TECHNOLOGIES
Product Data Sheet
60 WATT SINGLE OUTPUT
HIGH DENSITY DC/DC CONVERTER
VKA60xS Series
DESCRIPTION
FEATURES
G 18 - 36V & 33 - 75V INPUT RANGE
The VKA60xS Series DC/DC converters present an eco-
nomical and practical solution for distributed power
system architectures which require high power density
G SMALL SIZE: 2.28" X 2.4" X 0.50"
G HIGH EFFICIENCY: 87% TYPICAL AT 5V
and efficiency while maintaining system modularity and
upgradeability. With the ability to operate over a wide
input voltage range of 18 to 36 and 33 to 75 volts, these
modules are ideal for use in battery backup applications
common in todays' telecommunication and electronic
data processing applications. The output is fully isolated
from the input, allowing for a variety of polarity and
grounding configurations.
G 100µS TRANSIENT RESPONSE 50-100% LOAD STEP
G 420kHZ FIXED-FREQUENCY OPERATION
G OPERATION TO +100°C BASEPLATE TEMP.
G PRIMARY REMOTE ON/OFF, CHOICE OF POS/NEG
LOGIC
G ADJUSTABLE OUTPUT VOLTAGE
G REMOTE SENSE
The VKA60xS's proprietary control circuitry responds to
50-100% load steps in 100µSeconds to within 1% nomi-
nal Vout.
G CONTINUOUS SHORT-CIRCUIT PROTECTION
G THERMAL SHUTDOWN
The patented fixed frequency architecture combined with
surface mount technology results in a compact, efficient
and reliable solution to DC/DC conversion requirements.
G SAFETY PER UL1950, EN 60950 AND CSA 22.2 #234
G CASE GROUND PIN
Efficiency(%)
Efficiency(%)
Input
VOUT IOUT
Note (1)
Input
VOUT IOUT
Note (1)
Model
Voltage (VDC) (A)
Min
Typ
Model
Voltage (VDC) (A)
Min
Typ
81
VKA60MS03
3.3V
5.0V
12.0
12.0
6.0
81
86
88
89
89
82
87
89
90
90
VKA60LS03
VKA60LS05
VKA60LS12
VKA60LS15
VKA60LS24
3.3V
5.0V
12.0
12.0
6.0
80
85
87
88
89
VKA60MS05
VKA60MS12
VKA60MS15
VKA60MS24
48VDC
(33-75)
24VDC
(18-36)
86
12.0V
15.0V
24.0V
12.0V
15.0V
24.0V
88
4.0
4.0
89
2.5
2.5
90
AGENCYAPPROVALS
Internet: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369
Power Electronics Division,Europe
C&D Technologies (Power Electronics) Ltd.
132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland
Tel: +353.61.474.133
Fax:+353.61.474.141
VKA60xS Rev B 4/99
Page 1
COMMON SPECIFICATIONS
Specifications typical at TCASE = +40°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
VKA60LS
VKA60MS
18
33
24
48
36
75
VDC
VDC
Maximum Input Current
VKA60LS
VKA60MS
Reflected Ripple Current
Input Ripple Rejection
No Load Input Current LS/MS
Power Dissipation LS/MS
No Load
VIN = 16VDC
VIN = 27VDC
Peak - Peak
DC to 1KHz
4.4
2.6
A
A
mA
dB
mA
20
60
50/100
50
3.6/4.8
0.18/0.4
W
W
Standby, Primary On/Off Disabled LS/MS
Inrush Charge
VIN = VINmax.
VKA60LS
VKA60MS
0.520
0.360
mC
mC
Quiescent Operating Current
Primary On/Off Disabled
8
12
mA
OUTPUT
Rated Power
Set point Accuracy
LineRegulation
0
60
1
0.05
0.05
W
%
%
High Line to Low Line
No Load to Rated Load
0.02
0.02
.02
LoadRegulation
%
Output Temperature Drift
Output Ripple, p-p (4)
Output Current Limit Inception
Output Short-Circuit Current (5)
Output Overvoltage Limit
Transient Response
Peak Deviation
%/°C
VOUT, Nom
lOUT, Nom
lOUT, Nom
V
DC to 20MHz BW
test
1%
130%
110%
135%
125%
50 to 100% Load Step
di/dt = 1.0A/µSec
VOUT, 1% of Nominal Output
2%
100
V
, Nom
Settling Time
OµUTSec
ISOLATION
Input to Output
Input to Baseplate
Output to Baseplate
Resistance
Capacitance
Leakage Current
Peak Test for 2 Seconds
VISO = 240VAC, 60Hz
1500
1500
500
10
VDC
VDC
VDC
MΩ
2000
180
pF
µA, rms
GENERAL
Efficiency, Line, Load, Temp. (3)
Switching Frequency
Remote Sense Compensation
Output Voltage Adjust Range-12V & higher(4)
Remote On/Off Control Inputs
Primary
400
420
440
0.5
KHz
V
VOUT, Nom
-50% / +25%
Open Collector/Drain
Sink Current-Logic Low
Vlow
1.0
1
mA
V
Vhigh
2
V
Turn-on Time
Weight
Within 1% of Rated Output
10.0
12.5
85 (3.0)
mSec
g (oz.)
TEMPERATURE
Operation/Specification
Storage
Case Temperature
Case Temperature
Case Temperature
-40
-55
+25
+25
+100
+125
+115
°C
°C
ShutdownTemperature
ThermalImpedance,case-ambient
Lead Solder Temperature
+100
°C
7.1
°C/W
°C
10 Seconds max
+300
( ) See NOTES on page 3.
Page 2
VKA60xs Rev B 4/99
NOTES:
(1) See Typical Performance Curves, page 3
ORDERING INFORMATION
VKA60 xSzz -
(2) Continuous Mode
Device Family
(3) See graphs for Efficiency vs. Output Load, VIN, TCASE
(4) 3.3V Models Limited in Trim Down Range
(5) Consult Factory for Details
Indicates 60 Watt Regulated Unit
Model Number
Selected from Table of Electrical Characteristics
Where:
x = Input Voltage (L = 24VDC; M = 48VDC)
zz = Output Voltage (03=3.3V, 05=5V, etc.)
Lead Length
0.200" - No Number
0.145" - (6)
0.110" - (8)
Remote On-Off Logic:
Positive - No Number
Negative - (1)
TYPICAL PERFORMANCE CURVES
TA = +40°C, nominal input voltage, rated load, recommended external components applied, unless otherwise specified.
EFFICIENCY vs OUTPUT LOAD
EFFICIENCY vs OUTPUT LOAD
95
90
95
90
EFFICIENCY vs TEMPERATURE
28V
24V
15V
+10
+5
12V
5V
85
80
85
80
3.3V
15V
24V
TYP
100% Load
20% Load
28V
-5
75
70
75
70
-10
20
40
60
80
100
20
40
60
80
100
0
0
-55
-15
+25
+65
+105
Output Load (% of Rated)
Output Load (% of Rated)
Tcase (°C)
EFFICIENCY vs INPUT VOLTAGE
OUTPUT RIPPLE vs INPUT VOLTAGE
OUTPUT RIPPLE vs TEMPERATURE
3.0
2.0
1.0
+10
+5
1.50
1.25
1.00
0.75
0.50
TYP
-5
100% Load
50% Load
0.5
10% Load
0.33
-10
Vin, min
-15
+25
+65
+105
Vin, typ
Vin, max
Vin, min
Vin, typ
Vin, max
-55
Tcase (°C)
Vin (VDC)
Vin (VDC)
REFLECTED RIPPLE CURRENT
vsTEMPERATURE
+100
POWER DERATING WITH NO HEATSINK
+50
TYP
-50
22
20
18
16
14
12
400 LFM
200
LFM
-100
10
8
-15
+25
+65
+105
-55
Tcase (°C)
Natural
Convection
6
4
2
0
0
25
50
75
100
Ambient Temperature (°C)
VKA60xS Rev B 4/99
Page 3
MECHANICAL
NOTES:
All dimensions are in inches (millimeters).
PIN PLACEMENT TOLERANCE: 0.005"
MECHANICAL TOLERANCE: 0.015"
0.530 MAX
[13.46]
Marked with: specific modeL ordered, date code, job
code.
0.20 [5.1]
MATERIAL: Units are encapsulated in a low thermal
resistance molding compound which has excellent
chemical resistance and electrical properties in high
humidity environments and over a wide operating
temperature range. The encapsulant and outer shell of
the unit have UL94V-0 ratings. Lead material is solder
plated to allow ease of solderability.
.040 [1.02] DIA.
7 PLACES
.081 [2.06] DIA.
2 PLACES
0.20 [5.1]
0.50 [12.7]
.400 [10.16]
0.40 [10.16]
2.000
[50.80]
0.700
[17.78]
1.000
[25.40]
1.000
[25.40]
2.40
[61.0]
MAX
1.400
1.400
[35.56]
[35.56]
MOUNTING INSERTS M3 X 0.5 THRU, 4 PLACES
MAX. TORQUE, 8 IN/LBS
1.900
0.19 [4.8]
[48.26]
2.28
[57.91]
MAX
OUTPUT VOLTAGE ADJUST
OVP NOTE
This feature allows the user to accurately adjust the
module's output voltage set point to a specified level.
This is achieved by connecting a resistor or potentiometer
from the TRIM terminal to either the +Vout terminal (for
increased Vout) or the -Vout terminal (for decreased
Vout). The formulae below describe the trim resistor
value to obtain a Vout change of ∆%. VO is output
voltage prior to adjustment (3.3V, 5V, 12V, 15V, 24V or
28V).
Special attention should be given to the peak voltage
deviation during a dynamic load step when trimming the
output above the original set point to avoid tripping the
overvoltage protection circuit. Should an OVP condition
occur, the converter will go into a latch condition and
must be externally reset before it will return to normal
operation.
Vo(100 + ∆%)
1.225∆%
(100 + 2∆%)
∆%
_
Radj - up =
kΩ
(
)
100
∆%
Radj - down =
(
- 2
)
kΩ
Page 4
VKA60xs Rev B 4/99
相关型号:
VKA60MS05-1C
DC-DC Regulated Power Supply Module, 1 Output, 60W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-9
MURATA
VKA60MS05-61C
DC-DC Regulated Power Supply Module, 1 Output, 60W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-9
MURATA
VKA60MS05-6C
DC-DC Regulated Power Supply Module, 1 Output, 60W, Hybrid, ROHS COMPLIANT, HALF BRICK PACKAGE-9
MURATA
©2020 ICPDF网 联系我们和版权申明