EDS6-132F [FUJI]

HYBRID ULTRASONIC FLOWMETER (PULSE">(Pulse Doppler method Transit Time method); 混合式超声波流量计(脉冲“ \u003e (脉冲多普勒法渡越时间法)
EDS6-132F
型号: EDS6-132F
厂家: FUJI ELECTRIC    FUJI ELECTRIC
描述:

HYBRID ULTRASONIC FLOWMETER (PULSE">(Pulse Doppler method Transit Time method)
混合式超声波流量计(脉冲“ \u003e (脉冲多普勒法渡越时间法)

脉冲
文件: 总12页 (文件大小:540K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HYBRID ULTRASONIC FLOWMETER <Duosonics>  
(Pulse Doppler method +TransitTime method)  
DATA SHEET  
FSH, FSW, FLY  
Thismeteristheworldsrstnon-intrusivetypeultrasonicꢀ  
flowmeterutilizingPulseDopplermethodalongwithꢀTransitꢀ  
Timemethod.Itenablesmeasurementofvelocityprofileꢀ  
directlyresultinginhighaccuracy.ꢀThismakesitsuitableforꢀ  
undevelopedflowandforshortstraightpipes.PulseDop-  
plerꢀmethodꢀrequiresꢀreflectorsꢀinꢀtheꢀliquidꢀandꢀisꢀutilizedꢀonꢀ  
opaqueꢀliquidsꢀwhileTransitTimeꢀmethodꢀrequiresꢀultrasoundꢀ  
penetrationandisidealforcleanliquids.ꢀThenewhybridꢀ  
technologyutilizesbothmethodsinacomplementaryfash-  
ionꢀthusꢀenablingꢀaꢀwiderꢀrangeꢀofꢀapplicationsꢀthanꢀitꢀisꢀpos-  
siblenow.Inaddition,thankstoFuji’snewstate-of-the-artꢀ  
algorithm,eithermethodcanbeautomaticallyswitchedtoꢀ  
accommodateꢀforꢀvaryingꢀfluidꢀconditionsꢀsuchꢀasꢀconcentra-  
tionꢀofꢀparticlesꢀand/orꢀairꢀbubblesꢀandꢀflowꢀvelocity.ꢀ  
Flow transmitter  
(FSH)  
FEATURES  
Detector  
(FSW)  
1. Automatic switchover function between Pulse Doppler  
method utilizing ultrasound reflection andTransitTime  
method utilizing ultrasound penetration  
•ꢀApplicableꢀtoꢀvariousꢀkindsꢀofꢀliquidsꢀwith/withoutꢀairꢀ  
bubblesꢀand/orꢀsolidꢀparticles  
Application:ꢀ Uniformliquidinwhichultrasonicwavescanꢀ  
propagate.ꢀ  
•ꢀApplicableꢀtoꢀliquidꢀflowꢀthatꢀchangesꢀinꢀnatureꢀfrequent-  
lyꢀorꢀperiodically  
Airꢀbubbleꢀquantity:ꢀ PulseꢀDopplerꢀmethod:ꢀ0.02ꢀtoꢀ  
15%ꢀofꢀvolumeꢀatꢀ1ꢀm/s  
2. High-accuracy non-intrusive (non-contact) volumetric  
flow rate measurement of liquid flow in closed pipes.  
Transitꢀtimeꢀmethod:ꢀ0ꢀtoꢀ12%ꢀ  
ofꢀvolumeꢀatꢀ1ꢀm/s  
•ꢀAccuracyꢀofꢀ0.5%ꢀtoꢀ1%ꢀ(dependingꢀonꢀtheꢀmeasuringꢀ  
modeꢀandꢀpipeꢀsize)  
•ꢀClamp-onꢀsensor  
Fluidꢀtemperature:ꢀꢀ -40ꢀtoꢀ+100ºCꢀ(FSW12),ꢀ-40ꢀtoꢀ  
80ºCꢀ(FSW21,ꢀFSW40,FSW50)  
3. Direct measurement of velocity profile in case of Pulse  
Doppler method  
Typeꢀofꢀflow:ꢀ  
PulseDopplerꢀmethod:ꢀaxi-  
symmetricꢀflowꢀinꢀaꢀfilledꢀpipe.  
Transitꢀ timeꢀ method:ꢀ well-  
developedꢀturbulentꢀorꢀlaminarꢀ  
flowꢀinꢀaꢀfilledꢀpipe.  
•ꢀHighꢀaccuracyꢀofꢀ0.5%ꢀtoꢀ1.5%ꢀ(correctionꢀcoefficientꢀ  
unnecessary)  
•ꢀApplicableꢀtoꢀundevelopedꢀflowꢀ(shortꢀstraightꢀpipe)  
•ꢀApplicableꢀtoꢀflowꢀhoveringꢀinꢀtheꢀtransitionalꢀregionꢀ  
betweenꢀlaminarꢀflowꢀandꢀturbulentꢀflowꢀ  
Applicable flow pipe:  
Material:ꢀ  
Plasticsꢀ (PVC,ꢀ FRP,ꢀ etc.)ꢀ orꢀ  
Metals(carbonsteel,SS,cop-  
per,ꢀaluminum,ꢀetc.)  
4. High speed response: 0.2sec (pulse Doppler method)/  
0.5sec (transit time method)  
5. Real time monitoring of velocity profile by PC in case  
of Pulse Doppler method (option)  
Pipeꢀsize:ꢀꢀ  
40ꢀtoꢀ1000ꢀmm  
(insideꢀdiameter)  
6. Dual-path option improves performance  
Liner:ꢀꢀ  
Tarꢀepoxy,ꢀmortar,ꢀetc.ꢀ  
Straightꢀpipeꢀlength:ꢀ Typicallyꢀ10Dꢀforꢀupstreamꢀandꢀ  
5Dfordownstream.Refertoꢀ  
JEMIS-032ꢀinꢀdetail.  
SPECIFICATIONS  
Operational specifications  
(Note)JEMIS:JapanElectricꢀ  
MeasuringInstrumentsꢀ  
System configuration:  
Thesystemiscomposedofone/twodetec-  
tors(Model:FSW)andoneFlowtransmitterꢀ  
(Model:FSH),realizingsingle-path/two-pathꢀ  
measurement.ꢀ  
Hybridmodeortransittimemodeisselect-  
able.  
Manufactures'Associa-  
tionsꢀStandard  
Hybridꢀmode:ꢀ0ꢀtoꢀ 0.3ꢀ---ꢀ MaximumꢀVeloc-  
ityꢀ(dependingꢀonꢀpipeꢀdiameter)ꢀ(Note)ꢀMaxi-  
mummeasurementrangeinHybridmodeꢀ  
(seeꢀpageꢀ4)  
Velocity:ꢀ  
Incaseofhybridmode,etherPulseDopplerꢀ  
methodortransittimemethodisautomati-  
callyselecteddependingonconditionsofꢀ  
measuredꢀliquidꢀandꢀmagnitudeꢀofꢀvelocity.  
Transitꢀtimeꢀmode:ꢀ0ꢀtoꢀ 0.3ꢀ---ꢀ 32ꢀm/s  
Power supply:  
100ꢀtoꢀ240ꢀVac+10%/-15%,ꢀ50/60Hzꢀorꢀ20ꢀtoꢀ  
30ꢀVdc  
EDS6-132f  
Date  
Apr. 1, 2011  
FSH, FSW, FLY  
Signal cable:ꢀ Single-pathꢀsystemꢀ:ꢀ  
Digital output:+total,ꢀ-total,ꢀalarm,ꢀactingꢀrange,ꢀflowꢀswitchꢀ  
orꢀtotalꢀswitchꢀ--ꢀarbitrarilyꢀselectable  
Mechanicalꢀrelayꢀcontact:ꢀ  
ApairofRFco-axialcablesforultrasoundꢀ  
signalsꢀandꢀaꢀthree-coreꢀshieldꢀcableꢀforꢀtem-  
peratureꢀsensor,  
Two-pathsystem:ꢀTwopairsofRFco-axialꢀ  
cablesꢀforꢀultrasoundꢀsignalsꢀandꢀaꢀthree-coreꢀ  
shieldꢀcableꢀforꢀtemperatureꢀsensor,  
Maximumꢀcableꢀlength:ꢀ150m  
1ꢀpointꢀwithꢀsocketꢀ(replaceable)  
Normallyꢀclosed/openꢀselectable  
Capacity:240ꢀVac/30ꢀVdc,ꢀ1ꢀAꢀ  
Totalꢀpulse:ꢀlessꢀthanꢀ1ꢀp/sꢀ  
(Pulsewidth:50,100or200msꢀ  
selectable)  
Temperatureꢀrange:ꢀ80ºC  
Environment:ꢀNon-explosiveenvironmentwithoutdirectꢀ  
sunlight,ꢀcorrosiveꢀgasꢀandꢀheatꢀradiation  
Ambient temperature:  
Transistorꢀopenꢀcollector:ꢀ2ꢀpoints  
Capacity:ꢀ30ꢀVdc,ꢀ0.1ꢀA  
Normallyꢀoff/onꢀselectable  
-10ꢀtoꢀ+50ºCꢀforꢀflowꢀtransmitter,ꢀ  
-20ꢀtoꢀ+80ºCꢀforꢀdetector  
Ambient humidity:  
95%RHꢀorꢀlessꢀforꢀflowꢀtransmitter,ꢀ100%RHꢀ  
orꢀlessꢀforꢀdetector  
Grounding:ꢀ ClassꢀDꢀ(lessꢀthanꢀ100ꢀohm)  
Totalꢀpulse:ꢀlessꢀthanꢀ1000ꢀp/sꢀ  
(Pulsewidth:ꢀ0.5,ꢀ1,ꢀ2,ꢀ5,ꢀ10,20,ꢀ  
50,ꢀ100ꢀorꢀ200ꢀmsꢀselectable)  
Communication interface:  
RS-232Cꢀequivalentꢀ/ꢀRS-485ꢀ(selectable)  
Numberꢀofꢀconnectableꢀunits:ꢀoneꢀ(RS-232C)/  
upꢀtoꢀ31ꢀ(RS-485)  
Baudꢀrate:ꢀ9600/19200/38400ꢀbpsꢀselectable  
Parity:ꢀnone/odd/evenꢀselectable  
Stopꢀbit:ꢀ1ꢀorꢀ2ꢀbitsꢀselectable  
Distance:upto15m(RS-232C)/upto1kmꢀ  
(RS-485)  
Arrester:ꢀ  
Surgeꢀabsorbersꢀforꢀoutputsꢀandꢀpowerꢀsupplyꢀ  
incorporatedꢀasꢀstandard  
Performance specifications  
Accuracy :  
Data:velocity,owrate,+total,-total,statusꢀ  
(standard),ꢀvelocityꢀprofileꢀ(option)  
Display device:  
Pulse Doppler method :  
ꢀꢀPipeꢀsizeꢀ(insideꢀdiameter) Velocity  
ꢀꢀandꢀdetector  
Accuracy  
GraphicꢀLCDꢀ(numberꢀofꢀpixels:ꢀ240x64)ꢀwithꢀ  
backꢀlight,ꢀ  
φ40mmꢀtoꢀφ50mmꢀorꢀless 1.5ꢀm/sꢀto  
1.0%ꢀofꢀrate  
Display language:  
ꢀ (Detector:ꢀFSWS12)  
Max.ꢀVelocityꢀ(Note)  
Japanese,English,French,GermanorSpan-  
ishꢀselectable  
Velocity/Flow rate display:  
0ꢀm/sꢀtoꢀ1.5ꢀm/s  
0.015m/s  
φ50mmꢀtoꢀφ200mmꢀ  
ꢀ (Detector:ꢀFSWS12)  
1.5ꢀm/sꢀto  
0.5%ꢀofꢀrate  
Max.ꢀVelocityꢀ(Note)  
Displayꢀofꢀvelocityꢀand/orꢀflowꢀrateꢀwithꢀflowꢀ  
direction  
Data:upto10digitsꢀ(decimalꢀpointꢀtoꢀbeꢀ  
countedꢀasꢀ1ꢀdigit)  
0ꢀm/sꢀtoꢀ1.5ꢀm/s  
1ꢀm/sꢀto  
0.0075m/s  
φ100mmꢀtoꢀφ1000mmꢀ  
1.0%ꢀofꢀrate  
ꢀ (Detector:ꢀꢀFSWS21,40,50) Max.ꢀVelocityꢀ(Note)  
Unit:ꢀMetric/Englishꢀsystemꢀselectable  
0ꢀm/sꢀtoꢀ1ꢀm/s  
0.01m/s  
(Note)ꢀ Maximumꢀvelocityꢀisꢀdependꢀonꢀaꢀpipeꢀdiameter.  
Metricꢀsystemꢀ  
m/sꢀ  
Englishꢀsystem  
ft/s  
ft3/s,ꢀft3/min,ꢀft3/h,ꢀMft3/d,ꢀ  
gal/s,ꢀgal/min,ꢀgal/h,ꢀMgal/d,ꢀ  
BBL/s,ꢀBBL/min,ꢀBBL/h,ꢀ  
BBL/d,ꢀkBBL/d,ꢀMBBL/d  
SeeꢀMaximumꢀmeasurementꢀrangeꢀinꢀHybridꢀmodeꢀꢀ(pageꢀ4).  
ꢀVelocityꢀ  
ꢀFlowꢀrate  
Transit time method :  
L/s,ꢀL/min,ꢀL/h,ꢀL/d,ꢀkL/h,ꢀ  
ML/d,ꢀm3/s,ꢀm3/min,ꢀm3/h,ꢀ  
m3/d,ꢀkm3/d,ꢀMm3/d,ꢀ  
BBL/s,ꢀBBL/min,ꢀBBL/h,ꢀ  
kBBL/d,ꢀMBBL/d  
Pipeꢀsizeꢀ(insideꢀdiameter)ꢀ Velocity  
Accuracy  
1.5%ꢀofꢀrate  
0.03m/s  
φ40mmꢀtoꢀφ50mmꢀorꢀless  
φ50mmꢀtoꢀφ300mmꢀorꢀless  
φ300mmꢀtoꢀφ1000mm  
2ꢀm/sꢀtoꢀ32ꢀm/s  
0ꢀm/sꢀtoꢀ2ꢀm/s  
2ꢀm/sꢀtoꢀ32ꢀm/s  
0ꢀm/sꢀtoꢀ2ꢀm/s  
1ꢀm/sꢀtoꢀ32ꢀm/s  
0ꢀm/sꢀtoꢀ1ꢀm/s  
1.0%ꢀofꢀrate  
0.02m/s  
Note:ꢀ˝gal˝ꢀmeansꢀUSꢀgal.  
1.0%ꢀofꢀrate  
0.01m/s  
Total display:ꢀ Displayꢀofꢀforwardꢀorꢀreverseꢀtotal  
Data:ꢀupto10digitsꢀ(decimalꢀpointꢀtoꢀbeꢀ  
countedꢀasꢀ1ꢀdigit)  
Unit:ꢀ Metric/Englishꢀsystemꢀselectableꢀ  
Response time:  
PulseꢀDopplerꢀmethod:ꢀ 0.2sec  
(dependingꢀonꢀpipeꢀdiameterꢀandꢀ  
measuringꢀcondition)  
Transitꢀtimeꢀmethod:ꢀ 0.5sec  
Power consumption:  
20Wꢀorꢀless  
Short-term thermal stability:  
140ºC,ꢀ30ꢀminꢀ(FSWS12),  
100ºC,ꢀ30ꢀminꢀ(FSWS21,ꢀFSWS40,ꢀFSWS50)  
Metricꢀsystemꢀ  
Englishꢀsystem  
ft3,ꢀkft3,ꢀMft3,ꢀgal,ꢀkgal,ꢀ  
mL,ꢀL,ꢀm3,ꢀkm3,ꢀMm3,ꢀ  
ꢀTotal  
mBBL,ꢀBBL,ꢀkBBL,ꢀACRf  
mBBL,ꢀBBL,ꢀkBBL  
Configuration:  
Fullyconfigurableꢀonꢀkeyboardꢀbyꢀmenu-  
drivenꢀsoftwareꢀ  
Zero adjustment:  
Setꢀzero/Clearꢀavailable.ꢀ(transitꢀtimeꢀmethod)  
Damping:ꢀ  
0ꢀtoꢀ100sꢀ(everyꢀ0.1s)ꢀconfigurableꢀforꢀanalogꢀ  
outputꢀandꢀdisplay  
Functional specifications  
Low flow cut off:ꢀ  
0ꢀtoꢀ5ꢀm/sꢀconfigurable  
Analog output:4ꢀtoꢀ20ꢀmAdcꢀ(1ꢀpoint)  
Max.ꢀloadꢀresistance:ꢀ1kꢀohm  
2
Alarm:ꢀ  
Hardwarefault/processfaultcanbetiedtoꢀ  
digitalꢀoutput  
Acoustic coupler:  
Siliconꢀcompoundꢀ(RTV)  
Burnout:  
Analogꢀoutput:ꢀꢀHold/Upperlimit/Lowerlimit/  
Zero/Not-usedꢀselectable  
Total:ꢀꢀꢀHold/Countꢀselectable  
Material:ꢀ  
FlowTransmitter:ꢀaluminumꢀalloy  
Detector:ꢀPBTꢀforꢀhousing,ꢀaluminumꢀalloyꢀforꢀ  
frameꢀandꢀSSꢀforꢀfasteningꢀbelt  
Timer:ꢀ0ꢀtoꢀ900sꢀ(everyꢀ1s)ꢀconfigurableꢀꢀ  
Bi-directional range:  
Forwardandreverserangesconfigurablein-  
Sensor cable(FLY6):  
RFꢀcoaxialꢀcableꢀ(doubleꢀshielded)ꢀ  
Externalꢀsheath:ꢀBlackꢀflame-resistantꢀvinylꢀ  
Externalꢀdiameter:ꢀAboutꢀ7.3ꢀmm  
Terminalꢀtreatment:ꢀWater-resistantꢀBNCꢀcon-  
nector(detectorside),M3.5amplifierꢀ  
terminalꢀ(FlowTransmitterꢀside)ꢀ  
dependently  
Hysteresis:0to20%ofworkingrangecon-  
figurable  
Workingꢀrangeꢀapplicableꢀtoꢀdigitalꢀoutput  
Auto-2 ranges:  
Weight:ꢀAboutꢀ90ꢀg/mꢀ  
Forwardꢀ2ꢀrangesꢀconfigurableꢀindependently  
Hysteresis:0to20%ofworkingrangecon-  
figurable  
Temperature sensor cable(FLY7):  
3-coreꢀshieldꢀcable  
Externalꢀsheath:ꢀGrayꢀflame-resistantꢀvinylꢀ  
Externalꢀdiameter:ꢀAboutꢀ6.9ꢀmm  
Terminaltreatment:Roundwaterproofcon-  
nector(detectorside),M3.5amplifierꢀ  
terminalꢀ(FlowTransmitterꢀside)ꢀ  
Weight:ꢀAboutꢀ56ꢀg/m  
Workingꢀrangeꢀapplicableꢀtoꢀdigitalꢀoutput  
Flow switch:ꢀ Lowerandupperswitchingpointsconfigu-  
rableꢀindependently  
Actingꢀpointꢀapplicableꢀtoꢀdigitalꢀoutput  
Total switch:ꢀ +totalꢀswitchingꢀpointꢀconfigurable  
Actingꢀpointꢀapplicableꢀtoꢀdigitalꢀoutput  
Dimensions:ꢀ FlowTransmitterꢀ:ꢀH240ꢀxꢀW247ꢀxꢀD134ꢀmm  
Detector:ꢀH70ꢀxꢀW57ꢀxꢀL360ꢀmmꢀ(FSWS12)  
H72ꢀxꢀW57ꢀxꢀL540ꢀmmꢀ(FSWS21)  
Physical specifications  
Enclosure protection:  
FlowTransmitter:ꢀIP67,ꢀ  
Detector:ꢀIP67  
H90ꢀxꢀW85ꢀxꢀL640ꢀmmꢀ(FSWS40)  
H82ꢀxꢀW71ꢀxꢀL258ꢀmmꢀ(FSWS50)  
Mounting:ꢀ  
FlowTransmitter:ꢀwallꢀmount  
Mass:ꢀ  
FlowTransmitter:ꢀ5ꢀkg  
Detector:ꢀclampedꢀonꢀpipeꢀsurface  
Detector:ꢀ1.7ꢀkgꢀ(FSWS12),ꢀ1.9ꢀkgꢀ(FSWS21),ꢀ  
5ꢀkgꢀ(FSWS40),ꢀ1.5ꢀkgꢀ(FSWS50)  
Conditions on straight pipe  
( D : Inside diameter of pipe)  
Classification  
Upstream side  
Downstream side  
5D  
L
L
10D  
90 bend  
Detector  
L
L
10D  
50D  
Tee  
10D or more  
L
5D  
L
30D  
Diffuser  
1.5D  
L
5D  
L
10D  
Reducer  
L
30D  
L
10D  
Various Valve  
In case that flow control valve exists on  
upstream side.  
In case that flow control valve exists on  
downstream side.  
Stop valve  
Check valve  
L
50D  
Pump  
P
(Note)The source : JEMIS-032  
3
FSH, FSW, FLY  
Measurement principle  
Block diagram  
<Pulse Doppler method>  
(1) Single path system (Z method)  
•ꢀ Ultrasoundpulsesaretransmittedintoaliquid,andꢀ  
flowvelocityprofileisfoundandtheflowrateisꢀ  
measuredbyusingthecharacteristicsthatDopplerꢀ  
frequencyoftheechofromreflectorssuchasairꢀ  
bubblesꢀandꢀparticlesꢀinꢀtheꢀliquidꢀchangesꢀaccordingꢀ  
toꢀflowꢀvelocity.  
Cable  
Power  
supply  
Detector  
Flow  
4 to 20mA DC  
Contact  
Transmitter  
Sensor 1  
(Up to 3 points  
are allowed.)  
Temperature  
sensor cable  
Air  
Flow  
bubbles  
Reflection  
(2) 2-path system (Z method)  
Sensor 2  
Flow  
Flow  
Power  
supply  
velocity  
Profile 2  
velocity  
Profile 1  
Cable  
Detector  
Flow velocity  
4 to 20mA DC  
Flow  
Transmitter  
Piping wall  
Center  
Piping wall  
Contact  
(Up to 3 points  
are allowed.)  
<TransitTime method>  
•ꢀ Ultrasoundpulsesarepropagatedslantedbothfromtheꢀ  
upstreamꢀandꢀdownstream,ꢀandꢀflowꢀrateꢀisꢀmeasuredꢀbyꢀ  
detectingꢀtheꢀtimeꢀdifferenceꢀgeneratedꢀwithꢀtheꢀflow.  
Temperature  
sensor cable  
Sensor 1  
Flow  
Sensor 2  
Transmission  
1
Receiving  
Sensor 2  
Sensor 1  
2
Time difference T  
Maximum measurement range in hybrid mode  
When stainless steel is selected as pipe material, nominal wall thickness is Sch20s, and the fluid is water  
<Maximum measurable flow velocity> <Maximum measurable flow rate>  
Unit: m3/h  
Unit: m/s  
FSWS50  
Caliber  
40A  
FSWS12  
6.56  
FSWS21  
FSWS40  
FSWS12  
33.6  
52.7  
72.1  
86.5  
102  
FSWS21  
FSWS40  
FSWS50  
50A  
65A  
80A  
6.52  
5.31  
4.65  
4.12  
90A  
100A  
125A  
150A  
200A  
250A  
300A  
350A  
400A  
450A  
500A  
550A  
600A  
650A  
700A  
750A  
800A  
850A  
900A  
1000A  
3.69  
3.08  
2.63  
2.04  
7.25  
6.08  
5.20  
4.05  
3.30  
2.78  
2.51  
2.20  
118  
147  
179  
239  
231  
289  
354  
474  
604  
735  
820  
951  
7.77  
6.38  
5.41  
4.90  
4.31  
3.80  
3.48  
908  
1168  
1428  
1598  
1858  
2118  
2358  
3.48  
3.17  
2.91  
2.71  
2.52  
2.35  
2.21  
2.08  
1.97  
1.77  
2358  
2618  
2879  
3096  
3357  
3618  
3879  
4140  
4400  
4902  
4
CODE SYMBOLS  
<Flow transmitter>  
<Signal cable>  
1
2
3
4
5
6
7
8
9
10 11 12  
1
2
3
4
5
6
7
8
1
S
Description  
Type (4th digit)  
1
Description  
Kind of cable (4th digit)  
Coaxial cable (for ultrasonic sensors)  
Three-core cable (for temperature sensor)  
F S H  
Y
Y Y  
F L Y  
E
6
7
Standard  
Velocity profile output (5th digit)  
None  
Available  
Cable length (5th to 7th digit)  
5m  
Y
A
0 0 5  
0 1 0  
0 1 5  
0 2 0  
0 2 5  
0 3 0  
0 3 5  
0 4 0  
0 4 5  
0 5 0  
0 5 5  
0 6 0  
0 6 5  
0 7 0  
0 7 5  
0 8 0  
0 8 5  
0 9 0  
0 9 5  
1 0 0  
1 1 0  
1 2 0  
1 3 0  
1 4 0  
1 5 0  
10m  
15m  
20m  
25m  
30m  
35m  
40m  
45m  
50m  
55m  
60m  
65m  
70m  
75m  
80m  
85m  
90m  
95m  
100m  
110m  
120m  
130m  
140m  
150m  
Use (6th digit)  
Single path or Changeover two-path (Note)  
Y
Note: 2 sets of detectors and coaxial cables  
(FLY6) needed for two-path system.  
Power supply (7th digit)  
100 to 240 Vac, 50/60 Hz  
20 to 30 Vdc  
1
4
Modification No. (8th digit)  
Mark 1  
1
Case structure (9th digit)  
IP67  
S
Conduit connection (10th digit)  
G1/2 and G3/8 (female screw) with  
water-proof connection  
Y
For use with explosion-proof detector  
(11th digit)  
Y
None  
Parameter setting, Tag Plate (12th digit)  
None  
With setting  
With setting and Tag Plate  
With Tag Plate  
Y
A
B
C
Length in m to be designated with 3 digits  
Modification No. (8th digit)  
1
Mark 1  
Loader software for PCs  
Equippedꢀasꢀstandard  
<Detector>  
1
2
3
4
5
6
7
8
9
10 11  
•ꢀ WorksꢀonꢀPC/ATꢀcompatibleꢀmachines.  
•ꢀ OperationonPC98-seriesmachines(NEC)cannotbeꢀ  
guaranteed.  
•ꢀ Operationonself-madePCsorshop-brandPCscannotꢀ  
beꢀguaranteed.  
1
Description  
F S W S  
0
Y
Type (4th digit)  
S
Standard  
Kind of detector (5th and 6th digit)  
Small diameter detector (φ 40 to 200 mm)  
Small size detector (φ 100 to 400 mm)  
Middle size detector (φ 200 to 500 mm)  
Large size detector (φ 500 to 1000mm)  
1 2  
2 1  
4 0  
5 0  
•ꢀ Majorfunctions:Setting/changingofvariousparametersꢀ  
forꢀtheꢀmainꢀunit  
Ifꢀnoꢀflowꢀvelocityꢀprofileꢀoutputꢀisꢀselected,ꢀ  
theꢀfollowingꢀfunctionsꢀareꢀnotꢀavailable.  
”Detailedsetting”andflowvelocityprofileꢀ  
display”ꢀinꢀpulseꢀDopplerꢀmeasurement  
”Detailedsetting”andrecevedsignaldis-  
play”ꢀinTransitꢀtimeꢀmeasurement  
Use (7th digit)  
Standard (IP67)  
0
Modification No. (8th digit)  
Mark 1  
1
Signal cable (9th digit)  
None  
Y
Acoustic coupler (10th digit) (Note)  
None  
Silicone compound  
•ꢀ ꢀO/S:ꢀWindows2000/XP  
Y
A
•ꢀ Memoryꢀrequirement:ꢀ128MBꢀorꢀmore  
•ꢀ Diskꢀunit:ꢀWindows2000/XP-compatibleꢀCD-ROMꢀdrive  
•ꢀ Hardꢀdiskꢀdriveꢀcapacity:ꢀFreeꢀspaceꢀofꢀ52MBꢀorꢀmore  
N o t e :ꢀ ꢀ P Cꢀ l o a d e rꢀ c o m m u n i c a t i o nꢀ c a b l eꢀ ( t y p eꢀ  
ZZP*TK4H6253,Specifications:D-sub9pinreceptacle,ꢀ  
cableꢀlengthꢀ3m)ꢀisꢀseparatelyꢀrequired.  
Option (11th digit)  
None  
Tag Plate  
Y
A
(Note) Select silicone compound (A) for acoustic  
coupler in ordinary cases. Silicon compound is  
supplied in a tube (150g). If one or more  
detectors one ordered, silicon compound may  
be selected onece every 5 orders or so.  
Detector frame installation fixture  
Installationꢀfixtureꢀisꢀprovidedꢀtoꢀfacilitateꢀtheꢀpositioningꢀofꢀ  
theꢀframeꢀtoꢀtheꢀpiping.  
Selectadesiredtypefromthefollowingaccordingtotheꢀ  
detectorꢀtoꢀbeꢀused.  
Type  
Applicable detector  
FSWS12  
ZZP TK7M7071C1  
ZZP TK7M7071C2  
ZZP TK7M7071C3  
FSWS21  
FSWS40  
Note: The installation fixture cannot be used for detector type  
FSWS50, which is not provided with a frame.  
5
FSH, FSW, FLY  
(Unit:mm)  
OUTLINE DIAGRAM  
<Flow transmitter (type: FSH)>  
Mtg. plate  
Duosonics  
3
134  
72  
14  
233  
30 30 30  
48 48  
24  
48  
CONNECTION DIAGRAM  
Power supply terminals (AC)  
1
L
2
N
3
4
1
2
3
4
5
6
7
8
9
B
B
A
+
100 to 240V AC  
SERIAL  
SERIAL  
Iout  
Power supply terminals (DC)  
Cable  
(Black)  
Cable  
(Black)  
Cable  
(Yellow/  
Green)  
Communication cable  
(option)  
No.  
RS485  
TRX2 (  
TRX1 (  
SHILD  
RS232C  
1
+
2
3
4
4
5
6
)
TXD  
RXD  
COM  
Cap (red)  
Cap (yellow)  
Cap (black)  
+)  
To temp sensor  
20 to 30V DC  
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
HF GND HF GND HF GND HF GND  
+
+
+
UP STR DOWN STR UP STR DOWN STR  
DO1  
DO2  
DO3  
Relay contact  
LINE1  
LINE2  
Open collector  
* Use LINE1 terminals in case of single measuring path.  
6
(Unit:mm)  
OUTLINE DIAGRAM  
<Detector (type: FSWS12, 21)>  
Absorber unit  
Connector  
Sensor unit  
(with Temp. sensor)  
Cursor  
Temp. sensor  
Frame  
L
(H)  
Sensor unit  
(without Temp. sensor)  
TYPE  
PIPE SIZE  
ø40ø200  
ø100ø400  
L
H
W
57  
57  
MASS APPROX  
FSWS12  
FSWS21  
360  
540  
70  
72  
1.7  
1.9  
<Detector (type: FSWS40)>  
Absorber unit  
Connector  
Sensor unit  
(with Temp. sensor)  
Cursor  
Frame  
Temp. sensor  
640  
(90)  
Sensor unit  
(without Temp. sensor)  
7
FSH, FSW, FLY  
(Unit:mm)  
OUTLINE DIAGRAM  
<Detector (type: FSWS50)>  
BNC Connector  
Temp sensor  
Sensor unit  
Absorber unit  
258  
82  
8
<Signal cable (type: FLY6)>  
<Signal cable (type: FLY7)>  
φ15  
φ21.5  
BNC Connector  
Connector  
φ11  
φ7.3  
φ6.9  
L:ꢀAccordingꢀtoꢀtheꢀdesignationꢀofꢀtheꢀ5th,ꢀ6th,ꢀandꢀtheꢀ7thꢀ  
digitsꢀofꢀtheꢀCodeꢀSymbols.  
<Loader cable: ZZP*TK4H6253>  
Connector  
34  
To personal computer  
SCOPE OF DELIVERY  
Flowꢀtransmitterꢀ(Type:ꢀFSH):  
ꢀ ꢀ ꢀ  
ꢀ ꢀ ꢀ  
ꢀ ꢀ ꢀ  
Flowꢀtransmitter  
CD-ROMꢀ(Instructionꢀmanual,ꢀ  
Loaderꢀsoftware)  
Detectorꢀ(Type:ꢀFSW):ꢀ  
ꢀ ꢀ ꢀ  
ꢀ ꢀ ꢀ  
Sensorꢀunit  
Mountingꢀbelt  
Siliconꢀcompoundꢀ(option)  
φ6.9  
Signalꢀcableꢀ(Type:ꢀFLY6):ꢀ Cableꢀ(2ꢀwires)  
To Flow transmitter  
Signalꢀcableꢀ(Type:ꢀFLY7):ꢀ Cableꢀforꢀtemperatureꢀsensorꢀ(1)  
Terminal cap  
(Red)  
Terminal cap (Yellow)  
Terminal cap (Black)  
ITEMS DESIGNATED ORDERING  
Black  
COM  
Red Yellow  
TXD RXD  
Flowꢀtransmitterꢀcodeꢀsymbols  
Detectorꢀcodeꢀsymbols  
Signalꢀcableꢀcodeꢀsymbols  
RS-232C  
9
FSH, FSW, FLY  
<Parameter specification table>  
No.  
1
Setting item  
Settable range  
Initial value  
60.00mm  
Settable value  
Outer diameter  
10.00 to 6200.00mm  
(0.393 to 244.100 inch)  
[mm, inch]  
(2.362 inch)  
2
Pipe material  
12 menus  
PVC  
Carbon steel, Stainless steel, PVC, Copper,  
Castiron, Aluminum, FRP, Ductileiron, PEEK,  
PVDF, Acrylic  
Pipe S.V. : 1000 to 3700m/s  
(3280 to 12140 ft/s)  
Others (Sound velocity :  
[m/s, ft/s])  
3
4
Wall thickness  
Lining material  
0.10 to 100.00mm  
(0.003 to 3.940 inch)  
4.00mm  
(0.157 inch)  
[mm, inch]  
8 menus  
No lining  
No lining,Tar epoxy, Mortar, Rubber,  
Teflon, Pyrex glass, PVC,  
Lining S.V. : 1000 to 3700m/s  
(3280 to 12140 ft/s)  
Others (Sound velocity :  
[m/s, ft/s])  
5
6
Lining thickness  
Kind of Fluid  
0.01 to 100.00mm  
(0.000 to 3.940 inch)  
[mm, inch]  
17 menus  
Water  
Water, Seawater, DIST. water, Ammonia,  
Alcohol, Benzene, Bromide, Ethanol, Glycol,  
Kerosene, Milk, Methanol,Toluol,  
Lube oil,  
Fluid S.V. : 500 to 2500m/s  
(1641 to 8203 ft/s)  
Fuel oil, Petrol,  
Others (Sound velocity :  
(Kinematic viscosity  
[m/s, ft/s])  
Kinematic viscosity :  
[x10-6m2/s, ft2/s])  
0.001 to 999.9999 x 10-6m2/s  
(0.0107 to 10763.9088 x 10-6ft2/s)  
19 menus  
m/s  
(ft/s)  
m/s, L/s, L/min, L/h, L/d, kL/d, ML/d, m3/s,  
m3/min, m3/h, m3/d, km3/d, Mm3/d, BBL/s,  
BBL/min, BBL/h, BBL/d, KBBL/d, MBBL/d,  
(ft/s, ft3/s, ft3/min, ft3/h, ft3/d, kft3/d, Mft3/d,  
gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/d,  
BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d,  
MBBL/d)  
7
Range unit  
8
9
Range type  
4 menus  
Single  
Single, Auto 2, Bi-dir, Bi-dir Auto 2  
[
Full scale or  
Full scale 1  
In terms of flow velocity 0.00 ··· 2.00m/s  
]
]
0.30 to 32.00m/s  
(0.98 to 104.98 ft/s)  
(6.56 ft/s)  
10  
Full scale 2  
In terms of flow velocity 0.00 ··· 4.00m/s  
[
0.30 to 32.00m/s  
(13.12 ft/s)  
(0.98 to 104.98 ft/s)  
11  
12  
13  
14  
15  
16  
Range HYS.  
0.00 to 20.0%  
10.00%  
-20%  
%
%
%
Output limit LO.  
Output limit HI.  
Output burnout  
Burnout timer  
Rate limit  
-20 to 0%  
100 to 120%  
5 menus  
120%  
Hold  
Not use, Hold, Upper, Lower, Zero  
0 to 900sec  
10sec  
sec  
]
0.00 to 5.00m/s  
0.00m/s  
[
(0.00 to 16.40 ft/s)  
in terms of flow velocity  
(0.00 ft/s)  
17  
Rate limit timer  
0 to 900sec  
0.0 to 100.0sec  
7 menus  
0sec  
sec  
sec  
18 Damping  
5.0sec  
19  
20  
1 : Display kind  
Flowrate (m3/s)  
Flow velocity, Flowrate,Total forward,  
Total reverse,  
F :Total pulse, R :Total pulse, Flow rate (%)  
2 : Display kind  
7 menus  
Flow velocity (m/s) Flow velocity, Flowrate,Total forward,  
Total reverse,  
F :Total pulse, R :Total pulse, Flow rate (%)  
21 Low flow cut  
0.00 to 5.00m/s  
0.01m/s  
[
]
(0.00 to 16.40 ft/s)  
in terms of flow velocity  
(0.03 ft/s)  
10  
No.  
22  
Setting item  
Total mode  
Total unit  
Settable range  
Initial value  
Total stop  
Settable value  
3 menus  
8 menus  
Total stop,Total run,Total reset  
23  
mL  
mL, L, m3, km3, Mm3, mBBL, BBL, kBBL,  
ft3, kft3, Mft3, kgal, gal, mBBL, BBL, kBBL,  
ACRF  
24  
25  
26  
27  
28  
29  
30  
31  
32  
Total rate  
0.000 to 999999.999  
0.000 to 9999999999.999  
0.000 to 9999999999.999  
0.000 to 9999999999.999  
0.000 to 9999999999.999  
2 menus  
0.000  
0.000  
0.000  
0.000  
0.000  
Hold  
[
]
]
]
]
]
[
F :Total preset  
F :Total SW  
[
R :Total preset  
R :Total SW  
[
[
Output burnout  
Burnout timer  
Pulse width 1  
Pulse width 2  
Not use, Hold  
0 to 900sec  
10sec  
50ms  
50ms  
sec  
3 menus  
50, 100, 200  
9 menus  
0.5, 1.0, 2.0, 5.0, 10.0, 20.0, 50.0, 100.0,  
200.0  
33  
34  
Flow sw high  
Flow sw low  
In terms of flow velocity  
0.00 to 32.00m/s  
(0.00 to 104.98 ft/s)  
0.00m/s  
4.00m/s  
[
]
]
In terms of flow velocity  
0.00 to 32.00m/s  
[
(0.00 to 104.98 ft/s)  
35  
36  
Flow sw HYS.  
Output DO1  
0 to 20%  
10%  
%
15 menus  
Not use  
Not use, Signal error, F :Total pulse,  
R :Total pulse, F :Total alarm,  
R :Total alarm, F :Total overflow,  
R :Total overflow, Flow SW high,  
Flow SW Low, Full scale2, AO range over,  
Pulse range over, R : Flow direction,  
Device error  
37  
38  
Mode DO1  
2 menus  
Normal  
Not use  
Normal, Reverse  
Output DO2  
15 menus  
Not use, Signal error, F :Total pulse,  
R :Total pulse, F :Total alarm,  
R :Total alarm, F :Total overflow,  
R :Total overflow, Flow SW high,  
Flow SW Low, Full scale2, AO range over,  
Pulse range over, R : Flow direction,  
Device error  
39  
40  
Mode DO2  
2 menus  
Normal  
Not use  
Normal, Reverse  
Output DO3  
15 menus  
Not use, Signal error, F :Total pulse,  
R :Total pulse, F :Total alarm,  
R :Total alarm, F :Total overflow,  
R :Total overflow, Flow SW high,  
Flow SW Low, Full scale2, AO range over,  
Pulse range over, R : Flow direction,  
Device error  
41  
Mode DO3  
2 menus  
Normal  
Normal, Reverse  
11  
FSH, FSW, FLY  
No.  
42  
Setting item  
Settable range  
Initial value  
Metric  
Settable value  
Metric, English  
System unit  
Language  
2 menus  
5 menus  
43  
English  
Japanese, English, German, French,  
spanish  
44  
45  
46  
47  
48  
49  
COM. speed  
3 menus  
3 menus  
2 menus  
2 menus  
38400BPS  
None  
1 bit  
9600BPS, 19200BPS, 38400BPS  
None, Even, Odd  
1 bit, 2bits  
COM. parity  
COM. stop bit  
Serial method  
Station No.  
RS232C  
1
RS232C, RS485  
1 to 31  
31 menus  
2 menus  
Measurement  
mode  
1 Path  
1 Path, 2 Path  
50  
51  
AO Definition  
3 menus  
4 menus  
Line 1  
Average, Line 1, Line 2  
FSW12, FSW21, FSW40, FSW50  
FSW12  
SensorType  
Note1: When total pulse output has been selected for DO1, DO2 or DO3 specify total pulse value and total pulse width so that conditions 1  
and 2 shown below are satisfies.  
Flow span-1*[m3/s]  
total pulse value*[m3]  
Condition 1 :  
Condition 2 :  
1000 [In the case of DO1 and DO2]  
1 [In the case of DO3]  
Flow span-1*[m3/s]  
total pulse value*[m3]  
1000  
2 × total pulse width [ms]  
* In the case of 2 ranges, perform calculations using either flow span-1 or flow span-2, whichever is greater.  
Caution on Safety  
*Before using this product, be sure to read its instruction manual in advance.  
International Sales Div  
Sales Group  
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,  
Shinagawa-ku, Tokyo 141-0032, Japan  
http://www.fujielectric.com  
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425  
http://www.fjielectric.com/products/instruments/  
Information in this catalog is subject to change without notice.  
Printed in Japan  

相关型号:

EDS6-141D

ULTRASONIC FLOWMETER(2-Path System type)
FUJI

EDS6-33B

FCX SERIES DIFFERENTIAL PRESSURE TRANSMITTER
FUJI

EDS6-34F

FCX SERIES REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER
FUJI

EDS6-35D

FCX SERIES FLOW TRANSMITTER
FUJI

EDS6-50I

DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATE WITH CARRIER RINGS
FUJI

EDS6-51E

DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATES WITHOUT CARRIER RINGS
FUJI

EDS6-52G

DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATES WITH FLANGE TAPPINGS
FUJI

EDS6-54E

SINGLE-PART DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATE
FUJI

EDS6-58F

PORTABLE TYPE ULTRASONIC FLOWMETER(PORTAFLOW)
FUJI

EDS6-61H

COMPACT ELECTROMAGNETIC FLOWMETER(COMPACT FLOW)
FUJI

EDS6-64A

COMPACT ELECTROMAGNETIC FLOWMETER(COMPACT FLOW)
FUJI

EDS6-65

COMPACT ELECTROMAGNETIC FLOWMETER(COMPACT FLOW, SEPARATE TYPE)
FUJI