EDSX5-73 [FUJI]
FCX – AX SERIES PRESSURE TRANSMITTER; FCX - AX系列压力变送器型号: | EDSX5-73 |
厂家: | FUJI ELECTRIC |
描述: | FCX – AX SERIES PRESSURE TRANSMITTER |
文件: | 总8页 (文件大小:162K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
FCX – AX SERIES PRESSURE TRANSMITTER
...
FHG,FKG 3
DATA SHEET
The FCX – AX pressure transmitter accurately measures
gauge pressure and transmits a proportional 4 to 20mA
signal.
The transmitter utilizes a unique micromachined capaci-
tance silicon sensor with state-of-the-art microprocessor
tech- nology to provide exceptional performance and func-
tionality.
FEATURES
1. High accuracy
0.07% accuracy for all calibrated spans is a standard fea-
ture for pressure transmitter covering 6.4 to 50000kPa
{0.064 to 500bar}. Fuji’s micro-capacitance silicon sensor
assures this accuracy for all elevated or suppressed cali-
bration ranges without additional adjustment.
2. Minimum environmental influence
SPECIFICATIONS
The “Advance Floating Cell” design which protects the
pressure sensor against changes in temperature, and
overpressure substantially reduces total measurement
error in actual field applications.
Functional specifications
Type:
Model FHG: 4 to 20mA
3. Replaceable Communication Module
Model FKG: 4 to 20mA with digital signal
Service: Liquid, gas, or vapour
Span, range and overrange limit:
Fuji micro-electronics manufacturing technology offers
replaceable communication module that makes FCX – AX
transmitter very unique in design. In case of change in
communication protocol, all that needs to be done is just
to replace the module and the transmitter gets upgraded
to the new version.
Span limit [kPa] {bar}
Min. Max.
Overrange
limit
Range limit
[kPa] {bar}
Type
[MPa] {bar}
FHG
6.4
FKG
0.64
FHG/FKG
64
4. Fuji/HART bilingual communication module
The communication module is "bilingual" to speak both
Fuji proprietary protocol and HART. Any HART compatible
devices can communicate with FCX – AX series trans-
mitters.
5. Application flexibility
Various options that render the FCX – AX suitable for al-
most any process applications include:
F
F
F
F
F
G
G
G
G
G
01
02
03
04
05
–64 to + 64
1
{10}
1.5
{15}
9
{90}
15
{150}
75
{0.064} {0.0064} {0.64}
50
{–0.64 to +0.64}
–100 to +500
{–1 to + 5}
–100 to +3000
{–1 to + 30}
–100 to +10000
{–1 to + 100 }
–100 to +50000
{–1 to + 500}
5
500
{5}
{0.5}
300
{3}
1000
{10}
5000
{50}
{0.05}
30
{0.3}
100
{1}
500
{5}
3000
{30}
10000
{100}
50000
{500}
{750}
—
Analog indicator at either the electronics side or ter-
minal side
Remark: To minimize environmental influence, span should be greater
than 1/40 of the max. span in most applications.
—Lower range limit (vacuum limit) ;
Silicone fill sensor: See Fig. 1
Fluorinated fill sensor: 66kPa abs (500mmHg abs) at
below 60°C
—Conversion factors to different units;
1 MPa=103 kPa=10bar=10.19716kgf/cm2= 145.0377psi
1kPa=10mbar=101.9716mmH2O =4.01463inH2O
Output signal:
—
—
—
—
Full range of hazardous area approvals
Built-in RFI filter and lightning arrester
4 12 -digits LCD meter
Stainless steel electronics housing
6. Burnout current flexibility (Under Scale: 3.2 to 3.8mA,
Over Scale: 20.8 to 21.6mA)
Burnout signal level is adjustable using Model FXW hand
Held Communicator (HHC) to comply with NAMUR NE43.
(Available for amplifier unit from version 24 and FXW(HHC) version
5.3.)
Model FHG: 4 to 20mA DC 2-wire
Model FKG: 4 to 20mA DC with digital signal super-
imposed on the 4 to 20mA signal.
7. Dry calibration without reference pressure
Thanks to the best combination of unique construction
of mechanical parts (Sensor unit) and high performance
electronics circuit (Electronics unit), reliability of dry
calibration without reference pressure is at equal level
as wet calibration.
EDSX5-73
Date
Mar. 15, 1999
...
FHG, FKG 3
Power supply:
Transmitter operates on 11V to 45V DC
at transmitter terminals.
11V to 32V DC for the units with optional
arrester.
Model FHG: Unless otherwise specified in the order,
the transmitter will be shipped in “Output
Hold” mode.
(Output signal just before failure happens
is maintained.)
Load limitations: see figure below
Model FKG: Selectable from HHC
“Output Hold”:
[Ω]
Output signal is hold as the value just be-
fore failure happens.
“Output Overscale”:
2000
1533Ω
Approx. 21.6mA
1500
(Adjustable within the range 20.8mA to
21.6mA from HHC)
“Output Underscale”:
1000
600Ω
Operating
area
24V
Approx. 3.8mA
(Adjustable within the range 3.2mA to
3.8mA from HHC)
500
250
45V
50
10 16.1
10.5V
[ V ]
4
3.8
20 20.8
3.2
Power voltage
Over scale
Burnout
0
Note: For communication with HHC (Model: FXW), min. of 250 Ω required.
21.6
Probable over range
Normal operating range
Probable under range
Under scale
Burnout
Hazardous locations: (Approval pending)
Type N
Nonincendive
Loop-check output:
Authorities
Flameproof
Intrinsic safety
Model FHG: Transmitter can output a constant signal
of 4mA, 12mA, or 20mA if MODE
SWITCH is set to the loop check mode.
Model FKG: Transmitter can be configured to provide
constant signal 3.8mA through 21.6mA by
HHC.
BASEEFA
Factory
Mutual
Ex ds IIC T5, T6
Class I II III
Div. 1
Groups B thru. G Groups A thru. F
Class I II III
EEx ia IIC T4, T5
Class I II III
Div. 1
Ex N II T5
Class I II III
Div. 2
Groups A thru. G
Class I II III
Div. 2
CSA
Class I II III
Div. 1
Div. 1
Groups C thru. G Groups A thru. G Groups A thru. G
RIIS
SAA
Ex ds IIB+H T4
Ex d II C T5,2T6
IP 66/67
—
—
Temperature limit: Ambient: –40 to +85°C
(–20 to +80°C for LCD indicator)
(–40 to +60°C for arrester option)
(–10 to +60°C for fluorinated oil fill
transmitter)
Ex ia II C T5, T6
IP 66/67
Ex n II C T5, T6
IP 66/67
Zero/span adjustment:
Model FHG: Zero is adjustable from the external ad-
justment screw.
For explosionproof units (flameproof or
intrinsic safety), ambient temperature
must be within the limits specified by
each standard.
Process: – 40 to +100°C for silicone fill
sensor
The adjustment screw can also function to
adjust span when MODE SWITCH (lo-
cated on the electronics unit) is in the span
mode. INHIBIT mode to disable the ad-
justment screw is also available.
Model FKG: Zero and span are adjustable from the
HHC. Zero is also adjustable externally
from the adjustment screw.
–20 to +80°C for fluorinated oil fill sen-
sor
Storage: –40 to +90°C
Damping:
Adjustable electrical damping.
Model FHG: The time constant is adjustable to 0, 0.3,
1.2, 4.8, or 19.2 seconds.
Humidity limit:
Communication: (Model FKG only)
With HHC (Model FXW, consult Data
0 to 100% RH
Model FKG: The time constant is adjustable between 0
to 38.4 seconds. (9 steps)
Zero elevation/suppression:
Sheet No. EDS8-47), following informa-
tion can be remotely displayed or recon-
figured.
Zero can be elevated or suppressed within
the specified range limit of each sensor
model.
Items
Display
Set
Tag No.
Model No.
Serial No.
Engineering unit
Range limit
Measuring range
Damping
Output mode
Burnout direction
Adjustment
Output adjust
Data
Self diagnoses
Printer
External switch lock
v
v
v
v
v
v
v
v
v
v
—
v
v
—
v
v
v
v
—
v
—
v
v
v
v
v
v
Normal/reverse action:
Selectable by moving a jumper pin located
on the electronics unit.
Indication:
Analog indicator or 412 -digit LCD meter, as
specified.
Burnout direction:If self-diagnostic detect transmitter fail-
ure, the analog signal will be driven to ei-
ther “Output Hold”, “Output Overscale”
or “Output Underscale” modes.
—
—
—
v
Transmitter display(*)
v
Note: (*) HHC's version must be more than 5.0 (or
FXW 1– 2), to use this function.
2
Performance specifications
Physical specifications
Accuracy rating: (including linearity, hysteresis, and re-
peatability)
Electrical connections:
G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5
conduit, as specified.
Process connections:
1/4-18 NPT or Rc1/4 as specified.
Process-wetted parts material:
Max span below 10000kPa model:
For spans greater than 1/10 of URL: ±0.07% of span
For spans below 1/10 of URL (Model FKG only):
0.1 × URL
±
0.02+0.05
% of span
(
)
Span
Material
code
(7th digit
in Code
symbols)
Max span 50000kPa model:
Wetted
sensor body
For spans greater than 1/10 of URL: ±0.1% of span
For spans below 1/10 of URL (Model FKG only):
0.1 × URL
Process cover Diaphragm
Vent/drain
±
0.05+0.05
% of span
(
)
V
H
M
T
316 stainless 316L stainless 316 stainless 316 stainless
Span
0.05% of calibrated span
steel(*1)
steel
steel
Hastelloy-C
lining
steel
316 stainless
steel
316 stainless
steel
316 stainless
Linearity:
Stability:
316 stainless Hastelloy-C
steel(*1)
±0.1% of upper range limit (URL) for 24
316 stainless
steel(*1)
316 stainless
steel(*1)
Hastelloy-C
lining
Monel
Monel lining
months
Temperature effect:
Effects per 28°C change between the lim-
Tantalum
Hastelloy-C
Tantalum
lining
Hastelloy-C
lining
steel
Hastelloy-C
B
its of –40°C and +85°C
URL
span
L
U
Monel lining
Tantalum
lining
Monel
Tantalum
Monel lining
Tantalum
lining
Monel
Tantalum
Zero shift: ±(0.1+0.025
)% /28°C
URL
Total effect: ±(0.125+0.025
)%/28°C
span
Note: *(1) SCS14 per JIS G 5121
Remark: Sensor O-rings: Viton and teflon selectable
Availability of above material design depends on
ranges.
Double the effects for material code (7th
digit in Code symbols) "H", "M", "T", "B", "L"
and "U".
Overrange effect: Zero shift; 0.2% of URL for any overrange
to maximum limit
Refer to “Code symbols”.
Non-wetted parts material:
Electronics housing: Low copper die-cast
aluminum alloy (standard), finished
with polyester coating, or 316 stainless
steel (SCS14 per JIS G5121), as speci-
fied.
Bolts and nuts: Cr-Mo alloy (standard), or
304 stainless steel (630 stainless steel
for 50MPa unit).
Fill fluid: Silicone oil (standard) or fluori-
nated oil (Daifloil)
Mounting bracket: Carbon steel with ep-
oxy coating or 304 stainless steel, as
specified
Supply voltage effect:
Less than 0.05% of calibrated span per
10V
RFI effect:
Less than 0.2% of URL for the frequen-
cies of 20 to 1000MHz and field strength
30 V/m when electronics covers on.
(Classification: 2-abc: 0.2% span per
SAMA PMC 33.1)
Step response: Time constant: 0.2s
Dead time: approximately 0.3s
(without electrical damping)
Mounting position effect:
Zero shift, less than 0.1kPa {1m bar} for a
10° tilt in any plane.
No effect on span. This error can be cor-
rected by adjusting Zero.
(Double the effect for fluorinated fill sen-
sors)
Environmental protection:
IEC IP67 and NEMA 4X
Mounting:
On 60.5mm (JIS 50A) pipe using mount-
ing bracket, direct wall mounting, or direct
process mounting.
Mass {weight}:
Transmitter approximately 3.4kg without
options.
Dielectric strength:
500V AC, 50/60Hz 1 min., between circuit
and earth.
Insulation resistance:
More than 100MΩ at 500V DC.
4 sec.
Add; 0.5kg for mounting bracket
0.8kg for indicator option
4.5kg for stainless steel housing
option
Turn-on time:
Internal resistance for external field indicator:
12Ω or less
3
...
FHG, FKG 3
Optional features
ACCESSORIES
Indicator:
A plug-in analog indicator (1.5% accuracy)
Oval flanges:
(Model FFP, refer to Data Sheet No.
EDS6-10)
Converts process connection to 1/2-14
NPT or to Rc1/2; in carbon steel or in 316
stainless steel.
can be housed in the electronics compart-
ment or in the terminal box of the hous-
ing.
An optional 4 21 digits LCD meter is also
available.
Hand-held communicator:
(Model FXW, refer to Data Sheet No.
Arrester:
A built-in arrester protects the electronics
from lightning surges.
Lightning surge immunity:
4KV (1.2 × 50µs)
EDS8-47)
Communication module: (Standard for model FKG)
By adding communication module, re-
mote setting function becomes available
Oxygen service: Special cleaning procedures are followed
throughout the process to maintain all pro-
cess wetted parts oil-free.
for model FHG.
Remark: When the communication module is con-
nected, the operation mode of external
zero/span adjustment screw is limited to
The fill fluid is fluorinated oil.
Chlorine service: The fill fluid is fluorinated oil.
zero adjustment only.
Degreasing:
Process-wetted parts are cleaned, but the
fill fluid is standard silicone oil. Not for use
on oxygen or chlorine measurement.
NACE specification:
Metallic materials for all pressure bound-
The product conforms to the requirements of the
Electromagnetic compatibility Directive 89/336/EEC as
detailed within the technical construction file number
TN510412. The applicable standards used to demonstrate
compliance are :-
ary parts comply with NACE MR-01-75.
ASTM B7M or L7M bolts and 2HM nuts
(Class II) are available.
Vacuum service: Special silicone oil and filling procedure
are applied.
EMI (Emission)
EN50081-1 : 1992
See below figure.
Test item
Frequency range
Basic standard
Applicable Electro-
magnetic Radiation
Disturbance
EN55022
Class B
30-1000MHz
Silicone oil (Code:Y,G,N)
Silicone oil (Code:R)
EMS (Immunity) EN50082-1 : 1992
Test
specification
Basic
standard
Performance
criteria
[kPa abs]
{mbar abs}
No. Test item
101
Electrostatic
discharge
1
8kV (Air)
IEC 801-2:1984
IEC 801-3:1984
B
A
{1010}
Radio-frequency 27-500MHz
electromagnetic 3V/m
field.
Operating
area
2
3
(Unmodulated)
20
{200}
0.5kV, 5/50
(Tr/Th) ns
5kHz Rep.
Fast transients
common mode
IEC 801-4:1988
B
4
{40}
"LVD - The transmitter is not covered by the requirements
of the LVD standard."
2.7
{27}
None-operating
area
–40 –15
60 85 120
Process temperature[°C ]
Fig. 1 Relation between process temperature and
operating pressure
Customer tag:
A stainless steel tag with customer tag
data is wired to the transmitter.
Coating of cell: Cell's surface is finished with epoxy/poly-
urethane double coating. Specify if envi-
ronment is extermely corrosive.
4
CODE SYMBOLS
1
2
3
4
5
6
7
8
9
10 11 12 13
14 15
0
3
Description
Type
FHG
FKG
4 to 20mA, Output type
4 to 20mA with digital signal, Output type
Connections
Process
connection
Oval flange
screwConduit
Conduit
connection
S
T
V
W
X
Rc1/4
7/16-20UNF
7/16-20UNF
M10 (or M12)(*1)
M10 (or M12)(*1)
7/16-20UNF
G 1/2
1/4-18NPT
1/4-18NPT
1/4-18NPT
1/4-18NPT
1/2-14NPT
Pg 13.5
M20×1.5
Pg 13.5
Span and materials
Span limit FHG/FKG
[kPa]{bar}(*2)
Process cover
Diaphragm
Wetted cell body
6.4/0.64…64/64
{0.064/0.0064…0.64/0.64}
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
Hast. C lining
316L stainless steel 316 stainless steel
1V
1H
1M
1T
1B
1L
Hast. C
Monel
Hast. C lining
Monel lining
Tantalum
Hast. C
Monel
Tantalum lining
Hast. C lining
Monel lining
Monel lining
1U
Tantalum lining
Tantalum
Tantalum lining
2V
2H
2M
2T
2B
2L
50/5…500/500
{0.5/0.05…5/5}
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
Hast. C lining
316L stainless steel 316 stainless steel
Hast. C
Monel
Hast. C lining
Monel lining
Tantalum
Hast. C
Monel
Tantalum lining
Hast. C lining
Monel lining
Monel lining
2U
Tantalum lining
Tantalum
Tantalum lining
3V
3H
3M
3T
3B
3L
300/30…3000/3000
{3/0.3…30/30}
316 stainless steel
316 stainless steel
316 stainless steel
316 stainless steel
Hast. C lining
316L stainless steel 316 stainless steel
Hast. C
Monel
Hast. C lining
Monel lining
Tantalum
Hast. C
Monel
Tantalum lining
Hast. C lining
Monel lining
Monel lining
3U
Tantalum lining
Tantalum
Tantalum lining
4V
4H
4M
4T
4B
4L
1000/100…10000/10000
{10/1…100/100}
316stainless steel
316stainless steel
316 stainless steel
316 stainless steel
Hast. C lining
316L stainless steel 316 stainless steel
Hast. C
Monel
Hast. C lining
Monel lining
Tantalum
Hast. C
Monel
Tantalum lining
Hast. C lining
Monel lining
Monel lining
4U
Tantalum lining
Tantalum
Tantalum lining
5V
5000/500…50000/50000
{50/5…500/500}
316 stainless steel
316L stainless steel 316 stainless steel
Notes: * (1) For 50MPa {500bar} units, M12 is provided rather than M10.
(2) 100: 1 turn down is possible for model FKG, but should be used at the span greater than
1/40 of the maximum span for better performance.
5
...
FHG, FKG 3
1
2
3
4
5
6
7
8
9
10 11 12 13
14 15
F H G
F K G
0
3
0
3
Description
Indicator and arrester
Indicator
Arrester
A
B
D
J
E
F
H
K
L
P
Q
S
None
None
None
None
None
Yes
Yes
Yes
Yes
Analog, 0 to 100% linear scale
Analog, custom scale
Analog, double scale
None
Analog, 0 to 100% linear scale
Analog, custom scale
Analog, double scale
Digital, 0 to 100%
Digital, custom scale
Digital, 0 to 100%
Digital, custom scale
None
None (Model FKG only)
Yes
Yes (Model FKG only)
Approvals for hazardous locations (Approval pending)
None (for ordinary locations)
JIS, Flameproof (Conduit seal)
A
B
C
D
E
M
N
H
J
(Available for 4th digit code “S“)
(Available for 4th digit code “S“)
(Available for 4th digit code “T“)
(Available for 4th digit code “T“)
JIS, Flameproof (Cable gland seal)
FM, Flameproof (or explosionproof)
CSA, Flameproof (or explosionproof)
BASEEFA, Flameproof (Conduit seal)
BASEEFA, Flameproof (Cable gland seal) (Conduit connection G 1/2 only)
FM, Intrinsic safety and Nonincendive
CSA, Intrinsic safety and Nonincendive
CENELEC, Intrinsic safety
K
CENELEC, Intrinsic safety and BASEEFA, Type N
SAA Flameproof (Conduit seal)(Available for 4th digit cord (“S,T,W)
SAA Intrinsic safety (Available for 4th digit cord (“S,T,W)
SAA Type–N (non-sparking)(Available for 4th digit cord (“S,T,W)
Side vent/ drain and mounting bracket
P
R
T
Q
Side vent/drain
None
None
None
Yes
Mounting bracket
None
Yes, carbon steel
Yes, stainless steel
None
A
B
C
D
E
F
Specify "A", "B", or
"C" for the 7th digit
code "B", "L", or "U"
}
Yes
Yes
Yes, carbon steel
Yes, stainless steel
Stainless steel parts
Stainless steel tag plate
None
Yes
None
Yes
None
Yes
Stainless steel elec. housing
Coating of cell
None
None
None
None
Yes
Yes
Yes
Yes
Y
B
C
E
M
N
P
None
None
Yes
Yes
None
None
Yes
None
Yes
Q
Yes
Special applications and fill fluid
Treatment
Fill fluid
Y
W
G
A
D
N
None (standard)
None (standard)
Degreasing
Oxygen service
Chlorine service
NACE specification
Silicone oil
Fluorinated oil
Silicone oil
Fluorinated oil (7th digit code "V" only)
Fluorinated oil (7th digit code "H", "T" ,"B", "U")
Silicone oil (Not available for 6th digit code "5", 7th
digit code "T", "U", 15th digit code "A", "B")
Silicone oil for vacuum use
R
Vacuum service
Sensor O-ring
Viton
A
B
Teflon
Bolt/nut
A
B
C
D
E
F
Cr-Mo alloy hexagon socket head cap screw/carbon steel nut
Cr-Mo alloy hexagon bolt/nut
NACE bolt/nut (ASTM A193 B7M/A194 2HM)
NACE bolt/nut (ASTM A320 L7M/A194 2HM)
304 stainless steel/304 stainless steel (*1)
630 stainless steel/304 stainless steel (*1)
Not available for 6th digit code "5"
}
Available for 6th digit code "5"
}
* (1) In case of tropical use, select stainless bolts and nuts.
6
OUTLINE DIAGRAM (Unit:mm)
Vent/drain plug
(When the vent/drain plug attatched on
the upper side of the detector)
Fastener
(In case of 10th
digit code “B,C,M,N“)
Zero/span ADJ. screw
In case of 4th
digit code
“S,V,W,X“
Mtg. Pipe
“A“
Press. conn.
JIS 50A (2")
Up
Down
38
58
“B“
U - Bolt M8
Conduit conn.
30
With field ind.
(option)
224
Vent/drain plug
4 Holes
9 dia.
Cable gland (option)
see note
51
71
(27)
Earth terminal
(both side )
see table1
“C“
Conduit conn.
Detail “A“
DETAIL “B“
Detail “C“
(press conn.)
(Conduit conn.)
ø18.5
H
ø13
ø
15
Oval flange
screw
see table1 1
Side vent
(option)
ø7
2-M8 × 12
G 1/2
D
See table 1
see table 1
27
70
50
Oval flange
screw
Conduit conn.
Press. conn.
H
F
Earth
terminal
4th digit
code
D
120
E
7/16-20UNF
Screw depth13
7/16-20UNF
Screw depth13
M10
Screw depth13
7M10
Screw depth13
7/16-20UNF
Screw depth13
S
T
V
G1/2
1/2
–14NPT
17
Rc1/4
M4
8
16
8
1/4–18NPT
No. 8-32UNC
M4
5
CONNECTION
DIAGRAM
Pg13.5
4.5 1/4–18NPT
–
+
CK+ CK–
16
8
5
W
X
M20 × 1.5
1/4–18NPT
M4
M4
Pg13.5
4.5 1/4–18NPT
Table 1
+
–
S
V
Note1) : Cable gland is supplied in case of flamproof packing type.
ø11 cable is suitable.
T
H
K
H
G
F
0
3
V
W
X
M
T
7
...
FHG, FKG 3
Fastener
(In case of 10th
digit code
Zero/span ADJ. screw
In case of 4th
digit code “S,V,W,X“
“B,C,M,N“)
Mtg.pipe
JIS 50A (2")
U - Bolt M8
Up
Down
38
58
40
“C“
Conduit conn.
4 Holes
9 dia
234
With field ind
(option)
“D“
Cable gland (option)
note see
Conduit conn.
Detail “B“
4th digit code
“T,V,W,X“
Detail “C“
Detail “A“
51
71
(27)
(Conduit conn.)
(Press. conn.“)
4th digit code “S“
Ø16
Earth terminal
(both side)
see table 1
Ø16
+0.2
Ø12
+0.1
Ø 15
1/4-18NPT
Ø4
E
Ø4
View from P
See table 1
“A“ or “B“
press conn.
P
Detail “D“
Ø 13
2-M8 × 12
Oval fgange
screw see table 1
50
36.5
70
120
G 1/2
Oval fgange
screw see table 1
Conduit conn.
4th digit
coode
Earth
terminal
Oval flange
screw
H
E
F
7/16–20UNF
Screw depth 13
M4
S
T
V
G1/2
1/2
17
8
7/16–20UNF
Screw depth 13
CONNECTION
DIAGRAM
16
8
No. 8-32UNC
M4
5
-14NPT
Pg13.5
M20
Pg13.5
S
T
M10
Screw depth 13
–
+
CK+ CK–
4.5
5
B
H
K
G
F
3
L
V
M10
Screw depth 13
16
8
M4
M4
×
1.5
W
X
U
W
X
+
–
7/16–20UNF
Screw depth 13
4.5
Table 1
Note) : Cable gland is supplied in case of flameproof packing type.
ø11 cable is suitable.
Head office
Sales Div.
International Sales Dept.
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan
Phone: 81-42-585-6201, 6202
11-2 Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032 Japan
Phone: 81-3-5435-7111
http://www.fujielectric.co.jp/eng/sg/KEISOKU/welcome.htm
Fax: 81-42-585-6187, 6189
Printed in Japan
Information in this catalog is subject to change without notice.
相关型号: