EDS5-89 [FUJI]
OPTICAL PRESSURE TRANSMITTER REMOTE SEAL TYPE; 光压力变送器远传密封式型号: | EDS5-89 |
厂家: | FUJI ELECTRIC |
描述: | OPTICAL PRESSURE TRANSMITTER REMOTE SEAL TYPE |
文件: | 总8页 (文件大小:130K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FFI SYSTEM
OPTICAL PRESSURE TRANSMITTER REMOTE SEAL TYPE
DATA SHEET
FBM…3
The Model FBM 3 Optical Pressure Transmitter Remote
Seal Type measures pressures of various fluids accurately,
converts them into optical digital signals and outputs them.
This is an intelligent transmitter providing excellent perfor-
mance and functions due to incorporation of electrostatic
capacitance type silicon sensor and microprocessor.
A fiber optic cable used for the signal transmission line
forms an optical field instrumentation system together with
an optical star coupler and a master station.
FEATURES
1. Resistive to noise and lightning
Optical signal ensures a reliable signal transmission, be-
cause it is not affected by external noise and inductive
lightning. Use of a nonmetallic optical (fiber) cable pre-
vents propagation of inductive lightning through the cable,
so a signal transmission immune to lightning can be real-
ized.
2. Reliability due to redundant configuration
Host system can be duplicated by using two optical cable
trunk lines (between an optical star coupler and host sys-
tem). This enhances reliability of users’ systems.
3. Intrinsic safety type explosion-proof
Process temperature, Allowable pressure limit:
13th
code
digit
Process
temperature pressure limit
Allowable
Fill-fluid
Fluorolube oil
Silicon oil
Silicon oil
Silicon oil
Silicon oil
Silicon oil
W, A, D
-
-
20 to 120˚C Atmospheric pressure
or higher
H
15 to 250˚C
J
ꢀ85 to 300˚C
Y, G
S
-
-
40 to 120˚C 2.7 kPa abs or higher
See Fig. 1.
15 to 250˚C
T
ꢀ85 to 300˚C
0.13 kPa abs or higher
See Fig. 2.
Silicon oil
K
-15 to 200˚C
Each equipment with a built-in battery can be constructed
so as to be an intrinsic safety type individually (intrinsic
safety type barrier unnecessary).
For small bores 40A, 50A, 1-1/2B, 2B:
13th
code
digit
Process
temperature pressure limit
Allowable
Fill-fluid
-
-
20 to 120˚C
0 to 250˚C
40 to 120˚C
0 to 250˚C
W, A, D
Fluorolube oil
Silicon oil
Atmospheric pressure
or higher
SPECIFICATIONS
H
Y, G
S
Silicon oil
2.7 kPa abs or higher
See Fig. 1.
Functional specifications
Silicon oil
Fluids measured: Liquid, gas or steam
Measuring range:
Self-diagnosis: Displayed on indication unit (option) and
transmitted to master station.
Max.
allowable
over-
pressure
[MPa]
Span [kPa]
Range limit [kPa]
Item
Host system Indication unit
Type
Lower
range
limit
Maxi-
mum
value
Upper
range
limit
Mini-
mum
value
Measuring range abnormal
Detecting unit failure
Amplifier abnormal
Battery voltage
○
○
○
○
○
○
○
○
-
○
FBM□□1 3.25
FBM□□2 12.5
130
500
130
500
1
1.5
4.5
15
75
Battery voltage low alarm
FBM□□3
FBM□□4
75
3000
10000
50000
3000
10000
50000
Remote control function:
See Table 1.
Output signal: Optical digital signal
250
FBM□□5 1250
Power supply: Built-in lithium battery
(expected life about 4 years)
Optical cable:
Code set type, silica fiber ... core/clad di-
ameter 100/140 µm
Operating pressure:
Up to the maximum value of
measuring range, provided
the maximum operating pressure
of flange should not be exceeded.
Optical connector:
FC connector
EDS5-89
Date May 20, 2004
FBM···3
Transmission distance:
Ambient temperature effect:
1.5 km max. (when transmission loss of
For small bores 40A, 50A, 1-1/2B, 2B:
optical cable is 4 dB/km)
Zero shift: ±0.7% / 28°C (x equal to 1/2
Damping:
Variable from 0.2 to 32 sec (time constant)
URL or more)
URL
2x
Zero elevation and suppression:
Possible within a range from
to maximum span.
Explosion-proof: Intrinsic safety type, JIS ib IIC T3
Ambient temperature:
Zero shift: ±0.7
% / 28°C (x less
-
0.1 MPa
than 1/2 URL)
Overall shift: ±0.9% / 28°C (x equal to
1/2 URL or more)
Overall shift: ±(0.4 + 0.5
URL
)% /
2x
–30 to +70°C
–10 to +60°C for intrinsic safety explo-
sion-proof type
–20 to +70°C when provided with indica-
28°C (x less than 1/2 URL)
Note 1: Condition; Capillary length is
limited to max. 3 m. With a
capillary of 5 m long, the effect
is 1.5 times as large as the
above.
Note 2: The effect is 2.5 times as large
as the above when the 7th
code digit (material) is other
than V, A, B, C and D.
tor
–10 to +60°C when filled with fluorolube
oil
–10 to +70°C for silicone oil codes H, S
and K
+20 to +70°C for silicone oil codes J and
T
Maximum allowable pressure effect:
For small bores 40A, 50A, 1-1/2B, 2B:
Zero shift at maximum span
±0.2% / nominal pressure of flange
For small bores 40A, 50A, 1-1/2B, 2B:
±0.2% / (1.5 x URL)
–15 to +65°C
–10 to +60°C for intrinsic safety explo-
sion-proof type
–15 to +65°C when provided with indica-
URL: Maximum span
tor
Measurement period:
–10 to +60°C when filled with fluorolube
0.2 sec
oil
–10 to +60°C for silicone oil codes H and
S.
Response time: Time constant 0.3 sec (Value at capil-
lary length 1.5 m and 23°C)
Dead time: About 0.2 sec
Storage temperature:
–40 to +80°C
Physical specifications
Performance specifications
Flange material: SUS304
Screw-in design for 10 and 50 MPa
specifications (thread material: carbon
steel)
±0.2% when measuring span is 1/10 or more
Accuracy rating(Note)
of maximum span
max. span
±(0.1 + 0.01
)% when
Material:
measuring span
measuring span is less than 1/10 of maximum
span.
Other wetted parts
SUS316
Hastelloy-C�
Monel�
Tantalum
Titanium�
Zirconium
Seal diaphragm
SUS316L
Hastelloy-C�
Monel�
Tantalum
Titanium�
Zirconium
Material code
V, A, B, C, D
H, F, G, K, L
Note: Percent value with respect to measuring span (including
linearity, hysteresis and repeatability in standard 23°C status)
M
T
P
For small bores 40A, 50A, 1-1/2B, 2B:
±0.25% when measuring span is 1/10 or more
R
Accuracy rating(Note)
of maximum span
Note 1: Selected according to combination of type codes.
Refer to CODE SYMBOLS.
max. span
measuring span
±(0.17 + 0.008
)% when
measuring span is less than 1/10 of maximum
span.
Capillary:
Finish:
Stainless steel pipe coated with PVC
Epoxy-polyurethane double coat,
Color: silver (blue for amplifier case cover)
Ambient temperature effect:
Zero shift: ±(0.5
Environmental protection:
Meets JIS C0920, immersion-proof
(equivalent to IEC IP67 or NEMA 6/6P)
External dimensions:
URL
x
)% / 28°C
URL
Overall shift: ±(0.7
Where; URL: Maximum span
x : Measuring span
2 times as large as above when the 7th
digit (material) is other than V, A, B, C and
D.
)% / 28°C
x
See OUTLINE DIAGRAM.
10.5 to 13.5 kg
Mass:
Optical cable connection:
G1/2 or 1/2 -14NPT (whichever selected
by code symbol)
Process connection:
JIS specifications;
10K, 20K, 30K, 63K-40, 50A
Remarks:
(1) This is an output change when the process
pressure receiving unit and the transmitter
body are at the same height and temperature.
(2) Error is larger when there is a temperature
difference among the process pressure
receiving unit, capillary and transmitter body.
10K-80A, 100A
ANSI/JPI specifications;
150LB, 300LB, 600LB, 1-1/2B, 2B
150LB-3B, 4B
2
Fill-fluid: Silicon oil (Code: Y,G)
Fill-fluid: Silicon oil (Code: S)
Diaphragm extension:
0, 50, 100, 150 or 200 mm (as specified)
Mounting method:
U-bolt mounting to a 50A (2B) pipe. De-
[kPa abs]
Fill-fluid: Silicon oil (Code: T)
With
tection unit is mounted with flange or
between flanges (wafer type).
small bore
101
Orientation of transmission unit:
Operating area
53.3
Indicator unit turnable 90° upward/down-
ward relative to detection unit.
Capillary length: Max. 10 m
13.3
2.7
Max. 5 m for small bore 40A, 50A,
1-1/2B or 2B
Optional specifications
Non-operating area
Indication unit: 5-digit LCD indication, % or real scale in-
dication (as specified by code symbol)
Operating temperature range: –20 to
+70°C
-
40
-
15 0
60 85 120
Process temperature
200 230250
300
C]
[
°
Note: For use at a vacuum level, the transmitter body should be
mounted below the flange section mounting position.
Oxygen oil-proof processing:
Varies with
material.
Fluorolube filled.
Fig. 1 Relation between process temperature and
operating pressure
Wetted parts degreased
Refer to
and cleaned.
CODE
Chlorine service:Fluorolube oil filled.
SYMBOLS.
Fill-fluid: Silicon oil (Code: K)
[kPa abs]
101
Table 1 Remote Control Function
(Items readable and setting from hand-held
communicator)
Item
Reading Setting
Description
Operating area
Maximum range
Maximum measuring range
of equipment
Measuring range
Damping
Real scale
indication
Battery voltage
Error indication
Actual measuring range
Variable within 0.2 to 32 sec.
Indication in industrial value
Non-
operating
area
0.27
0.13
Battery voltage of equipment
Errors of detection unit and
amplifier
Measured data
Zero and span adjustment
-15
100
200
[°C]
Measured value
Adjustment
Process temperature
Note: For operation of the “3” type transmitter (“3” at the 8th digit
of product code), a hand-held communicator is required to
have a version 1.6 or higher, but a communicator before
version 1.6 can be operated with memory data updated.
(Refer to the instruction manual of transmitter.)
Fig. 2 Relation between process temperature and
operating pressure
SYSTEM BLOCK DIAGRAM
1:1 system
1 to 5V DC
Host system
4 to 20mA DC
Master station
Optical fiber type
electric converter
(Type; PSN)
Control room
Star coupler
Field
Transmitter
Transmitter
Field equipment
(max. 8 units)
Transmission distance: 1.5 km max.
(between master station and field equipment)
Transmission distance: 4 km max.
3
FBM···3
CODE SYMBOLS
1
2
3
4
5
6
7
8
9 10111213
Description
F B
M
3
F
Cable lead-in port (4th digit)
G1/2
1/2-14NPT
S
T
Flange (5th digit)
Code usable
at 6th digit
Code usable
at 7th digit
Rating
Material
0
1
3
JIS 10K 80A
1,2,3
1,2,3
1,2,3
1,2,3
3
3
3
3
3,4
3,4
3,4
3,4
3
3
3
3
3,4
3,4
All codes usable
P and R unusable
All codes usable
P and R unusable
V,H,M,T
V,A to D,H,M,T
V,H,M,T
V,A to D,H,M,T
V,H,M,T
V,A to D,H,M,T
V,H,M,T
V,A to D,H,M,T
V,H,M,T
V,A to D,H,M,T
V,H,M,T
V,A to D,H,M,T
V,H,M,T
JIS 10K 100A
ANSI/JPI 150LB 3B
ANSI/JPI 150LB 4B
JIS 10K 40A
JIS 10K 50A
JIS 20K 40A
JIS 20K 50A
JIS 30K 40A
JIS 30K 50A
JIS 63K 40A
JIS 63K 50A
ANSI/JPI 150LB 1 /2B
ANSI/JPI 150LB 2B
ANSI/JPI 300LB 1 /2B
ANSI/JPI 300LB 2B
ANSI/JPI 600LB 1 /2B
ANSI/JPI 600LB 2B
For JIS 80A, ANSI/JPI 3B 1,2,3
For JIS100A, ANSI/JPI 4B 1,2,3
SUS304
4
A
B
C
D
E
F
G
H
J
1
L
M
N
V
W
P
Q
R
S
K
1
1
V,A to D,H,M,T
All codes usable
P and R unusable
V,A to D,H,M,T
V,H,M,T
Wafer type
(without flange)
For JIS 50A, ANSI/JPI 2B 3,4
For JIS 40A, ANSI/JPI 1 /2
JIS G1 thread
1
B
3,4
4,5
Screw-in type
V
Measuring span (6th digit)
3.25.........130kPa
12.5...... 500kPa
1
2
3
4
5
75........ 3000kPa …Selectable when 7th digit is V, A, B, C, D, H, M or T.
250......10000kPa
1250....50000kPa
Must be specified for 5th code K.
7th digit must be V.
Material and diaphragm extension (7th digit)
Seal diaphragm
SUS316L
SUS316L
SUS316L
SUS316L
Other wetted parts Diaphragm extension (mm)
V
A
B
C
D
H
F
G
K
L
SUS316
0
SUS316
SUS316
SUS316
SUS316
Hastelloy-C
Hastelloy-C
Hastelloy-C
Hastelloy-C
Hastelloy-C
Monel
50
100
150
200
0
50
100
150
200
0
Only 5th codes 1, 4 and Q are
selectable when these codes
are used in combination
SUS316L
with 13th codes S, T or K.
Hastelloy-C
Hastelloy-C
Hastelloy-C
Hastelloy-C
Hastelloy-C
Monel
Tantalum
Titanium
Zirconium
M
T
P
R
Tantalum
Titanium
Zirconium
0
0
0
Selectable when 6th digit is
2 and 5th digit is 0, 3 or P.
Indicator (9th digit)
Not provided
Digital, % indication
Digital, real scale indication
A
L
P
Explosion-proof (10th digit)
Non-explosion proof
Intrinsic safety, JIS
A
G
4
1
2
3
4
5
6
7
8
9 10111213
Description
F BM
3
F
Capillary length (11th digit)
1.5m
3m
5m
A
B
C
G
H
J
6m.....Selectable when 5th digit is 0, 1, 3, 4, P or Q.
7m
Selectable when 5th digit is 0, 1, 3, 4, P or Q
8m
and 13th digit is Y, W, G, A or D.
10m
K
Treatment and fill-fluid (13th digit)
Treatment
None
None
Fill-fluid
Silicon oil
Fluorolube oil
Silicon oil
Y
W
G
Degreasing
Oxygen oil-proof processing Fluorolube oil.....ꢀwhen 7th digit is V, A, B, C or D
A
D
H
Chlorine service
None
None
Fluorolube oil.....ꢀwhen 7th digit is H, F, G, K, L or T
when 6th digit is 1, 2, 3, and
7th digit is V, A, B, C or D
Silicon oil (for high temperature)
Silicon oil (for high temperature)
Note 1 J
S
Note 1 T
Note 1 K
when 6th digit is 2,
and 7th digit is V, A,
B, C or D
None
None
None
Silicon oil (for high temperature and vacuum)
Silicon oil (for high temperature and vacuum)
Silicon oil (for high temperature and high vacuum)
Note 1: Inapplicable for small bores 40A, 50A, 1-1/2B and 2B.
5
FBM···3
OUTLINE DIAGRAM (Unit : mm)
0 C J
1 D L 1
3 EM 2
4 F N 3
A G V 4
B HW
FBM
3
S: Capillary length
φF
S
Mounting pipe
JIS 50A (2B)
241
Inside diameter
of gasket seat
80
108
70
φK
φJ
φH
U-bolt
(M8)
315
54
N-φh
15
hole
Indicator (option)
B
37 27
47
φG
Optical cable lead-in port
φ15
E
Type
FBMS
FBMT
G1/2
1/2-14NPT
Type
φF φG φH φJ φK
t
P
N-φh
FLANGE
E
FBM*0**3 185 150 126 100 73 38 116 8-19 JIS-10K-80A
FBM*1**3 210 175 151 103 96 38 141 8-19 JIS-10K-100A
FBM*3**3 191 152.5 126 100 73 44 116 4-20 ANSI/JPI 150lB 3B
FBM*4**3 229 190.5 151 103 96 44 141 8-20 ANSI/JPI 150lB 4B
FBM*A**3 140 105 84 49 48 36 71 4-19 JIS-10K-40A
FBM*B**3 155 120 84 49 48 36 71 4-19 JIS-10K-50A
FBM*C**3 140 105 84 49 48 38 71 4-19 JIS-20K-40A
FBM*D**3 155 120 84 49 48 38 71 8-19 JIS-20K-50A
FBM*E**3 160 120 84 49 48 42 71 4-23 JIS-30K-40A
FBM*F**3 165 130 84 49 48 42 71 8-19 JIS-30K-50A
FBM*G**3 175 130 84 49 48 52 71 4-25 JIS-63K-40A
FBM*H**3 185 145 84 49 48 54 71 8-23 JIS-63K-50A
FBM*J**3 127 98.4 84 49 48 37.5 71 4-16 ANSI/JPI 150LB 11/
FBM*L**3 152 120.6 84 49 48 39.5 71 4-20 ANSI/JPI 150LB 2B
FBM*M**3 156 114.3 84 49 48 41 71 4-23 ANSI/JPI 300LB 11/
FBM*N**3 165 127 84 49 48 42.5 71 8-20 ANSI/JPI 300LB 2B
FBM*V**3 156 114.3 84 49 48 42.5 71 4-23 ANSI/JPI 600LB 11/
FBM*W**3 165 127 84 49 48 45.5 71 8-20 ANSI/JPI 600LB 2B
Note) For S (capillary length), refer to CODE SYMBOLS.
Details of "B"
L
0
Mass (kg)
Type
FBM***V3
FBM***H3
FBM***M3
FBM***T3
FBM***P3
FBM***R3
10.5
FBM***A3
50
11.5
12.5
13
FBM***F3
2
B
B
B
FBM***B3
FBM***G3
100
150
200
FBM***C3
2
FBM***K3
FBM***D3
FBM***L3
13.5
2
6
P 1
Q 2
R 3
S 4
FBM
3
315
20
54
Type
φH φJ
P
FLANGE
37 27
47
126 100 116 80A, 3B
151 103 141 100A, 4B
FBM*P**3
FBM*Q**3
FBM*R**3
FBM*S**3
84 49 71 50A, 2B
2-M6, depth 9
1
84 49 71 50A, 1 /
2B
for flange mounting
4
5
FBM
K
V3
S
Mounting pipe
JIS 50A (2B)
241
80
108
70
U-bolt
(M8)
315
54
Packing
15
Indicator (option)
G1
B
37 27
47
Optical cable lead-in port
φ15
2
2
18
53
E
Type
45
20
F B M S
F B M T
G1/2
100
1/2-14NPT
E
Note) For S, refer to CODE SYMBOLS.
Details of "B"
7
FBM···3
SCOPE OF DELIVERY
Instrument body and pipe fixture (as specified)
ORDERING INFORMATION
1. Model type
2. Measuring range
3. Indication scale for real scale specification
4. Others
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Head Office
6-17, Sanbancho, Chiyoda-ku, Tokyo 102-0075, Japan
http://www.fesys.co.jp/eng
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202 Fax: 81-42-585-6187
http: //www.fic-net.jp/eng
Printed in Japan
Information in this catalog is subject to change without notice.