M46-OL [GAMEWELL-FCI]

Conventional Fire Alarm Pull Stations; 传统的火灾报警拉站
M46-OL
型号: M46-OL
厂家: GAMEWELL-FCI BY HONEYWELL    GAMEWELL-FCI BY HONEYWELL
描述:

Conventional Fire Alarm Pull Stations
传统的火灾报警拉站

文件: 总2页 (文件大小:220K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
M46-L Series  
Conventional Fire Alarm Pull Stations  
Description  
The Gamewell-FCI M46-L Series is a cost-effective, fea-  
ture-packed series of non-coded manual fire alarm pull sta-  
tions. It was designed to meet multiple applications used  
by the installer and end-user. The M46-L Series features a  
variety of models including single- and dual-action  
versions.  
The M46-L Series provides conventional Fire Alarm Con-  
trol Panels (FACPs), such as the Flex 400 Series with an  
alarm initiating input signal. Its innovative design, durable  
construction, and multiple mounting options make the  
M46-L Series simple to install, maintain, and operate.  
M46-L Series  
Operation  
Features  
The M46-L manual pull stations provide a textured finger-  
hold area that includes Braille text. In addition, the terms  
PUSH-IN and PULL-DOWN are labeled on the station han-  
dle, and down arrows are engraved to show the direction  
to operate the station handle.  
Compact, aesthetic design, highly visible color,  
attractive contoured shape, and light textured finish.  
Meets with ADA 5 lb. maximum pull force.  
Complies with UL® Standard 38, for manually acuated  
signaling boxes.  
To activate the normally open alarm switch, push-in and  
then pull down on the handle. When the handle is latched  
in the down position, the word “ACTIVATED,” appears in  
bright yellow at the top of the handle.  
To reset the station, do the following:  
1. Insert the key or hex (model dependent).  
2. Twist clockwise, one quarter-turn.  
3. Open the station’s front cover, causing the spring-  
loaded operation handle to return to its original  
position.  
4. To reset the alarm switch to normal (non-alarm),  
manually position or close the station’s front cover.  
The switch is automatically reset.  
Easily operated ( single- or dual-action), yet designed to  
prevent false alarms when bumped, shaken, or jarred.  
Push In/Pull Down handle latches in the down position  
to clearly indicate the station was operated.  
The word, “Activated,” appears in bright yellow on top of  
the handle, indicating the station was operated, and the  
operation of the station  
Operation handle engraved with white, down arrows to  
show the direction to pull the handle.  
Braille text imprinted on the finger-hold area of the oper-  
ation handle and across the top of the handle  
Multiple hex- and key-lock models available  
U.S. patent pending hex-lock needs only a quarter-  
turn to lock/unlock  
Construction  
Station can be opened for inspection & maintenance  
without initiating an alarm  
Product ID label is visible when opening the cover; label  
is made of a durable long-life material  
The terms, “Normal” and “Activated,” are molded into  
the plastic adjacent to the alarm switch( located inside)  
Cover, backplate and operation handle are all molded of  
durable polycarbonate material.  
Cover features white lettering and trim.  
Red color matches System Sensor’s popular  
SpectrAlert® Horn/Strobe Series.  
®
An ISO 9000-2000 Company  
SpectrAlert is a trademark of Honeywell International Inc.  
SIGNALING  
®
UL is a registered trademark of Underwriter’s Laboratories Inc.  
®
Lexan is a registered trademark of GE Plastics, a subsidiary of General Electric  
Company.  
S281  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.  
©2008 by Honeywell International Inc. All rights reserved.  
www.gamewell-fci.com  
CS-2483 Rev. A page 1 of 2  
Engineer’s Specifications  
Features (Continued)  
Manual Fire Alarm Stations shall be non-code, with a key-  
or hex-operated reset lock in order that they may be  
tested, and so designed that after actual emergency oper-  
ation, they cannot be restored to normal except by use of a  
key or hex. An operated station shall automatically condi-  
tion itself so as to be visually detected as activated.  
Four-position terminal strip molded into backplate.  
Terminal strip includes Phillips combination-head cap-  
tive 8/32 screws for easy connection to Initiating Device  
Circuit (IDC).  
Terminal screws backed-out at factory and shipped  
ready to accept field wiring (up to 12 AWG/3.25 mm²).  
Switch contacts are normally open.  
Can be surface-mounted (with SB-I/O) or semi-flush  
mounted. Semi-flush mount to a standard single-gang,  
double-gang, or 4” (10.16 cm) square electrical box.  
Backplate is large enough to overlap a single-gang  
backbox cutout by 1/2” (1.27 cm).  
Manual stations shall be constructed of red colored  
LEXAN® (or polycarbonate equivalent) with clearly visible  
operating instructions provided on the cover. The word,  
FIRE, shall appear on the front of the stations in white let-  
ters, 1.00 inches (2.54 cm) or larger. Stations shall be suit-  
able for the following:  
Optional trim ring (BG-TR).  
surface mounting on matching backbox SB-I/0  
semi-flush mounting on a standard single-gang, double-  
gang, or 4.0” (10.16 cm) square electrical box.  
Models packaged in attractive, clear plastic (PVC),  
clamshell-style, packages. Packaging includes a cut-  
away dust/paint cover in shape of pull station.  
The stations shall be installed in compliance with the  
Americans with Disabilities Act (ADA) or per national and  
local requirements. Manual stations shall be Listed with  
Underwriters’ Laboratories.  
Specifications  
Ordering Information  
Electrical Specifications:  
Switch  
Part Number Description  
M46-SL  
M46-DL  
M46-OL  
Manual pull station, single with key.  
Contact Ratings:  
Gold-plated,  
Manual pull station, dual with key.  
Manual pull station, on door with key, no  
backbox.  
rated 0.25 A @ 30 VAC or VDC.  
Auxiliary  
Contact Circuit:  
(Terminals 3 & 4, NBG-12LA):  
rated to 3.0 @ 30 VAC or VDC.  
M46-OLB  
SB-IO  
Manual pull station, on door with key  
and backbox.  
Surface backbox.  
Physical Specifications:  
Model  
Dimensions  
M46-L  
5.5” H x 4.12” W x 1.4” D  
(13.97 H x 10.47 W x 3.5 D cm)  
5.5” H x 4.3” W x 1.4” D  
(13.97 H x 10.47 W x 3.5 D cm)  
6” H x 4.7” W x 2” D  
SB-10  
WP-10  
(15.24 H x 11.9 W x 5.08 cm)  
GAMEWELL-FCI  
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118  
CS-2483 Rev. A page 2 of 2  
www.gamewell-fci.com  

相关型号:

M46-OLB

Conventional Fire Alarm Pull Stations
GAMEWELL-FCI

M46-SL

Conventional Fire Alarm Pull Stations
GAMEWELL-FCI

M463L0914BT0-CA0

DDR DRAM Module, 8MX64, 0.8ns, CMOS, DIMM-172
SAMSUNG

M463L0914BT0-CA2

DDR DRAM Module, 8MX64, 0.75ns, CMOS, DIMM-172
SAMSUNG

M463L0914BT0-CB0

DDR DRAM Module, 8MX64, 0.75ns, CMOS, DIMM-172
SAMSUNG

M463L0914BT0-LA0

DDR DRAM Module, 8MX64, 0.8ns, CMOS, DIMM-172
SAMSUNG

M463L0914BT0-LA2

DDR DRAM Module, 8MX64, 0.75ns, CMOS, DIMM-172
SAMSUNG

M463L0914BT0-LB0

DDR DRAM Module, 8MX64, 0.75ns, CMOS, DIMM-172
SAMSUNG

M463L0914DT0-CA0

DDR DRAM Module, 8MX64, 0.8ns, CMOS, MICRO, SODIMM-172
SAMSUNG

M463L0914DT0-CA2

DDR DRAM Module, 8MX64, 0.75ns, CMOS, MICRO, SODIMM-172
SAMSUNG

M463L0914DT0-CB0

DDR DRAM Module, 8MX64, 0.75ns, CMOS, MICRO, SODIMM-172
SAMSUNG

M463L0914DT0-CB3

DDR DRAM Module, 8MX64, 0.7ns, CMOS, MICRO, SODIMM-172
SAMSUNG