for radio disturbance and immunity measuring apparatus and  
methods Part 2-1: Methods of measurement of disturbances and immunity – Con-  
ducted disturbance measurements  
Specification for radio disturbance and immunity measuring apparatus and  
methods Part 2-3: Methods of measurement of disturbances and immunity –  
Radiated disturbance measurements  
EN55016-2-3:2010  
ESD Electrostatic discharge immunity test  
Air 8kV, Contact 6kV  
EN61000-4-2:2009, Criteria A  
20V/m, 80-1000MHz  
10V/m, 1.4-2.0GHz  
5V/m, 2.0-2.7GHz  
3V/m, 5.1-6.0GHz  
Radiated, radio-frequency, electromagnetic field immunity test  
EN61000-4-3:2006, Criteria A  
Fast Transient and Burst Immunity  
DC Power Port 2kV  
DC Power Port 1kV  
DC Power Port 10V  
IEC61000-4-4:2004, Criteria A  
EN61000-4-5:2006, Criteria A  
EN61000-4-6:2009, Criteria A  
Surge Immunity  
Immunity to conducted disturbances, induced by radio-frequency fields  
EMC Filtering according to EN50121-3-2 and EN55032 Class A  
L1  
F1  
+Vin  
+Vout  
+Vin  
+Vout  
D1(7)  
C1  
-Vin  
-Vout  
-Vin  
-Vout  
Notes:  
Note7: Diode is only needed for EN50155  
C1  
L1  
47µF/50V  
electrolyte capacitor  
1µH choke  
DIMENSIONS and PHYSICAL CHARACTERISTICS  
Parameter  
Type  
case  
baseplate  
potting  
Value  
al alloy, anodize black  
non-conductive FR4  
silicone (UL94 V-0)  
Material  
without Heat-sink  
with Heat-sink  
25.4 x 25.4 x 10.2mm  
25.4 x 25.4 x 16.8mm  
Dimensions (LxWxH)  
Weight  
without Heat-sink  
with Heat-sink  
17g typ.  
21g typ.  
continued next page  
REV.: 7/2020  
www.recom-power.com  
PD-7  
RPA30-AW  
DC/DC Converter  
Specifications (masured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)  
Series  
Dimension Drawing (mm)  
25.4  
25.4  
Pin Connections  
0.1  
Ø 1.0  
Pin #  
Single  
+Vin  
Dual  
+Vin  
Recommended Footprint Details  
1
2
3
4
5
6
-Vin  
-Vin  
2.54  
20.32  
6 x Ø1.5  
CTRL (2)  
-Vout  
Trim  
CTRL (2)  
-Vout  
Com  
6
5
4
3
4
5
6
2
1
1
2
Bottom View  
Top View  
+Vout  
+Vout  
Pin Pitch Tolerance 0.25mm  
xx.x= 0.5mm  
xx.xx= 0.25mm  
3
Heat-sink Dimension Drawing (mm)  
25.4  
Ø 1.0  
www.recom-power.com  
REV.: 7/2020  
PD-8  
RPA30-AW  
DC/DC Converter  
Specifications (masured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)  
Series  
PACKAGING INFORMATION  
Parameter  
Type  
Value  
without Heat-sink  
with Heat-sink  
285.0 x 27.6 x 19.0mm  
285.0 x 27.6 x 25.8mm  
Packaging Dimensions (LxWxH)  
tube  
Packaging Quantity  
10pcs  
-55°C to +125°C  
5% - 95% RH  
Storage Temperature Range  
Storage Humidity  
non-condensing  
The product information and specifications may be subꢀect to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The  
products are not authorized for use in safety-critical applications without RECOMꢁs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause  
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized  
use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 7/2020  
PD-9  

相关型号:

RPA30-2412DAW/N-HC

DC DC CONVERTER +/-12V 30W
ETC

RPA30-2412DAW/P-HC

DC DC CONVERTER +/-12V 30W
ETC

RPA30-2412SAW

4:1 Wide Input Voltage Range
RECOM

RPA30-2412SAW-HC

DC DC CONVERTER 12V 30W
ETC

RPA30-2412SAW/N

DC DC CONVERTER 12V 30W
ETC

RPA30-2412SAW/N-HC

DC DC CONVERTER 12V 30W
ETC

RPA30-2415DAW

4:1 Wide Input Voltage Range
RECOM

RPA30-2415DAW-HC

DC DC CONVERTER +/-15V 30W
ETC

RPA30-2415DAW/N

DC DC CONVERTER +/-15V 30W
ETC

RPA30-2415DAW/N-HC

DC DC CONVERTER +/-15V 30W
ETC

RPA30-2415DAW/P

DC DC CONVERTER +/-15V 30W
ETC

RPA30-2415DAW/P-HC

DC DC CONVERTER +/-15V 30W
ETC