EDS6-132F [FUJI]
HYBRID ULTRASONIC FLOWMETER (PULSE">(Pulse Doppler method Transit Time method); 混合式超声波流量计(脉冲“ \u003e (脉冲多普勒法渡越时间法)型号: | EDS6-132F |
厂家: | FUJI ELECTRIC |
描述: | HYBRID ULTRASONIC FLOWMETER (PULSE">(Pulse Doppler method Transit Time method) |
文件: | 总12页 (文件大小:540K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
HYBRID ULTRASONIC FLOWMETER <Duosonics>
(Pulse Doppler method +TransitTime method)
DATA SHEET
FSH, FSW, FLY
Thisꢀmeterꢀisꢀtheꢀworld’sꢀfirstꢀnon-intrusiveꢀtypeꢀultrasonicꢀ
flowmeterꢀutilizingꢀPulseꢀDopplerꢀmethodꢀalongꢀwithꢀTransitꢀ
Timeꢀmethod.ꢀꢀItꢀenablesꢀmeasurementꢀofꢀvelocityꢀprofileꢀ
directlyꢀresultingꢀinꢀhighꢀaccuracy.ꢀThisꢀmakesꢀitꢀsuitableꢀforꢀ
undevelopedꢀflowꢀandꢀforꢀshortꢀstraightꢀpipes.ꢀPulseꢀDop-
plerꢀmethodꢀrequiresꢀreflectorsꢀinꢀtheꢀliquidꢀandꢀisꢀutilizedꢀonꢀ
opaqueꢀliquidsꢀwhileꢀTransitꢀTimeꢀmethodꢀrequiresꢀultrasoundꢀ
penetrationꢀandꢀisꢀidealꢀforꢀcleanꢀliquids.ꢀTheꢀnewꢀhybridꢀ
technologyꢀutilizesꢀbothꢀmethodsꢀinꢀaꢀcomplementaryꢀfash-
ionꢀthusꢀenablingꢀaꢀwiderꢀrangeꢀofꢀapplicationsꢀthanꢀitꢀisꢀpos-
sibleꢀnow.ꢀInꢀaddition,ꢀthanksꢀtoꢀFuji’sꢀnewꢀstate-of-the-artꢀ
algorithm,ꢀeitherꢀmethodꢀcanꢀbeꢀautomaticallyꢀswitchedꢀtoꢀ
accommodateꢀforꢀvaryingꢀfluidꢀconditionsꢀsuchꢀasꢀconcentra-
tionꢀofꢀparticlesꢀand/orꢀairꢀbubblesꢀandꢀflowꢀvelocity.ꢀ
Flow transmitter
(FSH)
FEATURES
Detector
(FSW)
1. Automatic switchover function between Pulse Doppler
method utilizing ultrasound reflection andTransitTime
method utilizing ultrasound penetration
ꢀ
•ꢀApplicableꢀtoꢀvariousꢀkindsꢀofꢀliquidsꢀwith/withoutꢀairꢀ
bubblesꢀand/orꢀsolidꢀparticles
Application:ꢀ Uniformꢀliquidꢀinꢀwhichꢀultrasonicꢀwavesꢀcanꢀ
propagate.ꢀ
ꢀ
•ꢀApplicableꢀtoꢀliquidꢀflowꢀthatꢀchangesꢀinꢀnatureꢀfrequent-
lyꢀorꢀperiodically
Airꢀbubbleꢀquantity:ꢀ PulseꢀDopplerꢀmethod:ꢀ0.02ꢀtoꢀ
15%ꢀofꢀvolumeꢀatꢀ1ꢀm/s
2. High-accuracy non-intrusive (non-contact) volumetric
flow rate measurement of liquid flow in closed pipes.
ꢀ
ꢀ
Transitꢀtimeꢀmethod:ꢀ0ꢀtoꢀ12%ꢀ
ofꢀvolumeꢀatꢀ1ꢀm/s
•ꢀAccuracyꢀofꢀ0.5%ꢀtoꢀ1%ꢀ(dependingꢀonꢀtheꢀmeasuringꢀ
modeꢀandꢀpipeꢀsize)
•ꢀClamp-onꢀsensor
Fluidꢀtemperature:ꢀꢀ -40ꢀtoꢀ+100ºCꢀ(FSW12),ꢀ-40ꢀtoꢀ
80ºCꢀ(FSW21,ꢀFSW40,FSW50)
ꢀ
3. Direct measurement of velocity profile in case of Pulse
Doppler method
ꢀ
Typeꢀofꢀflow:ꢀ
PulseꢀDopplerꢀmethod:ꢀaxi-
symmetricꢀflowꢀinꢀaꢀfilledꢀpipe.
Transitꢀ timeꢀ method:ꢀ well-
developedꢀturbulentꢀorꢀlaminarꢀ
flowꢀinꢀaꢀfilledꢀpipe.
•ꢀHighꢀaccuracyꢀofꢀ0.5%ꢀtoꢀ1.5%ꢀ(correctionꢀcoefficientꢀ
unnecessary)
•ꢀApplicableꢀtoꢀundevelopedꢀflowꢀ(shortꢀstraightꢀpipe)
•ꢀApplicableꢀtoꢀflowꢀhoveringꢀinꢀtheꢀtransitionalꢀregionꢀ
betweenꢀlaminarꢀflowꢀandꢀturbulentꢀflowꢀ
ꢀ
ꢀ
ꢀ
Applicable flow pipe:
Material:ꢀ
Plasticsꢀ (PVC,ꢀ FRP,ꢀ etc.)ꢀ orꢀ
Metalsꢀ(carbonꢀsteel,ꢀSS,ꢀcop-
per,ꢀaluminum,ꢀetc.)
4. High speed response: 0.2sec (pulse Doppler method)/
0.5sec (transit time method)
5. Real time monitoring of velocity profile by PC in case
of Pulse Doppler method (option)
Pipeꢀsize:ꢀꢀ
40ꢀtoꢀ1000ꢀmm
(insideꢀdiameter)
ꢀ
ꢀ
ꢀ
6. Dual-path option improves performance
Liner:ꢀꢀ
Tarꢀepoxy,ꢀmortar,ꢀetc.ꢀ
Straightꢀpipeꢀlength:ꢀ Typicallyꢀ10Dꢀforꢀupstreamꢀandꢀ
5Dꢀforꢀdownstream.ꢀReferꢀtoꢀ
JEMIS-032ꢀinꢀdetail.
SPECIFICATIONS
Operational specifications
(Note)ꢀJEMIS:ꢀJapanꢀElectricꢀ
MeasuringꢀInstrumentsꢀ
System configuration:
Theꢀsystemꢀisꢀcomposedꢀofꢀone/twoꢀdetec-
torsꢀ(Model:ꢀFSW)ꢀandꢀoneꢀFlowꢀtransmitterꢀ
(Model:ꢀFSH),ꢀrealizingꢀsingle-path/two-pathꢀ
measurement.ꢀ
Hybridꢀmodeꢀorꢀtransitꢀtimeꢀmodeꢀisꢀselect-
able.
Manufactures'ꢀAssocia-
tionsꢀStandard
Hybridꢀmode:ꢀ0ꢀtoꢀ 0.3ꢀ---ꢀ MaximumꢀVeloc-
ityꢀ(dependingꢀonꢀpipeꢀdiameter)ꢀ(Note)ꢀMaxi-
mumꢀmeasurementꢀrangeꢀinꢀHybridꢀmodeꢀ
(seeꢀpageꢀ4)
Velocity:ꢀ
Inꢀcaseꢀofꢀhybridꢀmode,ꢀetherꢀPulseꢀDopplerꢀ
methodꢀorꢀtransitꢀtimeꢀmethodꢀisꢀautomati-
callyꢀselectedꢀdependingꢀonꢀconditionsꢀofꢀ
measuredꢀliquidꢀandꢀmagnitudeꢀofꢀvelocity.
Transitꢀtimeꢀmode:ꢀ0ꢀtoꢀ 0.3ꢀ---ꢀ 32ꢀm/s
Power supply:
100ꢀtoꢀ240ꢀVac+10%/-15%,ꢀ50/60Hzꢀorꢀ20ꢀtoꢀ
30ꢀVdc
EDS6-132f
Date
Apr. 1, 2011
FSH, FSW, FLY
Signal cable:ꢀ Single-pathꢀsystemꢀ:ꢀ
Digital output:+total,ꢀ-total,ꢀalarm,ꢀactingꢀrange,ꢀflowꢀswitchꢀ
orꢀtotalꢀswitchꢀ--ꢀarbitrarilyꢀselectable
Mechanicalꢀrelayꢀcontact:ꢀ
AꢀpairꢀofꢀRFꢀco-axialꢀcablesꢀforꢀultrasoundꢀ
signalsꢀandꢀaꢀthree-coreꢀshieldꢀcableꢀforꢀtem-
peratureꢀsensor,
Two-pathꢀsystem:ꢀTwoꢀpairsꢀofꢀRFꢀco-axialꢀ
cablesꢀforꢀultrasoundꢀsignalsꢀandꢀaꢀthree-coreꢀ
shieldꢀcableꢀforꢀtemperatureꢀsensor,
Maximumꢀcableꢀlength:ꢀ150m
1ꢀpointꢀwithꢀsocketꢀ(replaceable)
Normallyꢀclosed/openꢀselectable
Capacity:240ꢀVac/30ꢀVdc,ꢀ1ꢀAꢀ
Totalꢀpulse:ꢀlessꢀthanꢀ1ꢀp/sꢀ
(Pulseꢀwidth:ꢀ50,ꢀ100ꢀorꢀ200ꢀmsꢀ
selectable)
Temperatureꢀrange:ꢀ80ºC
Environment:ꢀNon-explosiveꢀenvironmentꢀwithoutꢀdirectꢀ
sunlight,ꢀcorrosiveꢀgasꢀandꢀheatꢀradiation
Ambient temperature:
Transistorꢀopenꢀcollector:ꢀ2ꢀpoints
Capacity:ꢀ30ꢀVdc,ꢀ0.1ꢀA
Normallyꢀoff/onꢀselectable
-10ꢀtoꢀ+50ºCꢀforꢀflowꢀtransmitter,ꢀ
-20ꢀtoꢀ+80ºCꢀforꢀdetector
Ambient humidity:
95%RHꢀorꢀlessꢀforꢀflowꢀtransmitter,ꢀ100%RHꢀ
orꢀlessꢀforꢀdetector
Grounding:ꢀ ClassꢀDꢀ(lessꢀthanꢀ100ꢀohm)
Totalꢀpulse:ꢀlessꢀthanꢀ1000ꢀp/sꢀ
(Pulseꢀwidth:ꢀ0.5,ꢀ1,ꢀ2,ꢀ5,ꢀ10,ꢀ20,ꢀ
50,ꢀ100ꢀorꢀ200ꢀmsꢀselectable)
Communication interface:
RS-232Cꢀequivalentꢀ/ꢀRS-485ꢀ(selectable)
Numberꢀofꢀconnectableꢀunits:ꢀoneꢀ(RS-232C)/
upꢀtoꢀ31ꢀ(RS-485)
Baudꢀrate:ꢀ9600/19200/38400ꢀbpsꢀselectable
Parity:ꢀnone/odd/evenꢀselectable
Stopꢀbit:ꢀ1ꢀorꢀ2ꢀbitsꢀselectable
Distance:ꢀupꢀtoꢀ15ꢀmꢀ(RS-232C)/upꢀtoꢀ1kꢀmꢀ
(RS-485)
Arrester:ꢀ
Surgeꢀabsorbersꢀforꢀoutputsꢀandꢀpowerꢀsupplyꢀ
incorporatedꢀasꢀstandard
Performance specifications
Accuracy :
Data:ꢀvelocity,ꢀflowꢀrate,ꢀ+total,ꢀ-total,ꢀstatusꢀ
(standard),ꢀvelocityꢀprofileꢀ(option)
Display device:
Pulse Doppler method :
ꢀꢀPipeꢀsizeꢀ(insideꢀdiameter) Velocity
ꢀꢀandꢀdetector
Accuracy
GraphicꢀLCDꢀ(numberꢀofꢀpixels:ꢀ240x64)ꢀwithꢀ
backꢀlight,ꢀ
ꢀ φ40mmꢀtoꢀφ50mmꢀorꢀless 1.5ꢀm/sꢀto
1.0%ꢀofꢀrate
Display language:
ꢀ (Detector:ꢀFSWS12)
Max.ꢀVelocityꢀ(Note)
Japanese,ꢀEnglish,ꢀFrench,ꢀGermanꢀorꢀSpan-
ishꢀselectable
Velocity/Flow rate display:
0ꢀm/sꢀtoꢀ1.5ꢀm/s
0.015m/s
ꢀ φ50mmꢀtoꢀφ200mmꢀ
ꢀ (Detector:ꢀFSWS12)
1.5ꢀm/sꢀto
0.5%ꢀofꢀrate
Max.ꢀVelocityꢀ(Note)
Displayꢀofꢀvelocityꢀand/orꢀflowꢀrateꢀwithꢀflowꢀ
direction
Data:ꢀupꢀtoꢀ10ꢀdigitsꢀ(decimalꢀpointꢀtoꢀbeꢀ
countedꢀasꢀ1ꢀdigit)
0ꢀm/sꢀtoꢀ1.5ꢀm/s
1ꢀm/sꢀto
0.0075m/s
ꢀ φ100mmꢀtoꢀφ1000mmꢀ
1.0%ꢀofꢀrate
ꢀ (Detector:ꢀꢀFSWS21,40,50) Max.ꢀVelocityꢀ(Note)
Unit:ꢀMetric/Englishꢀsystemꢀselectable
0ꢀm/sꢀtoꢀ1ꢀm/s
0.01m/s
(Note)ꢀ Maximumꢀvelocityꢀisꢀdependꢀonꢀaꢀpipeꢀdiameter.
ꢀ
Metricꢀsystemꢀ
m/sꢀ
Englishꢀsystem
ft/s
ft3/s,ꢀft3/min,ꢀft3/h,ꢀMft3/d,ꢀ
gal/s,ꢀgal/min,ꢀgal/h,ꢀMgal/d,ꢀ
BBL/s,ꢀBBL/min,ꢀBBL/h,ꢀ
BBL/d,ꢀkBBL/d,ꢀMBBL/d
ꢀ
SeeꢀMaximumꢀmeasurementꢀrangeꢀinꢀHybridꢀmodeꢀꢀ(pageꢀ4).
ꢀVelocityꢀ
ꢀFlowꢀrate
Transit time method :
L/s,ꢀL/min,ꢀL/h,ꢀL/d,ꢀkL/h,ꢀ
ML/d,ꢀm3/s,ꢀm3/min,ꢀm3/h,ꢀ
m3/d,ꢀkm3/d,ꢀMm3/d,ꢀ
BBL/s,ꢀBBL/min,ꢀBBL/h,ꢀ
kBBL/d,ꢀMBBL/d
Pipeꢀsizeꢀ(insideꢀdiameter)ꢀ Velocity
Accuracy
1.5%ꢀofꢀrate
0.03m/s
φ40mmꢀtoꢀφ50mmꢀorꢀless
φ50mmꢀtoꢀφ300mmꢀorꢀless
φ300mmꢀtoꢀφ1000mm
2ꢀm/sꢀtoꢀ32ꢀm/s
0ꢀm/sꢀtoꢀ2ꢀm/s
2ꢀm/sꢀtoꢀ32ꢀm/s
0ꢀm/sꢀtoꢀ2ꢀm/s
1ꢀm/sꢀtoꢀ32ꢀm/s
0ꢀm/sꢀtoꢀ1ꢀm/s
1.0%ꢀofꢀrate
0.02m/s
Note:ꢀ˝gal˝ꢀmeansꢀUSꢀgal.
1.0%ꢀofꢀrate
0.01m/s
Total display:ꢀ Displayꢀofꢀforwardꢀorꢀreverseꢀtotal
Data:ꢀupꢀtoꢀ10ꢀdigitsꢀ(decimalꢀpointꢀtoꢀbeꢀ
countedꢀasꢀ1ꢀdigit)
Unit:ꢀ Metric/Englishꢀsystemꢀselectableꢀ
Response time:
PulseꢀDopplerꢀmethod:ꢀ 0.2sec
(dependingꢀonꢀpipeꢀdiameterꢀandꢀ
measuringꢀcondition)
Transitꢀtimeꢀmethod:ꢀ 0.5sec
Power consumption:
20Wꢀorꢀless
Short-term thermal stability:
140ºC,ꢀ30ꢀminꢀ(FSWS12),
100ºC,ꢀ30ꢀminꢀ(FSWS21,ꢀFSWS40,ꢀFSWS50)
ꢀ
Metricꢀsystemꢀ
Englishꢀsystem
ft3,ꢀkft3,ꢀMft3,ꢀgal,ꢀkgal,ꢀ
mL,ꢀL,ꢀm3,ꢀkm3,ꢀMm3,ꢀ
ꢀTotal
mBBL,ꢀBBL,ꢀkBBL,ꢀACRf
mBBL,ꢀBBL,ꢀkBBL
Configuration:
Fullyꢀconfigurableꢀonꢀkeyboardꢀbyꢀmenu-
drivenꢀsoftwareꢀ
Zero adjustment:
Setꢀzero/Clearꢀavailable.ꢀ(transitꢀtimeꢀmethod)
Damping:ꢀ
0ꢀtoꢀ100sꢀ(everyꢀ0.1s)ꢀconfigurableꢀforꢀanalogꢀ
outputꢀandꢀdisplay
Functional specifications
Low flow cut off:ꢀ
0ꢀtoꢀ5ꢀm/sꢀconfigurable
Analog output:ꢀ4ꢀtoꢀ20ꢀmAdcꢀ(1ꢀpoint)
Max.ꢀloadꢀresistance:ꢀ1kꢀohm
2
Alarm:ꢀ
Hardwareꢀfault/processꢀfaultꢀcanꢀbeꢀtiedꢀtoꢀ
digitalꢀoutput
Acoustic coupler:
Siliconꢀcompoundꢀ(RTV)
Burnout:
Analogꢀoutput:ꢀꢀHold/Upperꢀlimit/Lowerꢀlimit/
Zero/Not-usedꢀselectable
Total:ꢀꢀꢀHold/Countꢀselectable
Material:ꢀ
FlowꢀTransmitter:ꢀaluminumꢀalloy
Detector:ꢀPBTꢀforꢀhousing,ꢀaluminumꢀalloyꢀforꢀ
frameꢀandꢀSSꢀforꢀfasteningꢀbelt
Timer:ꢀ0ꢀtoꢀ900sꢀ(everyꢀ1s)ꢀconfigurableꢀꢀ
Bi-directional range:
Forwardꢀandꢀreverseꢀrangesꢀconfigurableꢀin-
Sensor cable(FLY6):
RFꢀcoaxialꢀcableꢀ(doubleꢀshielded)ꢀ
Externalꢀsheath:ꢀBlackꢀflame-resistantꢀvinylꢀ
Externalꢀdiameter:ꢀAboutꢀ7.3ꢀmm
Terminalꢀtreatment:ꢀWater-resistantꢀBNCꢀcon-
nectorꢀ(detectorꢀside),ꢀM3.5ꢀamplifierꢀ
terminalꢀ(FlowꢀTransmitterꢀside)ꢀ
dependently
Hysteresis:ꢀ0ꢀtoꢀ20%ꢀofꢀworkingꢀrangeꢀcon-
figurable
Workingꢀrangeꢀapplicableꢀtoꢀdigitalꢀoutput
Auto-2 ranges:
Weight:ꢀAboutꢀ90ꢀg/mꢀ
Forwardꢀ2ꢀrangesꢀconfigurableꢀindependently
Hysteresis:ꢀ0ꢀtoꢀ20%ꢀofꢀworkingꢀrangeꢀcon-
figurable
Temperature sensor cable(FLY7):
3-coreꢀshieldꢀcable
Externalꢀsheath:ꢀGrayꢀflame-resistantꢀvinylꢀ
Externalꢀdiameter:ꢀAboutꢀ6.9ꢀmm
Terminalꢀtreatment:ꢀRoundꢀwaterproofꢀcon-
nectorꢀ(detectorꢀside),ꢀM3.5ꢀamplifierꢀ
terminalꢀ(FlowꢀTransmitterꢀside)ꢀ
Weight:ꢀAboutꢀ56ꢀg/m
Workingꢀrangeꢀapplicableꢀtoꢀdigitalꢀoutput
Flow switch:ꢀ Lowerꢀandꢀupperꢀswitchingꢀpointsꢀconfigu-
rableꢀindependently
Actingꢀpointꢀapplicableꢀtoꢀdigitalꢀoutput
Total switch:ꢀ +totalꢀswitchingꢀpointꢀconfigurable
Actingꢀpointꢀapplicableꢀtoꢀdigitalꢀoutput
Dimensions:ꢀ FlowꢀTransmitterꢀ:ꢀH240ꢀxꢀW247ꢀxꢀD134ꢀmm
Detector:ꢀH70ꢀxꢀW57ꢀxꢀL360ꢀmmꢀ(FSWS12)
H72ꢀxꢀW57ꢀxꢀL540ꢀmmꢀ(FSWS21)
Physical specifications
Enclosure protection:
FlowꢀTransmitter:ꢀIP67,ꢀ
Detector:ꢀIP67
H90ꢀxꢀW85ꢀxꢀL640ꢀmmꢀ(FSWS40)
H82ꢀxꢀW71ꢀxꢀL258ꢀmmꢀ(FSWS50)
Mounting:ꢀ
FlowꢀTransmitter:ꢀwallꢀmount
Mass:ꢀ
ꢀ
FlowꢀTransmitter:ꢀ5ꢀkg
Detector:ꢀclampedꢀonꢀpipeꢀsurface
Detector:ꢀ1.7ꢀkgꢀ(FSWS12),ꢀ1.9ꢀkgꢀ(FSWS21),ꢀ
5ꢀkgꢀ(FSWS40),ꢀ1.5ꢀkgꢀ(FSWS50)
Conditions on straight pipe
( D : Inside diameter of pipe)
Classification
Upstream side
Downstream side
5D
L
L
10D
90 bend
Detector
L
L
10D
50D
Tee
10D or more
L
5D
L
30D
Diffuser
1.5D
L
5D
L
10D
Reducer
L
30D
L
10D
Various Valve
In case that flow control valve exists on
upstream side.
In case that flow control valve exists on
downstream side.
Stop valve
Check valve
L
50D
Pump
P
(Note)The source : JEMIS-032
3
FSH, FSW, FLY
Measurement principle
Block diagram
<Pulse Doppler method>
(1) Single path system (Z method)
•ꢀ Ultrasoundꢀpulsesꢀareꢀtransmittedꢀintoꢀaꢀliquid,ꢀandꢀ
flowꢀvelocityꢀprofileꢀisꢀfoundꢀandꢀtheꢀflowꢀrateꢀisꢀ
measuredꢀbyꢀusingꢀtheꢀcharacteristicsꢀthatꢀDopplerꢀ
frequencyꢀofꢀtheꢀechoꢀfromꢀreflectorsꢀsuchꢀasꢀairꢀ
bubblesꢀandꢀparticlesꢀinꢀtheꢀliquidꢀchangesꢀaccordingꢀ
toꢀflowꢀvelocity.
Cable
Power
supply
Detector
Flow
4 to 20mA DC
Contact
Transmitter
Sensor 1
(Up to 3 points
are allowed.)
Temperature
sensor cable
Air
Flow
bubbles
Reflection
(2) 2-path system (Z method)
Sensor 2
Flow
Flow
Power
supply
velocity
Profile 2
velocity
Profile 1
Cable
Detector
Flow velocity
4 to 20mA DC
Flow
Transmitter
Piping wall
Center
Piping wall
Contact
(Up to 3 points
are allowed.)
<TransitTime method>
•ꢀ Ultrasoundꢀpulsesꢀareꢀpropagatedꢀslantedꢀbothꢀfromꢀtheꢀ
upstreamꢀandꢀdownstream,ꢀandꢀflowꢀrateꢀisꢀmeasuredꢀbyꢀ
detectingꢀtheꢀtimeꢀdifferenceꢀgeneratedꢀwithꢀtheꢀflow.
Temperature
sensor cable
Sensor 1
Flow
Sensor 2
Transmission
1
Receiving
Sensor 2
Sensor 1
2
Time difference ∆T
Maximum measurement range in hybrid mode
When stainless steel is selected as pipe material, nominal wall thickness is Sch20s, and the fluid is water
<Maximum measurable flow velocity> <Maximum measurable flow rate>
Unit: m3/h
Unit: m/s
FSWS50
Caliber
40A
FSWS12
6.56
FSWS21
FSWS40
FSWS12
33.6
52.7
72.1
86.5
102
FSWS21
FSWS40
FSWS50
50A
65A
80A
6.52
5.31
4.65
4.12
90A
100A
125A
150A
200A
250A
300A
350A
400A
450A
500A
550A
600A
650A
700A
750A
800A
850A
900A
1000A
3.69
3.08
2.63
2.04
7.25
6.08
5.20
4.05
3.30
2.78
2.51
2.20
118
147
179
239
231
289
354
474
604
735
820
951
7.77
6.38
5.41
4.90
4.31
3.80
3.48
908
1168
1428
1598
1858
2118
2358
3.48
3.17
2.91
2.71
2.52
2.35
2.21
2.08
1.97
1.77
2358
2618
2879
3096
3357
3618
3879
4140
4400
4902
4
CODE SYMBOLS
<Flow transmitter>
<Signal cable>
1
2
3
4
5
6
7
8
9
10 11 12
1
2
3
4
5
6
7
8
1
S
Description
Type (4th digit)
1
Description
Kind of cable (4th digit)
Coaxial cable (for ultrasonic sensors)
Three-core cable (for temperature sensor)
F S H
Y
Y Y
F L Y
E
6
7
Standard
Velocity profile output (5th digit)
None
Available
Cable length (5th to 7th digit)
5m
Y
A
0 0 5
0 1 0
0 1 5
0 2 0
0 2 5
0 3 0
0 3 5
0 4 0
0 4 5
0 5 0
0 5 5
0 6 0
0 6 5
0 7 0
0 7 5
0 8 0
0 8 5
0 9 0
0 9 5
1 0 0
1 1 0
1 2 0
1 3 0
1 4 0
1 5 0
10m
15m
20m
25m
30m
35m
40m
45m
50m
55m
60m
65m
70m
75m
80m
85m
90m
95m
100m
110m
120m
130m
140m
150m
Use (6th digit)
Single path or Changeover two-path (Note)
Y
Note: 2 sets of detectors and coaxial cables
(FLY6) needed for two-path system.
Power supply (7th digit)
100 to 240 Vac, 50/60 Hz
20 to 30 Vdc
1
4
Modification No. (8th digit)
Mark 1
1
Case structure (9th digit)
IP67
S
Conduit connection (10th digit)
G1/2 and G3/8 (female screw) with
water-proof connection
Y
For use with explosion-proof detector
(11th digit)
Y
None
Parameter setting, Tag Plate (12th digit)
None
With setting
With setting and Tag Plate
With Tag Plate
Y
A
B
C
Length in m to be designated with 3 digits
Modification No. (8th digit)
1
Mark 1
Loader software for PCs
Equippedꢀasꢀstandard
<Detector>
1
2
3
4
5
6
7
8
9
10 11
•ꢀ WorksꢀonꢀPC/ATꢀcompatibleꢀmachines.
•ꢀ OperationꢀonꢀPC98-seriesꢀmachinesꢀ(NEC)ꢀcannotꢀbeꢀ
guaranteed.
•ꢀ Operationꢀonꢀself-madeꢀPCsꢀorꢀshop-brandꢀPCsꢀcannotꢀ
beꢀguaranteed.
1
Description
F S W S
0
Y
Type (4th digit)
S
Standard
Kind of detector (5th and 6th digit)
Small diameter detector (φ 40 to 200 mm)
Small size detector (φ 100 to 400 mm)
Middle size detector (φ 200 to 500 mm)
Large size detector (φ 500 to 1000mm)
1 2
2 1
4 0
5 0
•ꢀ Majorꢀfunctions:ꢀSetting/changingꢀofꢀvariousꢀparametersꢀ
forꢀtheꢀmainꢀunit
Ifꢀnoꢀflowꢀvelocityꢀprofileꢀoutputꢀisꢀselected,ꢀ
theꢀfollowingꢀfunctionsꢀareꢀnotꢀavailable.
”Detailedꢀsetting”ꢀandꢀ”flowꢀvelocityꢀprofileꢀ
display”ꢀinꢀpulseꢀDopplerꢀmeasurement
”Detailedꢀsetting”ꢀandꢀ”recevedꢀsignalꢀdis-
play”ꢀinꢀTransitꢀtimeꢀmeasurement
Use (7th digit)
Standard (IP67)
0
Modification No. (8th digit)
Mark 1
1
Signal cable (9th digit)
None
Y
Acoustic coupler (10th digit) (Note)
None
Silicone compound
•ꢀ ꢀO/S:ꢀWindows2000/XP
Y
A
•ꢀ Memoryꢀrequirement:ꢀ128MBꢀorꢀmore
•ꢀ Diskꢀunit:ꢀWindows2000/XP-compatibleꢀCD-ROMꢀdrive
•ꢀ Hardꢀdiskꢀdriveꢀcapacity:ꢀFreeꢀspaceꢀofꢀ52MBꢀorꢀmore
N o t e :ꢀ ꢀ P Cꢀ l o a d e rꢀ c o m m u n i c a t i o nꢀ c a b l eꢀ ( t y p eꢀ
ZZP*TK4H6253,ꢀSpecifications:ꢀD-subꢀ9ꢀpinꢀreceptacle,ꢀ
cableꢀlengthꢀ3m)ꢀisꢀseparatelyꢀrequired.
Option (11th digit)
None
Tag Plate
Y
A
(Note) Select silicone compound (A) for acoustic
coupler in ordinary cases. Silicon compound is
supplied in a tube (150g). If one or more
detectors one ordered, silicon compound may
be selected onece every 5 orders or so.
Detector frame installation fixture
Installationꢀfixtureꢀisꢀprovidedꢀtoꢀfacilitateꢀtheꢀpositioningꢀofꢀ
theꢀframeꢀtoꢀtheꢀpiping.
Selectꢀaꢀdesiredꢀtypeꢀfromꢀtheꢀfollowingꢀaccordingꢀtoꢀtheꢀ
detectorꢀtoꢀbeꢀused.
Type
Applicable detector
FSWS12
ZZP TK7M7071C1
ZZP TK7M7071C2
ZZP TK7M7071C3
FSWS21
FSWS40
Note: The installation fixture cannot be used for detector type
FSWS50, which is not provided with a frame.
5
FSH, FSW, FLY
(Unit:mm)
OUTLINE DIAGRAM
<Flow transmitter (type: FSH)>
Mtg. plate
Duosonics
3
134
72
14
233
30 30 30
48 48
24
48
CONNECTION DIAGRAM
Power supply terminals (AC)
1
L
2
N
3
4
1
2
3
4
5
6
7
8
9
B
B
A
+
–
100 to 240V AC
SERIAL
SERIAL
Iout
Power supply terminals (DC)
Cable
(Black)
Cable
(Black)
Cable
(Yellow/
Green)
Communication cable
(option)
No.
RS485
TRX2 (
TRX1 (
SHILD
RS232C
1
+
2
–
3
4
4
5
6
–
)
TXD
RXD
COM
Cap (red)
Cap (yellow)
Cap (black)
+)
To temp sensor
20 to 30V DC
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
HF GND HF GND HF GND HF GND
+
–
+
–
+
–
UP STR DOWN STR UP STR DOWN STR
DO1
DO2
DO3
Relay contact
LINE1
LINE2
Open collector
* Use LINE1 terminals in case of single measuring path.
6
(Unit:mm)
OUTLINE DIAGRAM
<Detector (type: FSWS12, 21)>
Absorber unit
Connector
Sensor unit
(with Temp. sensor)
Cursor
Temp. sensor
Frame
L
(H)
Sensor unit
(without Temp. sensor)
TYPE
PIPE SIZE
ø40~ø200
ø100~ø400
L
H
W
57
57
MASS APPROX
FSWS12
FSWS21
360
540
70
72
1.7
1.9
<Detector (type: FSWS40)>
Absorber unit
Connector
Sensor unit
(with Temp. sensor)
Cursor
Frame
Temp. sensor
640
(90)
Sensor unit
(without Temp. sensor)
7
FSH, FSW, FLY
(Unit:mm)
OUTLINE DIAGRAM
<Detector (type: FSWS50)>
BNC Connector
Temp sensor
Sensor unit
Absorber unit
258
82
8
<Signal cable (type: FLY6)>
<Signal cable (type: FLY7)>
φ15
φ21.5
BNC Connector
Connector
φ11
φ7.3
φ6.9
L:ꢀAccordingꢀtoꢀtheꢀdesignationꢀofꢀtheꢀ5th,ꢀ6th,ꢀandꢀtheꢀ7thꢀ
digitsꢀofꢀtheꢀCodeꢀSymbols.
<Loader cable: ZZP*TK4H6253>
Connector
34
To personal computer
SCOPE OF DELIVERY
•ꢀFlowꢀtransmitterꢀ(Type:ꢀFSH):
ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
Flowꢀtransmitter
CD-ROMꢀ(Instructionꢀmanual,ꢀ
Loaderꢀsoftware)
•ꢀDetectorꢀ(Type:ꢀFSW):ꢀ
ꢀ ꢀ ꢀ
ꢀ ꢀ ꢀ
Sensorꢀunit
Mountingꢀbelt
Siliconꢀcompoundꢀ(option)
φ6.9
•ꢀSignalꢀcableꢀ(Type:ꢀFLY6):ꢀ Cableꢀ(2ꢀwires)
To Flow transmitter
•ꢀSignalꢀcableꢀ(Type:ꢀFLY7):ꢀ Cableꢀforꢀtemperatureꢀsensorꢀ(1)
Terminal cap
(Red)
Terminal cap (Yellow)
Terminal cap (Black)
ITEMS DESIGNATED ORDERING
Black
COM
Red Yellow
TXD RXD
•ꢀFlowꢀtransmitterꢀcodeꢀsymbols
•ꢀDetectorꢀcodeꢀsymbols
•ꢀSignalꢀcableꢀcodeꢀsymbols
RS-232C
9
FSH, FSW, FLY
<Parameter specification table>
No.
1
Setting item
Settable range
Initial value
60.00mm
Settable value
Outer diameter
10.00 to 6200.00mm
(0.393 to 244.100 inch)
[mm, inch]
(2.362 inch)
2
Pipe material
12 menus
PVC
Carbon steel, Stainless steel, PVC, Copper,
Castiron, Aluminum, FRP, Ductileiron, PEEK,
PVDF, Acrylic
Pipe S.V. : 1000 to 3700m/s
(3280 to 12140 ft/s)
Others (Sound velocity :
[m/s, ft/s])
3
4
Wall thickness
Lining material
0.10 to 100.00mm
(0.003 to 3.940 inch)
4.00mm
(0.157 inch)
[mm, inch]
8 menus
No lining
No lining,Tar epoxy, Mortar, Rubber,
Teflon, Pyrex glass, PVC,
Lining S.V. : 1000 to 3700m/s
(3280 to 12140 ft/s)
Others (Sound velocity :
[m/s, ft/s])
5
6
Lining thickness
Kind of Fluid
0.01 to 100.00mm
(0.000 to 3.940 inch)
[mm, inch]
17 menus
Water
Water, Seawater, DIST. water, Ammonia,
Alcohol, Benzene, Bromide, Ethanol, Glycol,
Kerosene, Milk, Methanol,Toluol,
Lube oil,
Fluid S.V. : 500 to 2500m/s
(1641 to 8203 ft/s)
Fuel oil, Petrol,
Others (Sound velocity :
(Kinematic viscosity
[m/s, ft/s])
Kinematic viscosity :
[x10-6m2/s, ft2/s])
0.001 to 999.9999 x 10-6m2/s
(0.0107 to 10763.9088 x 10-6ft2/s)
19 menus
m/s
(ft/s)
m/s, L/s, L/min, L/h, L/d, kL/d, ML/d, m3/s,
m3/min, m3/h, m3/d, km3/d, Mm3/d, BBL/s,
BBL/min, BBL/h, BBL/d, KBBL/d, MBBL/d,
(ft/s, ft3/s, ft3/min, ft3/h, ft3/d, kft3/d, Mft3/d,
gal/s, gal/min, gal/h, gal/d, kgal/d, Mgal/d,
BBL/s, BBL/min, BBL/h, BBL/d, kBBL/d,
MBBL/d)
7
Range unit
8
9
Range type
4 menus
Single
Single, Auto 2, Bi-dir, Bi-dir Auto 2
[
Full scale or
Full scale 1
In terms of flow velocity 0.00 ··· 2.00m/s
]
]
0.30 to 32.00m/s
(0.98 to 104.98 ft/s)
(6.56 ft/s)
10
Full scale 2
In terms of flow velocity 0.00 ··· 4.00m/s
[
0.30 to 32.00m/s
(13.12 ft/s)
(0.98 to 104.98 ft/s)
11
12
13
14
15
16
Range HYS.
0.00 to 20.0%
10.00%
-20%
%
%
%
Output limit LO.
Output limit HI.
Output burnout
Burnout timer
Rate limit
-20 to 0%
100 to 120%
5 menus
120%
Hold
Not use, Hold, Upper, Lower, Zero
0 to 900sec
10sec
sec
]
0.00 to 5.00m/s
0.00m/s
[
(0.00 to 16.40 ft/s)
in terms of flow velocity
(0.00 ft/s)
17
Rate limit timer
0 to 900sec
0.0 to 100.0sec
7 menus
0sec
sec
sec
18 Damping
5.0sec
19
20
1 : Display kind
Flowrate (m3/s)
Flow velocity, Flowrate,Total forward,
Total reverse,
F :Total pulse, R :Total pulse, Flow rate (%)
2 : Display kind
7 menus
Flow velocity (m/s) Flow velocity, Flowrate,Total forward,
Total reverse,
F :Total pulse, R :Total pulse, Flow rate (%)
21 Low flow cut
0.00 to 5.00m/s
0.01m/s
[
]
(0.00 to 16.40 ft/s)
in terms of flow velocity
(0.03 ft/s)
10
No.
22
Setting item
Total mode
Total unit
Settable range
Initial value
Total stop
Settable value
3 menus
8 menus
Total stop,Total run,Total reset
23
mL
mL, L, m3, km3, Mm3, mBBL, BBL, kBBL,
ft3, kft3, Mft3, kgal, gal, mBBL, BBL, kBBL,
ACRF
24
25
26
27
28
29
30
31
32
Total rate
0.000 to 999999.999
0.000 to 9999999999.999
0.000 to 9999999999.999
0.000 to 9999999999.999
0.000 to 9999999999.999
2 menus
0.000
0.000
0.000
0.000
0.000
Hold
[
]
]
]
]
]
[
F :Total preset
F :Total SW
[
R :Total preset
R :Total SW
[
[
Output burnout
Burnout timer
Pulse width 1
Pulse width 2
Not use, Hold
0 to 900sec
10sec
50ms
50ms
sec
3 menus
50, 100, 200
9 menus
0.5, 1.0, 2.0, 5.0, 10.0, 20.0, 50.0, 100.0,
200.0
33
34
Flow sw high
Flow sw low
In terms of flow velocity
0.00 to 32.00m/s
(0.00 to 104.98 ft/s)
0.00m/s
4.00m/s
[
]
]
In terms of flow velocity
0.00 to 32.00m/s
[
(0.00 to 104.98 ft/s)
35
36
Flow sw HYS.
Output DO1
0 to 20%
10%
%
15 menus
Not use
Not use, Signal error, F :Total pulse,
R :Total pulse, F :Total alarm,
R :Total alarm, F :Total overflow,
R :Total overflow, Flow SW high,
Flow SW Low, Full scale2, AO range over,
Pulse range over, R : Flow direction,
Device error
37
38
Mode DO1
2 menus
Normal
Not use
Normal, Reverse
Output DO2
15 menus
Not use, Signal error, F :Total pulse,
R :Total pulse, F :Total alarm,
R :Total alarm, F :Total overflow,
R :Total overflow, Flow SW high,
Flow SW Low, Full scale2, AO range over,
Pulse range over, R : Flow direction,
Device error
39
40
Mode DO2
2 menus
Normal
Not use
Normal, Reverse
Output DO3
15 menus
Not use, Signal error, F :Total pulse,
R :Total pulse, F :Total alarm,
R :Total alarm, F :Total overflow,
R :Total overflow, Flow SW high,
Flow SW Low, Full scale2, AO range over,
Pulse range over, R : Flow direction,
Device error
41
Mode DO3
2 menus
Normal
Normal, Reverse
11
FSH, FSW, FLY
No.
42
Setting item
Settable range
Initial value
Metric
Settable value
Metric, English
System unit
Language
2 menus
5 menus
43
English
Japanese, English, German, French,
spanish
44
45
46
47
48
49
COM. speed
3 menus
3 menus
2 menus
2 menus
38400BPS
None
1 bit
9600BPS, 19200BPS, 38400BPS
None, Even, Odd
1 bit, 2bits
COM. parity
COM. stop bit
Serial method
Station No.
RS232C
1
RS232C, RS485
1 to 31
31 menus
2 menus
Measurement
mode
1 Path
1 Path, 2 Path
50
51
AO Definition
3 menus
4 menus
Line 1
Average, Line 1, Line 2
FSW12, FSW21, FSW40, FSW50
FSW12
SensorType
Note1: When total pulse output has been selected for DO1, DO2 or DO3 specify total pulse value and total pulse width so that conditions 1
and 2 shown below are satisfies.
Flow span-1*[m3/s]
total pulse value*[m3]
Condition 1 :
Condition 2 :
1000 [In the case of DO1 and DO2]
1 [In the case of DO3]
Flow span-1*[m3/s]
total pulse value*[m3]
1000
2 × total pulse width [ms]
* In the case of 2 ranges, perform calculations using either flow span-1 or flow span-2, whichever is greater.
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
International Sales Div
Sales Group
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome,
Shinagawa-ku, Tokyo 141-0032, Japan
http://www.fujielectric.com
Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425
http://www.fjielectric.com/products/instruments/