FTR-H1AA048T [FUJITSU]
POWER RELAY 1 POLE-10 A LOW PROFILE TYPE; 功率继电器1 POLE - 10低调TYPE型号: | FTR-H1AA048T |
厂家: | FUJITSU |
描述: | POWER RELAY 1 POLE-10 A LOW PROFILE TYPE |
文件: | 总8页 (文件大小:693K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
POWER RELAY
1 POLE—10 A LOW PROFILE TYPE
FTR-H1 SERIES
RoHS compliant
n FEATURES
l Working class: B (for IMQ)/ C (for VDE)
l Type of service: continuous duty
l Low profile (height 16.5 mm)/ cadmium free contacts
l 1 form A/ 1 form C 10 A, TV-5 rating available
l UL class B (130°C) insulation
l High isolation in small package (between coil and con-
tacts)
—Insulation distance : 8 mm
—Dielectric strength : 5,000 VAC
—Surge strength
l Plastic materials
UL CTI level class 2
l Plastic sealed relay
:10,000 V
—UL94 flame class V-0
l Pin configuration compatible to VS/ FBR610 Series
l UL, CSA, BSI, VDE, SEMKO recognized
l Conforms to FIMKO, DEMKO
l Environmentally friendly cadmium free contacts type are
available
l RoHS compliant since date code: 0434R
Please see page 7 for more information
n ORDERING INFORMATION
FTR-H1
A
A
005
V
– **
(f)
[Example]
(a)
(b) (c) (d) (e)
(a)
(b)
Series Name
FTR-H1: FTR-H1 Series
Contact Arrangement
A
C
: 1 form A (SPST-NO)
: 1 form C (SPDT)
(c)
(d)
Coil Type
A
D
: Standard type (0.53 W)
: High sensitive type (0.4W)
Nominal Voltage
005
006
009
: 5 VDC
: 6 VDC
: 9 VDC
012
024
048
: 12 VDC
: 24 VDC
: 48 VDC
(e)
Contact Material/TV Type
V
T
: Gold plate silver alloy (standard type)
: Gold plate silver alloy (TV-5 rating type, 1 form A standard type
only)
(f)
Custom Designation
Custom specificationto be assigned
Actual Marking
H1AA005V
Ordering Code
FTR-H1AA005V
1
FTR-H1 SERIES
n SAFETY STANDARD AND FILE NUMBERS
UL508, 873 (File No. E63614)
C22.2 No. 14 (File No. LR40304-30/LR107822)
VDE 0435, 0631, 0700, 0860 (File No. 11039-4940-1019)
Nominal voltage
Contact rating
TV-Rating
General
5 ~ 48 VDC
TV-5 120 VAC
1/2 HP 250 VAC 1/3 HP 125 VAC
10 A 30 VDC/250 VAC resistive
Pilot duty B 300, Q 300
1/2 HP 250 VAC 1/3 HP 125 VAC
10 A 30 VDC/250 VAC resistive
3A 250 VAC inductive (PF=0.4)
Pilot duty B 300, Q 300
2
FTR-H1 SERIES
n SPECIFICATIONS
Item
Standard Type
Sensitive
TV-5 Rating Type
Contact
Arrangement
1 form A (SPST-NO), 1 form C (SPDT)
Gold plate silver alloy
Single
1 form A (SPST-NO)
Material
Style
Ω
(at 1 A 6 VDC)
Resistance (initial)
Rating (Resistive)
Maximum Carrying Current
Maximum Switching Rating
Maximum 100 m
10 A 250 VAC/30 VDC
14 A
2,500 VA/300 W
Maximum Switching Voltage 400 VAC 300 VDC
Maximum Switching Current 10 A
Minimum Switching Load*1
Maximum Inrush Current
Operating Range
10 mA 5 VDC
—
78 A 120 VAC (at lamp load)
Coil
80 to 110 % × V nominal
0.53 W
Nominal Power (at 20°C)
Operate Power (at 20°C)
Operating Temperature
0.4W
0.53 W
0.26W
0.26 W
0.225W
–40°C to +75°C (no frost) (refer to the CHARACTERISTIC DATA)
Time Value Operate (at nominal voltage) Maximum 10 ms
Release (at nominal voltage) Maximum 5 ms
Ω
Minimum 1,000 M
Insulation
Resistance (at 500 VDC)
Dielectric Between open contacts
1,000 VAC 1 minute
Strength
2
Between coil and contacts
*
5,000 VAC 1 minute
Surge Strength*3
10,000 V (at 1.2 x 50 µs)
2 × 107 operations minimum
Life
Mechanical
Electrical
Contact Rating 1 × 105 operations minimum
2.5 x 104 ops. minimum
Lamp Load
Misoperation
Endurance
Misoperation
Endurance
—
Other
Vibration
10 to 55 Hz (double amplitude of 1.65 mm)
10 to 55 Hz (double amplitude of 3.3 mm)
100 m/s 2 (11 ±1 ms)
Resistance
Shock
Resistance
1,000 m/s 2 (6 ±1 ms)
Weight
Approximately 12 g
1
*
Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load
before production since reference values may vary according to switching frequencies, environmental conditions and ex-
pected reliability levels.
IMQ
IMQ
2
*
*
3
3
FTR-H1 SERIES
n COIL DATA CHART
MODEL
Nominal
Voltage
Coil Resistance Must Operate Must Release
(±10%)
Voltage
Voltage
Standard Type
TV-5 Rating Type
FTR-H1 (C, A) A005 V
FTR-H1 (C, A) A006V
FTR-H1 (C, A) A009 V
FTR-H1 (C, A) A012 V
FTR-H1 (C, A) A024 V
FTR-H1 (C, A) A048 V
FTR-H1AA005 T
FTR-H1AA006 T
FTR-H1AA009 T
FTR-H1AA012 T
FTR-H1AA024 T
FTR-H1AA048 T
5 VDC
6 VDC
47 Ω
68 Ω
3.5 VDC
4.2 VDC
6.3 VDC
8.4 VDC
16.8 VDC
33.6 VDC
0.5 VDC
0.6 VDC
0.9 VDC
1.2 VDC
2.4 VDC
4.8 VDC
9 VDC
155 Ω
12 VDC
24 VDC
48 VDC
270 Ω
1,100 Ω
4,400 Ω
Note: All values in the table are measured at 20°C.
Sensitive Type
MODEL
Nominal
Voltage
Coil Resistance Must Operate Must Release
(±10%)
Voltage
Voltage
Standard Type
FTR-H1 (C, A) D005 V
FTR-H1 (C, A) D006 V
FTR-H1 (C, A) D009V
FTR-H1 (C, A) D012 V
FTR-H1 (C, A) D024 V
FTR-H1 (C, A) D048 V
5 VDC
6 VDC
62 Ω
90 Ω
3.75 VDC
4.5 VDC
0.5 VDC
0.6 VDC
0.9 VDC
1.2 VDC
2.4 VDC
4.8 VDC
9 VDC
202 Ω
6.75 VDC
9.0 VDC
12 VDC
24 VDC
48 VDC
360 Ω
1,440 Ω
5,760 Ω
18.0 VDC
36.0 VDC
Note: All values in the table are measured at 20°C.
4
FTR-H1 SERIES
n CHARACTERISTIC DATA
Timing
Coil temperature rise
Timing
20
16
100
20
80
14A
15
10A
12
8
60
10
Operate
Operate
40
0A
5
4
0
20
Release
0.4
Release
0
0.6
0.8
1.0
1.2
0.2
0.6
0.8
1.0
1.2
0.2
0.4
0
0.2
0.4
0.6
0.8
1.2
1.0
Coil power (W)
Coil power (W)
Coil power (W)
Operating range
Operating range
Maximum Switching Power
20
10
5
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
FTR- ( ) A
FTR-H1
FTR- ( ) D
AC Resistive
0 A
0 A
10 A
10 A
2
1
DC Resistive
0.5
0.2
Must operate voltage (hot coil)
Must operate voltage (cool coil)
0
20
40
60
80
100
0
20
40
60
80
100
10
20
50
100 200
500
Ambient temperature (°C)
Ambient temperature (°C)
Contact Voltage (V)
Life Curve
100
50
AC250 V
DC30 V
FTR-H1
AC250V COS ø=0.7
DC30 V t=7ms
20
10
5
AC250V COS ø=0.4
DC30 V t=15ms
0
4
6
8
10
2
12
Contact load current (A)
5
FTR-H1 SERIES
n REFERENCE DATA
Distribution of contact resistance
Distribution of operate and release time
Distribution of operate and release voltage
100
100
100
Operate
Release
Operate
Make
80
60
40
20
80
Release
80
60
40
20
Break
60
40
20
0
1
2
3
4
5
6
7
8
0
2
4
12
14
6
8
10
0
10
20
30 40
50 60 70 80
Time (ms)
Ω
Contact resistance (m
)
Nominal voltage multiplying factor (%)
Mechanical life test
Electrical life test
Electrical life test
10
8
10
8
10
8
Operate
Operate
Operate
Release
6
6
6
4
4
4
Release
Release
5
5
5
5
5
5
5
5
5
5
2
2
2
0
0
0
FTR-HICA012V
n=10
10 OP./Min.
FTR-HICA012V
n=10
FTR-HICA012V
n=10
10 Operations/minute
DC30V, 0 A (resistive)
500
200
500
200
100
50
20
10
5
500
1200 OP./Min.
200
100
50
20
10
5
AC250 V, 10A (Resistive)
100
50
20
10
5
Break
Make
Break
Make
5
5
Break
Make
5
5
5
5
5
5
5
5
5
5
5
10
2
2
2
10
100
200
500
1000
2000
Initial
Initial
Operation (x104)
Operation (x104)
Operation (x104)
n DIMENSIONS
l
Dimensions
l
Schematics
n
PC board mounting
hole layout
(BOTTOM VIEW)
(BOTTOM VIEW)
FTR-H1A type
28.0+0.3
12.8+0.3
1
2
3
4-ø1.3
COM
0.4
0.2
3.5
0.3
7.5
1.0
0.9
NO
5
(2.1)
(2.65)
20.0
(2.1)
3.5
20.0
FTR-H1C type
28.0+0.3
12.8+0.3
5-ø1.3
1
2
COM
NO
NC
5
4
3
(2.1)
3.5
3.5
0.4
0.2
20.0
0.2
3.5
0.9
0.3
7.5
1.0
(2.65)
3.5
(2.1)
Unit: mm
20.0
6
FTR-H1 SERIES
RoHS Compliance and Lead Free Relay Information
1. General Information
l
Relays produced after the specific date code that is indicated on each data sheet are lead-free
now. Most of our signal and power relays are lead-free. Please refer to Lead-Free Status Info.
(http://www.fujitsu.com/us/downloads/MICRO/fcai/relays/lead-free-letter.pdf)
Lead free solder paste currently used in relays is Sn-3.0Ag-0.5Cu.
All signal and most power relays also comply with RoHS. Please refer to individual data
sheets. Relays that are RoHS compliant do not contain the 5 hazardous materials that
are restricted by RoHS directive (lead, mercury, chromium IV, PBB, PBDE).
It has been verified that using lead-free relays in leaded assembly process will not cause any
problems (compatible).
l
l
l
l
l
l
“LF” is marked on each outer and inner carton. (No marking on individual relays).
To avoid leaded relays (for lead-free sample, etc.) please consult with area sales office.
We will ship leaded relays as long as the leaded relay inventory exists.
Note: Cadmium was exempted from RoHS on October 21, 2005. (Amendment to Directive 2002/95/EC)
2. Recommended Lead Free Solder Profile
l
Recommended solder paste Sn-3.0Ag-0.5Cu.
Reflow Solder condtion
Flow Solder condtion:
Pre-heating:
Soldering:
maximum 120˚C
dip within 5 sec. at
260˚C soler bath
Solder by Soldering Iron:
Soldering Iron
Temperature: maximum 360˚C
Duration:
maximum 3 sec.
We highly recommend that you confirm your actual solder conditions
3. Moisture Sensitivity
Moisture Sensitivity Level standard is not applicable to electromechanical realys.
4. Tin Whisker
l
Dipped SnAgCu solder is known as low risk tin whisker. No considerable length whisker was found by our in
house test.
7
FTR-H1 SERIES
Fujitsu Components International Headquarter Offices
Japan
Europe
Fujitsu Component Limited
Gotanda-Chuo Building
3-5, Higashigotanda 2-chome, Shinagawa-ku
Tokyo 141, Japan
Fujitsu Components Europe B.V.
Diamantlaan 25
2132 WV Hoofddorp
Netherlands
Tel: (81-3) 5449-7010
Tel: (31-23) 5560910
Fax: (81-3) 5449-2626
Fax: (31-23) 5560950
Email: promothq@ft.ed.fujitsu.com
Web: www.fcl.fujitsu.com
Email: info@fceu.fujitsu.com
Web: http://www.fujitsu.com/emea/services/components/
North and South America
Asia Pacific
Fujitsu Components America, Inc.
250 E. Caribbean Drive
Sunnyvale, CA 94089 U.S.A.
Tel: (1-408) 745-4900
Fujitsu Components Asia Ltd.
102E Pasir Panjang Road
#04-01 Citilink Warehouse Complex
Singapore 118529
Fax: (1-408) 745-4970
Tel: (65) 6375-8560
Email: marcom@fcai.fujitsu.com
Web: http://www.fujitsu.com/us/services/edevices/components/
Fax: (65) 6273-3021
Email: fcal@fcal.fujitsu.com
Web: http://www.fujitsu.com/sg/services/micro/components/
©2005 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the property off their respective
owners.
Fujitsu Components America does not warrant that the content of datasheet is error free. In a continuing effort to improve our products Fujitsu
Components America, Inc. reserves the right to change specifications/datasheets without prior notice. Rev. 11/18/2005.
ꢀ
相关型号: