VO85516A-B200A [ETC]
KOMPAKTVENTIL HIGH FLOW MAGNET FEDER ; KOMPAKTVENTIL高流量磁铁FEDER\n型号: | VO85516A-B200A |
厂家: | ETC |
描述: | KOMPAKTVENTIL HIGH FLOW MAGNET FEDER
|
文件: | 总6页 (文件大小:183K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Nugget 40
V08 Series
Integrally Ported 5/2 and 5/3 Spool Valves
Solenoid Actuated and Pilot Operated
Ø 4, Ø 6mm or M5
● High flow from 17 mm body width
● Low power solenoids with a range of voltages
● Use valves singly or with Base Systems
● Low profile fixed length manifolds
● Modular manifolds can be DIN rail or surface mounted
Technical Data
Ordering Information
To order, quote model number and voltage code
from tables overleaf, e.g. V085516A–B213A for a
Solenoid Pilot Actuated, Spring and Air Return
model fitted with a 24 V d.c. coil and screwdriver
operated manual override.
Medium:
Compressed air, filtered to 40µm lubricated and non-lubricated
Operation:
Spool valve, indirectly actuated
Mounting:
Through-holes in valve body or to 35 mm DIN rail using modular
base system
Multipole Systems
For complete Valve Islands see section 5.4.112
Port Sizes:
5/2
M5, Ø 4 mm and Ø 6 mm (with connector blocks)
Operating Pressure:
Maximum 10 bar
See individual details overleaf
5/2 Twin Supply
Flow Characteristics:
Size
M5
Ø 4mm 5/2
Ø 6mm 5/2
Function ‘C’
‘b’
‘A’
l/min Cv
Kv
5/3
5/2
1
0,9
1,4
0,55
0,54
0,42
4,23
3,74
5,7
256
226
344
296
0,26 0,22
0,23 0,2
0,35 0,3
All ports blocked mid
position
M5
5/3 APB 1,22 0,32
4,89
0,3
0,26
5/3
Centre open exhaust
mid position
Ambient Temperature:
-20˚C to +80˚C Pilot Models
-20˚C to +50˚C Solenoid Models
5/3 Centre open
pressure mid position
Consult our Technical Service for use below +2˚C
*
Materials
Zinc alloy body, glass filled end caps, aluminium spool with
bonded nitrile rubber seals, and glass filled co-polymer bases.
2
14
4
12
5
1
3
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
02/97
N/** 5.4.105.01
Nugget 40, V08 Series
General Information
5/2 Solenoid Actuated Valves
Symbol
Model
Manual
Overide
Solenoid
Pilot
Operator
Solenoid
Solenoid
Return
Operating
Pressure (bar)
Pilot
Pressure (bar)
Weight
(kg)
Spares kit
4
2
V085516A–B21*A
V085516A–B31*A
V085511A–B21*A
V085511A–B31*A
Screwdriver Bi-stable
Push Only
14
12
12
Internal
Internal
Spring and Air
Solenoid
3 – 10
2 – 10
–
–
0,155
0,198
V10034–K00
V10034–K00
5
1
3
4
2
Screwdriver Bi-stable
Push Only
14
5
1
3
*Insert voltage code from table below.
5/3 Solenoid Actuated Valves
Symbol
Model
Manual
Overide
Pilot
Supply
Operator
Mid
Position
Return
Operating
Pressure (bar)
Pilot
Pressure (bar)
Weight
(kg)
Spares kit
4
4
4
2
2
2
14
84
12
82
V085611A–B21*A
V085611A–B31*A
Screwdriver Bi-stable
Push Button
Internal
Internal
Internal
Solenoid
Solenoid
Solenoid
APB
Solenoid
Solenoid
Solenoid
-0,9 – 10
–
–
–
0,158
V10034–K01
V10034–K02
V10034–K03
5
5
1
1
1
3
3
3
14
84
12
82
V085711A–B21*A
V085711A–B31*A
Screwdriver Bi-stable
Push Button
COE
COP
-0,9 – 10
-0,9 – 10
0,158
0,158
14
84
12
82
V085811A–B21*A
V085811A–B31*A
Screwdriver Bi-stable
Push Button
5
*Insert voltage code from table below.
Pilot Actuated Valves
Symbol
Model
Manual
Operator
Mid-
Return
Operating
Pilot
Weight
Spares kit
Override
Position
Pressure (bar)
Pressure (bar)
(kg)
4
2
1,5 + 0,5
x supply
14
12
V085536A–X0130
V085533A–X0020
V085633A–X0020
V085733A-X0020
V085833A-X0020
V085533A-X0060
–
–
–
–
–
–
Pressure
-
Spring and Air
Pressure
2 - 10
0,152
V10034-K00
V10034-K00
V10034-K01
V10034-K02
V10034-K03
V10034-K00
5
1
1
3
4
2
14
12
Pressure
Pressure
Pressure
Pressure
Pilot Priority
-
1 - 10
1 - 10
1 - 10
1 - 10
-0,9 - 10
2 - 10
0,141
0,119
0,119
0,119
0,119
5
3
4
2
Minimum
2 bar
APB
COE
COP
–
Spring and Air
Spring and Air
Spring and Air
Pilot
14
12
12
12
5
1
3
4
2
Minimum
2 bar
14
5
1
3
4
2
Minimum
2 bar
14
1
3
5
4
2
Minimum
2 bar
14
12
5
3
1
APB = All Ports Blocked, COE = Centre Open Exhaust, COP = Centre Open Pressure.
*Voltage Codes and Spare Coils
Electrical Details for Solenoid Operators
Voltage
Codes
Power Inrush/Hold
1,5 W
Coil Part Number
V10025-A11
V10025-A12
V10025-A13
V10025-A11
V10025-A14
V10025-A16
V10025-A18
V10025-A19
Voltage Tolerances:
Rating:
±10%
6V d.c.
1
2
3
1
4
6
8
9
100% E.D.
0,8 mm
12V d.c.
1,7 W
Inlet Orifice:
24V d.c.
1,7 W
Electrical Connection:
Manual Override:
DIN 43650 table ‘C’
12V 50/60Hz
24V 50/60Hz
48V 50/60Hz
110V 50/60Hz
240V 50/60Hz
4,1/2,9 VA
4,1/2,9 VA
4,1/2,9 VA
3,5/2,5 VA
3,5/2,5 VA
V0855--A–B21*A – Screwdriver Bi-stable
V0855--A–B31*A – Push button, spring return
Protection Class:
IP 65 (DIN 40050)
For details of connector plugs and light emitting seals see section 7.7.001.
Accessories
Optional Port Connector Blocks
V085516A–Q0404, Ø4 mm
V085516A–Q0404, Ø6 mm
Blanking Plate
Optional Tie Rod Kits
DIN Rail
Blanking Plug
V10511–K01
–
VO95516A–Q1100
–
V085516A–Q0302–0316
–
V10009–C00 1 metre
–
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/** 5.4.105.02
02/97
Nugget 40, V08 Series
V085516A Models
5/2 Single Solenoid Valve
V085511A Models
5/2 Double Solenoid Valve
156
12
109
65
65
12
Ø2,5
Ø2,5
‘14’
‘12’
‘14’
‘12’
‘5’
‘1’ ‘3’
‘5’
‘1’
24
‘3’
M5 x 0,8
71
M5 x 0,8
24
71
142
12
101
65
65
12
M5 x 0,8
M5 x 0,8
‘4’
‘4’
‘2’
Ø2,7
6
‘2’
Ø2,7
6
Manual
Override
Manual
Override
Manual
Override
63,25
16,5
63,25
16,5
V085*11A-B21*A Model
5/3 Double Solenoid Valve
171
Manual Override
'14'
M5x0,8
71
'12'
'5' '1' '3'
24
157
12
65
M5x0,8
6
63,25
16,5
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
02/97
UK/** 5.4.105.03
Nugget 40, V08 Series
V085536A–X0130 Model
5/2 Single Pilot Valve
V085533A–X0020 and V085533A–X0060
5/2 Double Pilot Valves
23,5
12
23,5
12
M5x0.8
M5x0.8
Ø2,5
Ø2,5
14
12
14
12
5
1
3
5
1
3
M5
M5
8,5
8,5
24
60,5
12
24
61,5
12
30
30
24
24
M5
M5
4
4
2
2
Ø2,7
Ø2,7
6
6
21,8
22,5
16,5
16,5
V085*33A-X0020 Model
5/3 Double Pilot Valve
M5x0.8
'14'
'12'
'5' '1' '3'
8,5
M5x0,8
24
30
75
24
12
M5x0,8
4
2
6
16,5
36,5
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
N/** 5.4.105.04
02/97
Nugget 40 V08 Series
Modular Manifold for DIN rail or surface mounting
156
Manifold Block (A)
Position indicators
V085516A–Q01A8
Single Station Manifold Block
‘C’
End Plate Kit (B)
V085516A–Q02A8
‘12’
‘14’
Consisting of 1 left hand and 1 right hand end cap with
push-in connectors and DIN rail mounting system
Size: Ø 8 mm tube
‘3/5’ ‘1’
62
45
45
Optional Port Connector Blocks (C)
Push-in port connector block with integral position
indicators
‘B’
‘3/5’
‘1’
V085516A–Q0404
V085516A–Q0406
Size: Ø 4 mm tube
Size: Ø 6 mm tube
‘4’
‘4’
‘4’
‘2’
Tie Rod Kits
‘2’
‘2’
V085516A–Q03**
** = Number of stations in manifold, 02 to 16.
Pillar screws supplied as standard with Manifold Blocks
and End Plate kits. Tie Rod Kits are an optional extra.
‘A’
‘B’
‘4’
‘2’
‘1’
‘3/5’
23
8
16
N = Number of stations
Modular Manifold assemblies for DIN rail or surface mounting
Modular Manifold Assemblies
V088AX**–XXXXX
3/5
1
Manifold assemblies for 2 to 16 stations, ** = 02 to 16.
Size: Ø 8 mm tube
Right hand end
62
45
Dual Pressure Modular Manifold assemblies
V088AX**–**XXX
Manifold assemblies for 2 to 16 stations, allows supply of
two different inlet pressures simultaneously
Size: Ø 8 mm tube
** = 1 to 15 to indicate position of Dual Pressure Plug, e.g
V088AX03–07XX indicates a 10 station base divided into
groups of 3 and 7.
Dual Pressure Plug
V085516A–Q05AA
To be placed in the inlet gallery
***
Left hand end
23
16
15
N = Number of stations
*** For 8 mm tube
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
02/97
UK/** 5.4.105.05
Nugget 40 V08 Series
Type
No. of stations
A
Fixed Length Manifold
V10026 – G02
V10026 – G04
V10026 – G06
V10026 – G08
V10026 – G10
V10026 – G12
2
58
A
G1
8
/
4
94
6
130
166
202
238
5
5
8
10
12
Note: Gaskets and valve fixing screws are supplied with
these manifolds.
18.5
18
21,5
9
17,5
Blanking Plugs
V10511-K01
For dual pressure supply on Fixed Length Manifold.
14
Blanking Plate
38
27,5
V095516A–Q1100
Blanking Plate for blocking off unwanted stations.
11
M2,5
Accessories
Connector plugs and light emitting seals see section 7.7.001.
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can
exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider
the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to
equipment in the event of such failure.
System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.
Our policy is one of continued research and development. We therefore reserve the right to amend,
N/** 5.4.105.06
02/97
without notice, the specifications given in this document.