EDSX5-73 [FUJI]

FCX – AX SERIES PRESSURE TRANSMITTER; FCX - AX系列压力变送器
EDSX5-73
型号: EDSX5-73
厂家: FUJI ELECTRIC    FUJI ELECTRIC
描述:

FCX – AX SERIES PRESSURE TRANSMITTER
FCX - AX系列压力变送器

文件: 总8页 (文件大小:162K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FCX – AX SERIES PRESSURE TRANSMITTER  
...  
FHG,FKG 3  
DATA SHEET  
The FCX – AX pressure transmitter accurately measures  
gauge pressure and transmits a proportional 4 to 20mA  
signal.  
The transmitter utilizes a unique micromachined capaci-  
tance silicon sensor with state-of-the-art microprocessor  
tech- nology to provide exceptional performance and func-  
tionality.  
FEATURES  
1. High accuracy  
0.07% accuracy for all calibrated spans is a standard fea-  
ture for pressure transmitter covering 6.4 to 50000kPa  
{0.064 to 500bar}. Fuji’s micro-capacitance silicon sensor  
assures this accuracy for all elevated or suppressed cali-  
bration ranges without additional adjustment.  
2. Minimum environmental influence  
SPECIFICATIONS  
The “Advance Floating Cell” design which protects the  
pressure sensor against changes in temperature, and  
overpressure substantially reduces total measurement  
error in actual field applications.  
Functional specifications  
Type:  
Model FHG: 4 to 20mA  
3. Replaceable Communication Module  
Model FKG: 4 to 20mA with digital signal  
Service: Liquid, gas, or vapour  
Span, range and overrange limit:  
Fuji micro-electronics manufacturing technology offers  
replaceable communication module that makes FCX – AX  
transmitter very unique in design. In case of change in  
communication protocol, all that needs to be done is just  
to replace the module and the transmitter gets upgraded  
to the new version.  
Span limit [kPa] {bar}  
Min. Max.  
Overrange  
limit  
Range limit  
[kPa] {bar}  
Type  
[MPa] {bar}  
FHG  
6.4  
FKG  
0.64  
FHG/FKG  
64  
4. Fuji/HART bilingual communication module  
The communication module is "bilingual" to speak both  
Fuji proprietary protocol and HART. Any HART compatible  
devices can communicate with FCX – AX series trans-  
mitters.  
5. Application flexibility  
Various options that render the FCX – AX suitable for al-  
most any process applications include:  
F
F
F
F
F
G
G
G
G
G
01  
02  
03  
04  
05  
–64 to + 64  
1
{10}  
1.5  
{15}  
9
{90}  
15  
{150}  
75  
{0.064} {0.0064} {0.64}  
50  
{–0.64 to +0.64}  
–100 to +500  
{–1 to + 5}  
–100 to +3000  
{–1 to + 30}  
–100 to +10000  
{–1 to + 100 }  
–100 to +50000  
{–1 to + 500}  
5
500  
{5}  
{0.5}  
300  
{3}  
1000  
{10}  
5000  
{50}  
{0.05}  
30  
{0.3}  
100  
{1}  
500  
{5}  
3000  
{30}  
10000  
{100}  
50000  
{500}  
{750}  
Analog indicator at either the electronics side or ter-  
minal side  
Remark: To minimize environmental influence, span should be greater  
than 1/40 of the max. span in most applications.  
Lower range limit (vacuum limit) ;  
Silicone fill sensor: See Fig. 1  
Fluorinated fill sensor: 66kPa abs (500mmHg abs) at  
below 60°C  
Conversion factors to different units;  
1 MPa=103 kPa=10bar=10.19716kgf/cm2= 145.0377psi  
1kPa=10mbar=101.9716mmH2O =4.01463inH2O  
Output signal:  
Full range of hazardous area approvals  
Built-in RFI filter and lightning arrester  
4 12 -digits LCD meter  
Stainless steel electronics housing  
6. Burnout current flexibility (Under Scale: 3.2 to 3.8mA,  
Over Scale: 20.8 to 21.6mA)  
Burnout signal level is adjustable using Model FXW hand  
Held Communicator (HHC) to comply with NAMUR NE43.  
(Available for amplifier unit from version 24 and FXW(HHC) version  
5.3.)  
Model FHG: 4 to 20mA DC 2-wire  
Model FKG: 4 to 20mA DC with digital signal super-  
imposed on the 4 to 20mA signal.  
7. Dry calibration without reference pressure  
Thanks to the best combination of unique construction  
of mechanical parts (Sensor unit) and high performance  
electronics circuit (Electronics unit), reliability of dry  
calibration without reference pressure is at equal level  
as wet calibration.  
EDSX5-73  
Date  
Mar. 15, 1999  
...  
FHG, FKG 3  
Power supply:  
Transmitter operates on 11V to 45V DC  
at transmitter terminals.  
11V to 32V DC for the units with optional  
arrester.  
Model FHG: Unless otherwise specified in the order,  
the transmitter will be shipped in “Output  
Hold” mode.  
(Output signal just before failure happens  
is maintained.)  
Load limitations: see figure below  
Model FKG: Selectable from HHC  
“Output Hold”:  
[]  
Output signal is hold as the value just be-  
fore failure happens.  
“Output Overscale”:  
2000  
1533Ω  
Approx. 21.6mA  
1500  
(Adjustable within the range 20.8mA to  
21.6mA from HHC)  
“Output Underscale”:  
1000  
600Ω  
Operating  
area  
24V  
Approx. 3.8mA  
(Adjustable within the range 3.2mA to  
3.8mA from HHC)  
500  
250  
45V  
50  
10 16.1  
10.5V  
[ V ]  
4
3.8  
20 20.8  
3.2  
Power voltage  
Over scale  
Burnout  
0
Note: For communication with HHC (Model: FXW), min. of 250 required.  
21.6  
Probable over range  
Normal operating range  
Probable under range  
Under scale  
Burnout  
Hazardous locations: (Approval pending)  
Type N  
Nonincendive  
Loop-check output:  
Authorities  
Flameproof  
Intrinsic safety  
Model FHG: Transmitter can output a constant signal  
of 4mA, 12mA, or 20mA if MODE  
SWITCH is set to the loop check mode.  
Model FKG: Transmitter can be configured to provide  
constant signal 3.8mA through 21.6mA by  
HHC.  
BASEEFA  
Factory  
Mutual  
Ex ds IIC T5, T6  
Class I II III  
Div. 1  
Groups B thru. G Groups A thru. F  
Class I II III  
EEx ia IIC T4, T5  
Class I II III  
Div. 1  
Ex N II T5  
Class I II III  
Div. 2  
Groups A thru. G  
Class I II III  
Div. 2  
CSA  
Class I II III  
Div. 1  
Div. 1  
Groups C thru. G Groups A thru. G Groups A thru. G  
RIIS  
SAA  
Ex ds IIB+H T4  
Ex d II C T5,2T6  
IP 66/67  
Temperature limit: Ambient: 40 to +85°C  
(–20 to +80°C for LCD indicator)  
(40 to +60°C for arrester option)  
(–10 to +60°C for fluorinated oil fill  
transmitter)  
Ex ia II C T5, T6  
IP 66/67  
Ex n II C T5, T6  
IP 66/67  
Zero/span adjustment:  
Model FHG: Zero is adjustable from the external ad-  
justment screw.  
For explosionproof units (flameproof or  
intrinsic safety), ambient temperature  
must be within the limits specified by  
each standard.  
Process: – 40 to +100°C for silicone fill  
sensor  
The adjustment screw can also function to  
adjust span when MODE SWITCH (lo-  
cated on the electronics unit) is in the span  
mode. INHIBIT mode to disable the ad-  
justment screw is also available.  
Model FKG: Zero and span are adjustable from the  
HHC. Zero is also adjustable externally  
from the adjustment screw.  
–20 to +80°C for fluorinated oil fill sen-  
sor  
Storage: –40 to +90°C  
Damping:  
Adjustable electrical damping.  
Model FHG: The time constant is adjustable to 0, 0.3,  
1.2, 4.8, or 19.2 seconds.  
Humidity limit:  
Communication: (Model FKG only)  
With HHC (Model FXW, consult Data  
0 to 100% RH  
Model FKG: The time constant is adjustable between 0  
to 38.4 seconds. (9 steps)  
Zero elevation/suppression:  
Sheet No. EDS8-47), following informa-  
tion can be remotely displayed or recon-  
figured.  
Zero can be elevated or suppressed within  
the specified range limit of each sensor  
model.  
Items  
Display  
Set  
Tag No.  
Model No.  
Serial No.  
Engineering unit  
Range limit  
Measuring range  
Damping  
Output mode  
Burnout direction  
Adjustment  
Output adjust  
Data  
Self diagnoses  
Printer  
External switch lock  
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
v
Normal/reverse action:  
Selectable by moving a jumper pin located  
on the electronics unit.  
Indication:  
Analog indicator or 412 -digit LCD meter, as  
specified.  
Burnout direction:If self-diagnostic detect transmitter fail-  
ure, the analog signal will be driven to ei-  
ther “Output Hold”, “Output Overscale”  
or “Output Underscale” modes.  
v
Transmitter display(*)  
v
Note: (*) HHC's version must be more than 5.0 (or  
FXW 1 2), to use this function.  
2
Performance specifications  
Physical specifications  
Accuracy rating: (including linearity, hysteresis, and re-  
peatability)  
Electrical connections:  
G1/2, 1/2-14 NPT, Pg13.5, or M20 × 1.5  
conduit, as specified.  
Process connections:  
1/4-18 NPT or Rc1/4 as specified.  
Process-wetted parts material:  
Max span below 10000kPa model:  
For spans greater than 1/10 of URL: ±0.07% of span  
For spans below 1/10 of URL (Model FKG only):  
0.1 × URL  
±
0.02+0.05  
% of span  
(
)
Span  
Material  
code  
(7th digit  
in Code  
symbols)  
Max span 50000kPa model:  
Wetted  
sensor body  
For spans greater than 1/10 of URL: ±0.1% of span  
For spans below 1/10 of URL (Model FKG only):  
0.1 × URL  
Process cover Diaphragm  
Vent/drain  
±
0.05+0.05  
% of span  
(
)
V
H
M
T
316 stainless 316L stainless 316 stainless 316 stainless  
Span  
0.05% of calibrated span  
steel(*1)  
steel  
steel  
Hastelloy-C  
lining  
steel  
316 stainless  
steel  
316 stainless  
steel  
316 stainless  
Linearity:  
Stability:  
316 stainless Hastelloy-C  
steel(*1)  
±0.1% of upper range limit (URL) for 24  
316 stainless  
steel(*1)  
316 stainless  
steel(*1)  
Hastelloy-C  
lining  
Monel  
Monel lining  
months  
Temperature effect:  
Effects per 28°C change between the lim-  
Tantalum  
Hastelloy-C  
Tantalum  
lining  
Hastelloy-C  
lining  
steel  
Hastelloy-C  
B
its of –40°C and +85°C  
URL  
span  
L
U
Monel lining  
Tantalum  
lining  
Monel  
Tantalum  
Monel lining  
Tantalum  
lining  
Monel  
Tantalum  
Zero shift: ±(0.1+0.025  
)% /28°C  
URL  
Total effect: ±(0.125+0.025  
)%/28°C  
span  
Note: *(1) SCS14 per JIS G 5121  
Remark: Sensor O-rings: Viton and teflon selectable  
Availability of above material design depends on  
ranges.  
Double the effects for material code (7th  
digit in Code symbols) "H", "M", "T", "B", "L"  
and "U".  
Overrange effect: Zero shift; 0.2% of URL for any overrange  
to maximum limit  
Refer to “Code symbols”.  
Non-wetted parts material:  
Electronics housing: Low copper die-cast  
aluminum alloy (standard), finished  
with polyester coating, or 316 stainless  
steel (SCS14 per JIS G5121), as speci-  
fied.  
Bolts and nuts: Cr-Mo alloy (standard), or  
304 stainless steel (630 stainless steel  
for 50MPa unit).  
Fill fluid: Silicone oil (standard) or fluori-  
nated oil (Daifloil)  
Mounting bracket: Carbon steel with ep-  
oxy coating or 304 stainless steel, as  
specified  
Supply voltage effect:  
Less than 0.05% of calibrated span per  
10V  
RFI effect:  
Less than 0.2% of URL for the frequen-  
cies of 20 to 1000MHz and field strength  
30 V/m when electronics covers on.  
(Classification: 2-abc: 0.2% span per  
SAMA PMC 33.1)  
Step response: Time constant: 0.2s  
Dead time: approximately 0.3s  
(without electrical damping)  
Mounting position effect:  
Zero shift, less than 0.1kPa {1m bar} for a  
10° tilt in any plane.  
No effect on span. This error can be cor-  
rected by adjusting Zero.  
(Double the effect for fluorinated fill sen-  
sors)  
Environmental protection:  
IEC IP67 and NEMA 4X  
Mounting:  
On 60.5mm (JIS 50A) pipe using mount-  
ing bracket, direct wall mounting, or direct  
process mounting.  
Mass {weight}:  
Transmitter approximately 3.4kg without  
options.  
Dielectric strength:  
500V AC, 50/60Hz 1 min., between circuit  
and earth.  
Insulation resistance:  
More than 100Mat 500V DC.  
4 sec.  
Add; 0.5kg for mounting bracket  
0.8kg for indicator option  
4.5kg for stainless steel housing  
option  
Turn-on time:  
Internal resistance for external field indicator:  
12or less  
3
...  
FHG, FKG 3  
Optional features  
ACCESSORIES  
Indicator:  
A plug-in analog indicator (1.5% accuracy)  
Oval flanges:  
(Model FFP, refer to Data Sheet No.  
EDS6-10)  
Converts process connection to 1/2-14  
NPT or to Rc1/2; in carbon steel or in 316  
stainless steel.  
can be housed in the electronics compart-  
ment or in the terminal box of the hous-  
ing.  
An optional 4 21 digits LCD meter is also  
available.  
Hand-held communicator:  
(Model FXW, refer to Data Sheet No.  
Arrester:  
A built-in arrester protects the electronics  
from lightning surges.  
Lightning surge immunity:  
4KV (1.2 × 50µs)  
EDS8-47)  
Communication module: (Standard for model FKG)  
By adding communication module, re-  
mote setting function becomes available  
Oxygen service: Special cleaning procedures are followed  
throughout the process to maintain all pro-  
cess wetted parts oil-free.  
for model FHG.  
Remark: When the communication module is con-  
nected, the operation mode of external  
zero/span adjustment screw is limited to  
The fill fluid is fluorinated oil.  
Chlorine service: The fill fluid is fluorinated oil.  
zero adjustment only.  
Degreasing:  
Process-wetted parts are cleaned, but the  
fill fluid is standard silicone oil. Not for use  
on oxygen or chlorine measurement.  
NACE specification:  
Metallic materials for all pressure bound-  
The product conforms to the requirements of the  
Electromagnetic compatibility Directive 89/336/EEC as  
detailed within the technical construction file number  
TN510412. The applicable standards used to demonstrate  
compliance are :-  
ary parts comply with NACE MR-01-75.  
ASTM B7M or L7M bolts and 2HM nuts  
(Class II) are available.  
Vacuum service: Special silicone oil and filling procedure  
are applied.  
EMI (Emission)  
EN50081-1 : 1992  
See below figure.  
Test item  
Frequency range  
Basic standard  
Applicable Electro-  
magnetic Radiation  
Disturbance  
EN55022  
Class B  
30-1000MHz  
Silicone oil (Code:Y,G,N)  
Silicone oil (Code:R)  
EMS (Immunity) EN50082-1 : 1992  
Test  
specification  
Basic  
standard  
Performance  
criteria  
[kPa abs]  
{mbar abs}  
No. Test item  
101  
Electrostatic  
discharge  
1
8kV (Air)  
IEC 801-2:1984  
IEC 801-3:1984  
B
A
{1010}  
Radio-frequency 27-500MHz  
electromagnetic 3V/m  
field.  
Operating  
area  
2
3
(Unmodulated)  
20  
{200}  
0.5kV, 5/50  
(Tr/Th) ns  
5kHz Rep.  
Fast transients  
common mode  
IEC 801-4:1988  
B
4
{40}  
"LVD - The transmitter is not covered by the requirements  
of the LVD standard."  
2.7  
{27}  
None-operating  
area  
–40 –15  
60 85 120  
Process temperature[°C ]  
Fig. 1 Relation between process temperature and  
operating pressure  
Customer tag:  
A stainless steel tag with customer tag  
data is wired to the transmitter.  
Coating of cell: Cell's surface is finished with epoxy/poly-  
urethane double coating. Specify if envi-  
ronment is extermely corrosive.  
4
CODE SYMBOLS  
1
2
3
4
5
6
7
8
9
10 11 12 13  
14 15  
0
3
Description  
Type  
FHG  
FKG  
4 to 20mA, Output type  
4 to 20mA with digital signal, Output type  
Connections  
Process  
connection  
Oval flange  
screwConduit  
Conduit  
connection  
S
T
V
W
X
Rc1/4  
7/16-20UNF  
7/16-20UNF  
M10 (or M12)(*1)  
M10 (or M12)(*1)  
7/16-20UNF  
G 1/2  
1/4-18NPT  
1/4-18NPT  
1/4-18NPT  
1/4-18NPT  
1/2-14NPT  
Pg 13.5  
M20×1.5  
Pg 13.5  
Span and materials  
Span limit FHG/FKG  
[kPa]{bar}(*2)  
Process cover  
Diaphragm  
Wetted cell body  
6.4/0.64…64/64  
{0.064/0.0064…0.64/0.64}  
316 stainless steel  
316 stainless steel  
316 stainless steel  
316 stainless steel  
Hast. C lining  
316L stainless steel 316 stainless steel  
1V  
1H  
1M  
1T  
1B  
1L  
Hast. C  
Monel  
Hast. C lining  
Monel lining  
Tantalum  
Hast. C  
Monel  
Tantalum lining  
Hast. C lining  
Monel lining  
Monel lining  
1U  
Tantalum lining  
Tantalum  
Tantalum lining  
2V  
2H  
2M  
2T  
2B  
2L  
50/5…500/500  
{0.5/0.05…5/5}  
316 stainless steel  
316 stainless steel  
316 stainless steel  
316 stainless steel  
Hast. C lining  
316L stainless steel 316 stainless steel  
Hast. C  
Monel  
Hast. C lining  
Monel lining  
Tantalum  
Hast. C  
Monel  
Tantalum lining  
Hast. C lining  
Monel lining  
Monel lining  
2U  
Tantalum lining  
Tantalum  
Tantalum lining  
3V  
3H  
3M  
3T  
3B  
3L  
300/30…3000/3000  
{3/0.3…30/30}  
316 stainless steel  
316 stainless steel  
316 stainless steel  
316 stainless steel  
Hast. C lining  
316L stainless steel 316 stainless steel  
Hast. C  
Monel  
Hast. C lining  
Monel lining  
Tantalum  
Hast. C  
Monel  
Tantalum lining  
Hast. C lining  
Monel lining  
Monel lining  
3U  
Tantalum lining  
Tantalum  
Tantalum lining  
4V  
4H  
4M  
4T  
4B  
4L  
1000/100…10000/10000  
{10/1…100/100}  
316stainless steel  
316stainless steel  
316 stainless steel  
316 stainless steel  
Hast. C lining  
316L stainless steel 316 stainless steel  
Hast. C  
Monel  
Hast. C lining  
Monel lining  
Tantalum  
Hast. C  
Monel  
Tantalum lining  
Hast. C lining  
Monel lining  
Monel lining  
4U  
Tantalum lining  
Tantalum  
Tantalum lining  
5V  
5000/500…50000/50000  
{50/5…500/500}  
316 stainless steel  
316L stainless steel 316 stainless steel  
Notes: * (1) For 50MPa {500bar} units, M12 is provided rather than M10.  
(2) 100: 1 turn down is possible for model FKG, but should be used at the span greater than  
1/40 of the maximum span for better performance.  
5
...  
FHG, FKG 3  
1
2
3
4
5
6
7
8
9
10 11 12 13  
14 15  
F H G  
F K G  
0
3
0
3
Description  
Indicator and arrester  
Indicator  
Arrester  
A
B
D
J
E
F
H
K
L
P
Q
S
None  
None  
None  
None  
None  
Yes  
Yes  
Yes  
Yes  
Analog, 0 to 100% linear scale  
Analog, custom scale  
Analog, double scale  
None  
Analog, 0 to 100% linear scale  
Analog, custom scale  
Analog, double scale  
Digital, 0 to 100%  
Digital, custom scale  
Digital, 0 to 100%  
Digital, custom scale  
None  
None (Model FKG only)  
Yes  
Yes (Model FKG only)  
Approvals for hazardous locations (Approval pending)  
None (for ordinary locations)  
JIS, Flameproof (Conduit seal)  
A
B
C
D
E
M
N
H
J
(Available for 4th digit code “S“)  
(Available for 4th digit code “S“)  
(Available for 4th digit code “T“)  
(Available for 4th digit code “T“)  
JIS, Flameproof (Cable gland seal)  
FM, Flameproof (or explosionproof)  
CSA, Flameproof (or explosionproof)  
BASEEFA, Flameproof (Conduit seal)  
BASEEFA, Flameproof (Cable gland seal) (Conduit connection G 1/2 only)  
FM, Intrinsic safety and Nonincendive  
CSA, Intrinsic safety and Nonincendive  
CENELEC, Intrinsic safety  
K
CENELEC, Intrinsic safety and BASEEFA, Type N  
SAA Flameproof (Conduit seal)(Available for 4th digit cord (“S,T,W)  
SAA Intrinsic safety (Available for 4th digit cord (“S,T,W)  
SAA Type–N (non-sparking)(Available for 4th digit cord (“S,T,W)  
Side vent/ drain and mounting bracket  
P
R
T
Q
Side vent/drain  
None  
None  
None  
Yes  
Mounting bracket  
None  
Yes, carbon steel  
Yes, stainless steel  
None  
A
B
C
D
E
F
Specify "A", "B", or  
"C" for the 7th digit  
code "B", "L", or "U"  
}
Yes  
Yes  
Yes, carbon steel  
Yes, stainless steel  
Stainless steel parts  
Stainless steel tag plate  
None  
Yes  
None  
Yes  
None  
Yes  
Stainless steel elec. housing  
Coating of cell  
None  
None  
None  
None  
Yes  
Yes  
Yes  
Yes  
Y
B
C
E
M
N
P
None  
None  
Yes  
Yes  
None  
None  
Yes  
None  
Yes  
Q
Yes  
Special applications and fill fluid  
Treatment  
Fill fluid  
Y
W
G
A
D
N
None (standard)  
None (standard)  
Degreasing  
Oxygen service  
Chlorine service  
NACE specification  
Silicone oil  
Fluorinated oil  
Silicone oil  
Fluorinated oil (7th digit code "V" only)  
Fluorinated oil (7th digit code "H", "T" ,"B", "U")  
Silicone oil (Not available for 6th digit code "5", 7th  
digit code "T", "U", 15th digit code "A", "B")  
Silicone oil for vacuum use  
R
Vacuum service  
Sensor O-ring  
Viton  
A
B
Teflon  
Bolt/nut  
A
B
C
D
E
F
Cr-Mo alloy hexagon socket head cap screw/carbon steel nut  
Cr-Mo alloy hexagon bolt/nut  
NACE bolt/nut (ASTM A193 B7M/A194 2HM)  
NACE bolt/nut (ASTM A320 L7M/A194 2HM)  
304 stainless steel/304 stainless steel (*1)  
630 stainless steel/304 stainless steel (*1)  
Not available for 6th digit code "5"  
}
Available for 6th digit code "5"  
}
* (1) In case of tropical use, select stainless bolts and nuts.  
6
OUTLINE DIAGRAM (Unit:mm)  
Vent/drain plug  
(When the vent/drain plug attatched on  
the upper side of the detector)  
Fastener  
(In case of 10th  
digit code “B,C,M,N“)  
Zero/span ADJ. screw  
In case of 4th  
digit code  
“S,V,W,X“  
Mtg. Pipe  
“A“  
Press. conn.  
JIS 50A (2")  
Up  
Down  
38  
58  
“B“  
U - Bolt M8  
Conduit conn.  
30  
With field ind.  
(option)  
224  
Vent/drain plug  
4 Holes  
9 dia.  
Cable gland (option)  
see note  
51  
71  
(27)  
Earth terminal  
(both side )  
see table1  
“C“  
Conduit conn.  
Detail “A“  
DETAIL “B“  
Detail “C“  
(press conn.)  
(Conduit conn.)  
ø18.5  
H
ø13  
ø
15  
Oval flange  
screw  
see table1 1  
Side vent  
(option)  
ø7  
2-M8 × 12  
G 1/2  
D
See table 1  
see table 1  
27  
70  
50  
Oval flange  
screw  
Conduit conn.  
Press. conn.  
H
F
Earth  
terminal  
4th digit  
code  
D
120  
E
7/16-20UNF  
Screw depth13  
7/16-20UNF  
Screw depth13  
M10  
Screw depth13  
7M10  
Screw depth13  
7/16-20UNF  
Screw depth13  
S
T
V
G1/2  
1/2  
–14NPT  
17  
Rc1/4  
M4  
8
16  
8
1/4–18NPT  
No. 8-32UNC  
M4  
5
CONNECTION  
DIAGRAM  
Pg13.5  
4.5 1/4–18NPT  
+
CK+ CK–  
16  
8
5
W
X
M20 × 1.5  
1/4–18NPT  
M4  
M4  
Pg13.5  
4.5 1/4–18NPT  
Table 1  
+
S
V
Note1) : Cable gland is supplied in case of flamproof packing type.  
ø11 cable is suitable.  
T
H
K
H
G
F
0
3
V
W
X
M
T
7
...  
FHG, FKG 3  
Fastener  
(In case of 10th  
digit code  
Zero/span ADJ. screw  
In case of 4th  
digit code “S,V,W,X“  
“B,C,M,N“)  
Mtg.pipe  
JIS 50A (2")  
U - Bolt M8  
Up  
Down  
38  
58  
40  
“C“  
Conduit conn.  
4 Holes  
9 dia  
234  
With field ind  
(option)  
“D“  
Cable gland (option)  
note see  
Conduit conn.  
Detail “B“  
4th digit code  
“T,V,W,X“  
Detail “C“  
Detail “A“  
51  
71  
(27)  
(Conduit conn.)  
(Press. conn.“)  
4th digit code “S“  
Ø16  
Earth terminal  
(both side)  
see table 1  
Ø16  
+0.2  
Ø12  
+0.1  
Ø 15  
1/4-18NPT  
Ø4  
E
Ø4  
View from P  
See table 1  
“A“ or “B“  
press conn.  
P
Detail “D“  
Ø 13  
2-M8 × 12  
Oval fgange  
screw see table 1  
50  
36.5  
70  
120  
G 1/2  
Oval fgange  
screw see table 1  
Conduit conn.  
4th digit  
coode  
Earth  
terminal  
Oval flange  
screw  
H
E
F
7/16–20UNF  
Screw depth 13  
M4  
S
T
V
G1/2  
1/2  
17  
8
7/16–20UNF  
Screw depth 13  
CONNECTION  
DIAGRAM  
16  
8
No. 8-32UNC  
M4  
5
-14NPT  
Pg13.5  
M20  
Pg13.5  
S
T
M10  
Screw depth 13  
+
CK+ CK–  
4.5  
5
B
H
K
G
F
3
L
V
M10  
Screw depth 13  
16  
8
M4  
M4  
×
1.5  
W
X
U
W
X
+
7/16–20UNF  
Screw depth 13  
4.5  
Table 1  
Note) : Cable gland is supplied in case of flameproof packing type.  
ø11 cable is suitable.  
Head office  
Sales Div.  
International Sales Dept.  
No.1, Fuji-machi, Hino-city, Tokyo, 191-8502 Japan  
Phone: 81-42-585-6201, 6202  
11-2 Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032 Japan  
Phone: 81-3-5435-7111  
http://www.fujielectric.co.jp/eng/sg/KEISOKU/welcome.htm  
Fax: 81-42-585-6187, 6189  
Printed in Japan  
Information in this catalog is subject to change without notice.  

相关型号:

EDSX5-74

FCX – AX SERIES SMALL FLANGE REMOTE SEAL TYPE PRESSURE TRANSMITTER
FUJI

EDSX5-75

FCX – C SERIES ABSOLUTE PRESSURE TRANSMITTER
FUJI

EDSX5-76A

FCX – C SERIES PRESSURE TRANSMITTER
FUJI

EDSX5-77

FCX –AX SERIES PRESSURE TRANSMITTER Hydroseal® Diaphragm Version
FUJI

EDSX5-79J

ABSOLUTE PRESSURE TRANSMITTER
FUJI

EDSX5-80K

PRESSURE TRANSMITTER
FUJI

EDSX5-82K

SMALL FLANGE REMOTE SEAL TYPE PRESSURE TRANSMITTER
FUJI

EDSX5-83J

REMOTE SEAL TYPE PRESSURE TRANSMITTER
FUJI

EDSX5-85D

ELECTRONIC TRANSMITTER with FIELDBUS
FUJI

EDSX5-86D

PRESSURE TRANSMITTER
FUJI

EDSX5-87A

FCX – C2 PRESSURE TRANSMITTER
FUJI

EDSX5-91H

ABSOLUTE PRESSURE TRANSMITTER
FUJI