MB90F347ES [FUJITSU]

16-bit Proprietary Microcontroller CMOS; 16位微控制器的专有CMOS
MB90F347ES
型号: MB90F347ES
厂家: FUJITSU    FUJITSU
描述:

16-bit Proprietary Microcontroller CMOS
16位微控制器的专有CMOS

微控制器
文件: 总85页 (文件大小:1161K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FUJITSU SEMICONDUCTOR  
DATA SHEET  
DS07-13747-1E  
16-bit Proprietary Microcontroller  
CMOS  
F2MC-16LX MB90340E Series  
MB90F342E(S), MB90F342CE(S), MB90F343E(S), MB90F343CE(S), MB90F345E(S), MB90F345CE(S),  
MB90F346E(S), MB90F346CE(S), MB90F347E(S), MB90F347CE(S), MB90F349E(S), MB90F349CE(S),  
MB90341E(S), MB90341CE(S), MB90342E(S), MB90342CE(S), MB90346E(S), MB90346CE(S), MB90347E(S),  
MB90347CE(S), MB90348E(S), MB90348CE(S), MB90349E(S), MB90349CE(S), MB90V340E-101/102  
DESCRIPTION  
The MB90340E-series with up to 2 FULL-CAN* interfaces and Flash ROM is especially designed for automotive  
and other industrial applications. Its main feature are the on-board CAN Interfaces, which conform to V2.0 Part  
A and Part B, while supporting a very flexible message buffer scheme and so offering more functions than a  
normal full CAN approach. With the new 0.35 µm CMOS technology, Fujitsu now offers on-chip Flash ROM  
program memory up to 512 Kbytes.  
The power to the MCU core (3V) is supplied by a built-in regulator circuit, giving these microcontrollers superior  
performance in terms of power consumption and tolerance to EMI.  
* : Controller Area Network (CAN) - License of Robert Bosch GmbH  
Note : F2MC is the abbreviation of FUJITSU Flexible Microcontroller.  
Be sure to refer to the “Check Sheet” for the latest cautions on development.  
“Check Sheet” is seen at the following support page  
URL : http://www.fujitsu.com/global/services/microelectronics/product/micom/support/index.html  
“Check Sheet” lists the minimal requirement items to be checked to prevent problems beforehand in system  
development.  
Copyright©2006 FUJITSU LIMITED All rights reserved  
MB90340E Series  
FEATURES  
CPU  
• Instruction system best suited to controller  
- Wide choice of data types (bit, byte, word, and long word)  
- Wide choice of addressing modes (23 types)  
- Enhanced functionality with signed multiply and divide instructions and the RETI instruction  
- Enhanced high-precision computing with 32-bit accumulator  
• Instruction system compatible with high-level language (C language) and multitask  
- Employing system stack pointer  
- Various enhanced pointer indirect instructions  
- Barrel shift instructions  
• Increased processing speed  
- 4-byte instruction queue  
Serial interface  
• UART (LIN/SCI) : up to 4 channels  
- Equipped with full-duplex double buffer  
- Clock-asynchronous or clock-synchronous serial transmission is available  
• I2C interface*1 : up to 2 channels (only for devices with a C suffix in the part number)  
- Up to 400 Kbits/s transfer rate  
Interrupt controller  
• Powerful 8-level, 34-condition interrupt feature  
• Up to 16 external interrupts are supported  
• Automatic data transfer function independent of CPU  
- Expanded intelligent I/O service function (EI2OS) : up to 16 channels  
I/O ports  
• General-purpose input/output port (CMOS output)  
- 80 ports (for devices without an S suffix in the part number - i.e. devices that support the sub clock)  
- 82 ports (for devices with an S suffix in the part number - i.e. devices that do not support the sub clock)  
8/10-bit A/D converter : 16 channels  
24 channels (only for devices with a C suffix in the part number)  
• Resolution is selectable between 8-bit and 10-bit.  
• Activation by external trigger input is allowed.  
• Conversion time : 3 µs (at 24-MHz machine clock, including sampling time)  
Program patch function  
• Detects address matches against 6 address pointers  
Timer  
• Time-base timer, watch timer, watchdog timer : 1 channel  
• 8/16-bit PPG timer : 8-bit × 16 channels, or 16-bit × 8 channels  
• 16-bit reload timer : 4 channels  
• 16-bit input/output timer  
- 16-bit free-run timer : 2 channels  
(FRT0 : ICU 0/1/2/3, OCU 0/1/2/3, FRT1 : ICU 4/5/6/7, OCU 4/5/6/7)  
- 16-bit input capture: (ICU): 8 channels  
- 16-bit output compare: (OCU): 8 channels  
2
MB90340E Series  
Full-CAN controller*2  
• Up to 2 channels  
• Compliant with Ver2.0A and Ver2.0B CAN specifications  
• 16 built-in message buffers  
• CAN wake-up function  
Low power consumption (standby) mode  
• Sleep mode (a mode that halts CPU operating clock)  
• Timebase timer mode (a mode where only the oscillation clock, sub clock, timebase timer and watch timer  
operate)  
• Watch mode (a mode that operates sub clock and clock timer only)  
• Stop mode (a mode that stops oscillation clock and sub clock)  
• CPU intermittent operation mode  
Technology  
• 0.35 µm CMOS technology  
*1 : I2C license :  
Purchase of Fujitsu I2C components conveys a license under the Philips I2C Patent Rights to use, these com-  
ponents in an I2C system provided that the system conforms to the I2C Standard Specification as defined by  
Philips.  
*2 : Controller Area Network (CAN) - License of Robert Bosch GmbH.  
3
MB90340E Series  
PRODUCT LINEUP  
MB90341E(S)*1, MB90341CE(S)*1,  
Part Number  
MB90F342E(S), MB90F342CE(S),  
MB90F343E(S)*1, MB90F343CE(S)*1, MB90342E(S)*1, MB90342CE(S)*1,  
MB90F345E(S), MB90F345CE(S),  
MB90F346E(S), MB90F346CE(S),  
MB90F347E(S), MB90F347CE(S),  
MB90F349E(S), MB90F349CE(S)  
MB90V340E-101,  
MB90V340E-102  
MB90346E(S), MB90346CE(S),  
MB90347E(S), MB90347CE(S),  
MB90348E(S)*1, MB90348CE(S)*1,  
MB90349E(S)*1, MB90349CE(S)*1  
Parameter  
Type  
CPU  
Evaluation products  
Flash memory products  
F2MC-16LX CPU  
MASK ROM products  
On-chip PLL clock multiplier (×1, ×2, ×3, ×4, ×6, 1/2 when PLL stops)  
Minimum instruction execution time : 42 ns (4 MHz osc. PLL × 6)  
System clock  
512 Kbytes :  
256 Kbytes :  
MB90F345E(S), MB90F345CE(S)  
384 Kbytes :  
MB90F343E(S), MB90F343CE(S)  
256 Kbytes :  
MB90F342E(S), MB90F342CE(S),  
MB90F349E(S), MB90F349CE(S)  
128 Kbytes :  
MB90342E(S), MB90342CE(S),  
MB90349E(S), MB90349CE(S)  
128 Kbytes :  
MB90341E(S), MB90341CE(S),  
MB90348E(S), MB90348CE(S),  
MB90347E(S), MB90347CE(S)  
64 Kbytes :  
ROM  
External  
MB90F347E(S), MB90F347CE(S)  
64 Kbytes :  
MB90346E(S), MB90346CE(S)  
MB90F346E(S), MB90F346CE(S)  
20 Kbytes :  
16 Kbytes :  
MB90F343E(S), MB90F343CE(S),  
MB90F345E(S), MB90F345CE(S)  
16 Kbytes :  
MB90F342E(S), MB90F342CE(S),  
MB90F349E(S), MB90F349CE(S)  
6 Kbytes :  
MB90341E(S), MB90341CE(S),  
MB90342E(S), MB90342CE(S),  
MB90348E(S), MB90348CE(S),  
MB90349E(S), MB90349CE(S)  
6 Kbytes :  
MB90347E(S), MB90347CE(S)  
2 Kbytes :  
MB90346E(S), MB90346CE(S)  
RAM  
30 Kbytes  
MB90F347E(S), MB90F347CE(S)  
2 Kbytes :  
MB90F346E(S), MB90F346CE(S)  
Emulator-specific  
power supply*2  
Yes  
0.35 µm CMOS with  
regulator for built-in  
power supply  
0.35 µm CMOS with built-in power supply regulator +  
Flash memory with Charge pump for programming voltage  
Technology  
3.5 V to 5.5 V : When normal operating (not using A/D converter)  
4.0 V to 5.5 V : When using the A/D converter/Flash programming  
4.5 V to 5.5 V : When using the external bus  
Operating  
voltage range  
5 V 10%  
Temperature range  
Package  
40 °C to +105 °C  
QFP-100, LQFP-100  
4 channels  
PGA-299  
5 channels  
Wide range of baud rate settings using a dedicated reload timer  
Special synchronous options for adapting to different synchronous serial protocols  
LIN functionality working either as master or slave LIN device  
UART  
Devices with a C suffix in the part number : 2channels  
2 channels  
I2C (400 kbps)  
Devices without a C suffix in the part number : ⎯  
(Continued)  
4
MB90340E Series  
MB90341E(S)*1, MB90341CE(S)*1,  
Part Number  
MB90F342E(S), MB90F342CE(S),  
MB90F343E(S)*1, MB90F343CE(S)*1, MB90342E(S)*1, MB90342CE(S)*1,  
MB90V340E-101,  
MB90V340E-102  
MB90346E(S), MB90346CE(S),  
MB90347E(S), MB90347CE(S),  
MB90348E(S)*1, MB90348CE(S)*1,  
MB90349E(S)*1, MB90349CE(S)*1  
MB90F345E(S), MB90F345CE(S),  
MB90F346E(S), MB90F346CE(S),  
MB90F347E(S), MB90F347CE(S),  
MB90F349E(S), MB90F349CE(S)  
Parameter  
Devices with a C suffix in the part number  
Devices without a C suffix in the part number : 16 channels  
: 24 channels  
24 input channels  
A/D Converter  
10-bit or 8-bit resolution  
Conversion time : Min 3 µs include sample time (per one channel)  
16-bit Reload Timer Operation clock frequency : fsys/21, fsys/23, fsys/25 (fsys = Machine clock frequency)  
(4 channels)  
Supports External Event Count function  
Generates an interrupt signal on overflow  
Supports Timer Clear when the output compare finds a match  
Operation clock freq. : fsys, fsys/21, fsys/22, fsys/23, fsys/24, fsys/25, fsys/26, fsys/27  
(fsys = Machine clock freq.)  
I/O Timer 0 (clock input FRCK0) corresponds to ICU 0/1/2/3, OCU 0/1/2/3  
I/O Timer 1 (clock input FRCK1) corresponds to ICU 4/5/6/7, OCU 4/5/6/7  
16-bit I/O Timer  
(2 channels)  
16-bit Output  
Compare  
Generates an interrupt signal when one of the 16-bit I/O timer matches the output compare  
register  
(8 channels)  
A pair of compare registers can be used to generate an output signal.  
16-bit Input Capture Rising edge, falling edge or rising & falling edge sensitive  
(8 channels)  
Signals an interrupt upon external event  
8 channels (16-bit) /16 channels (8-bit)  
Sixteen 8-bit reload counters  
Sixteen 8-bit reload registers for L pulse width  
Sixteen 8-bit reload registers for H pulse width  
8/16-bit  
Programmable  
Pulse Generator  
Supports 8-bit and 16-bit operation modes  
A pair of 8-bit reload counters can be configured as one 16-bit reload counter or as  
8-bit prescaler plus 8-bit reload counter  
Operating clock freq. : fsys, fsys/21, fsys/22, fsys/23, fsys/24 or 128 µs@fosc = 4 MHz  
(fsys = Machine clock frequency, fosc = Oscillation clock frequency)  
2 channels :  
2 channels :  
MB90F342E(S), MB90F342CE(S),  
MB90F343E(S), MB90F343CE(S),  
MB90F345E(S), MB90F345CE(S)  
1 channel :  
MB90F346E(S), MB90F346CE(S),  
MB90F347E(S), MB90F347CE(S),  
MB90F349E(S), MB90F349CE(S)  
MB90341E(S), MB90341CE(S),  
MB90342E(S), MB90342CE(S)  
1 channel :  
MB90346E(S), MB90346CE(S),  
MB90347E(S), MB90347CE(S),  
MB90348E(S), MB90348CE(S),  
MB90349E(S), MB90349CE(S)  
3 channels  
CAN Interface  
Conforms to CAN Specification Version 2.0 Part A and B  
Automatic re-transmission in case of error  
Automatic transmission in response to Remote Frames  
Prioritized 16 message buffers for data and ID’s  
Supports multiple messages  
Flexible configuration of acceptance filtering :  
Full bit compare/Full bit mask/Two partial bit masks  
Supports up to 1 Mbps  
(Continued)  
5
MB90340E Series  
(Continued)  
Part Number  
MB90F342E(S), MB90F342CE(S),  
MB90341E(S)*1, MB90341CE(S)*1,  
MB90F343E(S)*1, MB90F343CE(S)*1, MB90342E(S)*1, MB90342CE(S)*1,  
MB90V340E-101,  
MB90V340E-102  
MB90F345E(S), MB90F345CE(S),  
MB90F346E(S), MB90F346CE(S),  
MB90F347E(S), MB90F347CE(S),  
MB90F349E(S), MB90F349CE(S)  
MB90346E(S), MB90346CE(S),  
MB90347E(S), MB90347CE(S),  
MB90348E(S)*1, MB90348CE(S)*1,  
MB90349E(S)*1, MB90349CE(S)*1  
Parameter  
External Interrupt  
(16 channels)  
Can be used rising edge, falling edge, starting up by H/L level input, external interrupt,  
expanded intelligent I/O services (EI2OS) and DMA  
D/A converter  
2 channels  
Sub clock  
(maximum 100  
kHz)  
Only for  
MB90V340E-102  
Devices with sub clock : devices without an S suffix in the part number  
Devices without sub clock : devices with an S suffix in the part number  
Virtually all external pins can be used as general purpose I/O port  
All ports are push-pull outputs  
I/O Ports  
Bit-wise settable as input/output or peripheral signal  
Can be configured 8 as CMOS schmitt trigger/ automotive inputs (in blocks of 8 pins)  
TTL input level settable for external bus (32-pin only for external bus)  
Supports automatic programming, Embedded AlgorithmTM*3  
Write/Erase/Erase-Suspend/Resume commands  
A flag indicating completion of the algorithm  
Number of erase cycles : 10000 cycles  
Data retention time : 20 years  
Boot block configuration  
Flash Memory  
Erase can be performed on each block  
Block protection with external programming voltage  
Flash Security Feature for protecting the content of the Flash (except  
for MB90F346E(S) and MB90F346CE (S) )  
*1 : These devices are under development.  
*2 : It is setting of Jumper switch (TOOL VCC) when Emulator (MB2147-01) is used.  
Please refer to the Emulator hardware manual for details.  
*3 : Embedded Algorithm is a trade mark of Advanced Micro Devices Inc.  
6
MB90340E Series  
PIN ASSIGNMENTS  
• MB90V340E-101/MB90V340E-102  
(TOP VIEW)  
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51  
81  
P75/AN21/INT5  
P74/AN20/INT4  
P73/AN19/INT3  
P72/AN18/INT2  
P71/AN17/INT1  
P70/AN16/INT0  
Vss  
P04/AD04/INT12  
P05/AD05/INT13  
P06/AD06/INT14  
P07/AD07/INT15  
P10/AD08/TIN1  
P11/AD09/TOT1  
P12/AD10/SIN3/INT11R  
P13/AD11/SOT3  
P14/AD12/SCK3  
Vcc  
50  
49  
48  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
100  
P67/AN7/PPGE(F)  
P66/AN6/PPGC(D)  
P65/AN5/PPGA(B)  
P64/AN4/PPG8(9)  
P63/AN3/PPG6(7)  
P62/AN2/PPG4(5)  
P61/AN1/PPG2(3)  
P60/AN0/PPG0(1)  
AVss  
QFP - 100  
Vss  
X1  
X0  
P15/AD13/SIN4  
P16/AD14/SOT4  
P17/AD15/SCK4  
P20/A16/PPG9(8)  
P21/A17/PPGB(A)  
P22/A18/PPGD(C)  
P23/A19/PPGF(E)  
AVRL  
AVRH  
AVcc  
P57/AN15/DA01  
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30  
(FPT-100P-M06)  
* : X0A, X1A : MB90V340E-102  
P40, P41 : MB90V340E-101  
(Continued)  
7
MB90340E Series  
(Continued)  
(TOP VIEW)  
75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51  
50  
P01/AD01/INT9  
P02/AD02/INT10  
P03/AD03/INT11  
P04/AD04/INT12  
P05/AD05/INT13  
P06/AD06/INT14  
P07/AD07/INT15  
P10/AD08/TIN1  
P11/AD09/TOT1  
P12/AD10/SIN3/INT11R  
P13/AD11/SOT3  
P14/AD12/SCK3  
Vcc  
76  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
100  
MD1  
49  
48  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
MD2  
P75/AN21/INT5  
P74/AN20/INT4  
P73/AN19/INT3  
P72/AN18/INT2  
P71/AN17/INT1  
P70/AN16/INT0  
Vss  
P67/AN7/PPGE(F)  
P66/AN6/PPGC(D)  
P65/AN5/PPGA(B)  
P64/AN4/PPG8(9)  
P63/AN3/PPG6(7)  
P62/AN2/PPG4(5)  
P61/AN1/PPG2(3)  
P60/AN0/PPG0(1)  
AVss  
LQFP - 100  
Vss  
X1  
X0  
P15/AD13/SIN4  
P16/AD14/SOT4  
P17/AD15/SCK4  
P20/A16/PPG9(8)  
P21/A17/PPGB(A)  
P22/A18/PPGD(C)  
P23/A19/PPGF(E)  
P24/A20/IN0  
AVRL  
AVRH  
AVcc  
P57/AN15/DA01  
P56/AN14/DA00  
P55/AN13  
P25/A21/IN1  
P54/AN12/TOT3  
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25  
(FPT-100P-M05)  
* : X0A, X1A : MB90V340E-102  
P40, P41 : MB90V340E-101  
8
MB90340E Series  
• MB90F342E(S) / MB90F343E(S) / MB90F345E(S) / MB90F346E(S) / MB90F347E(S) / MB90F349E(S) /  
MB90341E(S) / MB90342E(S) /MB90346E(S) / MB90347E(S) / MB90348E(S) / MB90349E(S)  
(TOP VIEW)  
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51  
P75/INT5  
P74/INT4  
P73/INT3  
P72/INT2  
P71/INT1  
P70/INT0  
P04/AD04/INT12  
P05/AD05/INT13  
P06/AD06/INT14  
P07/AD07/INT15  
P10/AD08/TIN1  
P11/AD09/TOT1  
P12/AD10/SIN3/INT11R  
P13/AD11/SOT3  
P14/AD12/SCK3  
Vcc  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
100  
50  
49  
48  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
Vss  
P67/AN7/PPGE(F)  
P66/AN6/PPGC(D)  
P65/AN5/PPGA(B)  
P64/AN4/PPG8(9)  
P63/AN3/PPG6(7)  
P62/AN2/PPG4(5)  
P61/AN1/PPG2(3)  
P60/AN0/PPG0(1)  
AVss  
QFP - 100  
Vss  
X1  
X0  
P15/AD13  
P16/AD14  
P17/AD15  
P20/A16/PPG9(8)  
P21/A17/PPGB(A)  
P22/A18/PPGD(C)  
P23/A19/PPGF(E)  
AVRL  
AVRH  
AVcc  
P57/AN15  
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30  
(FPT-100P-M06)  
* : X0A, X1A : devices without an S suffix in the part number  
P40, P41 : devices with an S suffix in the part number  
(Continued)  
9
MB90340E Series  
(Continued)  
(TOP VIEW)  
75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51  
50  
76  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
100  
MD1  
P01/AD01/INT9  
P02/AD02/INT10  
P03/AD03/INT11  
P04/AD04/INT12  
P05/AD05/INT13  
P06/AD06/INT14  
P07/AD07/INT15  
P10/AD08/TIN1  
P11/AD09/TOT1  
P12/AD10/SIN3/INT11R  
P13/AD11/SOT3  
P14/AD12/SCK3  
Vcc  
49  
48  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
MD2  
P75/INT5  
P74/INT4  
P73/INT3  
P72/INT2  
P71/INT1  
P70/INT0  
Vss  
P67/AN7/PPGE(F)  
P66/AN6/PPGC(D)  
P65/AN5/PPGA(B)  
P64/AN4/PPG8(9)  
P63/AN3/PPG6(7)  
P62/AN2/PPG4(5)  
P61/AN1/PPG2(3)  
P60/AN0/PPG0(1)  
AVss  
LQFP - 100  
Vss  
X1  
X0  
P15/AD13  
P16/AD14  
P17/AD15  
AVRL  
P20/A16/PPG9(8)  
P21/A17/PPGB(A)  
P22/A18/PPGD(C)  
P23/A19/PPGF(E)  
P24/A20/IN0  
AVRH  
AVcc  
P57/AN15  
P56/AN14  
P55/AN13  
P25/A21/IN1  
P54/AN12/TOT3  
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25  
(FPT-100P-M05)  
* : X0A, X1A : devices without an S suffix in the part number  
P40, P41 : devices with an S suffix in the part number  
10  
MB90340E Series  
• MB90F342CE(S) / MB90F343CE(S) / MB90F345CE(S) / MB90F346CE(S) / MB90F347CE(S) /  
MB90F349CE(S) / MB90341CE(S) / MB90342CE(S) /MB90346CE(S) / MB90347CE(S) / MB90348CE(S) /  
MB90349CE(S)  
(TOP VIEW)  
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51  
P75/AN21/INT5  
P74/AN20/INT4  
P73/AN19/INT3  
P72/AN18/INT2  
P71/AN17/INT1  
P70/AN16/INT0  
Vss  
P04/AD04/INT12  
P05/AD05/INT13  
P06/AD06/INT14  
P07/AD07/INT15  
P10/AD08/TIN1  
P11/AD09/TOT1  
P12/AD10/SIN3/INT11R  
P13/AD11/SOT3  
P14/AD12/SCK3  
Vcc  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
100  
50  
49  
48  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
P67/AN7/PPGE(F)  
P66/AN6/PPGC(D)  
P65/AN5/PPGA(B)  
P64/AN4/PPG8(9)  
P63/AN3/PPG6(7)  
P62/AN2/PPG4(5)  
P61/AN1/PPG2(3)  
P60/AN0/PPG0(1)  
QFP - 100  
Vss  
X1  
X0  
P15/AD13  
P16/AD14  
P17/AD15  
AVss  
AVRL  
P20/A16/PPG9(8)  
P21/A17/PPGB(A)  
P22/A18/PPGD(C)  
P23/A19/PPGF(E)  
AVRH  
AVcc  
P57/AN15  
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30  
(FPT-100P-M06)  
* : X0A, X1A : devices without an S suffix in the part number  
P40, P41 : devices with an S suffix in the part number  
(Continued)  
11  
MB90340E Series  
(Continued)  
(TOP VIEW)  
75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51  
76  
P01/AD01/INT9  
P02/AD02/INT10  
P03/AD03/INT11  
P04/AD04/INT12  
P05/AD05/INT13  
P06/AD06/INT14  
P07/AD07/INT15  
P10/AD08/TIN1  
P11/AD09/TOT1  
P12/AD10/SIN3/INT11R  
P13/AD11/SOT3  
P14/AD12/SCK3  
Vcc  
50  
49  
48  
47  
46  
45  
44  
43  
42  
41  
40  
39  
38  
37  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
MD1  
77  
78  
79  
80  
81  
82  
83  
84  
85  
86  
87  
88  
89  
90  
91  
92  
93  
94  
95  
96  
97  
98  
99  
100  
1
MD2  
P75/AN21/INT5  
P74/AN20/INT4  
P73/AN19/INT3  
P72/AN18/INT2  
P71/AN17/INT1  
P70/AN16/INT0  
Vss  
P67/AN7/PPGE(F)  
P66/AN6/PPGC(D)  
P65/AN5/PPGA(B)  
P64/AN4/PPG8(9)  
P63/AN3/PPG6(7)  
P62/AN2/PPG4(5)  
P61/AN1/PPG2(3)  
P60/AN0/PPG0(1)  
AVss  
LQFP - 100  
Vss  
X1  
X0  
P15/AD13  
P16/AD14  
P17/AD15  
AVRL  
P20/A16/PPG9(8)  
P21/A17/PPGB(A)  
P22/A18/PPGD(C)  
P23/A19/PPGF(E)  
P24/A20/IN0  
AVRH  
AVcc  
P57/AN15  
P56/AN14  
P55/AN13  
P25/A21/IN1  
P54/AN12/TOT3  
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25  
(FPT-100P-M05)  
* : X0A, X1A : devices without an S suffix in the part number  
P40, P41 : devices with an S suffix in the part number  
12  
MB90340E Series  
PIN DESCRIPTION  
Pin No.  
I/O  
Pin name Circuit  
type*3  
Function  
QFP100*1 LQFP100*2  
General purpose I/O pins. The register can be set to select  
whether to use a pull-up resistor.In external bus mode, the pin is  
enabled as a general-purpose I/O port when the corresponding bit  
in the external address output control register (HACR) is 1.  
P24 to P27  
1 to 4  
99 to 2  
G
Output pins of the external address bus. When the corresponding  
bit in the external address output control register (HACR) is 0, the  
pins are enabled as high address output pins (A20 to A23).  
A20 to A23  
IN0 to IN3  
P30  
Trigger input pins for input captures.  
General purpose I/O pin.The register can be set to select whether  
to use a pull-up resistor.  
This function is enabled in single-chip mode.  
5
6
3
4
G
G
Address latch enable output pin. This function is enabled when  
the external bus is enabled.  
ALE  
IN4  
Trigger input pin for input capture.  
General purpose I/O pin.The register can be set to select whether  
to use a pull-up resistor.  
This function is enabled in single-chip mode.  
P31  
External read strobe output pin. This function is enabled when the  
external bus is enabled.  
RD  
IN5  
Trigger input pin for input capture.  
General purpose I/O pin. The register can be set to select whether  
to use a pull-up resistor. This function is enabled either in single-  
chip mode or when the WR/WRL pin output is disabled.  
P32  
Write strobe output pin for the external data bus. This function is  
enabled when both the external bus and the WR/WRL pin output  
are enabled. WRL is used to write-strobe 8 lower bits of the data  
bus in 16-bit access while WR is used to write-strobe 8 bits of the  
data bus in 8-bit access.  
7
5
G
WR / WRL  
INT10R  
P33  
External interrupt request input pin.  
General purpose I/O pin. The register can be set to select whether  
to use a pull-up resistor.This function is enabled either in single-  
chip mode or when the WRH pin output is disabled.  
8
6
G
Write strobe output pin for the upper 8 bits of the external data  
bus. This function is enabled when the external bus is enabled,  
when the external bus 16-bit mode is selected, and when the  
WRH output pin is enabled.  
WRH  
(Continued)  
13  
MB90340E Series  
Pin No.  
I/O  
Circuit  
Pin name  
Function  
QFP100*1 LQFP100*2  
type*3  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor. This function is enabled either  
in single-chip mode or when the hold function is disabled.  
P34  
9
7
8
G
G
Hold request input pin. This function is enabled when both the  
external bus and the hold function are enabled.  
HRQ  
OUT4  
Waveform output pin for output compare.  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor. This function is enabled either  
in single-chip mode or when the hold function is disabled.  
P35  
10  
Hold acknowledge output pin. This function is enabled when  
both the external bus and the hold function are enabled.  
HAK  
OUT5  
Waveform output pin for output compare.  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor. This function is enabled either  
in single-chip mode or when the external ready function is  
disabled.  
P36  
11  
9
G
G
External ready input pin. This function is enabled when both the  
external bus and the external ready function are enabled.  
RDY  
OUT6  
Waveform output pin for output compare.  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor. This function is enabled either  
in single-chip mode or when the clock output is disabled.  
P37  
12  
10  
Clock output pin. This function is enabled when both the  
external bus and clock output are enabled.  
CLK  
OUT7  
Waveform output pin for output compare OCU7  
General purpose I/O pins.  
P40, P41  
F
B
(devices with an S suffix in the part number and or  
MB90V340E-101)  
13, 14  
11, 12  
Oscillation pins for sub clock  
(devices without an S suffix in the part number and or  
MB90V340E-102)  
X0A , X1A  
15  
16  
13  
14  
VCC  
VSS  
Power (3.5 V to 5.5 V) input pin  
GND pin  
This is the power supply stabilization capacitor This pin should  
be connected to a ceramic capacitor with a capacitance greater  
than or equal to 0.1 µF.  
17  
15  
C
K
P42  
IN6  
General purpose I/O pin.  
Trigger input pin for input capture.  
18  
16  
F
RX input pin for CAN1 Interface  
(MB90F342E/F343E/F345E/341E/342E only)  
RX1  
INT9R  
External interrupt request input pin  
(Continued)  
14  
MB90340E Series  
Pin No.  
I/O  
Circuit  
Pin name  
Function  
QFP100*1 LQFP100*2  
type*3  
P43  
IN7  
General purpose I/O pin.  
Trigger input pin for input capture.  
19  
20  
21  
17  
18  
19  
F
H
H
TX Output pin for CAN1  
(MB90F342E/F343E/F345E/341E/342E only)  
TX1  
P44  
General purpose I/O pin.  
Serial data I/O pin for I2C (devices with a C suffix in the part  
number)  
SDA0  
FRCK0  
P45  
Input pin for the 16-bit I/O Timer 0  
General purpose I/O pin.  
Serial clock I/O pin for I2C (devices with a C suffix in the part  
number)  
SCL0  
FRCK1  
P46  
Input pin for the 16-bit I/O Timer  
General purpose I/O pin.  
Serial data I/O pin for I2C (devices with a C suffix in the part  
number)  
22  
23  
20  
21  
H
H
SDA1  
P47  
General purpose I/O pin.  
Serial clock I/O pin for I2C (devices with a C suffix in the part  
number)  
SCL1  
P50  
AN8  
General purpose I/O pin.  
24  
25  
26  
27  
22  
23  
24  
25  
O
I
Analog input pin for the A/D converter  
Serial data input pin for UART2  
General purpose I/O pin.  
SIN2  
P51  
AN9  
Analog input pin for the A/D converter  
Serial data output pin for UART2  
General purpose I/O pin.  
SOT2  
P52  
AN10  
SCK2  
P53  
I
Analog input pin for the A/D converter  
Clock I/O pin for UART2  
General purpose I/O pin.  
AN11  
TIN3  
I
Analog input pin for the A/D converter  
Event input pin for the reload timer  
General purpose I/O pin.  
P54  
28  
29  
26  
27  
AN12  
TOT3  
P55  
I
I
Analog input pin for the A/D converter  
Output pin for the reload timer  
General purpose I/O pin.  
AN13  
P56, P57  
AN14, AN15  
AVCC  
Analog input pin for the A/D converter  
General purpose I/O pins.  
30, 31  
32  
28, 29  
30  
J
Analog input pins for the A/D converter  
Analog power input pin for the A/D Converter  
(Continued)  
K
15  
MB90340E Series  
Pin No.  
I/O  
Pin name  
Circuit  
Function  
QFP100*1 LQFP100*2  
type*3  
Reference voltage input pin for the A/D Converter. This power  
supply must be turned on or off while a voltage higher than or  
equal to AVRH is applied to AVCC.  
33  
31  
AVRH  
L
34  
35  
32  
33  
AVRL  
AVSS  
K
K
Lower reference voltage input pin for the A/D Converter  
Analog GND pin for the A/D Converter  
General purpose I/O pins.  
P60 to P67  
AN0 to AN7  
Analog input pins for the A/D converter  
36 to 43  
44  
34 to 41  
42  
I
I
PPG0, 2, 4, 6,  
8, A, C, E  
Output pins for PPGs  
VSS  
GND pin  
P70 to P75  
General purpose I/O pins.  
Analog input pins for the A/D converter (devices with a C suffix  
in the part number)  
45 to 50  
43 to 48 AN16 to AN21  
INT0 to INT5  
External interrupt request input pins  
Input pin for specifying the operating mode.  
Input pins for specifying the operating mode.  
Reset input  
51  
52, 53  
54  
49  
50, 51  
52  
MD2  
MD1, MD0  
RST  
D
C
E
P76, P77  
General purpose I/O pins.  
Analog input pins for the A/D converter (devices with a C suffix  
in the part number)  
55, 56  
57  
53, 54  
55  
AN22, AN23  
I
INT6, INT7  
P80  
External interrupt request input pins  
General purpose I/O pin.  
TIN0  
Event input pin for the reload timer  
Trigger input pin for the A/D converter  
External interrupt request input pin  
General purpose I/O pin.  
F
ADTG  
INT12R  
P81  
TOT0  
CKOT  
INT13R  
P82  
Output pin for the reload timer  
Output pin for the clock monitor  
External interrupt request input pin  
General purpose I/O pin.  
58  
56  
F
SIN0  
Serial data input pin for UART0  
Event input pin for the reload timer  
External interrupt request input pin  
General purpose I/O pin.  
59  
60  
57  
58  
M
F
TIN2  
INT14R  
P83  
SOT0  
TOT2  
Serial data output pin for UART0  
Output pin for the reload timer  
(Continued)  
16  
MB90340E Series  
Pin No.  
I/O  
Pin name  
Circuit  
Function  
QFP100*1 LQFP100*2  
type*3  
P84  
SCK0  
General purpose I/O pin.  
61  
59  
F
Clock I/O pin for UART0  
External interrupt request input pin  
General purpose I/O pin.  
Serial data input pin for UART1  
General purpose I/O pin.  
Serial data output pin for UART1  
General purpose I/O pin.  
Clock I/O pin for UART1  
Power (3.5 V to 5.5 V) input pin  
GND pin  
INT15R  
P85  
62  
63  
64  
60  
61  
62  
M
F
SIN1  
P86  
SOT1  
P87  
F
SCK1  
65  
66  
63  
64  
VCC  
VSS  
P90 to P93  
PPG1, 3, 5, 7  
P94 to P97  
General purpose I/O pin  
Output pins for PPGs  
67 to 70  
65 to 68  
F
General purpose I/O pin  
71 to 74  
69 to 72  
F
OUT0 to  
OUT3  
Waveform output pins for output compares. This function is  
enabled when the OCU enables waveform output.  
PA0  
RX0  
General purpose I/O pin.  
75  
76  
73  
74  
F
F
RX input pin for CAN0 Interface  
External interrupt request input pin  
General purpose I/O pin.  
INT8R  
PA1  
TX0  
TX Output pin for CAN0  
General purpose I/O pins. The register can be set to select  
whether to use a pull-up resistor. This function is enabled in  
single-chip mode.  
P00 to P07  
77 to 84  
75 to 82  
G
G
I/O pins for 8 lower bits of the external address/data bus.  
This function is enabled when the external bus is enabled.  
AD00 to AD07  
INT8 to INT15  
External interrupt request input pins.  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor.  
This function is enabled in single-chip mode.  
P10  
85  
83  
I/O pin for the external address/data bus.  
This function is enabled when the external bus is enabled.  
AD08  
TIN1  
Event input pin for the reload timer  
(Continued)  
17  
MB90340E Series  
Pin No.  
I/O  
Circuit  
Pin name  
Function  
QFP100*1 LQFP100*2  
type*3  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor. This function is enabled in  
single-chip mode.  
P11  
86  
87  
84  
85  
G
N
I/O pin for the external address/data bus. This function is  
enabled when the external bus is enabled.  
AD09  
TOT1  
Output pin for the reload timer  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor.  
This function is enabled in single-chip mode.  
P12  
I/O pin for the external address/data bus. This function is  
enabled when the external bus is enabled.  
AD10  
SIN3  
Serial data input pin for UART3  
INT11R  
External interrupt request input pin  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor.  
P13  
This function is enabled in single-chip mode.  
88  
89  
86  
87  
G
G
I/O pin for the external address/data bus. This function is  
enabled when the external bus is enabled.  
AD11  
SOT3  
Serial data output pin for UART3  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor.  
This function is enabled in single-chip mode.  
P14  
I/O pin for the external address/data bus. This function is  
enabled when the external bus is enabled.  
AD12  
SCK3  
VCC  
VSS  
X1  
Clock I/O pin for UART3  
Power (3.5 V to 5.5 V) input pin  
GND pin  
90  
91  
92  
93  
88  
89  
90  
91  
Main clock output pin  
Main clock input pin  
A
X0  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor.  
This function is enabled in single-chip mode.  
P15  
AD13  
P16  
94  
95  
92  
93  
G
I/O pin for the external address/data bus. This function is  
enabled when the external bus is enabled.  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor.  
This function is enabled in single-chip mode.  
G
I/O pin for the external address/data bus. This function is  
enabled when the external bus is enabled.  
AD14  
(Continued)  
18  
MB90340E Series  
(Continued)  
Pin No.  
QFP100*1 LQFP100*2  
Circuit  
type*3  
Pin name  
Function  
General purpose I/O pin. The register can be set to select  
whether to use a pull-up resistor.  
P17  
This function is enabled in single-chip mode.  
96  
94  
G
I/O pin for the external address/data bus. This function is  
enabled when the external bus is enabled.  
AD15  
General purpose I/O pins. The register can be set to select  
whether to use a pull-up resistor.In external bus mode, the pin  
is enabled as a general-purpose I/O port when the  
corresponding bit in the external address output control  
register (HACR) is 1.  
P20 to P23  
97 to 100  
95 to 98  
G
Output pins of the external address bus. When the  
corresponding bit in the external address output control  
register (HACR) is 0, the pins are enabled as high address  
output pins (A16 to A19).  
A16 to A19  
PPG9,PPGB,  
PPGD,PPGF  
Output pins for PPGs  
*1 : FPT-100P-M06  
*2 : FPT-100P-M05  
*3 : For I/O circuit type, refer to “I/O CIRCUIT TYPE”.  
19  
MB90340E Series  
I/O CIRCUIT TYPE  
Type  
Circuit  
Remarks  
Oscillation circuit  
• High-speed oscillation feedback  
resistor = approx. 1 MΩ  
X1  
X0  
Xout  
A
Standby control signal  
Oscillation circuit  
X1A  
X0A  
• Low-speed oscillation feedback  
resistor = approx. 10 MΩ  
Xout  
B
C
Standby control signal  
MASK ROM and evaluation products:  
• CMOS hysteresis input pin  
Flash memory products:  
R
R
CMOS hysteresis  
inputs  
• CMOS input pin  
MASK ROM and evaluation products:  
• CMOS hysteresis input pin  
• Pull-down resistor value: approx. 50 kΩ  
Flash memory products:  
CMOS hysteresis  
inputs  
D
• CMOS input pin  
• No pull-down  
Pull-down  
Resistor  
CMOS hysteresis input pin  
• Pull-up resistor value: approx. 50 kΩ  
Pull-up  
E
Resistor  
R
CMOS hysteresis  
inputs  
(Continued)  
20  
MB90340E Series  
Type  
Circuit  
Remarks  
• CMOS level output  
(IOL = 4 mA, IOH = −4 mA)  
P-ch  
N-ch  
Pout  
Nout  
• CMOS hysteresis input (with function to  
disconnect input during standby)  
• Automotive input (with function to  
disconnect input during standby)  
R
F
CMOS hysteresis  
input  
Automotive input  
Standby control for  
input shutdown  
• CMOS level output  
Pull-up control  
(IOL = 4 mA, IOH = −4 mA)  
• CMOS hysteresis input (with function to  
disconnect input during standby)  
• Automotive input (with function to  
disconnect input during standby)  
• TTL input (with function to disconnect  
input during standby)  
P-ch  
P-ch  
Pout  
Nout  
N-ch  
R
G
• Programmable pull-up resistor: 50 kΩ  
approx.  
CMOS hysteresis  
input  
Automotive input  
TTL input  
Standby control for  
input shutdown  
• CMOS level output  
(IOL = 3 mA, IOH = −3 mA)  
P-ch  
Pout  
• CMOS hysteresis input (with function to  
disconnect input during standby)  
• Automotive input (with function to  
disconnect input during standby)  
N-ch  
Nout  
H
R
CMOS hysteresis  
input  
Automotive input  
Standby control for  
input shutdown  
(Continued)  
21  
MB90340E Series  
Type  
Circuit  
Remarks  
• CMOS level output  
(IOL = 4 mA, IOH = −4 mA)  
P-ch  
N-ch  
Pout  
Nout  
• CMOS hysteresis input (with function to  
disconnect input during standby)  
• Automotive input (with function to  
disconnect input during standby)  
• A/D converter analog input  
R
I
CMOS hysteresis  
input  
Automotive input  
Standby control for  
input shutdown  
Analog input  
• CMOS level output  
(IOL = 4 mA, IOH = −4 mA)  
• D/A analog output  
P-ch  
N-ch  
Pout  
• CMOS hysteresis input (with function to  
disconnect input during standby)  
• Automotive input (with function to  
disconnect input during standby)  
• A/D converter analog input  
Nout  
R
CMOS hysteresis  
input  
J
Automotive input  
Standby control for  
input shutdown  
Analog input  
Analog output  
• Power supply input protection circuit  
P-ch  
N-ch  
K
• A/D converter reference voltage power  
supply input pin, with the protection  
circuit  
• Flash memory devices do not have a  
protection  
ANE  
AVR  
P-ch  
N-ch  
L
ANE  
circuit against VCC for pin AVRH  
(Continued)  
22  
MB90340E Series  
(Continued)  
Type  
Circuit  
Remarks  
• CMOS level output  
(IOL = 4 mA, IOH = −4 mA)  
• CMOS input (with function to disconnect  
input during standby)  
• Automotive input (with function to  
disconnect input during standby)  
P-ch  
N-ch  
Pout  
Nout  
M
R
CMOS input  
Automotive input  
Standby control for  
input shutdown  
• CMOS level output  
(IOL = 4 mA, IOH = −4 mA)  
• CMOS input (with function to disconnect  
input during standby)  
Pull-up control  
Pout  
P-ch  
P-ch  
• Automotive input (with function to  
disconnect input during standby)  
• TTL input (with function to disconnect  
input during standby)  
Programmable pull-up resistor: 50 kΩ  
approx  
N-ch  
Nout  
R
N
CMOS input  
Automotive input  
TTL input  
Standby control for  
input shutdown  
• CMOS level output  
(IOL = 4 mA, IOH = −4 mA)  
• CMOS input (with function to disconnect  
input during standby)  
• Automotive input (with function to  
disconnect input during standby)  
• A/D converter analog input  
P-ch  
N-ch  
Pout  
Nout  
R
O
CMOS input  
Automotive input  
Standby control for  
input shutdown  
Analog input  
23  
MB90340E Series  
HANDLING DEVICES  
1. Preventing latch-up  
CMOS IC chips may suffer latch-up under the following conditions:  
• A voltage higher than VCC or lower than VSS is applied to an input or output pin.  
• A voltage higher than the rated voltage is applied between VCC and VSS pins.  
• The AVCC power supply is applied before the VCC voltage.  
Latch-up may increase the power supply current drastically, causing thermal damage to the device.  
For the same reason, also be careful not to let the analog power-supply voltage (AVCC, AVRH) exceed the digital  
power-supply voltage.  
2. Handling unused pins  
Leaving unused input pins open may result in misbehavior or latch-up and possible permanent damage to the  
device. Therefore they must be pulled up or pulled down through resistors. In this case those resistors should  
be more than 2 k.  
Unused bidirectional pins should be set to the output state and can be left open, or the input state with the above  
described connection.  
3. Power supply pins (VCC/VSS)  
• If there are multiple VCC and VSS pins, that are designed to be set to the same potential are connected the  
inside of the device to prevent malfunctions such as latch-up.  
To reduce unnecessary radiation, prevent malfunctioning of the strobe signal due to the rise of ground level,  
and observe the standard for total output current, be sure to connect the VCC and VSS pins to the power supply  
and ground externally. Connect VCC and VSS pins to the device from the current supply source at a low imped-  
ance.  
• As a measure against power supply noise, connect a capacitor of about 0.1 µF as a bypass capacitor between  
VCC and VSS pins in the vicinity of VCC and VSS pins of the device  
Vcc  
Vss  
Vcc  
Vss  
Vss  
Vcc  
MB90340E  
Series  
Vcc  
Vss  
Vcc  
Vss  
4. Mode Pins (MD0 to MD2)  
Connect the mode pins directly to VCC or VSS pins. To prevent the device unintentionally entering test mode due  
to noise, lay out the printed circuit board so as to minimize the distance from the mode pins to VCC or VSS pins  
and to provide a low-impedance connection.  
24  
MB90340E Series  
5. Sequence for Turning On the Power Supply to the A/D Converter and Analog Inputs  
Make sure to turn on the A/D converter power supply (AVCC, AVRH, AVRL) and analog inputs (AN0 to AN23)  
after turning-on the digital power supply (VCC).  
Turn-off the digital power after turning off the A/D converter supply and analog inputs. In this case, make sure  
that the voltage does not exceed AVRH or AVCC (turning on/off the analog and digital power supplies simulta-  
neously is acceptable).  
6. Connection of Unused A/D Converter Pins when the A/D Converter is Used  
Connect unused pins of A/D converter to AVCC = VCC, AVSS = AVRH = AVRL = VSS.  
7. Crystal Oscillator Circuit  
The X0, X1 pins and X0A, X1A pins may be possible causes of abnormal operation. Make sure to provide bypass  
capacitors via the shortest distance from X0, X1 pins and X0A, X1A pins, crystal oscillator (or ceramic oscillator)  
and ground lines, and make sure, to the utmost effort, that the oscillation circuit lines do not cross the lines of  
other circuits. It is highly recommended to provide a printed circuit board art work surrounding X0, X1 pins and  
X0A, X1A pins with a ground area for stabilizing the operation.  
For each of the mass-production products, request an oscillator evaluation from the manufacturer of the oscillator  
you are using.  
8. Pull-up/down resistors  
The MB90340E Series does not support internal pull-up/down resistors (except for the pull-up resistors built into  
ports 0 to 3). Use external components where needed.  
9. Using external clock  
To use an external clock, drive the X0 pin and leave the X1 pin open.  
MB90340E Series  
X0  
Open  
X1  
10. Precautions when not using a sub clock signal  
If you do not connect pins X0A and X1A to an oscillator, use pull-down handling on the X0A pin, and leave the  
X1A pin open.  
11. Notes on operation in PLL clock mode  
If PLL clock mode is selected, the microcontroller attempt to be working with the self-oscillating circuit even when  
there is no external oscillator or the external clock input is stopped. Performance of this operation, however,  
cannot be guaranteed.  
12. Notes on Power-On  
To prevent the internal regulator circuit from malfunctioning, set the voltage rise time during power-on to 50 µs  
or more (0.2 V to 2.7 V)  
13. Stabilization of power supply voltage  
A sudden change in the supply voltage may cause the device to malfunction even within the specified VCC supply  
voltage operating range. Therefore, the VCC supply voltage should be stabilized.  
Stabilize the power supply voltage as follows as a standard level of stabilization.  
25  
MB90340E Series  
• VCC ripple variations (peak-to-peak value) at commercial frequencies (50 Hz/60 Hz) fall below 10% of the  
standard VCC supply voltage  
• The coefficient of fluctuation does not exceed 0.1 V/ms at instantaneous power switching.  
14. Initialization  
Inthedevice, thereareinternalregisterswhichareinitializedonlybyapower-onreset. Toinitializetheseregisters,  
turn on the power again.  
15. Port 0 to Port 3 Output During Power-on (External-bus Mode)  
As shown below, when the power is turned on in External-Bus mode, there is a possibility that output signal of  
Port 0 to Port 3 might be unstable irrespective of the reset input.  
1/2VCC  
VCC  
Port0 to Port3  
Port0 to Port3 outputs  
might be unstable  
Port0 to Port3 outputs = Hi-Z  
16. Notes on Using the CAN Function  
To use the CAN function, please set the DIRECT bit of the CAN Direct Mode Register (CDMR) to 1.  
If the DIRECT bit is set to ’0’ (initial value), wait states will be performed when accessing CAN registers.  
Note : Please refer to the Hardware Manual of the MB90340E series for detail of CAN Direct Mode Register.  
17. Flash Security Function (except for MB90F346E)  
A security bit is located in the area of the flash memory.  
If protection code 01H is written in the security bit, the flash memory is in the protected state by security.  
Therefore please do not write 01H in this address if you do not use the security function.  
Refer to following table for the address of the security bit.  
Flash memory size  
Address of the security bit  
MB90F347E  
Embedded 1 Mbit Flash Memory  
FE0001H  
MB90F342E  
MB90F349E  
Embedded 2 Mbits Flash Memory  
FC0001H  
MB90F343E  
MB90F345E  
Embedded 3 Mbits Flash Memory  
Embedded 4 Mbits Flash Memory  
F90001H  
F80001H  
26  
MB90340E Series  
BLOCK DIAGRAMS  
MB90V340E-101/102  
X0,X1  
X0A,X1A*  
RST  
Clock  
16LX  
CPU  
Controller  
FRCK0  
IO Timer 0  
RAM  
30 Kbytes  
Input  
Capture  
IN7 to IN0  
8 channels  
Output  
Compare  
8 channels  
OUT7 to OUT0  
FRCK1  
Prescaler  
5 channels  
IO Timer 1  
SOT4 to SOT0  
SCK4 to SCK0  
SIN4 to SIN0  
CAN  
Controller  
3 channels  
UART  
5 channels  
RX2 to RX0  
TX2 to TX0  
16-bit Reload  
Timer  
4 channels  
AVCC  
TIN3 to TIN0  
AVSS  
TOT3 to TOT0  
8/10-bit  
A/D converter  
24 channels  
AN23 to AN0  
AVRH  
AVRL  
ADTG  
AD15 to AD00  
A23 to A16  
ALE  
RD  
10-bit  
D/A converter  
2 channels  
External  
Bus  
Interface  
WR/WRL  
WRH  
DA01, DA00  
HRQ  
HAK  
8/16-bit  
PPG  
16 channels  
PPGF to PPG0  
RDY  
CLK  
I2C  
Interface  
2 channels  
SDA1, SDA0  
SCL1, SCL0  
INT15 to INT8  
(INT15R to INT8R)  
External  
Interrupt  
16 channels  
INT7 to INT0  
DMAC  
Clock  
CKOT  
Monitor  
* : Only for MB90V340E-102  
27  
MB90340E Series  
MB90F342E(S), MB90F342CE(S), MB90F343E(S), MB90F343CE(S), MB90F345E(S), MB90F345CE(S), , MB90F346E(S),  
MB90F346CE(S), MB90F347E(S), MB90F347CE(S), MB90F349E(S), MB90F349CE(S), MB90341E(S), MB90341CE(S),  
MB90342E(S), MB90342CE(S), MB90346E(S), MB90346CE(S), MB90347E(S), MB90347CE(S), MB90348E(S),  
MB90348CE(S), MB90349E(S), MB90349CE(S)  
X0,X1  
X0A,X1A*1  
Clock  
16LX  
CPU  
Controller  
RST  
RAM  
2 K/6 K/16 K/  
20 Kbytes  
FRCK0  
IO Timer 0  
Input  
Capture  
IN7 to IN0  
8 channels  
ROM/Flash  
64 K/128 K  
256 K/384 K/  
512 Kbytes  
Output  
Compare  
8 channels  
OUT7 to OUT0  
FRCK1  
Prescaler  
4 channels  
IO Timer 1  
SOT3 to SOT0  
SCK3 to SCK0  
SIN3 to SIN0  
CAN  
Controller  
1/2 channels*3  
RX0, RX1*3  
TX0, TX1*3  
UART  
4 channels  
16-bit Reload  
Timer  
4 channels  
AVCC  
TIN3 to TIN0  
AVSS  
TOT3 to TOT0  
8/10-bit  
AN15 to AN0  
AN23 to AN16*2  
AVRH  
A/D converter  
16/24  
AD15 to AD00  
A23 to A16  
ALE  
channels  
AVRL  
ADTG  
RD  
External  
Bus  
Interface  
WR/WRL  
WRH  
8/16-bit  
PPG  
16 channels  
HRQ  
PPGF to PPG0  
HAK  
RDY  
CLK  
I2C  
Interface  
2 channels  
SDA1, SDA0*2  
SCL1, SCL0*2  
INT15 to INT8  
(INT15R to INT8R)  
External  
Interrupt  
INT7 to INT0  
16 channels  
DMAC  
Clock  
Monitor  
CKOT  
*1 : Only for devices with an S suffix in the part number  
*2 : Only for devices with a C suffix in the part number  
*3 : Only the MB90341E(S)/ 341CE(S)/ 342E(S)/ 342CE(S)/ F342E(S)/F342CE(S)/F343E(S)/F343CE(S)/  
F345E(S)/F345CE(S) are equipped with 2 CAN channels  
28  
MB90340E Series  
MEMORY MAP  
MB90V340E-101/102  
MB90F345E(S)/F345CE(S)  
MB90F343E(S)/F343CE(S)  
000000H  
0000EFH  
000000H  
0000EFH  
000000H  
Peripheral  
0000EFH  
Peripheral  
Peripheral  
External access area  
External access area  
External access area  
000100H  
000100H  
000100H  
RAM 20 Kbytes  
RAM 20 Kbytes  
RAM 30 Kbytes  
0050FFH  
007900H  
0050FFH  
0078FFH  
007900H  
007900H  
Peripheral  
007FFFH  
Peripheral  
Peripheral  
007FFFH  
008000H  
007FFFH  
008000H  
008000H  
ROM  
ROM  
ROM  
(image of FF bank)  
(image of FF bank)  
(image of FF bank)  
00FFFFH  
00FFFFH  
00FFFFH  
F80000H  
External access area  
External access area  
ROM (F8 bank)  
External access area  
F80000H  
F80000H  
ROM (F8 bank)  
F8FFFFH  
F8FFFFH  
F8FFFFH  
F90000H  
F90000H  
F90000H  
ROM (F9 bank)  
ROM (FA bank)  
ROM (FB bank)  
ROM (FC bank)  
ROM (FD bank)  
ROM (FE bank)  
ROM (FF bank)  
ROM (F9 bank)  
ROM (FA bank)  
ROM (FB bank)  
ROM (FC bank)  
ROM (FD bank)  
ROM (FE bank)  
ROM (FF bank)  
ROM (F9 bank)  
F9FFFFH  
F9FFFFH  
FA0000H  
F9FFFFH  
FA0000H  
FA0000H  
ROM (FA bank)  
FAFFFFH  
FB0000H  
FAFFFFH  
FB0000H  
FAFFFFH  
FB0000H  
ROM (FB bank)  
FBFFFFH  
FC0000H  
FBFFFFH  
FC0000H  
FBFFFFH  
FC0000H  
FCFFFFH  
FD0000H  
FCFFFFH  
FD0000H  
FCFFFFH  
FD0000H  
ROM (FD bank)  
FDFFFFH  
FE0000H  
FDFFFFH  
FE0000H  
FDFFFFH  
FE0000H  
ROM (FE bank)  
FEFFFFH  
FF0000H  
FEFFFFH  
FF0000H  
FEFFFFH  
FF0000H  
ROM (FF bank)  
FFFFFFH  
FFFFFFH  
FFFFFFH  
: Not accessible  
29  
MB90340E Series  
MB90349E(S)/349CE(S)  
MB90342E(S)/342CE(S)  
MB90F349E(S)/F349CE(S)  
MB90F342E(S)/F342CE(S)  
MB90348E(S)/348CE(S)  
MB90341E(S)/341CE(S) MB90F347E(S)/F347CE(S)  
MB90347E(S)/347CE(S)  
MB90346E(S)/346CE(S)  
MB90F346E(S)/F346CE(S)  
000000H  
0000EFH  
000000H  
0000EFH  
000000H  
0000EFH  
000000H  
0000EFH  
Peripheral  
Peripheral  
Peripheral  
Peripheral  
External access area  
RAM 2 Kbytes  
External access area  
External access area  
External access area  
000100H  
000100H  
000100H  
0008FFH  
000100H  
RAM 6 Kbytes  
0018FFH  
RAM 16 Kbytes  
RAM 16 Kbytes  
003FFFH  
003FFFH  
007900H  
007900H  
007900H  
007900H  
Peripheral  
Peripheral  
Peripheral  
Peripheral  
007FFFH  
007FFFH  
007FFFH  
007FFFH  
008000H  
008000H  
008000H  
008000H  
ROM (image  
of FF bank)  
ROM (image  
of FF bank)  
ROM (image  
of FF bank)  
ROM (image  
of FF bank)  
00FFFFH  
00FFFFH  
00FFFFH  
00FFFFH  
External  
External  
External  
External  
access area  
access area  
access area  
access area  
FC0000H  
ROM (FC bank)  
FCFFFFH  
FD0000H  
ROM (FD bank)  
FDFFFFH  
FE0000H  
FE0000H  
FE0000H  
FE0000H  
ROM (FE bank)  
ROM (FE bank)  
ROM (FF bank)  
ROM (FE bank)  
ROM (FF bank)  
FEFFFFH  
FEFFFFH  
FF0000H  
FEFFFFH  
FF0000H  
FEFFFFH  
FF0000H  
FF0000H  
ROM (FF bank)  
FFFFFFH  
ROM (FF bank)  
FFFFFFH  
FFFFFFH  
FFFFFFH  
: Not accessible  
Note: An image of the data in the FF bank of ROM is visible in the upper part of bank 00, which makes it possible  
for the C compiler to use the small memory model. The lower 16 bits of addresses in the FF bank are the  
same as the lower 16 bits of addresses in the 00 bank so that tables stored in the ROM can be accessed  
without using the far specifier in the pointer declaration.  
For example, when the address 00C000H is accessed, the data at FFC000H in ROM is actually accessed.  
The ROM area in bank FF exceeds 32 Kbytes, and its entire image cannot be shown in bank 00.  
Asaresult, theimagebetweenFF8000H andFFFFFFH isvisibleinbank00, whiletheimagebetweenFF0000H  
and FF7FFFH is visible only in bank FF.  
30  
MB90340E Series  
I/O MAP  
Address  
Register  
Abbreviation Access  
Resource name  
Port 0  
Initial value  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
11111111B  
11111111B  
11111111B  
XXXXXXXXB  
XXXX0XXXB  
00000000B  
00000000B  
00000000B  
00000000B  
00000000B  
00000000B  
00000000B  
00000000B  
00000000B  
00000000B  
00000100B  
000000H Port 0 Data Register  
PDR0  
PDR1  
PDR2  
PDR3  
PDR4  
PDR5  
PDR6  
PDR7  
PDR8  
PDR9  
PDRA  
ADER5  
ADER6  
ADER7  
ILSR0  
ILSR1  
DDR0  
DDR1  
DDR2  
DDR3  
DDR4  
DDR5  
DDR6  
DDR7  
DDR8  
DDR9  
DDRA  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
000001H Port 1 Data Register  
Port 1  
000002H Port 2 Data Register  
Port 2  
000003H Port 3 Data Register  
Port 3  
000004H Port 4 Data Register  
Port 4  
000005H Port 5 Data Register  
Port 5  
000006H Port 6 Data Register  
Port 6  
000007H Port 7 Data Register  
Port 7  
000008H Port 8 Data Register  
Port 8  
000009H Port 9 Data Register  
Port 9  
00000AH Port A Data Register  
Port A  
00000BH Port 5 Analog Input Enable Register  
00000CH Port 6 Analog Input Enable Register  
00000DH Port 7 Analog Input Enable Register  
00000EH Input Level Select Register 0  
00000FH Input Level Select Register 1  
000010H Port 0 Direction Register  
000011H Port 1 Direction Register  
000012H Port 2 Direction Register  
000013H Port 3 Direction Register  
000014H Port 4 Direction Register  
000015H Port 5 Direction Register  
000016H Port 6 Direction Register  
000017H Port 7 Direction Register  
000018H Port 8 Direction Register  
000019H Port 9 Direction Register  
00001AH Port A Direction Register  
00001BH  
Port 5, A/D  
Port 6, A/D  
Port 7, A/D  
Ports  
Ports  
Port 0  
Port 1  
Port 2  
Port 3  
Port 4  
Port 5  
Port 6  
Port 7  
Port 8  
Port 9  
Port A  
Reserved  
00001CH Port 0 Pull-up Control Register  
00001DH Port 1 Pull-up Control Register  
00001EH Port 2 Pull-up Control Register  
00001FH Port 3 Pull-up Control Register  
PUCR0  
PUCR1  
PUCR2  
PUCR3  
R/W  
R/W  
Port 0  
Port 1  
Port 2  
Port 3  
00000000B  
00000000B  
00000000B  
00000000B  
R/W  
W, R/W  
(Continued)  
31  
MB90340E Series  
Address  
Register  
Abbreviation Access Resource name Initial value  
000020H Serial Mode Register 0  
SMR0  
SCR0  
W,R/W  
W,R/W  
R/W  
00000000B  
00000000B  
00000000B  
00001000B  
000021H Serial Control Register 0  
000022H Reception/Transmission Data Register 0  
000023H Serial Status Register 0  
RDR0/TDR0  
SSR0  
R,R/W  
UART0  
Extended Communication Control  
Register 0  
R,W,  
R/W  
000024H  
ECCR0  
000000XXB  
000025H Extended Status/Control Register 0  
000026H Baud Rate Generator Register 00  
000027H Baud Rate Generator Register 01  
000028H Serial Mode Register 1  
ESCR0  
BGR00  
BGR01  
SMR1  
R/W  
R/W  
00000100B  
00000000B  
00000000B  
00000000B  
00000000B  
00000000B  
00001000B  
R/W  
W,R/W  
W,R/W  
R/W  
000029H Serial Control Register 1  
SCR1  
00002AH Reception/Transmission Data Register 1  
00002BH Serial Status Register 1  
RDR1/TDR1  
SSR1  
R,R/W  
UART1  
Extended Communication Control  
Register 1  
R,W,  
R/W  
00002CH  
ECCR1  
000000XXB  
00002DH Extended Status/Control Register 1  
00002EH Baud Rate Generator Register 10  
00002FH Baud Rate Generator Register 11  
000030H PPG 0 Operation Mode Control Register  
000031H PPG 1 Operation Mode Control Register  
000032H PPG 0/PPG 1 Count Clock Select Register  
000033H  
ESCR1  
BGR10  
BGR11  
PPGC0  
PPGC1  
PPG01  
Reserved  
PPGC2  
PPGC3  
PPG23  
Reserved  
PPGC4  
PPGC5  
PPG45  
R/W  
R/W  
00000100B  
00000000B  
00000000B  
0X000XX1B  
R/W  
W,R/W  
W,R/W 16-bit PPG 0/1 0X000001B  
R/W  
000000X0B  
000034H PPG 2 Operation Mode Control Register  
000035H PPG 3 Operation Mode Control Register  
000036H PPG 2/PPG 3 Count Clock Select Register  
000037H  
W,R/W  
0X000XX1B  
W,R/W 16-bit PPG 2/3 0X000001B  
R/W  
000000X0B  
000038H PPG 4 Operation Mode Control Register  
000039H PPG 5 Operation Mode Control Register  
00003AH PPG 4/PPG 5 Clock Select Register  
W,R/W  
0X000XX1B  
W,R/W 16-bit PPG 4/5 0X000001B  
R/W  
000000X0B  
00000000B  
0X000XX1B  
Address Match  
Detection 1  
00003BH Address Detect Control Register 1  
PACSR1  
R/W  
00003CH PPG 6 Operation Mode Control Register  
00003DH PPG 7 Operation Mode Control Register  
00003EH PPG 6/PPG 7 Count Clock Control Register  
00003FH  
PPGC6  
PPGC7  
W,R/W  
W,R/W 16-bit PPG 6/7 0X000001B  
PPG67  
R/W  
000000X0B  
Reserved  
(Continued)  
32  
MB90340E Series  
Address  
Register  
Abbreviation Access Resource name  
Initial value  
0X000XX1B  
0X000001B  
000040H PPG 8 Operation Mode Control Register  
000041H PPG 9 Operation Mode Control Register  
PPGC8  
PPGC9  
W,R/W  
W,R/W  
16-bit PPG 8/9  
16-bit PPG A/B  
16-bit PPG C/D  
16-bit PPG E/F  
PPG 8/PPG 9 Count Clock Control  
000042H  
Register  
PPG89  
R/W  
000000X0B  
000043H  
Reserved  
PPGCA  
000044H PPG A Operation Mode Control Register  
000045H PPG B Operation Mode Control Register  
W,R/W  
W,R/W  
0X000XX1B  
0X000001B  
PPGCB  
PPG A/PPG B Count Clock Select  
000046H  
Register  
PPGAB  
R/W  
000000X0B  
000047H  
Reserved  
PPGCC  
000048H PPG C Operation Mode Control Register  
000049H PPG D Operation Mode Control Register  
W,R/W  
W,R/W  
0X000XX1B  
0X000001B  
PPGCD  
PPG C/PPG D Count Clock Select  
00004AH  
Register  
PPGCD  
R/W  
000000X0B  
00004BH  
Reserved  
PPGCE  
00004CH PPG E Operation Mode Control Register  
00004DH PPG F Operation Mode Control Register  
W,R/W  
W,R/W  
0X000XX1B  
0X000001B  
PPGCF  
PPG E/PPG F Count Clock Select  
00004EH  
Register  
PPGEF  
R/W  
000000X0B  
00004FH  
Reserved  
ICS01  
ICE01  
ICS23  
ICE23  
ICS45  
ICE45  
ICS67  
ICE67  
OCS0  
OCS1  
OCS2  
OCS3  
OCS4  
OCS5  
OCS6  
OCS7  
000050H Input Capture Control Status 0/1  
000051H Input Capture Edge 0/1  
R/W  
R/W, R  
R/W  
R
00000000B  
XXX0X0XXB  
00000000B  
XXXXXXXXB  
00000000B  
XXXXXXXXB  
00000000B  
XXX000XXB  
0000XX00B  
0XX00000B  
0000XX00B  
0XX00000B  
0000XX00B  
0XX00000B  
0000XX00B  
Input Capture 0/1  
Input Capture 2/3  
Input Capture 4/5  
Input Capture 6/7  
Output Compare 0/1  
Output Compare 2/3  
Output Compare 4/5  
Output Compare 6/7  
000052H Input Capture Control Status 2/3  
000053H Input Capture Edge 2/3  
000054H Input Capture Control Status 4/5  
000055H Input Capture Edge 4/5  
R/W  
R
000056H Input Capture Control Status 6/7  
000057H Input Capture Edge 6/7  
R/W  
R/W, R  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
000058H Output Compare Control Status 0  
000059H Output Compare Control Status 1  
00005AH Output Compare Control Status 2  
00005BH Output Compare Control Status 3  
00005CH Output Compare Control Status 4  
00005DH Output Compare Control Status 5  
00005EH Output Compare Control Status 6  
00005FH Output Compare Control Status 7  
0XX00000B  
(Continued)  
33  
MB90340E Series  
Address  
Register  
Abbreviation Access Resource name Initial value  
000060H Timer Control Status 0  
000061H Timer Control Status 0  
000062H Timer Control Status 1  
000063H Timer Control Status 1  
000064H Timer Control Status 2  
000065H Timer Control Status 2  
000066H Timer Control Status 3  
000067H Timer Control Status 3  
000068H A/D Control Status 0  
000069H A/D Control Status 1  
00006AH A/D Data 0  
TMCSR0  
TMCSR0  
TMCSR1  
TMCSR1  
TMCSR2  
TMCSR2  
TMCSR3  
TMCSR3  
ADCS0  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R
00000000B  
XXXX0000B  
00000000B  
XXXX0000B  
00000000B  
XXXX0000B  
00000000B  
XXXX0000B  
000XXXX0B  
0000000XB  
00000000B  
XXXXXX00B  
00000000B  
00000000B  
16-bit Reload  
Timer 0  
16-bit Reload  
Timer 1  
16-bit Reload  
Timer 2  
16-bit Reload  
Timer 3  
ADCS1  
ADCR0  
A/D Converter  
00006BH A/D Data 1  
ADCR1  
R
00006CH ADC Setting 0  
ADSR0  
R/W  
R/W  
00006DH ADC Setting 1  
ADSR1  
00006EH  
Reserved  
ROMM  
00006FH ROM Mirror Function Select  
000070H  
W
ROM Mirror  
XXXXXXX1B  
to  
Reserved for CAN Controller 0/1. Refer to “CAN CONTROLLERS”  
00008FH  
000090H  
to  
Reserved  
00009AH  
DMA Descriptor Channel Specified  
Register  
00009BH  
DCSR  
R/W  
00000000B  
DMA  
00009CH DMA Status L Register  
00009DH DMA Status H Register  
DSRL  
DSRH  
R/W  
R/W  
00000000B  
00000000B  
Address Match  
Detection 0  
00009EH Address Detect Control Register 0  
PACSR0  
DIRR  
R/W  
R/W  
00000000B  
Delayed Interrupt Trigger/Release  
00009FH  
Register  
Delayed Interrupt XXXXXXX0B  
Low Power  
00011000B  
0000A0H Low-power Mode Control Register  
0000A1H Clock Selection Register  
LPMCR  
CKSCR  
W,R/W  
R,R/W  
Control Circuit  
Low Power  
11111100B  
Control Circuit  
0000A2H,  
0000A3H  
Reserved  
DSSR  
0000A4H DMA Stop Status Register  
R/W  
DMA  
00000000B  
(Continued)  
34  
MB90340E Series  
Address  
Register  
Abbreviation Access Resource name Initial value  
Automatic Ready Function Select  
Register  
0000A5H  
ARSR  
HACR  
W
W
0011XX00B  
External Memory  
Access  
External Address Output Control  
Register  
0000A6H  
00000000B  
0000000XB  
0000A7H Bus Control Signal Selection Register  
0000A8H Watchdog Control Register  
0000A9H Time Base Timer Control Register  
0000AAH Watch Timer Control Register  
0000ABH  
ECSR  
WDTC  
TBTC  
W
R,W  
Watchdog Timer XXXXX111B  
W,R/W Time Base Timer 1XX00100B  
WTC  
R,R/W  
Watch Timer  
1X001000B  
Reserved  
DERL  
0000ACH DMA Enable L Register  
0000ADH DMA Enable H Register  
R/W  
R/W  
00000000B  
00000000B  
DMA  
DERH  
Flash Control Status Register  
0000AEH (Flash memory devices only.  
Otherwise reserved)  
FMCS  
R,R/W  
Flash Memory  
000X0000B  
0000AFH  
Reserved  
ICR00  
ICR01  
ICR02  
ICR03  
ICR04  
ICR05  
ICR06  
ICR07  
ICR08  
ICR09  
ICR10  
ICR11  
ICR12  
ICR13  
ICR14  
ICR15  
DAT0  
0000B0H Interrupt Control Register 00  
0000B1H Interrupt Control Register 01  
0000B2H Interrupt Control Register 02  
0000B3H Interrupt Control Register 03  
0000B4H Interrupt Control Register 04  
0000B5H Interrupt Control Register 05  
0000B6H Interrupt Control Register 06  
0000B7H Interrupt Control Register 07  
0000B8H Interrupt Control Register 08  
0000B9H Interrupt Control Register 09  
0000BAH Interrupt Control Register 10  
0000BBH Interrupt Control Register 11  
0000BCH Interrupt Control Register 12  
0000BDH Interrupt Control Register 13  
0000BEH Interrupt Control Register 14  
0000BFH Interrupt Control Register 15  
0000C0H D/A Converter Data 0  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
W,R/W  
R/W  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
00000111B  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXX0B  
Interrupt Control  
0000C1H D/A Converter Data 1  
DAT1  
R/W  
D/A Converter  
0000C2H D/A Control 0  
DACR0  
DACR1  
R/W  
0000C3H D/A Control 1  
R/W  
XXXXXXX0B  
(Continued)  
35  
MB90340E Series  
Address  
Register  
Abbreviation Access Resource name Initial value  
0000C4H,  
0000C5H  
Reserved  
0000C6H External Interrupt Enable 0  
ENIR0  
EIRR0  
ELVR0  
ELVR0  
ENIR1  
EIRR1  
ELVR1  
ELVR1  
EISSR  
PSCCR  
BAPL  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
W
00000000B  
XXXXXXXXB  
00000000B  
00000000B  
00000000B  
XXXXXXXXB  
0000C7H External Interrupt Source 0  
External Interrupt 0  
0000C8H External Interrupt Level Setting 0  
0000C9H External Interrupt Level Setting 0  
0000CAH External Interrupt Enable 1  
0000CBH External Interrupt Source 1  
0000CCH External Interrupt Level Setting 1  
0000CDH External Interrupt Level Setting 1  
0000CEH External Interrupt Source Select  
0000CFH PLL/Sub clock Control Register  
0000D0H DMA Buffer Address Pointer L Register  
0000D1H DMA Buffer Address Pointer M Register  
0000D2H DMA Buffer Address Pointer H Register  
0000D3H DMA Control Register  
External Interrupt 1 00000000B  
00000000B  
00000000B  
PLL  
XXXX0000B  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
R/W  
R/W  
R/W  
R/W  
BAPM  
BAPH  
DMACS  
I/O Register Address Pointer L  
DMA  
0000D4H  
Register  
IOAL  
IOAH  
R/W  
R/W  
XXXXXXXXB  
XXXXXXXXB  
I/O Register Address Pointer H  
0000D5H  
Register  
0000D6H Data Counter L Register  
0000D7H Data Counter H Register  
0000D8H Serial Mode Register 2  
0000D9H Serial Control Register 2  
DCTL  
DCTH  
SMR2  
SCR2  
R/W  
R/W  
XXXXXXXXB  
XXXXXXXXB  
00000000B  
00000000B  
W,R/W  
W,R/W  
Reception/Transmission Data  
Register 2  
0000DAH  
RDR2/TDR2  
SSR2  
R/W  
00000000B  
00001000B  
000000XXB  
0000DBH Serial Status Register 2  
R,R/W  
UART2  
Extended Communication Control  
Register 2  
R,W,  
R/W  
0000DCH  
ECCR2  
0000DDH Extended Status Control Register 2  
0000DEH Baud Rate Generator Register 20  
0000DFH Baud Rate Generator Register 21  
0000E0H  
ESCR2  
BGR20  
BGR21  
R/W  
R/W  
R/W  
00000100B  
00000000B  
00000000B  
to  
Reserved for CAN Controller 2. Refer to “CAN CONTROLLERS”  
0000EFH  
0000F0H  
to  
External  
0000FFH  
(Continued)  
36  
MB90340E Series  
Address  
Register  
Abbreviation Access  
Resource name  
Initial value  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
007900H Reload Register L0  
007901H Reload Register H0  
007902H Reload Register L1  
007903H Reload Register H1  
007904H Reload Register L2  
007905H Reload Register H2  
007906H Reload Register L3  
007907H Reload Register H3  
007908H Reload Register L4  
007909H Reload Register H4  
00790AH Reload Register L5  
00790BH Reload Register H5  
00790CH Reload Register L6  
00790DH Reload Register H6  
00790EH Reload Register L7  
00790FH Reload Register H7  
007910H Reload Register L8  
007911H Reload Register H8  
007912H Reload Register L9  
007913H Reload Register H9  
007914H Reload Register LA  
007915H Reload Register HA  
007916H Reload Register LB  
007917H Reload Register HB  
007918H Reload Register LC  
007919H Reload Register HC  
00791AH Reload Register LD  
00791BH Reload Register HD  
00791CH Reload Register LE  
00791DH Reload Register HE  
00791EH Reload Register LF  
00791FH Reload Register HF  
007920H Input Capture 0  
PRLL0  
PRLH0  
PRLL1  
PRLH1  
PRLL2  
PRLH2  
PRLL3  
PRLH3  
PRLL4  
PRLH4  
PRLL5  
PRLH5  
PRLL6  
PRLH6  
PRLL7  
PRLH7  
PRLL8  
PRLH8  
PRLL9  
PRLH9  
PRLLA  
PRLHA  
PRLLB  
PRLHB  
PRLLC  
PRLHC  
PRLLD  
PRLHD  
PRLLE  
PRLHE  
PRLLF  
PRLHF  
IPCP0  
IPCP0  
IPCP1  
IPCP1  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R
16-bit PPG 0/1  
16-bit PPG 2/3  
16-bit PPG 4/5  
16-bit PPG 6/7  
16-bit PPG 8/9  
16-bit PPG A/B  
16-bit PPG C/D  
16-bit PPG E/F  
Input Capture 0/1  
007921H Input Capture 0  
R
007922H Input Capture 1  
R
007923H Input Capture 1  
R
XXXXXXXXB  
(Continued)  
37  
MB90340E Series  
Address  
Register  
Abbreviation Access  
Resource name  
Initial value  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
00000000B  
007924H Input Capture 2  
007925H Input Capture 2  
007926H Input Capture 3  
007927H Input Capture 3  
007928H Input Capture 4  
007929H Input Capture 4  
00792AH Input Capture 5  
00792BH Input Capture 5  
00792CH Input Capture 6  
00792DH Input Capture 6  
00792EH Input Capture 7  
00792FH Input Capture 7  
007930H Output Compare 0  
007931H Output Compare 0  
007932H Output Compare 1  
007933H Output Compare 1  
007934H Output Compare 2  
007935H Output Compare 2  
007936H Output Compare 3  
007937H Output Compare 3  
007938H Output Compare 4  
007939H Output Compare 4  
00793AH Output Compare 5  
00793BH Output Compare 5  
00793CH Output Compare 6  
00793DH Output Compare 6  
00793EH Output Compare 7  
00793FH Output Compare 7  
007940H Timer Data 0  
IPCP2  
IPCP2  
R
R
Input Capture 2/3  
IPCP3  
R
IPCP3  
R
IPCP4  
R
IPCP4  
R
Input Capture 4/5  
Input Capture 6/7  
Output Compare 0/1  
Output Compare 2/3  
Output Compare 4/5  
Output Compare 6/7  
I/O Timer 0  
IPCP5  
R
IPCP5  
R
IPCP6  
R
IPCP6  
R
IPCP7  
R
IPCP7  
R
OCCP0  
OCCP0  
OCCP1  
OCCP1  
OCCP2  
OCCP2  
OCCP3  
OCCP3  
OCCP4  
OCCP4  
OCCP5  
OCCP5  
OCCP6  
OCCP6  
OCCP7  
OCCP7  
TCDT0  
TCDT0  
TCCSL0  
TCCSH0  
TCDT1  
TCDT1  
TCCSL1  
TCCSH1  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
007941H Timer Data 0  
00000000B  
007942H Timer Control Status 0  
007943H Timer Control Status 0  
007944H Timer Data 1  
00000000B  
0XXXXXXXB  
00000000B  
007945H Timer Data 1  
00000000B  
I/O Timer 1  
007946H Timer Control Status 1  
007947H Timer Control Status 1  
00000000B  
0XXXXXXXB  
(Continued)  
38  
MB90340E Series  
Address  
007948H  
007949H  
00794AH  
00794BH  
00794CH  
00794DH  
00794EH  
00794FH  
Register  
Timer 0/Reload 0  
Abbreviation Access  
Resource name  
Initial value  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
00000000B  
R/W  
R/W  
TMR0/  
TMRLR0  
16-bit Reload  
Timer 0  
R/W  
TMR1/  
16-bit Reload  
Timer 1  
Timer 1/Reload 1  
Timer 2/Reload 2  
Timer 3/Reload 3  
TMRLR1  
R/W  
R/W  
TMR2/  
16-bit Reload  
Timer 2  
TMRLR2  
R/W  
R/W  
TMR3/  
16-bit Reload  
Timer 3  
TMRLR3  
R/W  
007950H Serial Mode Register 3  
007951H Serial Control Register 3  
SMR3  
SCR3  
W,R/W  
W,R/W  
00000000B  
Reception/Transmission Data  
Register 3  
007952H  
RDR3/TDR3  
SSR3  
R/W  
00000000B  
00001000B  
000000XXB  
007953H Serial Status Register 3  
R,R/W  
UART3  
Extended Communication Control  
Register 3  
R,W,  
R/W  
007954H  
ECCR3  
007955H Extended Status Control Register  
007956H Baud Rate Generator Register 30  
007957H Baud Rate Generator Register 31  
007958H Serial Mode Register 4  
ESCR3  
BGR30  
BGR31  
SMR4  
R/W  
R/W  
00000100B  
00000000B  
00000000B  
00000000B  
00000000B  
R/W  
W,R/W  
W,R/W  
007959H Serial Control Register 4  
SCR4  
Reception/Transmission Data  
Register 4  
00795AH  
RDR4/TDR4  
SSR4  
R/W  
00000000B  
00001000B  
000000XXB  
00795BH Serial Status Register 4  
R,R/W  
UART4  
Extended Communication Control  
Register 4  
R,W,  
R/W  
00795CH  
ECCR4  
00795DH Extended Status Control Register  
00795EH Baud Rate Generator Register 40  
00795FH Baud Rate Generator Register 41  
ESCR4  
BGR40  
BGR41  
R/W  
R/W  
R/W  
00000100B  
00000000B  
00000000B  
007960H  
to  
Reserved  
00796BH  
00796CH Clock Output Enable Register  
00796DH  
CLKR  
Reserved  
R/W  
Clock Monitor  
XXXX0000B  
00796EH CAN Direct Mode Register  
00796FH CAN Switch Register  
CDMR  
R/W  
R/W  
CAN clock sync  
CAN 0/1  
XXXXXXX0B  
XXXXXX00B  
(Continued)  
CANSWR  
39  
MB90340E Series  
Address  
Register  
Abbreviation Access Resource name Initial value  
007970H I2C Bus Status Register 0  
007971H I2C Bus Control Register 0  
007972H  
IBSR0  
IBCR0  
ITBAL0  
ITBAH0  
ITMKL0  
ITMKH0  
ISBA0  
R
W,R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
00000000B  
00000000B  
00000000B  
00000000B  
11111111B  
00111111B  
00000000B  
01111111B  
00000000B  
I2C 10-bit Slave Address Register 0  
007973H  
007974H  
007975H  
I2C Interface 0  
I2C 10-bit Slave Address Mask  
Register 0  
007976H I2C 7-bit Slave Address Register 0  
007977H I2C 7-bit Slave Address Mask Register 0  
007978H I2C Data Register 0  
ISMK0  
IDAR0  
007979H,  
00797AH  
Reserved  
ICCR0  
00797BH I2C Clock Control Register 0  
R/W  
I2C Interface 0  
00011111B  
00797CH  
to  
Reserved  
00797FH  
007980H I2C Bus Status Register 1  
007981H I2C Bus Control Register 1  
IBSR1  
IBCR1  
ITBAL1  
ITBAH1  
ITMKL1  
ITMKH1  
ISBA1  
R
W,R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
00000000B  
00000000B  
00000000B  
00000000B  
11111111B  
00111111B  
00000000B  
01111111B  
00000000B  
007982H  
I2C 10-bit Slave Address Register 1  
007983H  
007984H  
I2C Interface 1  
I2C 10-bit Slave Address Mask  
Register 1  
007985H  
007986H I2C 7-bit Slave Address Register 1  
007987H I2C 7-bit Slave Address Mask Register 1  
007988H I2C Data Register 1  
ISMK1  
IDAR1  
007989H,  
00798AH  
Reserved  
ICCR1  
00798BH I2C Clock Control Register 1  
R/W  
I2C Interface 1  
00011111B  
00798CH  
to  
Reserved  
0079C1H  
Clock Modulator Control Register  
CMCR  
0079C2H  
Clock Modulator  
0079C3H  
to  
Reserved  
0079DFH  
(Continued)  
40  
MB90340E Series  
(Continued)  
Address  
Register  
Abbreviation Access  
Resource name  
Initial value  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
0079E0H Detect Address Setting 0  
0079E1H Detect Address Setting 0  
0079E2H Detect Address Setting 0  
0079E3H Detect Address Setting 1  
0079E4H Detect Address Setting 1  
0079E5H Detect Address Setting 1  
0079E6H Detect Address Setting 2  
0079E7H Detect Address Setting 2  
0079E8H Detect Address Setting 2  
PADR0  
PADR0  
PADR0  
PADR1  
PADR1  
PADR1  
PADR2  
PADR2  
PADR2  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Address Match  
Detection 0  
0079E9H  
to  
Reserved  
0079EFH  
0079F0H Detect Address Setting 3  
0079F1H Detect Address Setting 3  
0079F2H Detect Address Setting 3  
0079F3H Detect Address Setting 4  
0079F4H Detect Address Setting 4  
0079F5H Detect Address Setting 4  
0079F6H Detect Address Setting 5  
0079F7H Detect Address Setting 5  
0079F8H Detect Address Setting 5  
PADR3  
PADR3  
PADR3  
PADR4  
PADR4  
PADR4  
PADR5  
PADR5  
PADR5  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
Address Match  
Detection 1  
0079F9H  
to  
Reserved  
0079FFH  
007A00H  
to  
Reserved for CAN Controller 0. Refer to “CAN CONTROLLERS”  
Reserved for CAN Controller 0. Refer to “CAN CONTROLLERS”  
Reserved for CAN Controller 1. Refer to “CAN CONTROLLERS”  
Reserved for CAN Controller 1. Refer to “CAN CONTROLLERS”  
Reserved for CAN Controller 2. Refer to “CAN CONTROLLERS”  
Reserved for CAN Controller 2. Refer to “CAN CONTROLLERS”  
007AFFH  
007B00H  
to  
007BFFH  
007C00H  
to  
007CFFH  
007D00H  
to  
007DFFH  
007E00H  
to  
007EFFH  
007F00H  
to  
007FFFH  
Notes : Initial value of “X” represents unknown value.  
Any write access to reserved addresses in I/O map should not be performed. A read access to reserved  
addresses results in reading “X”.  
41  
MB90340E Series  
CAN CONTROLLERS  
The CAN controller has the following features:  
• Conforms to CAN Specification Version 2.0 Part A and B  
Supports transmission/reception in standard frame and extended frame formats  
• Supports transmission of data frames by receiving remote frames  
• 16 transmission/reception message buffers  
29-bit ID and 8-byte data  
Multi-level message buffer configuration  
• Provides full-bit comparison, full-bit mask, acceptance register 0/acceptance register 1 for each message  
buffer as ID acceptance mask  
Two acceptance mask registers in either standard frame format or extended frame formats  
• Bit rate programmable from 10 kbps to 2 Mbps (when input clock is at 16 MHz)  
List of Control Registers (1)  
Address  
Register  
Abbreviation Access  
Initial Value  
CAN0  
CAN1  
CAN2  
000070H  
000071H  
000072H  
000073H  
000074H  
000075H  
000076H  
000077H  
000078H  
000079H  
00007AH  
00007BH  
00007CH  
00007DH  
00007EH  
00007FH  
000080H  
000081H  
000082H  
000083H  
000084H  
000085H  
000086H  
000087H  
000088H  
000089H  
00008AH  
00008BH  
00008CH  
00008DH  
00008EH  
00008FH  
0000E0H  
0000E1H  
0000E2H  
0000E3H  
0000E4H  
0000E5H  
0000E6H  
0000E7H  
0000E8H  
0000E9H  
0000EAH  
0000EBH  
0000ECH  
0000EDH  
0000EEH  
0000EFH  
Message Buffer  
Valid Register  
00000000B  
00000000B  
BVALR  
TREQR  
TCANR  
TCR  
R/W  
R/W  
W
Transmit Request  
Register  
00000000B  
00000000B  
Transmit Cancel  
Register  
00000000B  
00000000B  
Transmission  
Complete Register  
00000000B  
00000000B  
R/W  
R/W  
R/W  
R/W  
R/W  
Receive Complete  
Register  
00000000B  
00000000B  
RCR  
Remote Request  
Receiving Register  
00000000B  
00000000B  
RRTRR  
ROVRR  
RIER  
Receive Overrun  
Register  
00000000B  
00000000B  
Reception Interrupt  
Enable Register  
00000000B  
00000000B  
42  
MB90340E Series  
List of Control Registers (2)  
Register  
Address  
CAN1  
Abbreviation Access  
Initial Value  
CAN0  
CAN2  
007B00H  
007B01H  
007B02H  
007B03H  
007B04H  
007B05H  
007B06H  
007B07H  
007B08H  
007B09H  
007B0AH  
007B0BH  
007B0CH  
007D00H  
007D01H  
007D02H  
007D03H  
007D04H  
007D05H  
007D06H  
007D07H  
007D08H  
007D09H  
007D0AH  
007D0BH  
007D0CH  
007F00H  
007F01H  
007F02H  
007F03H  
007F04H  
007F05H  
007F06H  
007F07H  
007F08H  
007F09H  
007F0AH  
007F0BH  
007F0CH  
Control Status  
R/W, W  
R/W, R  
0XXXX0X1B  
00XXX000B  
CSR  
Register  
Last Event  
Indicator Register  
000X0000B  
XXXXXXXXB  
LEIR  
RTEC  
BTR  
R/W  
R
Receive And Transmit  
Error Counter  
00000000B  
00000000B  
Bit Timing  
Register  
11111111B  
X1111111B  
R/W  
R/W  
R/W  
XXXXXXXXB  
XXXXXXXXB  
IDE Register  
IDER  
Transmit RTR  
Register  
00000000B  
00000000B  
TRTRR  
Remote Frame  
Receive Waiting  
Register  
XXXXXXXXB  
XXXXXXXXB  
RFWTR  
TIER  
R/W  
R/W  
007B0DH  
007D0DH  
007F0DH  
007B0EH  
007B0FH  
007B10H  
007B11H  
007B12H  
007B13H  
007B14H  
007B15H  
007B16H  
007B17H  
007B18H  
007B19H  
007B1AH  
007B1BH  
007D0EH  
007D0FH  
007D10H  
007D11H  
007D12H  
007D13H  
007D14H  
007D15H  
007D16H  
007D17H  
007D18H  
007D19H  
007D1AH  
007D1BH  
007F0EH  
007F0FH  
007F10H  
007F11H  
007F12H  
007F13H  
007F14H  
007F15H  
007F16H  
007F17H  
007F18H  
007F19H  
007F1AH  
007F1BH  
Transmit Interrupt  
Enable Register  
00000000B  
00000000B  
XXXXXXXXB  
XXXXXXXXB  
Acceptance Mask  
Select Register  
AMSR  
AMR0  
AMR1  
R/W  
R/W  
R/W  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
Acceptance Mask  
Register 0  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
Acceptance Mask  
Register 1  
XXXXXXXXB  
XXXXXXXXB  
43  
MB90340E Series  
List of Message Buffers (ID Registers) (1)  
Address  
CAN1  
Register  
Abbreviation  
Access  
Initial Value  
CAN0  
CAN2  
007A00H  
to  
007A1FH  
007C00H  
to  
007C1FH  
007E00H  
to  
007E1FH  
XXXXXXXXB  
to  
XXXXXXXXB  
General-  
Purpose Ram  
R/W  
007A20H  
007A21H  
007A22H  
007A23H  
007A24H  
007A25H  
007A26H  
007A27H  
007A28H  
007A29H  
007A2AH  
007A2BH  
007A2CH  
007A2DH  
007A2EH  
007A2FH  
007A30H  
007A31H  
007A32H  
007A33H  
007A34H  
007A35H  
007A36H  
007A37H  
007A38H  
007A39H  
007A3AH  
007A3BH  
007A3CH  
007A3DH  
007A3EH  
007A3FH  
007C20H  
007C21H  
007C22H  
007C23H  
007C24H  
007C25H  
007C26H  
007C27H  
007C28H  
007C29H  
007C2AH  
007C2BH  
007C2CH  
007C2DH  
007C2EH  
007C2FH  
007C30H  
007C31H  
007C32H  
007C33H  
007C34H  
007C35H  
007C36H  
007C37H  
007C38H  
007C39H  
007C3AH  
007C3BH  
007C3CH  
007C3DH  
007C3EH  
007C3FH  
007E20H  
007E21H  
007E22H  
007E23H  
007E24H  
007E25H  
007E26H  
007E27H  
007E28H  
007E29H  
007E2AH  
007E2BH  
007E2CH  
007E2DH  
007E2EH  
007E2FH  
007E30H  
007E31H  
007E32H  
007E33H  
007E34H  
007E35H  
007E36H  
007E37H  
007E38H  
007E39H  
007E3AH  
007E3BH  
007E3CH  
007E3DH  
007E3EH  
007E3FH  
XXXXXXXXB  
XXXXXXXXB  
Id Register 0  
Id Register 1  
Id Register 2  
Id Register 3  
Id Register 4  
Id Register 5  
Id Register 6  
Id Register 7  
IDR0  
IDR1  
IDR2  
IDR3  
IDR4  
IDR5  
IDR6  
IDR7  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
44  
MB90340E Series  
List of Message Buffers (ID Registers) (2)  
Address  
CAN1  
Register  
Abbreviation  
Access  
Initial Value  
CAN0  
CAN2  
007A40H  
007A41H  
007A42H  
007A43H  
007A44H  
007A45H  
007A46H  
007A47H  
007A48H  
007A49H  
007A4AH  
007A4BH  
007A4CH  
007A4DH  
007A4EH  
007A4FH  
007A50H  
007A51H  
007A52H  
007A53H  
007A54H  
007A55H  
007A56H  
007A57H  
007A58H  
007A59H  
007A5AH  
007A5BH  
007A5CH  
007A5DH  
007A5EH  
007A5FH  
007C40H  
007C41H  
007C42H  
007C43H  
007C44H  
007C45H  
007C46H  
007C47H  
007C48H  
007C49H  
007C4AH  
007C4BH  
007C4CH  
007C4DH  
007C4EH  
007C4FH  
007C50H  
007C51H  
007C52H  
007C53H  
007C54H  
007C55H  
007C56H  
007C57H  
007C58H  
007C59H  
007C5AH  
007C5BH  
007C5CH  
007C5DH  
007C5EH  
007C5FH  
007E40H  
007E41H  
007E42H  
007E43H  
007E44H  
007E45H  
007E46H  
007E47H  
007E48H  
007E49H  
007E4AH  
007E4BH  
007E4CH  
007E4DH  
007E4EH  
007E4FH  
007E50H  
007E51H  
007E52H  
007E53H  
007E54H  
007E55H  
007E56H  
007E57H  
007E58H  
007E59H  
007E5AH  
007E5BH  
007E5CH  
007E5DH  
007E5EH  
007E5FH  
XXXXXXXXB  
XXXXXXXXB  
Id Register 8  
IDR8  
R/W  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
Id Register 9  
Id Register 10  
Id Register 11  
Id Register 12  
Id Register 13  
Id Register 14  
Id Register 15  
IDR9  
IDR10  
IDR11  
IDR12  
IDR13  
IDR14  
IDR15  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
45  
MB90340E Series  
List of Message Buffers (DLC Registers and Data Registers) (1)  
Address  
CAN1  
Register  
Abbreviation  
DLCR0  
Access  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
Initial Value  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
XXXXXXXXB  
CAN0  
CAN2  
007A60H  
007A61H  
007A62H  
007A63H  
007A64H  
007A65H  
007A66H  
007A67H  
007A68H  
007A69H  
007A6AH  
007A6BH  
007A6CH  
007A6DH  
007A6EH  
007A6FH  
007A70H  
007A71H  
007A72H  
007A73H  
007A74H  
007A75H  
007A76H  
007A77H  
007A78H  
007A79H  
007A7AH  
007A7BH  
007A7CH  
007A7DH  
007A7EH  
007A7FH  
007C60H  
007C61H  
007C62H  
007C63H  
007C64H  
007C65H  
007C66H  
007C67H  
007C68H  
007C69H  
007C6AH  
007C6BH  
007C6CH  
007C6DH  
007C6EH  
007C6FH  
007C70H  
007C71H  
007C72H  
007C73H  
007C74H  
007C75H  
007C76H  
007C77H  
007C78H  
007C79H  
007C7AH  
007C7BH  
007C7CH  
007C7DH  
007C7EH  
007C7FH  
007E60H  
007E61H  
007E62H  
007E63H  
007E64H  
007E65H  
007E66H  
007E67H  
007E68H  
007E69H  
007E6AH  
007E6BH  
007E6CH  
007E6DH  
007E6EH  
007E6FH  
007E70H  
007E71H  
007E72H  
007E73H  
007E74H  
007E75H  
007E76H  
007E77H  
007E78H  
007E79H  
007E7AH  
007E7BH  
007E7CH  
007E7DH  
007E7EH  
007E7FH  
DLC Register 0  
DLC Register 1  
DLC Register 2  
DLC Register 3  
DLC Register 4  
DLC Register 5  
DLC Register 6  
DLC Register 7  
DLC Register 8  
DLC Register 9  
DLC Register 10  
DLC Register 11  
DLC Register 12  
DLC Register 13  
DLC Register 14  
DLC Register 15  
DLCR1  
DLCR2  
DLCR3  
DLCR4  
DLCR5  
DLCR6  
DLCR7  
DLCR8  
DLCR9  
DLCR10  
DLCR11  
DLCR12  
DLCR13  
DLCR14  
DLCR15  
46  
MB90340E Series  
List of Message Buffers (DLC Registers and Data Registers) (2)  
Address  
CAN1  
Register  
Abbreviation  
Access  
Initial Value  
CAN0  
CAN2  
007A80H  
to  
007A87H  
007C80H  
to  
007C87H  
007E80H  
to  
007E87H  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 0  
(8 bytes)  
DTR0  
R/W  
007A88H  
to  
007A8FH  
007C88H  
to  
007C8FH  
007E88H  
to  
007E8FH  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 1  
(8 bytes)  
DTR1  
DTR2  
DTR3  
DTR4  
DTR5  
DTR6  
DTR7  
DTR8  
DTR9  
DTR10  
DTR11  
DTR12  
DTR13  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
R/W  
007A90H  
to  
007A97H  
007C90H  
to  
007C97H  
007E90H  
to  
007E97H  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 2  
(8 bytes)  
007A98H  
to  
007A9FH  
007C98H  
to  
007C9FH  
007E98H  
to  
007E9FH  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 3  
(8 bytes)  
007AA0H  
to  
007AA7H  
007CA0H  
to  
007CA7H  
007EA0H  
to  
007EA7H  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 4  
(8 bytes)  
007AA8H  
to  
007AAFH  
007CA8H  
to  
007CAFH  
007EA8H  
to  
007EAFH  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 5  
(8 bytes)  
007AB0H  
to  
007AB7H  
007CB0H  
to  
007CB7H  
007EB0H  
to  
007EB7H  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 6  
(8 bytes)  
007AB8H  
to  
007ABFH  
007CB8H  
to  
007CBFH  
007EB8H  
to  
007EBFH  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 7  
(8 bytes)  
007AC0H  
to  
007AC7H  
007CC0H  
to  
007CC7H  
007EC0H  
to  
007EC7H  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 8  
(8 bytes)  
007AC8H  
to  
007ACFH  
007CC8H  
to  
007CCFH  
007EC8H  
to  
007ECFH  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 9  
(8 bytes)  
007AD0H  
to  
007AD7H  
007CD0H  
to  
007CD7H  
007ED0H  
to  
007ED7H  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 10  
(8 bytes)  
007AD8H  
to  
007ADFH  
007CD8H  
to  
007CDFH  
007ED8H  
to  
007EDFH  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 11  
(8 bytes)  
007AE0H  
to  
007AE7H  
007CE0H  
to  
007CE7H  
007EE0H  
to  
007EE7H  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 12  
(8 bytes)  
007AE8H  
to  
007AEFH  
007CE8H  
to  
007CEFH  
007EE8H  
to  
007EEFH  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 13  
(8 bytes)  
47  
MB90340E Series  
List of Message Buffers (DLC Registers and Data Registers) (3)  
Address  
CAN1  
Register  
Abbreviation  
Access  
Initial Value  
CAN0  
CAN2  
007AF0H  
to  
007AF7H  
007CF0H  
to  
007CF7H  
007EF0H  
to  
007EF7H  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 14  
(8 bytes)  
DTR14  
R/W  
007AF8H  
to  
007AFFH  
007CF8H  
to  
007CFFH  
007EF8H  
to  
007EFFH  
XXXXXXXXB  
to  
XXXXXXXXB  
Data Register 15  
(8 bytes)  
DTR15  
R/W  
48  
MB90340E Series  
INTERRUPT FACTORS, INTERRUPT VECTORS, INTERRUPT CONTROL REGISTER  
Interrupt control  
DMA  
channel  
number  
Interrupt vector  
Number Address  
EI2OS  
Support  
register  
Interrupt cause  
Number  
Address  
Reset  
N
N
0
#08  
#09  
#10  
#11  
#12  
#13  
#14  
#15  
#16  
#17  
#18  
#19  
#20  
#21  
#22  
#23  
#24  
#25  
#26  
#27  
#28  
#29  
#30  
#31  
#32  
#33  
#34  
#35  
#36  
#37  
#38  
FFFFDCH  
FFFFD8H  
FFFFD4H  
FFFFD0H  
FFFFCCH  
FFFFC8H  
FFFFC4H  
FFFFC0H  
FFFFBCH  
FFFFB8H  
FFFFB4H  
FFFFB0H  
FFFFACH  
FFFFA8H  
FFFFA4H  
FFFFA0H  
FFFF9CH  
FFFF98H  
FFFF94H  
FFFF90H  
FFFF8CH  
FFFF88H  
FFFF84H  
FFFF80H  
FFFF7CH  
FFFF78H  
FFFF74H  
FFFF70H  
FFFF6CH  
FFFF68H  
FFFF64H  
INT9 instruction  
Exception  
N
CAN 0 RX  
N
ICR00  
ICR01  
ICR02  
ICR03  
ICR04  
ICR05  
ICR06  
ICR07  
ICR08  
ICR09  
ICR10  
ICR11  
ICR12  
ICR13  
0000B0H  
0000B1H  
0000B2H  
0000B3H  
0000B4H  
0000B5H  
0000B6H  
0000B7H  
0000B8H  
0000B9H  
0000BAH  
0000BBH  
0000BCH  
CAN 0 TX/NS  
N
CAN 1 RX / Input Capture 6  
CAN 1 TX/NS / Input Capture 7  
CAN 2 RX / I2C0  
Y1  
Y1  
N
CAN 2 TX/NS  
N
16-bit Reload Timer 0  
16-bit Reload Timer 1  
16-bit Reload Timer 2  
16-bit Reload Timer 3  
PPG 0/1/4/5  
Y1  
Y1  
Y1  
Y1  
N
1
2
3
PPG 2/3/6/7  
N
PPG 8/9/C/D  
N
PPG A/B/E/F  
N
Time Base Timer  
N
External Interrupt 0 to 3, 8 to 11  
Watch Timer  
Y1  
N
4
External Interrupt 4 to 7, 12 to 15  
A/D Converter  
Y1  
Y1  
N
5
I/O Timer 0 / I/O Timer 1  
Input Capture 4/5 / I2C1  
Output Compare 0/1/4/5  
Input Capture 0 to 3  
Output Compare 2/3/6/7  
UART 0 RX  
6
Y1  
Y1  
Y1  
Y1  
Y2  
Y1  
Y2  
Y1  
7
8
9
10  
11  
12  
13  
UART 0 TX  
UART 1 RX / UART 3 RX  
UART 1 TX / UART 3 TX  
0000BDH  
(Continued)  
49  
MB90340E Series  
(Continued)  
Interrupt control  
register  
DMA  
channel  
number  
Interrupt vector  
Number Address  
EI2OS  
Support  
Interrupt cause  
Number  
Address  
UART 2 RX / UART 4 RX  
UART 2 TX / UART 4 TX  
Flash Memory  
Y2  
Y1  
N
14  
15  
#39  
#40  
#41  
#42  
FFFF60H  
FFFF5CH  
FFFF58H  
FFFF54H  
ICR14  
0000BEH  
ICR15  
0000BFH  
Delayed Interrupt  
N
Y1 : Usable  
Y2 : Usable, with EI2OS stop function  
N : Unusable  
Notes : The peripheral resources sharing the ICR register have the same interrupt level.  
When two peripheral resources share the ICR register, only one can use Extended Intelligent I/O Service  
at a time.  
When either of the two peripheral resources sharing the ICR register specifies Extended Intelligent I/O  
Service, the other one cannot use interrupts.  
50  
MB90340E Series  
ELECTRICAL CHARACTERISTICS  
1. Absolute Maximum Ratings  
Rating  
Parameter  
Symbol  
Unit  
Remarks  
Min  
Max  
VCC  
VSS 0.3 VSS + 6.0  
VSS 0.3 VSS + 6.0  
V
V
AVCC  
VCC = AVCC*2  
Power supply voltage*1  
AVRH,  
AVRL  
AVCC AVRH, AVCC AVRL,  
AVRH AVRL  
VSS 0.3 VSS + 6.0  
V
Input voltage*1  
Output voltage*1  
VI  
VO  
VSS 0.3 VSS + 6.0  
VSS 0.3 VSS + 6.0  
V
V
*3  
*3  
Maximum Clamp Current  
ICLAMP  
Σ|ICLAMP|  
IOL  
4.0  
+4.0  
40  
mA *5  
mA *5  
mA *4  
mA *4  
mA *4  
mA *4  
mA *4  
mA *4  
mA *4  
mA *4  
mW MB90F347E  
°C  
Total Maximum Clamp Current  
“L” level maximum output current  
“L” level average output current  
“L” level maximum overall output current  
“L” level average overall output current  
“H” level maximum output current  
“H” level average output current  
“H” level maximum overall output current  
“H” level average overall output current  
Power consumption  
15  
IOLAV  
ΣIOL  
4
100  
50  
ΣIOLAV  
IOH  
15  
4  
IOHAV  
ΣIOH  
ΣIOHAV  
PD  
100  
50  
340  
+105  
+150  
Operating temperature  
TA  
40  
55  
Storage temperature  
TSTG  
°C  
*1: This parameter is based on VSS = AVSS = 0 V  
*2: Set AVCC and VCC to the same voltage. Make sure that AVCC does not exceed VCC and that the voltage at the  
analog inputs does not exceed AVCC when the power is switched on.  
*3: VI and VO should not exceed VCC + 0.3 V. VI should not exceed the specified ratings. However if the maximum  
current to/from an input is limited by some means with external components, the ICLAMP rating supersedes the VI  
rating.  
*4: Applicable to pins: P00 to P07, P10 to P17, P20 to P27, P30 to P37, P40 to P47, P50 to P57, P60 to P67,  
P70 to P77, P80 to P87, P90 to P97, PA0, PA1  
*5: Applicable to pins: P00 to P07, P10 to P17, P20 to P27, P30 to P37, P40 to P47,  
P50 to P57 (Evaluation device : P50 to P55) , P60 to P67, P70 to P77, P80 to P87,  
P90 to P97, PA0 to PA1  
Use within recommended operating conditions.  
Use with DC voltage (current)  
The +B signal should always be applied by using a limiting resistance placed between the +B signal and the  
microcontroller.  
The value of the limiting resistance should be set so that when the +B signal is applied, the input current to  
the microcontroller pin does not exceed the rated value, either instantaneously or for prolonged periods.  
Note that when the microcontroller drive current is low, such as in the power saving modes, the +B input  
potential may pass through the protective diode and increase the potential at the VCC pin, and this may affect  
other devices.  
(Continued)  
51  
MB90340E Series  
(Continued)  
Note that if a +B signal is input when the microcontroller power supply is off (not fixed at 0 V) , the power  
supply is provided from the pins, so that incomplete operation may result.  
Note that if the +B input is applied during power-on, the power supply is provided from the pins and the  
resulting supply voltage may not be sufficient to operate the power-on reset.  
Care must be taken not to leave the +B input pin open.  
Sample recommended circuits:  
• Input/output equivalent circuits  
Protective diode  
VCC  
Limiting  
resistance  
P-ch  
+B input (0 V to 16 V)  
N-ch  
R
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,  
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.  
52  
MB90340E Series  
2. Recommended Operating Conditions  
(VSS = AVSS = 0 V)  
Remarks  
Value  
Typ  
Parameter  
Symbol  
Unit  
Min  
Max  
4.0  
5.0  
5.5  
V
Under normal operation  
Under normal operation, when not using  
the A/D converter and not Flash  
programming.  
3.5  
5.0  
5.5  
V
VCC,  
AVCC  
Power supply voltage  
4.5  
3.0  
5.0  
5.5  
5.5  
V
V
When External bus is used.  
Maintains RAM data in stop mode  
Use a ceramic capacitor or capacitor of  
better AC characteristics. Capacitor at  
the VCC should be greater than this  
capacitor.  
Smoothing capacitor  
CS  
0.1  
1.0  
µF  
°C  
Operating temperature  
TA  
40  
+105  
C Pin Connection Diagram  
C
CS  
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the  
semiconductor device. All of the device’s electrical characteristics are warranted when the device is  
operated within these ranges.  
Always use semiconductor devices within their recommended operating condition ranges. Operation  
outside these ranges may adversely affect reliability and could result in device failure.  
No warranty is made with respect to uses, operating conditions, or combinations not represented on  
the data sheet. Users considering application outside the listed conditions are advised to contact their  
FUJITSU representatives beforehand.  
53  
MB90340E Series  
3. DC Characteristics  
Sym-  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, fCP 24 MHz, VSS = AVSS = 0 V)  
Value  
Parameter  
Pin  
Condition  
Unit  
Remarks  
bol  
Min  
Typ  
Max  
Port inputs if CMOS  
hysteresis input levels are  
selected (except P12, P44,  
P45, P46, P47, P50, P82,  
P83)  
VIHS  
0.8 VCC  
VCC + 0.3  
V
Port inputs if  
Automotive input levels are  
selected  
VIHA  
VIHT  
VIHS  
0.8 VCC  
2.0  
VCC + 0.3  
VCC + 0.3  
VCC + 0.3  
V
V
V
Input H  
voltage  
(At VCC =  
5 V 10%)  
Port inputs if TTL input levels  
are selected  
P12, P50, P82, P85  
inputs if CMOS input levels  
are selected  
0.7 VCC  
P44, P45, P46, P47  
inputs if CMOS hysteresis  
input levels are selected  
VIHI  
0.7 VCC  
VCC + 0.3  
V
RST input pin  
(CMOS hysteresis)  
VIHR  
VIHM  
0.8 VCC  
VCC + 0.3  
VCC + 0.3  
V
V
VCC 0.3  
MD input pin  
Port inputs if CMOS  
hysteresis input levels are  
selected (except P12, P44,  
P45, P46, P47, P50, P82,  
P83)  
VILS  
VSS 0.3  
0.2 VCC  
V
Port inputs if  
Automotive input levels are  
selected  
VILA  
VILT  
VILS  
VSS 0.3  
VSS 0.3  
VSS 0.3  
0.5 VCC  
0.8  
V
V
V
Input L  
voltage  
(At VCC =  
5 V 10%)  
Port inputs if TTL  
input levels are selected  
P12, P50, P82, P85  
inputs if CMOS input levels  
are selected  
0.3 VCC  
P44, P45, P46, P47  
inputs if CMOS hysteresis  
input levels are selected  
VILI  
VSS 0.3  
0.3 VCC  
V
RST input pin  
(CMOS hysteresis)  
VILR  
VILM  
VOH  
Normal  
outputs  
I2Ccurrent VCC = 4.5 V,  
outputs  
VSS 0.3  
VSS 0.3  
VCC 0.5  
0.2 VCC  
VSS + 0.3  
V
V
V
MD input pin  
Output H  
voltage  
VCC = 4.5 V,  
IOH = −4.0 mA  
Output H  
voltage  
VOHI  
VOL  
VOLI  
VCC 0.5  
V
V
V
IOH = −3.0 mA  
VCC = 4.5 V,  
IOL = 4.0 mA  
Output L  
voltage  
Normal  
outputs  
I2Ccurrent VCC = 4.5 V,  
outputs IOL = 3.0 mA  
0.4  
0.4  
Output L  
voltage  
(Continued)  
54  
MB90340E Series  
(Continued)  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, fCP 24 MHz, VSS = AVSS = 0 V)  
Value  
Sym-  
bol  
Parameter  
Pin  
Condition  
Unit Remarks  
Min Typ Max  
Input leak current  
IIL  
VCC = 5.5 V, VSS < VI < VCC  
1  
+1  
µA  
P00 to P07,  
P10 to P17,  
P20 to P27,  
P30 to P37,  
RST  
Pull-up  
resistance  
RUP  
25  
50  
100 kΩ  
100 kΩ  
Except  
Flash  
memory  
devices  
Pull-down  
resistance  
RDOWN  
MD2  
25  
50  
VCC = 5.0 V,  
Internal frequency : 24 MHz,  
At normal operation.  
55  
70  
75  
25  
0.3  
70  
85  
90  
35  
0.8  
mA  
VCC = 5.0 V,  
Internal frequency : 24 MHz,  
At writing Flash memory.  
Flash  
ICC  
mA memory  
devices  
VCC = 5.0 V,  
Internal frequency : 24 MHz,  
At erasing Flash memory.  
Flash  
mA memory  
devices  
VCC = 5.0 V,  
Internal frequency : 24 MHz,  
In Sleep mode.  
ICCS  
mA  
mA  
VCC = 5.0 V,  
Internal frequency : 2 MHz,  
In Main Timer mode  
ICTS  
VCC = 5.0 V,  
Power supply  
current*  
Internal frequency : 24 MHz,  
In PLL Timer mode,  
external frequency = 4 MHz  
VCC  
ICTSPLL6  
4
7
mA  
VCC = 5.0 V  
Internal frequency : 8 kHz,  
In sub operation  
TA = +25°C  
VCC = 5.0 V  
Internal frequency : 8 kHz,  
In sub sleep  
ICCL  
70  
20  
140 µA  
ICCLS  
50  
µA  
TA = +25°C  
VCC = 5.0 V  
Internal frequency : 8 kHz,  
In watch mode  
TA = +25°C  
VCC = 5.0 V,  
In Stop mode,  
TA = +25°C  
ICCT  
ICCH  
CIN  
10  
7
35  
25  
15  
µA  
µA  
pF  
Other than C,  
AVCC, AVSS,  
AVRH,AVRL,  
VCC, VSS  
Input capacitance  
5
* : The power supply current is measured with an external clock.  
55  
MB90340E Series  
4. AC Characteristics  
(1) Clock Timing  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, fCP 24 MHz, VSS = AVSS = 0 V)  
Value  
Parameter  
Symbol  
Pin  
Unit  
Remarks  
Min  
Typ  
Max  
When using an oscillation  
circuit  
X0, X1  
3
16  
MHz  
fC  
Clock frequency  
When using an external  
clock*  
X0, X1  
X0A, X1A  
X0, X1  
3
24  
MHz  
kHz  
ns  
fCL  
32.768 100  
When using an oscillation  
circuit  
62.5  
333  
333  
tCYL  
Clock cycle time  
When using an external  
clock  
X0, X1  
41.67  
ns  
tCYLL  
PWH, PWL  
PWHL, PWLL  
tCR, tCF  
fCP  
X0A, X1A  
10  
10  
30.5  
5
µs  
ns  
µs  
ns  
X0  
X0A  
X0  
Duty ratio is about 30% to  
70%.  
Input clock pulse width  
5
15.2  
Input clock rise and fall time  
When using external clock  
1.5  
24  
50  
666  
MHz When using main clock  
kHz When using sub clock  
Internal operating clock  
frequency (machine clock)  
fCPL  
8.192  
tCP  
41.67  
20  
ns  
When using main clock  
When using sub clock  
Internal operating clock  
cycle time (machine clock)  
tCPL  
122.1  
µs  
* : When selecting the PLL clock, the range of clock frequency is limited. Use this product within the range as  
mentioned in “Relation between the external clock frequency and machine clock frequency”.  
Clock Timing  
t
CYL  
0.8 VCC  
0.2 VCC  
X0  
P
WH  
PWL  
t
CF  
tCR  
t
CYLL  
0.8 VCC  
0.2 VCC  
X0A  
P
WHL  
PWLL  
t
CF  
tCR  
56  
MB90340E Series  
Guaranteed PLL operation range  
Guaranteed operation range  
5.5  
4.0  
Guaranteed A/D Converter  
operation range  
3.5  
Guaranteed PLL operation range  
1.5  
24  
4
Machine clock fCP (MHz)  
Guaranteed operation range of MB90340E series  
Guaranteed oscillation frequency range  
x 2  
x 1  
x 6 x 4  
x 3  
24  
16  
12  
x 1/2  
(PLL off)  
8
4.0  
1.5  
12  
16  
3
8
4
24  
External clock fC (MHz) *  
* : When using a crystal oscillator or ceramic oscillator, the maximum oscillation clock frequency is 16 MHz  
57  
MB90340E Series  
(2) Reset Standby Input  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, fCP 24 MHz, VSS = AVSS = 0.0 V)  
Value  
Min  
Parameter Symbol  
Pin  
Unit  
Remarks  
Max  
500  
ns  
Under normal operation  
In Stop mode, Sub Clock  
mode, Sub Sleep mode  
and Watch mode  
Reset input  
tRSTL  
Oscillation time of oscillator*  
RST  
ns  
time  
+ 100 µs  
100  
µs  
In Time Timer mode  
* : The oscillation time of the oscillator is the time it takes for the amplitude of the oscillations to reach 90%. For  
crystal oscillators, this time is between several ms and several tens of ms, for ceramic oscillators the time is  
between several hundred µs and several ms, and for an external clock, the time is 0 ms.  
Under normal operation:  
tRSTL  
RST  
0.2 VCC  
0.2 VCC  
In Stop mode, Sub Clock mode, Sub Sleep mode, Watch mode:  
tRSTL  
RST  
0.2 VCC  
0.2 VCC  
90% of  
amplitude  
X0  
Internal operation  
clock  
100 µs  
Oscillation time  
of oscillator  
Oscillation stabilization  
waiting time  
Instruction execution  
Internal reset  
58  
MB90340E Series  
(3) Power On Reset  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, fCP 24 MHz, VSS = AVSS = 0.0 V)  
Value  
Parameter  
Symbol  
Pin  
Condition  
Unit  
Remarks  
Min  
0.05  
1
Max  
30  
Power on rise time  
Power off time  
tR  
VCC  
VCC  
ms  
tOFF  
ms Due to repetitive operation  
tR  
2.7 V  
VCC  
0.2 V  
0.2 V  
0.2 V  
tOFF  
If you change the power supply voltage too rapidly, a power on reset may occur.  
We recommend that you startup smoothly by restraining voltages when changing  
the power supply voltage during operation, as shown in the figure below. Perform  
while not using the PLL clock. However, if voltage drops are within 1 V/s, you can  
operate while using the PLL clock.  
VCC  
We recommend a rise of  
50 mV/ms maximum.  
3 V  
Holds RAM data  
VSS  
(4) Clock Output Timing  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, VSS = 0.0 V, fCP 24 MHz)  
Value  
Parameter  
Symbol  
Pin  
CLK  
CLK  
Condition  
Unit  
Remarks  
Min  
62.5  
41.76  
20  
Max  
ns  
ns  
ns  
ns  
fCP = 16 MHz  
Cycle time  
tCYC  
fCP = 24 MHz  
fCP = 16 MHz  
fCP = 24 MHz  
CLK ↑ → CLK ↓  
tCHCL  
13  
tCYC  
tCHCL  
2.4 V  
2.4 V  
CLK  
0.8 V  
59  
MB90340E Series  
(5) Bus Timing (Read)  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, VSS = 0.0 V, fCP 24 MHz)  
Value  
Sym-  
Parameter  
bol  
Pin  
Condition  
Unit Remarks  
Min  
Max  
ALE pulse width  
tLHLL  
ALE  
tCP/2 10  
ns  
ns  
ns  
ns  
ALE, A23 to A16,  
AD15 to AD00  
Valid address ALE time tAVLL  
tCP/2 20  
tCP/2 15  
tCP 15  
ALE ↓ → Address valid time tLLAX ALE, AD15 to AD00  
A23 to A16,  
Valid address RD time tAVRL  
AD15 to AD00, RD  
Valid address Valid data  
A23 to A16,  
AD15 to AD00  
tAVDV  
5 tCP/2 60 ns  
ns  
3 tCP/2 50 ns  
input  
RD pulse width  
tRLRH  
RD  
3 tCP/2 20  
RD ↓ → Valid data input  
RD ↑ → Data hold time  
RD ↓ → ALE time  
tRLDV RD, AD15 to AD00  
tRHDX RD, AD15 to AD00  
0
ns  
ns  
ns  
tRHLH  
RD, ALE  
tCP/2 15  
tCP/2 10  
RD ↑ → Address valid time tRHAX  
RD, A23 to A16  
A23 to A16,  
AD15 to AD00, CLK  
Valid address CLK time tAVCH  
tCP/2 16  
ns  
RD ↓ → CLK time  
ALE ↓ → RD time  
tRLCH  
tLLRL  
RD, CLK  
ALE, RD  
tCP/2 15  
tCP/2 15  
ns  
ns  
tRLCH  
tAVCH  
2.4 V  
2.4 V  
CLK  
ALE  
RD  
tLLAX  
tAVLL  
tLHLL  
tRHLH  
2.4 V  
2.4 V  
0.8 V  
2.4 V  
tAVRL  
tRLRH  
2.4 V  
0.8 V  
tLLRL  
tRHAX  
2.4 V  
0.8 V  
2.4 V  
0.8 V  
A23 to A16  
tRLDV  
tRHDX  
tAVDV  
2.4 V  
0.8 V  
VIH  
VIL  
2.4 V  
0.8 V  
VIH  
VIL  
AD15 to AD00  
Address  
Read data  
60  
MB90340E Series  
(6) Bus Timing (Write)  
Parameter  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, VSS = 0.0 V, fCP 24 MHz)  
Value  
Symbol  
Pin  
Condition  
Unit Remarks  
Min  
Max  
A23 to A16,  
AD15 to AD00,  
WR  
Valid address WR time  
tAVWL  
tCP15  
ns  
WR pulse width  
tWLWH  
tDVWH  
WR  
3 tCP/2 20  
3 tCP/2 20  
ns  
ns  
Valid data output WR ↑  
time  
AD15 to AD00,  
WR  
AD15 to AD00,  
WR  
WR ↑ → Data hold time  
tWHDX  
tWHAX  
15  
ns  
ns  
A23 to A16,  
WR  
WR ↑ → Address valid time  
tCP/2 10  
WR ↑ → ALE time  
WR ↓ → CLK time  
tWHLH  
tWLCH  
WR, ALE  
WR, CLK  
tCP/2 15  
tCP/2 15  
ns  
ns  
tWLCH  
2.4 V  
CLK  
tWHLH  
2.4 V  
ALE  
tAVWL  
tWLWH  
2.4 V  
WR (WRL, WRH)  
0.8 V  
tWHAX  
2.4 V  
0.8 V  
2.4 V  
0.8 V  
A23 to A16  
tDVWH  
tWHDX  
2.4 V  
0.8 V  
2.4 V  
0.8 V  
2.4 V  
0.8 V  
AD15 to AD00  
Address  
Write data  
61  
MB90340E Series  
(7) Ready Input Timing  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, VSS = 0.0 V, fCP 24 MHz)  
Rated Value  
Test  
Sym-  
Parameter  
bol  
Pin  
Units  
Remarks  
Condition  
Min  
45  
32  
0
Max  
ns fCP = 16 MHz  
ns fCP = 24 MHz  
ns  
RDY setup time  
RDY hold time  
tRYHS  
tRYHH  
RDY  
RDY  
Note : If the RDY setup time is insufficient, use the auto-ready function.  
2.4 V  
CLK  
ALE  
RD/WR  
tRYHS  
tRYHH  
VIH  
VIH  
RDY  
When WAIT is not used.  
RDY  
VIL  
When WAIT is used.  
62  
MB90340E Series  
(8) Hold Timing  
Parameter  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, VSS = 0.0 V, fCP 24 MHz)  
Value  
Symbol  
Pin  
Condition  
Units  
Remarks  
Min  
Max  
Pin floating HAK ↓  
tXHAL  
tHAHV  
HAK  
HAK  
30  
tCP  
ns  
ns  
time  
HAK time Pin valid  
time  
tCP  
2 tCP  
Note : There is more than 1 cycle from when HRQ reads in until the HAK is changed.  
2.4 V  
HAK  
0.8 V  
tHAHV  
tXHAL  
Hi-Z  
2.4 V  
0.8 V  
2.4 V  
0.8 V  
Each pin  
63  
MB90340E Series  
(9) UART0/1/2/3/4  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, VSS = 0.0 V, fCP 24 MHz)  
Value  
Parameter  
Symbol  
Pin  
Condition  
Unit Remarks  
Min  
Max  
Serial clock cycle time  
tSCYC  
SCK0 to SCK4  
8 tCP  
ns  
ns  
SCK0 to SCK4,  
SOT0 to SOT4  
SCK ↓ → SOT delay time  
tSLOV  
80  
100  
60  
+80  
Internal clock  
operation output  
pins are  
SCK0 to SCK4,  
SIN0 to SIN4  
Valid SIN SCK ↑  
tIVSH  
tSHIX  
ns  
ns  
CL = 80 pF + 1 TTL  
SCK0 to SCK4,  
SIN0 to SIN4  
SCK ↑ → Valid SIN hold time  
Serial clock “H” pulse width  
Serial clock “L” pulse width  
tSHSL  
SCK0 to SCK4  
SCK0 to SCK4  
4 tCP  
ns  
ns  
tSLSH  
4 tCP  
SCK0 to SCK4, External clock  
SOT0 to SOT4 operation output  
SCK ↓ → SOT delay time  
Valid SIN SCK ↑  
tSLOV  
tIVSH  
tSHIX  
60  
60  
150  
ns  
ns  
ns  
pins are  
CL = 80 pF + 1 TTL  
SCK0 to SCK4,  
SIN0 to SIN4  
SCK0 to SCK4,  
SIN0 to SIN4  
SCK ↑ → Valid SIN hold time  
Notes : AC characteristic CLK synchronized mode.  
CL is the value of the load capacitance applied to the pins during testing.  
Internal Shift Clock Mode  
tSCYC  
2.4 V  
SCK  
SOT  
0.8 V  
0.8 V  
tSLOV  
2.4 V  
0.8 V  
tIVSH  
tSHIX  
VIH  
VIL  
VIH  
VIL  
SIN  
64  
MB90340E Series  
External Shift Clock Mode  
tSLSH  
tSHSL  
VIH  
VIH  
SCK  
VIL  
tSLOV  
VIL  
2.4 V  
0.8 V  
SOT  
SIN  
tIVSH  
tSHIX  
VIH  
VIL  
VIH  
VIL  
(10) Trigger Input Timing  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, fCP 24 MHz, VSS = 0.0 V)  
Value  
Parameter  
Symbol  
Pin  
Condition  
Unit  
Remarks  
Min  
Max  
INT0 to INT15,  
INT0R to INT15R,  
ADTG  
tTRGH  
tTRGL  
Input pulse width  
5 tCP  
ns  
VIH  
VIH  
INT0 to INT15,  
VIL  
VIL  
INT0R to INT15R,  
ADTG  
tTRGH  
tTRGL  
65  
MB90340E Series  
(11) Timer Related Resource Input Timing  
(TA = −40 °C to +105 °C, VCC = 5.0 V 10%, fCP 24 MHz, VSS = 0 V)  
Value  
Parameter  
Symbol  
Pin  
Condition  
Unit  
Remarks  
Min  
Max  
tTIWH  
tTIWL  
TIN0 to TIN3,  
IN0 to IN7  
Input pulse width  
4 tCP  
ns  
VIH  
VIH  
VIL  
VIL  
TIN0 to TIN3,  
IN0 to IN7  
tTIWH  
tTIWL  
(12) Timer Related Resource Output Timing  
(TA = –40°C to +105°C, VCC = 5.0 V 10%, fCP 24 MHz, VSS = 0.0 V)  
Value  
Parameter  
Symbol  
Pin  
Condition  
Unit  
Remarks  
Min  
Max  
TOT0 to TOT3,  
PPG0 to PPGF  
CLK ↑ → TOUT change time  
tTO  
30  
ns  
2.4 V  
CLK  
2.4 V  
0.8 V  
TOT0 to TOT3,  
PPG0 to PPGF  
tTO  
66  
MB90340E Series  
(13) I2C Timing  
(TA = –40°C to +105°C, VCC = 5.0 V 10%, VSS = 0.0 V)  
Fast-mode*1  
Standard-mode  
Parameter  
Symbol  
Condition  
Unit  
Min  
Max  
Min  
Max  
SCL clock frequency  
fSCL  
0
100  
0
400  
kHz  
Hold time (repeated) START condition  
SDA↓ → SCL ↓  
tHDSTA  
4.0  
0.6  
µs  
“L” width of the SCL clock  
“H” width of the SCL clock  
tLOW  
4.7  
4.0  
1.3  
0.6  
µs  
µs  
tHIGH  
Set-up time (repeated) START condition  
SCL ↑ → SDA ↓  
tSUSTA  
tHDDAT  
tSUDAT  
tSUSTO  
tBUS  
4.7  
0
3.45*3  
0.6  
0
0.9*4  
µs  
µs  
ns  
µs  
µs  
R = 1.7 k,  
C = 50 pF*2  
Data hold time  
SCL ↓ → SDA ↓ ↑  
Data set-up time  
SDA ↓ ↑ → SCL ↑  
250  
4.0  
4.7  
100  
0.6  
1.3  
Set-up time for STOP condition  
SCL ↑ → SDA ↑  
Bus free time between a STOP and START  
condition  
*1: For use at over 100 kHz, set the machine clock to at least 6 MHz.  
*2: R,C: Pull-up resistor and load capacitor of the SCL and SDA lines.  
*3: The maximum tHDDAT meets the requirement that it does not extend the “L” width (tLOW) of the SCL signal.  
*4: A Fast-mode I2C-bus device can be used in a Standard-mode I2C-bus system, but the requirement  
tSUDAT 250 ns must then be met.  
SDA  
tBUS  
tSUDAT  
tHDSTA  
tLOW  
SCL  
tHIGH  
tHDSTA  
tHDDAT  
tSUSTA  
tSUSTO  
67  
MB90340E Series  
5. A/D Converter  
(TA  
= −40 °C to +105 °C, 3.0 V AVRH AVRL, VCC = AVCC = 5.0 V 10%, fCP 24 MHz, VSS = AVSS = 0 V)  
Value  
Parameter  
Symbol  
Pin  
Unit  
Remarks  
Min  
Typ  
Max  
10  
Resolution  
bit  
Total error  
3.0  
2.5  
LSB  
LSB  
Nonlinearity error  
Differential  
nonlinearity error  
1.9  
LSB  
Zero reading  
voltage  
VOT  
VFST  
AN0 to AN23 AVRL 1.5 AVRL + 0.5 AVRL + 2.5 LSB  
Full scale reading  
voltage  
AN0 to AN23 AVRH 3.5 AVRH 1.5 AVRH + 0.5 LSB  
1.0  
4.5 V AVCC 5.5 V  
4.0 V AVCC < 4.5 V  
4.5 V AVCC 5.5 V  
4.0 V AVCC < 4.5 V  
Compare time  
Sampling time  
16500  
µs  
µs  
2.0  
0.5  
1.2  
Analog port input  
current  
IAIN  
AN0 to AN23  
AN0 to AN23  
0.3  
+0.3  
µA  
Analog input  
voltage range  
VAIN  
AVRL  
AVRH  
V
IA  
AVRH  
AVRL  
AVCC  
AVRL + 2.7  
AVCC  
V
V
Reference  
voltage range  
0
AVRH 2.7  
3.5  
7.5  
5
mA  
µA  
µA  
µA  
Power supply  
current  
IAH  
IR  
AVCC  
*
*
AVRH  
AVRH  
600  
900  
5
Reference  
voltage current  
IRH  
Offset between  
input channels  
AN0 to AN23  
4
LSB  
*: If the A/D convertor is not operating, a current when CPU is stopped is applicable (VCC = AVCC = AVRH = 5.0 V) .  
Note: The accuracy gets worse as |AVRH AVRL| becomes smaller.  
68  
MB90340E Series  
6. Definition of A/D Converter Terms  
Resolution  
: Analog variation that is recognized by the A/D converter.  
Non linearity  
error  
: The deviation between the actual conversion characteristics and a line that joins the  
zero-transition line ( “00 0000 0000” ← → “00 0000 0001” ) to the full-scale transition line  
( “11 1111 1110” ← → “11 1111 1111” ) .  
Differential  
linearity error  
: Deviation of input voltage, which is required for changing output code by 1 LSB, from an  
ideal value.  
Total error  
: Difference between the actual value and the ideal value. The total error includes zero  
transition error, full-scale transition error, and linear error.  
Total error  
3FFH  
1.5 LSB  
3FEH  
3FDH  
Actual conversion  
characteristics  
{1 LSB × (N 1) + 0.5 LSB}  
004H  
003H  
002H  
001H  
VNT  
(Actually-measured value)  
Actual conversion  
characteristics  
Ideal characteristics  
0.5 LSB  
AVRL  
AVRH  
Analog input  
VNT {1 LSB × (N 1) + 0.5 LSB}  
[LSB]  
Total error of digital output “N” =  
1 LSB (Ideal value) =  
1 LSB  
AVRH AVRL  
[V]  
1024  
N : Value of the digital output from the A/D converter  
VOT (Ideal value) = AVRL + 0.5 LSB [V]  
VFST (Ideal value) = AVRH 1.5 LSB [V]  
VNT : A voltage at which the digital output transitions from (N 1) to N.  
(Continued)  
69  
MB90340E Series  
(Continued)  
Non linearity error  
Differential linearity error  
Ideal  
characteristics  
3FFH  
Actual conversion  
characteristics  
3FEH  
N + 1H  
Actual conversion  
characteristics  
{1 LSB × (N 1)  
+ VOT }  
3FDH  
VFST (actual  
measurement  
value)  
NH  
VNT (actual  
measurement value)  
004H  
003H  
002H  
001H  
V (N + 1) T  
(actual measurement  
value)  
Actual conversion  
characteristics  
N 1H  
N 2H  
VNT  
(actual measurement value)  
Ideal characteristics  
Actual conversion  
characteristics  
VOT (actual measurement value)  
Analog input  
AVRL  
AVRH  
AVRL  
AVRH  
Analog input  
VNT {1 LSB × (N 1) + VOT}  
[LSB]  
Non linearity error of digital output N =  
1 LSB  
V (N+1) T VNT  
1 LSB [LSB]  
1 LSB  
Differential linearity error of digital output N =  
1 LSB =  
VFST VOT  
[V]  
1022  
N
: Value of the digital output from the A/D converter  
VOT : Voltage at which digital output transits from “000H” to “001H.”  
VFST : Voltage at which digital output transits from “3FEH” to “3FFH.”  
70  
MB90340E Series  
7. Notes on A/D Converter Section  
Use the device with external circuits of the following output impedance for analog inputs :  
Recommended output impedance of external circuits are : Approx. 1.5 kor lower (4.0 V AVCC 5.5 V,  
sampling period = 0.5 µs)  
If an external capacitor is used, in consideration of the capacitive voltage dividing effect between the external  
capacitor and the internal on-chip capacitor, it is recommended that the capacitance of the external capacitor  
be several thousand times greater than the capacitance of the internal capacitor.  
If the output impedance of the external circuit is too high, a sampling period for an analog voltage may be  
insufficient.  
• Analog input circuit model  
R
Analog input  
Comparator  
C
4.5 V AVCC 5.5 V : R=: 2.52 k, C=: 10.7 pF  
4.0 V AVCC < 4.5 V : R=: 13.6 k, C=: 10.7 pF  
Note : Use the values in the figure only as a guideline.  
8. Flash Memory Program/Erase Characteristics  
Value  
Parameter  
Conditions  
Unit  
Remarks  
Min  
Typ  
Max  
Excludes programming  
prior to erasure  
Sector erase time  
Chip erase time  
1
9
15  
s
s
TA = +25 °C  
VCC = 5.0 V  
Excludes programming  
prior to erasure  
Word (16-bit width)  
programming time  
Except for the over head  
time of the system  
10000  
20  
16  
3600  
µs  
Program/Erase cycle  
cycle  
year  
Flash Data Retention  
Time  
Average  
TA = +85 °C  
*
* : This value was converted from the results of evaluating the reliability of the technology (using Arrhenius equation  
to translate high temperature measurements into normalized value at +85 °C) .  
71  
MB90340E Series  
EXAMPLE CHARACTERISTICS  
• MB90F346E, MB90F346ES, MB90F346CE, MB90F346CES  
ICC VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCL VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
100  
70  
60  
50  
40  
30  
20  
10  
0
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
f = 24 MHz  
f = 20 MHz  
f = 16 MHz  
f = 8 kHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 4 MHz  
f = 2 MHz  
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
ICCS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCLS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
35  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
30  
25  
20  
15  
10  
5
f = 24 MHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 8 kHz  
f = 4 MHz  
f = 2 MHz  
0
0
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
ICTS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCT VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
400  
350  
300  
250  
200  
150  
100  
50  
20  
18  
16  
14  
12  
10  
8
6
4
2
0
f = 2 MHz  
f = 8 kHz  
0
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
ICTSPLL6 VCC  
ICCH VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, stopped  
10  
9
8
7
6
5
4
3
2
1
0
10  
9
8
7
6
5
4
3
2
1
0
f = 24 MHz  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
72  
MB90340E Series  
• MB90F347E, MB90F347ES, MB90F347CE, MB90F347CES  
ICC VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCL VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
100  
70  
60  
50  
40  
30  
20  
10  
0
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
f = 24 MHz  
f = 20 MHz  
f = 16 MHz  
f = 8 kHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 4 MHz  
f = 2 MHz  
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
ICCS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCLS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
35  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
30  
25  
20  
15  
10  
5
f = 24 MHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 8 kHz  
f = 4 MHz  
f = 2 MHz  
0
0
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
ICTS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCT VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
400  
350  
300  
250  
200  
150  
100  
50  
20  
18  
16  
14  
12  
10  
8
6
4
2
0
f = 2 MHz  
f = 8 kHz  
0
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
ICTSPLL6 VCC  
ICCH VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, stopped  
10  
9
8
7
6
5
4
3
2
1
0
10  
9
8
7
6
5
4
3
2
1
0
f = 24 MHz  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
73  
MB90340E Series  
• MB90F349E, MB90F349ES, MB90F349CE, MB90F349CES  
ICC VCC  
ICCL VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
f = 24 MHz  
f = 8 kHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 4 MHz  
f = 2 MHz  
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
ICCS VCC  
ICCLS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
35  
30  
25  
20  
15  
10  
5
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
f = 24 MHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 8 kHz  
f = 4 MHz  
f = 2 MHz  
0
0
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
ICTS VCC  
ICCT VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
400  
350  
300  
250  
200  
150  
100  
50  
20  
18  
16  
14  
12  
10  
8
6
4
2
f = 2 MHz  
f = 8 kHz  
0
0
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
ICTSPLL6 VCC  
ICCH VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, stopped  
10  
9
8
7
6
5
4
3
2
1
0
10  
9
8
7
6
5
4
3
2
1
0
f = 24 MHz  
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
74  
MB90340E Series  
• MB90F342E, MB90F342ES, MB90F342CE, MB90F342CES  
ICC VCC  
ICCL VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
f = 24 MHz  
f = 8 kHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 4 MHz  
f = 2 MHz  
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
ICCS VCC  
ICCLS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
35  
30  
25  
20  
15  
10  
5
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
f = 24 MHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 8 kHz  
f = 4 MHz  
f = 2 MHz  
0
0
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
ICTS VCC  
ICCT VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
400  
350  
300  
250  
200  
150  
100  
50  
20  
18  
16  
14  
12  
10  
8
6
4
2
f = 2 MHz  
f = 8 kHz  
0
0
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
ICTSPLL6 VCC  
ICCH VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, stopped  
10  
9
8
7
6
5
4
3
2
1
0
10  
9
8
7
6
5
4
3
2
1
0
f = 24 MHz  
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
75  
MB90340E Series  
• MB90F345E, MB90F345ES, MB90F345CE, MB90F345CES  
ICC VCC  
ICCL VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
70  
60  
50  
40  
30  
20  
10  
0
f = 24 MHz  
f = 8 kHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 4 MHz  
f = 2 MHz  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
ICCS VCC  
ICCLS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
50  
45  
40  
35  
30  
25  
20  
15  
10  
5
35  
30  
25  
20  
15  
10  
5
f = 24 MHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 8 kHz  
f = 4 MHz  
f = 2 MHz  
0
0
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
ICTS VCC  
ICCT VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
400  
350  
300  
250  
200  
150  
100  
50  
20  
18  
16  
14  
12  
10  
8
6
4
2
f = 2 MHz  
f = 8 kHz  
0
0
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
ICTSPLL6 VCC  
ICCH VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, stopped  
10  
9
8
7
6
5
4
3
2
1
0
10  
9
8
7
6
5
4
3
2
1
0
f = 24 MHz  
2.5  
3.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
76  
MB90340E Series  
• MB90346E, MB90346ES, MB90346CE, MB90346CES  
ICC VCC  
ICCL VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
70  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
60  
f = 24 MHz  
50  
f = 20 MHz  
f = 16 MHz  
40  
30  
20  
10  
0
f = 8 kHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 4 MHz  
f = 2 MHz  
2.5  
2.5  
2.5  
3.5  
3.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
3.5  
3.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
ICCS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCLS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
50  
35  
30  
25  
20  
15  
10  
5
45  
40  
35  
30  
25  
20  
15  
10  
5
f = 24 MHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 8 kHz  
f = 4 MHz  
f = 2 MHz  
0
0
2.5  
4.5  
VCC (V)  
5.5  
6.5  
4.5  
5.5  
6.5  
VCC (V)  
ICTS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCT VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
20  
18  
16  
14  
12  
10  
8
6
4
2
0
400  
350  
300  
250  
200  
150  
100  
50  
f = 2 MHz  
f = 8 kHz  
0
2.5  
4.5  
VCC (V)  
5.5  
6.5  
4.5  
VCC (V)  
5.5  
6.5  
ICTSPLL6 VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCH VCC  
TA = +25 °C, stopped  
10  
9
8
7
6
5
4
3
2
1
0
10  
9
8
7
6
5
4
3
2
1
0
f = 24 MHz  
2.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
77  
MB90340E Series  
• MB90347E, MB90347ES, MB90347CE, MB90347CES  
ICC VCC  
ICCL VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
70  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
60  
f = 24 MHz  
50  
f = 20 MHz  
f = 16 MHz  
40  
30  
20  
10  
0
f = 8 kHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 4 MHz  
f = 2 MHz  
2.5  
2.5  
2.5  
3.5  
3.5  
3.5  
4.5  
VCC (V)  
5.5  
6.5  
2.5  
3.5  
3.5  
3.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
ICCS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCLS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
50  
35  
30  
25  
20  
15  
10  
5
45  
40  
35  
30  
25  
20  
15  
10  
5
f = 24 MHz  
f = 20 MHz  
f = 16 MHz  
f = 12 MHz  
f = 10 MHz  
f = 8 MHz  
f = 8 kHz  
f = 4 MHz  
f = 2 MHz  
0
0
2.5  
4.5  
VCC (V)  
5.5  
6.5  
4.5  
5.5  
6.5  
VCC (V)  
ICTS VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCT VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
20  
18  
16  
14  
12  
10  
8
6
4
2
0
400  
350  
300  
250  
200  
150  
100  
50  
f = 2 MHz  
f = 8 kHz  
0
2.5  
4.5  
VCC (V)  
5.5  
6.5  
4.5  
VCC (V)  
5.5  
6.5  
ICTSPLL6 VCC  
TA = +25 °C, external clock operation  
f = Internal operation frequency  
ICCH VCC  
TA = +25 °C, stopped  
10  
9
8
7
6
5
4
3
2
1
0
10  
9
8
7
6
5
4
3
2
1
0
f = 24 MHz  
2.5  
4.5  
5.5  
6.5  
2.5  
3.5  
4.5  
5.5  
6.5  
VCC (V)  
VCC (V)  
78  
MB90340E Series  
• I/O characteristics  
(VCCVOH) IOH  
VOL IOL  
TA = +25 °C, VCC = 4.5 V  
TA = +25 °C, VCC = 4.5 V  
800  
700  
600  
500  
400  
300  
200  
100  
0
1000  
900  
800  
700  
600  
500  
400  
300  
200  
100  
0
0
1
2
3
4
5
6
7
8
9
10  
0
1
2
3
4
5
6
7
8
9
10  
IOL (mA)  
IOH (mA)  
Automotive VIN VCC  
CMOS VIN VCC  
Other than UART-SIN pin and I2C pin  
TA = +25 °C  
TA = +25 °C  
5.0  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
5.0  
4.5  
VIHA  
VILA  
VIHS  
VILS  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0  
VCC (V)  
2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0  
VCC (V)  
TTL VIN VCC  
CMOS VIN VCC  
UART-SIN pin, I2C pin  
TA = +25 °C  
TA = +25 °C  
5.0  
4.5  
4.0  
3.5  
3.0  
2.5  
2.0  
1.5  
1.0  
0.5  
0.0  
2.5  
2.3  
2.0  
1.8  
1.5  
1.3  
1.0  
0.8  
0.5  
0.3  
0.0  
VIHS  
VILS  
VIHT  
VILT  
2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0  
VCC (V)  
2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0  
VCC (V)  
79  
MB90340E Series  
ORDERING INFORMATION  
Part number  
MB90F342EPF  
Package  
Remarks  
MB90F342ESPF  
MB90F342CEPF  
MB90F342CESPF  
MB90F342EPFV  
MB90F342ESPFV  
MB90F342CEPFV  
MB90F342CESPFV  
MB90F343EPF  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
MB90F343ESPF  
MB90F343CEPF  
MB90F343CESPF  
MB90F343EPFV  
MB90F343ESPFV  
MB90F343CEPFV  
MB90F343CESPFV  
MB90F345EPF  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
MB90F345ESPF  
MB90F345CEPF  
MB90F345CESPF  
MB90F345EPFV  
MB90F345ESPFV  
MB90F345CEPFV  
MB90F345CESPFV  
MB90F346EPF  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
MB90F346ESPF  
MB90F346CEPF  
MB90F346CESPF  
MB90F346EPFV  
MB90F346ESPFV  
MB90F346CEPFV  
MB90F346CESPFV  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
(Continued)  
80  
MB90340E Series  
Part number  
MB90F347EPF  
Package  
Remarks  
MB90F347ESPF  
MB90F347CEPF  
MB90F347CESPF  
MB90F347EPFV  
MB90F347ESPFV  
MB90F347CEPFV  
MB90F347CESPFV  
MB90F349EPF  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
MB90F349ESPF  
MB90F349CEPF  
MB90F349CESPF  
MB90F349EPFV  
MB90F349ESPFV  
MB90F349CEPFV  
MB90F349CESPFV  
MB90341EPF  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
MB90341ESPF  
100-pin plastic QFP  
(FPT-100P-M06)  
MB90341CEPF  
MB90341CESPF  
MB90341EPFV  
MB90341ESPFV  
MB90341CEPFV  
MB90341CESPFV  
MB90342EPF  
100-pin plastic LQFP  
(FPT-100P-M05)  
MB90342ESPF  
100-pin plastic QFP  
(FPT-100P-M06)  
MB90342CEPF  
MB90342CESPF  
MB90342EPFV  
MB90342ESPFV  
MB90342CEPFV  
MB90342CESPFV  
100-pin plastic LQFP  
(FPT-100P-M05)  
(Continued)  
81  
MB90340E Series  
(Continued)  
Part number  
Package  
Remarks  
MB90346EPF  
MB90346ESPF  
MB90346CEPF  
MB90346CESPF  
MB90346EPFV  
MB90346ESPFV  
MB90346CEPFV  
MB90346CESPFV  
MB90347EPF  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
MB90347ESPF  
MB90347CEPF  
MB90347CESPF  
MB90347EPFV  
MB90347ESPFV  
MB90347CEPFV  
MB90347CESPFV  
MB90348EPF  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
MB90348ESPF  
MB90348CEPF  
MB90348CESPF  
MB90348EPFV  
MB90348ESPFV  
MB90348CEPFV  
MB90348CESPFV  
MB90349EPF  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
MB90349ESPF  
MB90349CEPF  
MB90349CESPF  
MB90349EPFV  
MB90349ESPFV  
MB90349CEPFV  
MB90349CESPFV  
MB90V340E-101  
MB90V340E-102  
100-pin plastic QFP  
(FPT-100P-M06)  
100-pin plastic LQFP  
(FPT-100P-M05)  
299-pin Ceramic PGA  
(PGA-299C-A01)  
For evaluation  
82  
MB90340E Series  
PACKAGE DIMENSIONS  
100-pin plastic QFP  
Lead pitch  
0.65 mm  
14.00 × 20.00 mm  
Gullwing  
Package width ×  
package length  
Lead shape  
Sealing method  
Mounting height  
Plastic mold  
3.35 mm MAX  
P-QFP100-14×20-0.65  
Code  
(Reference)  
(FPT-100P-M06)  
100-pin plastic QFP  
(FPT-100P-M06)  
Note 1) * : These dimensions do not include resin protrusion.  
Note 2) Pins width and pins thickness include plating thickness.  
Note 3) Pins width do not include tie bar cutting remainder.  
23.90 0.40(.941 .016)  
*
20.00 0.20(.787 .008)  
80  
51  
81  
50  
0.10(.004)  
17.90 0.40  
(.705 .016)  
*
14.00 0.20  
(.551 .008)  
INDEX  
Details of "A" part  
100  
31  
0.25(.010)  
3.00 +00..2305  
.118 +..000184  
(Mounting height)  
0~8˚  
1
30  
0.65(.026)  
0.32 0.05  
(.013 .002)  
0.17 0.06  
(.007 .002)  
M
0.13(.005)  
0.25 0.20  
(.010 .008)  
(Stand off)  
0.80 0.20  
(.031 .008)  
"A"  
0.88 0.15  
(.035 .006)  
Dimensions in mm (inches).  
Note: The values in parentheses are reference values.  
C
2002 FUJITSU LIMITED F100008S-c-5-5  
Please confirm the latest Package dimension by following URL.  
http://edevice.fujitsu.com/fj/DATASHEET/ef-ovpklv.html  
(Continued)  
83  
MB90340E Series  
(Continued)  
100-pin plastic LQFP  
Lead pitch  
0.50 mm  
14.0 × 14.0 mm  
Gullwing  
Package width ×  
package length  
Lead shape  
Sealing method  
Mounting height  
Weight  
Plastic mold  
1.70 mm MAX  
0.65g  
Code  
(Reference)  
(FPT-100P-M05)  
P-LFQFP100-14×14-0.50  
100-pin plastic LQFP  
(FPT-100P-M05)  
Note 1) * : These dimensions do not include resin protrusion.  
Note 2) Pins width and pins thickness include plating thickness.  
Note 3) Pins width do not include tie bar cutting remainder.  
16.00 0.20(.630 .008)SQ  
*
14.00 0.10(.551 .004)SQ  
75  
51  
76  
50  
0.08(.003)  
Details of "A" part  
1.50 +00..1200 .059 +..000048  
(Mounting height)  
INDEX  
0.10 0.10  
(.004 .004)  
(Stand off)  
100  
26  
0˚~8˚  
"A"  
0.50 0.20  
(.020 .008)  
0.25(.010)  
1
25  
0.60 0.15  
(.024 .006)  
0.50(.020)  
0.20 0.05  
(.008 .002)  
0.145 0.055  
(.0057 .0022)  
M
0.08(.003)  
Dimensions in mm (inches).  
Note: The values in parentheses are reference values.  
C
2003 FUJITSU LIMITED F100007S-c-4-6  
Please confirm the latest Package dimension by following URL.  
http://edevice.fujitsu.com/fj/DATASHEET/ef-ovpklv.html  
84  
MB90340E Series  
The information for microcontroller supports is shown in the following homepage.  
http://www.fujitsu.com/global/services/microelectronics/product/micom/support/index.html  
FUJITSU LIMITED  
All Rights Reserved.  
The contents of this document are subject to change without notice.  
Customers are advised to consult with FUJITSU sales  
representatives before ordering.  
The information, such as descriptions of function and application  
circuit examples, in this document are presented solely for the  
purpose of reference to show examples of operations and uses of  
Fujitsu semiconductor device; Fujitsu does not warrant proper  
operation of the device with respect to use based on such  
information. When you develop equipment incorporating the  
device based on such information, you must assume any  
responsibility arising out of such use of the information. Fujitsu  
assumes no liability for any damages whatsoever arising out of  
the use of the information.  
Any information in this document, including descriptions of  
function and schematic diagrams, shall not be construed as license  
of the use or exercise of any intellectual property right, such as  
patent right or copyright, or any other right of Fujitsu or any third  
party or does Fujitsu warrant non-infringement of any third-party’s  
intellectual property right or other right by using such information.  
Fujitsu assumes no liability for any infringement of the intellectual  
property rights or other rights of third parties which would result  
from the use of information contained herein.  
The products described in this document are designed, developed  
and manufactured as contemplated for general use, including  
without limitation, ordinary industrial use, general office use,  
personal use, and household use, but are not designed, developed  
and manufactured as contemplated (1) for use accompanying fatal  
risks or dangers that, unless extremely high safety is secured, could  
have a serious effect to the public, and could lead directly to death,  
personal injury, severe physical damage or other loss (i.e., nuclear  
reaction control in nuclear facility, aircraft flight control, air traffic  
control, mass transport control, medical life support system, missile  
launch control in weapon system), or (2) for use requiring  
extremely high reliability (i.e., submersible repeater and artificial  
satellite).  
Please note that Fujitsu will not be liable against you and/or any  
third party for any claims or damages arising in connection with  
above-mentioned uses of the products.  
Any semiconductor devices have an inherent chance of failure. You  
must protect against injury, damage or loss from such failures by  
incorporating safety design measures into your facility and  
equipment such as redundancy, fire protection, and prevention of  
over-current levels and other abnormal operating conditions.  
If any products described in this document represent goods or  
technologies subject to certain restrictions on export under the  
Foreign Exchange and Foreign Trade Law of Japan, the prior  
authorization by Japanese government will be required for export  
of those products from Japan.  
Edited  
Business Promotion Dept.  
F0611  

相关型号:

MB90F347ESPF

16-bit Proprietary Microcontroller CMOS
FUJITSU

MB90F347ESPFV

16-bit Proprietary Microcontroller CMOS
FUJITSU

MB90F347ESPMC

Microcontroller, 16-Bit, FLASH, 24MHz, CMOS, PQFP100, 14 X 14 MM, 1.70 MM HEIGHT, 0.50 MM PITCH, PLASTIC, LQFP-100
FUJITSU

MB90F347PF

Microcontroller, 16-Bit, FLASH, 24MHz, CMOS, PQFP100, PLASTIC, QFP-100
CYPRESS

MB90F347PFV

Microcontroller, 16-Bit, FLASH, 24MHz, CMOS, PQFP100, PLASTIC, LQFP-100
CYPRESS

MB90F347SPF

Microcontroller, 16-Bit, FLASH, 24MHz, CMOS, PQFP100, PLASTIC, QFP-100
CYPRESS

MB90F347SPFV

Microcontroller, 16-Bit, FLASH, 24MHz, CMOS, PQFP100, PLASTIC, LQFP-100
CYPRESS

MB90F349CAPFV

暂无描述
FUJITSU

MB90F349CE

16-bit Proprietary Microcontroller CMOS
FUJITSU

MB90F349CEPF

16-bit Proprietary Microcontroller CMOS
FUJITSU

MB90F349CEPFV

16-bit Proprietary Microcontroller CMOS
FUJITSU

MB90F349CEPMC

Microcontroller, 16-Bit, FLASH, 24MHz, CMOS, PQFP100, 14 X 14 MM, 1.70 MM HEIGHT, 0.50 MM PITCH, PLASTIC, LQFP-100
FUJITSU