PDF下载Ene rg y Ma na g e m e nt
Pow e r Ana lyze r w ith p lug -in O utp ut Mod ule s
Typ e W M2 2 -DIN
• Class 0.5 (current/voltage)
• Three-phase power analyzer
• Back-lighted LCD
• 4 x 31/2 DGT instantaneous variables read out
• 71/2 DGT energy read-out
• Measurements of system and phase variables:
W, Wdmd, var, VA, VAdmd, PF (cosϕ), V, A, Hz, THD-A, THD-V
• Measurements of total energies: kWh, kvarh
• Measurements of partial energies: kWh, kvarh
• Energy measurements according to EN61036 and EN61268
• TRMS measurements of distorted wave forms
(voltages/currents)
• Two basic models: direct connection 20(90)AAC,
CT 5(10)AAC and VT connection
• Front dimensions: 9 DIN modules
• Maximum value indication of W dmd and VA dmd (only
5A version); maximum value indication of A (only 90A
version)
• Self power supply (available for some models only) or
auxiliary power supply: 24V, 48V, 115V, 230V, 50-60Hz;
18 to 60VDC, 77 to 143VDC
• Analogue output by means of optional module
(20mA or 10VDC)
• RS 422/485 Serial port by means of optional module
• Alarm output by means of optional module
• Dual pulse output by means of optional module
• Control of phase asymmetry
• Degree of protection (front): IP 40
Pro d uct d e scrip tio n
How to order
W M2 2 -DIN AV5 3 X X XX
tion area from 6 to 35 mm2.
The special design of the
Model
Range code
instrument’s housing allows System
Three-phase power analyzer
with built-in configuration
key-pad;
Particularly indicated for the
analysis of main, secondary
and energy metering electri-
cal variables.
to add at any time the inter-
face modules, even when
the instrument is already
installed.
Power supply
Slot A
Slot B
Housing for DIN-rail or wall-
mounting, IP40 (front) pro-
tection degree.
Completely sealable housing.
In case of direct connection
up to 90A, the measuring
input terminals are suitable
for cables with a cross-sec-
The following modules are Important note:
available:
- for all versions: pulses out-
put;
• The models from AV0 to AV7 can be equipped with any
type of available modules (slot A and B).
• The models AV8 and AV9 can be equipped only with the
“O” and “R” type modules.
- only for the versions with
auxiliary power supply: • The AV8 and AV9 models can measure all the parameters even if
analogue output, RS485
port or alarm output.
the three phase system being connected is missing one phase.
• The Av2 model is suitable only for three-phase unbalanced sys-
tem without neutral.
Typ e se le ctio n
Range Code
Power supply
Slot A (retransmission)
Slot B (retransmission)
Auxiliary Power Supply:
For all versions
X:
O:
None
Only with A-B-C-D-4
power supply
AV0: 208VL-L/20(90)AAC [3]
AV1: 400VL-L/20(90)AAC [1]
AV3: 660VL-L/20(90)AAC [2]
AV4: 208VL-L/5(10)AAC [3]
AV5: 400VL-L/5(10)AAC [1]
AV6: 100VL-L/5(10)AAC [3]
AV7: 660VL-L/5(10)AAC [2]
Self Power Supply:
AO2900 module
Dual open collector out-
put
A:
B:
C:
D:
24VAC
-15+10%, 50-60Hz
48VAC
-15+10% , 50-60Hz
115VAC
-15+10% , 50-60Hz
230VAC
XX:
A1:
None
AO2920 module
0-20mADC
Three operating modes:
analogue output
AO2921 module
0-10VDC
analogue output
AR2950 module
RS422/485
• two pulse outputs
(kWh and kvarh);
• one alarm output
and one pulse
output (kWh or kvarh)
• one output which is
remotely controlled
by a serial port
V1:
S0:
-15+10% , 50-60Hz
18 to 60VDC
77 to 143VDC
AV2: 220VL-L/20(90)AAC [4]
AV8: 208VL-L/20(90)AAC [1]
AV9: 400VL-L/20(90)AAC [1]
4:
5:
AV2, AV8 and AV9 only
serial port
X:
Self Power Supply
and one pulse
output (kWh or kvarh)
System
400V
L-L
(-20+15% , 50-60Hz)
R:
AO2910 module.
3 :
Three-phase,
unbalanced load with
or without neutral
208V
L-L
One relay output + one
open collector output.
Operation modes like
module AO2900.
(-20+15% , 50-60Hz)
220V
L-L
(-10+15% , 50-60Hz)
[1] Un: -20+15% [2] Un: -30+15% [3] Un: -20+20% [4] Un: -10 +15%
Specifications are subject to change without notice WM22-DINDS1003
1
WM22-DIN
In p ut sp e cifica tio ns
Number of inputs
Current
Voltage
Additional errors
Wave form
Voltage asymmetry
Magnetic induction
HF Electromagnetic fields
Operation of accessories
Acc. to EN61036, EN61268
<1% (3rd harmonic: 10%)
< 0.5% (referred to Un)
0 (up to 0.5 mT)
< 1%
3
4
Accuracy (display, RS485)
Ib: 5A, Imax: 10A
Ib: 20A, Imax:90A
0
Un: see previous page
“Range code”
from 0.003Ib to 0.2Ib:
±(0.5%RDG +3DGT)
from 0.2Ib to Imax:
±(0.5%RDG +1DGT)
Temperature drift
Sampling rate
Display
≤ 200ppm/°C
Current
1000 samplings/s @ 50Hz
Type
Back-lighted LCD
Instantan. variables read-out
Energies
4x31/
2
DGT
Total:1x71/
Partial: 1x71/
Voltage
in the range Un:
±(0,5% RDG + 1DGT)
±0.1% RDG (50 to 60 Hz)
2
DGT
DGT
2
Frequency
Max. and Min. indication
Measurements
Max. 1999 (19999999), Min. 0
Active power
Current, voltage, power,
energy, power factor, frequen-
cy, harmonic distortion (see
display specs). TRMS
measurements of distorted
wave forms.
(@ 25°C ± 5°C, R.H. ≤ 90%) ±(1% RDG +1DGT). PF 1,
0.1Ib to Imax, in the Un range;
PF 0.5L, PF 0.8C, 0.2Ib to
Imax, in the Un range
Reactive power
(@ 25°C ± 5°C, R.H. ≤ 90%) ±(2% RDG +1DGT). sinϕ 1,
0.05Ib to Imax, in the Un range;
sinϕ 0.5L, sinϕ 0.5C,
0.1Ib to Imax, in the Un range
Apparent power
(@ 25°C ± 5°C, R.H. ≤ 90%) ±(1% RDG +1DGT). PF 1,
0.1Ib to Imax, in the Un range
Energies
(@ 25°C ± 5°C, R.H. ≤ 90%) Class 1 acc. to EN61036
Class 2 acc. to EN61268
Coupling type
Direct
Crest factor
Ib 5A
Ib 20A
≤3 (15A max. peak)
≤6 (127A max. peak)
Current overload
5(10) A, for 10ms
5(10) A, for 500ms
5(10) A, permanent
20(90) A, for 10ms
20(90) A, permanent
300 A max, @ 50Hz
200 A max, @ 50Hz
10A, @ 50Hz
2700A max, @ 50Hz
90A, @ 50Hz
Ib: 5A, Imax: 10A
0.1Ib: 500mA,
Start up corrent: 20mA
Un: see table “range code”
Ib: 20A, Imax: 90A
Voltage overload
Permanent
For 1s
1.2 Un
2 Un
0.1Ib: 2A,
Start up current: 80mA
Input impedance
Un: see table “range code”
400VL-L (AV1-AV5-AV9)
208VL-L (AV0-AV4-AV8-AV2)
660VL-L (AV3-AV7)
100VL-L (AV6)
5(10) A (AV4-AV5-AV6-AV7)
> 720KΩ
> 720KΩ
> 1.97MΩ
> 400KΩ
< 0.3VA
Harmonic distortion
±3% f.s. (f.s.: 100%)
(@ 25°C ± 5°C, R.H. ≤ 90%) up to the 7th harmonic;
Un: see table “range code”
Ib 5A
Imin: 500mA;
Imax: 15Ap;
Imin: 2A;
20(90) A (AV0-AV1-AV3-AV8-AV9) < 4VA
20(90) A (AV2)
Ib 20A
< 4VA
Imax: 127Ap;
Frequency
50 to 60 Hz
In te rfa ce m o d ule sp e cifica tio ns
Analogue outputs (on request)
the following ranges:
Number of outputs
Range
1
0 and 20mADC, 0 and 10VDC
0 to 20 mADC
Response time
System variables
FFT off, filter off
FFT on, filter on
variables
(AO2920 module slot B,
only for versions with
auxiliary power supply)
0 to 10VDC
(AO2921 module slot B,
only for versions with
auxiliary power supply)
±0.5% F.S.
≤ 300 ppm/ °C
Programmable within the
whole range of
retransmission;
it allows the retransmission
of all the values included in
V, W, VA, var, PF (cosϕ)
900ms
1.4s
THD-V, THD-A
3s
Filter off
Ripple
≤1% according to IEC 60688-1,
EN 60688-1
Accuracy
Temperature drift
Scaling factor
Load
20 mADC
10 VDC
Insulation
≤ 500 Ω
≥ 10 kΩ
By means of optocouplers,
2000 VRMS between output
and measuring input
2
Specifications are subject to change without notice WM22-DINDS1003
WM22-DIN
Inte rfa ce m o d ule sp e cifica tio ns (co n t.)
2000 V between output
and power supply input
RMS
According to DIN43864
By means of optocouplers,
Insulation
RS422/RS485 (on request)
AR2950 module
2000 V outputs to
RMS
Type
Multidrop
measuring inputs,
bidirectional (static and
and dynamic variables)
2 or 4 wires, max. distance
1200m, termination directly
on the module
2000 V output to
supply input.
Insulation between the two
outputs: functional
RMS
Connections
Alarm output
Addresses
Protocol
Data (bidirectional)
Dynamic (reading only)
255, selectable by key-pad
MODBUS/JBUS
Number of outputs
Alarm type
1
Up alarm, down alarm
phase asymmetry, phase
loss.
0 to 100% of the electrical
scale
0 to 100% of the electrical
scale
0 to 255 seconds
Phase and system variables:
see table “Display pages”
All the programming data,
reset of energy, activation of
static output.
Stored energy (EEPROM)
max. 19.999.999 kWh/kvarh
1 start bit, 8 data bit,
no parity, 1 stop bit
Setpoint adjustment
Hysteresis
Static (writing only )
On-time delay
Response time
system variables
FFT off, filter off
FFT on, filter on
variables
Data format
V, W, VA, var, PF (cosϕ)
700ms
1.2s
THD-V, THD-A
3s
Open collector (transistor NPN)
VON 1.2 VDC / max. 100 mA
VOFF 30 VDC max.
By means of optocouplers,
Baud-rate
Insulation
9600 bit/s
By means of optocouplers,
2000 VRMS output
Filter off
Output type
to measuring inputs
2000 V output to
RMS
supply input
Digital outputs (on request)
Insulation
2000 V output to
measuring input,
RMS
AO2900 module
To be used as alarm, energy
retransmission, or remote
static outputs.
2000 V output to
RMS
supply input.
Insulation between the two
outputs: functional
Relay + open collector
output. Working mode like
AO2900.
One static output+one relay
output, other characteristics
like AO2900.
Only relay output, other
characteristics like AO2900.
Static type like module
AO2900;
Relay type: SPDT,
AC1, AC15: 1AAC @250VAC
By means of optocouplers,
Three working modes are
selectable:
• two pulse outputs
(kWh and kvarh);
• one alarm output and
one pulse output
(kWh or kvarh)
• one output remotely con-
trolled by means of the
serial port and one pulse
output (kWh or kvarh)
AO2910 module
Pulse output
Alarm output
Output type
Pulse outputs
Number of outputs
Number of pulses
2
From 0.01 to 100 pulses
programmable according
to the selected CT and VT
ratios
Open collector (transistor NPN)
VON 1.2 VDC / max. 100 mA
VOFF 30 VDC max.
Insulation
2000 V outputs to
RMS
measuring inputs,
2000 V output to
RMS
Output type
supply input.
Insulation between the two
outputs: 2000 V
RMS
Pulse duration
220 ms (ON), ≥ 220 ms (OFF)
Specifications are subject to change without notice WM22-DINDS1003
3
WM22-DIN
So ftw a re fun ctio ns
Electrical range
Filter
Programmable within the
whole measuring range.
Password
Numeric code of max.
3 digits
2 protection levels of the
programming data
Password “0”, no protection
Password from 1 to 1000,
all data are protected
Filter operating range
0 to 99.9% of the input
electrical scale.
1 to 16
Alarm, analogue and serial
output (fundamental
variables: V, A, W and their
derived ones).
1st level
2nd level
Filter coefficient
Filter action
System selection
Three-phase with neutral
Three-phase without neutral
Transformer ratio
CT
Display
System variables
Up to 4 variables per page
Page 1: W-var-PF (cosϕ)
Page 2: W dmd - VA dmd - Hz
Page 3: THD-V
Page 4: THD-A
Page 5: kWh total
Page 6: kvarh total
Page 7: kWh partial
Page 8: kvarh partial
1 to 5000
VT
1.0 to 199.9 and 200 to 1999
Note:
The CT ratio* VT ratio must
never exceed the value
5000. The current
measuring inputs can
manage CT’s with a
secondary of 1A and 5A
(the accuracy always refer
to 5A)
Single phase variables
System variables
Single phase variables
Page 9: V
L-N
Page 10: A
20(90) A
5(10) A
Page 11a: A MAX
Page 11b: W dmd MAX VA dmd MAX
Page 12: W
Page 13: VA
Page 14: var
Scaling factor
Operating mode
Compression/expansion of
the measuring range to be
connected to the analogue
output.
Page 15: PF (cosϕ)
Sup p ly sp e cifica tio ns
Self supplied version
400V
115VAC
L-L
-20% +15%, 50-60Hz
-15 +10%, 50-60Hz
48VAC
208V
L-L
-20% +15% , 50-60Hz
-15 +10%, 50-60Hz
24VAC
220V
L-L
-10% +15% , 50-60Hz
-15 +10%, 50-60Hz
18 to 60VDC
77 to 143VDC
Auxiliary power supply
230VAC
-15 +10%, 50-60Hz
Energy consumption
Pulse voltage (1.2/50µs)
≤ 7VA
Ge n e ra l Sp e cifica tio ns
Operating
0 to +55°C
8kV (EN61000-4-5)
temperature
(R.H. < 90% non-condensing
40°C)
Standards
Safety
IEC664-1
Storage
temperature
-20 to +60°C
(R.H. < 90% non-condensing
40°C)
Metrology
Energy measurements:
EN61036, EN61268.
DIN43864
Pulse output
Installation category
Insulation
Cat. III (IEC 664)
Approvals
CE
2000 VRMS between all inputs
outputs to earth
/
Connections 5(10) A
Cable cross-section area
Screw-type,
4 mm2
Dielectric strength
4000 VRMS for 1 minute
Connections 20(90) A
Screw-type,
Min./Max. cable cross-section area 6 mm2 / 35 mm2
Min./Max. screws tightening torque 2 Nm / 6 Nm
Noise rejection
CMRR
100 dB, 48 to 62 Hz
Housing
Dimensions
Material
EMC
162.5 x 90 x 63 mm
ABS, NORYL, PC
self-extinguishing: UL 94 V-0
Burst
4kV/level 4 (EN61000-4-4)
Immunity to irradiated
electromagnetic fields
10V/m 26-1000MHz
(EN61000-4-3)
15kV (EN61000-4-2)
according to CISPR 14
and CISPR 22
Mounting
DIN-rail and wall
Degree of protection
Front: IP40
Connections: IP20
800 g approx.
(packing included)
Electrostatic discharges
Radio frequency emissions
Weight
4
Specifications are subject to change without notice WM22-DINDS1003
WM22-DIN
Functio n d e scrip tio n
Input and output scaling capability
Working examples of the analogue output (Y) versus the input variable (x) - (input/output scaling possibilities).
Figure A
Figure B
The sign of measured quantity
and output quantity remains
the same. The output quantity
is proportional to the mea-
sured quantity.
The sign of measured quantity
and output quantity remains
the same. With the measured
quantity being zero, the output
quantity already has the value
Y1 = 0.2 Y2.
Live zero output.
0
4
50 A
100 A
0
0
50 A
100 A
12 mA
20 mA
10 mA
20 mA
Figure C
The sign of measured quantity
and output quantity remains
the same. On the range
X0...X1, the output quantity is
zero. The range X1...X2 is deli-
neated on the entire output
range Y0=Y1...Y2 and thus
presented in strongly expan-
ded form.
80 V
0
100 V
5 mA
120 V
10 mA
Mo d e o f O p e ra tio n
Waveform of the signals that can be measured
Figure D
Figure E
Figure F
Sine wave, undistorted
Fundamental content
Harmonic content
Sine wave, indented
Fundamental content
Harmonic contents
Sine wave, distorted
Fundamental content
Harmonic content
100%
0%
10...100%
0...90%
70...90%
10...30%
A
rms
=
1.1107 | A |
Frequency spectrum: 3rd to the 16th harmonic
Additional error: <1% rdg
Frequency spectrum: 3rd to the 16th harmonic
Additional error: <0.5% rdg
Ha rm o nic d isto rtio n a na lysis
Anaysis principle
FFT
THD (AL2), THD (AL3)
THD %
Read-out
System
Harmonic measurement
Current
Voltage
Up to the 7th harmonic
Up to the 7th harmonic
The harmonic distortion
can be measured in 3-wire
or 4-wire systems.
Type of harmonics
THD (VL1), THD (VL2),
THD (VL3), THD (AL1)
Specifications are subject to change without notice WM22-DINDS1003
5
WM22-DIN
Disp la y p a g e s
Variables that can be displayed
No
1
1st variable
2nd variable
PF sys
Hz
3rd variable
Var sys
4th variable
Notes
W sys
sys = system
2
W dmd
VA dmd
dmd = demand
(integration time from 1 to 30 minutes)
3
V
THD
V
THD
V
THD
THD = tot. harmonic distortion
THD = tot. harmonic distortion
total energy
L1
L2
L3
4
AL1 THD
kWh
AL2 THD
AL3 THD
5
6
kvarh
kWh
total energy
7
partial energy
8
kvarh
partial energy
9
V
L1
V
L2
V
L-3
VL-L sys
sys = system
10
11a
11b
12
13
14
15
AL1
W dmd MAX
AL1 MAX
WL1
AL2
VA dmd MAX
AL2 MAX
WL2
AL3
Err
Err = in case of negative power
Only version 1-5A, dmd = demand
Only version 90A
AL3 MAX
WL3
W sys
VA sys
Var sys
PF sys
sys = system
VAL1
VAL2
VAL3
The system value remains always 0
if the neutral is not connected
VarL1
VarL2
VarL3
PFL3
PFL1
PFL2
Used calculation formulas
Phase variables
System variables
Note:
Instantaneous effective voltage
Equivalent system voltage
System reactive power
System active power
System apparent power
System power factor
i = phase (L1, L2 or L3)
T = variable (V or I)
n = harmonic order
Instantaneous active power
Consumption recording
Instantaneous power factor
(TPF)
Instantaneous effective current
Instantaneous apparent power
Instantaneous reactive power
Note:
i = phase (L1, L2 or L3)
P = active power
Q = reactive power
t1, t2 = starting and ending time points of consumption
recording
n = time unit
∆t = time interval of consumption recording
(TPF)
Total harmonic distortion
n1, n2 = starting and ending discrete time points of consumption
recording
List of the of the va ria b les tha t ca n b e connected to the a na log ue a nd a la rm outp ut
N°
1
2
3
4
Variable
V sys
W sys
var sys
VA sys
PF sys
Notes
N° Variable
Notes
sys = system
sys = system
sys = system
sys = system
sys = system
6
THD-V
THD-A
VA dmd
W dmd
ASY
Max. THD value among the three phases
Max. THD value among the three phases
Power demand in the selected
integration time
7
8
9
5
10
Phase asymmetry
6
Specifications are subject to change without notice WM22-DINDS1003
WM22-DIN
Ava ila b le m o d e ls
Type
Inputs
Power supply
Self power supply
Self power-supply
Self power-supply
230VAC, 50-60Hz
230VAC, 50-60Hz
230VAC, 50-60Hz
115VAC, 50-60Hz
115VAC, 50-60Hz
115VAC, 50-60Hz
48VAC, 50-60Hz
Ordering code
AF2100
WM22-DIN AV9.3.X.
WM22-DIN AV8.3.X.
WM22-DIN AV2.3.D.
WM22-DIN AV1.3.D.
WM22-DIN AV0.3.D.
WM22-DIN AV3.3.D.
WM22-DIN AV1.3.C.
WM22-DIN AV0.3.C.
WM22-DIN AV3.3.C.
WM22-DIN AV1.3.B.
WM22-DIN AV0.3.B.
WM22-DIN AV3.3.B.
WM22-DIN AV1.3.A.
WM22-DIN AV0.3.A.
WM22-DIN AV3.3.A.
WM22-DIN AV5.3.D.
WM22-DIN AV4.3.D.
WM22-DIN AV7.3.D.
WM22-DIN AV5.3.C.
WM22-DIN AV4.3.C.
WM22-DIN AV7.3.C.
WM22-DIN AV5.3.B.
WM22-DIN AV4.3.B.
WM22-DIN AV7.3.B.
WM22-DIN AV5.3.A.
WM22-DIN AV4.3.A.
WM22-DIN AV7.3.A.
WM22-DIN AV6.3.D.
WM22-DIN AV6.3.C.
WM22-DIN AV6.3.B.
WM22-DIN AV6.3.A.
WM22-DIN AV1.3.4 / [5]
WM22-DIN AV0.3.4 / [5]
WM22-DIN AV3.3.4 / [5]
WM22-DIN AV5.3.4 / [5]
WM22-DIN AV4.3.4 / [5]
WM22-DIN AV7.3.4 / [5]
WM22-DIN AV6.3.4 / [5]
400V , 20(90)A
L-L
208V , 20(90)A
AF2101
AF2144
AF2102
AF2103
AF2104
AF2105
AF2106
AF2107
AF2108
AF2109
AF2110
AF2111
AF2112
AF2113
AF2114
AF2115
AF2116
AF2117
AF2118
AF2119
AF2120
AF2121
AF2122
AF2123
AF2124
AF2125
AF2126
AF2127
AF2128
AF2129
L-L
220V , 20(90)A
L-L
400V , 20(90)A
L-L
208V , 20(90)A
L-L
660V , 20(90)A
L-L
400V , 20(90)A
L-L
208V , 20(90)A
L-L
660V , 20(90)A
L-L
400V , 20(90)A
L-L
208V , 20(90)A
48VAC, 50-60Hz
48VAC, 50-60Hz
24VAC, 50-60Hz
24VAC, 50-60Hz
L-L
660V , 20(90)A
L-L
400V , 20(90)A
L-L
208V , 20(90)A
L-L
660V , 20(90)A
24VAC, 50-60Hz
L-L
400V , 5(10)A
230VAC, 50-60Hz
230VAC, 50-60Hz
230VAC, 50-60Hz
115VAC, 50-60Hz
115VAC, 50-60Hz
115VAC, 50-60Hz
48VAC, 50-60Hz
48VAC, 50-60Hz
48VAC, 50-60Hz
24VAC, 50-60Hz
24VAC, 50-60Hz
L-L
208V , 5(10)A
L-L
660V , 5(10)A
L-L
400V , 5(10)A
L-L
208V , 5(10)A
L-L
660V , 5(10)A
L-L
400V , 5(10)A
L-L
208V , 5(10)A
L-L
660V , 5(10)A
L-L
400V , 5(10)A
L-L
208V , 5(10)A
L-L
660V , 5(10)A
24VAC, 50-60Hz
L-L
100V , 5(10)A
230VAC, 50-60Hz
115VAC, 50-60Hz
48VAC, 50-60Hz
L-L
100V , 5(10)A
L-L
100V , 5(10)A
L-L
100V , 5(10)A
24VAC, 50-60Hz
L-L
400V , 20(90)A
18-60VDC [77-143VDC]
18-60VDC [77-143VDC]
18-60VDC [77-143VDC]
18-60VDC [77-143VDC]
18-60VDC [77-143VDC]
18-60VDC [77-143VDC]
18-60VDC [77-143VDC]
AF2130 [AF2137]
AF2131 [AF2138]
AF2132 [AF2139]
AF2133 [AF2140]
AF2134 [AF2141]
AF2135 [AF2142]
AF2136 [AF2143]
L-L
208V , 20(90)A
L-L
660V , 20(90)A
L-L
400V , 5(10)A
L-L
208V , 5(10)A
L-L
660V , 5(10)A
L-L
100V , 5(10)A
L-L
Ava ila b le m o d u le s
Type
Channels
Code
Type
Channels
Code
Open collector output
0-20mADC analogue output
Relay + open c. output
2
1
2
AO2900
AO2920
AO2910
0-10VDC Analogue Output
RS485 Serial Output
1
1
AO2921
AR2950
Possib le m od ule com b ina tions
Power supply
Self p.s.
Auxiliary p.s.
Power supply
Self p.s.
Auxiliary p.s.
Basic unit
Slot A Slot B Slot A Slot B
Basic unit
Slot A Slot B Slot A Slot B
(*)
(*)
Analogue output
RS485 Serial Output
(*) AV2 only
Open collector output
Relay + open c. output
Specifications are subject to change without notice WM22-DINDS1003
7
WM22-DIN
W iring d ia g ra m s
20(90)A model: three-phase unbalanced load
Self-power supply
Fig. 3
Auxiliary power supply
Fig. 2
Auxiliary power supply
AC power supply
Fig. 1
AC power supply
Direct connection (3-phase system+N)
Direct connection (3-phase system)
Direct connection (3-phase system)
20(90)A model:
5(10)A model:
three-phase unbalanced load
three-phase unbalanced load
Self-power supply
Fig. 4
Auxiliary power supply
Fig. 5
Auxiliary power supply
Fig. 6
AC power supply
AC power supply
Direct connection (3-phase system
with or without neutral)
Direct connection (3-phase system + N)
CT connection (3-phase system+N)
5(10)A model: three-phase unbalanced load
Auxiliary power supply
Fig. 7
Auxiliary power supply
AC power supply
Fig. 9
Auxiliary power supply
Fig. 8
AC power supply
AC power supply
CT ARON connection (3-phase system)
VT and CT ARON connection (3-phase system)
VT and CT connection (3-phase system + N)
8
Specifications are subject to change without notice WM22-DINDS1003
WM22-DIN
W iring d ia g ra m s (o p tio na l m o d ule s)
Open collector output
Fig.10
Relay + open collector output Fig. 11
VDC max 30V
Only open collector outputs: the grounds of the outputs are separated, and therefore it’s possible to carry out, for the same
module, two different connections. The load resistance (Rc) must be designed so that the closed contact current is lower than
100mA; the VDC voltage must be lower than or equal to 30V. VDC: power supply voltage output. Vo+: positive output contact
(open collector transistor). GND: ground output contact (open collector transistor).
RS485 Serial output
Fig. 13
RS485 Serial output
Fig. 14
Analogue output
Fig. 12
Current and voltage
4-wire connection
2-wire connection
Fro n t p a ne l d e scrip tio n
4
3
Keys for:
- value programming;
- function selection;
- displaying the measuring pages.
2
1
2. Display
LCD with alphanumeric indications to:
- display configuration parameters;
- display all the measured variables.
3. Removable label
Label to write the instrument ID number.
1. Key-pad
To program configuration parameters and to display variables.
4. Hidden dip-switch
Enable/ disable the access to the
programming procedure.
S-key to enter programming and confirm selections;
Specifications are subject to change without notice WM22-DINDS1003
9
WM22-DIN
Dim e nsio n s a n d p a ne l cut-o ut
Te rm in a l b o a rd s
Analogue output module
Dual output
open collector module
Relay output module +
open collector output
RS485
serial output module
AO 2920: 0-20 mA
AO 2921: 0-10 V
AO 2900
AO 2910
AR 2950
10
Specifications are subject to change without notice WM22-DINDS1003
WM22-DINAV1COA1 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
WM22-DINAV1CXA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 | |
WM22-DINAV1DOA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 | |
WM22-DINAV1DXA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 | |
WM22-DINAV2AOA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 | |
WM22-DINAV2AXA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 | |
WM22-DINAV2BOA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 | |
WM22-DINAV2BXA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 | |
WM22-DINAV2COA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 | |
WM22-DINAV2CXA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 | |
WM22-DINAV2DOA1 | ETC | Energy Management Power Analyzer with plug-in Output Modules | 获取价格 |
WM22-DINAV1COA1 相关文章
- 2024-09-20
- 6
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6