V23105-A5478-A201*SPEC* [ETC]
RELAY DPCO 48VDC ((NS)) ; 继电器DPCO 48VDC ( ( NS ) )\n型号: | V23105-A5478-A201*SPEC* |
厂家: | ETC |
描述: | RELAY DPCO 48VDC ((NS))
|
文件: | 总7页 (文件大小:78K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Small Relay D2 neutral
Product Information
Small Relay D2 neutral
V23105
PCB relay for DC operation,
neutral, monostable
Features
O
All purpose relay with 2 changeover contacts,
suitable for a wide range of applications
O
Four different coil versions available
(150, 200, 400, 500 mW)
O
O
O
The switching capacity ranges from low signal up to 3 A
Standard Pinning
ECR1029-R
Approx. 1.5 x original size
High-voltage resistance according to FCC Part 68:
1.5 kV (10/160 µs)
Typical applications
Version
O
O
O
O
Communications technology
–
–
–
–
–
Monostable, 1 winding
Telecommunications terminal and accessories
Entertainment electronics
With 2 changeover contacts
For printed circuits assembling
Plastic case
Measurement and control equipment
Immersion cleanable
Approvals
UL
File E 48393
CSA
File LR 45064-27
Spec. T4563c
British Telecom BT47W
Dimension drawing (in mm)
Mounting hole layout
Terminal assignment
View on the terminals
View on the terminals
ECR1541-6
Basic grid 2.54 mm according to EN 60097 and DIN 40803
2
Siemens Electromechanical Components
Small Relay D2 neutral
Contact data
Number of contacts and type
Contact assembly
Contact material
2 changeover contacts
single contacts
Silver nickel, gold-plated,
against silver nickel, gold-plated
Max. continous current at max. ambient temperature
Maximum switching current
3 A
3 A
Maximum switching voltage
250 VDC
230 VAC
Maximum switching capacity
DC voltage
AC voltage
60 W, see load limit curve
120 VA
Recommended for load voltages greater than
Thermoelectrical potential
10 mV
< 15 µV
Contact resistance (initial value) / measuring current / driver voltage
≤ 100 mΩ / 10 mA / 20 mV
Load limit curve
ECR2265-5
300
250
200
150
U
100
80
60
50
40
30
20
10
0.1
0.2
0.3
0.4 0.5 0.6
0.8
1
1.5
2
3
4
5
I [A]
I
U
= switching current
= switching voltage
= recommended application field
Load limit curve: Quenching of the arc during the transit time
Siemens Electromechanical Components
3
Small Relay D2 neutral
Coil data
Nominal voltages
from 3 VDC to 48 VDC
Nominal power consumption of the various coil versions
150 mW
200 mW
400 mW
500 mW
Maximum operating voltage
150 mW
*)
80% of the nominal voltage
200/400/500 mW
70% of the nominal voltage
Minimum release voltage
5% of the nominal voltage
*) < 80% of the nominal voltage on request
U
U
=
=
Minimum voltage at 20 °C with after pre-energizing
with nominal voltage without contact current
Maximum continuous voltage at 20 °C
ECR2266-D
I
1.3
1.2
1.1
1.0
0.9
0.8
0.7
II
The operating voltage limits U and U are dependent on the tempe-
rature according to the formulae:
I
II
k
U
and
U
= k · U
I I 20 °C
I tamb
= k · U
II II 20 °C
II tamb
t
= Ambient temperature
= Minimum voltage at ambient temperature t
amb
U
U
I tamb
amb
= Maximum voltage at ambient temperature t
II tamb
amb
k a. k
= Factors (dependent on temperature), see diagram
I
II
0.6
0.5
0.4
-30 -20
10 20 30 40 50 60 70 80 85
-10
0
Ambient temperature tamb [°C]
4
Siemens Electromechanical Components
Small Relay D2 neutral
Coil versions
Nominal voltage
Operating voltage range
at 20 °C
Resistance
at 20 °C
Coil number
Ordering code block 2
U
nom
Minimum voltage U
Maximum voltage U
II
I
VDC
VDC
VDC
Ω
150 mW nominal power consumption
3
2.4
4.0
10.2
13.0
15.6
23.4
31.2
59.5
60
167
240
540
960
±
±
±
±
±
6
008
001
002
006
003
005
5
16.7
24
6
4.8
9
7.2
54
12
9.6
96
24
19.2
3480 ± 348
200 mW nominal power consumption
3
2.1
3.5
6.7
11.2
13.5
20.3
27.0
54.1
108.3
45
125
180
405
720
±
±
±
±
±
4.5
12.5
18
308
301
302
306
303
305
307
5
6
4.2
9
6.3
40.5
72
12
8.4
24
16.8
33.6
2880 ± 288
11520 ± 1152
48
400 mW nominal power consumption
5
3.5
4.2
7.9
9.5
62
90
±
±
±
±
6.2
9
401
402
406
403
405
407
6
9
6.3
14.3
19.1
38.3
76.6
203
360
20.3
36
12
8.4
24
16.8
33.6
1440 ± 144
5760 ± 576
48
500 mW nominal power consumption
5
6
3.5
4.2
6.3
8.9
36
70
±
±
±
±
±
3.6
7
501
502
506
504
503
505
507
9
6.3
12.5
15.0
17.8
34.4
67.3
140
200
280
14
10
12
24
48
7.0
20
28
8.4
16.8
33.6
1050 ± 105
4000 ± 400
Coil versions, BT 47 type / specification T4563C (current tested)
Nominal voltage
Operating current
Resistance
at 20 °C
British Telecom Code
Coil number
Ordering code block 2
U
nom
VDC
5
mA
80.0
32.5
27.0
14.0
7.0
Ω
36
200
280
±
±
±
3.6
20
28
47W/5
47W/9
47W/6
47W/7
47W/8
475
479
476
477
478
10
12
24
48
1050 ± 105
4000 ± 400
Siemens Electromechanical Components
5
Small Relay D2 neutral
General data
Operate time at U
Release time at U
Bounce time, typ.
and 20 °C, typ.
5 ms
4 ms
nom
without parallel diode, typ.
nom
3 ms
Maximum switching rate without load
20 operations/s
Ambient temperature according to
DIN IEC 61810-1 or VDE 0435 Part 201
150/200 mW nominal power consumption
400 mW nominal power consumption
500 mW nominal power consumption
-25 °C ... +85 °C
-25 °C ... +70 °C
-25 °C ... +60 °C
Thermal resistance
approx. 100 K/W
105 °C
Maximum permissible coil temperature
Vibration resistance,
10 to 55 Hz according to IEC 60068-2-6
55 to 500 Hz according to IEC 60068-2-6
function:10 g
damage: 20 g
Shock resistance, half sinus, 11 ms
according to IEC 68068-2-27
function:10 g
damage: 40 g
Degree of protection
immersion cleanable, IP 67
according to VDE 0470 Part 1 EN 60529 / IEC 60529
Capacitance at 1 kHz, 100 VAC
between open contacts
between closed contacts
between contact and coil
< 2 pF
< 1.5 pF
< 5 pF
Electrical endurance at resistive load
6 VDC / 100 mA
30 VDC / 1 A
30 VDC / 2 A (only 400 and 500 mW coils)
230 VAC / 500 mA
6
> 2 x 10 operations
5
approx. 5 x 10 operations
5
approx. 1 x 10 operations
5
> 3 x 10 operations
6
Mechanical endurance
Mounting position
Processing information
Weight
15 x 10 operations
any
Ultrasonic cleaning is not recommended
approx. 6 g
Insulation
Insulation resistance at 500 V
≥ 1000 MΩ
Dielectric test voltage (1 min)
contact/winding
changeover contact/changeover contact
at open contact
1000 VAC
750 VAC
750 VAC
/ 1500 VDC
/ 1000 VDC
/ 1000 VDC
rms
rms
rms
Surge voltage resistance
according to FCC 68 (10/160 µs)
1500 V
6
Siemens Electromechanical Components
Small Relay D2 neutral
Ordering code
V 2 3 1 0 5
A 5
A 2 0 1
Identification of the
small relay D2 neutral
Version
0 = 150 mW nominal power consumption
3 = 200 mW
4 = 400 mW
5 = 500 mW
Coil number
08 = 3 V nominal voltage (only coils with 150/200 mW nominal power consumption*)
01 = 5 V nominal voltage
02 = 6 V
06 = 9 V
04 = 10 V (only coil with 500 mW nominal power consumption)
03 = 12 V
05 = 24 V
07 = 48 V (not coil with 150 mW nominal power consumption)
BT 47 versions
475 = 5 V nominal voltage
479 = 10 V
476 = 12 V
477 = 24 V
478 = 48 V
Contact assembly / material
A201 = 2 changeover contacts, silver nickel, gold-plated, against silver nickel, gold-plated
*) Coils with 400/500 mW nominal power consumption on request
Ordering example: V23105-A5301-A201
Small relay D2 neutral, coil 5 V nominal voltage, 200 mW nominal power consumption,
Contact material silver nickel, gold-plated, against silver nickel, gold-plated
Siemens Electromechanical Components
7
相关型号: